Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor Depth”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Trace Chemical Detection Using Intercalated MXenes as a Signal Enhancing Substrate in Optical Probes

MXenes are 2D materials composed of layered transition metal nitrides or carbides. These materials are synthesized by HF exfoliation from MAX phases (Ti{sub 3}AlC{sub 2}). The 2D nanomaterial was synthesized by the removal of the 'A' element, resulting in a Mxene product (Ti{sub 3}C{sub 2}). MXenes have the general formula M{sub n+1}X{sub n}T{sub x}, where M is an early transition metal, X is Carbon and/or Nitrogen, and T accounts for surface terminated functional groups such as Fluoride, hydroxyl, and oxygen. These materials have very unique properties, similar to graphene, that allows them to be applied in a variety of trace detection techniques including surface-enhanced Raman spectroscopy (SERS). MXenes have also been demonstrated to selectively uptake uranyl ion, UO{sub 2}{sup 2+}. If this property can be combined with SERS or fluorescence detection, it may be possible to use MXenes as the basis for an alternative method to kinetic phosphorescence analysis (KPA) for trace uranyl measurements. Objectives: To confirm that MXene Nano materials are suitable substrates for SERS and sensor development by enhancing Raman signaling. To determine if certain MXene preparation methods yield materials that are more suitable for trace sensing methods. To determine uranyl uptake properties of these MXene materials and test them for analytical signals. Sample Preparation: Preparation of Ti{sub 3}C{sub 2}MXene (at FSU). MXenes were prepared by etching Al from Ti{sub 3}AlC{sub 2} (MAX phase)material. Two etching techniques yield different MXene products: LiF/HCl: Milder reaction, larger MXene flakes. HF: Harsher reaction, smaller flakes, larger layer separation. Products washed to remove etchant, vacuum filtered, and dried. Dried MXene flakes are air-stable. Film preparation for sensor testing (at SRNL): Suspend powder in diH{sub 2}O, purge with Ar, sonicate for 30 min. Centrifuge and collect supernate with suspended particles. Observed LiF-etched Mxene yielded a higher density of particles and darker collected solution. Drop-cast (4 ml) supernate onto slides and dried with Ar. For Rhodamine B (RhB) testing, drop-cast 4 ml drops onto Mxene spots and dried with Ar. Scanning Electron Microscopy conditions: 10 kV Beam energy, high vacuum; Working distance of 8 mm; beam penetration depth appx. 4 microns, beam spot size appx. 2 nanometers. Results: Detection of aluminum correlates with bright spots on image. Presence of aluminum shows that LiF/HCl etching was less thorough than HF etching. Trace Cl detection in LiF images suggests incomplete rinsing. HF has smaller feature size, more layer structure, and increased homogeneity, consistent with expectations. Macroscopic Raman spectroscopy measurements: 532 nm excitation, ∼50 mW with a ∼100 micron spot size (InPhotonics RPB probe). Kaiser Optical Holospec f/1.8 spectrometer with cooled (-60 deg.C) Andor iDus OE420 CCD. LiF 1x supernate showed good signal for trace measurements of Rhodamine B. HF and 1/4x LiF supernates showed little Mxene or Rhodamine B signal. Low deposition densities led to excess background signal from glass slides. For LiF film, response is linear with Rhodamine B concentration over range tested. Will retest with Raman microscope (∼1 micron spot size) to characterize SERS of more dilute LiF and HF etched Mxenes. Conclusions: The LiF etched material was more suitable for macroscopic SERS measurements because it was more concentrated, resulting in a thicker film than the HF etched Mxene and diluted LiF sample. However, the other materials may give greater SERS enhancements, which we hope to determine from measurements with the Raman microscope. From characterization with SEM we concluded that the HF etched Mxene is more uniform/homogenous and has smaller particle size than the LiF etched Mxene. There is still aluminum present in both samples indicating that etching wasn't complete, but the removal of the aluminum was more efficient in the HF method. Path Forward: Observe SERS with Raman microscopy, to obtain better signals for the more diluted samples and be able to compare enhancement effects for the different MXenes. Characterize uranyl sorption into MXene films and test Raman and fluorescence signals. Revisit the etching conditions to improve removal of aluminum. FSU and SRNL will continue to collaborate to create and characterize different Mxene materials and test their usefulness for sensor applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Physical and hydraulic forces experienced by fish passing through three different low-head hydropower turbines

