Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solid state detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

401 records · Page 23

Quantitative Species Measurements in Microgravity Combustion Flames using Near-Infrared Diode Lasers

Understanding the physical phenomena controlling the ignition and spread of flames in microgravity has importance for space safety as well as for characterizing dynamical and chemical combustion processes which are normally masked by buoyancy and other gravity-related effects. Unfortunately, combustion is highly complicated by fluid mechanical and chemical kinetic processes, requiring the use of numerical modeling to compare with carefully designed experiments. More sophisticated diagnostic methods are needed to provide the kind of quantitative data necessary to characterize the properties of microgravity combustion as well as provide accurate feedback to improve the predictive capabilities of the models. Diode lasers are a natural choice for use under the severe conditions of low gravity experiments. Reliable, simple solid state operation at low power satisfies the operational restrictions imposed by drop towers, aircraft and space-based studies. Modulation wavelength absorption spectroscopy (WMS) provides a means to make highly sensitive and quantitative measurements of local gas concentration and, in certain cases, temperature. With near-infrared diode lasers, detection of virtually all major combustion species with extremely rapid response time is possible in an inexpensive package. Advancements in near-infrared diode laser fabrication technology and concurrent development of optical fibers for these lasers led to their use in drop towers. Since near-infrared absorption line strengths for overtone and combination vibrational transitions are weaker than the mid-infrared fundamental bands, WMS techniques are applied to increase detection sensitivity and allow measurement of the major combustion gases. In the first microgravity species measurement, Silver et al. mounted a fiber-coupled laser at the top of the NASA 2.2-sec drop tower and piped the light through a single-mode fiber to the drop rig. A fiber splitter divided the light into eight channels that directed the laser beam across a methane or propane diffusion jet flame. The light beams were recaptured by a set of gradient index lenses, coupled back into separate fiber optic lines, and transmitted back to detectors and electronics in the instrument package. In these experiments a 6-mm od fiber cable (containing the nine optical fibers) fell with the drop rig. Using separate detection and demodulation channels, spatial and temporal (up to 20 Hz) maps of water vapor and methane concentrations were obtained at differing heights in the flames. While this apparatus was useful from a demonstration standpoint, several drawbacks needed attention before useful scientific measurements could be obtained. First, eight lines of sight are somewhat insufficient for detailing the spatial profiles of the gas. Second, multiple detection channels operating in parallel are both expensive and present a challenge for accurate calibration. As a result, a newer scanning system was developed in our first contract under this program. The primary characteristic of this system is that it contains a single detection channel and achieves "continuous" spatial resolution by scanning the laser beam across the flame region, then directing this beam onto a single detector. Thus spatial measurements are converted to a temporal series of data. The true spatial resolution is limited only by the beam diameter and width of the sweep. In these experiments the beam is focused to about 1-mm diameter and scans across a region up to 4-cm wide.

Silver, Joel A.↗

The HYDICE instrument design and its application to planetary instruments

The Hyperspectral Digital Imagery Collection Experiment (HYDICE) instrument represents a significant advance in the state of the art in hyperspectral sensors. It combines a higher signal-to-noise ratio (SNR) and significantly better spatial and spectral resolution and radio metric accuracy than systems flying on aircraft today. The need for 'clean' data, i.e., data free of sampling artifacts and excessive spatial or spectral noise, is a key driver behind the difficult combination of performance requirements laid out for HYDICE. Most of these involve the sensor optics and detector. This paper presents an optimized approach to those requirements, one that comprises push broom scanning, a single, mechanically cooled focal plane, a double-pass prism spectrometer, and an easily fabricated yet wide-field telescope. Central to the approach is a detector array that covers the entire spectrum from 0.4 to 2.5 microns. Among the major benefits conferred by such a design are optical and mechanical simplicity, low polarization sensitivity, and coverage of the entire spectrum without suffering the spectral gaps caused by beam splitters. The overall system minimizes interfaces to the C-141 aircraft on which it will be flown, can be calibrated on the ground and in flight to accuracies better than those required, and is designed for simple, push-button operation. Only unprocessed data are recorded during flight. A ground data processing station provides quick-look, calibration correction, and archiving capabilities, with a throughput better than the requirements. Overall performance of the system is expected to provide the solid database required to evaluate the potential of hyperspectral imagery in a wide variety of applications. HYDICE can be regarded as a test bed for future planetary instruments. The ability to spectrally image a wide field of view over multiple spectral octaves offers obvious advantages and is expected to maximize science return for the required cost and weight.

