Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample Handling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Isolation Standard Measures: A Set of Validated and Feasible Measurements Ensuring Comparability Across Isolation and Confinement Studies

Isolation and confinement studies have been essential to the preparation of crewed long-duration space missions, acting as analogues that facilitate the study of psychological and physiological responses to isolation and confinement. They also serve as opportunities for the development, testing, and validation of countermeasures and coping methods to handle the challenges that arise in such scenarios. Due to the small sample sizes in combination with high inter-individual variability, single isolation campaigns are not always sufficient for obtaining statistically significant scientific findings. To address this issue and improve comparability between different studies, the need for standardized measures to be collected in all future isolation and confinement studies was identified. Additionally, these measures should also be shown to be generally valid, reliable, feasible and acceptable in analogue and spaceflight environments. Standard measures in isolation and confinement studies allow for more direct comparisons of results and synthesis of data across isolation and confinement studies as well as provide an important step toward standard measures in spaceflight. An international expert group with representatives from different space agencies worldwide was brought together to define a core set of standard measures for isolation and confinement studies. This paper provides an overview of the expert group’s recommendations for international standard measures for future isolation and confinement studies, along with subsequent updates coordinated by the International Countermeasures Working Group (ICMWG), which was established as a sub-Working Group under the International Space Life Sciences Working Group (ISLSWG). Additional experts were consulted by the ICMWG partner agencies as required. The collection of the described set of isolation standard measures will provide data on the following parameters: sleep, mood, psychological state, psychophysiology, cognitive performance, stress and the immune system, general health and well-being, team measures, nutritional measures, and environmental conditions. For each measure, recommendations were made about duration and frequency of administration, along with specific implementation recommendations in relation to the duration of the isolation study. The set of isolation standard measures will be reassessed every two years at a minimum to ensure they are up to date and reflect the current state-of-the-art.

Isolation↗

The use of Whatman-41 filters for high volume air sampling

The feasibility of using W41 filter media on a routine TSP high-volume monitoring network was determined by comparison with glass fiber (GF) filtering. Results indicate that suspended particulate samples from GF filters averaged slightly, but not significantly, higher than those from Whatman-41 filters. Some extra handling procedures were required to avoid errors due to the hygroscopic nature of W41 filters; these added procedures are not overly burdensome, however, and they allow the performance of analytical work, thus extending the capabilities of high-volume sampling. It was demonstrated that W41 filters are practical for air quality monitoring and elemental analysis in environments similar to Cleveland's.

Neustadter, H. E.↗

The Art of Automation: Translating Electron Microscopy Workflows Into Automated Processes

Acquiring data using a scanning transmission electron microscope (STEM) is a complex, multi-step process. The intricacy of the process depends on the type of sample, composition of the material, desired results of the experiment, resolution requirement and other experimental factors. Each experiment presents unique complications, such as sample drift and contamination, that the microscopist must consider when acquiring data. All these challenges are handled fluidly and expertly by experienced microscopists, but to reach new levels of innovation in material development, including greater reproducibility, throughput, and precision, the automation of these workflows is essential. The initial phase of this work involved translating intuition-based workflows into discrete, programmable steps. Some common key stages in STEM workflows are the initial tuning, scanning the sample for areas of interest, and then acquiring the data. Each stage can be broken further into specific parameter adjustments, such as aberration correction and dwell time optimization, depending on the experiment. When deconstructing various experiments each step was assessed for automation feasibility based on the amount of real time operator decisions. There are steps that lend themselves to automation more readily than others, such as course focusing and sample screening, but there is potential for full automation of all stages with time. As an initial step, an automated montage routine was developed, allowing for the efficient acquisition of large portions of the sample without requiring continuous intervention from the operator. The automation of this small process of the procedure demonstrates the value of this capability. A major challenge in automation arises from discrepancies between commanded, reported and actual stage movements. Using systematic tests, stage movement was quantified. This error can be corrected algorithmically for more accurate workflows in the future. Expanding automation capabilities would result in larger, more efficient data acquisition which allows for more robust statistical analysis. Additionally, this work lays the groundwork for a closed loop system where machine learning algorithms would intake automatically acquired data and make real time decisions. By progressively automating this instrument, this work establishes the foundation for fully automated experimentation in transmission electron microscopy.

