Search NASA⌕ Search

SEARCH · Search NASA

Results for “Response Spectra”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Hail Monitor Sensor

An inexpensive and simple hail monitor design has been developed that has a single piezoelectric ceramic disc and uses a metal plate as a sounding board. The structure is durable and able to withstand the launch environment. This design has several advantages over a multi-ceramic sensor, including reduced cost and complexity, increased durability, and improvement in impact response uniformity over the active surface. However, the most important characteristic of this design is the potential to use frequency discrimination between the spectrum created from raindrop impact and a hailstone impact. The sound of hail hitting a metal plate is distinctly different from the sound of rain hitting the same plate. This fortuitous behavior of the pyramid sensor may lead to a signal processing strategy, which is inherently more reliable than one depending on amplitude processing only. The initial concept has been im proved by forming a shallow pyramid structure so that hail is encouraged to bounce away from the sensor so as not to be counted more than once. The sloped surface also discourages water from collecting. Additionally, the final prototype version includes a mounting box for the piezo-ceramic, which is offset from the pyramid apex, thus helping to reduce non-uniform response (see Figure 2). The frequency spectra from a single raindrop impact and a single ice ball impact have been compared. The most notable feature of the frequency resonant peaks is the ratio of the 5.2 kHz to 3.1 kHz components. In the case of a raindrop, this ratio is very small. But in the case of an ice ball, the ratio is roughly one third. This frequency signature of ice balls should provide a robust method for discriminating raindrops from hailstones. Considering that hail size distributions (HSDs) and fall rates are roughly 1 percent that of rainfall, hailstone sizes range from a few tenths of a centimeter to several centimeters. There may be considerable size overlap between large rain and small hail. As hail occurs infrequently at KSC, the ideal HSD measurement sensor needs to have a collection area roughly 100 times greater than a raindrop-size distribution sensor or disdrometer. The sensitivity should be such that it can detect and count very small hail in the midst of intense rainfall consisting of large raindrop sizes. The dynamic range and durability should allow measurement of the largest hail sizes, and the operation and calibration strategy should consider the infrequent occurrence of hail fall over the KSC area.

Younquist, Robert↗

Improved Charge-Transfer Fluorescent Dyes

Improved charge-transfer fluorescent dyes have been developed for use as molecular probes. These dyes are based on benzofuran nuclei with attached phenyl groups substituted with, variously, electron donors, electron acceptors, or combinations of donors and acceptors. Optionally, these dyes could be incorporated as parts of polymer backbones or as pendant groups or attached to certain surfaces via self-assembly-based methods. These dyes exhibit high fluorescence quantum yields -- ranging from 0.2 to 0.98, depending upon solvents and chemical structures. The wavelengths, quantum yields, intensities, and lifetimes of the fluorescence emitted by these dyes vary with (and, hence, can be used as indicators of) the polarities of solvents in which they are dissolved: In solvents of increasing polarity, fluorescence spectra shift to longer wavelengths, fluorescence quantum yields decrease, and fluorescence lifetimes increase. The wavelengths, quantum yields, intensities, and lifetimes are also expected to be sensitive to viscosities and/or glass-transition temperatures. Some chemical species -- especially amines, amino acids, and metal ions -- quench the fluorescence of these dyes, with consequent reductions in intensities, quantum yields, and lifetimes. As a result, the dyes can be used to detect these species. Another useful characteristic of these dyes is a capability for both two-photon and one-photon absorption. Typically, these dyes absorb single photons in the ultraviolet region of the spectrum (wavelengths < 400 nm) and emit photons in the long-wavelength ultraviolet, visible, and, when dissolved in some solvents, near-infrared regions. In addition, these dyes can be excited by two-photon absorption at near-infrared wavelengths (600 to 800 nm) to produce fluorescence spectra identical to those obtained in response to excitation by single photons at half the corresponding wavelengths (300 to 400 nm). While many prior fluorescent dyes exhibit high quantum yields, solvent-polarity- dependent fluorescence behavior, susceptibility to quenching by certain chemical species, and/or two-photon fluorescence, none of them has the combination of all of these attributes. Because the present dyes do have all of these attributes, they have potential utility as molecular probes in a variety of applications. Examples include (1) monitoring curing and deterioration of polymers; (2) monitoring protein expression; (3) high-throughput screening of drugs; (4) monitoring such chemical species as glucose, amines, amino acids, and metal ions; and (5) photodynamic therapy of cancers and other diseases.

