Search NASA⌕ Search

SEARCH · Search NASA

Results for “Resilient control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Optimized V1G and V2G Electric Vehicle Fleet Management and Grid Transaction at Marine Corps Air Station Miramar in San Diego, CA

The overall technical goal of the project was to demonstrate an all-electric bi-directional non-tactical fleet at Marine Corps Air Station (MCAS) Miramar that was integrated and controlled with other distributed energy resources (DERs) (i.e., PV, stationary battery, and building loads) to provide resilience to critical electric loads in the event of grid outages, to minimize charging costs, and to provide economic energy resources to electricity markets. In this project, the specific, technical objectives were: 1. Demonstrate that bi-directional electric vehicles can provide critical complementary services to fixed storage batteries in microgrid applications while performing function as non-tactical vehicles. 2. Demonstrate participation of bi-directional (V2G) and unidirectional (V1G) PEVs for demand management and minimization of charging costs. 3. Demonstrate integration of multiple DERs for grid service participation. US Marine Corps Air Station (MCAS) Miramar in San Diego was the site of this electric vehicle-to-microgrid-utility grid test and demonstration project. Existing microgrid assets in this study included (1) a public works building; (2) a 30-kW rooftop photovoltaic (PV) system and (3) a separate 250 kW carport PV system. In this project, six bi-directional V2G vans were located at the MCAS Miramar’s showcase building-scale microgrid to develop and test technical capabilities that V2G can provide in microgrid applications (e.g., cost reduction and resiliency). These resources provided aggregated demand management and simulated participation in current retail DR programs. The vehicles used in this demonstration were selected because they provided functionality that MCAS Miramar needed, 15 passenger transport and facilities work cargo carrying capacity, and bi-directional charging capability that the research project required. All vehicles in this study were manufactured and distributed by VIA Motors, Inc. There were six vehicles total and each was VIA’s VTRUX eREV V2G model, a modified General Motors Chevrolet 2500 2WD van. Three of the vans were configured as passenger vans and the other three were configured as cargo vans. Each van had an on-board bi-direcrtional inverter/charger, Bel Power Solutions model 350INVCHGT150-120-240-8G nominally rated at +/-15 kW. The VIA van’s charging connector follows the J1772 charging protocol. The bi-directional EVSEs demonstrated in this study were manufactured by Coritech, Inc. Each VGI-80-AC charging station enabled enhanced V2G charging capability to a Clipper Creek CS-100 charging module. The enhanced capabilities included ethernet communication following the SEP2.0 protocol with a distributed energy resource function set and an operator screen displaying real-time SOC, voltage, and current. The VGI-80-AC charging stations are classified as level 2 with a maximum current output of 80 A or effectively 19 kW. The VIA van’s onboard charger limited the charging and discharging power to 15 kW in each direction. A control computer was installed in the EWOC and connected to an existing monitor. The V2G control communication network was a completely stand-alone closed system that did not have any connection to any other networks on the base. A cybersecure remote communication connection was created with a cellular modem, firewall hardware, and a virtual private network configuration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resilience of the surface code to error bursts

Quantum error correction works effectively only if the error rate of gate operations is sufficiently low. However, some rare physical mechanisms can cause a temporary increase in the error rate that affects many qubits; examples include ionizing radiation in superconducting hardware and large deviations in the global control of atomic systems. We refer to such rare transient spikes in the gate error rate as error bursts. In this work, we investigate the resilience of the rotated surface code to generic error bursts. We assume that, after appropriate mitigation strategies, the spike in the error rate lasts for only a single syndrome-extraction cycle; we also assume that the enhanced error rate is uniform across the code block. Under these assumptions, and for a circuit-level depolarizing noise model, we perform Monte Carlo simulations to determine the regime in burst error rate and background error rate for which the memory time becomes arbitrarily long as the code block size grows. Our results indicate that suitable hardware mitigation methods combined with standard decoding methods may suffice to protect against transient error bursts in the rotated surface code.