Knowing the kinds of physical stress experienced by fish passing through hydropower turbines can help optimise technologies and improve fish passage. This paper assesses the hydraulic conditions experienced through three different low-head turbines (a very low head (VLH), Archimedes screw and horizontal Kaplan turbine), taken using an autonomous sensor. In total, 127 Sensor Fish deployments were undertaken across all three turbines, generating 82 valid datasets. Decompression was rare at the VLH and screw turbines and rarely fell more than 10kPa below atmospheric pressure. In contrast, the Kaplan was capable of generating pressures as low as 55.5kPa (~45kPa below atmospheric pressure), over shorter periods of time. More severe ratios of pressure changes could, therefore, be expected for both surface- and depth-acclimated fish at the Kaplan than at the other turbines. Strike was another possible source of fish injury (detected in 69–100% of deployments), and although strike severity was highest at the Kaplan, strike was more likely to be encountered at the screw and VLH than the Kaplan turbine. Shear occurred only near the blades of the Kaplan, and not at severe levels. The results demonstrated that low-head hydropower facilities are not without their risks for downstream migrating fish.

Boys, Craig A. (ORCID:0000000264342937)↗

Electromagnetic-Tracked Biopsy under Ultrasound Guidance: Preliminary Results

Purpose: This study was designed to evaluate the accuracy and safety of electromagnetic needle tracking for sonographically guided percutaneous liver biopsies. Methods: We performed 23 consecutive ultrasound-guided liver biopsies for liver nodules with an electromagnetic tracking of the needle. A sensor placed at the tip of a sterile stylet (18G) inserted in a coaxial guiding trocar (16G) used for biopsy was localized in real time relative to the ultrasound imaging plane, thanks to an electromagnetic transmitter and two sensors on the ultrasound probe. This allows for electronic display of the needle tip location and the future needle path overlaid on the real-time ultrasound image. Distance between needle tip position and its electronic display, number of needle punctures, number of needle pull backs for redirection, technical success (needle positioned in the target), diagnostic success (correct histopathology result), procedure time, and complication were evaluated according to lesion sizes, depth and location, operator experience, and 'in-plane' or 'out-of-plane' needle approach. Results: Electronic display was always within 2 mm from the real position of the needle tip. The technical success rate was 100%. A single needle puncture without repuncture was used in all patients. Pull backs were necessary in six patients (26%) to obtain correct needle placement. The overall diagnostic success rate was 91%. The overall true-positive, true-negative, false-negative, and failure rates of the biopsy were 100% (19/19) 100% (2/2), 0% (0/23), and 9% (2/23). The median total procedure time from the skin puncture to the needle in the target was 30 sec (from 5-60 s). Lesion depth and localizations, operator experience, in-plane or out-of-plane approach did not affect significantly the technical, diagnostic success, or procedure time. Even when the tumor size decreased, the procedure time did not increase. Conclusions: Electromagnetic-tracked biopsy is accurate to determine needle tip position and allows fast and accurate needle placement in targeted liver nodules.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluating the Feasibility of Using Strain Measured During Sinusoidal Rate Pumping Tests to Characterize an Aquifer