Meador, Michael↗

In-Flight Turbulence Emulation for Fixed-Wing Aircraft using Equivalent Multisine Excitations

A procedure is discussed for designing control-equivalent turbulence input (CETI) excitations to emulate a fixed-wing aircraft response to turbulence while flying through calm air. These excitations are added to the actuator commands to produce the same motion of the aircraft that would have resulted from flying in actual turbulence. Although CETI models are usually shaping filters driven by white noise inputs, the equivalent control inputs in this report were constructed as multisine excitations, which enables mimicking the response to turbulence with arbitrary power spectra, within hardware limitations. Practical aspects of the approach are discussed, such as actuator dynamics, model uncertainty, actual in-flight turbulence, and others. The procedure is demonstrated using a flight dynamics simulation model of a subscale generic jet transport aircraft.

control-equivalent turbulence inputs (CETI)↗

Mineral composition of Al-rich float rocks in Jezero crater as seen by Super-Cam

During its traverse across the Jezero crater floor and western fan, the Perseverance rover encountered > 4000 float rocks – of variable size (up to ~ 50 cm) scattered on the ground without apparent connection to the surrounding stratigraphy [1]. Analysis performed using the SuperCam instrument’s [2,3,4], Laser Induced Breakdown Spectroscopy (LIBS) revealed a high concentration of Al 2 O 3 , Cr, Ti and Ni [5], and very low of Fe, Mg, Ca and Na [5, 1]. SuperCam’s infrared reflectance spectroscopy (IRS, between 1.3 and 2.6 μm) showed the presence of Al-rich aqueous alteration minerals (characteristic absorption bands of kaolinite and Al-smectites at 1.4 and 2.2 μm) as well as some (likely Cr-) spinels, identified uthrough their broad asymmetric 2 μm band, responsible for the concavity of IR spectra. These mineral species alone do not fully account for the spectral shapes; hence, the objective is to further investigate spectral modeling to determine the most probable mineral assemblages. Here, we present the results of modeling 17 light-toned float rocks, up to Sol 924, complementary to [1].

C. Royer↗

Diamond as a solid state micro-fission chamber for thermal neutron detection at the VR-1 research reactor