97 MATHEMATICS AND COMPUTING↗

New Hayabusa2 and OSIRIS REx Curation Facilities at Nasa Johnson Space Center

Asteroids are made up of rocky material that is left over from the formation of our solar system [1]. This material holds the key to unlocking information about the history of the planets and our sun. Hayabusa2 and OSIRIS-REx are two sample return missions that have collected rocky material from carbonaceous asteroids which are rich in water, carbon, and organic compounds [1]. Hayabusa2 is a spacecraft that collected samples from asteroid Ryugu launched by the Japan Aerospace Exploration Agency (JAXA). Samples were returned to Earth in December 2020 and 10 percent of the collected material is currently housed in a state-of-the-art laboratory at NASA Johnson Space Center (JSC) dedicated to Ryugu material [1]. OSIRIS-REx is a spacecraft launched by NASA that collected samples from asteroid Bennu. The samples are on their journey to Earth and will arrive in September 2023. They will be stored in a separate cleanroom dedicated to Bennu material. From these two missions, scientists will examine dust particles and rocky material to research clues on how the early solar system formed and how life began [2]. Because these samples are so precious and rare, it is important to keep them free from Earth contamination. In September of 2020, a massive construction project began to provide curation facilities to meet the needs of two incoming asteroid collections, Hayabusa2 and OSIRIS-REx. Despite numerous setbacks caused by the coronavirus pandemic, these facilities have been completed in the fall of 2021. Some of these setbacks included strict PPE requirements, keeping safe working distances as well as access to the facilities as NASA was operating under a Stage 3 condition in response to the pandemic. These facilities will provide curation laboratories to safely house the precious asteroid samples as well as facilities to manipulate samples, do sample preparation and process samples into and out of the labs for future studies by the scientific community. The lab suite consists of several different rooms including an initial anteroom (ISO 7), a staging area (ISO 7), two gowning areas (one for OSIRIS-REx and one for Hayabusa2; both ISO 6)), the Haybusa2 Curation Laboratory (ISO 5), the OSIRIS-REx Curation Laboratory (ISO 5), an ultramicrotomy laboratory (ISO 7) and a thin section laboratory (not a cleanroom). To maintain cleanliness levels necessary for these lab spaces quarterly to monthly Balazs organic and inorganic sampling has been conducted on a regular basis before, during and after the construction project to monitor the cleanliness levels in the new labs that will house the asteroid samples. These new facilities feature a Ruuvi (Grafana) monitoring system that measures temperature, humidity, and pressure of the lab suite. This is a small puck shaped sensor that sends signals to the Grafana cloud where the data can be plotted and set up on dashboards within the lab suite. These sensors are easy to set up and install and they run off a cell battery that is good for 3-5 years before needing replacement. This system can deliver text messages and emails to the appropriate personnel when values fall outside of set limits. In addition to the monitoring system, this new lab suite features viewing windows from several different locations and sliding motion censored doors. We have obtained some state-of-the-art equipment to outfit the lab spaces (desiccators, microscopes, ultramicrotome) and are in the process of outfitting the suite with additional items such as: nitrogen gloveboxes, additional desiccators, micromanipulators, etc. The Hayabusa2 samples provided to NASA by JAXA included 23 millimeter sized grains and 4 containers with finer material. OSIRIS-REx is expected to return as much as 400 grams of asteroid Bennu. Samples will be stored in a nitrogen glove box and separated into nitrogen sealed transfer containers. Small Bennu and Ryugu particles will be handled and prepared (e.g., ultra-thin sections for scanning electron microscopy (SEM) or transmission electron microscopy (TEM)) using an Axis Pro micromanipulator and Leica EM UC7 ultramicrotome. Analyzing samples at the atomic scale will provide greater insight to the origins of the solar system and life formation on Earth. All the curation preparation for these sample collections is essential to ongoing research and efforts to understand our solar system, both nowand for future generations.

Curation↗

Programs for computing abscissas and weights for classical and nonclassical Gaussian quadrature formulas

Computer programs for computing Gaussian quadrature abscissas and weights are described. For the classical case the programs use Laguerre iteration to compute abscissas as zeros of orthogonal polynomials. The polynomials are evaluated from known recursion coefficients. The nonclassical case is handled similarly except that the recursion coefficients are computed by numerical integration. A sample problem, with input and output, is presented to illustrate the use of the programs. It computes the quadrature abscissas and weights associated with the weight function over the interval (0,1) for quadrature orders from 16 to 96 in increments of 8.

