Search NASA⌕ Search

SEARCH · Search NASA

Results for “STEAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Computational Analyses in Support of Sub-scale Diffuser Testing for the A-3 Facility: Steady Predictions - Part 1

Simulation technology can play an important role in rocket engine test facility design and development by assessing risks, providing analysis of dynamic pressure and thermal loads, identifying failure modes and predicting anomalous behavior of critical systems. Advanced numerical tools assume greater significance in supporting testing and design of high altitude testing facilities and plume induced testing environments of high thrust engines because of the greater inter-dependence and synergy in the functioning of the different sub-systems. This is especially true for facilities such as the proposed A-3 facility at NASA SSC because of a challenging operating envelope linked to variable throttle conditions at relatively low chamber pressures. Facility designs in this case will require a complex network of diffuser ducts, steam ejector trains, fast operating valves, cooling water systems and flow diverters that need to be characterized for steady state performance. In this paper, we will demonstrate with the use of CFD analyses s advanced capability to evaluate supersonic diffuser and steam ejector performance in a sub-scale A-3 facility at NASA Stennis Space Center (SSC) where extensive testing was performed. Furthermore, the focus in this paper relates to modeling of critical sub-systems and components used in facilities such as the A-3 facility. The work here will address deficiencies in empirical models and current CFD analyses that are used for design of supersonic diffusers/turning vanes/ejectors as well as analyses for confined plumes and venting processes. The primary areas that will be addressed are: (1) supersonic diffuser performance including analyses of thermal loads (2) accurate shock capturing in the diffuser duct; (3) effect of turning duct on the performance of the facility (4) prediction of mass flow rates and performance classification for steam ejectors (5) comparisons with test data from sub-scale diffuser testing and assessment of confidence levels in CFD based flowpath modeling of the facility. The analyses tools used here expand on the multi-element unstructured CFD which has been tailored and validated for impingement dynamics of dry plumes, complex valve/feed systems, and high pressure propellant delivery systems used in engine and component test stands at NASA SSC. The analyses performed in the evaluation of the sub-scale diffuser facility explored several important factors that influence modeling and understanding of facility operation such as (a) importance of modeling the facility with Real Gas approximation, (b) approximating the cluster of steam ejector nozzles as a single annular nozzle, (c) existence of mixed subsonic/supersonic flow downstream of the turning duct, and (d) inadequacy of two-equation turbulence models in predicting the correct pressurization in the turning duct and expansion of the second stage steam ejectors. The procedure used for modeling the facility was as follows: (i) The engine, test cell and first stage ejectors were simulated with an axisymmetric approximation (ii) the turning duct, second stage ejectors and the piping downstream of the second stage ejectors were analyzed with a three-dimensional simulation utilizing a half-plane symmetry approximation. The solution i.e. primitive variables such as pressure, velocity components, temperature and turbulence quantities were passed from the first computational domain and specified as a supersonic boundary condition for the second simulation. (iii) The third domain comprised of the exit diffuser and the region in the vicinity of the facility (primary included to get the correct shock structure at the exit of the facility and entrainment characteristics). The first set of simulations comprising the engine, test cell and first stage ejectors was carried out both as a turbulent real gas calculation as well as a turbulent perfect gas calculation. A comparison for the two cases (Real Turbulent and Perfect gas turbulent) of the Ma Number distribution and temperature distributions are shown in Figures 1 and 2 respectively. The Mach Number distribution shows small yet distinct differences between the two cases such as locations of shocks/shock reflections and a slightly different impingement point on the wall of the diffuser from the expansion at the exit of the nozzle. Similarly the temperature distribution indicates different flow recirculation patterns in the test cell. Both cases capture all the essential flow phenomena such as the shock-boundary layer interaction, plume expansion, expansion of the first stage ejectors, mixing between the engine plume and the first stage ejector flow and pressurization due to the first stage ejectors. The final paper will discuss thermal loads on the walls of the diffuser and cooling mechanisms investigated.

