Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Beam Loss Monitors in the NSLS Storage Rings

Beam loss monitors (BLM) have been used for more than two decades in the VUV ring at the NSLS. These have proved useful for optimizing injection and operation of the ring. Recently similar monitors have been installed in the X-ray ring and are being used to better understand injection, as well as operation of the ring. These units have been compared with the Bergoz BLMs, which have been mostly useful for understanding operating beam losses.

43 PARTICLE ACCELERATORS↗

TH-E-209-02: Dose Monitoring and Protocol Optimization: The Pediatric Perspective

Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

60 APPLIED LIFE SCIENCES↗

Biosensors for Real-Time Monitoring of Radiation-Induced Biologic Effects in Space

This work seeks to develop cellular biosensors based on dendritic polymers. Nanoscale polymer structures less than 20 nm in diameter will be used as the basis of the biosensors. The structures will be designed to target into specific cells of an astronaut and be able to monitor health issues such as exposure to radiation. Multiple components can be assembled on the polymers including target directors, analytical devices (such as molecular probes), and reporting agents. The reporting will be accomplished through fluorescence signal monitoring, with the use of multispectral analysis for signal interpretation. These nanosensors could facilitate the success and increase the safety of extended space flight. The design and assembly of these devices has been pioneered at the Center for Biologic Nanotechnology in the University of Michigan. This period, synthesis of the test-bed biosensors continued. Studies were performed on the candidate fluorescent dyes to determine which might be suitable for the biosensor under development. Development continued on producing an artificial capillary bed as a tool for the use in the production of the fluorescence signal monitor. Work was also done on the in vitro multispectral analysis system, which uses the robotic microscope.

Baker, James R.↗

A Radiation Weather Station: Development of a Continuous Monitoring System for the Collection, Analysis, and Display of Environmental Radiation Data

Due to heightened fear surrounding the possibility of future terrorism involving nuclear weapons and radiological dispersive devices, compounded by nonroutine nuclear power plant releases such as from emergencies or accidents, interest in contamination levels of environmental radiation has spiked. This project sought to develop a continuously operational radiation-monitoring system, with graphically visualized data easily accessible to the public. Because this continuing project is housed at a university facility, it bears no connection to perceived political or commercial interests, generally increasing the credibility of the endeavor. Outdoor weather and radiation parameters were gathered by sensors installed on the rooftop of a two-story building. A display and cloud service website was used to project the live data in an understandable format. A correlation was observed between weather and visibly heightened levels of gamma radiation. Furthermore, the goal of this paper is to share and highlight the overall hardware selection and the unique software challenges encountered when developing a robust collection and analysis system, along with the challenges of displaying meteorological and radiological data in a clear and concise fashion.

07 ISOTOPE AND RADIATION SOURCES↗

Biosensors for Real-Time Monitoring of Radiation-Induced Biologic Effects in Space

This proposal seeks to develop cellular biosensors based on dendritic polymers. Nanoscale polymer structures less than 20 nm in diameter will be used as the basis of the sensor/actuators. The structures will be designed to target into specific cells of an astronaut and be able to monitor health issues such as the exposure to radiation or infectious agents. Multiple components can be assembled on the polymers including target directors, analytical devices (such as molecular probes), magnetic particles and metals, and imaging agents. The design and assembly of these devices has been pioneered at the Center for Biologic Nanotechnology in the University of Michigan. These molecules would also be able to administer therapeutics in response to the needs of the astronaut, and act as actuators to remotely manipulate an astronaut as necessary to ensure their safety. The reporting will be accomplished either through fluorescence signal monitoring, with the use of multispectral analysis for signal interpretation, or through functional MRI. These nanosensors coupled to NEMS devices could facilitate the success and increase the safety of extended space flight.

Baker, James R., Jr.↗

RadWorks Project. ISS REM - to - BIRD - to - HERA: The Evolution of a Technology

The advancement of particle detectors based on technologies developed for use in high-energy physics applications has enabled the development of a completely new generation of compact low-power active dosimeters and area monitors for use in space radiation environments. One such device, the TimePix, is being developed at CERN, and is providing the technology basis for the most recent line of radiation detection devices being developed by the NASA AES RadWorks project. The most fundamental of these devices, an ISS-Radiation Environment Monitor (REM), is installed as a USB device on ISS where it is monitoring the radiation environment on a perpetual basis. The second generation of this TimePix technology, the BIRD (Battery-operated Independent Radiation Detector), was flown on the NASA EFT-1 flight in December 2014. Data collected by BIRD was the first data made available from the Trapped Belt region of the Earth's atmosphere in over 40 years. The 3rdgeneration of this technology, the HERA (Hybrid Electronic Radiation Assessor), is planned to be integrated into the Orion EM-1, and EM-2 vehicles where it will monitor the radiation environment. For the EM-2 flight, HERA will provide Caution and Warning notification for SPEs as well as real time dose measurements for crew members. The development of this line of radiation detectors provide much greater information and characterization of charged particles in the space radiation environment than has been collected in the past, and in the process provide greater information to inform crew members of radiation related risks, while being very power and mass efficient.

