Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference Electrode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

SU-C-201-03: Ionization Chamber Collection Efficiency in Pulsed Radiation Fields of High Pulse Dose

Purpose: To investigate the reduction of collection efficiency of ionization chambers (IC) by volume recombination and its correction in pulsed fields of very high pulse dose. Methods: Measurements of the collection efficiency of a plane-parallel advanced Markus IC (PTW 34045, 1mm electrode spacing, 300V nominal voltage) were obtained for collection voltages of 100V and 300V by irradiation with a pulsed electron beam (20MeV) of varied pulse dose up to approximately 600mGy (0.8nC liberated charge). A reference measurement was performed with a Faraday cup behind the chamber. It was calibrated for the liberated charge in the IC by a linear fit of IC measurement to reference measurement at low pulse doses. The results were compared to the commonly used two voltage approximation (TVA) and to established theories for volume recombination, with and without considering a fraction of free electrons. In addition, an equation system describing the charge transport and reactions in the chamber was solved numerically. Results: At 100V collection voltage and moderate pulse doses the established theories accurately predict the observed collection efficiency, but at extreme pulse doses a fraction of free electrons needs to be considered. At 300V the observed collection efficiency deviates distinctly from that predicted by any of the established theories, even at low pulse doses. However, the numeric solution of the equation system is able to reproduce the measured collection efficiency across the entire dose range of both voltages with a single set of parameters. Conclusion: At high electric fields (3000V/cm here) the existing theoretical descriptions of collection efficiency, including the TVA, are inadequate to predict pulse dose dependency. Even at low pulse doses they might underestimate collection efficiency. The presented, more accurate numeric solution, which considers additional effects like electric shielding by the charges, might provide a valuable tool for future investigations. This project was funded by the German ministry of research and education (BMBF) under grant number: 03Z1N511 and by the state of Saxony under grant number: B 209.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of possible lower hybrid emission from the NASA Lewis bumpy torus plasma

Radio frequency emission has been detected near the power hybrid frequency of a bumpy torus plasma by using a responsive detection system that consists of a spectrum analyzer and a 50 ohm miniature coaxial antenna concentrically located in a re-entrant quartz tube. The frequency shift of a broad emission peak was monitored as a function of background pressure, electrode voltage, and the strength of the dc magnetic field. Simultaneous measurements of the average plasma density were made with a polarization diplexing microwave interferometer. The information derived from the experiment is discussed with particular reference to the following: (1) whether the emissions are dominated by atomic or molecular species of deuterium; (2) the strength of the dc magnetic field in the emitting region; (3) the geometric location of the emitting region of the plasma; (4) comparison of the lower hybrid plasma density with the average plasma density; and (5) relation of ion spoke geometry to lower hybrid emission.

Mallavarpu, R.↗

Lower hybrid emission diagnostics on the NASA Lewis bumpy torus

The feasibility of using RF emission near the lower hybrid frequency of the NASA Lewis Bumpy Torus plasma for diagnostic purposes is examined. The emission is detected using a spectrum analyzer and a 50 omega miniature coaxial antenna that is sensitive to the polarization of the incoming signal. The frequency shift of the lower hybrid emission peak is monitored as a function of the background pressure, electrode voltage, electrode ring configuration and the strength of the toroidal dc magnetic field. Simultaneous measurements of the average plasma density are made with a polarization diplexing microwave interferometer. Data derived from the experiment are discussed with reference to the following: (1) the strength of the dc magnetic field in the emitting region; (2) comparison of the lower hybrid plasma density with the average plasma density; and (3) validity of the cold plasma lower hybrid resonance formula in the high density operating regime of the bumpy torus plasma.

Mallavarpu, R.↗

Direct conversion of light to radio frequency energy

A description is presented of the test results obtained with the latest models of the phototron. The phototron was conceived as a replacement for the high voltage solar cell-high power klystron combination for the solar power satellite concept. Physically, the phototron is a cylindrical evacuated glass tube with a photocathode, two grids, and a reflector electrode in a planar configuration. The phototron can be operated either in a biased mode where a low voltage is used to accelerate the electron beam produced by the photocathode or in an unbiased mode referred to as self-oscillation. The device is easily modulated by light input or voltage to broadcast in AM or FM. The range of operation of the present test model phototrons is from 2 to 200 MHz.

