Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample geometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Effect of Co/SiO 2 Single-Site Heterogeneity on Small Alkane Dehydrogenation Kinetics

Atomically dispersed, high-spin Co(II) atoms in distorted tetrahedral coordination to an amorphous silica (am-SiO 2 ) support, and more recently in zeolite frameworks, are active and selective for light alkane dehydrogenation. This paper investigates how variations in the geometry of the active sites affect the ethane dehydrogenation activity of atomically dispersed Co(II) on an am-SiO 2 support. We generate a distribution of sites and determine the geometric parameters that exhibit the strongest correlation with the coordination geometry and activity of the metal atom by means of linear dimensionality reduction techniques. We perform electronic structure calculations and microkinetic modeling and deduce the mechanism and kinetics for a representative sample of sites. Irrespective of the active site geometry, the rate of ethane dehydrogenation is governed by the β-hydride elimination, which involves quartet-doublet spin-crossing and proceeds adiabatically due to strong spin-orbit coupling. Informed by the complete microkinetic analysis of the sites, we derive the reduced rate expression as a function of three site-dependent quantities. We show that these site-dependent quantities correlate with the energy of formation of the ethyl intermediate that forms via C-H bond activation. This correlation allows us to derive the site-averaged rate for the entire distribution of sites. Among various sites, the tri-coordinate and planar tetra-coordinate Co sites exhibit higher Lewis acidity than the tetrahedral sites, and consequently, higher initial rates. Finally, we discuss the implications for more active catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimal experiment design for time-lapse traveltime tomography

Geophysical monitoring techniques offer the only noninvasive approach capable of assessing both the spatial and temporal dynamics of subsurface fluid processes. Increasingly, permanent sensor arrays in boreholes and on the ocean floor are being deployed to improve the repeatability and increase the temporal sampling of monitoring surveys. Because permanent arrays require a large up-front capital investment and are difficult (or impossible) to re-configure once installed, a premium is placed on selecting a geometry capable of imaging the desired target at minimum cost. We present a simple approach to optimizing downhole sensor configurations for monitoring experiments making use of differential seismic traveltimes. In our case, we use a design quality metric based on the accuracy of tomographic reconstructions for a suite of imaging targets. By not requiring an explicit singular value decomposition of the forward operator, evaluation of this objective function scales to problems with a large number of unknowns. We also restrict the design problem by recasting the array geometry into a low dimensional form more suitable for optimization at a reasonable computational cost. We test two search algorithms on the design problem: the Nelder-Mead downhill simplex method and the Multilevel Coordinate Search algorithm. The algorithm is tested for four crosswell acquisition scenarios relevant to continuous seismic monitoring, a two parameter array optimization, several scenarios involving four parameter length/offset optimizations, and a comparison of optimal multi-source designs. In the last case, we also examine trade-offs between source sparsity and the quality of tomographic reconstructions. One general observation is that asymmetric array lengths improve localized image quality in crosswell experiments with a small number of sources and a large number of receivers. Preliminary results also suggest that high-quality differential images can be generated using only a small number of optimally positioned sources.

54 ENVIRONMENTAL SCIENCES↗

True coincidence summing corrections for an extended energy range HPGe detector

True coincidence summing (TCS) effect for natural radioactive families of U-238 and Th-232 represents a problem when an environmental sample with a close source-detector geometry measurement is performed. By using a certified multi-nuclide standard source to calibrate an energy extended range (XtRa) HPGe detector, it is possible to obtain an intensity spectrum slightly affected by the TCS effect with energies from 46 to 1836 keV. In this work, the equations and some other considerations required to calculate the TCS correction factor for isotopes of natural radioactive chains are described. It is projected a validation of the calibration, performed with the IAEA-CU-2006-03 samples (soil and water)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transmission Geometry Laser Ablation into a Non-Contact Liquid Vortex Capture Probe for Mass Spectrometry Imaging