Allgood, Daniel C.↗

Computational Analyses in Support of Sub-scale Diffuser Testing for the A-3 Facility: Steady Predictions - Part 1

Simulation technology can play an important role in rocket engine test facility design and development by assessing risks, providing analysis of dynamic pressure and thermal loads, identifying failure modes and predicting anomalous behavior of critical systems. Advanced numerical tools assume greater significance in supporting testing and design of high altitude testing facilities and plume induced testing environments of high thrust engines because of the greater inter-dependence and synergy in the functioning of the different sub-systems. This is especially true for facilities such as the proposed A-3 facility at NASA SSC because of a challenging operating envelope linked to variable throttle conditions at relatively low chamber pressures. Facility designs in this case will require a complex network of diffuser ducts, steam ejector trains, fast operating valves, cooling water systems and flow diverters that need to be characterized for steady state performance. In this paper, we will demonstrate with the use of CFD analyses s advanced capability to evaluate supersonic diffuser and steam ejector performance in a sub-scale A-3 facility at NASA Stennis Space Center (SSC) where extensive testing was performed. Furthermore, the focus in this paper relates to modeling of critical sub-systems and components used in facilities such as the A-3 facility. The work here will address deficiencies in empirical models and current CFD analyses that are used for design of supersonic diffusers/turning vanes/ejectors as well as analyses for confined plumes and venting processes. The primary areas that will be addressed are: (1) supersonic diffuser performance including analyses of thermal loads (2) accurate shock capturing in the diffuser duct; (3) effect of turning duct on the performance of the facility (4) prediction of mass flow rates and performance classification for steam ejectors (5) comparisons with test data from sub-scale diffuser testing and assessment of confidence levels in CFD based flowpath modeling of the facility. The analyses tools used here expand on the multi-element unstructured CFD which has been tailored and validated for impingement dynamics of dry plumes, complex valve/feed systems, and high pressure propellant delivery systems used in engine and component test stands at NASA SSC. The analyses performed in the evaluation of the sub-scale diffuser facility explored several important factors that influence modeling and understanding of facility operation such as (a) importance of modeling the facility with Real Gas approximation, (b) approximating the cluster of steam ejector nozzles as a single annular nozzle, (c) existence of mixed subsonic/supersonic flow downstream of the turning duct, and (d) inadequacy of two-equation turbulence models in predicting the correct pressurization in the turning duct and expansion of the second stage steam ejectors. The procedure used for modeling the facility was as follows: (i) The engine, test cell and first stage ejectors were simulated with an axisymmetric approximation (ii) the turning duct, second stage ejectors and the piping downstream of the second stage ejectors were analyzed with a three-dimensional simulation utilizing a half-plane symmetry approximation. The solution i.e. primitive variables such as pressure, velocity components, temperature and turbulence quantities were passed from the first computational domain and specified as a supersonic boundary condition for the second simulation. (iii) The third domain comprised of the exit diffuser and the region in the vicinity of the facility (primary included to get the correct shock structure at the exit of the facility and entrainment characteristics). The first set of simulations comprising the engine, test cell and first stage ejectors was carried out both as a turbulent real gas calculation as well as a turbulent perfect gas calculation. A comparison for the two cases (Real Turbulent and Perfect gas turbulent) of the Ma Number distribution and temperature distributions are shown in Figures 1 and 2 respectively.

Allgood, Daniel C.↗

Thermal Propulsion Capture System Heat Exchanger Design

One of the biggest challenges of manned spaceflight beyond low earth orbit and the moon is harmful radiation that astronauts would be exposed to on their long journey to Mars and further destinations. Using nuclear energy has the potential to be a more effective means of propulsion compared to traditional chemical engines (higher specific impulse). An upper stage nuclear engine would allow astronauts to reach their destination faster and more fuel efficiently. Testing these engines poses engineering challenges due to the need to totally capture the engine exhaust. The Thermal Propulsion Capture System is a concept for cost effectively and safely testing Nuclear Thermal Engines. Nominally, hydrogen exhausted from the engine is not radioactive, but is treated as such in case of fuel element failure. The Thermal Propulsion Capture System involves injecting liquid oxygen to convert the hydrogen exhaust into steam. The steam is then cooled and condensed into liquid water to allow for storage. The Thermal Propulsion Capture System concept for ground testing of a nuclear powered engine involves capturing the engine exhaust to be cooled and condensed before being stored. The hydrogen exhaust is injected with liquid oxygen and burned to form steam. That steam must be cooled to saturation temperatures before being condensed into liquid water. A crossflow heat exchanger using water as a working fluid will be designed to accomplish this goal. Design a cross flow heat exchanger for the Thermal Propulsion Capture System testing which: Eliminates the need for water injection cooling, Cools steam from 5800 F to saturation temperature, and Is efficient and minimizes water requirement.