Freeman, J. W.↗

Chemical Evolution in Silicon–Graphite Composite Anodes Investigated by Vibrational Spectroscopy

Silicon–graphite composites are under development for the next generation of high-capacity lithium-ion anodes, and vibrational spectroscopy is a powerful tool to identify the different mechanisms that contribute to performance loss. With alloy anodes, the underlying causes of cell failure are significantly different in half-cells with lithium metal counter electrodes compared to full cells with standard cathodes. However, most studies which take advantage of vibrational spectroscopy have only examined half-cells. In this work, a combination of FTIR and Raman spectroscopy describes several factors that lead to degradation in full pouch cells with LiNi 0.5 Mn 0.3 Co 0.2 O 2 (NMC532) cathodes. The spectroscopic signatures evolve after longer term cycling compared to the initial formation cycles. Several side-reactions that consume lithium ions have clear FTIR signatures, and comparison to a library of reference compounds facilitates identification. Raman microspectroscopy combined with mapping shows that the composite anodes are not homogeneous but segregate into graphite-rich and silicon-rich phases. Lithiation does not proceed uniformly either. A basis analysis of Raman maps identifies electrochemically inactive regions of the anodes. In conclusion, the spectroscopic results presented here emphasize the importance of improving electrode processing and SEI stability to enable practical composite anodes with high silicon loadings.

25 ENERGY STORAGE↗

Evaluation of phenolic antioxidant capacity in beverages based on laccase immobilized on screen-printed carbon electrode modified with graphene nanoplatelets and gold nanoparticles

A simple and highly sensitive electrochemical biosensor based on laccase immobilized onto a gold nanoparticles/graphene nanoplatelets-modified screen-printed carbon electrode (LACC/AuNP/GNPl/SPCE) was developed for the determination of hydroquinone (HQ) and other phenolic compounds. The biosensor shows excellent electro-catalytic activity towards oxidation of hydroquinone at a potential of -0.05 V (vs Ag/AgCl, 3 M KCl) in phosphate buffer as supporting electrolyte (0.1 M, pH 7.0) using hydrodynamic amperometry. Analytical characteristics uncover that the LACC/AuNP/GNPl/SPCE comprises a wide linear range for the dependence of the signal on HQ concentrations from 4 to 130 µM with a detection limit (3σ) of 1.5 µM. The repeatability (5 measurements, 100 µM hydroquinone) is ±2% and the reproducibility (5 biosensors, 100 µM hydroquinone) is ±3%. Interference studies of most common compounds with the determination of hydroquinone demonstrated negligible effects. Finally, the biosensor and the analytical method were applied to the determination of phenolic antioxidant capacity (AOC) in wine and blueberry syrup based on Trolox (6‑hydroxy‑2,5,7,8-tetramethylchromane-2-carboxylic acid) and hydroquinone equivalents. The results were evaluated by using their calibration curves which were satisfactory and agreed well with the results obtained by the reference method Trolox Equivalent Antioxidant Capacity assay (TEAC-Assay).

60 APPLIED LIFE SCIENCES↗

Investigation of vertical GaN-on-GaN p – n diode with regrown p -GaN for operation in Venus and other extreme environments

This Letter reports the performance of vertical GaN-on-GaN p–n diodes with etch-then-regrown p-GaN after exposure to a simulated Venus environment (460 °C, ∼94 bar, containing CO2/N2/SO2 etc., atmosphere) for over 10 days, and compared them to the performance of GaN p–n diodes without the etch-then-regrow process. After the above-mentioned Venus test, temperature-dependent I–V and microscopy investigation were conducted to study the robustness of etch-then-regrow p-GaN and vertical GaN p–n diodes under harsh environments and operation up to 500 °C. p-electrode degradation is found to be the main issue of the device's performance. This is the highest temperature at which such characterization has been conducted for vertical GaN p–n diodes, therefore establishing a critical reference for the development of p-GaN regrown and vertical GaN-based electronics for extreme environments.

Physics↗

Effective point of measurement of thimble ion chambers in megavoltage photon beams