Pumping tests with sinusoidal variation in pumping rate have been proposed as a method for improving aquifer characterization. These tests can interrogate a larger aquifer volume than slug tests and they can be more sensitive to small variations in drawdown. Current methods of using sinusoidal variations of rate are based on measuring pressure signals from the reservoir or aquifer, which requires access to monitoring wells. An alternative approach has been developed that measures the strain in the vadose zone instead of pressure in the reservoir. An instrument has been developed at Clemson University that can measure small strains using optical fiber sensors, and we propose that it can be used to measure strain during sinusoidal pumping tests. The objective of this project is to evaluate the feasibility of measuring and interpreting the vertical strain in the vadose zone generated during a sinusoidal rate pumping tests to estimate aquifer and/or overburden properties. Pumping tests were performed at a site with a water table at 9 m and saturated saprolite from 9 to 30m depth. Sinusoidal pumping tests in the saprolite used different pumping amplitudes and periods while pressure was measured at three piezometers and vertical strain was measured in the vadose zone from 1 to 7 m depth. The delay time of the pressure increased linearly with distance, and it increased with the square root of the period, while the amplitude of the pressure decreased with distance and increased with amplitude. Vertical strain in the vadose zone varied with the same period as the pumping rate and the delay times were similar to those for pressures measured at similar radial distances. Delay times for the strain increased with an increasing propagation of the strain field. The hydraulic diffusivity was estimated using delay times for pressure and strain, and the results were compared with the values estimated from a constant-rate pumping test. The hydraulic diffusivity from the constant rate test was 0.039 m2/sec, whereas it was 0.053 (±0.05) m2/sec and 0.035 (±0.03) m2/sec from the pressure data and 0.08 (±0.022) m2/sec and 0.035 (±0.001) m2/sec from the strain data from sinusoidal tests of various periods and amplitudes. There is no statistical difference among these values. This study indicates that strain measurements in the vadose zone can be used to estimate aquifer properties during sinusoidal pumping tests.

Blais, Riley↗

Advanced monitoring of soil-vegetation co-dynamics reveals the successive controls of snowmelt on soil moisture and on plant seasonal dynamics in a mountainous watershed

Evaluating the interactions between above- and below-ground processes is important to understand and quantify how ecosystems respond differently to atmospheric forcings and/or perturbations and how this depends on their intrinsic characteristics and heterogeneity. Improving such understanding is particularly needed in snow-impacted mountainous systems where the complexity in water and carbon storage and release arises from strong heterogeneity in meteorological forcing and terrain, vegetation and soil characteristics. This study investigates spatial and temporal interactions between terrain, soil moisture, and plant seasonal dynamics at the intra- and inter-annual scale along a 160 m long mountainous, non-forested hillslope-to-floodplain system in the upper East River Watershed in the upper Colorado River Basin. To this end, repeated UAV-based multi-spectral aerial imaging, ground-based soil electrical resistivity imaging, and soil moisture sensors were used to quantify the interactions between above and below-ground compartments. Results reveal significant soil-plant co-dynamics. The spatial variation and dynamics of soil water content and electrical conductivity, driven by topographic and soil intrinsic characteristics, correspond to distinct plant types, with highest plant productivity in convergent areas. Plant productivity in heavy snow years benefited from more water infiltration as well as a shallow groundwater table depth. In comparison, low snowpack years with an early first bare-ground date, which are linked to an early increase in plant greenness, imply a short period of saturated conditions that leads to lower average and maximum greenness values during the growing season. Overall, these results emphasize the strong impact of snowpack dynamics, and terrain and subsurface characteristics on the heterogeneity in plant type and seasonal dynamics.