Richard, Evan M.↗

Process of producing ethylene

A process of producing ethylene involving steam cracking ethane to produce a steam cracker product stream containing ethylene; cooling and drying the steam cracker product stream; contacting the cooled and dried steam cracker product stream with a MOF sorbent capable of adsorbing ethylene from the product stream, and desorbing the ethylene from the MOF sorbent using an ethylene sweep gas. The process replaces complex and energy intensive fractionation steps of the prior art with a selective adsorption step for separating ethylene from the steam cracker product stream. An energy efficient ethylene sorbent regeneration method and related apparatus systems are also disclosed.

Weissman, Jeffrey G.↗

Heat recovery from an electrochemical hydrogen separation system

An EHS system includes a EHS cell having an anode, a cathode, and a cooling plate disposed proximate at least one of the anode or the cathode, the cooling plate configured to receive water and configured to output steam or a mixture of water and steam. The system further includes a liquid-vapor separator (LVS) configured to receive the steam or the mixture of water and steam from the cooling plate and to separate water and steam. The LVS is configured to output water to the cooling plate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance and Economic Evaluation of sCO2 Bottoming Cycles for Natural Gas Combined Cycle Plants with Capture

Natural gas combined cycles (NGCCs) with carbon capture are expected to play a significant role in decarbonization of the power generation sector. NGCC plants generally use triple pressure reheat steam Rankine power cycles for the bottoming cycle. Some studies in the literature have investigated the application of recompression and cascade style supercritical CO2 (sCO2) cycles for NGCC bottoming cycle applications but these studies have focused on power plants without carbon capture. However, NGCC plants fitted with post-combustion solvent-based CO2 capture systems will require a significant amount of steam for solvent regeneration and this can have a major impact on the optimal sCO2 bottoming cycle design. This study investigates the performance and economic potential of sCO2 bottoming cycles for H-class gas turbine based NGCC plants with a post-combustion capture system. A portion of the gas turbine exhaust heat is used for generation of steam required for solvent-based capture system while the rest of the waste heat is utilized in an sCO2 bottoming cycle for power generation. Overall, the performance and LCOE of investigated sCO2 bottoming cycles is similar to that of a state-of-the-art triple pressure reheat steam Rankine cycle. As the gas turbine exhaust temperature increases (beyond 630oC), sCO2 bottoming cycles begin to show greater performance and economic benefits compared to a steam Rankine cycle.

Pidaparti, Sandeep↗

Techno-Economic Analysis of Sorbent-Based Direct Air Capture Informed by EPC Input and Recent Technological Advancements

Direct air capture (DAC) technology has been developing at an accelerated rate. Independent, comprehensive, and transparent techno-economic analyses (TEAs) of DAC technologies are required to inform future development. NETL is publishing an update to the 2022 sorbent-based DAC case study report. This manuscript highlights select TEA results that will be presented in the upcoming NETL report. The analysis considers three sorbent-based DAC system configurations (direct steam temperature swing, indirect steam temperature swing, and direct steam temperature/vacuum swing) and two scenarios for providing the required electricity and steam (stand-alone system with a combined heat and power plant generating the required steam and electricity, and a purchased power case utilizing an electric boiler). Detailed sensitivity analyses are included and highlight the impact of external market factors, sorbent performance, and economies of scale. The potential for cost reductions by opting for temperature vacuum swing adsorption is highlighted. More detailed background and TEA results will be presented in the upcoming NETL report titled “Direct Air Capture Case Studies: Sorbent System (Revision 1)”.

carbon dioxide removal↗

Enhancing biomass flowability for entrained flow Gasification: The role of densification and torrefaction

