Search NASA⌕ Search

SEARCH · Search NASA

Results for “SOLAR GENERATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Operating Strategies for Dispatchable PEM Electrolyzers that Enable Low-Cost Hydrogen Production

Hydrogen is a pathway to enabling decarbonization across multiple economic sectors that cannot be directly decarbonized with electricity including heat for industrial operations, medium- and heavy-duty transportation applications, long-duration energy storage, and as a feedstock for chemical synthesis. Producing hydrogen at low costs and carbon footprint is likely essential to economically decarbonize these otherwise "hard to decarbonize" sectors. Low-temperature polymer electrolyte membrane (PEM) electrolysis produces hydrogen from water and electricity and is a rapidly developing pathway towards making hydrogen at the scales required for decarbonization applications. The levelized cost of electrolytic hydrogen is dependent on the capital cost, efficiency, and durability of the electrolyzer system as well as the price of electricity supplied to the electrolyzer and the annual utilization of the electrolyzer (capacity factor). Electricity price and capacity factor depend on the source of energy that the system uses and impact other economic factors. Electricity price and capacity factor and the connections between other aspects of hydrogen production via PEM electrolyzers are the focus of this work. PEM electrolyzers have conventionally been operated at high capacity factors using electricity purchased from utilities with a constant price throughout the year. To achieve lower effective electricity prices, recent work has investigated opportunities for electrolyzers to purchase electricity in wholesale markets, where the cost of electricity varies hourly. This option can lead to lower electricity costs when the electrolyzer is a controllable load that ramps up and down rapidly and turns on and off frequently. This configuration and operating strategy capitalizes on times of low wholesale electricity prices and results in lower hydrogen levelized costs than constant operation due to reduced electricity costs even though the reduced capacity factor increases the cost of recovering the capital investment. Cycling on and off frequently also has implications for electrolyzer durability. An electrolyzer configuration where it is directly connected to renewable generation such as wind or solar, only running when the generator is producing energy, has similar implications on operating strategy, hydrogen levelized cost, capacity factor, and durability. This work provides insight into the relationships between dispatchable electrolyzer operating strategies and the cost of producing hydrogen from these systems, outlining strategies and opportunities to minimize production costs while minimizing operations that are likely to negatively impact system durability and efficiency. We find strategies that minimize electrolyzer cycling and the resulting durability impacts while increasing the hydrogen levelized cost only slightly above the minimum. We also find opportunities for batteries to minimize the number of cycles in systems directly connected to renewable generation. These findings outline key opportunities for future electrolyzer deployments and the synergistic benefits between electrolyzers and increased deployment of renewable energy generation like wind and solar. They also inform research and development that is reducing electrolyzer capital cost while managing durability impacts.

electricity markets↗

Error-Level-Controlled Synthetic Forecasts for Renewable Generation

Renewable energy resources, including solar and wind energy, play a significant role in sustainable energy systems. However, the inherent uncertainty and intermittency of renewable generation pose challenges to the safe and efficient operation of power systems. Recognizing the importance of short-term (hours ahead) renewable generation forecasting in power systems operation, it becomes crucial to address the potential inaccuracies in these forecasts. To systematically evaluate the performance of controllers in the presence of imperfect forecasts, we generate synthetic forecasts using actual renewable generation profiles (one from solar and one from wind). These synthetic forecasts incorporate different levels of statistical error, allowing us to control and manipulate the accuracy of the predictions. The primary objective is to employ synthetic forecasts with controlled yet realistic error levels to systematically investigate how controllers adapt to variations in forecast accuracy, providing valuable insights into their robustness and effectiveness under real-world conditions.

Array↗

Vapor-Processing of Metal Halide Perovskite Thin Films and Solar Cells

Metal-halide perovskites are an emerging material for next generation high efficiency solar cells. In this presentation, we review our work in processing metal-halide perovskites via a dry, carrier-gas assisted vapor deposition method, and its ability to be useful for the formation of all-perovskite heterojunctions. We also outline recent work demonstrating the viability of this method for the deposition of lead-based perovskites via co-deposition.

