Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensitivity Matrix”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Mass Spectrometry Imaging of Bio‐oligomer Polydispersity in Plant Tissues by Laser Desorption Ionization from Silicon Nanopost Arrays

Abstract Mass spectrometry imaging (MSI) enables simultaneous spatial mapping for diverse molecules in biological tissues. Matrix‐assisted laser desorption ionization (MALDI) mass spectrometry (MS) has been a mainstream MSI method for a wide range of biomolecules. However, MALDI‐MSI of biological homopolymers used for energy storage and molecular feedstock is limited by, e.g., preferential ionization for certain molecular classes. Matrix‐free nanophotonic ionization from silicon nanopost arrays (NAPAs) is an emerging laser desorption ionization (LDI) platform with ultra‐trace sensitivity and molecular imaging capabilities. Here, we show complementary analysis and MSI of polyhydroxybutyric acid (PHB), polyglutamic acid (PGA), and polysaccharide oligomers in soybean root nodule sections by NAPA‐LDI and MALDI. For PHB, number and weight average molar mass, polydispersity, and oligomer size distributions across the tissue section and in regions of interest were characterized by NAPA‐LDI‐MSI.

Samarah, Laith Z.↗

Electric dipole moment constraints on CP-violating heavy-quark Yukawas at next-to-leading order

Electric dipole moments are sensitive probes of new phases in the Higgs Yukawa couplings. We calculate the complete two-loop QCD anomalous dimension matrix for the mixing of CP-odd scalar and tensor operators and apply our results for a phenomenological study of CP violation in the bottom and charm Yukawa couplings. We find large shifts of the induced Wilson coefficients at next-to-leading-logarithmic order. Using the experimental bound on the electric dipole moments of the neutron and mercury, we update the constraints on CP-violating phases in the bottom and charm quark Yukawas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-loop electroweak corrections to the Top-Quark Contribution to ϵ K

The parameter ϵ K measures CP violation in the neutral kaon system. It is a sensitive probe of new physics and plays a prominent role in the global fit of the Cabibbo-Kobabyashi-Maskawa matrix. The perturbative theory uncertainty is currently dominated by the top-quark contribution. Here, we present the calculation of the full two-loop electroweak corrections to the top-quark contribution to ϵ K , including the resummation of QED-QCD logarithms. We discuss different renormalization prescriptions for the electroweak input parameters. In the traditional normalization of the weak Hamiltonian with two powers of the Fermi constant G F , the top-quark contribution is shifted by –1%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NF-{kappa}B signaling is activated and confers resistance to apoptosis in three-dimensionally cultured EGFR-mutant lung adenocarcinoma cells

Highlights: Black-Right-Pointing-Pointer EGFR-mutant cells in 3D culture resist EGFR inhibition compared with suspended cells. Black-Right-Pointing-Pointer Degradation of I{kappa}B and activation of NF-{kappa}B are observed in 3D-cultured cells. Black-Right-Pointing-Pointer Inhibiting NF-{kappa}B enhances the efficacy of the EGFR inhibitor in 3D-cultured cells. -- Abstract: Epidermal growth factor receptor (EGFR)-mutant lung adenocarcinoma cells in suspension undergo apoptosis to a greater extent than adherent cells in a monolayer when EGFR autophosphorylation is inhibited by EGFR tyrosine kinase inhibitors (TKIs). This suggests that cell adhesion to a culture dish may activate an anti-apoptotic signaling pathway other than the EGFR pathway. Since the microenvironment of cells cultured in a monolayer are substantially different to that of cells existing in three-dimension (3D) in vivo, we assessed whether two EGFR-mutant lung adenocarcinoma cell lines, HCC827 and H1975, were more resistant to EGFR TKI-induced apoptosis when cultured in a 3D extracellular matrix (ECM) as compared with in suspension. The ECM-adherent EGFR-mutant cells in 3D were significantly less sensitive to treatment with WZ4002, an EGFR TKI, than the suspended cells. Further, a marked degradation of I{kappa}B{alpha}, the inhibitor of nuclear factor (NF)-{kappa}B, was observed only in the 3D-cultured cells, leading to an increase in the activation of NF-{kappa}B. Moreover, the inhibition of NF-{kappa}B with pharmacological inhibitors enhanced EGFR TKI-induced apoptosis in 3D-cultured EGFR-mutant cells. These results suggest that inhibition of NF-{kappa}B signaling would render ECM-adherent EGFR-mutant lung adenocarcinoma cells in vivo more susceptible to EGFR TKI-induced cell death.

