Search NASA⌕ Search

SEARCH · Search NASA

Results for “SPECTROGRAPH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

The star identification, pointing and tracking system of UVSTAR, an attached payload instrument system for the Shuttle Hitchhiker-M platform

We describe an algorithm for star identification and pointing/tracking of a spaceborne electro-optical system and simulation analyses to test the algorithm. The algorithm will be implemented in the guiding system of UVSTAR, a spectrographic telescope for observations of astronomical and planetary sources operating in the 500-1250 A waveband at approximately 1 A resolution. The experiment is an attached payload and will fly as a Hitchhiker-M payload on the Shuttle. UVSTAR includes capabilities for independent target acquisition and tracking. The spectrograph package has internal gimbals that allow angular movement of plus or minus 3 deg from the central position. Rotation about the azimuth axis (parallel to the Shuttle z axis) and elevation axis (parallel to the Shuttle x axis) will actively position the field of view to center the target of interest in the fields of the spectrographs. The algorithm is based on an on-board catalog of stars. To identify star fields, the algorithm compares the positions of stars recorded by the guiding imager to positions computed from the on-board catalog. When the field has been identified, its position within the guiding imager field of view can be used to compute the pointing corrections necessary to point to a target of interest. In tracking mode, the software uses the past history to predict the quasi-periodic attitude control motions of the shuttle and sends pointing commands to cancel the motion and stabilize UVSTAR on the target. The guiding imager (guider) will have an 80-mm focal length and f/1.4 optics giving a field of view of 6 deg x 4.5 deg using a 385 x 288 pixel intensified CCD. It will be capable of providing high accuracy (better than 2 arc-sec) attitude determination from coarse (6 deg x 4.5 deg) initial knowledge of the pointing direction; and of pointing toward the target. It will also be capable of tracking at the same high accuracy with a processing time of less than a few hundredths of a second.

Decarlo, Francesco↗

LOITA: Lunar Optical/Infrared Telescope Array

LOITA (Lunar Optical/Infrared Telescope Array) is a lunar-based interferometer composed of 18 alt-azimuth telescopes arranged in a circular geometry. This geometry results in excellent uv coverage and allows baselines up to 5 km long. The angular resolution will be 25 micro-arcsec at 500 nm and the main spectral range of the array will be 200 to 1100 nm. For infrared planet detection, the spectral range may be extended to nearly 10 mu m. The telescope mirrors have a Cassegrain configuration using a 1.75 m diameter primary mirror and a 0.24 m diameter secondary mirror. A three-stage (coarse, intermediate, and fine) optical delay system, controlled by laser metrology, is used to equalize path lengths from different telescopes to within a few wavelengths. All instruments and the fine delay system are located within the instrument room. Upon exiting the fine delay system, all beams enter the beam combiner and are then directed to the various scientific instruments and detectors. The array instrumentation will consist of CCD detectors optimized for both the visible and infrared as well as specially designed cameras and spectrographs. For direct planet detection, a beam combiner employing achromatic nulling interferometry will be used to reduce star light (by several orders of magnitude) while passing the planet light. A single telescope will be capable of autonomous operation. This telescope will be equipped with four instruments: wide field and planetary camera, faint object camera, high resolution spectrograph, and faint object spectrograph. These instruments will be housed beneath the telescope. The array pointing and control system is designed to meet the fine pointing requirement of one micro-arcsec stability and to allow precise tracking of celestial objects for up to 12 days. During the lunar night, the optics and the detectors will be passively cooled to 70-80 K temperature. To maintain a continuous communication with the earth a relay satellite placed at the L4 libration point will be used in conjunction with the Advanced Tracking and Data Relay Satellite System (ATDRSS). Electrical power of about 10 kW will be supplied by a nuclear reactor based on the SP-100 technology. LOITA will be constructed in three phases of six telescopes each. The total mass of the first operational phase is estimated at 58,820 kg. The cost of the fully operational first phase of the observatory is estimated at $8.9 billion. LOITA's primary objectives will be to detect and characterize planets around nearby stars (up to ten parsec away), study physics of collapsed stellar objects, solar/stellar surface features and the processes in nuclear regions of galaxies and quasars. An interferometric array such as LOITA will be capable of achieving resolutions three orders of magnitude greater than Hubble's design goal. LOITA will also be able to maintain higher signal to noise ratios than are currently attainable due to long observation times available on the moon.

