Tachyons in general relativity

We consider the motion of tachyons (faster-than-light particles) in the framework of general relativity. An important feature is the large contribution of low energy tachyons to the energy-momentum tensor. We also calculate the gravitational field produced by tachyons in particular geometric arrangements; and it appears that there could be self-cohering bundles of such matter. This leads us to suggest that such theoretical ideas might be relevant to major problems (dark matter and dark energy) in current cosmological models.

79 ASTRONOMY AND ASTROPHYSICS↗

Motion of test bodies in theories with nonminimal coupling

We derive the equations of motion of test bodies for a theory with nonminimal coupling by means of a multipole method. The propagation equations for pole-dipole particles are worked out for a gravity theory with a very general coupling between the curvature scalar and the matter fields. Our results allow for a systematic comparison with the equations of motion of general relativity and other gravity theories.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Temperature-jump solution X-ray scattering reveals distinct motions in a dynamic enzyme

Correlated motions of proteins are critical to function, but these features are difficult to resolve using traditional structure determination techniques. Time-resolved X-ray methods hold promise for addressing this challenge, but have relied on the exploitation of exotic protein photoactivity, and are therefore not generalizable. Temperature jumps, through thermal excitation of the solvent, have been utilized to study protein dynamics using spectroscopic techniques, but their implementation in X-ray scattering experiments has been limited. Here, we perform temperature-jump small- and wide-angle X-ray scattering measurements on a dynamic enzyme, cyclophilin A, demonstrating that these experiments are able to capture functional intramolecular protein dynamics on the microsecond timescale. We show that cyclophilin A displays rich dynamics following a temperature jump, and use the resulting time-resolved signal to assess the kinetics of conformational changes. Furthermore, two relaxation processes are resolved: a fast process is related to surface loop motions, and a slower process is related to motions in the core of the protein that are critical for catalytic turnover.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PRACTICAL SOLUTIONS FOR NONLINEAR ACCELERATOR LATTICE WITH STABLE NEARLY REGULAR MOTION

The use of nonlinear lattices with the large betaron tune spreads can increase instablity and space charge thresholds by orders of magnitude compared to typical linear accelarator lattices. Unfortunately, strong nonlinear fields create, in general, strong resonances and chaotic motion. This shrinks the dynamic aperture to impractical values, thus erasing all benefits from their use. Previously known examples of stable and regular accelerator motion with special nonlinear lenses were related to one dimensional motion or round beams. However, no solution has been realized with real 2D tranverse magnetic fields to produce stable, close to regular 2D motion with the large dynamic aperture and betatron tune spread comparable to the betatron tune itself. This paper presents possible solutions for such 2D lattices. They consist of straight sections with short linear and nonlinear lenses with transverse magnetic fields.

Danilov, Viatcheslav V↗

SU-E-T-538: Does Abdominal Compression Through Prone Patient Position Reduce Respiratory Motion in Lung Cancer Radiotherapy?

Purpose: This study assesses the effect of physiological abdominal compression from prone positioning by comparing respiratory-induced tumor movements in supine and prone positions. Methods: 19 lung cancer patients underwent repeated supine and prone free-breathing 4DCT scans. The effect of patient position on motion magnitude was investigated for tumors, lymph nodes (9 cases), and subgroups of central (11 cases), peripheral (8 cases) and small peripheral tumors (5 cases), by evaluating the population average excursions, absolute and relative to a carina-point. Results: Absolute motion analysis: In prone, motion increased by ~20% for tumors and ~25% for lymph nodes. Central tumors moved more compared to peripheral tumors in both supine and prone (~22%, and ~4% respectively). Central tumors movement increased by ~12% in prone. For peripheral tumors the increase in prone position was ~25% (~40% and 29% changes on along RL and AP directions). Motion relative to carina-point analysis: Overall, tumor excursions relative to carina-point increased by ~17% in prone. Lymph node relative magnitudes were lower by ~4%. Likewise, the central tumors moved ~7% less in prone. The subgroup of peripheral tumors exhibited increased amplitudes by ~44%; the small peripheral tumors had even larger relative displacements in prone (~46%). Conclusion: Tumor and lymph node movement in the patient population from this study averaged to be higher in prone than in supine position. Results from carina analysis also suggest that peripheral tissues have more physiologic freedom of motility when placed in the prone position, regardless of size. From these observations we should continue to avoid prone positioning for all types of primary lung tumor, suggesting that patients should receive radiotherapy for primary lung cancer in supine position to minimize target tissue mobility during normal respiratory effort. Further investigation will include more patients with peripheral tumors to validate our observations.