54 ENVIRONMENTAL SCIENCES↗

Field-amplified sample stacking and focusing in nanofluidic channels

Nanofluidic technology is gaining popularity for bioanalytical applications due to advances in both nanofabrication and design. One major obstacle in the widespread adoption of such technology for bioanalytical systems is efficient detection of samples due to the inherently low analyte concentrations present in such systems. This problem is exacerbated by the push for electronic detection, which requires an even higher sensor-local sample concentration than optical detection. This paper explores one of the most common preconcentration techniques, field-amplified sample stacking, in nanofluidic systems in efforts to alleviate this obstacle. Holding the ratio of background electrolyte concentrations constant, the parameters of channel height, strength of electric field, and concentration are varied. Although in micron scale systems, these parameters have little or no effect on the final concentration enhancement achieved, nanofluidic experiments show strong dependencies on each of these parameters. Further, nanofluidic systems demonstrate an increased concentration enhancement over what is predicted and realized in microscale counterparts. Accordingly, a depth-averaged theoretical model is developed that explains these observations and furthermore predicts a novel focusing mechanism that can explain the increased concentration enhancement achieved. Specifically, when the electric double layer is sufficient in size relative to the channel height, negatively charged analyte ions are repelled from negatively charged walls, and thus prefer to inhabit the centerline of the channels. The resulting induced pressure gradients formed due to the high and low electrical conductivity fluids in the channel force the ions to move at a slower velocity in the low-conductivity region, and a faster velocity in the high-conductivity region, leading to focusing. A simple single-channel model is capable of predicting key experimental observations, while a model that incorporates the details of the fluid inlet and outlet ports allows for more detailed comparisons between model and experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Geophysical Methods for Stratigraphic Identification

Although geophysics has been used for identifying subsurface fluid flow and contaminant spatial distributions at the Hanford Site and elsewhere, geophysics has not been generally used for identifying aquifer stratigraphy at environmentally relevant depths (> 70 m). This is because the bulk geophysical measurements of aquifer sediments cannot be directly related to sediment properties due to competing effects (e.g., porosity, pore-fluid conductivity, grain-sizes), thereby restricting the ability of conventional geophysical tools from discriminating their variation. Electrical resistivity tomography (ERT) is a method that can overcome these limitations because time-lapsed imaging, demonstrating changes in these properties over time, can be obtained from field sensors that can be left in place.

54 ENVIRONMENTAL SCIENCES↗

A Modular Accelerator Robotics Framework for AD Robotics

Accelerator tunnels, such as the ones at Fermilab, remain highly radioactive after beam shutoff due to induced radiation from the beam. This residual radiation creates a hazardous environment for manual inspection and repair of beamline components. To minimize worker radiation dose and reduce beam downtime, the AD Robotics Initiative previously built a fleet of low-cost custom mobile robots. However, the custom Python sockets server-client architecture lacked standardization, causing development delays and complicating the integration of new sensors and actuators. Here, we developed a modular system using ROS2 and Docker to standardize the teleoperation and control interfaces. This system was validated by implementing a teleoperation controller with real-time, low-latency, and high-definition video feedback. The aim of this framework is for a new feature or even a robot to be integrated into the system simply by documenting the hardware configuration. Current integration of LiDAR, Odometry, and Depth Cameras provides the foundation for Simultaneous Localization and Mapping (SLAM) tasks. Finally, future work involves integration into the accelerator control system and the attachment of a 6 degree-of-freedom robotic arm for telemanipulation.

Rayyan Khan, M. [Fermilab; Rensselaer Poly.; Unlis↗

The EGS Collab Project: Learnings from Experiment 1

The primary objective of the EGS Collab Project sponsored by DOE is to increase the understanding needed to efficiently implement enhanced geothermal systems (EGS). One goal of the EGS Collab project is to create a collaborative research environment in which to study stimulation of crystalline rock at the 10 meter scale. Key to this effort is the collection of high quality data to allow comparison to numerical coupled process models in an effort to build confidence in the codes and modeling techniques used. In response to this, the EGS Collab team has created an underground test bed at the Sanford Underground Research Facility (SURF) in Lead SD at a depth of approximately 1.5 km to examine hydraulic fracturing (Experiment 1). We are currently designing a second test bed aimed at investigating shear stimulation (Experiment 2). At the Experiment 1 location, we have characterized our host rock using laboratory testing and numerous field-based geophysical and geological techniques, and created a well-instrumented test bed to allow us to carefully monitor stimulation events and flow tests. In addition to the installed geophysical sensors, we have used tracer tests, differences in the ambient microbial communities at flow collection locations, and cold water injection to inform us about dynamic flow pathways. In Experiment 1, we have hydraulically stimulated the host rock in a number times at several locations in one well, creating new fractures that connect to existing fractures between the injection and production boreholes. We have performed long-term ambient and chilled water injection tests as an analog to EGS, and have monitored system changes resulting from these water injections through geophysical monitoring, flow and pressure measurements, tracer tests, and microbiology. Here, we summarize the tests performed, issues identified including poroelastic and thermoelastic effects, Joule-Thomson effects, restarting effects, indications of flow channeling, and the primary learnings from Experiment 1.