Diamond exhibits a combination of properties which makes it attractive for neutron detection in hostile conditions. In the particular case of detection in a nuclear reactor, it is resilient to radiation, exhibits a natural low sensitivity to gamma rays, and its small size (as compared with that of gas ionisation chambers) enables fluency monitoring with a high position resolution. We report here on the use of synthetic CVD diamond as a solid state micro-fission chamber with U-235 converting material for in-core thermal neutron monitoring. Two types of thin diamond detectors were developed for this application. The first type of detector is fabricated using thin diamond membrane obtained by etching low-cost commercially available single crystal CVD intrinsic diamond, so called 'optical grade' material. Starting from a few hundred of micrometre thick samples, the sample is sliced with a laser and then plasma etched down to a few tenths of micrometre. Here we report the result obtained with a 17 μm thick device. The detection surface of this detector is equal to 1 mm{sup 2}. Detectors with surfaces up to 1 cm{sup 2} can be fabricated with this technique. The second type of detector is fabricated by growing successively two thin films of diamond, by the microwave enhanced chemical vapour deposition technique, on HPHT single crystal diamond. A first, a film of boron doped (p+) single crystal diamond, a few microns thick, is deposited. Then a second film of intrinsic diamond with a thickness of a few tens of microns is deposited. This results in a P doped, Intrinsic, Metal structure (PIM) structure in which the intrinsic volume id the active part of the detector. Here we report the results obtained with a 20 μm thick intrinsic whose detection surface is equal to 0.5 mm{sup 2}, with the possibility to enlarge the surface of the detector up to 1 cm{sup 2}. These two types of detector were tested at the VR-1 research reactor at the Czech Technical University in Prague. The Training Reactor VR-1 is a pool type (light water) reactor based on UO{sub 2} low enriched uranium. It has a nominal power of 1 kW, and can be operated for a short period up to 5 kW. The arrangement of the reactor pool reactor facilitates access to the core, setting and removal of various experimental samples and detectors, and safe and easy handling of fuel assemblies. The reactor is equipped with two horizontal channels (radial and tangential) and 10 vertical channels, of varying diameters, which can be loaded into various core positions, and one pneumatic transfer system. It is also equipped with several specifically designed educational instrumentation systems that can be used to supply complementary measurements and characterization around the reactor. The reactor is operated by the Department of Nuclear Reactors of the Faculty of Nuclear Sciences and Physical Engineering of the Czech Technical University in Prague. The two detectors were placed in-core through one of the vertical insertion channel. They were coupled to remote placed (5 m BNC cable) classical nuclear charge sensitive electronics. Detection properties of both sensors, including: pulse height spectra of U-235 fission fragments (response linearity with neutron flux, count rate, gamma background, were evaluated varying the power of the reactor from 0.005 W to 500 W. The evolution of the counting rate of the thinned optical grade detector as a function of counting rate of a gas ionization chamber used currently for reactor monitoring shows the very good linearity of the detector over the 5 decades. Similar results were obtained with the PIM detector. Additionally fast transient current signals of the detectors were recorded on a digital storage oscilloscope (DSO) using broad-band amplifier and with a simple bias-T, showing potential use of such sensors for neutron counting with no need of an amplification stage, since non-amplified signals from fission fragments exceeded 4 mV in amplitude. Therefore, one can think of simple neutron counting system by feeding diamond detectors signals directly to the low threshold discriminators. The results obtained on the VR1 will be described and discussed in detail in the paper and associated presentation. The results demonstrate that diamond micro-fission chambers can be used for in-core neutron monitoring, where robust, simple and compact devices are required.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Measurements of NaI:Tl Electron Response using SLYNCI: Comparison of Different Samples

This paper measures the sample to sample variation in the light yield non-proportionality of NaI:Tl, and so explores whether this is an invariant characteristic of the material or whether it is dependent on the chemical and physical properties of tested sample. In this work we report on the electron response of nine crystals of NaI(Tl), differing in shape, volume, age, manufacturer and quality. The non-proportionality has been measured at the SLYNCI facility in the energy range between 3.5 to 460 keV. The Scintillation Light Yield Non-proportionality Characterization Instrument (SLYNCI) is a next generation Compton Coincidence device, explicitly designed to study the 'non-proportionality' of the electron response in scintillators and the contribution of this effect to the intrinsic energy resolution. We also discuss the gamma response, x-ray excited emission spectra and decay times for the nine crystals, in order to provide a complete characterization of their physical properties and determine whether the mechanism of scintillation varies between samples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Discovery of deep and shallow trap states from step structures of rutile TiO{sub 2} vicinal surfaces by second harmonic and sum frequency generation spectroscopy

In this report, local electronic structures of steps and terraces on rutile TiO{sub 2} single crystal faces were studied by second harmonic and sum frequency generation (SHG/SFG) spectroscopy. We attained selective measurement of the local electronic states of the step bunches formed on the vicinal (17 18 1) and (15 13 0) surfaces using a recently developed step-selective probing technique. The electronic structures of the flat (110)-(1x1) (the terrace face of the vicinal surfaces) and (011)-(2x1) surfaces were also discussed. The SHG/SFG spectra showed that step structures are mainly responsible for the formation of trap states, since significant resonances from the trap states were observed only from the vicinal surfaces. We detected deep hole trap (DHT) states and shallow electron trap (SET) states selectively from the step bunches on the vicinal surfaces. Detailed analysis of the SHG/SFG spectra showed that the DHT and SET states are more likely to be induced at the top edges of the step bunches than on their hillsides. Unlike the SET states, the DHT states were observed only at the step bunches parallel to [1 1 1][equivalent to the step bunches formed on the (17 18 1) surface]. Photocatalytic activity for each TiO{sub 2} sample was also measured through methylene blue photodegradation reactions and was found to follow the sequence: (110) < (17 18 1) < (15 13 0) < (011), indicating that steps along [0 0 1] are more reactive than steps along [1 1 1]. This result implies that the presence of the DHT states observed from the step bunches parallel to [1 1 1] did not effectively contribute to the methylene blue photodegradation reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using LiF:Mg,Cu,P TLDs to estimate the absorbed dose to water in liquid water around an {sup 192}Ir brachytherapy source