Purpose: Determine the effective point of measurement (EPOM) of 12 thimble ion chambers, including miniature chambers and three models widely used for clinical reference dosimetry. The EPOM is the point at which the measured dose would arise in the measurement medium in the absence of the probe: For cylindrical chambers, it is shifted upstream relative to the central axis of the chamber. Although current dosimetry protocols prescribe a blanket upstream EPOM shift of 0.6r, with r as the chamber cavity radius, it has been shown in recent years that the EPOM does, in fact, depend on every detail of the chamber design and on the beam characteristics. In the wake of this finding, the authors undertake a comprehensive study of the EPOM for a series of chambers in water. Methods: This work relies on EGSnrc Monte Carlo calculations for the central axis depth dose in a water phantom and in ion chambers. They use a full Elekta Precise linac treatment head simulation to generate realistic photon beams with nominal energies of 6 and 25 MV and fields sizes of 10x10 and 40x40 cm{sup 2}. The correct EPOM shift for the 12 ion chambers, modeled in realistic detail, is taken as the one minimizing the deviation of the ratio between the dose to water and the dose to the gas of the chamber cavity, according to a method proposed and validated in previous work. Results: The analysis reveals that the actual EPOM shift is significantly smaller than the recommended value in current dosimetry protocols, by up to 25% for reference-class chambers and 80% for miniature chambers. The location of the EPOM also depends on the characteristics of the incident beam and varies in a well-defined way with the cavity length, the central electrode radius, and the thimble wall thickness. Conclusions: The authors confirm that an upstream EPOM shift of 0.6r is too large for thimble ion chambers in high energy photon beams. Proper values for the EPOM shift could be tabulated per beam and per chamber, but they envisage that a single shift for all practical beams may prove sufficient. Moreover, the systematic dependence on chamber characteristics provides evidence that a universal parametrization in terms of a few design parameters is conceivable and has implication for the calculation of chamber correction factors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Standard Electrode Potentials Involving Radicals in Aqueous Solution: Inorganic Radicals

Recommendations are made for standard potentials involving select inorganic radicals in aqueous solution at 25 °C. These recommendations are based on a critical and thorough literature review and also by performing derivations from various literature reports. The recommended data are summarized in tables of standard potentials, Gibbs energies of formation, radical pK a ’s, and hemicolligation equilibrium constants. In all cases, current best estimates of the uncertainties are provided. An extensive set of Data Sheets is appended that provide original literature references, summarize the experimental results, and describe the decisions and procedures leading to each of the recommendations

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Field Effect in a Metal–Ferroelectric–Semiconductor System of Multilayer Ferroelectric Films with Various Structure Types

The ability to grow the interfacial defect-poor Sr{sub 0.5}Ba{sub 0.5}Nb{sub 2}O{sub 6} + Ba{sub 0.2}Sr{sub 0.8}TiO{sub 3} and Ba{sub 0.8}Sr{sub 0.2}TiO{sub 3} + Ba{sub 0.4}Sr{sub 0.6}TiO{sub 3} ferroelectric films onto the doped silicon substrates is discussed. A study of piezo-response via the quasi-static method (using the electrode area of 0.07 mm{sup 2}) reveals that heterostructures possess an initial polarized ferroelectric state with a spontaneous polarization vector perpendicular to the substrate at any type of Si conductivity. The polarized state is established to refer to two-dimension stresses in the ferroelectric, which is tunable through a preprepared Ba{sub x}Sr{sub 1–x}TiO{sub 3} onto a sublayer substrate as well as to a thickness of this sublayer. Polarization switching in Sr{sub 0.5}Ba{sub 0.5}Nb{sub 2}O{sub 6}/Si and Ba{sub 0.8}Sr{sub 0.2}TiO{sub 3}/Si heterostructures under the external field arises at only using the barium–strontium titanate sublayer predeposited onto silicon. A 15% decrease in switching polarization in Ba{sub 0.8}Sr{sub 0.2}TiO{sub 3}/Ba{sub 0.4}Sr{sub 0.6}TiO{sub 3}/Si structures is observed after 500 h.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electrochemical Modeling and Experimental Verification of Lithiation Gradients in Oxide Cathodes of Lithium-Ion Cells

Lithiated nickel-cobalt-manganese oxides, such as NCM523, are used in the positive electrode (cathode) of Li-ion cells. Using operando X-ray diffraction profilometry, lithiation gradients in the cathode matrix can be observed and quantified by expansion into Legendre polynomials with time-dependent weights. These weights (referred to as gradients) increase in magnitude when electric current flows through the cell, decrease during potentiostatic hold and finally relax to zero when the current is interrupted during open circuit rest. Both physics-based electrochemical models and operando X-ray experiments suggest that the time constants for gradient growth and abatement are primarily determined by ionic diffusion in the oxide particles, which in turn depends on their lithium content. In contrast, the magnitude of gradients depends mainly on the applied current. The X-ray profilometry provides a way of directly probing the formation and disappearance of Li gradients across the cathode during fast cycling, which can help to diagnose the effects of material degradation in the cells.