60 APPLIED LIFE SCIENCES↗

Seismoacoustic analysis of underground explosions using the Rayleigh integral

SUMMARY A coupled seismoacoustic model is developed for the analysis of acoustic signals produced by underground explosive events with an aim to develop a means of improving estimated depth and yield for explosion monitoring. A ground spall model is used to predict surface motion characteristics produced by an underground explosion and the Rayleigh integral is applied to relate the surface motion to the acoustic signal some distance from surface ground zero. The low-frequency component of the ground motion associated with the prolonged free fall of lofted material during spall is found to dominate the acoustic signal propagating away from surface ground zero at shallow angles. The model is applied to observed ground motion and acoustic signals recorded during the Source Physics Experiment (SPE) with promising results. In addition to accurately predicting characteristics of the observed acoustic signals from several of the SPE events, the model provides a means of explaining the lack of signals observed during several events in the SPE due to the directionality of the higher frequency acoustic signals associated with the uplift and closure components as well as the lack of a spatially localized, longer duration dwell.

58 GEOSCIENCES↗

Motion Of Bodies And Its Stability In The General Relativity Theory

This paper reviews the works by the Belarusian school investigators on relativistic motion and its stability for a system of bodies, each of which may have its own rotation, charge, and magnetic field of the dipole type. The corresponding Lagrangian and conservation laws are derived, several secular effects are predicted. For motion of bodies in the medium the secular effect of the periastron reverse shift is predicted as compared to the Mercury perihelion shift. The cause for the Pioneer anomaly is explained.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Joint Probability Density–Based Decomposition of Turbulence in the Atmospheric Boundary Layer

Abstract In convective flows, vertical turbulent fluxes, covariances between vertical velocity and scalar thermodynamic variables, include contributions from local mixing and large-scale coherent motions, such as updrafts and downdrafts. The relative contribution of these motions to the covariance is important in turbulence parameterizations. However, the flux partition is challenging, especially in regions without convective cloud. A method to decompose the vertical flux based on the corresponding joint probability density function (JPD) is introduced. The JPD-based method partitions the full JPD into a joint Gaussian part and the complement, which represent the local mixing and the large-scale coherent motions, respectively. The coherent part can be further divided into updraft and downdraft parts based on the sign of vertical velocity. The flow decomposition is independent of water condensate (cloud) and can be applied in cloud-free convection, the subcloud layer, and stratiform cloud regions. The method is applied to large-eddy simulation model data of three boundary layers. The results are compared with traditional cloud and cloud-core decompositions and a decaying scalar conditional sampling method. The JPD-based method includes a single free parameter and sensitivity tests show weak dependence on the parameter values. The results of the JPD-based method are somewhat similar to the cloud-core and conditional sampling methods. However, differences in the relative magnitude of the flux decomposition terms suggest that an objective definition of the flow regions is subtle and diagnosed flow properties like updraft characteristics depend on the sampling method. Moreover, the flux decomposition depends on the thermodynamic variable and convection characteristics.

Chinita, Maria J.↗

Orbital Motion, Variability, and Masses in the T Tauri Triple System

We present results from adaptive optics imaging of the T Tauri triple system obtained at the Keck and Gemini Observatories in 2015−2019. We fit the orbital motion of T Tau Sb relative to Sa and model the astrometric motion of their center of mass relative to T Tau N. Using the distance measured by Gaia, we derived dynamical masses of M{sub Sa}=2.05±0.14 M {sub ⊙} and M {sub Sb} = 0.43 ± 0.06 M{sub ⊙}. The precision in the masses is expected to improve with continued observations that map the motion through a complete orbital period; this is particularly important as the system approaches periastron passage in 2023. Based on published properties and recent evolutionary tracks, we estimate a mass of ∼2 M {sub ⊙} for T Tau N, suggesting that T Tau N is similar in mass to T Tau Sa. Narrowband infrared photometry shows that T Tau N remained relatively constant between late 2017 and early 2019 with an average value of K = 5.54 ± 0.07 mag. Using T Tau N to calibrate relative flux measurements since 2015, we found that T Tau Sa varied dramatically between 7.0 and 8.8 mag in the K band over timescales of a few months, while T Tau Sb faded steadily from 8.5 to 11.1 mag in the K band. Over the 27 yr orbital period of the T Tau S binary, both components have shown 3–4 mag of variability in the K band, relative to T Tau N.