Purpose: The absorbed dose to water is the fundamental reference quantity for brachytherapy treatment planning systems and thermoluminescence dosimeters (TLDs) have been recognized as the most validated detectors for measurement of such a dosimetric descriptor. The detector response in a wide energy spectrum as that of an{sup 192}Ir brachytherapy source as well as the specific measurement medium which surrounds the TLD need to be accounted for when estimating the absorbed dose. This paper develops a methodology based on highly sensitive LiF:Mg,Cu,P TLDs to directly estimate the absorbed dose to water in liquid water around a high dose rate {sup 192}Ir brachytherapy source. Methods: Different experimental designs in liquid water and air were constructed to study the response of LiF:Mg,Cu,P TLDs when irradiated in several standard photon beams of the LNE-LNHB (French national metrology laboratory for ionizing radiation). Measurement strategies and Monte Carlo techniques were developed to calibrate the LiF:Mg,Cu,P detectors in the energy interval characteristic of that found when TLDs are immersed in water around an{sup 192}Ir source. Finally, an experimental system was designed to irradiate TLDs at different angles between 1 and 11 cm away from an {sup 192}Ir source in liquid water. Monte Carlo simulations were performed to correct measured results to provide estimates of the absorbed dose to water in water around the {sup 192}Ir source. Results: The dose response dependence of LiF:Mg,Cu,P TLDs with the linear energy transfer of secondary electrons followed the same variations as those of published results. The calibration strategy which used TLDs in air exposed to a standard N-250 ISO x-ray beam and TLDs in water irradiated with a standard{sup 137}Cs beam provided an estimated mean uncertainty of 2.8% (k = 1) in the TLD calibration coefficient for irradiations by the {sup 192}Ir source in water. The 3D TLD measurements performed in liquid water were obtained with a maximum uncertainty of 11% (k = 1) found at 1 cm from the source. Radial dose values in water were compared against published results of the American Association of Physicists in Medicine and the European Society for Radiotherapy and Oncology and no significant differences (maximum value of 3.1%) were found within uncertainties except for one position at 9 cm (5.8%). At this location the background contribution relative to the TLD signal is relatively small and an unexpected experimental fluctuation in the background estimate may have caused such a large discrepancy. Conclusions: This paper shows that reliable measurements with TLDs in complex energy spectra require a study of the detector dose response with the radiation quality and specific calibration methodologies which model accurately the experimental conditions where the detectors will be used. The authors have developed and studied a method with highly sensitive TLDs and contributed to its validation by comparison with results from the literature. This methodology can be used to provide direct estimates of the absorbed dose rate in water for irradiations with HDR{sup 192}Ir brachytherapy sources.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Understanding the impact of nuclear-data covariances on various integral responses using adjustment

The EUCLID (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) project created a library of sensitivities for nine different integral responses with respect to nuclear data. These integral responses were obtained from measurements at LLNL (Lawrence Livermore National Laboratory) pulsed spheres, critical and sub-critical assemblies. At the same time, covariances for ENDF/B-VIII.0 were processed at LANL (Los Alamos National Laboratory). The combination of these data allow us to study the impact of nuclear-data covariances on various integral responses, either by forward-propagating covariances via sensitivities, or by using nuclear data, integral responses, and sensitivities for adjustment. Here, we will present: the impact of 1 H, 9 Be, 12 C, 27 Al, 56 Fe, 235,238 U, and 239,240 Pu ENDF/B-VIII.0 covariances on simulated bounds of the following integral responses: LLNL pulsed-spheres neutron-leakage spectra, the effective neutron multiplication factor, reaction rates, and reactivity coefficients of ICSBEP critical assemblies. Also, adjustment results with the same nuclear-data covariances and responses will be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulated response of a multispectral scanner over wheat as a function of wavelength and view/illumination directions