60 APPLIED LIFE SCIENCES↗

Frequency upconversion in Er{sup 3+} doped Y{sub 2}O{sub 3} nanophosphor:Yb{sup 3+} sensitization and tailoring effect of Li{sup +} ion

Graphical abstract: - Highlights: • Dual mode luminescence behavior of Er{sup 3+} in oxide phosphor. • Sensitization through Yb{sup 3+} codoping, and tailoring effect of lithium ion. • Phosphors for lighting and display applications. - Abstract: Er{sup 3+} doped Y{sub 2}O{sub 3} nanophosphor has been synthesized using solution combustion technique and further characterized for structure and optical properties. Optical properties of Er{sup 3+} ion have been studied both through frequency upconversion (UC) as well as through fluorescence (excitation, emission, and CIE co-ordinate analysis) processes. Further to enhance the UC emission of Er{sup 3+} ions, a two step process has been used. In the first step, Yb{sup 3+} ion has been co-doped, which acts as the sensitizer for Er{sup 3+} through energy transfer process. In the second step, different concentrations of Li{sup +} ions have been co-doped in the Er{sup 3+}/Yb{sup 3+}:Y{sub 2}O{sub 3} system. Fourier transform infrared analysis, and X-ray diffraction (XRD) followed by Le-Bail refinement of the XRD data reveal that the co-doping of Li{sup +} ion decreases unit cell parameter, increases the particle size, and removes the quenching centers (like OH, NO{sub x}, etc.), which all together causes a significant enhancement in UC emission. Optimum UC luminescence is attained for 5 mol% Li{sup +} doping concentration beyond which a quenching in UC emission is observed. This combined approach, i.e. Yb{sup 3+} sensitization and Li{sup +} ion tailoring simultaneously enhances the UC emission intensity of Er{sup 3+} several times in yttria matrix effectively. The strategy can be generalized in other hosts also which could help in the development of efficient photonic materials for lighting and display devices.

36 MATERIALS SCIENCE↗

Imaging Nicotine in Rat Brain Tissue by Use of Nanospray Desorption Electrospray Ionization Mass Spectrometry

Imaging mass spectrometry offers simultaneous detection of drugs, drug metabolites and endogenous substances in a single experiment. This is important when evaluating effects of a drug on a complex organ system such as the brain, where there is a need to understand how regional drug distribution impacts function. Nicotine is an addictive drug and its action in the brain is of high interest. Here we use nanospray desorption electrospray ionization, nano-DESI, imaging to discover the localization of nicotine in rat brain tissue after in vivo administration of nicotine. Nano-DESI is a new ambient technique that enables spatially-resolved analysis of tissue samples without special sample pretreatment. We demonstrate high sensitivity of nano-DESI imaging that enables detection of only 0.7 fmole nicotine per pixel in the complex brain matrix. Furthermore, by adding deuterated nicotine to the solvent, we examined how matrix effects, ion suppression, and normalization affect the observed nicotine distribution. Finally, we provide preliminary results suggesting that nicotine localizes to the hippocampal substructure called dentate gyrus.