Enhanced Geothermal Systems, EGS Collab, stimulati↗

Modular Accelerator Robotics Framework Implementation For Accelerator Inspection

Accelerator tunnels, such as the ones at Fermilab, remain highly radioactive after beam shutoff due to induced radiation from the beam. This residual radiation creates a hazardous environment for manual inspection and repair of beamline components. To minimize worker radiation dose and reduce beam downtime, the AD Robotics Initiative previously built a fleet of low-cost custom mobile robots. However, the custom Python sockets server-client architecture lacked standardization, causing development delays and complicating the integration of new sensors and actuators. Here, we developed a modular system using ROS2 and Docker to standardize the teleoperation and control interfaces. This system was validated by implementing a teleoperation controller with real-time, low-latency, and high-definition video feedback. The aim of this framework is for a new feature or even a robot to be integrated into the system simply by documenting the hardware configuration. Current integration of LiDAR, Odometry, and Depth Cameras provides the foundation for Simultaneous Localization and Mapping (SLAM) tasks. Finally, future work involves integration into the accelerator control system and the attachment of a 6 degree-of-freedom robotic arm for telemanipulation.

Rayyan Khana, M. [Unlisted, US, IL] (ORCID:0009000↗

Laboratory Directed Research and Development Annual Report (FY 2013)

The mission of Pacific Northwest National Laboratory is to transform the world through courageous discovery and innovation. Every day, scientists and engineers at PNNL set out to fulfill the promise of that mission by advancing scientific discovery and delivering critical solutions to the challenges that face our nation and the world. The science and technology we work with, create, and improve upon inspires and enables the world to live prosperously, safely, and securely. Our investments in Laboratory Directed Research and Development are essential to our ability to advance our strategy and realize this mission. LDRD investments help us nurture science and technology capabilities while capitalizing on the breadth and depth of talent that our staff possess. This report describes how we conduct our LDRD program in compliance with DOE objectives and guidelines. We use rigorous internal and external peer review to maintain the scientific value and soundness of the research enabled by our LDRD program.

advanced sensors and instrumentation↗

Cosmic-Ray Moisture Probe on North Slope of Alaska Field Campaign Report

In September of 2014 a wide-area snow monitoring device was installed at the U.S. Department of Energy (DOE)’s Barrow, Alaska Atmospheric Radiation Measurement (ARM) Climate Research Facility site. The device is special in that it uses measurements of cosmic-ray neutrons as a proxy for snow water equivalent (SWE) depth. A unique characteristic of the technology is that it integrates over a wide area (as much as 40 ha), in contrast to conventional ground-based technologies, which essentially give point samples. Conventional point-scale technologies are problematic in the Arctic, both because extreme weather conditions are taxing on equipment, and because point measurements can fail to accurately characterize the average SWE over a larger area, even when excellent precision is obtained. The sensor installed in Barrow is, by far, the northernmost of a constellation of sites that makeup the U.S. COsmic ray Soil Moisture Observing System (COSMOS). The sensor is used for SWE measurements in winter and soil moisture measurements in summer. The ability of this type of sensor to operate in the Arctic had not been verified until now. The cosmic-ray sensor was installed on a tripod located approximately 150 m south of the ARM User Facility (Figure 1), and within boundaries of land managed by the ARM Facility. The sensor consists of both “bare” and “moderated” channels, where the moderated channel is the primary output used to calculate SWE. A QDL2100 data logger with pressure sensor was located inside of the User Facility, and a Campbell CS215 temperature and humidity sensor was attached to a rail on the upper deck of the User Facility, to enable near-real-time absolute humidity corrections to the data. The cosmic-ray sensors are connected to the data logger using an armored Cat5e cable that lies on top of the tundra. Data are retrieved hourly via Iridium satellite link.