McLeod, Catherine D.↗

Application of a phase space beam position and size monitor for synchrotron radiation

We report on a system (ps-BPM) that can measure the electron source vertical position and angular motion along with the vertical source size and angular size at a single location in a synchrotron bend magnet beamline. This system uses a combination of a monochromator and a filter with a K-edge to which the monochromator was tuned in energy. Measurement of the vertical beam location without the absorber and vertical edge location with the absorber allows measurement of the source position and angle. The beam width and edge width give information about the ver-tical electron source size and angular distribution. In this work, we show a typical measurement with the ps-BPM monitor and results that can be obtained from a single measurement. By combining the analysis in the time and frequency domain, information on beam motion and size can be extracted and identified. Examples of ps-BPM applications are given.

Samadi, N.↗

Prompt radiation detectors to monitor target conditions

Lessons learned by basic scientists in the study of experimental nuclear physics can often go unnoticed by cyclotron operator's intent on meeting a demanding schedule of tracer production. Prompt neutrons and gammas are the signature that the desired reaction is occurring, providing a robust measure of the expected yield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Clinical Application of In-Room Positron Emission Tomography for In Vivo Treatment Monitoring in Proton Radiation Therapy

Purpose: The purpose of this study is to evaluate the potential of using in-room positron emission tomography (PET) for treatment verification in proton therapy and for deriving suitable PET scan times. Methods and Materials: Nine patients undergoing passive scattering proton therapy underwent scanning immediately after treatment with an in-room PET scanner. The scanner was positioned next to the treatment head after treatment. The Monte Carlo (MC) method was used to reproduce PET activities for each patient. To assess the proton beam range uncertainty, we designed a novel concept in which the measured PET activity surface distal to the target at the end of range was compared with MC predictions. The repositioning of patients for the PET scan took, on average, approximately 2 minutes. The PET images were reconstructed considering varying scan times to test the scan time dependency of the method. Results: The measured PET images show overall good spatial correlations with MC predictions. Some discrepancies could be attributed to uncertainties in the local elemental composition and biological washout. For 8 patients treated with a single field, the average range differences between PET measurements and computed tomography (CT) image-based MC results were <5 mm (<3 mm for 6 of 8 patients) and root-mean-square deviations were 4 to 11 mm with PET-CT image co-registration errors of approximately 2 mm. Our results also show that a short-length PET scan of 5 minutes can yield results similar to those of a 20-minute PET scan. Conclusions: Our first clinical trials in 9 patients using an in-room PET system demonstrated its potential for in vivo treatment monitoring in proton therapy. For a quantitative range prediction with arbitrary shape of target volume, we suggest using the distal PET activity surface.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-E-209-01: Fluoroscopic Dose Monitoring and Patient Follow-Up Program at Massachusetts General Hospital

Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

60 APPLIED LIFE SCIENCES↗

Short Diffusion Time Diffusion-Weighted Imaging With Oscillating Gradient Preparation as an Early Magnetic Resonance Imaging Biomarker for Radiation Therapy Response Monitoring in Glioblastoma: A Preclinical Feasibility Study

To investigate a novel alternative diffusion-weighted imaging (DWI) approach using oscillating gradients preparation (OGSE) to obtain much shorter effective diffusion times (Δ{sub eff}) for tumor response monitoring by apparent diffusion coefficient (ADC) mapping in a glioblastoma mouse model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emergency Radiation Dose Rate Monitoring During Prolonged Armed Conflict

The 2022 Russian full-scale invasion of Ukraine has introduced unprecedented challenges for the nuclear power generation and radiological safety communities, including occupation and disturbance of highly-contaminated areas, occupation of a nuclear power plant, and strikes near and within boundaries of nuclear sites. The war has necessitated the implementation of a supplementary dose rate sensor network to provide resilient measurement data for public protection and leadership awareness. This paper discusses the implementation of such a system, the factors determining what equipment is best suited for the purpose, and practical factors regarding deployment of the system and data management. The crucial factors for operating a supplementary dose rate sensing network are backup power and communications options for dose rate sensors to make the network resilient to the effects of military operations. The most important implementation factor is to plan for extended operations beyond those typically considered for emergency response given the unpredictable nature of warfare.

resilience↗

Development of Field-Portable CdZnTe (CZT) Radiation Detectors to Monitor and Localize Special Nuclear Materials

For nearly 40 years, CdTe and later CZT have been the room temperature detector of choice for critical applications where traditional scintillators were inadequate and the cost and cooling requirements of germanium were prohibitive. This situation has not changed. At the low end of performance, the detector needs of the vast majority of commercial applications are satisfied with the very low costs scintillators, NaI(Tl) and CsI(Tl). Prices can be as low as a few dollars per cubic centimeter and in sizes up to thousands of cubic centimeters. The availability of these materials stifles the market driven incentive to develop more cost effective production techniques for semiconductor detector materials. Thus, it is unlikely that any semiconductor will replace these materials in the foreseeable future.

36 MATERIALS SCIENCE↗