Desmarais, R. N.↗

Rayleigh Scattering Diagnostic Used to Measure Velocity and Density Fluctuation Spectra

A new, molecular Rayleigh-scattering-based flow diagnostic developed at the NASA Glenn Research Center has been used for the first time to measure the power spectrum of both gas density and radial velocity components in the plumes of high-speed jets. The objective of the work is to develop an unseeded, nonintrusive dynamic measurement technique for studying turbulent flows in NASA test facilities. This technique provides aerothermodynamic data not previously obtainable. It is particularly important for supersonic flows, where hot wire and pitot probes are difficult to use and disturb the flow under study. The effort is part of the nonintrusive instrumentation development program supporting propulsion research at the NASA Glenn Research Center. In particular, this work is measuring fluctuations in flow velocity, density, and temperature for jet noise studies. These data are valuable to researchers studying the correlation of flow fluctuations with far-field noise. One of the main objectives in jet noise research is to identify noise sources in the jet and to determine their contribution to noise generation. The technique is based on analyzing light scattered from molecules within the jet using a Fabry-Perot interferometer operating in a static imaging mode. The PC-based data acquisition system can simultaneously sample velocity and density data at rates to about 100 kHz and can handle up to 10 million data records. We used this system to interrogate three different jet nozzle designs in a Glenn free-jet facility. Each nozzle had a 25.4-mm exit diameter. One was convergent, used for subsonic flow measurements and to produce a screeching underexpanded jet with a fully expanded Mach number of 1.42. The other nozzles (Mach 1.4 and 1.8) were convergent-divergent types. The radial component of velocity and gas density were simultaneously measured in this work.

Seasholtz, Richard G.↗

Stereomicroscope Inspection of Polished Aluminum Collector 50684.0

The Genesis polished aluminum "kidney" collector was damaged during the hard landing of the capsule on September 8, 2004 in the Utah desert. The kidney was introduced into the Genesis (ISO class 4) cleanroom laboratory on November 4, 2004 and stored under nitrogen cover gas. The collector is currently fastened to a highly polished stainless steel plate for secure handling. Curatorial work at JSC has made successful subdivision and subsequent allocation of samples from the kidney.

Rodriquez, M. C.↗

Sample Materials Considerations for Curating and Processing Pristine MSR Samples

The perseverance rover is collecting and caching samples of Mars as part of the Mars 2020 mission, which represents the first leg of a multi-mission Mars Sample Return Campaign. The MSR Campaign is an international partnership that will result in delivery of the first martian samples to Earth that were not delivered through meteoritic infall. All meteorites, regardless of how they were handled from recovery to curation, have experienced uncontrolled entry and exposure to the terrestrial environment. Whilst meteorite deliveries are serendipitous, they are also unplanned events that require reactionary responses for recovery and curation. However, with the direct return of pristine astromaterials from another body, we are afforded the ability to design a facility in advance of sample delivery to keep those samples in a pristine (i.e., as returned) state for an indefinite period of time. Given that the curation and processing infrastructure needs to be made out of something, it is important to choose materials for the pristine curation environment that will optimize between the need to effectively process samples and the need to minimize contamination of the samples. The Johnson Space Center (JSC) has an optimized list of materials that have been used in previous sample return missions that includes 304/316 Stainless Steel, Teflon, and T6061 Aluminum (1). This set of materials are compatible with inorganic, organic, and biological cleanliness requirements and protocols. Furthermore, only these materials are permitted to come in contact with pristine samples. We note that JSC uses Neoprene and Hypalon for the gloves on their gloveboxes, but the glove material never comes in direct contact with the samples, only the approved materials. The MSR sample tubes will be made of Ti, so Ti may be an acceptable material for making tools, but the minor and trace element abundances of 304 and 316 stainless steel are well known and do not inhibit scientific investigations of metals, including HSE (2). More work is needed to determine whether the same is true for Ti alloys. In addition to defining the materials in the pristine environment, one must also choose whether the pristine environment will be under vacuum or under a specific atmospheric composition and pressure. Although JAXA has successfully implemented pristine curation vacuum chambers for their Hayabusa and Hayabusa2 samples (3), a vacuum environment is not appropriate for martian samples because it may drive deliquescence of mineral phases in the samples that are sensitive to pressure and relative humidity (4). Consequently, the pristine environment for the martian samples should be under an inert gas. It will be crucial to minimize the number of gases that come into direct contact with samples and these gases will need to be high purity and consistent throughout the pristine isolators. Samples at JSC are stored under high purity gaseous nitrogen (1). Dry N2 gas has not been a problem for N isotope studies for high-T release phases, but an additional inert atmosphere like Ar may be needed for samples where there is a particular concern about low-T release of N from bulk sample analysis. References: (1) McCubbin FM, et al. (2019) Space Science Reviews, 215, 1-81. (2) Day JMD, et al. (2018) Meteorit. Planet. Sci. 53:1283-1291. (3) Yada, T., et al., (2014). Meteorit. Planet. Sci. 49, 135-153. (4) Tosca NJ, et al. (2021). Astrobiology, in press, doi:10.1089/ast.2021.0115.