"North Slope of Alaska, Barrow, soil moisture, cos↗

Interpreting the Strain Tensor During Injection into a Reservoir

A suite of well tests was conducted to evaluate the feasibility of measuring and interpreting the strain tensor during injection. Water was injected at 1 liter/s for a few days to a few weeks into a well completed at a depth of 530 m in the Bartlesville sandstone in the North Avant Field in Oklahoma. The strain tensor was measured using strainmeters at a depth of 30m and a distance of 220m from the well. We used a Gladwin strainmeter, a state-of-the-art geodetic strainmeter, as well as novel borehole strainmeters developed for the project. After processing, the horizontal strains were tensile and the vertical strain was compressive during injection. The radial strain was less than the circumferential strain. Strain magnitudes increased during injection and recovered afterward. The strain rate was as fast as 100 nanostrain/d at the start of injection, and decreased to 10 nanostrain/d after a few days. The normal strain signals were approximately proportional to the log of time during the first few days of injection, and the semi-log slope was 50 to 75 nanostrain. Data from the Gladwin strainmeter were essentially identical to data from a strainmeter we developed using optical fiber sensors. Tilt was measured using two tiltmeters, but the tilts were erratic compared to the normal strain and were of limited value. Strain data were analyzed using a strain type-curve method, an analytical solution to a poroelastic inhomogeneity, and a stochastic inversion method. Poroelastic simulations explain the data well. Results from the interpretation methods are consistent with each other, and with independent information characterizing the area. The hydraulic diffusivity is approximately 0.5 m2/s and the permeability is between 100 and 500 mD, according to analysis of the strain signals. This is consistent with measurements of permeability from cores, and with analyses of pressure transients. The analyses indicate that Young’s modulus of the reservoir is between 2 and 6 GPa. Strain interpretations indicate the well intersects a permeable lens with a maximum dimension of 500 to 1,000 m. An isopach map of coarse-grained sand confirms a feature roughly 1,000 m in lateral extent. The results demonstrate that the strain signal measured at shallow (30m) depth can be used to infer properties and heterogeneities in an underlying reservoir or aquifer.

Murdoch, Larry↗

Achieving ultrahigh modulus of resilience and enhanced thermal stability in ZnO x /SU-8 interpenetrating network polymer nanocomposite nanopillars

The modulus of resilience, a mechanical property that quantifies the maximum strain energy density a material can store during elastic deformation, is a crucial parameter for materials used in flexible displays, micro/nano-electro-mechanical system (M/NEMS) actuators, and ultra-sensitive pressure sensors. In this study, ZnO x /SU-8 nanocomposite nanopillars with a diameter of 300 nm, fully infiltrated with a uniformly distributed, interpenetrating amorphous ZnO x filler network, were synthesized via vapor-phase infiltration (VPI). In-situ uniaxial nano-compression tests revealed that the modulus of resilience of ZnO x /SU-8 reaches ∼ 12 MJ/m 3 , which is an ultrahigh value among all engineering materials with comparable strength. In addition, the synthesis fidelity, inorganic infiltration depth, and mechanical performance were all significantly improved compared to VPI-synthesized AlO x nanocomposites. Thermal stability, another key requirement for M/NEMS device materials operating under extreme environments, was also notably enhanced. Furthermore, partial crystallization of the amorphous ZnO x fillers during annealing contributed to an additional increase in modulus of resilience, reaching up to ∼ 13.9 MJ/m 3 . This work presents an effective fabrication strategy for producing nanostructured organic–inorganic hybrid nanocomposites with ultrahigh modulus of resilience and superior thermal stability, paving the way for their integration into next-generation flexible displays and high-performance M/NEMS devices working under harsh environments.