RATIONALE: Capture of material from a laser ablation plume into a continuous flow stream of solvent provides the means for uninterrupted sampling, transport and ionization of collected material for coupling with mass spectral analysis. Reported here is the use of vertically aligned transmission geometry laser ablation in combination with a new non-contact liquid vortex capture probe coupled with electrospray ionization for spot sampling and chemical imaging with mass spectrometry. Methods: A vertically aligned continuous flow liquid vortex capture probe was positioned directly underneath a sample surface in a transmission geometry laser ablation (355 nm, 10 Hz, 7 ns pulse width) setup to capture into solution the ablated material. The outlet of the vortex probe was coupled to the Turbo V ion source of an AB SCIEX TripleTOF 5600+ mass spectrometer. System operation and performance metrics were tested using inked patterns and thin tissue sections. Glass slides and slides designed especially for laser capture microdissection, viz., DIRECTOR slides and PEN 1.0 (polyethylene naphthalate) membrane slides, were used as sample substrates. Results: The estimated capture efficiency of laser ablated material was 24%, which was enabled by the use of a probe with large liquid surface area (~ 2.8 mm2) and with gravity to help direct ablated material vertically down towards the probe. The swirling vortex action of the liquid surface potentially enhanced capture and dissolution of not only particulates, but also gaseous products of the laser ablation. The use of DIRECTOR slides and PEN 1.0 (polyethylene naphthalate) membrane slides as sample substrates enabled effective ablation of a wide range of sample types (basic blue 7, polypropylene glycol, insulin and cyctochrome c) without photodamage using a UV laser. Imaging resolution of about 6 m was demonstrated for stamped ink on DIRECTOR slides based on the ability to distinguish features present both in the optical and in the chemical image. This imaging resolution was 20 times better than the previous best reported results with laser ablation/liquid sample capture mass spectrometry imaging. Using thin sections of brain tissue the chemical image of a selected lipid was obtained with an estimated imaging resolution of about 50 um. Conclusions: A vertically aligned, transmission geometry laser ablation liquid vortex capture probe, electrospray ionization mass spectrometry system provides an effective means for spatially resolved spot sampling and imaging with mass spectrometry.

DIRECTOR slides↗

2016 NIST (133Xe) and Transfer (131mXe, 133mXe, 135Xe) Calibration Report

A significantly improved calibration of the High Purity Germanium detectors used by the Idaho National Laboratory Noble Gas Laboratory was performed during the annual NIST calibration. New sample spacers provide reproducible and secure support of samples at distances of 4, 12, 24, 50 and 100 cm. Bean, 15mL and 50mL Schlenk tube geometries were calibrated. Also included in this year’s calibration was a correlation of detector dead-time with sample activity that can be used to predict the schedule of counting the samples at each distance for each geometry. This schedule prediction will help staff members set calendar reminders so that collection of calibration data at each geometry will not be missed. This report also correlates the counting efficiencies between detectors, so that if the counting efficiency on one detector is not known, it can be estimated from the same geometry on another detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2016 NIST ( 133 Xe) and Transfer ( 131m Xe, 133m Xe, 135 Xe) Calibration Report

A significantly improved calibration of the High Purity Germanium detectors used by the Idaho National Laboratory Noble Gas Laboratory was performed during the annual NIST calibration. New sample spacers provide reproducible and secure support of samples at distances of 4, 12, 24, 50 and 100 cm. Bean, 15mL and 50mL Schlenk tube geometries were calibrated. Also included in this year’s calibration was a correlation of detector dead-time with sample activity that can be used to predict the schedule of counting the samples at each distance for each geometry. This schedule prediction will help staff members set calendar reminders so that collection of calibration data at each geometry will not be missed. This report also correlates the counting efficiencies between detectors, so that if the counting efficiency on one detector is not known, it can be estimated from the same geometry on another detector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

EFFECTS OF SIZE AND GEOMETRY ON THE EQUIBIAXIAL FLEXURAL TEST OF FINE GRAINED NUCLEAR GRAPHITE

Reduction of specimen size is an essential requirement for neutron irradiation effect studies of materials since space in nuclear reactors for those studies are often very limited and costly. Reducing the specimen size can dramatically reduce the cost of these studies, the irradiation exposure to personnel involved in post irradiation examination and the volume of radioactive waste. In this study, 4 specimen sizes were systematically varied to examine the size effect on the equibiaxial flexure test of fine grain nuclear graphite in non-irradiated conditions at room temperature. A statistically significant sample population of 30 was used for each specimen geometry or dimension. The results showed that the round shaped samples followed weibull distribution with Weibull modulus of 25 to 35. The average strength followed the trend of the weakest link theory. The 2 sizes of square shaped samples had Weibull modulus of 29 and 40. Data from round and square samples agree with others reasonably and collectively follow the Weibull scaling theory. It is concluded that the equibiaxial flexural test using adequate population of small specimens provides useful and reliable information on the statistical strength properties for fine-grained nuclear graphite materials.

