Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Computer controlled facility for measurement of the bidirectional scattering distribution function

A computer controlled facility for measurement of the bidirectional scattering distribution function is described, with application to the evaluation of spacecraft surface contamination in optical and thermal control systems. An automatic detector/sampleholder allows a 360-deg detector scan around the sample for a complete bidirectional reflectance and transmittance distribution function characterization. The system demonstrates reduced data acquisition and reduction cycle time, and improved accuracy.

Carosso, Paolo A.↗

A laser sounder for U.S. Navy helicopters

The design and operating principles of the laser sounder developed for use in airborne coastal-zone bathymetric surveys with a U.S. Navy P-3 aircraft are described and illustrated with diagrams. The sounder components are listed and characterized, including the Nd:YAG transmitter (operating at 532 nm for bottom ranging and 1.064 microns for surface ranging), the scanning transceiver, the 10 x 6-inch-aperture controlled-FOV receiver/digitizer, the constant-fraction discriminator, the time-to-digital converter, the navigation and data-recording subsystems, and the parallel distributed processing computer (comprising a data collection and control system and a real-time processing system). Consideration is also given to the phase-I and phase-II data-reduction software being developed to process the approximately 228 million soundings to be obtained annually. The sounder can be used day or night to sound clear ocean water up to 20 m deep.

Harris, Michael M.↗

Ultrasonic Imaging Of Bond Layers Through Bond Layers

Combination of hardware and software helps ultrasonic C-scan inspection system create images of bond layer in laminated composite material, even when obscured by another bond layer. Produces image of both layers in single scan. Includes ultrasonic transducer, pulser/receiver, mechanical scanner, personal computer as controller, and electronic circuitry that gates first and second peak signals, detects peaks, and feeds resulting amplitude data to computer.

Chern, E. James↗

Germination, growth rates, and electron microscope analysis of tomato seeds flown on the LDEF

The tomato seeds were flown in orbit aboard the Long Duration Exposure Facility (LDEF) for nearly six years. During this time, the tomato seeds received an abundant exposure to cosmic radiation and solar wind. Upon the return of the LDEF to earth, the seeds were distributed throughout the United States and 30 foreign countries for analysis. The purpose of the experiment was to determine the long term effect of cosmic rays on living tissue. Our university analysis included germination and growth rates as well as Scanning Electron Microscopy and X-ray analysis of the control as well as Space-exposed tomato seeds. In analyzing the seeds under the Electron Microscope, usual observations were performed on the nutritional and epidermis layer of the seed. These layers appeared to be more porous in the Space-exposed seeds than on the Earth-based control seeds. This unusual characteristic may explain the increases in the space seeds growth pattern. (Several test results show that the Space-exposed seeds germinate sooner than the Earth-Based seeds. Also, the Space-exposed seeds grew at a faster rate). The porous nutritional region may allow the seeds to receive necessary nutrients and liquids more readily, thus enabling the plant to grow at a faster rate. Roots, leaves and stems were cut into small sections and mounted. After sputter coating the specimens with Argon/Gold Palladium Plasma, they were ready to be viewed under the Electron Microscope. Many micrographs were taken. The X-ray analysis displayed possible identifications of calcium, potassium, chlorine, copper, aluminum, silicon, phosphate, carbon, and sometimes sulfur and iron. The highest concentrations were shown in potassium and calcium. The Space-exposed specimens displayed a high concentration of copper and calcium in the two specimens. There was a significantly high concentration of copper in the Earth-based specimens, whereas there was no copper in the Space-exposed specimens.

Hammond, Ernest C., Jr.↗

Thermoelectric Control Of Temperatures Of Pressure Sensors

Prototype controlled-temperature enclosure containing thermoelectric devices developed to house electronically scanned array of pressure sensors. Enclosure needed because (1) temperatures of transducers in sensors must be maintained at specified set point to ensure proper operation and calibration and (2) sensors sometimes used to measure pressure in hostile environments (wind tunnels in original application) that are hotter or colder than set point. Thus, depending on temperature of pressure-measurement environment, thermoelectric devices in enclosure used to heat or cool transducers to keep them at set point.