14 SOLAR ENERGY↗

Storage Futures Study: Grid Operational Impacts of Widespread Storage Deployment

This report, the fifth in the Storage Futures Study series, uses cost-driven scenarios from the ReEDS model as a starting point to examine the operational impacts of grid-scale storage deployment and relationships between this deployment and the contribution of variable renewable energy. We use commercial production cost modeling software to evaluate hourly operation of five scenarios that reach between 210 gigawatts (GW) and 930 GW of installed storage by 2050. We find that storage plays an important role in these power systems between now and 2050 - by storing the lowest-marginal cost generation (often, overgeneration from solar or wind plants) and generating energy during the highest net load periods of the day and year. Storage helps with the integration of variable renewable energy and by providing an important resource to provide continued reliable power.

25 ENERGY STORAGE↗

Storage Futures Study: Grid Operational Impacts of Widespread Storage Deployment

This report, the fifth in the Storage Futures Study series, uses cost-driven scenarios from the ReEDS model as a starting point to examine the operational impacts of grid-scale storage deployment and relationships between this deployment and the contribution of variable renewable energy. We use commercial production cost modeling software to evaluate hourly operation of five scenarios that reach between 210 gigawatts (GW) and 930 GW of installed storage by 2050. We find that storage plays an important role in these power systems between now and 2050 - by storing the lowest-marginal cost generation (often, overgeneration from solar or wind plants) and generating energy during the highest net load periods of the day and year. Storage helps with the integration of variable renewable energy and by providing an important resource to provide continued reliable power.

battery↗

Benchmarking of Solar Irradiance Nowcast Performance Derived from All-Sky Imagers

Fluctuations of the incoming solar irradiance impact the power generation from photovoltaic and concentrating solar thermal power plants. Accurate solar nowcasting becomes necessary to detect these sudden changes of generated power and to provide the desired information for optimal exploitation of solar systems. In the framework of the International Energy Agency's Photovoltaic Power Systems Program Task 16, a benchmarking exercise has been conducted relying on a bouquet of solar nowcasting methodologies by all-sky imagers (ASI). In this paper, four ASI systems nowcast the Global Horizontal Irradiance (GHI) with a time forecast ranging from 1 to 20 min during 28 days with variable cloud conditions spanning from September to November 2019 in southern Spain. All ASIs demonstrated their ability to accurately nowcast GHI, with RMSE ranging from 6.9% to 18.1%. Under cloudy conditions, all ASIs' nowcasts outperform the persistence models. Under clear skies, three ASIs are better than persistence. Discrepancies in the observed nowcasting performance become larger at increasing forecast horizons. The findings of this study highlight the feasibility of ASIs to reliably nowcast GHI at different sky conditions, time intervals and horizons. Such nowcasts can be used either to estimate solar power at distant times or detect sudden GHI fluctuations.

all-sky imagers↗

Irradiation Experiments on High Efficiency Nanowire Solar Cells Including Tilted Incidence Angle

Nanowire based solar cells have promising potential to become the next generation of space solar cells. In this study we corroborate their high radiation tolerance by irradiating high efficiency GaAs (efficiency > 15 %) nanowire solar cells with 1 MeV electrons at a fluence of 10 16 e - /cm 2 . Additionally, we theoretically show that the damage in nanowire solar cells is expected to be slightly dependent on the incidence angle and the geometry of the nanowire array. However, experimentally, two sets of GaAs nanowire solar cells have been irradiated with 1 MeV electrons at normal incidence and with a 25° tilted angle exhibiting a similar degradation.

high specific power↗

Uncertainty Quantification for Capacity Expansion Planning

This report quantifies the uncertainty in output decisions from a Capacity Expansion Planning (CEP) model. The need to understand how uncertainties within CEP models and modeling assumptions affect Quantities of Interest (QoIs) such as expansion and operating costs, as well as expansion decisions remains an ongoing challenge in scientific research and industrial operations. This area of research is particularly important for models which seek to capture how large networks will evolve and operate under increased sources of variable generation, i.e., higher penetration of renewable technologies such as solar and wind generators. Uncertainty quantification (UQ) of CEP models which estimate expansion costs and decisions, and production cost models which estimate operating costs and dispatch decisions, is a key focus of research at NREL. The Regional Energy Deployment System (ReEDS) represents a state-of-the-art CEP model and considers a range of possible grid evolutions in an attempt to identify key drivers, ramifications, and decisions which contribute to better informed investment and policy decisions. However, research to quantify how uncertainties and model assumptions, such as unit commitment (UC), within ReEDS may be affecting its outputs remains challenging due to to size and complexity of the model