Shih, Chunghao↗

Quantifying the Site Heterogeneities of Non‐Uniform Catalysts Using QuantEXAFS

Abstract We present the Multi‐site (MS) QuantEXAFS approach, designed to model the EXAFS data from samples containing an element in different local bonding geometries. Building upon our QuantEXAFS method, which maps experimental extended X‐ray absorption fine structures (EXAFS) data to DFT‐optimized structures, MS‐QuantEXAFS introduces the key capability to probe fractional contributions of multiple sites that may be present in an experimental sample. Specifically, we demonstrate effectiveness of this technique by investigating mixed samples containing known fractions of site‐isolated subsurface Pt/MgO with Pt nanoparticles uniformly supported on MgO. The ‘site‐fractions’ obtained through MS‐QuantEXAFS closely match (i. e., ±6%) the known fractions of the physically mixed samples. This approach has been generalized to other oxides, and thus represents an important advance in quantifying the speciation of non‐uniform catalyst samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Impact of Micro Porous Layer on Liquid Water Evolution inside PEMFC using Lattice Boltzmann Method

Proton exchange membrane fuel cells (PEMFCs) require a gas diffusion layer to aid in fuel transport to the catalyst sites. A microporous layer (MPL) is often added to the GDL to improve liquid saturation inside gas diffusion media. In this work, the lattice Boltzmann method was applied to four GDL samples with the addition of an MPL. Three injection orientations were used to study liquid evolution through the samples. Each orientation used four different injection pressures, ranging from 5,000 Pa to 8,000 Pa. Saturation data for GDL samples with and without an MPL were compared. Results showed that when adding an MPL, liquid tends to distribute laterally under the MPL until pressure is reached to allow liquid to travel through the cracks of the MPL surface and into the GDL geometry. A more uniform saturation distribution across the sample is seen when comparing both types of GDLs. The outcomes of this work will help research that requires knowledge of the internal liquid transport through gas diffusion media for PEMFC application.

Sepe, M.↗

Grazing exit versus grazing incidence geometry for x-ray absorption near edge structure analysis of arsenic traces

In the presented study the grazing exit x-ray fluorescence was tested for its applicability to x-ray absorption near edge structure analysis of arsenic in droplet samples. The experimental results have been compared to the findings of former analyses of the same samples using a grazing incidence (GI) setup to compare the performance of both geometries. Furthermore, the investigations were accomplished to gain a better understanding of the so called self-absorption effect, which was observed and investigated in previous studies using a GI geometry. It was suggested that a normal incidence-grazing-exit geometry would not suffer from self-absorption effects in x-ray absorption fine structure (XAFS) analysis due to the minimized path length of the incident beam through the sample. The results proved this assumption and in turn confirmed the occurrence of the self-absorption effect for GI geometry. Due to its lower sensitivity it is difficult to apply the GE geometry to XAFS analysis of trace amounts (few nanograms) of samples but the technique is well suited for the analysis of small amounts of concentrated samples.