Burkett, Cecil G., Jr.↗

Experimental testing using a remotely operated flap with a 2D high lift model

The problem of efficient wind tunnel testing for multi-element airfoils was first addressed by the author during a previous ASEE fellowship. A modern three element model with internal actuators to position a flap in two degrees of freedom was designed and later built. Some preliminary testing proved that the approach was viable. The purpose of this summer's work was to fully develop experimental methods including efficient data acquisition. The final goal is to develop dense data sets for both lift and drag measurements as a function of flap position for both take-off and landing configurations. The model has a span of 36 in. and chord of 18 in. and is currently being fitted for a 3 ft. x 4 ft. low speed wind tunnel. The flap was reworked to allow all pressure taps to function after initial tests showed two blocked ports. The serial method of obtaining pressures from the surface taps was found to be exceedingly slow so a new method using 12 pressure transducers and a 12 port parallel scanning valve were developed. A new automated data acquisition and control algorithm was developed using LabView software and a PC platform. Flow two-dimensionality is currently under investigation with boundary layer control by blowing; this was previously omitted for initial testing. By the end of the summer a detailed data set (uncorrected) consisting of lift coefficient versus flap position for the landing configuration should be available.

Landman, Drew↗

Fossilization processes in siliceous thermal springs: trends in preservation along thermal gradients

To enhance our ability to extract palaeobiological and palaeoenvironmental information from ancient thermal spring deposits, we have studied the processes responsible for the development and preservation of stromatolites in modern subaerial thermal spring systems in Yellowstone National Park (USA). We investigated specimens collected from silica-depositing thermal springs along the thermal gradient using petrographic techniques and scanning electron microscopy. Although it is known that thermophilic cyanobacteria control the morphogenesis of thermal spring stromatolites below 73 degrees C, we have found that biofilms which contain filamentous thermophiles contribute to the microstructural development of subaerial geyserites that occur along the inner rims of thermal spring pools and geyser effluents. Biofilms intermittently colonize the surfaces of subaerial geyserites and provide a favoured substrate for opaline silica precipitation. We have also found that the preservation of biotically produced microfabrics of thermal spring sinters reflects dynamic balances between rates of population growth, decomposition of organic matter, silica deposition and early diagenesis. Major trends in preservation of thermophilic organisms along the thermal gradient are defined by differences in the mode of fossilization, including replacement, encrustation and permineralization.

NASA Discipline Exobiology↗

Experimenting Galileo on Board the International Space Station

The SCaN Testbed is an advanced integrated communications system and laboratory facility installed on the International Space Station (ISS) in 2012. The testbed incorporates a set of new generation of Software Defined Radio (SDR) technologies intended to allow researchers to develop, test, and demonstrate new communications, networking, and navigation capabilities in the actual environment of space. Qascom, in cooperation with ESA and NASA, is designing a Software Defined Radio GalileoGPS Receiver capable to provide accurate positioning and timing to be installed on the ISS SCaN Testbed. The GalileoGPS waveform will be operated in the JPL SDR that is constituted by several hardware components that can be used for experimentations in L-Band and S-Band. The JPL SDR includes an L-Band Dorne Margolin antenna mounted onto a choke ring. The antenna is connected to a radio front end capable to provide one bit samples for the three GNSS frequencies (L1, L2 and L5) at 38 MHz, exploiting the subharmonic sampling. The baseband processing is then performed by an ATMEL AT697 processor (100 MIPS) and two Virtex 2 FPGAs. The JPL SDR supports the STRS (Space Telecommunications Radio System) that provides common waveform software interfaces, methods of instantiation, operation, and testing among different compliant hardware and software products. The standard foresees the development of applications that are modular, portable, reconfigurable, and reusable. The developed waveform uses the STRS infrastructure-provided application program interfaces (APIs) and services to load, verify, execute, change parameters, terminate, or unload an application. The project is divided in three main phases. 1)Design and Development of the GalileoGPS waveform for the SCaN Testbed starting from Qascom existing GNSS SDR receiver. The baseline design is limited to the implementation of the single frequency Galileo and GPS L1E1 receiver even if as part of the activity it will be to assess the feasibility of a dual frequency implementation (L1E1+L5E5a) in the same SDR platform.2)Qualification and test the GalileoGPS waveform using ground systems available at the NASA Glenn Research Center. Experimenters can have access to two SCaN Testbed ground based systems for development and verification: the Experimenter Development System (EDS) that is intended to provide initial opportunity for software testing and basic functional validation and the Ground Integration Unit (GIU) that is a high fidelity version of the SCaN Testbed flight system and is therefore used for more controlled final development testing and verification testing.3)Perform in-orbit validation and experimentation: The experimentation phase will consists on the collection of raw measurements (pseudorange, Carrier phase, CN0) in space, assessment on the quality of the measurements and the receiver performances in terms of signal acquisition, tracking, etc. Finally computation of positioning in space (Position, Velocity and time) and assessment of its performance.(Complete abstract in attached document).

