Search NASA⌕ Search

SEARCH · Search NASA

Results for “SPECTRAL RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Detection of Gaseous Methane on Pluto

We obtained Pluto's spectrum using the CSHELL echelle spectrograph at NASA's IRTF on Mauna Kea, on 25-26 May 1992, with a spectral resolution of 13,300. The spectral range (5998 - 6018 per centimeter, or 1661.8 - 1666.9 nm) includes the R(0) and the Q(1) - Q(9) lines of the 2v3 band of methane. The resulting spectrum shows the first detection of gaseous methane on Pluto, with a column height of 1.20 (sup +3.15) (sub -0.87) cm-A (3.22 (sup +8.46) (sub -2.34) x 10(exp 19) molecule per square centimeter)).

Young, Leslie↗

On Orbit Commissioning of the Earth Observing System Microwave Limb Sounder (EOS MLS) On the Aura Spacecraft

The Microwave Limb Sounder instrument was launched aboard NASA's EOS AURA satellite in July, 2004. The overall scientific objectives for MLS are to measure temperature, pressure, and several important chemical species in the upper troposphere and stratosphere relevant to ozone processes and climate change. MLS consists of a suite of radiometers designed to operate from 11 8 GHz to 2.5 THz, with two antennas (one for 2.5 THz, the other for the lower frequencies) that scan vertically through the atmospheric limb, and spectrometers with spectral resolution of 6 MHz at spectral line centers. This paper describes the on-orbit commissioning the MLS instrument which includes activation and engineering functional verifications and calibrations.

Earth observing system (EOS)↗

Morphology and Kinematics of Filaments in the Serpens and Perseus Molecular Clouds

We present H(exp 13)CO(exp +) (J= 1-0) and HNC (J= 1-0) maps of regions in Serpens South, Serpens Main, and NGC 1333 containing filaments. We also observe the Serpens regions using H(exp 13)CN (J= 1-0). These dense gas tracer molecular line observations carried out with CARMA have an angular resolution of approximately 7", a spectral resolution of approximately 0.16 km s (exp -1), and a sensitivity of 50-100 mJy beam (exp -1). Although the large-scale structure compares well with the Herschel dust continuum maps, we resolve finer structure within the filaments identified by Herschel. The H(exp 13)CO(exp +) emission distribution agrees with the existing CARMA diazenylium(exp +) (J= 1-0) maps, so they trace the same morphology and kinematics of the filaments. The H(exp 13)CO(exp +) maps additionally reveal that many regions have multiple structures partially overlapping in the line of sight. In two regions, the velocity differences are as high as 1.4 km s(exp -1). We identify eight filamentary structures having typical widths of 0.03 - 0.08 pc in these tracers. At least 50% of the filamentary structures have distinct velocity gradients perpendicular to their major axis, with average values in the range of 4-10 km s(exp -1) pc (exp -1). These findings are in support of the theoretical models of filament formation by 2D inflow in the shock layer created by colliding turbulent cells. We also find evidence of velocity gradients along the length of two filamentary structures; the gradients suggest that these filaments are inflowing toward the cloud core.

Dhabal, Arnab↗

The Third Flight of the Marshall Grazing Incidence X-Ray Spectrometer (MaGIXS-3)

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is the first X-ray slitless imaging spectrograph sounding rocket instrument designed to observe spectrally dispersed soft X-ray images of the solar corona over a wide field-of-view. During the first flight of MaGIXS (MaGIXS-1), occurred on 30 July 2021, several emission lines from coronal structures including X-ray bright points were observed. Further, MaGIXS-1 analysis also demonstrated the successful inversion of overlappograms using robust unfolding algorithms. Given the demonstrated success of MaGIXS-1, the second flight of the instrument with a simplified optical design, MaGIXS-2, is scheduled for 2024 to observe high temperature diagnostic emission lines. Results from MaGIXS-1 discovered dominant missing emission lines near 15A, arising from relatively cool plasma that peaks around 2 MK. This wavelength region hosts several closely spaced satellite lines of Fe XVII, Fe XVI and Fe XV ions, which are expected to be enhanced at lower temperatures and are currently unmodeled in the CHIANTI atomic database. This wavelength region offers one of the most unique diagnostics to measure electron temperature, as well as signatures of equilibrium state of the plasma in active regions, which has not been studied so far. The goal of MaGIXS-3 mission is the to determine coronal heating parameters, such as the spatial and temporal properties of coronal heating events, by measuring discriminating observations, such as electron temperature, effective temperature, density, abundance, and departures from thermal equilibrium of the plasma, by observing the Sun in the SXR wavelength range. To meet this goal, the MaGIXS instrument will be upgraded with a new X-ray telescope mirror that will provide higher spatial and spectral resolution and throughput, allowing for spectral lines to be observed at the relevant spatial and temporal scales. In addition, MaGIXS-3 will also carry The Resolving Inversion Context X-ray Spectrometer (TRICXS), a high dispersion Bragg crystal spectrometer to spectrally resolve the lines near 14.9 to 15.9A, critical to unlock the full diagnostic potential of this wavelength range. Here we will present the preliminary concept design of MaGIXS-3 and discuss the potential observations.