36 MATERIALS SCIENCE↗

Regularization approach for tomosynthesis X-ray inspection

X-ray inspection is intended to be used as an escalation technique for inspection of carbon fiber reinforced plastics (CFRP) in aerospace applications, especially in case of unclear indications from ultrasonic or other NDT modalities. Due to their large dimensions, most aerospace components cannot be scanned by conventional computed tomography. In such cases, X-ray Laminography may be applied, allowing a pseudo 3D slice-by-slice reconstruction of the sample with Tomosynthesis. However, due to the limited angle acquisition geometry, reconstruction artifacts arise, especially at surfaces parallel to the imaging plane. To regularize the Tomosynthesis approach, we propose an additional prescan of the object to detect outer sample surfaces. We recommend the use of contrasted markers which are temporarily attached to the sample surfaces. The depth position of the markers is then derived from that prescan. As long as the sample surface remains simple, few markers are required to fit the respective object surfaces. The knowledge about this surface may then be used to regularize the final Tomosynthesis reconstruction, performed with markerless projections. Eventually, it can also serve as prior information for an ART reconstruction or to register a CAD model of the sample. The presented work is carried out within the European FP7 project QUICOM. We demonstrate the proposed approach within a simulation study applying an acquisition geometry suited for CFRP part inspection. A practical verification of the approach is planned later in the project.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of Passive Uptake Rates for Volatile Organic Compounds on Commercial Thermal Desorption Tubes and the Effect of Ozone on Sampling

Diffusive or passive sampling methods using commercially filled axial-sampling thermal desorption tubes are widely used for measuring volatile organic compounds (VOCs) in air. The passive sampling method provides a robust, cost effective way to measure air quality with time-averaged concentrations spanning up to a week or more. Sampling rates for VOCs can be calculated using tube geometry and Fick’s Law for ideal diffusion behavior or measured experimentally. There is evidence that uptake rates deviate from ideal and may not be constant over time. Therefore, experimentally measured sampling rates are preferred. In this project, a calibration chamber with a continuous stirred tank reactor design and constant VOC source was combined with active sampling to generate a controlled dynamic calibration environment for passive samplers. The chamber air was augmented with a continuous source of 45 VOCs ranging from pentane to diethyl phthalate representing a variety of chemical classes and physiochemical properties. Both passive and active samples were collected on commercially filled Tenax TA thermal desorption tubes over an 11-day period and used to calculate passive sampling rates. A second experiment was designed to determine the impact of ozone on passive sampling by using the calibration chamber to passively load five terpenes on a set of Tenax tubes and then exposing the tubes to different ozone environments with and without ozone scrubbers attached to the tube inlet. During the sampling rate experiment, the measured diffusive uptake was constant for up to seven days for most of the VOCs tested but deviated from linearity for some of the more volatile compounds between seven and eleven days. In the ozone experiment, both exposed and unexposed tubes showed a similar decline in terpene mass over time indicating back diffusion when uncapped tubes were transferred to a clean environment but there was no indication of significant loss by ozone reaction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of thermal history effects on mechanical anisotropy of 3D-printed polymer matrix composites via in situ X-ray tomography

The tensile behavior of an additively manufactured (AM) polymer matrix composite (PMC) is studied with in situ X-ray computed microtomography (CT) and digital volume correlation (DVC). In this experiment, the effects of recycled material content and print direction on the selective laser-sintered (SLS) material's mechanical response are explored. The PMC samples are printed in a tensile specimen geometry with gage lengths parallel to all three orthogonal, primary sintering directions. In situ tensile-CT experiments are conducted at Argonne National Laboratory's Advanced Photon Source 2-BM beamline. Analysis of the AM PMC's tensile response, failure, and strain evolution is analyzed both from a conventional standpoint, using the load-displacement data recorded by the loading fixture, and from a microstructural standpoint by applying DVC analysis to the reconstructed volumes. Significant variations on both strength and ductility are observed from both vantages with respect to print direction and the recycled material content in the printed parts. As a result, it is found that the addition of recycled source material with a thermal history reduces the tensile strength of the SLS composite for all directions, but the effect is drastic on the strength in the layering direction.