25 ENERGY STORAGE↗

Overview of the High Performance Antiproton (HiPAT) Experiment

The annihilation of matter with antimatter represents the highest energy density of any known reaction, producing 10(exp 8) MJ/g, approximately 10 orders of magnitude more energy per unit mass than chemical based combustion. To take the first step towards using this energy for propulsion applications the NASA MSFC Propulsion Research Center (PRC) has initiated a research activity examining the storage of low energy antiprotons. Storage was identified as a key enabling technology since it builds the experience base necessary to understand the handling of antiprotons for virtually all utilization and high-density storage concepts. To address this need, a device referred to as the High Performance Antiproton Trap (HiPAT) is under development at the NASA MSFC PRC. The HiPAT is an electromagnetic system (Penning-Malmberg design) consisting of a 4 Tesla superconductor, a high voltage confinement electrode system (operation up to 20 KV), and an ultra high vacuum test section (operating in the 10(exp -12) torr range). The system was designed to be portable with an ultimate goal of maintaining 10(exp 12) charged particles with a half-life of 18 days. Currently, this system is being experimentally evaluated using normal matter ions which are cheap to produce and relatively easy to handle. These normal ions provide a good indication of overall trap behavior, with the exception of assessing annihilation losses. The ions are produced external to HiPAT using two hydrogen ion sources, with adjustable beam energy and current. Ion are transported in a beam line and controlled through the use of electrostatic optics. These optics serve to both focus and gate the incoming ions, providing microsecond-timed pulses that are dynamically captured by cycling the HiPAT electric containment field like a 'trap door'. The layout of this system more closely simulates the operations expected at an actual antiproton production facility where 'packets' of antiprotons with pulse widths measured in 100's of nanoseconds could be provided. Initial dynamic capture experiments have been performed with both trap and ton source system functioning at approximately 10% of maximum levels, minimizing the potential for extraneous effects. Dynamic trapping techniques demonstrated the successful capture of millions of hydrogen ions with good agreement with the predicted loading based on the timing sequence, trap electric field, and ion beam current. These techniques will be expanded to examine multiple shot capture or 'stacking' to increase the total number of ions stored within HiPAT.

Martin, James J.↗

Process Optimization of Carbon Electrode Materials Manufacturing by Experimental Study and Machine Learning Techniques

Electrospun carbon fibers from coal have been investigated as electrodes for batteries and supercapacitors. Despite the excellent properties of coal-derived carbon fibers (CCNF) for energy storage devices, there still lacks systematic understanding on how various process parameters affect final electrode performances, which poses challenges to scale from pilot to high volume manufacturing. The goals of this project are twofold. First, we focuse on process optimization for converting a new precursor from powder river basin (PRB) coal, referred to as coal-based polyurethane (CPU) to CCNF using electrospinning. Second, different machine learning techniques will be examined using experimental data from this work and open literature. Specifically, for CPU the following process parameters need to be characterized and optimized in order to produce CCNFs with desirable mechanical integrity and physiochemical properties: precursor composition and viscosity, operating voltage and distance, oxidation and carbonization temperature and duration. Consequently, physiochemical properties of the fibers were characterized to correlate these process parameters with desirable electrochemical performance. Given the complex nature of the fiber production process, ML models are assessed for their ability to capture the nonlinear relationship between process parameters and the electrochemical properties in applications including supercapacitors. As such, we applied various machine learning techniques, to determine which technique produces a model that best predicts device function.

Cincotta, Robert E.F.↗

Characterization of Nano-Crystalline Diamond like Carbon (DLC) Films with Substrate Temperature Using Dense Plasma Focusing Method

Nano-crystalline Diamond like Carbon (DLC) film has been grown by Dense Plasma Focusing Method (DPF) using pure graphite Plasma, on different substrate (glass/silica) at different substrate temperature. The films were grown at substrate temperature 100 deg. C, 150 deg. C and 300 deg. C by the high dense plasma of energy 1.3 k Joule on glass and silica. Raman spectra confirmed that sp{sup 3} content is grown in the films under various conditions. The Raman spectra of these films show a broad asymmetric peak which narrow with sp{sup 2} decreasing contents. We believe that our data presented here may be used as reference of DLC characterization.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Dielectrophoresis-based particle sensor using nanoelectrode arrays

A method for concentrating or partly separating particles of a selected species from a liquid or fluid containing these particles and flowing in a channel, and for determining if the selected species particle is present in the liquid or fluid. A time varying electrical field E, having a root-mean-square intensity E.sup.2.sub.rms with a non-zero gradient in a direction transverse to the liquid or fluid flow direction, is produced by a nanostructure electrode array, with a very high magnitude gradient near exposed electrode tips. A dielectrophoresis force causes the selected particles to accumulate near the electrode tips, if the medium and selected particles have substantially different dielectric constants. An insulating material surrounds most of each of the nanostructure electrodes, and a region of the insulating material surface is functionalized to promote attachment of the selected species particles to the surface. An electrical property value Z(meas) is measured at the functionalized surface and is compared with a reference value Z(ref) to determine if the selected species particles are attached to the functionalized surface.