X-ray Imaging↗

The Next Generation Marshall Grazing Incidence X-Ray Spectrometer (MaGIXS) Sounding Rocket Experiments

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a sounding rocket experiment that carries an X-ray slitless imaging spectrograph to observe spectrally dispersed soft X-ray (SXR) images of the solar corona over a wide field-of-view. The first flight of MaGIXS occurred on 30 July 2021, during which several emission lines from coronal structures including X-ray bright points were observed. Analysis of MaGIXS-1 data demonstrated the application of new inversion techniques and opened a new arena of inverting complex spectroheliogram data, which has spatial-spectral information overlapped. The second flight of MaGIXS, with a simplified optical design, is scheduled for 2024. The goal of MaGIXS-2 is to observe high temperature diagnostic emission lines within an active region core. MaGIXS-1 discovered dominant missing emission lines near 15Å wavelength region, which hosts several closely spaced satellite lines of Fe XVII, Fe XVI, and Fe XV ions, arising from relatively cool plasma that peaks near 2MK. These lines are expected to be enhanced at lower temperatures and offers one of the most unique diagnostics to measure electron temperature, as well as signatures of equilibrium state of the plasma in active regions, which has not been studied so far. The science goal of the third sounding rocket flight of MaGIXS is to determine coronal heating parameters, such as the spatial and temporal properties of coronal heating events, by measuring discriminating observations, such as electron temperature, effective temperature, density, abundance, and departures from thermal equilibrium of the plasma, by observing the Sun in the SXR wavelength range. For this, the MaGIXS instrument will be upgraded with a new X-ray telescope mirror that will provide higher spatial and spectral resolution and throughput, allowing for spectral lines to be observed at the relevant spatial and temporal scales. In addition, MaGIXS-3 will also carry The Resolving Inversion Context X-ray Spectrometer (TRICXS), a high dispersion Bragg crystal spectrometer to spectrally resolve the lines near 15Å, critical to unlock the full diagnostic potential of this wavelength range. Here we will present the preliminary concept design of MaGIXS-3 and discuss the potential observations.

X-ray Imaging↗

Present and future CCDs for UV and X-ray scientific measurements

Interacting quantum efficiencies in excess of 50 percent have been demonstrated with CCDs throughout the spectral range 600-9,00 A, and comparable sensitivity is expected to continue to wavelengths as short as a few Angstroms. Nondispersive X-ray spectra throughout the 250-8000 V range have been obtained with an FWHM spectral resolution of 200-250 eV. At present, however, both spectral and spatial resolution is limited at some energies by the diffusion of photogenerated charge into more than one picture element. Progress in reducing charge diffusion is reported, with particular attention given to a theoretical diffusion model and its implications for further improvement.

Janesick, J. R.↗

Vertical resolution and accuracy of atmospheric infrared sounding spectrometers

A theoretical analysis is performed to evaluate the accuracy and vertical resolution of atmospheric profiles obtained with the HIRS/2, GOES I/M, and HIS instruments. In addition, a linear simultaneous retrieval algorithm is used with aircraft observations to validate the theoretical predictions. Both theoretical and observational results clearly indicate that the accuracy and vertical resolution of the retrieval profile would be improved by high spectral resolution and broad spectral coverage of infrared radiance measurements. The HIS is found to possess the equivalent of 11 pieces of temperature- and 9 pieces of water vapor-independent precise measurements. The characteristics for temperature include a vertical resolution of 1-6 km with an accuracy of 1 K and for water vapor a vertical resolution of 0.5-3.0 km with an accuracy of 3 K in dewpoint temperature. The HIS is a factor of 2-3 times better in vertical resolution and a factor of 2 times better in accuracy than the GOES I/M and HIRS/2 filter radiometers.