dentate gyrus↗

DARK MATTER SUBSTRUCTURE DETECTION USING SPATIALLY RESOLVED SPECTROSCOPY OF LENSED DUSTY GALAXIES

We investigate how strong lensing of dusty, star-forming galaxies (DSFGs) by foreground galaxies can be used as a probe of dark matter halo substructure. We find that spatially resolved spectroscopy of lensed sources allows dramatic improvements to measurements of lens parameters. In particular, we find that modeling of the full, three-dimensional (angular position and radial velocity) data can significantly facilitate substructure detection, increasing the sensitivity of observables to lower mass subhalos. We carry out simulations of lensed dusty sources observed by early ALMA (Cycle 1) and use a Fisher matrix analysis to study the parameter degeneracies and mass detection limits of this method. We find that even with conservative assumptions, it is possible to detect galactic dark matter subhalos of {approx}10{sup 8} M{sub Sun} with high significance in most lensed DSFGs. Specifically, we find that in typical DSFG lenses, there is a {approx}55% probability of detecting a substructure with M > 10{sup 8} M{sub Sun} with more than 5{sigma} detection significance in each lens, if the abundance of substructure is consistent with previous lensing results. The full ALMA array, with its significantly enhanced sensitivity and resolution, should improve these estimates considerably. Given the sample of {approx}100 lenses provided by surveys such as the South Pole Telescope, our understanding of dark matter substructure in typical galaxy halos is poised to improve dramatically over the next few years.

79 ASTRONOMY AND ASTROPHYSICS↗

Observation of quantum entanglement in top quark pair production in proton–proton collisions at $\sqrt{s}$ = 13 TeV

Entanglement is an intrinsic property of quantum mechanics and is predicted to be exhibited in the particles produced at the Large Hadron Collider. A measurement of the extent of entanglement in top quark-antiquark ($t\bar{t}$) events produced in proton–proton collisions at a center-of-mass energy of 13 TeV is performed with the data recorded by the CMS experiment at the CERN LHC in 2016, and corresponding to an integrated luminosity of 36.3 fb −1 . The events are selected based on the presence of two leptons with opposite charges and high transverse momentum. An entanglement-sensitive observable D is derived from the top quark spin-dependent parts of the $t\bar{t}$ production density matrix and measured in the region of the $t\bar{t}$ production threshold. Values of $D \lt -1/3$ are evidence of entanglement and D is observed (expected) to be $-0.480^{+0.026}_{-0.029}$ ($-0.467^{+0.026}_{-0.029}$) at the parton level. With an observed significance of 5.1 standard deviations with respect to the non-entangled hypothesis, this provides observation of quantum mechanical entanglement within $t\bar{t}$ pairs in this phase space. This measurement provides a new probe of quantum mechanics at the highest energies ever produced.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dynamic X-ray diffraction imaging of the ferroelectric response in bismuth ferrite

Abstract X-ray diffraction imaging is rapidly emerging as a powerful technique by which one can capture the local structure of crystalline materials at the nano- and meso-scale. Here, we present investigations of the dynamic structure of epitaxial monodomain BiFeO 3 thin-films using a novel full-field Bragg diffraction imaging modality. By taking advantage of the depth penetration of hard X-rays and their exquisite sensitivity to the atomic structure, we imaged in situ and in operando, the electric field-driven structural responses of buried BiFeO 3 epitaxial thin-films in micro-capacitor devices, with sub-100 nm lateral resolution. These imaging investigations were carried out at acquisition frame rates that reached up to 20 Hz and data transfer rates of 40 MB/s, while accessing diffraction contrast that is sensitive to the entire three-dimensional unit cell configuration. We mined these large datasets for material responses by employing matrix decomposition techniques, such as independent component analysis. We found that this statistical approach allows the extraction of the salient physical properties of the ferroelectric response of the material, such as coercive fields and transient spatiotemporal modulations in their piezoelectric response, and also facilitates their decoupling from extrinsic sources that are instrument specific.