Source record↗

A study of low mass x-ray binaries

The entire effort under this contract during the period through January 1992 was devoted to a study of the cost and schedule required to put an upgraded Aries payload on the ASTRO-SPAS carrier provided by the German space agency, DARA. The ASTRO-SPAS is flown on the Space Shuttle, deployed by the crew for 5 to 7 days of free-flying observations and then recovered and returned to Earth. The spectrograph was to be provided by a collaboration involving the Lockheed Palo Alto Research Laboratory (LPARL), the Center for Astrophysics and Space Astronomy (CASA) at the U. of Colorado and the Mullard Space Science Laboratory (MSSL) in England. The payload for the ASTRO-SPAS mission included our own spectrograph and an instrument provided by Dr. Joachim Trumper of the Max Planck Institute (MPI) in Garching, Germany. A meeting was held in late July, 1991 with German scientists, DARA representatives and MBB, the ASTRO-SPAS spacecraft contractor. Sufficient information was exchanged to allow us to complete the study and the name LEXSA (Low Energy X-ray Spectrograph on ASTRO-SPAS) was given to our instrument and HERTA (High Energy x-Ray Telescope on ASTR0-SPAS) to the German instrument. The combination was called SPECTRO-SPAS. On October 1, 1991 CASA and LPARL submitted a cost and brief technical proposal to NASA on results of the study. The total cost over 4 fiscal years was 6.16 M dollars including CASA costs. NASA Headquarters was briefed on 3 October on details of the proposal. They found our costs reasonable, but indicated that the NASA FY '92 budget is extremely tight, they could not readily identify where the -S2.3M for LEXSA could be found and it was not clear that FY '93 would improve.

Catura, Richard C.↗

Ultraviolet observations of the structure and dynamics of an active region at the limb

The structure and dynamics of active region NOAA 7260 at the limb have been studied using ultraviolet spectra and spectroheliograms obtained during the eighth rocket flight of the Naval Research Laboratory's High Resolution Telescope an Spectrograph (HRTS). The instrument configuration included a narrow-bandpass spectroheliograph to observe the Sun in the lines of C IV lambda 550 and a tandem-Wadsworth mount spectrograph to record the profiles of chromospheric transition region and coronal lines in the 1850-2670 A region. The combination of high spatial resolution and high spectral purity C IV slit jaw images with ultraviolet emission-line spectra corresponding allows examination of a variety of active region phenomena. A time series of spectroheliograms shows large-scale loop systems composed of fine-scale threads with some extending up to 100 Mm above the limb. The proper motion of several supersonic features, including a surge were measured. The accelerated plasmas appear in several different geometries and environments. Spectrograph exposures were taken with the slit positioned at a range of altitudes above the limb and provide a direct comparison between coronal, transition region and chromospheric emission line profiles. The spectral profiles of chromospheric and transition region emission lines show line-of-sight velocities up to 70 km/s. These lower temperature, emission-line spectra show small-scale spatial and velocity variations which are correlated with the threadlike structures seen in C IV. Coronal lines of Fe XII show much lower velocities and no fine structure.

Korendyke, C. M.↗

The O IV and S IV intercombination lines in solar and stellar ultraviolet spectra

New calculations of O IV electron density diagnostic emission-line ratios involving the 1399.8, 1401.2, 1404.8, and 14076.4 A transitions are presented. A comparison of these calculations with observational data from a quiet solar region, a sunspot, and an active region obtained with the High Resolution Telescope and Spectrograph (HRTS), two flares observed with the SO82B spectrograph on board Skylab, and Hubble Space Telescope (HST) observations by the Goddard High Resolution Spectrograph (GHRS) of Capella, gives good results using the ratio R(sub 1) = I(1407.4 A)/I(1401.2 A). However, the electron density obtained using the ratio R(sub 2) = I(1407.4 A)/I(1404.8 A) is often an order of magnitude smaller. The O IV 1404.8 A line is blended with the S IV 1404.8 A line, and we investigate whether this ratio may still be used as a density diagnostic if the S IV 1406.1 A line intensity is used to correct for the presence of S IV 1404.8 A, using previous S IV calculations by Dufton et al. We still find systematic differences compared to density determinations from line ratios that do not involve the O IV 1404.8 A line, which we suggest are due to errors in earlier theoretical calculations of the S IV atomic data, and also possibly to previously unconsidered fluorescent pumping of the upper level of the S IV 1404.8 A transition.