79 ASTRONOMY AND ASTROPHYSICS↗

Note: Reliable and non-contact 6D motion tracking system based on 2D laser scanners for cargo transportation

Maritime transportation demands an accurate measurement system to track the motion of oscillating container boxes in real time. However, it is a challenge to design a sensor system that can provide both reliable and non-contact methods of 6-DOF motion measurements of a remote object for outdoor applications. In the paper, a sensor system based on two 2D laser scanners is proposed for detecting the relative 6-DOF motion of a crane load in real time. Even without implementing a camera, the proposed system can detect the motion of a remote object using four laser beam points. Because it is a laser-based sensor, the system is expected to be highly robust to sea weather conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Shallow Soil Response to a Buried Chemical Explosion With Geophones and Distributed Acoustic Sensing

Abstract Shallow sediments can respond non‐linearly to large dynamic strains and undergo a subsequent healing phase as the material gradually recovers following the passing of seismic waves. This study focuses on the physical changes in the subsurface caused by the shaking from a buried chemical explosion detonated in a borehole in Nevada, USA, as a part of the Source Physics Experiment Phase II. The explosion damaged the shallow subsurface and modified the frequency content recorded by 491 geophones and 2240 Distributed Acoustic Sensing (DAS) channels within 2.5 km from surface ground zero. We observe a gradual shift of resonance frequencies in the 10–25 Hz frequency band in the hours following the explosion and develop a method to characterize the related logarithm‐type healing process of the shallow (i.e., upper ∼25 m) subsurface. We find that stronger levels of ground motion increase the relative degree of damage and duration of the subsurface healing; with the spall region exhibiting the largest degree of damage and longest healing recovery time. We observe coherent spatial patterns of damage with the region located to the southeast of the explosion exhibiting more damage than the southwest region. This study demonstrates that both DAS and co‐located geophones capture similar temporal changes associated with the physical processes occurring in the subsurface, with the high‐density sampling of DAS measurements enabling a new capability to monitor the fine‐scale changes of the Earth's shallow subsurface following the detonation of a buried explosion.

Viens, Loïc↗

Proper Motions and Structural Parameters of the Galactic Globular Cluster M71

By exploiting two ACS/ HST data sets separated by a temporal baseline of ∼7 years, we have determined the relative stellar proper motions (PMs; providing membership) and the absolute PM of the Galactic globular cluster M71. The absolute PM has been used to reconstruct the cluster orbit within a Galactic, three-component, axisymmetric potential. M71 turns out to be in a low-latitude disk-like orbit inside the Galactic disk, further supporting the scenario in which it lost a significant fraction of its initial mass. Since large differential reddening is known to affect this system, we took advantage of near-infrared, ground-based observations to re-determine the cluster center and density profile from direct star counts. The new structural parameters turn out to be significantly different from the ones quoted in the literature. In particular, M71 has a core and a half-mass radii almost 50% larger than previously thought. Finally, we estimate that the initial mass of M71 was likely one order of magnitude larger than its current value, thus helping to solve the discrepancy with the observed number of X-ray sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Dynamics of a vertical flight in the stationary gravitational field of a celestial body: Post-newtonian corrections and gravitational redshift

The standard problem of a radial motion of test particles in the stationary gravitational field of a spherically symmetric celestial body is solved and is used to determine the time features of this motion. The problem is solved for the equations of motion of general relativity (GR), and the time features are obtained in the post-Newtonian approximation, with linear GR corrections proportional to r{sub g}/r and {beta}{sup 2} (in the solution being considered, they are of the same order of smallness) being taken rigorously into account. Total times obtained by integrating the time differentials along the trajectories of motion are considered as the time features in question. It is shown that, for any parameters of the motion, the proper time (which corresponds to watches comoving with a test particle) exceeds the time of watches at rest (watches at the surface of the celestial body being considered). The mass and the radius of the celestial body, as well as the initial velocity of the test particle, serve as arbitrary parameters of the motion. The time difference indicated above implies a leading role of the gravitational redshift, which decreases somewhat because of the opposite effect of the Doppler shift. The results are estimated quantitatively for the important (from the experimental point of view) case of vertical flights of rockets starting from the Earth's surface. In this case, the GR corrections, albeit being extremely small (a few microseconds for several hours of the flight), aremeasurable with atomic (quantum) watches.