36 MATERIALS SCIENCE↗

Automated Computational Thermochemistry for Butane Oxidation: A Prelude to Predictive Automated Combustion Kinetics

arge-scale implementation of high level computational theoretical chemical kinetics offers the prospect for dramatically improving the fidelity of combustion chemical modeling. As a first step toward this goal, we developed a procedure for automatically generating the thermochemical data for combustion of an arbitrary fuel. The procedure begins by producing a list of combustion relevant species from a specification of the fuel and combustion conditions of interest. Then, for each element in the list of species, the procedure determines an internal coordinate z-matrix description of its structure, the optimal torsional configuration via Monte Carlo sampling, key rovibrational properties for that optimal geometry (including anharmonic corrections from torsional mappings and/or vibrational perturbation theory), and high level estimates of the electronic and zero-point energies via arbitrarily defined composite methods. This dataset is then converted first to partition functions, then to thermodynamic properties, and finally to NASA polynomial representations of the data. The end product is an automatically generated database of electronic structure results and thermochemical data including representations in a format appropriate for combustion simulations. The utility and functioning of this predictive automated computational thermochemistry (PACT) software package is illustrated through application to the automated generation of thermochemical data for the combustion of n-butane. Butane is chosen for this demonstration as its species list is of reasonably manageable size for debugging level computations, while still presenting most of the key challenges that need to be surmounted in the consideration of larger fuels. Furthermore, its low temperature chemistry is representative of that oc-curring with larger alkanes.

Keceli, Murat↗

Nonlinear dynamics in dusty plasmas subjected to photo-discharging

Experimental research into the control of particle charge in dusty plasmas conducted at Auburn University indicates that photocurrents generated by exposing dust to intense, near-ultraviolet light can provide a reliable and novel method of independently controlling dust charge without radically altering the background plasma; the experiment also showed that some particles may respond differently to this photo-discharge, with some exhibiting highly periodic responses to the discharge and others exhibiting chaotic behaviour. Since the dust particles in the experiment were a polydisperse sample of different sizes and shapes, particle geometry may play a role in explaining this difference. Simulations of particle discharge and dynamics are used in an attempt to reproduce experimental results and investigate a possible correlation between particle symmetry and dynamic periodicity.

McKinlay, Michael (ORCID:0000000205366269)↗

A Dataset of 3D Structural and Simulated Transport Properties of Complex Porous Media

Physical processes that occur within porous materials have wide-ranging applications including - but not limited to - carbon sequestration, battery technology, membranes, oil and gas, geothermal energy, nuclear waste disposal, water resource management. The equations that describe these physical processes have been studied extensively; however, approximating them numerically requires immense computational resources due to the complex behavior that arises from the geometrically-intricate solid boundary conditions in porous materials. Here, we introduce a new dataset of unprecedented scale and breadth, DRP-372: a catalog of 3D geometries, simulation results, and structural properties of samples hosted on the Digital Rocks Portal. The dataset includes 1736 flow and electrical simulation results on 217 samples, which required more than 500 core years of computation. This data can be used for many purposes, such as constructing empirical models, validating new simulation codes, and developing machine learning algorithms that closely match the extensive purely-physical simulation. This article offers a detailed description of the contents of the dataset including the data collection, simulation schemes, and data validation.

3D images↗

Multiple small angle neutron scattering: A new two-dimensional ultrasmall angle neutron scattering technique

We report on the demonstration experiment of the multiple small angle neutron scattering (MSANS) technique at a 5.6 m long neutron beam line, leading to a q resolution of 3x10{sup -4} A{sup -1}. The MSANS technique is based on two two-dimensional multihole apertures placed at the front end of the collimator and close to the sample, respectively. By choosing the proper MSANS geometry, individual diffraction patterns are superimposed leading to a large gain in intensity. Using MSANS as an option for standard small angle neutron scattering beam lines, the q resolution could be increased to 10{sup -5} A{sup -1} without dramatically sacrificing intensity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

X-ray absorption studies of gamma irradiated Nd doped phosphate glass

This paper presents the X-ray absorption near edge structure (XANES) studies of Nd doped phosphate glasses before and after gamma irradiation. The intensity and location of L{sub III} edge white line peak of Nd changes depending on its concentration as well as on the ratio of O/Nd in the glass matrix. The decrease in the peak intensity of white line after gamma irradiation indicates towards reduction of Nd{sup 3+} to Nd{sup 2+} in the glass matrix, which increases with an increase in the doses of gamma irradiation. Similarity in the XANES spectra of Nd doped phosphate glasses and Nd{sub 2}O{sub 3} suggests that coordination geometry around Nd{sup 3+} in glass samples may be identical to that of Nd{sub 2}O{sub 3}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