Cook, J. W.↗

Radial Velocity Detection of Extra-Solar Planetary Systems

The McDonald Observatory Planetary Search (MOPS) was designed to search for Jovian-mass planets in orbit around solar-type stars by making high-precision measurements of the Radial Velocity (RV) of a star, to attempt to detect the reflex orbital motion of the star around the star-planet barycenter. In our solar system, the velocity of the Sun around the Sun-Jupiter barycenter averages 12.3 m/ s. The MOPS survey started operation in September 1987, and searches 36 bright, nearby, solar-type dwarfs to 10 m/s precision. The survey was started using telluric O2 absorption lines as the velocity reference metric. Observations use the McDonald Observatory 2.7-m Harlan Smith Telescope coude spectrograph with the six-foot camera. This spectrograph configuration isolates a single order of the echelle grating on a Texas Instruments 800 x 800 CCD. The telluric line method gave us a routine radial velocity precision of about 15 m/s for stars down to about 5-th magnitude. However, the data obtained with this technique suffered from some source of long-term systematic errors, which was probably the intrinsic velocity variability of the terrestrial atmosphere, i.e. winds. In order to eliminate this systematic error and to improve our overall measurement precision, we installed a stabilized I2 gas absorption cell as the velocity metric for the MOPS in October 1990. In use at the telescope, the cell is placed directly in front of the spectrograph entrance slit, with starlight passing through the cell. The use of this sealed stabilized I2 cell removes potential problems with possible long-term drifts in the velocity metric. The survey now includes a sample of 36 nearby F, G, and K type stars of luminosity class V or IV-V.

Cochran, William D.↗

Comparison of Stress Relief Procedures for Cryogenic Aluminum Mirrors

The Infrared Multi-Object Spectrograph (IRMOS) is a facility instrument for the Kitt Peak National Observatory Mayall Telescope (3.8 meter) and an engineering prototype for a potential design for the Next Generation Space Telescope/Multi-Object Spectrograph. IRMOS is a low-to mid-resolution (R = lambda/delta-lambda = 300-3800), near-IR (0.8-2.5 micron) spectrograph which produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arcmin field of view using a commercial MEMS multimirror array device. The instrument operating temperature is 80 K and the design is athermal --- the optical bench and mirrors are machined from aluminum 6061-T651. In spite of its baseline mechanical stress relief, aluminum 6061-T651 harbors some residual stress, which, unless relieved during fabrication, may relieve and distort mirror figure to unacceptable levels at the operating temperature. Other cryogenic instruments using aluminum mirrors for both ground-based and space IR astronomy have employed a variety of heat treatment formulae, with mixed results. We present the results of a test program designed to empirically determine the best stress relief procedure for the IRMOS mirrors. Identical test mirrors with spherical and flat optical prescriptions are processed with five different heat treatment formulae from the literature and compared to samples with out any additional processing. After figuring via diamond turning, the mirrors are tested for figure error and radius of curvature at room temperature and at 80 K for several thermal cycles. The heat treatment procedure for the mirrors that yielded the least and most repeatable change in figure error and radius is applied to the IRMOS mirror blanks. We correlate the results of our optical testing with heat treatment and metallographic data.