79 ASTRONOMY AND ASTROPHYSICS↗

Candidate gravitational microlensing events for future direct lens imaging

The mass of the lenses giving rise to Galactic microlensing events can be constrained by measuring the relative lens-source proper motion and lens flux. The flux of the lens can be separated from that of the source, companions to the source, and unrelated nearby stars with high-resolution images taken when the lens and source are spatially resolved. For typical ground-based adaptive optics (AO) or space-based observations, this requires either inordinately long time baselines or high relative proper motions. We provide a list of microlensing events toward the Galactic bulge with high relative lens-source proper motion that are therefore good candidates for constraining the lens mass with future high-resolution imaging. We investigate all events from 2004 to 2013 that display detectable finite-source effects, a feature that allows us to measure the proper motion. In total, we present 20 events with μ ≳ 8 mas yr{sup –1}. Of these, 14 were culled from previous analyses while 6 are new, including OGLE-2004-BLG-368, MOA-2005-BLG-36, OGLE-2012-BLG-0211, OGLE-2012-BLG-0456, MOA-2012-BLG-532, and MOA-2013-BLG-029. In ≲12 yr from the time of each event the lens and source of each event will be sufficiently separated for ground-based telescopes with AO systems or space telescopes to resolve each component and further characterize the lens system. Furthermore, for the most recent events, comparison of the lens flux estimates from images taken immediately to those estimated from images taken when the lens and source are resolved can be used to empirically check the robustness of the single-epoch method currently being used to estimate lens masses for many events.

79 ASTRONOMY AND ASTROPHYSICS↗

A Topological Approach for Motion Track Discrimination

Detecting small targets at range is difficult because there is not enough spatial information present in an image sub-region containing the target to use correlation-based methods to differentiate it from dynamic confusers present in the scene. Moreover, this lack of spatial information also disqualifies the use of most state-of-the-art deep learning image-based classifiers. Here, we use characteristics of target tracks extracted from video sequences as data from which to derive distinguishing topological features that help robustly differentiate targets of interest from confusers. In particular, we calculate persistent homology from time-delayed embeddings of dynamic statistics calculated from motion tracks extracted from a wide field-of-view video stream. In short, we use topological methods to extract features related to target motion dynamics that are useful for classification and disambiguation and show that small targets can be detected at range with high probability.

Emerson, Tegan H.↗

Modulation of hemoglobin dynamics by an allosteric effector

Hemoglobin (Hb) is an extensively studied paradigm of proteins that alter their function in response to allosteric effectors. Models of its action have been used as prototypes for structure-function relationships in many proteins, and models for the molecular basis of its function have been deeply studied and extensively argued. Recent reports suggest that dynamics may play an important role in its function. Relatively little is known about the slow, correlated motions of hemoglobin subunits in various structural states because experimental and computational strategies for their characterization are challenging. Allosteric effectors such as inositol hexaphosphate (IHP) bind to both deoxy-Hb and HbCO, albeit at different sites, leading to a lowered oxygen affinity. The manner in which these effectors impact oxygen binding is unclear and may involve changes in structure, dynamics or both. Here we use neutron spin echo (NSE) measurements accompanied by wideangle x-ray scattering (WAXS) to show that binding of IHP to HbCO results in an increase in the rate of coordinated motions of Hb subunits relative to one another with little if any change in large scale structure. This increase of large-scale dynamics seems to be coupled with a decrease in the average magnitude of higher frequency modes of individual residues. Furthermore, these observations indicate that enhanced dynamic motions contribute to the functional changes induced by IHP and suggest that they may be responsible for the lowered oxygen affinity triggered by these effectors.

59 BASIC BIOLOGICAL SCIENCES↗

Quality Assurance Challenges for Motion-Adaptive Radiation Therapy: Gating, Breath Holding, and Four-Dimensional Computed Tomography

Compared with conventional three-dimensional (3D) conformal radiation therapy and intensity-modulated radiation therapy treatments, quality assurance (QA) for motion-adaptive radiation therapy involves various challenges because of the added temporal dimension. Here we discuss those challenges for three specific techniques related to motion-adaptive therapy: namely respiratory gating, breath holding, and four-dimensional computed tomography. Similar to the introduction of any other new technologies in clinical practice, typical QA measures should be taken for these techniques also, including initial testing of equipment and clinical procedures, as well as frequent QA examinations during the early stage of implementation. Here, rather than covering every QA aspect in depth, we focus on some major QA challenges. The biggest QA challenge for gating and breath holding is how to ensure treatment accuracy when internal target position is predicted using external surrogates. Recommended QA measures for each component of treatment, including simulation, planning, patient positioning, and treatment delivery and verification, are discussed. For four-dimensional computed tomography, some major QA challenges have also been discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Generalized uncertainty relations and entanglement dynamics in quantum Brownian motion models

We study entanglement dynamics in quantum Brownian motion (QBM) models. Our main tool is the Wigner function propagator. Time evolution in the Wigner picture is physically intuitive and it leads to a simple derivation of a master equation for any number of system harmonic oscillators and spectral density of the environment. It also provides generalized uncertainty relations, valid for any initial state, that allow a characterization of the environment in terms of the modifications it causes to the system's dynamics. In particular, the uncertainty relations are very informative about the entanglement dynamics of Gaussian states, and to a lesser extent for other families of states. For concreteness, we apply these techniques to a bipartite QBM model, describing the processes of entanglement creation, disentanglement, and decoherence at all temperatures and time scales.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