Huang, Hung-Lung↗

A Description of the Capabilities of AXAF

This talk will describe the Advanced X-ray Astrophysics Facility (AXAF) scientific capabilities, including mirror characteristics, focal plane instruments and gratings. AXAF has an unparalleled subarcsecond spatial resolution, coupled with medium to high spectral resolution, and it will return a totally new picture of the X-ray sky. For the first time we will be able to image in detail complex regions such as the centers of galaxies and globular clusters, and at the same time gather information on the spectral characteristics of the X-ray emission. We will be able to obtain high resolution grating spectra of bright stars and Active Galactic Nuclei (AGN). We will be able to take the deepest look ever possible into the X-ray sky and detect sources at cosmological distances.

Fabbiano, Giuseppina↗

Resolution-enhanced Mapping Spectrometer

A familiar mapping spectrometer implementation utilizes two dimensional detector arrays with spectral dispersion along one direction and spatial along the other. Spectral images are formed by spatially scanning across the scene (i.e., push-broom scanning). For imaging grating and prism spectrometers, the slit is perpendicular to the spatial scan direction. For spectrometers utilizing linearly variable focal-plane-mounted filters the spatial scan direction is perpendicular to the direction of spectral variation. These spectrometers share the common limitation that the number of spectral resolution elements is given by the number of pixels along the spectral (or dispersive) direction. Resolution enhancement by first passing the light input to the spectrometer through a scanned etalon or Michelson is discussed. Thus, while a detector element is scanned through a spatial resolution element of the scene, it is also temporally sampled. The analysis for all the pixels in the dispersive direction is addressed. Several specific examples are discussed. The alternate use of a Michelson for the same enhancement purpose is also discussed. Suitable for weight constrained deep space missions, hardware systems were developed including actuators, sensor, and electronics such that low-resolution etalons with performance required for implementation would weigh less than one pound.

Kumer, J. B.↗

Observations of the electron density spectrum near the sun during spectral broadening transients

We present high-time resolution spectral broadening data for several transients caused by propagating interplanetary disturbances observed inside 20 solar radii. The results show that the shape and level of the ambient near-sun electron density spectrum undergoes abrupt and substantial change during passage of the disturbance. The steepening of the spectrum to near the Kolmogorov value suggests fully-developed inertial-range turbulence in the wake of the interplanetary disturbance.

Woo, R.↗

Second generation spectrograph for the Hubble Space Telescope

The preliminary design for the Space Telescope Imaging Spectrograph (STIS), which has been selected by NASA for definition study for future flight as a second-generation instrument on the Hubble Space Telescope (HST), is presented. STIS is a two-dimensional spectrograph that will operate from 1050 A to 11,000 A at the limiting HST resolution of 0.05 arcsec FWHM, with spectral resolutions of 100, 1200, 20,000, and 100,000 and a maximum field-of-view of 50 x 50 arcsec. Its basic operating modes include echelle model, long slit mode, slitless spectrograph mode, coronographic spectroscopy, photon time-tagging, and direct imaging. Research objectives are active galactic nuclei, the intergalactic medium, global properties of galaxies, the origin of stellar systems, stelalr spectral variability, and spectrographic mapping of solar system processes.

Woodgate, B. E.↗

The role of spatial, spectral and radiometric resolution on information content

The results of a factorial experiment to evaluate the effects of spatial, spectral, and radiometric resolution on training-data spectral separability and classification accuracy are reported. Aircraft scanner data from five flightlines at 19.8 km over California including croplands, rangeland, forest, water, and urban areas were systematically degraded over a range approximately from Landsat MSS to Thematic Mapper specifications. Reference data were collected on the ground and from aerial photography. The degradations, training-site delineation, data-analysis procedures, and accuracy-assessment techniques are described; the results are presented in tables and graphs and discussed. It is found that while accuracy was increased by higher spectral resolution in 70 percent of the cases and uniformly by increased radiometric resolution, it was decreased by higher spatial resolution. This phenomenon is attributed to classification methods.