Ohl, Raymond G.↗

Design, Fabrication, Optical Testing, and Performance of Diamond Machined Aspheric Mirrors for Ground-Based Near-IR Astronomy

Challenges in fabrication and testing have historically limited the choice of surfaces available for the design of reflective optical instruments. Spherical and conic mirrors are common, but, for future science instruments, more degrees of freedom are necessary to meet challenging performance and packaging requirements. These instruments will be composed of unusual aspheres located far off-axis with large spherical departure, and some designs will require asymmetric surface profiles. In particular, single-surface astigmatism correction in spectrographs necessitates a toroidal surface, which lacks an axis of rotational symmetry. We describe the design, fabrication, optical testing, and performance of three rotationally symmetric, off-axis, aspheric mirrors and one toroidal, off-axis, biconic camera mirror on aluminum substrates for the Infrared Multi-Object Spectrograph (IRMOS) instrument. IRMOS is a facility instrument for the Kitt Peak National Observatory's Mayall Telescope (3.8 m) and an engineering prototype for a possible design of the Next Generation Space Telescope/Multi-Object Spectrograph. The symmetric mirrors range in aperture from 94x86 mm to 286x269 mm and in f-number from 0.9 to 2.4. They are various off-axis, convex and concave, prolate and oblate ellipsoids. The concave biconic mirror has a 94x76 mm aperture, Rx=377 mm, kx=0.0778, Ry=407 mm, and ky=0.1265 and is decentered. by -2 mm in x and 227 mm in y. The mirrors have an aspect ratio of approximately 4:1. The surface error fabrication tolerances are less than 63.3 nm RMS figure error and less than 10 nm RMS microroughness. The mirrors are attached to the instrument bench via a semi-kinematic, integral flexure mount. We describe mirror design, diamond machining, the results of figure testing using computer-generated holograms, and imaging and scattered light modeling and performance.

Ohl, Raymond G.↗

Calibration of the Shuttle Ozone Limb Sounding Experiment (SOLSE) and the Limb Ozone Retrieval Experiment (LORE)

The calibration and characterization of two new instruments designed to retrieve ozone profiles into the lower stratosphere will be presented. These instruments will fly as a single payload on the Space Shuttle Columbia currently scheduled to lift off July 11, 2002. The purpose of SOLSE (Shuttle Ozone Limb Sounding Experiment) and LORE (Limb Ozone Retrieval Experiment) is to provide a thorough test of the limb ozone retrieval technique, which is being employed on several satellite instruments currently deployed or planned for deployment in the near future. OSIRIS (Optical Spectrograph and Infrared Imager System) and SCIAMACHY (Scanning Imaging Absorption Spectrometer for Atmospheric Chartography) are already in orbit, while OMPS (the Ozone Mapping and Profiler Suite) is planned as the primary US ozone monitoring instrument in the next decade.. SOLSE is a Czerny-Turner spectrograph utilizing a 1k x 1k cooled CCD at the focal plane and covering the spectral range of 310-380 nm in the ultraviolet and 535-865 nm in the visible to near infrared. LORE is a 5 channel filter radiometer with center band wavelengths of 322, 350, 603, 675, and 1000 nm. The focus of this paper will be on measurements of the SOLSE spectrograph performance in the limb-viewing configuration including stray light rejection, spatial and spectral resolution and absolute radiometric response.

Janz, S. J.↗

Small Business Innovations

Under a Small Business Innovation Research (SBIR) contract to Kennedy Space Center, EIC Laboratories invented a Raman Spectrograph with fiber optic sampling for space applications such as sensing hazardous fuel vapors and making on-board rapid analyses of chemicals and minerals. Raman spectroscopy is a laser-based measurement technique that provides through a unique vibrational spectrum a molecular 'fingerprint,' and can function in aqueous environments. EIC combined optical fiber technology with Raman methods to develop sensors that can be operated at a distance from the spectrographic analysis instruments and the laser excitation source. EIC refined and commercialized the technology to create the Fiber Optic Raman Spectrograph and the RamanProbe. Commercial applications range from process control to monitoring hazardous materials.