GPS↗

Experimenting Galileo on Board the International Space Station

The SCaN Testbed is an advanced integrated communications system and laboratory facility installed on the International Space Station (ISS) in 2012. The testbed incorporates a set of new generation of Software Defined Radio (SDR) technologies intended to allow researchers to develop, test, and demonstrate new communications, networking, and navigation capabilities in the actual environment of space. Qascom, in cooperation with ESA and NASA, is designing a Software Defined Radio GalileoGPS Receiver capable to provide accurate positioning and timing to be installed on the ISS SCaN Testbed. The GalileoGPS waveform will be operated in the JPL SDR that is constituted by several hardware components that can be used for experimentations in L-Band and S-Band. The JPL SDR includes an L-Band Dorne Margolin antenna mounted onto a choke ring. The antenna is connected to a radio front end capable to provide one bit samples for the three GNSS frequencies (L1, L2 and L5) at 38 MHz, exploiting the subharmonic sampling. The baseband processing is then performed by an ATMEL AT697 processor (100 MIPS) and two Virtex 2 FPGAs. The JPL SDR supports the STRS (Space Telecommunications Radio System) that provides common waveform software interfaces, methods of instantiation, operation, and testing among different compliant hardware and software products. The standard foresees the development of applications that are modular, portable, reconfigurable, and reusable. The developed waveform uses the STRS infrastructure-provided application program interfaces (APIs) and services to load, verify, execute, change parameters, terminate, or unload an application. The project is divided in three main phases. 1)Design and Development of the GalileoGPS waveform for the SCaN Testbed starting from Qascom existing GNSS SDR receiver. The baseline design is limited to the implementation of the single frequency Galileo and GPS L1E1 receiver even if as part of the activity it will be to assess the feasibility of a dual frequency implementation (L1E1+L5E5a) in the same SDR platform.2)Qualification and test the GalileoGPS waveform using ground systems available at the NASA Glenn Research Center. Experimenters can have access to two SCaN Testbed ground based systems for development and verification: the Experimenter Development System (EDS) that is intended to provide initial opportunity for software testing and basic functional validation and the Ground Integration Unit (GIU) that is a high fidelity version of the SCaN Testbed flight system and is therefore used for more controlled final development testing and verification testing.3)Perform in-orbit validation and experimentation: The experimentation phase will consists on the collection of raw measurements (pseudorange, Carrier phase, CN0) in space, assessment on the quality of the measurements and the receiver performances in terms of signal acquisition, tracking, etc. Finally computation of positioning in space (Position, Velocity and time) and assessment of its performance.(Complete abstract in attached document).