Quantum error correction↗

Cyber-Physical Security and Resiliency Analysis Testbed for Critical Microgrids with IEEE 2030.5: Preprint

IEEE 2030.5, also known as the Common Smart Inverter Standard (CSIP) is a protocol that specifies the interface between the end user and the smart grid. This standard was proposed recently, and provides many functions which if implemented incorrectly might lead to vulnerabilities. This paper proposes a cyber-physical microgrid testbed using OpenDSS and IEEE 2030.5 that can be used to study the performance of the CSIP protocol various scenarios. For critical microgrid installations, it is essential that the critical loads are served in spite of multiple contingencies. A resiliency analysis is performed for a military microgrid to study its performance and the results are analyzed.

CVSS↗

Networked Microgrids for Improved Resilient Operation: A Case Study in Adjuntas Puerto Rico

This paper presents a case study of a network microgrid orchestrator designed to allow coordinated operation of microgrids. Through Control Hardware in the Loop (CHIL), the proposed microgrid orchestrator was validated using, as case study two community-owned microgrids in Adjuntas, Puerto Rico. These two microgrids in Adjuntas were designed to provide affordable and reliable access to electricity to 14 businesses located in the town square. In its current design, these two microgrids operate independently from each other. This paper studies how networking them would increase their resiliency metrics while operating as an island. A distributed optimization is implemented in the microgrid orchestrator due to its superior scalability compared to centralized approach as well as to maintain data privacy. Two operational modes are considered in this study to showcase the advantages of networking microgrids: a) normal island, and b) degraded island. CHIL simulations are performed to validate the proposed microgrid orchestrator. CHIL results show meaningful resiliency improvements obtained by networking microgrids during contingencies such as loss of PV generation.

Ferrari Maglia, Max↗

Interfacial Hydrogen-Bond Dynamics in Transition Metal Compounds

Understanding how water behaves when confined within atomic layers of active transition-metal carbides, nitrides, and carbonitrides is essential for uncovering the fundamental principles needed to engineer solid–liquid interfaces at the atomic scale. Yet, how lattice element chemistry and surface termination groups collectively regulate the structure and mobility of such interlayer water remains poorly understood. Here, we present a composition-controlled investigation of interlayer water dynamics in layered transition-metal nitride, carbide, and carbonitride systems using a systematic integration of quasi-elastic neutron scattering (QENS), ab initio molecular dynamics (AIMD) simulations, and density functional theory (DFT) calculations. QENS measurements show that nitride-rich systems host mobile, translationally diffusing water with thermally activated self-diffusion coefficients on the order of 10 –10 m 2 s –1 , whereas mixed C/N lattices confine water to localized, nontranslational motion that is insensitive to temperature. AIMD and DFT reveal that lattice C/N chemistry and surface functional group composition reshape the first hydration layer by modulating the surface electronic structure and termination-dependent hydrogen-bond networks, leading to pronounced differences in water ordering and thermal resilience. On the other hand, fully carbide systems exhibit intermediate behavior, highlighting that water mobility is not primarily controlled by the hydration level alone but by the coupling between lattice composition and surface chemistry. Overall, this study establishes how surface chemistry and lattice composition jointly control interfacial hydrogen bond dynamics, offering a mechanistic framework for designing transition-metal layered materials with tailored interfacial transport properties.

Hydration↗

Primal-Dual Differentiable Programming for Distribution System Critical Load Restoration: Preprint

Swift and reliable critical load restoration (CLR) can help make a distribution system resilient towards extreme events. To optimally achieve that, alongside practical concerns such as limiting online computational burden, some studies leverage model-free reinforcement learning (RL) to train control policies. Despite the advantages provided by RL algorithms, these approaches suffer from two issues: 1) the lack of a proper mechanism for constraint enforcement, and 2) poor sample efficiency. Therefore, in this paper, a primal-dual differentiable programming (PDDP) method is developed for guiding the training leading to a constraint-satisfying policy. Additionally, the model-based nature of the proposed method aims at improving sample efficiency. The experiment on a CLR problem demonstrates that PDDP can effectively train a control policy that both achieves desirable performance and satisfies required constraints.