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electric Grid Visualization: Hourly Renewable Generation, Load, Unserved Load, and Locational Marginal Prices during a Heatwave

Visualization of hourly solar and wind generation, load, unserved load, and locational marginal energy prices in the western United States during a July 22-28 heatwave event in 2018, 2058, and 2098. In addition to hourly time series data of each of the parameters, choropleth maps showing the hourly value for each balancing authority are provided.

Climate Change↗

Thermophysical Properties Experimentally Tested for NaCl-KCl-MgCl 2 Eutectic Molten Salt as a Next-Generation High-Temperature Heat Transfer Fluids in Concentrated Solar Power Systems

A new eutectic chloride molten salt, MgCl 2 -KCl-NaCl (wt% 45.98–38.91–15.11), has been recognized as one of the most promising high-temperature heat transfer fluids (HTF) for both heat transfer and thermal storage for the third-generation concentrated solar power (CSP) systems. For the first time, some essential thermophysical properties of this eutectic chloride molten salt needed for basic heat transfer and energy storage analysis in the application of concentrating solar power systems have been experimentally tested and provided as functions of temperature in the range from 450 °C to 700 °C. The studied properties include heat capacity, melting point, heat of fusion, viscosity, vapor pressure, density, and thermal conductivity. The property equations provide essential database for engineers to use to calculate convective heat transfer in concentrated solar receivers, heat exchangers, and thermal storage for concentrated solar power plants.

14 SOLAR ENERGY↗

Design of a 1 MWth Supercritical Carbon Dioxide Primary Heat Exchanger Test System

A new generation of Concentrating Solar Power (CSP) technologies is under development to provide dispatchable renewable power generation and reduce the levelized cost of electricity (LCOE) to 6 cents/kWh by leveraging heat transfer fluids (HTF) capable of operation at higher temperatures and coupling with higher efficiency power conversion cycles. The U.S. Department of Energy (DOE) has funded three pathways for Generation 3 CSP (Gen3CSP) technology development to leverage solid, liquid, and gaseous HTFs to transfer heat to a supercritical carbon dioxide (sCO 2 ) Brayton cycle. Here we present the design and off-design capabilities of a 1 MWth sCO 2 test system that can provide sCO 2 coolant to the primary heat exchangers (PHX) coupling the high-temperature HTFs to the sCO 2 working fluid of the power cycle. This system will demonstrate design, performance, lifetime, and operability at a scale relevant to commercial CSP. A dense-phase high pressure canned motor pump is used to supply up to 5.3 kg/s of sCO 2 flow to the primary heat exchanger at pressures up to 250 bar and temperatures up to 715 °C with ambient air as the ultimate heat sink. Key component requirements for this system are presented in this paper.

14 SOLAR ENERGY↗

Assessment of the impacts of renewable energy variability in long-term decarbonization strategies

To meet the nationally determined contributions proposed by the countries that signed the Paris Agreement, investments must be made in renewable generation technologies such as solar and wind. However, due to their high variability, these technologies pose challenges in terms of meeting demand or generating excess electricity. For this reason, energy system models are designed to capture this variability by considering flexibility technologies. Nevertheless, it is important to note that some energy system models lack integration with other sectors. Therefore, integrated assessment models have been employed to evaluate mitigation strategies, as they endogenously consider the linkages between energy and non-energy sectors. In addition, due to their complexity, these models do not account for the variability of renewable resources. Hence, this research aims to address this issue. Here, this work represents the first attempt to evaluate how the introduction of hourly resolution affects the outcomes of integrated assessment models, specifically focusing on the Global Change Analysis Model (GCAM). We employ a soft-linking approach between the GCAM and the Highway to Renewable Energy Systems model (H2RES, an hourly level energy system model) to accomplish this. The proposed approach is tested using Chile’s Nationally Determined Contributions under different hydrological profiles in the power sector. The results show that it is possible to use the capacity obtained from the Global Change Analysis Model and implement it on an hourly scale. However, the feasibility of implementation depends on high levels of flexibility technologies, such as battery energy storage. When given the choice of investments in renewable sources and flexible technologies, the optimal dispatch of the H2RES model show small differences than those obtained by GCAM-Chile. H2RES differs from GCAM-Chile in approximately 5% for wind and 3% for solar electricity generation in the year 2050. However, feasible integration of significant renewable sources is obtained with relatively high Critical Excess Electricity Production levels, reaching 20% in 2050. This excess electricity is attributed to the necessity for flexible technologies to manage the intermittency of renewables sources when hourly profiles of such sources are considered.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Solar Irradiance Ramp Forecasting Based on All-Sky Imagers