Galileo↗

Improvements to In-Canal Assay of High Specific Activity 60Co at the ATR

Improvements to the quality of measurements in the assaying of High Specific Activity (HSA) cobalt 60 produced at the Advanced Test Reactor at the Idaho National Laboratory are presented. Such assays are conducted regularly between cycles at the ATR, and due to the radiological safety concerns, they are performed within the ATR canal. A standard ion chamber detector was placed in a collimated assay tube within the canal. Another tube, parallel to the detector, was used to position various cobalt 60 standards and targets. The collimated port between these tubes allows for the targets to be pulled across via a winch system. Previous measurements were performed at discrete 1.5-inch steps using a hand-cranked winch system. Charge was collected and integrated for 10 seconds at each discrete step during a scan. Two substantial improvements to the assay include an electronically controlled, motor-driven winch system and a software controlled continuous charge collection. Combined, these changes improved the quality of measurements as well as streamline the assay process. Further examination of these charge profiles indicated a reasonable amount of photon scattering, or shine, before a line-of-sight is established. This created inaccuracies in the reported activity of the cobalt targets. A series of MCNP-6.3 calculations were performed in an effort to quantify and correct for this shine effect. The results of the calculations and how they were employed to a create shine correction factor for the in-canal cobalt assay at the ATR are presented. The overall bias showed an overestimation of the HSA cobalt 60 activity by around 7-8%.

07 - ISOTOPES AND RADIATION SOURCES↗

Optical tuning of the diamond Fermi level measured by correlated scanning probe microscopy and quantum defect spectroscopy

Quantum technologies based on quantum point defects in crystals require control over the defect charge state. Here we tune the charge state of shallow nitrogen-vacancy and silicon-vacancy centers by locally oxidizing a hydrogenated surface with moderate optical excitation and simultaneous spectral monitoring. The loss of conductivity and change in work function due to oxidation are measured in atmosphere using conductive atomic force microscopy and Kelvin probe force microscopy (KPFM). We correlate these scanning probe measurements with optical spectroscopy of the nitrogen-vacancy and silicon-vacancy centers created via implantation 15–25 nm beneath the diamond surface and annealing. The observed charge state of the defects as a function of optical exposure demonstrates that laser oxidation provides a way to precisely tune the Fermi level over a range of at least 2.00 eV. We also observe a significantly larger oxidation rate for implanted surfaces compared to unimplanted surfaces under ambient conditions. Here, combined with knowledge of the electron affinity of a surface, these results suggest KPFM is a powerful, high-spatial-resolution technique to advance surface Fermi level engineering for charge stabilization of quantum defects.

36 MATERIALS SCIENCE↗

Atomic Manipulation of Single Erbium on GaAs(110): From Adatom Motion to Creation and Control of Bistable Substitutions

We demonstrate atomic-scale control over the position and configuration of single erbium (Er) atoms at the GaAs(110) surface using scanning tunneling microscopy (STM). By applying voltage pulses from the STM tip, we drive Er adatoms to move sequentially among three distinct adsorption sites and controllably substitute into Ga lattice sites. The resulting substitutional Er atoms exhibit two isoelectronic configurations that differ by less than one angstrom in lateral position and can be reversibly switched by additional voltage pulses. Differential conductance spectroscopy shows differences in the unoccupied local electronic states for the two substitutional configurations, and an absence of mid-gap states. Preliminary density functional theory (DFT) calculations support these findings, identifying the most stable adsorption and substitutional sites, their relative binding energies, charge states, and local density of states (LDOS) characteristics. Together, the experimental and theoretical results establish a method for precise, reversible manipulation of rare-earth dopants at semiconductor surfaces, opening a pathway to engineer atomic-scale quantum and optoelectronic functionalities.