Gasification presents a key strategy in addressing future energy demands while minimizing environmental impact. This has been recognized as a promising method to convert biomass to higher value products such as biofuels or hydrogen. Among gasification technologies, high-temperature and high-pressure reactors, particularly the R-GAS® system, emerge as an advanced option boasting superior conversion efficiency. However, akin to conventional high-temperature and high-pressure gasifiers, R-GAS® necessitates small particle sizes for optimal carbon conversion, a requirement yet to be fully explored for biomass. Hence, this study investigated the effectiveness of combined mechanical and thermal preprocessing techniques in modifying the physicochemical properties of biomass to suit gasification systems. Mechanical techniques including densification and pulverization, alongside thermal techniques such as torrefaction and steam explosion, were examined. The results demonstrate that torrefaction fosters producing of uniform granular material, enhancing flowability and reducing energy requirements for pulverization compared to steam explosion. Notably, torrefied corn stover exhibited lower internal friction angles and effective cohesion (40.09 ± 0.22° and 0.56 ± 0.01 kPa, respectively) compared to steam exploded corn stover (41.87 ± 0.65° and 0.83 ± 0.06 kPa, respectively), indicative of improved flowability. Additionally, pulverization of torrefied corn stover required approximately 16 % less energy than steam exploded corn stover and 91 % less energy than raw corn stover. Furthermore, the torrefaction-induced alterations in particle size, shape, and packing densities emphasize its potential to optimize flow and handling processes for gasification. These findings underline that densification followed by torrefaction effectively addresses biomass variability, leading to more efficient and sustainable energy conversion.

09 - BIOMASS FUELS↗

Process Heat for Chemical Industry

Process heating with nuclear energy can reduce greenhouse gas emissions by reducing combustion of fossil fuels in fired heaters as steam boilers. Light water reactors can replace the majority of steam duties used by industry; however, high temperature processes such as steam methane reforming require advanced high temperature reactors. Here, guidance on matching the scale of nuclear reactors with specific industries is provided. Principles of heat transport, temperature boosting, and substitution for hot combustion gases are also discussed in this section.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A New Class of Proton Conductors with Dramatically Enhanced Stability and High Conductivity for Reversible Solid Oxide Cells

Reversible solid oxide cells based on proton conductors (P-ReSOCs) have potential to be the most efficient and low-cost option for large-scale energy storage and power generation, holding promise as an enabler for the implementation of intermittent renewable energy technologies and the widespread utilization of hydrogen. Here, the rational design of a new class of hexavalent Mo/W-doped proton-conducting electrolytes with excellent durability while maintaining high conductivity is reported. Specifically, BaMo(W) 0.03 Ce 0.71 Yb 0.26 O 3-δ exhibits dramatically enhanced chemical stability against high concentrations of steam and carbon dioxide than the state-of-the-art electrolyte materials while retaining similar ionic conductivity. In addition, P-ReSOCs based on BaW 0.03 Ce 0.71 Yb 0.26 O 3-δ demonstrate high peak power densities of 1.54, 1.03, 0.72, and 0.48 W cm –2 at 650, 600, 550, and 500 °C, respectively, in the fuel cell mode. During steam electrolysis, a high current density of 2.28 A cm –2 is achieved at a cell voltage of 1.3 V at 600 °C, and the electrolysis cell can operate stably with no noticeable degradation when exposed to high humidity of 30% H 2 O at –0.5 A cm –2 and 600 °C for over 300 h. Altogether, this work demonstrates the promise of donor doping for obtaining proton conductors with both high conductivity and chemical stability for P-ReSOCs.

25 ENERGY STORAGE↗

Build Orientation Dependent Microstructure in Polymer Laser Sintering: Relationship to Part Performance and Evolution with Aging

Laser sintering (LS) is widely used to produce functional polymeric parts; however, the resulting parts are often limited by their porous structure, and performance of the part may be strongly anisotropic. Relating the structural features of parts to build process conditions or powder feedstock has been explored previously. In contrast, little is known regarding how the unique internal structures of LS parts evolve and relate to their performance later in their life cycle, for example, after use in a real-world operating environment. In this study, a tightly controlled LS build process and measurement campaign by standard X-ray computed tomography (XCT), supported by high-resolution synchrotron XCT, was used to benchmark the internal microstructure (e.g. porosity) as a function of four different build orientations in printed polyamide-12 (PA-12) parts. The initial performance of the parts after printing was characterized by tensile testing and dynamic mechanical analysis (DMA). Arrays of PA-12 parts in different build orientations were exposed to steam (under pressure) and air across multiple temperature and time points for the purposes of accelerated aging through oxidative and hydrolytic breakdown. Exposing parts to steam dramatically altered the internal microstructure and functional properties such as the glass transition temperature, tensile properties, and damping behavior. Notably, post-aging XCT revealed large microstructural changes after only 40 h of steam treatment relative to the as-printed specimens. Furthermore, pore reorganization and changes in crystallinity occurred regardless of whether the steam temperature was aggressive enough to induce a significant loss in mechanical properties. The build orientation dependence on the aging rate was minimal with the relative trend in performance persisting across most metrics among the different orientations even after aging.