F M McCubbin↗

Regolith Evolved Gas Analyzer

The Regolith Evolved Gas Analyzer (REGA) is a high-temperature furnace and mass spectrometer instrument for determining the mineralogical composition and reactivity of soil samples. REGA provides key mineralogical and reactivity data that is needed to understand the soil chemistry of an asteroid, which then aids in determining in-situ which materials should be selected for return to earth. REGA is capable of conducting a number of direct soil measurements that are unique to this instrument. These experimental measurements include: (1) Mass spectrum analysis of evolved gases from soil samples as they are heated from ambient temperature to 900 C; and (2) Identification of liberated chemicals, e.g., water, oxygen, sulfur, chlorine, and fluorine. REGA would be placed on the surface of a near earth asteroid. It is an autonomous instrument that is controlled from earth but does the analysis of regolith materials automatically. The REGA instrument consists of four primary components: (1) a flight-proven mass spectrometer, (2) a high-temperature furnace, (3) a soil handling system, and (4) a microcontroller. An external arm containing a scoop or drill gathers regolith samples. A sample is placed in the inlet orifice where the finest-grained particles are sifted into a metering volume and subsequently moved into a crucible. A movable arm then places the crucible in the furnace. The furnace is closed, thereby sealing the inner volume to collect the evolved gases for analysis. Owing to the very low g forces on an asteroid compared to Mars or the moon, the sample must be moved from inlet to crucible by mechanical means rather than by gravity. As the soil sample is heated through a programmed pattern, the gases evolved at each temperature are passed through a transfer tube to the mass spectrometer for analysis and identification. Return data from the instrument will lead to new insights and discoveries including: (1) Identification of the molecular masses of all of the gases liberated from heated soil samples; (2) Identification of the asteroid soil mineralogy to aid in the selection process for returned samples; (3) Existence of oxygen in the asteroid soil and the potential for in-situ resource utilization (ISRU); and (4) Existence of water and other volatiles in the asteroid soil. Additional information is contained in the original extended abstract.

Hoffman, John H.↗

Paper or Plastic? Multiscale Material Handling Properties of Two Model Municipal Solid Waste Streams

Purpose: Municipal Solid Waste (MSW) is a potentially valuable sustainable feedstock for fuel and chemical production due to its carbon-rich content and low cost. This study aims to assess the material handling properties of paperand plastic-rich MSW feedstocks to mitigate equipment failure and processing downtime. Methods: The material handling properties of crumbled MSW feedstocks were measured using apowder rheometer with mass flow hopper calculations to assess handling performance. Inverse gas chromatography was use to measure the surface energy differences between feedstocks. Electron microscopy and Raman spectroscopy was used to evaluate microscale features that may contribute to material handling differences. Results: Plastic and paper rich feedstocks crumbled to a nominal 2 mm particle size were observed to have similar flow and handling characteristics with reasonable hopper outlets. 2 mm plastic rich crumbles, with their higher bulk density, exhibited superior flow performance. By contrast, 4 mm material required significantly larger hopper outlets, indicating poor flowability. Paper rich and 4 mm plastic rich samples displayed broad particle size distributions, which contributed to particle interlocking, jamming, and other flow issues. Electron microscopy revealed that plastic rich samples were significantly smoother, enhancing their flowability compared to the rougher, paper rich materials. Conclusions: This study establishes critical material handling baselines for processing MSW as a viable feedstock for fuel and chemical production. The findings highlight the importance of optimizing particle size and feedstock composition to improve flowability and handling performance.