Solar forecasting constitutes a critical tool for operating, producing and storing generated power from solar farms. In the framework of the International Energy Agency’s Photovoltaic Power Systems Program Task 16, the solar irradiance nowcast algorithms, based on five all-sky imagers (ASIs), are used to investigate the feasibility of ASIs to foresee ramp events. ASIs 1–2 and ASIs 3–5 can capture the true ramp events by 26.0–51.0% and 49.0–92.0% of the cases, respectively. ASIs 1–2 provided the lowest (<10.0%) falsely documented ramp events while ASIs 3–5 recorded false ramp events up to 85.0%. On the other hand, ASIs 3–5 revealed the lowest falsely documented no ramp events (8.0–51.0%). ASIs 1–2 are developed to provide spatial solar irradiance forecasts and have been delimited only to a small area for the purposes of this benchmark, which penalizes these approaches. These findings show that ASI-based nowcasts could be considered as a valuable tool for predicting solar irradiance ramp events for a variety of solar energy technologies. The combination of physical and deep learning-based methods is identified as a potential approach to further improve the ramp event forecasts.

14 SOLAR ENERGY↗

Characterization and Understanding of Thermal Transport in Stationary and Moving Particle Beds for Concentrating Solar Power

Concentrating solar power (CSP) coupled with thermal energy storage (TES) is being considered as an appealing solution to deliver stable, dispatchable, and inexpensive electricity generation from renewable solar energy. The heat from the HTF is stored in a TES system that is significantly less expensive and more scalable than electrochemical storage, enabling electricity generation when the sunlight is unavailable. The general concentrating solar thermal technologies are being pushed to higher temperature for higher efficiency and lower cost in a diverse range application in electricity generation (in CSP), industrial heating, and thermochemical fuel productions. Inert and abundant solid particles are becoming increasingly more important for these emerging applications. Heat transfer in both stationary and moving particle beds have been studied for many decades, revealing a great deal of insights on the mechanisms. Yet, there are still several unresolved problems from both fundamental understanding and technological applications points of view. In this Chapter, we will attempt to provide an up-to-date picture of thermal transport in stationary and moving particle beds. In both cases, we will review historical and contemporary developments in the theoretical, computational, and experimental aspects of heat transfer and related behaviors in particle beds. Here, we will discuss both the advancements and limitations of the existing studies and point to future developments towards deeper fundamental understandings and better engineering applications.

14 SOLAR ENERGY↗

Air-stable, earth-abundant molten chlorides and corrosion-resistant containment for chemically-robust, high-temperature thermal energy storage for concentrated solar power

A dramatic reduction in man-made CO 2 emissions could be achieved if the cost of electricity generated from concentrated solar power (CSP) plants could become competitive with fossil-fuel-derived electricity. The solar heat-to-electricity conversion efficiency of CSP plants may be significantly increased (and the associated electricity cost decreased) by operating CSP turbines with inlet temperatures ≥750 °C instead of ≤550 °C, and by using thermal energy storage (TES) at ≥750 °C to allow for rapidly dispatchable and/or continuous electricity production. Unfortunately, earth-abundant MgCl 2 -KCl-based liquids currently being considered as low-cost media for large-scale, high-temperature TES are susceptible to oxidation in ambient air, with associated undesired changes in liquid composition and enhanced corrosion of metal alloys in pipes and tanks containing such liquids. In this paper, alternative high-temperature, earth-abundant molten chlorides that are resistant to oxidation in ambient air are identified via thermodynamic calculations. Here, the oxidation resistance, and corrosion-resistant containment, of such molten chlorides at 750 °C are then demonstrated. Such an air-tolerant strategy, involving chemically-robust, low-cost TES media paired with effective containment materials, provides a critical advance towards the higher-temperature operation of, and lower-cost electricity generation from, CSP plants.