36 MATERIALS SCIENCE↗

Electrochemically Engineered, Highly Energy-Efficient Conversion of Ethane to Ethylene and Hydrogen below 550 °C in a Protonic Ceramic Electrochemical Cell

Ethylene is one of the largest building blocks in the petrochemical industry, mainly produced by steam cracking of ethane derived from naphtha or shale gas at high temperatures (>800 °C). Despite its technical maturity and economic competitiveness, the thermal steam cracking of ethane is highly energy-intensive. In this work, an electrochemically engineered direct conversion process of ethane to produce hydrogen and ethylene using a planar protonic ceramic membrane reactor with a bi-functional three-dimensional catalytic electrode is reported, with a single-pass ethane conversion of 40% and ethylene yield of 26.7% at 550 °C. Compared with the industrial ethane steam cracking, this method saves process energy input by 45.1% and improves process energy efficiency by 50.6%, based on comprehensive process simulation using Aspen Plus software. Further, steam electrolysis treatment under the solid oxide electrolysis cell mode can regenerate the system’s catalytic performance and significantly alleviate catalytic degradation by 74%, demonstrating high techno-economic viability.

bi-functional electrode↗

Proton surface exchange kinetics of perovskite triple conducting thin films for protonic ceramic electrolysis cells: BaPr 0.9 Y 0.1 O 3–δ (BPY) vs. Ba 1–x Co 0.4 Fe 0.4 Zr 0.1 Y 0.1 O 3–δ (BCFZY)

Protonic ceramic electrolysis cells (PCECs) are an attractive green H 2 production technology, given their intermediate-temperature operating range and ability to produce dry H 2 . However, PCECs will benefit from development of more efficient and durable “triple conducting” anodes where steam is split, H incorporated, and oxygen evolved. In this work, we evaluated the kinetics of the steam-splitting/H incorporation reaction on BaPr 0.9 Y 0.1 O 3–δ (BPY) in comparison to the benchmark Ba 1–x Co 0.4 Fe 0.4 Z r0.1 Y 0.1 O 3–δ (BCFZY) composition, replacing most of the transition metal elements (Co, Fe, Zr) with the lanthanide Pr. We prepared geometrically well-defined perovskite BPY and BCFZY thin films by pulsed laser deposition and performed simultaneous optical transmission relaxation and electrical conductivity relaxation measurements at 400–500 °C in 0.21 atm O 2 during switching of the steam partial pressure to isolate and compare their proton surface exchange coefficients (k). The k values of BPY were comparable to those of BCFZY and more stable over time. According to angle-resolved XPS and STEM-EDS mapping of FIB cross-sections, the surface of BPY exhibited Ba enrichment, Pr deficiency, and Si contamination. In contrast, BCFZY exhibited Ba deficiency throughout, no obvious surface segregation, and less Si contamination. The Ba segregation on the BPY film appears to have promoted steam splitting/H incorporation kinetics even though the more basic surface reacted with the acidic environmental SiO x H y . Faster kinetics observed on stoichiometric BCFZY vs. Ba-deficient BCFZY confirmed the benefit of a high A-site Ba concentration. This result contrasts with most work on perovskites applied in solid oxide electrolysis cell anodes, in which A-site segregation is considered deleterious for surface reaction kinetics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Competitiveness Assessment of Decarbonizing Electricity and Process Heat Supply to a Campus with a Small Nuclear Reactor

This paper analyzes the competitiveness of siting a small nuclear reactor to support decarbonization of sites requiring tens of MW of electricity and/or process heat to support centralized heating and cooling system. This paper focuses on campuses as representative of sites with collections of buildings and research facilities with decarbonization needs represented by buildings heating, and electricity consumption by electrical loads which may include cooling via chilled water (e.g., for air conditioning and to cool down computer clusters). A nuclear reactor can be considered to decarbonize a site’s high-temperature steam generation used mostly for building heating needs, climate control, and hot water, by supplying process heat capabilities, while electricity decarbonization would be achieved mostly by the grid. However, a secondary application can be considered to maximize reactor utilization and avoid ramping down the reactor if the steam demand varies significantly throughout the year. Chilled water generation through steam-driven systems was identified as an attractive secondary option for the site analyzed, due to potential for plant design simplification, while electricity generation could be considered as well to reduce electricity purchases for a wider range of site applications. For a campus with peak 60MW thermal power demand, a small nuclear reactor with similar thermal power rating would almost eliminate CO2 emissions from steam generation and reduce electricity imports for chilled water production. A preliminary techno-economic feasibility study shows that a small nuclear reactor design that is optimized to support process heat can represent an economically feasible option when compared with other decarbonization alternatives.