Oblique viewing sensors are to be launched in the late 1980's on the Multispectral Resource Sampler, being developed by the U.S. Since the resulting oblique measurements will need to be better understood, the reflectance response with a view angle of wheat, excluding atmospheric effects but simulating the response of a multispectral scanner, is analyzed. Spectra were taken continuously in the wavelength range of 0.45 to 2.4 microns at more than 1200 view/illumination directions with a 20 C spectral radiometer, and data were acquired six meters above four wheat canopies, each at a different stage of growth. The study shows that the canopy reflective response is a function of the illumination angle, the scanner view angle, and the wavelength; and the variation is greater at low solar variations.

Vanderbilt, V. C.↗

Angular dependences of the luminescence and density of photon states in a chiral liquid crystal

Luminescence spectra of a laser dye-doped chiral liquid crystal have been studied in a wide range of angles (up to 60°) to the axis of its helical structure using a semicylindrical quartz prism, which made it possible to observe the shift and evolution of the photonic band gap in response to changes in angle. Using measured spectra and numerical simulation, we calculated the spectral distributions of the density of photon states in such a cholesteric crystal for polarised and unpolarised light, which characterise its structure as that of a chiral one-dimensional photonic crystal. (optics of liquid crystals)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of NaI(Tl) electron response: comparison of different samples

This paper measures the sample to sample variation in the light yield proportionality of NaI(Tl), and so explores whether this is an invariant characteristic of the material or whether it depends on the chemical and physical properties of the tested samples. We report on the electron response of nine crystals of NaI(Tl), differing in shape, volume, age, manufacturer and quality. The proportionality has been measured at the SLYNCI facility in the energy range between 3.5 to 460 keV. We observe that while samples produced by the same manufacturer at approximately the same time have virtually identical electron response curves, there are significant sample to sample variations among crystals produced by different manufacturers or at different times. In an effort to correlate changes in the electron response with details of the scintillation mechanism, we characterized other scintillation properties, including the gamma response and the x-ray excited emission spectra and decay times, for the nine crystals. While sample to sample differences in these crystals were observed, we have been unable to identify the underlying fundamental mechanisms that are responsible for these differences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electric Field Analysis in a Cold-Ion Source Using Stark Spectroscopy of Rydberg Atoms

Here, we analyze electric fields in ion sources generated by quasicontinuous photoionization of cold Rb atoms trapped in the focal spot of a near-concentric, in-vacuum cavity for 1064-nm laser light. Ion streams are extracted with an external electric field, F. Stark effects of Rb 57F and of nearby high-angular-momentum Rydberg levels, which exhibit large, linear Stark shifts, are employed to study the net electric-field probability distribution within the ion-source region over an extraction-field range of 0 < F < 0.35 V/cm. For F = 0, we also investigate ion-field-induced Stark spectra of the 60P 1/2 state, which exhibits a (lesser) quadratic electric-field response that affords a simplified electric-field analysis. Experimental Rydberg spectra are compared with theoretical Stark spectra, which are weighted with net electric-field distributions obtained from classical ion-trajectory simulations that include Coulomb interactions. Experiments and models are in good agreement. At small F and high ion-source rates, the field approximately follows a Holtsmark distribution, and the ion streams are degraded by the Coulomb microfields. With increasing F and at lower ion-source rates, the fields become narrowly distributed around F, resulting in directional ion streams that are less degraded by microfields. Our results are of interest for monitoring cold-ion sources for focused-ion-beam applications, where Coulomb interactions are of concern, and for studies of electric fields in cold plasmas.