Buis, J. S.↗

Conical focusing crystal spectrometers for cosmic X-ray astronomy

A crystal spectrometer for rocket and satellite experiments is described. Parallel X rays from a stellar object are reflected at constant angle by Bragg crystals arranged around the sector of a cone so that a single wavelength is brought to a focus onto the axis of the cone. The aberrations produced when this array is tilted to change the wavelength are considered. It is shown that these are minimized by moving cone and detector in a nearly theta to two-theta motion and by using a small-angle sector. In a specific design for a satellite instrument using LiF crystal to observe a spectral region including the iron lines at 1.9 A, a spectral resolution of 3 mA over a spectral range of 1.6-2.1 A can be obtained, with the cosmic-ray background rate, and hence the time to detect a weak line decreased by a factor 80 compared to a flat crystal spectrometer. Examples of performance for a low energy rocket experiment are also given.

Woodgate, B. E.↗

Lyman-alpha rocket spectra and models of the quiet and active solar chromosphere based on partial redistribution diagnostics

Absolute intensity Lyman-alpha profiles with a spatial resolution of 0.8 min and a spectral resolution of 50 mA were obtained for network and cell regions in the quiet sun, umbral and penumbral areas of a sunspot, two plages, and a quiescent prominence of the limb. Weak limb brightening shown by the Lyman-alpha cores and wings are consistent with predictions derived from partial redistribution line transfer calculations. Through use of a comoving two-level partial redistribution code which conserves mass flux, unequal red and blue Lyman-alpha peak intensities may be interpreted as flow velocities near 20,000 K. Outflows in the plages and downflows in the network are also noted. A model of a mean quiet sun chromosphere consistent with the Lyman-alpha integrated intensity, the Lyman continuum slope, and the millimeter continuum is presented.

Basri, G. S.↗

The pointable multispectral linear array system and the large format camera for early 1980 shuttle payloads

Design options are described for the multispectral linear arrays which will provide data and facilities beyond those obtained by LANDSAT 1, 2, 3, and D (the thematic mapper) are considered. The features, uses, and risks of a 10M fine resolution pointable imager, a 15M/30M dual resolution pointable imager, a 30M selectable spectral resolution pointing imager, a 30M electronically pointable multi-temporal sampler, and a 40M/80M mixed resolution imager are described. A large format camera scheduled for 1981 shuttle launch which can obtain high spatial ground resolution (approximately 10M), a relative position accuracy of plus or minus 14M, and a relative heightening accuracy, by virtue of stereographic coverage, of between 7 and 28M depending on the base-to-height ratio used. A potential problem of the system is that it will orbit in the shuttle.

Slater, P. N.↗

Space telescope scientific instruments

The paper describes the Space Telescope (ST) observatory, the design concepts of the five scientific instruments which will conduct the initial observatory observations, and summarizes their astronomical capabilities. The instruments are the wide-field and planetary camera (WFPC) which will receive the highest quality images, the faint-object camera (FOC) which will penetrate to the faintest limiting magnitudes and achieve the finest angular resolution possible, and the faint-object spectrograph (FOS), which will perform photon noise-limited spectroscopy and spectropolarimetry on objects substantially fainter than those accessible to ground-based spectrographs. In addition, the high resolution spectrograph (HRS) will provide higher spectral resolution with greater photometric accuracy than previously possible in ultraviolet astronomical spectroscopy, and the high-speed photometer will achieve precise time-resolved photometric observations of rapidly varying astronomical sources on short time scales.

Leckrone, D. S.↗

Optical design of the ATMOS Fourier transform spectrometer

The optical system design of the ATMOS Fourier transform spectrometer to be operated from Spacelab for the measurement of stratospheric trace molecules is described. The design contains features which can achieve the required fringe contrast of 80% and spectral resolution of 0.02/cm over a spectral range of 2-16 microns. In particular, the design is based on the following features which alleviate the usual requirements for alignment precision: (1) 'cat's eye' mirror configuration in the two arms of the interferometer for retroreflection stability, (2) tilt-compensated system of beamsplitter, compensator, and fold mirrors for wavefront directional stability, (3) paraboloidal 'cat's eye' primary mirror for wavefront stability against shear, (4) rotatable compensator for matching chromatic dispersion, and (5) wedged refractive components to avoid channel spectra due to the Fabry-Perot effect.

Abel, I. R.↗