Stauff, Nicolas E.↗

NH 4 OH Looping with Membrane CO 2 Absorber and Distributed Stripper for Enhanced Algae Growth

The University of Kentucky Center for Applied Energy (UK CAER) has devised a unique, integrated CO2 capture and utilization technology. CO2 from coal-fired power generation flue gas is first captured at half the operating cost of a typical aqueous CO2 capture system (CCS), distributed in an aqueous stream and then fixed by algae in bioreactors where the algae production is increased by 50% over that with a typical intermittent nutrient feeding system. Lower CCS operating cost is achieved by eliminating the flue gas pretreatment step for cooling and SO2 removal, eliminating steam extraction from the power generation steam cycle for solvent regeneration, and eliminating CO2 compression. Higher algae production is achieved by continuous, just-in-time nutrient feed to the bioreactors directly from a distributed solvent regenerator, which maintains the bioreactor pH for optimum growth. The process starts with a uniquely configured membrane absorber, where the flue gas is indirectly contacted with an ammonium hydroxide (NH4OH) solvent. Dissolved NH3 is attractive for both CO2 capture and as an algae nutrient. For CO2 capture it is inexpensive, has a low regeneration energy, is thermally- and oxidatively-stable and has a viscosity near that of water, which makes is easy to transport. Numerous studies have shown that the scrubbing capacity of NH3 is approximately 0.9-1.2 kg of CO2/kg of NH3, with a CO2 removal efficiency of ~99% and half the solvent regeneration energy than that of 30 wt% MEA[1, 2, 3]. NH3 is attractive as an algae nutrient due to its low cost. The rich NH4OH solvent is pumped to a set of distributed regenerators which are co-located with the algae bioreactors. Solvent pumping, transport and distribution reduces the balance of plant (BOP) cost compared to a typical aqueous CCS related to the flue gas duct and boost fan required to transport the flue gas. The energy required for the distributed solvent regeneration is supplied by solar-thermal panels eliminating the need for steam extraction from the power generation steam cycle. After solvent regeneration, the product stream contains both the CO2 captured from the flue gas and volatized NH3 from the solvent. This product stream is fed directly to the bioreactors, eliminating the need for compression of the CO2 stream. The relative amounts of CO2 and NH3 in the product stream are adjusted and controlled by a controlling the regeneration conditions (pressure and temperature). The continuous feed of the right ratio of nutrients overcomes the typical inhibition of algae growth resulting from frequent pH swings in the bioreactor due to unbalanced (intermittent) feeding systems for CO2 and N. Also, because the regenerators will operate at pressure and be located in close proximity to the bioreactors, there is no worry about pressure drop when sparging the gas into the algae. Sparging produces small bubbles which is beneficial for mass transfer efficiency. One known challenge when using an NH4OH solvent is high NH3 emission. Hydrophobic membranes are used for CO2 capture using an aqueous NH3 solution[4, 5] without the direct contact between flue gas and aqueous solution. Additionally, UK CAER CO2 capture and utilization process manages NH3 slip in three extra measures. First, NH3 slip is minimized by working with minimal species partial pressure, which is proportional to the concentration in the liquid. Hence, lowering the capture solvent concentration will lower the NH3 partial pressure. Second, UK CAER’s previous work has demonstrated that the addition of Zn2+ into NH3 solutions to chelate the NH3 can reduce NH3 volatility. Third, the configuration of the membrane CO2 absorber utilizes condensed water from the flue gas to continually wash the gas-side of the membrane to reduce fouling and recapture NH3 slip. Additional details about the UK CAER unique, integrated CO2 capture and utilization technology will be presented along with technology development plans. Diao, N., Q. Li, and Z. Fang. 2004. Heat transfer in ground heat exchangers with groundwater advection. International Journal of Thermal Sciences. 43: 1203-1211, He, Q., M. Chen, L. Meng, K. Liu, and W. Pan. 2004. Study on Carbon Dioxide Removal from Flue Gas by Absorption of Aqueous Ammonia. Western Kentucky University. Yeh, A.C., and H. Bai. 1999. Comparison of ammonia and monoethanolamine solvents to reduce CO2 greenhouse gas emissions. The Science of the Total Environment. 228: 121-133, Villeneuve, K., D. Roizard, J.C. Remigy, M. Iacono, and S. Rode. 2018. CO2 capture by aqueous ammonia with hollow fiber membrane contactors: Gas phase reactions and performance stability. Separation and Purification Technology, 199: 189-197, Toro Molina, C., and C. Bouallou. 2016. Carbon dioxide absorption by ammonia intensified with membrane contactors. Clean Techn Environ Policy 18, 2133–2146 (2016)