Source record↗

The Star Formation History of Orion and its Environs

During the period of performance, we have obtained the following observations and carried out the analysis of the Orion associations itemized below. Optical Photometry: The Quest camera that had been damaged by lightning on Sept. 2001 was reconfigured to use 10 chips and only 3 filters instead of the original 4 but retaining its spatial coverage of 2.3deg wide in declination. During the Winter and Fall 2002 observing campaigns, we obtained multifilter photometry using the Quest camera on the 1mt Schmidt of the Venezuelan National Observatory, to continue the survey of the Orion clouds. In the Winter 2002 season, we obtained photometry for 10 scans at DEC=+5, 7 scans at DEC=-5. Several additional scans at DEC=-3 were obtained during the Fall 2002 observing campaign. Slit spectroscopy of bright candidates: During 2002 spectra for some 235 candidate PMS stars were obtained with the FAST spectrograph at the SAO 1.5m telescope in Mt. Hopkins. These objects, all brighter than V=16, are located in two strips centered at DEC=+l and -5, and spanning from RA=5h-6h. The spectra are being analyzed. Multifiber spectroscopy: Spectroscopy for our fainter (V less than or equal to 16) candidates has not kept pace with our spectroscopy of brighter candidates, because of the delay in the commissioning of the Hectospec and Hectoechelle multi-object spectrographs at the new 6.5m MMT. We obtained some data with the Hydra spectrograph on the WIYN telescope: Feb 1-4, 2002. Time granted to the project: "A Large Scale Survey of the Low-Mass Young Population in the Orion OB1 Association" (P.I.: C. Briceno). Three half-nights (we used the first half of the night, the second half of the night was used with the Mini-Mosaic imager by another team). Only the first half night was clear. We observed 3 fields centered in a 2.3 deg wide strip centered at DEC=-1 and spanning RA=Sh to 6h. A total of 250 spectra were obtained for the same number of candidate PMS stars. Nov. 13-15, 2002. Time granted to the project "Cluster survey of protoplanetary disk evolution", (P.I.: A. Sicilia-Aguilar). Clear weather throughout. We obtained spectra for some 200 candidate PMS stars in 3 fields located in a 2.3 deg wide strip centered at DEC=+l and spanning from RA=5h20m to 5h35m. Data for both observing runs is partially reduced and is being analyzed. U photometry: During Nov.29-Dec.4, 2002 we were granted time with the 4-shooter CCD Mosaic Camera at the SAO 1.2m telescope, to obtain U-band photometry of a subset of the newly identified T Tauri stars in the strip centered at DEC=-1. This sample is composed of strong H(alpha) emitting PMS stars (Classical T Tauri stars) located mostly in the Orion OB lb association, around the Orion Belt area. Our data will be combined with our calibration of the U-band excess (Gullbring et al. 1998) to derive mass accretion rates. Because of bad weather we observed only 20 stars during 1.5 clear nights. Near IR photometry: During Dec. 14-19, 2002 we used the IR Camera on the SAO 1.2m telescope, to obtain L-band photometry of a set of 17 the newly identified Orion OB 1a and 1b stars, in order to look for IR excess emission coming from the hotter inner parts of circumstellar disks. Again, mediocre weather prevented a larger set to be observed. These stars were also observed with the OSCIR mid-IR camera on Gemini North during later 2001. Our goal is to construct SEDs from the visual out to the mid-IR (by combining our optical/IR data with 2MASS JHK magnitudes) in order to explore disk dissipation at the critical ages of 5-10 Myr spanned by these stars.

Calvet, Nuria↗

Narrow-band EUV Multilayer Coating for the MOSES Sounding Rocket

The Multi-order Solar EUV Spectrograph (MOSES) is a slitless spectrograph designed to study solar He II emission at 303.8 Angstroms, to be launched on a sounding rocket payload. One difference between MOSES and other slitless spectrographs is that the images are recorded simultaneously at three spectral orders, m = -1,0, +l. Another is the addition of a narrow-band multilayer coating on both the grating and the fold flat, which will reject out-of-band lines that normally contaminate the image of a slitless instrument. The primary metrics f a the mating were high peak reflectivity and suppression of Fe XV and XVI emission lines at 284 Angstroms and 335 Angstroms, respectively. We chose B4C/Mg2Si for our material combination since it provides better values for all three metrics together than the other leading candidates Si/Ir, Si/B4C or Si/SiC. Measurements of witness flats at NIST indicate the peak reflectivity at 303.6 is 38.5% for a 15 bilayer stack, while the suppression at 284 Angstroms, is 4.5x and at 335 Angstroms is 18.3x for each of two reflections in the instrument. We present the results of coating the MOSES flight gratings and fold flat, including the spectral response of the fold flat and grating as measured at NIST's SURF III and Brookhaven's X24C beamline.