14 SOLAR ENERGY↗

Temperature-Dependent Morphological Evolution during Corrosion of the Ni-20Cr Alloy in Molten Salt Revealed by Multiscale Imaging

Understanding the mechanisms leading to the degradation of alloys in molten salts at elevated temperatures is significant for developing several key energy generation and storage technologies, including concentrated solar and next-generation nuclear power plants. Specifically, the fundamental mechanisms of different types of corrosion leading to various morphological evolution characteristics for changing reaction conditions between the molten salt and alloy remain unclear. Here, in this work, the three-dimensional (3D) morphological evolution of Ni–20Cr in KCl–MgCl 2 is studied at 600 °C by combining in situ synchrotron X-ray and electron microscopy techniques. By further comparing different morphology evolution characteristics in the temperature range of 500–800 °C, the relative rates between diffusion and reaction at the salt–metal interface lead to different morphological evolution pathways, including intergranular corrosion and percolation dealloying. In this work, the temperature-dependent mechanisms of the interactions between metals and molten salts are discussed, providing insights for predicting molten salt corrosion in real-world applications.

36 MATERIALS SCIENCE↗

Near-infrared absorbing acceptor with suppressed triplet exciton generation enabling high performance tandem organic solar cells

Reducing the energy loss of sub-cells is critical for high performance tandem organic solar cells, while it is limited by the severe non-radiative voltage loss via the formation of non-emissive triplet excitons. Herein, we develop an ultra-narrow bandgap acceptor BTPSeV-4F through replacement of terminal thiophene by selenophene in the central fused ring of BTPSV-4F, for constructing efficient tandem organic solar cells. The selenophene substitution further decrease the optical bandgap of BTPSV-4F to 1.17 eV and suppress the formation of triplet exciton in the BTPSV-4F-based devices. The organic solar cells with BTPSeV-4F as acceptor demonstrate a higher power conversion efficiency of 14.2% with a record high short-circuit current density of 30.1 mA cm –2 and low energy loss of 0.55 eV benefitted from the low non-radiative energy loss due to the suppression of triplet exciton formation. We also develop a high-performance medium bandgap acceptor O1-Br for front cells. By integrating the PM6:O1-Br based front cells with the PTB7-Th:BTPSeV-4F based rear cells, the tandem organic solar cell demonstrates a power conversion efficiency of 19%. The results indicate that the suppression of triplet excitons formation in the near-infrared-absorbing acceptor by molecular design is an effective way to improve the photovoltaic performance of the tandem organic solar cells.

14 SOLAR ENERGY↗

Energy Options Analysis Project (Final Report)

This Bear River Band of Rohnerville Rancheria (BRB) Energy Options Analysis Project provides a rigorous and comprehensive near-term renewable energy implementation plan that aligns with the BRB’s long term strategic vision of “zero net annual utility energy consumption.” Final recommendations were arrived at by following four key project phases:A gas and electricity load assessment was conducted for all existing buildings using historic consumption data, and projected loads of new or anticipated buildings using building designs. A renewable energy resource assessment was conducted that estimated the gross generation potential of solar and wind, constrained to areas that could potentially be developed. Other renewable generation technologies were not considered feasible to meet the loads of the BRB. Demand-side efficiency and fuel switching opportunities were identified that can reduce electrical and gas consumption. These opportunities were not integrated into the load assessment in order to provide a conservative implementation plan, but are recommended to be pursued in order to cost-optimize projects during a feasibility assessment. A strategic vision advisory committee was organized and consulted when iterating on the viability of possible projects. These project phases resulted in finalizing the following three solar PV projects for the near term, which also lay the foundation for a future community-scale or multiple-facility microgrid for added resiliency. Additional solar PV on the hillside south of the Tish-Non Community Center. Solar plus battery storage microgrid at the Pump & Play fuel station. Solar PV at the Casino.

14 SOLAR ENERGY↗