20 FOSSIL-FUELED POWER PLANTS↗

Wyandotte Integrated Renewable Energy Strategy (WIRES 2) (Final Technical Report)

Wyandotte Municipal Services (WMS), a Michigan Municipal Utility offering electric generation, transmission & distribution, water filtration & distribution and Broadband/Video sought to deploy a set of renewable energy projects for their Electric Utility that contributed to reducing the City’s environmental and energy impact, provided examples that would encourage businesses and citizens to adopt cleaner energy practices and help WMS meet the required renewable energy standards of the State of Michigan (10% in 2015, 15% in 2021). WMS generates and delivers roughly 280,000 megawatt hours (MWh) of electricity annually to more than 10,000 homes and 1,000 businesses within the City of Wyandotte. The Wyandotte Integrated Renewable Energy Strategy – WIRES 2 resulted in deployment of a set of community-scale micro-wind turbines, evaluation and installation of energy-efficient and low-maintenance light-emitting diode (LED) street lights and park lights in highly visible locations in the City and expansion of the geothermal heating and cooling district that already included residential geothermal systems, to include larger scale business/institutional systems at the Utility’s largest electric customer and at the City Library. Finally, WMS identified the need for job training in energy efficiency and renewable energy technologies to further develop a local skilled workforce in these areas. Partially funded by the grant, the wind turbine project provides a benchmark for WMS, local businesses and residents in the evaluation of utility-scale wind v. micro-wind in an urban environment as a renewable energy strategy. Also partially funded by the grant, the LED project benefited the City of Wyandotte by reducing load on the electric system for the public utility but also reduced City costs for streetlighting, parking lot lighting and park lighting without a compromise in security. The project also resulted in a visual success that has led to additional approvals for non-Grant related LED lighting installations resulting in further reduction in the electric load in the City. Commercial Geothermal installations resulted in the Utility being able to eliminate steam customers who formerly utilized the byproduct of steam from WMS electric production. Due to the reduction in natural gas prices and the overall reduction in market purchased power, it was no longer feasible for WMS to operate its Power Plant as a base load plant and to only operate on a market dispatch philosophy when market prices dictated that WMS could produce electricity cheaper than the market purchase price. This has resulted in fewer operating days for the WMS Power Plant, resulting in less environmental impact. WMS has now completely exited the steam business and the ability to offer a geothermal option to two (2) former steam customers (BASF-Wyandotte and the Bacon Memorial Library) allowed for that. In addition, peak loads have been shaved for these two (2) large customers due to the consistent temperature offered by geothermal heating and cooling, reducing the swings associated with thermostat changes caused by outside temperature changes during extreme high and low temperatures. Finally, energy efficiency and renewable energy college-level classes at Wayne County Community College allowed a group of interested students to pursue studies in those technologies through grant provided tuition, books and course materials. This effort provided a foundation of potential future employees not only for WMS but other energy efficiency/renewable energy employers such as Franklin Energy, a partner with WMS in energy optimization efforts with Wyandotte businesses.