Poche, Steven [Ohio State University]↗

High-Performance Scanning Acousto-Ultrasonic System

A high-performance scanning acousto-ultrasonic system, now undergoing development, is designed to afford enhanced capabilities for imaging microstructural features, including flaws, inside plate specimens of materials. The system is expected to be especially helpful in analyzing defects that contribute to failures in polymer- and ceramic-matrix composite materials, which are difficult to characterize by conventional scanning ultrasonic techniques and other conventional nondestructive testing techniques. Selected aspects of the acousto-ultrasonic method have been described in several NASA Tech Briefs articles in recent years. Summarizing briefly: The acousto-ultrasonic method involves the use of an apparatus like the one depicted in the figure (or an apparatus of similar functionality). Pulses are excited at one location on a surface of a plate specimen by use of a broadband transmitting ultrasonic transducer. The stress waves associated with these pulses propagate along the specimen to a receiving transducer at a different location on the same surface. Along the way, the stress waves interact with the microstructure and flaws present between the transducers. The received signal is analyzed to evaluate the microstructure and flaws. The specific variant of the acousto-ultrasonic method implemented in the present developmental system goes beyond the basic principle described above to include the following major additional features: Computer-controlled motorized translation stages are used to automatically position the transducers at specified locations. Scanning is performed in the sense that the measurement, data-acquisition, and data-analysis processes are repeated at different specified transducer locations in an array that spans the specimen surface (or a specified portion of the surface). A pneumatic actuator with a load cell is used to apply a controlled contact force. In analyzing the measurement data for each pair of transducer locations in the scan, the total (multimode) acousto-ultrasonic response of the specimen is utilized. The analysis is performed by custom software that extracts parameters of signals in the time and frequency domains. The computer hardware and software provide both real-time and postscan processing and display options. For example, oscilloscope displays of waveforms and power spectral densities are available in real time. Images can be computed while scanning continues. Signals can be digitally preprocessed and/or post-processed by filtering, windowing, time-segmenting, and running-waveform-averaging algorithms. In addition, the software affords options for off-line simulation of the waveform-data-acquisition and scanning processes. In tests, the system has been shown to be capable of characterizing microstructural changes and defects in SiC/SiC and C/SiC ceramic-matrix composites. Delaminations, variations in density, microstructural changes attributable to infiltration by silicon, and crack-space indications (defined in the next sentence) have been revealed in images formed from several time- and frequency-domain parameters of scanning acousto-ultrasonic signals. The crack-space indications were image features that were not revealed by other nondestructive testing methods and are so named because they turned out to mark locations where cracking eventually occurred.

Roth, Don↗

Hybrid manufacturing by additive friction stir deposition, metrology, CNC machining, and microstructure analysis

Aerospace flight panels must provide high strength with low mass. For aluminum panels, it is common practice to begin with a wrought plate and remove the majority of the material to attain the desired structure, comprising a thinner plate with the desired pattern of reinforcement ribs. As an alternative, this study implements hybrid manufacturing, where aluminum is first deposited on a baseplate only at the rib locations using additive friction stir deposition (AFSD). Structured light scanning is then used to measure the printed geometry. This geometry is finally used as the stock model for computer numerical control (CNC) machining. This paper details the hybrid manufacturing process that consists of: AFSD to print the preform, structured light scanning to generate the stock model and tool path, three-axis CNC machining, and post-process measurements for part geometry and microstructure.

42 ENGINEERING↗

Field Testing of High Current Electrokinetic Nanoparticle Treatment for Corrosion Mitigation in Reinforced Concrete