36 MATERIALS SCIENCE↗

BICEP2. II. Experiment and three-year data set

We report on the design and performance of the BICEP2 instrument and on its three-year data set. BICEP2 was designed to measure the polarization of the cosmic microwave background (CMB) on angular scales of 1°-5°(ℓ = 40-200), near the expected peak of the B-mode polarization signature of primordial gravitational waves from cosmic inflation. Measuring B-modes requires dramatic improvements in sensitivity combined with exquisite control of systematics. The BICEP2 telescope observed from the South Pole with a 26 cm aperture and cold, on-axis, refractive optics. BICEP2 also adopted a new detector design in which beam-defining slot antenna arrays couple to transition-edge sensor (TES) bolometers, all fabricated on a common substrate. The antenna-coupled TES detectors supported scalable fabrication and multiplexed readout that allowed BICEP2 to achieve a high detector count of 500 bolometers at 150 GHz, giving unprecedented sensitivity to B-modes at degree angular scales. After optimization of detector and readout parameters, BICEP2 achieved an instrument noise-equivalent temperature of 15.8 μK√s. The full data set reached Stokes Q and U map depths of 87.2 nK in square-degree pixels (5.'2 μK) over an effective area of 384 deg{sup 2} within a 1000 deg{sup 2} field. These are the deepest CMB polarization maps at degree angular scales to date. The power spectrum analysis presented in a companion paper has resulted in a significant detection of B-mode polarization at degree scales.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical design of PICO: a concept for a space mission to probe inflation and cosmic origins

The Probe of Inflation and Cosmic Origins (PICO) is a probe-class mission concept currently under study by NASA. PICO will probe the physics of the Big Bang and the energy scale of inflation, constrain the sum of neutrino masses, measure the growth of structures in the universe, and constrain its reionization history by making full sky maps of the cosmic microwave background with sensitivity 80 times higher than the Planck space mission. With bands at 21-799 GHz and arcmin resolution at the highest frequencies, PICO will make polarization maps of Galactic synchrotron and dust emission to observe the role of magnetic fields in Milky Way's evolution and star formation. We discuss PICO's optical system, focal plane, and give current best case noise estimates. The optical design is a two-reflector optimized open-Dragone design with a cold aperture stop. It gives a diffraction limited field of view (DLFOV) with throughput of 910 cm 2 sr at 21 GHz. The large 82 square degree DLFOV hosts 12,996 transition edge sensor bolometers distributed in 21 frequency bands and maintained at 0.1 K. We use focal plane technologies that are currently implemented on operating CMB instruments including three-color multi-chroic pixels and multiplexed readouts. To our knowledge, this is the first use of an open-Dragone design for mm-wave astrophysical observations, and the only monolithic CMB instrument to have such a broad frequency coverage. Finally, with current best case estimate polarization depth of 0.65 μKCMB-arcmin over the entire sky, PICO is the most sensitive CMB instrument designed to date.

79 ASTRONOMY AND ASTROPHYSICS↗

EGS Collab Experiment 2: Continuous Active Source Seismic Monitoring (CASSM)

The dataset contains continuous active-source seismic monitoring (CASSM) data collected during EGS Collab Experiment 2, conducted from February to September 2022 at the Sanford Underground Research Facility in Lead, South Dakota. This experiment aimed to investigate enhanced geothermal systems through high-pressure fluid injections at depths of 1200-1500 meters. The seismic monitoring system included 16 three-component piezoelectric accelerometers and 24 hydrophones installed in boreholes around the injection zones, recording signals from piezoelectric seismic sources. Data were acquired using both continuous and triggered recording systems, with sampling rates of up to 100 kHz. The raw data are organized by timestamps and stored in .dat format, with accompanying log files. Calibration certificates for selected accelerometers are provided to aid in correcting sensor responses, though users are advised to consider possible effects of enclosures and installation on sensor performance. Users are strongly advised to consult the accompanying report, which outlines the experimental setup, data acquisition, sensor specifications, and recording systems.

15 GEOTHERMAL ENERGY↗