Owens, Scott M.↗

Remote Pulsed Laser Raman Spectroscopy System for Detecting Qater, Ice, and Hydrous Minerals

For exploration of planetary surfaces, detection of water and ice is of great interest in supporting existence of life on other planets. Therefore, a remote Raman spectroscopy system was demonstrated at NASA Langley Research Center in collaboration with University of Hawaii for detecting ice-water and hydrous minerals on planetary surfaces. In this study, a 532 nm pulsed laser is utilized as an excitation source to allow detection in high background radiation conditions. The Raman scattered signal is collected by a 4-inch telescope positioned in front of a spectrograph. The Raman spectrum is analyzed using a spectrograph equipped with a holographic super notch filter to eliminate Rayleigh scattering, and a holographic transmission grating that simultaneously disperses two spectral tracks onto the detector for higher spectral range. To view the spectrum, the spectrograph is coupled to an intensified charge-coupled device (ICCD), which allows detection of very weak Stokes line. The ICCD is operated in gated mode to further suppress effects from background radiation and long-lived fluorescence. The sample is placed at 5.6 m from the telescope, and the laser is mounted on the telescope in a coaxial geometry to achieve maximum performance. The system was calibrated using the spectral lines of a Neon lamp source. To evaluate the system, Raman standard samples such as calcite, naphthalene, acetone, and isopropyl alcohol were analyzed. The Raman evaluation technique was used to analyze water, ice and other hydrous minerals and results from these species are presented.

Garcia, Christopher S.↗

First Results from EUNIS-06

The Extreme Ultraviolet Normal-Incidence Spectrograph (EUNIS) sounding rocket experiment successfully completed its first flight on 12 April 2006 from White Sands Missile Range, obtaining 145 science images in each of two wavelength channels. EUNIS is designed to investigate the energetics of the solar corona and hotter transition region through high-resolution imaging spectroscopy with a rapid (2-3 second) cadence. The two independent optical systems of EUNIS simultaneously record spectra over two passbands (170-205 Angstroms and 300-370 Angstroms), each spatially resolved along slit lengths of about 660 arcsec. The longwave channel includes He II 304 Angstroms and strong lines from Fe XI-XVI. The shortwave passband has a sequence of very strong Fe IX-XIII lines. Together, the EUNIS telescopes furnish a wide range of temperature and density diagnostics and enables underflight calibration of instrumental passbands on the SOHO, TRACE, Solar-B and STEREO missions. We present an overview of the science images from the first flight with emphasis on transient phenomena. The target was active region NOAA 10871 and adjacent quiet areas. Spectra were recorded with exposure times as short as 0.1 s, demonstrating that EUNIS is the most sensitive solar EUV spectrograph in operation, with over 100 times the throughput of its predecessor, the Solar Extreme ultraviolet Research Telescope and Spectrograph (SERTS). EUNIS is supported by the NASA Heliophysics Division's Solar & Heliospheric Physics Supporting Research and Technology and Low Cost Access to Space Program.

Rabin, Douglas M.↗

The Importance of High Spatial and Appropriate Spectral Resolution Spectroscopy

Many diverse astronomical sources are resolved with diffraction-limited large telescopes. Application of appropriate dispersion spectroscopy unveils much information on the physics of these objects ranging from gamma ray bursters in host galaxies, star-formation regions and central engines in nearby galaxies, structures in galactic nebulae, resolved binaries with mass exchange, extended winds of massive stars, protoplanetary systems, and comets, asteroids and planets within our own solar system. Active optics and interferometers coupled with spectrographs can provide near-diffraction-limited spectroscopy from the ground but only longward of one micron. Below one micron, and certainly below 6000A, we must turn to space-based large telescopes equipped with spectrographs capable of providing spatially diffraction-limited spectroscopy of astronomical sources. Examples will be presented from the HST/STIS, ground-based and other instruments on science that has been accomplished. Suggestions will be made of what might be possible, and limitations thereof, with future large monolithic, multiple mirror or interferometric telescopes equipped with spectrographs that would be matched to the diffraction limit of the telescope.