differentiable programming↗

Co-design optimization of combined heat and power-based microgrids

With the emergent need for clean and reliable energy resources, hybrid energy systems, such as the microgrid, are widely adopted in the United States. A microgrid can consist of various distributed energy resources, for instance, combined heat and power (CHP) systems. Here, the CHP module is a distributed cogeneration technology that produces electricity and recaptures heat generated as a by-product. It is an energy-efficient technology converting heat that would otherwise be wasted to valuable thermal energy. For an optimal system configuration, this study develops a novel co-design optimization framework for CHP-based cogeneration microgrids. The framework provides the stakeholder with a method to optimize investments and attain resilient operations. The proposed co-design framework has a mixed integer programming (MIP) model that outputs decisions for both plant designs and operating controls. The microgrid considered in this study contains six components: the CHP, boiler, heat recovery unit, thermal storage system, power storage system, and photovoltaic plant. After solving the MIP model, the optimal design parameters of each component can be found to minimize the total installation cost of all components in the microgrid. Furthermore, the online costs from energy production, operation, maintenance, machine startup, and disruption-induced unsatisfied loads are minimized by solving the optimal control decisions for operations. Case studies based on designing a CHP-based microgrid with empirical data are conducted. Moreover, we consider both nominal and disruptive operational scenarios to validate the performance of the proposed co-design framework in terms of a cost-effective, resilient system.

42 ENGINEERING↗

Community Resilience Through Rapid Restoration Leveraging Distributed Energy Resources (DERs) and Low-Cost Sensors

Equitable and automated bottoms-up power restoration following an extreme event will be demonstrated at a site in Puerto Rico. To do so, the team will develop enhanced grid situational awareness techniques integrating behind-the-meter (BTM) distributed energy resources (DER) discovery, impedance sweeping based outage boundary detection, and feasible restoration path identification algorithms. Resilience metric will be developed and incorporated along with situational awareness information in a distributed Model Predictive Control (MPC)-based restoration optimization algorithm to control and mobilize grid assets. These algorithms will be validated through power hardware-in-the-loop experiments and ultimately, a site demonstration to show that outage recovery time and total recovered load could be improved by >20% over the baseline.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The evolution of the Human Systems and Simulation Laboratory in nuclear power research

The events at Three Mile Island in the United States brought about fundamental changes in the ways that simulation would be used in nuclear operations. The need for research simulators was identified to scientifically study human-centered risk and make recommendations for process control system designs. This paper documents the human factors research conducted at the Human Systems and Simulation Laboratory (HSSL) since its inception in 2010 at Idaho National Laboratory. The facility’s primary purposes are to provide support to utilities for system upgrades and to validate modernized control room concepts. In the last decade, however, as nuclear industry needs have evolved, so too have the purposes of the HSSL. Thus, beyond control room modernization, human factors researchers have evaluated the security of nuclear infrastructure from cyber adversaries and evaluated human-in-the-loop simulations for joint operations with an integrated hydrogen generation plant. Lastly, our review presents research using human reliability analysis techniques with data collected from HSSL-based studies and concludes with potential future directions for the HSSL, including severe accident management and advanced control room technologies.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Intrusion Detection for Cybersecurity of Power Electronics Dominated Grids: Inverters PQ Set-Points Manipulation

This work provides cybersecurity analytics for a high photovoltaic (PV) penetrated distribution network, representing future power electronics dominated grid (PEDG). Firstly, the impact of active and reactive power (PQ) set-points manipulation on the network is studied. Then, an intrusion detection system (IDS) is developed for identifying the potentially compromised PV inverters in the network. The proposed IDS is based on defining the normal, safe, and abnormal operation regions of the PV inverters from point of view of the steady state voltage stability of the network. These three-operation regions are identified by utilizing active power, reactive power, and voltage (PQV) limits of each specific grid-following inverter in the network. Each grid-following inverter's PQV contour includes the information of network topology, inverter ratings, and inverter controller. The developed PQ limits are integrated into the centralized secondary control layer for realization of the proposed IDS. Furthermore, the proposed secondary control layer is capable of providing remedial actions during an anomaly event to enhance the grid resiliency. The theoretical analyses are verified by several attack scenarios for a network of grid-following inverters.