74 ATOMIC AND MOLECULAR PHYSICS↗

Optical and plasmonic spectroscopy with cantilever shaped materials

Micro- and nanocantilevers, which have traditionally played a vital role in the development of force microscopy, and more recently a special role in biological, chemical and physical sensing and detection, have received comparatively little attention in optical spectroscopy. We present an investigation of the optical response of microcantilevers towards their utilization in integrated spectrometers in a broad part of the spectrum. By discussing the overall actuation mechanism we describe how surface modes may effectively contribute to the final signal. Using Fourier transform infrared (FTIR) spectroscopy, a series of multilayered microcantilevers are characterized for their spectral response in the range from 7800 to 400 cm{sup -1}. Transmission FTIR and FTIR photothermal spectroscopy are carried out using polystyrene with well-established infrared spectra.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laboratory measurements of radiance and reflectance spectra of dilute secondary-treated sewage sludge

The National Aeronautics and Space Administration (NASA), in cooperation with the Environmental Protection Agency (EPA) and the National Oceanic and Atmospheric Administration (NOAA), conducted a research program to evaluate the feasibility of remotely monitoring ocean dumping of waste products such as acid and sewage sludge. One aspect of the research program involved the measurements of upwelled spectral signatures for sewage-sludge mixtures of different concentrations in an 11600-liter tank. This paper describes the laboratory arrangement and presents radiance and reflectance spectra in the visible and near-infrared ranges for concentrations ranging from 9.7 to 180 ppm of secondary-treated sewage sludge mixed with two types of base water. Results indicate that upwelled radiance varies in a near-linear manner with concentration and that the sludge has a practically flat signal response between 420 and 970 nm. Reflectance spectra were obtained for the sewage-sludge mixtures at all wavelengths and concentrations.

Witte, W. G.↗

Ocular input for human melatonin regulation: relevance to breast cancer

The impact of breast cancer on women across the world has been extensive and severe. As prevalence of breast cancer is greatest in industrialized regions, exposure to light at night has been proposed as a potential risk factor. This theory is supported by the epidemiological observations of decreased breast cancer in blind women and increased breast cancer in women who do shift-work. In addition, human, animal and in vitro studies which have investigated the melatonin-cancer dynamic indicate an apparent relationship between light, melatonin and cancer, albeit complex. Recent developments in understanding melatonin regulation by light in humans are examined, with particular attention to factors that contribute to the sensitivity of the light-induced melatonin suppression response. Specifically, the role of spectral characteristics of light is addressed, and recent relevant action spectrum studies in humans and other mammalian species are discussed. Across five action spectra for circadian and other non-visual responses, a peak sensitivity between 446-484 nm was identified. Under highly controlled exposure circumstances, less than 1 lux of monochromatic light elicited a significant suppression of nocturnal melatonin. In view of the possible link between light exposure, melatonin suppression and cancer risk, it is important to continue to identify the basic related ocular physiology. Visual performance, rather than circadian function, has been the primary focus of architectural lighting systems. It is now necessary to reevaluate lighting strategies, with consideration of circadian influences, in an effort to maximize physiological homeostasis and health.

Review↗

Silicon Damage Response Function Derivation and Verification: Assessment of Impact on ASTM Standard E722

Unsuccessful attempts by members of the radiation effects community to independently derive the Norgett-Robinson-Torrens (NRT) damage energy factors for silicon in ASTM standard E722-14 led to an investigation of the software coding and data that produced those damage energy factors. The ad hoc collaboration to discover the reason for lack of agreement revealed a coding error and resulted in a report documenting the methodology to produce the response function for the standard. The recommended changes in the NRT damage energy factors for silicon are shown to have significant impact for a narrow energy region of the 1-MeV(Si) equivalent fluence response function. However, when evaluating integral metrics over all neutrons energies in various spectra important to the SNL electronics testing community, the change in the response results in a small decrease in the total 1- MeV(Si) equivalent fluence of ~0.6% compared to the E722-14 response. Response functions based on the newly recommended NRT damage energy factors have been produced and are available for users of both the NuGET and MCNP codes.

36 MATERIALS SCIENCE↗