17 WIND ENERGY↗

Oxy-Combustion System Process Optimization

The overall objective of this work is to develop a new chemical absorbent-based, high pressure, CO 2 purification system to remove the residual oxygen that currently contaminates the recovered CO 2 , and to optimize the Pressurized Oxy-Combustion (POxC) process to minimize the Cost of Electricity (COE) generated in this advanced combustion process. TDA developed and validated the performance of the oxygen removal system for CO 2 purification. In collaboration with the Advanced Power & Energy Program (APEP) of University of California, Irvine (UCI), we optimized the POxC process, including thermal management, heat integration, and power cycle optimization using process design and modeling supported with Aspen Plus® process simulations. The techno-economic analysis results indicate that the pressurized oxycombustion coal power plant with Ion-transport membrane (ITM) air separation unit (ASU) (Case 2 – 30.55%) does not show an advantage over a cryogenic ASU (Case 1 – 31.24%) while TDA’s sorption-based ASU (Case 4 - 32.61%) shows a significant advantage over the cryogenic ASU (Case 1 – 331.24%). The specific plant costs show a wide range with a low of $2544/kW for Case 11C (TDA ASU, co-sequestering the SO x , and ultra-supercritical steam cycle) to a high of $2975/kW for Case 12A (cryogenic ASU and sCO 2 cycle). In general, the ITM ASU based cases have lower specific plant costs than the corresponding cryogenic ASU based cases while the TDA ASU based cases show the lowest specific plant costs. The main reason for lowering these costs is the higher overall plant thermal efficiency which decreases the plant cost on a $ per kW basis. Next comparing the cases with different power cycle working fluid conditions in terms of temperature and pressure while all utilizing steam, similar trends as the plant costs may be observed. However, with the supercritical CO 2 (sCO 2 ) cycle, the increase in thermal efficiency of the sCO 2 cycle was not able to offset its increase in plant cost making the plant costs higher than those of the corresponding steam cycle cases. The Cost of Electricity (COE) again shows similar trends as the specific plant costs. The COE for Case 11C at $110.1/MWh is also the lowest, but among all cases that do not co-sequester the SO x , Case 12C (TDA ASU and sCO 2 cycle) has the lowest COE at $\$$117.5/MWh while the highest is for Case 8A (cryogenic ASU and supercritical steam cycle) at $130.4/MWh.

20 FOSSIL-FUELED POWER PLANTS↗

Supercritical Carbon Dioxide Primary Power Large-Scale Pilot Plant

The United States electrical power generation fleet encompasses a wide range of technologies, ranging from traditional combustion-based power generation, to nuclear power, to renewable energy. While the distribution of these assets continues to shift due to economic and regulatory influences, coal combustion continues to be a key part of the US energy portfolio. Despite the relative maturity of coal combustion technology, improvements in overall fuel-to-power efficiency and generation flexibility are still possible and will improve both the economic and environmental factors of coal combustion. Echogen Power Systems proposes to lead a world-class team including the University of Missouri, Electric Power Research Institute and Louis Perry Associates in the design, construction and operation of a 10MWe coal-fired supercritical carbon dioxide (sCO 2 ) large-scale pilot. This transformational technology uses sCO 2 as a working fluid instead of water to achieve high thermodynamic efficiencies that can significantly exceed advanced steam-Rankine cycles. Further, the compact nature of sCO 2 turbomachinery offers capital cost and footprint advantages, and the low maintenance of a water-free power cycle can significantly reduce operation and maintenance (O&M) costs over conventional steam-Rankine systems. Recent integration studies of sCO 2 with coal combustion power plants highlight the significant improvements in plant efficiency that sCO 2 can offer relative to even advanced steam Rankine cycles. At commercial scales, coal-sCO 2 plant net efficiency is predicted to be 39-44.0% (HHV), or 10-20% higher output than conventional steam-Rankine systems, which will significantly improve the competitiveness of coal-fired generation. This proposal builds upon projects previously funded by the Department of Energy, including DE-FE0025959 (High-Efficiency Thermal Integration of Closed Supercritical CO 2 Brayton Power Cycles with Oxy-Fired Heaters) and DE-NE0008470 (Conceptual Design for sCO 2 Power Cycle Test Facility). An appropriately-scaled and properly designed and operated pilot project is essential to overcome the natural risk-aversion of the power generation industry and project financing community. The 10 MWe coal-fired sCO 2 pilot power plant proposed herein will reduce the technical and economic risk of this transformational technology, enabling commercial deployment at the conclusion of the project. For the second phase of this project, Echogen lead a team that completed and refined the pilot system conceptual system and key component designs resulting in the completion of a front-end-engineering-design (FEED) study, completed the NEPA review process, completed the permitting process for construction and operation, refined the techno-economic analysis of the proposed system at commercial scale and received commitments for Phase III cost share. The end result of the program will be to demonstrate the technical and economic superiority of the sCO 2 power cycle for coal-fired operation. Major risk elements will have been retired with sufficient operation at high power to enable the power generation industry to move forward with the first commercial deployment of this transformational system.

01 COAL, LIGNITE, AND PEAT↗