36 MATERIALS SCIENCE↗

Development of Standards for NanoSIMS Analyses of Biological Materials

NanoSIMS is a powerful analytical technique for investigating element distributions at the nanometer scale, but quantifying elemental abundances requires appropriate standards, which are not readily available for biological materials. Standards for trace element analyses have been extensively developed for secondary ion mass spectrometry (SIMS) in the semiconductor industry and in the geological sciences. The three primary approaches for generating standards for SIMS are: (1) ion implantation (2) using previously characterized natural materials, and (3) preparing synthetic substances. Ion implantation is a reliable method for generating trace element standards, but it is expensive, which limits investigation of the analytical issues discussed above. It also requires low background levels of the elements of interest. Finding or making standard materials has the potential to provide more flexibility than ion implantation, but realizing homogeneity at the nano-scale is in itself a significant challenge. In this study, we experiment with all three approaches, but with an emphasis toward synthetic organic polymers in order to reduce costs, increase flexibility, and achieve a wide dynamic concentration range. This emphasis serves to meet the major challenge for biological samples of identifying matrix matched, homogeneous material. Biological samples themselves are typically heterogeneous at the scale of microns to 100s of microns, and therefore they are poor SIMS standards. Therefore, we focused on identifying 'biological-like' materials--either natural or synthetic--that can be used for standards. The primary criterion is that the material be as compositionally similar to biological samples as possible (primarily C, H, O, and N). For natural material we adsorbed organic colloids consisting of peptidoglycan (i.e., amino sugars), activated charcoal, and humic acids. Experiments conducted with Si on peptidoglycan showed low affinity as SiO{sub 2}, yet its distribution in the matrix was similar to that observed in spores. In experiments with Mo on humic acid, homogeneity was achieved and a sensitivity factor relative to C was determined. For synthetic material, we successfully prepared polyacrylic acid containing complexed elements of Mo, Ca, Sr, and Ba at low abundance. These were prepared as aqueous mixtures of dissolved elements and polyacrylic resin, followed by thin film drying. The Mo was homogeneously distributed and yielded a relative sensitivity factor nearly identical to that calculated for humic acid. This approach shows great promise for most water soluble metals. Poly(methacrylate) thin films were prepared that contained different low-level concentrations of Si introduced as a silane compound. Although homogeneity was not fully achieved, the analytical results did validate our previous quantitative methodology for Si. In addition, Commercial plastics were also examined for suitability for F and Cl. We found food-grade polyvinyl tubing produced high precision Cl determinations. For ion implantation, we used epoxy as the substrate and successfully extracted depth profiles and sensitivity factors for F and Cu.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

B-jet and c-jet identification with Neural Networks as well as combination of multivariate analyses for the search for of multivariate analyses for the search for single top-quark production

In the first part of this diploma thesis, the current version of the KIT Flavor Separator, a neural network which is able to distinguish between tagged b-quark jets and tagged c/light-quark jets, is presented. In comparison with previous versions four new input variables are utilized and new Monte Carlo samples with a larger number of simulated events are used for the training of the neural network. It is illustrated that the output of the neural network is continuously distributed between 1 and -1, whereas b-quark jets accumulate at 1, however, c-quark jets and light-quark jets have outputs next to -1. To ensure that the network output describes observed events correctly, the shapes of all input variables are compared in simulation and data. Thus the mismodelling of any input variable is excluded. Moreover, the b jet and light jet output distributions are compared with the output of samples of observed events, which are enhanced in the particular flavor. In contrast to previous versions, no b-jet output correction function has to be calculated, because the agreement between simulation and collision data is excellent for b-quark jets. For the light-jet output, correction functions are developed. Different applications of the KIT Flavor Separator are mentioned. For example it provides a precious input to all three CDF single top quark analyses. Furthermore, it is shown that the KIT Flavor Separator is a universal tool, which can be used in every high-p{sub T} analysis that requires the identification of b-quark jets with high efficiency. As it is pointed out, a further application is the estimation of the flavor composition of a given sample of observed events. In addition a neural network, which is able to separate c-quark jets from light-quark jets, is trained. It is shown, that all three flavors can be separated in the c-net-Flavor Separator plane. As a result, the uncertainties on the estimation of the flavor composition in events with one tagged jet are cut into half. In the second part of this diploma thesis, a method for the combination of three multivariate single-top analyses using an integrated luminosity of 2.2 fb{sup -1} is presented. For this purpose the discriminants of the Likelihood Function analysis, the Matrix Element method and the Neural Network analysis are used as input variables to a neural network. Overall four different networks are trained, one for events with two or three jets and one or two SecVtx tags, respectively. Using a binned likelihood function, the outputs of these networks are fitted to the output distribution of observed events. A single top-quark production cross section of {sigma}{sub single-top} = 2.2{sub -0.7}{sup +0.8} pb is measured. Ensemble tests are performed for the calculation of the sensitivity and observed significance, which are found to be 4.8{sigma} and 3.9{sigma}, respectively. Hence the improvement of this combination is roughly 8% in comparison with sensitivities found by the individual analyses. Due to the proportionality of {sigma}{sub single-top} and |V{sub tb}|{sup 2} and under the assumption V{sub tb} >> V{sub ts}, V{sub td}, a value for |V{sub tb}| is quoted: |V{sub tb}| = 0.88{sub -0.12}{sup +0.14}(exp.) {+-} 0.07(theo.). It can be seen, that the given uncertainties are too large for a verification or falsification of the unitarity assumption of the CKM-matrix. Parallel to this combination a further combination method (NEAT-combination) has been developed. This combination uses a neural network trained with a neuroevolution technique, which optimizes the neural network architecture and weights through the use of genetic algorithms. In this analysis an improvement of roughly 12% could be reached. In figure 7.1 the current situation for the measurement of the single top-quark production cross section is summarized. After collecting more data, CDF will be able to observe single top-quark production with a significance larger than 5.0{sigma}. Nevertheless, the cross section measurement will still have large uncertainties on the level of 20%. Precise measurements on the few percent level will only be possible at the LHC. Recent studies for the CMS detector showed, that the t-channel cross section can be measured with an accuracy of 7% in 1 fb{sup -1} of LHC data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monte Carlo based investigation of Berry phase for depth resolved characterization of biomedical scattering samples