41 EE - Solar Energy Technologies Office (EE-4S)↗

HOMP (Hybrid Operation and Maintenance Platform) [SWR-22-81]

The HOMP software module is contained within NREL's Hybrid Optimization and Performance Platform (HOPP) at this URL: https://github.com/NREL/HOPP/tree/feature/HOMP. HOMP is a python-based software module which can be used concurrently with the Hybrid Optimization and Performance Platform (HOPP) to model, simulate, and optimize degradation, reliability, and operations and maintenance of hybrid power plant components. The program currently models lithium ion battery, PEM electrolyzer, wind turbine, and solar PV array components, which enables users to understand the design and operation tradeoffs of hybrid power plants. For instance, HOMP enables users to answer questions like: how large does a battery bank need to be to achieve optimal charge/discharge rates for performance and reliability? How does plant design change for different objectives (e.g., profit versus resilience)? Under what conditions is it better to produce electricity versus hydrogen? How do we optimally control hybrid power plants to reduce downtime and increase performance?

Clark, Caitlyn↗

Co-simulation Framework for Community-scale Building-grid Integration [SWR-21-75]

Distributed energy resources (DERs), including rooftop solar, energy storage, and flexible loads, are gaining popularity as costs decline and as building owners and utilities realize their benefits. DERs can improve distribution system efficiency, help prevent the need for expensive grid upgrades, and increase the resilience of local communities. However, they can also cause difficulties in grid operations and can require controls to achieve their benefits. To address this challenge, NREL researchers have developed a community-scale solution that assesses the impacts of DERs and their control strategies on a distribution system. The framework has been shown to reduce solar photovoltaic (PV) curtailment to 0%, mitigate the adverse impact of solar variability on the distribution voltage, and provide up to 5-day critical load support during emergency events. Utilizing 5 different modules representing the feeder, buildings, home energy management systems, an aggregator, and a utility controller, NREL expects this simulation technology to play a critical role in the continued integration of DERs. According to the Energy Information Administration (EIA), solar curtailments accounted for 94% of the total energy curtailed in the California Independent System Operator (CAISO) in 2020. By enabling Independent System Operators (ISOs) and utility operators to bring solar curtailments to 0%, the electrical grid can become less dependent on fossil-fueled power generation sources. NREL's co-simulation framework contains five major components: Distribution Feeder Model: describes the distribution feeder topology using OpenDSS, including the locations of all DERs. Residential Building Model: simulates a large number of buildings at a high resolution using OCHRETM. The model is equipped to control equipment based on signals from an external module. The model includes major household appliances such as HVAC and a water heater, non-dispatchable load models, a distributed PV system, and a home battery system. Home Energy Management System: optimizes the controls for the devices in a home using foreseeTM. The control can adjust based on the user preferences including cost, comfort, and convenience. In hierarchical control scenarios, where the houses follow signals from an aggregator, the home energy management system provides a flexibility band with a range of power and follows the dispatch signals received from aggregator. Community-Level Aggregator: solves for optimal energy dispatch based on the flexibility bands received from each home and the grid service signal received from the utility controller. Utility-Level Controller: provides grid signals for voltage control using Distributed Energy Resources (DERs), such as solar systems, in the community.