09 BIOMASS FUELS↗

Vacuum probe surface sampler

A vacuum probe surface sampler is described for rapidly sampling relatively large surface areas which possess relatively light loading densities of micro-organism, drug particles or the like. A vacuum head with a hollow handle connected to a suitable vacuum source is frictionally attached to a cone assembly terminating in a flared tip adapted to be passed over the surface to be sampled. A fine mesh screen carried by the vacuum head provides support for a membrane filter which collects the microorganisms or other particles. The head assembly is easily removed from the cone assembly without contacting the cone assembly with human hands.

Zahlava, B. A.↗

Reconstructing irregularly sampled images by neural networks

Neural-network-like models of receptor position learning and interpolation function learning are being developed as models of how the human nervous system might handle the problems of keeping track of the receptor positions and interpolating the image between receptors. These models may also be of interest to designers of image processing systems desiring the advantages of a retina-like image sampling array.

Ahumada, Albert J., Jr.↗

Photon Counting Using Edge-Detection Algorithm

New applications such as high-datarate, photon-starved, free-space optical communications require photon counting at flux rates into gigaphoton-per-second regimes coupled with subnanosecond timing accuracy. Current single-photon detectors that are capable of handling such operating conditions are designed in an array format and produce output pulses that span multiple sample times. In order to discern one pulse from another and not to overcount the number of incoming photons, a detection algorithm must be applied to the sampled detector output pulses. As flux rates increase, the ability to implement such a detection algorithm becomes difficult within a digital processor that may reside within a field-programmable gate array (FPGA). Systems have been developed and implemented to both characterize gigahertz bandwidth single-photon detectors, as well as process photon count signals at rates into gigaphotons per second in order to implement communications links at SCPPM (serial concatenated pulse position modulation) encoded data rates exceeding 100 megabits per second with efficiencies greater than two bits per detected photon. A hardware edge-detection algorithm and corresponding signal combining and deserialization hardware were developed to meet these requirements at sample rates up to 10 GHz. The photon discriminator deserializer hardware board accepts four inputs, which allows for the ability to take inputs from a quadphoton counting detector, to support requirements for optical tracking with a reduced number of hardware components. The four inputs are hardware leading-edge detected independently. After leading-edge detection, the resultant samples are ORed together prior to deserialization. The deserialization is performed to reduce the rate at which data is passed to a digital signal processor, perhaps residing within an FPGA. The hardware implements four separate analog inputs that are connected through RF connectors. Each analog input is fed to a high-speed 1-bit comparator, which digitizes the input referenced to an adjustable threshold value. This results in four independent serial sample streams of binary 1s and 0s, which are ORed together at rates up to 10 GHz. This single serial stream is then deserialized by a factor of 16 to create 16 signal lines at a rate of 622.5 MHz or lower for input to a high-speed digital processor assembly. The new design and corresponding hardware can be employed with a quad-photon counting detector capable of handling photon rates on the order of multi-gigaphotons per second, whereas prior art was only capable of handling a single input at 1/4 the flux rate. Additionally, the hardware edge-detection algorithm has provided the ability to process 3-10 higher photon flux rates than previously possible by removing the limitation that photoncounting detector output pulses on multiple channels being ORed not overlap. Now, only the leading edges of the pulses are required to not overlap. This new photon counting digitizer hardware architecture supports a universal front end for an optical communications receiver operating at data rates from kilobits to over one gigabit per second to meet increased mission data volume requirements.

Gin, Jonathan W.↗

ISS External Microorganisms: A Planetary Protection Experiment to Inform Requirements for Crewed Missions to Mars