Electrokinetic Nanoparticle (EN) treatment was used as a rapid repair measure to mitigate chloride induced corrosion of reinforced concrete in the field. EN treatment uses an electric field to transport positively charged nanoparticles to the reinforcement through the concrete capillary pores. Cylindrical reinforced concrete specimens were batched with 4.5 wt % salt content (based on cement mass). Three distinct electrokinetic treatments were conducted using high current density (up to 5 A/m2) to form a chloride penetration barrier that was established in 5 days, as opposed to the traditional 6-8 weeks, generally required for electrochemical chloride extraction (ECE). These treatments included basic EN treatment, EN with additional calcium treatment, and basic ECE treatment. Field exposures were conducted at the NASA Beachside Corrosion Test Site, Kennedy Space Center, Florida, USA. The specimens were subjected to sea water immersion at the test site as a posttreatment exposure. Following a 30-day post-treatment exposure period, the specimens were subjected to indirect tensile testing to evaluate treatment impact. The EN treated specimens exhibited 60% and 30% increases in tensile strength as compared to the untreated controls and ECE treated specimens respectively. The surfaces of the reinforcement bars of the control specimens were 67% covered by corrosion products. In contrast, the EN treated specimens exhibited corrosion coverage of only 4%. Scanning electron microscopy (SEM) revealed a dense concrete microstructure adjacent to the bars of the treated specimens as compared to the control and ECE specimens. Energy dispersive spectroscopic (EDS) analysis of the polished EN treated specimens showed a reduction in chloride content by a factor of 20 adjacent to the bars. This study demonstrated that EN treatment was successful in forming a chloride penetration barrier rapidly. This work also showed that the chloride barrier was effective when samples were exposed to field conditions at one of the most severely corrosive environments in North America.

Cardenas, Henry↗

A Near IR Fabry-Perot Interferometer for Wide Field, Low Resolution Hyperspectral Imaging on the Next Generation Space Telescope

We discuss work in progress on a near-infrared tunable bandpass filter for the Goddard baseline wide field camera concept of the Next Generation Space Telescope (NGST) Integrated Science Instrument Module (ISIM). This filter, the Demonstration Unit for Low Order Cryogenic Etalon (DULCE), is designed to demonstrate a high efficiency scanning Fabry-Perot etalon operating in interference orders 1 - 4 at 30K with a high stability DSP based servo control system. DULCE is currently the only available tunable filter for lower order cryogenic operation in the near infrared. In this application, scanning etalons will illuminate the focal plane arrays with a single order of interference to enable wide field lower resolution hyperspectral imaging over a wide range of redshifts. We discuss why tunable filters are an important instrument component in future space-based observatories.

Barry, R. K.↗

High‐throughput combinatorial approach expedites the synthesis of a lead‐free relaxor ferroelectric system

Abstract Developing novel lead‐free ferroelectric materials is crucial for next‐generation microelectronic technologies that are energy efficient and environment friendly. However, materials discovery and property optimization are typically time‐consuming due to the limited throughput of traditional synthesis methods. In this work, we use a high‐throughput combinatorial synthesis approach to fabricate lead‐free ferroelectric superlattices and solid solutions of (Ba 0.7 Ca 0.3 )TiO 3 (BCT) and Ba(Zr 0.2 Ti 0.8 )O 3 (BZT) phases with continuous variation of composition and layer thickness. High‐resolution x‐ray diffraction (XRD) and analytical scanning transmission electron microscopy (STEM) demonstrate high film quality and well‐controlled compositional gradients. Ferroelectric and dielectric property measurements identify the “optimal property point” achieved at the composition of 48BZT–52BCT. Displacement vector maps reveal that ferroelectric domain sizes are tunable by varying {BCT–BZT} N superlattice geometry. This high‐throughput synthesis approach can be applied to many other material systems to expedite new materials discovery and properties optimization, allowing for the exploration of a large area of phase space within a single growth. image

36 MATERIALS SCIENCE↗

Flexible Multiplexed Surface Temperature Sensor

Unitary array of sensors measures temperatures at points distributed over designated area on surface. Useful in measuring surface temperatures of aerodynamic models and thermally controlled objects. Made of combination of integrated-circuit microchips and film circuitry. Temperature-sensing chips scanned at speeds approaching 10 kHz. Operating range minus 40 degrees C to 120 degrees C. Flexibility of array conforms to curved surfaces. Multiplexer eliminates numerous monitoring cables. Control of acquisition and recording of data effected by connecting array to microcomputers via suitable interface circuitry.

Daryabeigi, Kamran↗