Balamurugan, Sivasathya Pradha↗

Invasive Plant Species Management Plan for Los Alamos National Laboratory (Rev.3)

Native species are plants and animals that continually occupy a natural range without direct or indirect introduction and/or care by humans. They are adapted to the environmental conditions and processes of the ecosystem in which they reside. A species introduced into a novel ecosystem can either exploit that ecosystem and thrive or be unable to survive in that ecosystem (Hobbs et al. 2006). Alien or non-native species are species that are intentionally or accidentally introduced into a novel ecosystem and are capable of living and propagating within the physical parameters of that ecosystem. Invasive species is a species that is non-native (or alien) to the ecosystem under consideration and a noxious species are those whose introduction causes or is likely to cause economic or environmental harm. The term invasive species is applicable to plants and animals alike; however, this invasive species management plan currently focuses on invasive vegetation. Invasive plant species are usually capable of rapid colonization of disturbed ground, such as after a change in wildfire regime intensity and frequency (Reilly et al. 2020) or anthropogenic ground disturbance (Burke and Grime 1996; Hobbs and Huenneke 1992). Climate change facilitates the spread and establishment of many alien species and creates new opportunities for them to become invasive (Turbelin and Catford 2021). As climate change impacts increase in the coming decades, we may see in an increase in invasive species establishment. See a list of definitions of terms pertinent to this document in Appendix A: Definitions. Los Alamos National Laboratory (LANL) hosts populations of non-native and invasive species all typical of the northern New Mexico region (Martin 2004; NMDA 2020). By implementing an invasive species management plan, LANL will have readily accessible management strategies for invasive species that are found on-site. The benefits of managing invasive species include a decrease in wildland fire risks, an increase in soil productivity, an increase in (productive or beneficial) wildlife habitat, an increase in water quantity and quality, and the restoration of impacted areas (Burke and Grime 1996; Hobbs and Huenneke 1992; D’Antonio and Hobbie 2005; MacDougall et al. 2013; Reilly et al. 2020). The aforementioned benefits from invasive species management directly enable the LANL mission by ensuring compliance requirements are met and site-wide programs, such as the Vulnerability Assessment and Resilience Plan, are supported for a mutually beneficial outcome. An example for the LANL site specifically, controlling non-native annual plant species, for example, could reduce the costs associated with stabilizing soils during the stormwater pollution prevention compliance process. Roadway and utility right-of-way areas are another place where an integrated vegetation management strategy would promote low growing perennial plants in a way that is mutually beneficial to habitat and the institution through lowered maintenance costs. There is also an economic benefit to managing invasive species. In one nationwide study, invasive plants had an estimated impact cost of $190.45 billion (Fantel-Lepczyk et al. 2022). Investing in preventative measures and surveillance could help to offset future control and management costs of invasive species that have the potential to become established. The State of New Mexico has developed plant species lists and recommendations through the New Mexico Department of Agriculture’s Noxious Weeds Management Act, Article 7D (NM Statute § 76-7D-4 2021); however, effective invasive species management must rely on local knowledge of the site and region. Los Alamos County (LAC) has already compiled a target invasive plant species list and species-specific management objectives (Martin 2004). Therefore, the New Mexico Noxious Weed List and the LAC invasive plant species list, as well as management objectives from those documents, are integrated into LANL’s invasive plant species management plan.

54 ENVIRONMENTAL SCIENCES↗

Reducing Risk With ASHRAE Standard 241

ASHRAE Standard 241’s requirements can make indoor spaces more resilient to the spread of airborne infectious diseases. Buildings that comply with ASHRAE Standard 241-2023, Control of Infectious Aerosols,1 will have the capacity to respond during times of elevated risk with systems that provide the necessary equivalent clean airflow for infection control (VECAi). To reduce risk effectively, these systems need to operate properly. This column explores Standard 241’s requirements for operations and maintenance in high-risk times (infection risk management mode or IRMM) and the importance of creating a Building Readiness Plan.

ashrae standard 241, Operations and Maintenance, b↗

Modeling of a Networked Community Microgrid with High Solar Penetration Considering Control Dynamics of Inverter-Based Resources

Microgrids help facilitate the integration of renewable energy in distribution-level grids and increase the resilience of the electric grid to extreme weather, especially in rural areas. Compared to traditional microgrids, a networked microgrid leverages multiple grid-forming sources to form a potential meshed grid and is more flexible in operation. This paper demonstrates the simulation modeling of an actual networked microgrid located in Adjuntas, Puerto Rico. The model contains representations of power inverters that connect the battery energy storage systems and photovoltaic generation systems to the networked microgrid and is capable of simulating fast grid transients as well as long-term operation of the networked microgrid. The modeling technique for power inverters allows the time-efficient simulation of the microgrid with a minimal penalty on model accuracy.