We have developed, tested, and flown a caddy capable of collecting aseptic samples from external surfaces of the ISS (International Space Station). The sampling caddy is certified for use during US EVA (extra vehicular activity) and was launched to ISS in the summer of 2023. We are scheduled to collect samples from 6 locations outside ISS during an EVA in May of 2024. We will freeze these samples at -80°C on orbit and return them to Earth. We will then extract and sequence any DNA collected during the EVA using next generation sequencing technologies to characterize the community composition and function of each sample. Measuring the type and quantity of microbes present on the exterior of ISS will allow us to address knowledge gap 2B, “Acceptable levels of microbial/organic releases from humans and support systems” described in a 2019 COSPAR report. Collecting data about microbial release from current crewed vehicles will inform requirements for acceptable leak rates for future crewed missions to Mars. The sampling kit consists of eight commercially available, sterile, DNA free, macrofoam swabs ( 23 mm. diameter ) installed in custom aluminum end effectors. Each end effector is housed in and individual aluminum canister. Each canister contains a 0.2 μm Teflon filter to allow the interior volume to accommodate pressure changes without permitting microbial contaminants to enter the sterile interior volume. A handle repurposed from the space shuttle tile repair kit is used to remove the end effector from the sample canister, collect a sample by swabbing a surface and then replace the end effector in its canister. The canisters and end effectors were cleaned and assembled on Earth. Prior to installing the sterile swab the canisters and end effectors were sterilized in an autoclave at 134°C, 215 kPA, for 7 min.. The final assembly occurred in a sterilized class II biosafety cabinet. We will collect six samples from the 1) airlock vestibule, 2) airlock thermal cover, 3) a gap in the micrometeorite shielding near the airlock, 4) a handrail near the airlock, 5) the CDRA (Carbon Dioxide Removal Assembly) vent, and 6) the VES (Vacuum Exhaust System) vent. The remaining two swabs will be reserved as controls. One swab will be exposed during the EVA without touching any surfaces to act as a blank. The final swab will remain sealed until the entire sampling kit is returned to earth. Based on previously published results from the Russian segment, we hypothesize that there will be detectable microbes at some or all of these locations. Ground-based testing of this sampling caddy confirms that the swabs remain sterile as the canisters transition in and out of vacuum. We were able to retrieve, viable bacterial and fungal cells as well as DNA from samples collected from US space suits during vacuum chamber tests lasting as long as seven hours. Based on these results and feedback from the test subjects the sampling caddy was modified to improve ergonomics and meet US EVA safety requirements. Bayonet probes were added to the sides of the sample kit as alternate mounting points. Additional locking features were added to the end effector and the filter stack to prevent inadvertent release during use. The opening mechanism was changed from one where the end effector was rocked laterally to defeat a ball detent to a twist-to-open threaded closure for similar reasons. Demonstrating, this sampling caddy’s effectiveness during a US EVA will allow us to address knowledge gaps identified in COSPAR reports and begin to define planetary protection requirements for life support systems on crewed missions to mars. This kit could also be used to collect contamination control samples during Artemis missions to verify requirements and could be easily modified for robotic sample collection.

Planetary Protection↗

ISS External Microorganisms: Collecting Planetary Protection Samples During Extravehicular Activity

We have developed, tested, and flown a caddy capable of collecting aseptic samples from external surfaces of the ISS (International Space Station). The sampling caddy is certified for use during US EVA (extra vehicular activity) and was launched to ISS in the summer of 2023. We are scheduled to collect samples from 6 locations outside ISS during an EVA in May of 2024. We will freeze these samples at -80°C on orbit and return them to Earth. We will then extract and sequence any DNA collected during the EVA using next generation sequencing technologies to characterize the community composition and function of each sample. Measuring the type and quantity of microbes present on the exterior of ISS will allow us to address knowledge gap 2B, “Acceptable levels of microbial/organic releases from humans and support systems” described in a 2019 COSPAR report. Collecting data about microbial release from current crewed vehicles will inform requirements for acceptable leak rates for future crewed missions to Mars. The sampling kit consists of eight commercially available, sterile, DNA free, macrofoam swabs ( 23 mm. diameter ) installed in custom aluminum end effectors. Each end effector is housed in and individual aluminum canister. Each canister contains a 0.2 μm Teflon filter to allow the interior volume to accommodate pressure changes without permitting microbial contaminants to enter the sterile interior volume. A handle repurposed from the space shuttle tile repair kit is used to remove the end effector from the sample canister, collect a sample by swabbing a surface and then replace the end effector in its canister. The canisters and end effectors were cleaned and assembled on Earth. Prior to installing the sterile swab the canisters and end effectors were sterilized in an autoclave at 134°C, 215 kPA, for 7 min.. The final assembly occurred in a sterilized class II biosafety cabinet. We will collect six samples from the 1) airlock vestibule, 2) airlock thermal cover, 3) a gap in the micrometeorite shielding near the airlock, 4) a handrail near the airlock, 5) the CDRA (Carbon Dioxide Removal Assembly) vent, and 6) the VES (Vacuum Exhaust System) vent. The remaining two swabs will be reserved as controls. One swab will be exposed during the EVA without touching any surfaces to act as a blank. The final swab will remain sealed until the entire sampling kit is returned to earth. Based on previously published results from the Russian segment, we hypothesize that there will be detectable microbes at some or all of these locations. Ground-based testing of this sampling caddy confirms that the swabs remain sterile as the canisters transition in and out of vacuum. We were able to retrieve, viable bacterial and fungal cells as well as DNA from samples collected from US space suits during vacuum chamber tests lasting as long as seven hours. Based on these results and feedback from the test subjects the sampling caddy was modified to improve ergonomics and meet US EVA safety requirements. Bayonet probes were added to the sides of the sample kit as alternate mounting points. Additional locking features were added to the end effector and the filter stack to prevent inadvertent release during use. The opening mechanism was changed from one where the end effector was rocked laterally to defeat a ball detent to a twist-to-open threaded closure for similar reasons. Demonstrating, this sampling caddy’s effectiveness during a US EVA will allow us to address knowledge gaps identified in COSPAR reports and begin to define planetary protection requirements for life support systems on crewed missions to mars. This kit could also be used to collect contamination control samples during Artemis missions to verify requirements and could be easily modified for robotic sample collection.