The propagation of light in turbid media is an active area of research with relevance to numerous investigational fields, e.g., biomedical diagnostics and therapeutics. The statistical random-walk nature of photon propagation through turbid media is ideal for computational based modeling and simulation. Ready access to super computing resources provide a means for attaining brute force solutions to stochastic light-matter interactions entailing scattering by facilitating timely propagation of sufficient (>10million) photons while tracking characteristic parameters based on the incorporated physics of the problem. One such model that works well for isotropic but fails for anisotropic scatter, which is the case for many biomedical sample scattering problems, is the diffusion approximation. In this report, we address this by utilizing Berry phase (BP) evolution as a means for capturing anisotropic scattering characteristics of samples in the preceding depth where the diffusion approximation fails. We extend the polarization sensitive Monte Carlo method of Ramella-Roman, et al.,1 to include the computationally intensive tracking of photon trajectory in addition to polarization state at every scattering event. To speed-up the computations, which entail the appropriate rotations of reference frames, the code was parallelized using OpenMP. The results presented reveal that BP is strongly correlated to the photon penetration depth, thus potentiating the possibility of polarimetric depth resolved characterization of highly scattering samples, e.g., biological tissues.

back scattered Mueller matrix↗

RAPID: The Development and Application of a Hybrid High Pressure Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry Method for the Direct Analysis of Irradiated Materials

RAPID (Rapid Analysis of Post-Irradiation Debris) is an automated online separation–direct analysis method developed at Oak Ridge National Laboratory (ORNL) to measure both radioactive and stable fission isotopes by mass. Developed to measure the concentration and isotopic composition of over 40 elements down to the femtogram level, RAPID demonstrates the sensitivity, stability, and precision required to achieve accurate, low-level analyses of elements of non-natural origin. The application of the RAPID method to silica- and soil-based matrices achieved complete matrix exclusion and direct online analysis of the elementally separated analytes, yielding precise isotopic compositions. When combined with isotope dilution, this approach yielded elemental concentrations with low uncertainties, providing a rapid analytical method that encompasses group I and II metals, transition metals, refractory metals, platinum group metals, lanthanides, and actinides. The robustness, sensitivity, reproducibility, and numerous applications to a number of fields in nuclear measurements have been confirmed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A fast, matrix-based method to perform omnidirectional pressure integration

Abstract Experimentally-measured pressure fields play an important role in understanding many fluid dynamics problems. Unfortunately, pressure fields are difficult to measure directly with non-invasive, spatially resolved diagnostics, and calculations of pressure from velocity have proven sensitive to error in the data. Omnidirectional line integration methods are usually more accurate and robust to these effects as compared to implicit Poisson equations, but have seen slower uptake due to the higher computational and memory costs, particularly in 3D domains. This paper demonstrates how omnidirectional line integration approaches can be converted to a matrix inversion problem. This novel formulation uses an iterative approach so that the boundary conditions are updated each step, preserving the convergence behavior of omnidirectional schemes while also keeping the computational efficiency of Poisson solvers. This method is implemented in Matlab and also as a GPU-accelerated code in CUDA-C++. The behavior of the new method is demonstrated on 2D and 3D synthetic and experimental data. Three-dimensional grid sizes of up to 125 million grid points are tractable with this method, opening exciting opportunities to perform volumetric pressure field estimation from 3D PIV measurements.