Li, Jun↗

Highly skewed current–phase relation in superconductor–topological insulator–superconductor Josephson junctions

Three-dimensional topological insulators (TIs) in proximity with superconductors are expected to exhibit exotic phenomena, such as topological superconductivity (TSC) and Majorana-bound states (MBS), which may have applications in topological quantum computation. In superconductor–TI–superconductor Josephson junctions, the supercurrent versus the phase difference between the superconductors, referred to as the current–phase relation (CPR), reveals important information including the nature of the superconducting transport. Here, we study the induced superconductivity in gate-tunable Josephson junctions (JJs) made from topological insulator BiSbTeSe 2 with superconducting Nb electrodes. We observe highly skewed (non-sinusoidal) CPR in these junctions. The critical current, or the magnitude of the CPR, increases with decreasing temperature down to the lowest accessible temperature ( T ~ 20 mK), revealing the existence of low-energy modes in our junctions. The gate dependence shows that close to the Dirac point the CPR becomes less skewed, indicating the transport is more diffusive, most likely due to the presence of electron/hole puddles and charge inhomogeneity. Our experiments provide strong evidence that superconductivity is induced in the highly ballistic topological surface states (TSS) in our gate-tunable TI-based JJs. Furthermore, the measured CPR is in good agreement with the prediction of a model which calculates the phase-dependent eigenstate energies in our system, considering the finite width of the electrodes, as well as the TSS wave functions extending over the entire circumference of the TI.

36 MATERIALS SCIENCE↗

Synthetic battery cycling techniques

Synthetic battery cycling makes use of the fast growing capability of computer graphics to illustrate some of the basic characteristics of operation of individual electrodes within an operating electrochemical cell. It can also simulate the operation of an entire string of cells that are used as the energy storage subsystem of a power system. The group of techniques that as a class have been referred to as Synthetic Battery Cycling is developed in part to try to bridge the gap of understanding that exists between single cell characteristics and battery system behavior.

Leibecki, H. F.↗

Stacking Multiple Ion Captures in The High Performance Antiproton Trap (HiPAT)

The High performance Antiproton Trap (HiPAT) research project was initiated by the Marshall Space Flight Center's propulsion Research Center to examining the fundamental behavior of low energy antiprotons. Stored antiproton would ultimately be used for experimental demonstration of basic propulsive concepts. Matter-antimatter annihilation produces approximately 10(exp 8) MJ/g nearly 10 orders of magnitude more energy per unit mass than chemical based combustion, hence NASA's interest. To achieve containment, HiPAT utilizes a type of electromagnetic bottle know as a Penning trap positioned within an ultrahigh vacuum test section. Recently, the HiPAT hardware configuration has been enhanced to facilitate the capture of multiple normal matter ion burst. This endeavor is often referred to as "stacking" and used to increasing the number of captured particles. A prior normal matter experimental effort, successfully demonstrated the effectiveness of single burst capture. The stacking process is accomplished by manipulating the electric field generated by the confinement electrodes i.e. adjusting the well potential depth. These potential well values are initially configured to maximize the quantity of captured ions per burst; shallow wells with a depth of 100 volt or less (referenced to the incoming ion beam energy) are typically selected. Once captured, a cooling interval is required to reduce the energy of trapped particles below the lower extent of the "trap door" (or leading electrode) ion emitting potential. This is necessary such that a new burst of hot ions can be introduced while preventing those already inside from escaping. The cooling time is driven by a combination of mechanisms such as synchrotron radiation, background gas scattering, and resistive damping in a time scale on the order of minutes. A potential for reducing this hold period is to actively manipulate the electric field shape, using the power supply control system, to produce a deeper potential well. The trapped ions ride down the morphing well to a lower potential energy, leaving margin to once again cycle the "trap door" capturing a new burst while limiting the number of escaping ions. By adjusting the magnitude and timing of the potential well shaping, subsequent shots from the ion beam can be captured on a time scale shorter then that dictated by the standard inject, capture and cool technique. Currently, experimental tests are under way examining the functionally of this system for stacking multiple ions bursts within the HiPAT system.