Li, Dingrui↗

Advanced Transmission Technologies – GETs and HPCs Session 2: Advanced Power Flow Control and Transmission Topology Optimization

The INL TADA GETs Cohort Session 2, held on November 7, 2025, conducted in collaboration with ScottMadden, focused on two core Advanced Transmission Technologies (ATTs): Advanced Power Flow Control (APFC) and Transmission Topology Optimization (TTO). These technologies are pivotal in enhancing grid flexibility, reliability, and cybersecurity resilience. APFC, particularly through modular FACTS devices like Modular Static Synchronous Series Compensators (M-SSSCs), enables dynamic voltage injection to reroute power flows. The session highlighted the deployment benefits of APFC, such as rapid installation, minimal civil works, and re-deployability. Regulatory drivers like FERC Order 2023 mandate the inclusion of Grid-Enhancing Technologies (GETs) in interconnection studies. Case studies from Central Hudson, CAISO, and National Grid (UK) demonstrated APFC’s effectiveness in congestion relief and cost savings. The session also addressed cybersecurity concerns, including firmware vulnerabilities, SCADA integration risks, and supply chain dependencies. Participants engaged in interactive exercises to rank cybersecurity and supply chain risks, emphasizing the need for robust digital assurance strategies. TTO involves software-based reconfiguration of transmission networks to optimize power flow without new infrastructure. The session showcased its operational value, with examples from SPP, PJM, and MISO showing significant congestion cost reductions. Cybersecurity vulnerabilities were discussed, particularly in API security and software supply chains, referencing incidents like SolarWinds and attacks on Danish utilities. Digital assurance exercises explored worst-case scenarios, attack paths, and mitigation responsibilities between vendors and utilities. Reliability challenges such as algorithm stability, vendor dependency, and operator trust were also examined. Cross-cutting themes emphasized the importance of digital assurance tools, including Software Bills of Materials (SBOMs) and hardware-in-loop testing. Human performance, training, and operational confidence were identified as critical enablers of technology adoption. The session concluded with a preview of Session 3, which will focus on High Performance Conductors (HPCs) and risk-based cybersecurity tools. Session 2 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

An Operational Resilience Metric to Evaluate Inertia and Inverter-based Generation on the Grid

In an effort to reduce carbon emissions and curtail the effects of climate change there has been considerable effort to increase the penetration of inverter-based renewable energy sources. The adoption of renewable generation over conventional inertia-based generation sources is forming considerable challenges for the operation and stability of the power system. The power system has been designed around generation units characterized by high inertia and primary frequency response (PFR), allowing them to respond to disturbances such as faults or generators tripping off line. In contrast, the modern inverter-based assets are characterized by no contribution to inertia and they typically provide stochastic generation at their maximum output, thus having no contribution to PFR during low-frequency disturbance events. Because of this, inertia in power systems is reducing, resulting in a faster rate of frequency change after a disturbance occurs. As more inverter-based generation units are added to the grid it is important to understand the stability of the system and the size of disturbance a system is capable of withstanding. This paper presents a resilience metric that evaluates the maximum size of disturbance a systems can withstand based on the system inertia and the primary frequency control of inverter and inertia-based generation. The results are shown visually and are based on the real-time operation of generation units and their characteristics such as latency, ramp rates, and energy constraints. It is demonstrated that the real-time positioning or bias of the generating units has an effect of the size of disturbance that a system can withstand, i.e. its resilience. It is expected that this type of analysis can help operators increase the resilience of power systems in the future.

13 HYDRO ENERGY↗