Planetary Protection↗

The 1979 Southeastern Virginia Urban Plume Study (SEV-UPS): Surface and airborne studies

The operation of two surface monitoring stations (one in downtown Norfolk, Virginia, one south of the city near the Great Dismal Swamp) and the collection of 40 hours of airborne measurements is described. Surface site measurements of ozone, oxides of nitrogen, sulfur dioxide, temperature, dew point, b sub seat, and condensation nuclei were made. Instrument calibrations, quality assurance audits, and preliminary data analysis in support of the Urban Plume Study were also made. The air pollution problems that were addressed are discussed. Data handling procedures followed for the surface stations are presented. The operation of the aircraft sampling platform is described. Aircraft sampling procedures are discussed. A preliminary descriptive analysis of the aircraft data is given along with data or plots for surface sites, airborne studies, hydrocarbon species, and instrument performance audits. Several of the aircraft flights clearly show the presence of an urban ozone plume downwind of Norfolk in the direction of the mean wind flow.

White, J. H.↗

Simulator for multilevel optimization research

A computer program designed to simulate and improve multilevel optimization techniques is described. By using simple analytic functions to represent complex engineering analyses, the simulator can generate and test a large variety of multilevel decomposition strategies in a relatively short time. This type of research is an essential step toward routine optimization of large aerospace systems. The paper discusses the types of optimization problems handled by the simulator and gives input and output listings and plots for a sample problem. It also describes multilevel implementation techniques which have value beyond the present computer program. Thus, this document serves as a user's manual for the simulator and as a guide for building future multilevel optimization applications.

Padula, S. L.↗

An experimental investigation of a low Reynolds number turbulent boundary layer subject to an adverse pressure gradient

A very low Reynolds number turbulent boundary layer subject to an adverse pressure gradient is studied. The aim is to obtain highly accurate mean-flow and turbulence measurements under conditions that can be closely related to the numerical simulations of Philippe Spalart for the purposes of CFD validation. Much of the Boundary Layer Wind Tunnel was completely rebuilt with a new wider contraction and working section which will improve compatibility with the simulations. A unique sophisticated high-speed computer controlled 3-D probe traversing mechanism was integrated into the test section. Construction of the tunnel and traverse is discussed in some detail. The hardware is now complete, and measurements are in progress. The mean-flow data indicate that a suitably two-dimensional base flow was established. Automation of the probe positioning and data acquistion have led to a decreased running time for total pressure measurements. However, the most significant benefits are expected to occur when using hot-wire probes. Calibrations can be performed automatically and there is no need to handle fragile probes when moving between measuring stations. Techniques are being developed which require sampling of the signals from moving hot-wire probes on the basis of their position in the flow. Measurements can be made in high intensity turbulence by flying probes upstream at high speed so that the relative magnitude of the turbulent velocity fluctuations are reduced. In regions, where the turbulence intensity is not too large, the probe can also be repetitively scanned across very dense spatial grids in other directions. With this technique, a complete profile can be measured in about 1/3 the time and with a spatial density about 50 times that obtainable using a stationary probe.

Watmuff, Jonathan H.↗