Gull, Theodore↗

EUNIS-07: First Look

The Extreme Ultraviolet Normal Incidence Spectrograph (EUNIS) sounding rocket instrument is a two-channel imaging spectrograph that observes the solar corona with high spectral resolution and a rapid cadence made possible by unprecedented sensitivity. EUNIS flew for the first time on 2006 April 12 (EUNIS-06), returning over 140 science exposures at a cadence of 2.1 s; each exposure comprises six 1K x 1K active pixel sensor (APS) images, three for each wavelength channel (170-205 $\AA$ and 300-370 $\AA$). Analysis of EUNIS-06 data has so far shed new light on the nature of coronal bright points, cool transients, and coronal loop arcades and has enabled calibration updates for TRACE and SOHO's CDS and EIT. EUNIS flew successfully again on 2007 November 6 (EUNIS-07). Because the APS's were operated in video rather than snapshot mode, a faster cadence of 1.3 s was possible (97% duty cycle), resulting in 276 science exposures. We present an overview of the EUNIS-07 spectra and describe the coordinated observing program executed by the Hinode Extreme ultraviolet Imaging Spectrograph (EIS) that will, in conjunction with the absolute radiometric calibration of EUNIS-07, result in the first on-orbit radiometric calibration of EIS. EUNIS data are freely available to the solar physics community. EUNIS is supported by the NASA Heliophysics Division through its Low Cost Access to Space Program in Solar and Heliospheric Physics.

Rabin, Douglas M.↗

The Hubble Space Telescope: UV, Visible, and Near-Infrared Pursuits

The Hubble Space Telescope continues to push the limits on world-class astrophysics. Cameras including the Advanced Camera for Surveys and the new panchromatic Wide Field Camera 3 which was installed nu last year's successful servicing mission S2N4,o{fer imaging from near-infrared through ultraviolet wavelengths. Spectroscopic studies of sources from black holes to exoplanet atmospheres are making great advances through the versatile use of STIS, the Space Telescope Imaging Spectrograph. The new Cosmic Origins Spectrograph, also installed last year, is the most sensitive UV spectrograph to fly io space and is uniquely suited to address particular scientific questions on galaxy halos, the intergalactic medium, and the cosmic web. With these outstanding capabilities on HST come complex needs for laboratory astrophysics support including atomic and line identification data. I will provide an overview of Hubble's current capabilities and the scientific programs and goals that particularly benefit from the studies of laboratory astrophysics.

Wiseman, Jennifer↗

Multipurpose Hyperspectral Imaging System

A hyperspectral imaging system of high spectral and spatial resolution that incorporates several innovative features has been developed to incorporate a focal plane scanner (U.S. Patent 6,166,373). This feature enables the system to be used for both airborne/spaceborne and laboratory hyperspectral imaging with or without relative movement of the imaging system, and it can be used to scan a target of any size as long as the target can be imaged at the focal plane; for example, automated inspection of food items and identification of single-celled organisms. The spectral resolution of this system is greater than that of prior terrestrial multispectral imaging systems. Moreover, unlike prior high-spectral resolution airborne and spaceborne hyperspectral imaging systems, this system does not rely on relative movement of the target and the imaging system to sweep an imaging line across a scene. This compact system (see figure) consists of a front objective mounted at a translation stage with a motorized actuator, and a line-slit imaging spectrograph mounted within a rotary assembly with a rear adaptor to a charged-coupled-device (CCD) camera. Push-broom scanning is carried out by the motorized actuator which can be controlled either manually by an operator or automatically by a computer to drive the line-slit across an image at a focal plane of the front objective. To reduce the cost, the system has been designed to integrate as many as possible off-the-shelf components including the CCD camera and spectrograph. The system has achieved high spectral and spatial resolutions by using a high-quality CCD camera, spectrograph, and front objective lens. Fixtures for attachment of the system to a microscope (U.S. Patent 6,495,818 B1) make it possible to acquire multispectral images of single cells and other microscopic objects.

Mao, Chengye↗