42 ENGINEERING↗

SU-F-R-32: Evaluation of MRI Acquisition Parameter Variations On Texture Feature Extraction Using ACR Phantom

Purpose: To investigate the sensitivity of classic texture features to variations of MRI acquisition parameters. Methods: This study was performed on American College of Radiology (ACR) MRI Accreditation Program Phantom. MR imaging was acquired on a GE 750 3T scanner with XRM explain gradient, employing a T1-weighted images (TR/TE=500/20ms) with the following parameters as the reference standard: number of signal average (NEX) = 1, matrix size = 256×256, flip angle = 90°, slice thickness = 5mm. The effect of the acquisition parameters on texture features with and without non-uniformity correction were investigated respectively, while all the other parameters were kept as reference standard. Protocol parameters were set as follows: (a). NEX = 0.5, 2 and 4; (b).Phase encoding steps = 128, 160 and 192; (c). Matrix size = 128×128, 192×192 and 512×512. 32 classic texture features were generated using the classic gray level run length matrix (GLRLM) and gray level co-occurrence matrix (GLCOM) from each image data set. Normalized range ((maximum-minimum)/mean) was calculated to determine variation among the scans with different protocol parameters. Results: For different NEX, 31 out of 32 texture features’ range are within 10%. For different phase encoding steps, 31 out of 32 texture features’ range are within 10%. For different acquisition matrix size without non-uniformity correction, 14 out of 32 texture features’ range are within 10%; for different acquisition matrix size with non-uniformity correction, 16 out of 32 texture features’ range are within 10%. Conclusion: Initial results indicated that those texture features that range within 10% are less sensitive to variations in T1-weighted MRI acquisition parameters. This might suggest that certain texture features might be more reliable to be used as potential biomarkers in MR quantitative image analysis.

60 APPLIED LIFE SCIENCES↗

Data Covariances from R-Matrix Analyses of Light Nuclei

After first reviewing the parametric description of light-element reactions in multichannel systems using R-matrix theory and features of the general LANL R-matrix analysis code EDA, we describe how its chi-square minimization procedure gives parameter covariances. This information is used, together with analytically calculated sensitivity derivatives, to obtain cross section covariances for all reactions included in the analysis by first-order error propagation. Examples are given of the covariances obtained for systems with few resonances ({sup 5}He) and with many resonances ({sup 13}C ). We discuss the prevalent problem of this method leading to cross section uncertainty estimates that are unreasonably small for large data sets. The answer to this problem appears to be using parameter confidence intervals in place of standard errors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scattering Properties of Large Irregular Cosmic Dust Particles at Visible Wavelengths

The effect of internal inhomogeneities and surface roughness on the scattering behavior of large cosmic dust particles is studied by comparing model simulations with laboratory measurements. The present work shows the results of an attempt to model a dust sample measured in the laboratory with simulations performed by a ray-optics model code. We consider this dust sample as a good analogue for interplanetary and interstellar dust as it shares its refractive index with known materials in these media. Several sensitivity tests have been performed for both structural cases (internal inclusions and surface roughness). Three different samples have been selected to mimic inclusion/coating inhomogeneities: two measured scattering matrices of hematite and white clay, and a simulated matrix for water ice. These three matrices are selected to cover a wide range of imaginary refractive indices. The selection of these materials also seeks to study astrophysical environments of interest such as Mars, where hematite and clays have been detected, and comets. Based on the results of the sensitivity tests shown in this work, we perform calculations for a size distribution of a silicate-type host particle model with inclusions and surface roughness to reproduce the experimental measurements of a dust sample. The model fits the measurements quite well, proving that surface roughness and internal structure play a role in the scattering pattern of irregular cosmic dust particles.

79 ASTRONOMY AND ASTROPHYSICS↗