Basedow, R.↗

A Transmission Electron Microscopy Study of a Refractory Metal Grain from a Calcium-Aluminum-Rich Inclusion in the Leoville CV3 Chondrite

Introduction: Calcium-aluminum-rich inclusions (CAIs) are an important component of chondritic meteorites. They can contain materials that are thermodynamically predicted and isotopically age dated to be among the first-formed solids in our solar system [1-5]. Observed in some CAIs are micron to sub-micron sized inclusions rich in Fe, Ni, and high-Z elements such as Pt, Os, Ir and W, in the form of refractory metal nuggets (RMNs), fremdlinges, and ‘nugget like objects’ (NLOs) [1,6]. Refractory siderophile elements such as Os, Ir and Ru are thermodynamically predicted to condense at temperatures well in excess of the major CAI phases such as melilite, perovskite, spinel and hibonite [2,7-9]. These refractory metal inclusions in CAIs can therefore serve as probes into the thermodynamic landscape of the early solar protoplanetary disk. Here we report on a refractory grain identified in a CAI of the Leoville CV3 chondrite. This work is part of an ongoing effort to gain insight into the thermochemistry of the early solar system through systematic analyses of the structure and chemistry of various components in CAIs [10-13]. Sample and Analytical Techniques: A fluffy type A CAI (Fig. 1A) was identified in a section of the Leoville, CV3 chondrite (Center for Meteorite Studies, Arizona State University collection, #821_C_3) using a JOEL-JXA 8530F electron microprobe at Arizona State University. Backscattered electron (BSE) imaging and energy-dispersive X-ray spectroscopy (EDS) were used to identify refractory metal grains in the CAI using a Thermo Fisher (formerly FEI) Helios NanoLab 660 G3 focused-ion-beam scanning-electron microscope (FIBSEM) located at the Kuiper Materials Imaging and Characterization Facility (KMICF) at the Lunar and Planetary Laboratory, University of Arizona. The FIB is equipped with an EDAX EDS system. We selected one of the larger (micron-sized) refractory metal grains, designated as ‘Spud’ (Fig. 1B) for further analysis. ‘Spud’ was extracted and thinned to electron transparency (<100 nm) using the FIB-SEM located in KMICF, following methods described by [14- 15]. The FIB section was analyzed using a 200 keV Hitachi HF5000 scanning transmission electron microscope (S/TEM) located at KMICF. The HF5000 is equipped with cold-field emission gun, 3rd-order spherical aberration corrector for STEM imaging, and an Oxford Instruments X-Max N 100 TLE energydispersive spectroscopy (EDS) system with dual 100 mm2 windowless silicon-drift detectors (Ω = 2.0 sr). Selected-area electron-diffraction (SAED) patterns were acquired to aid in determination of crystallinity and phase. Results: The mineralogy, texture, and morphology of the CAI are consistent with that of a fluffy type A (FTA) CAI [16]. BSE imaging at high magnifications revealed grains with high contrast, indicative of compositions rich in elements of higher atomic number relative to surrounding material. These high-Z grains have sizes that range from ∼250 nm to 4 µm. EDS analyses confirm that the bright grains are metal-rich inclusions. A minor fraction of the grains are composed of only Fe and Ni, but the majority (∼60%) of the identified inclusions also contained various refractory siderophiles including Os, Ru, Zr, Ir and Mo. EDS analysis on the FIB-SEM of Spud shows that it contains Fe, Ni, Mo and Ru. High-angle annular dark-field (HAAFD) imaging and EDS mapping in the TEM (Fig. 2) show that Spud occurs in melilite (Ca1.9Al1.99Si1.06O7). Spud contains a subhedral to anhedral morphology and is compositionally heterogenous (polyphasic, Fig. 2). Local spatial correlation occurs among Fe, Ni, and Pt, and also among Os, Ru, and Mo. SAED patterns show that the Fe-Ni-Pt, Fe-Os-Mo-Ru and Fe-Pt regions are crystalline. Discussion: CAIs can contain various types of inclusions rich in Fe, Ni and refractory siderophiles such as Os, Ru, W and Pt [1]. RMNs are micron-sized, single phase alloy grains and can contain Os, Ir, Ru and Rh [1,7,17]. NLOs are also micron-sized inclusions, but contain two phases, a refractory metal, and an oxide [6]. Fremdlinge are the largest of such inclusions (tens of microns in size) and are complex aggregates of Fe-Ni alloy, silicates, oxides, and sulfides [1,17]. While the size of Spud matches previous descriptions of RMNs and NLOs, Spud is neither a single-phase alloy like RMNs, nor does it contain one metal phase and one oxide like NLOs. Spud does not match the above described categories of refractory metal inclusions. The presence of refractory siderophiles such as Mo, Os, Ru, and Pt suggests a high-temperature origin. Thermodynamic modelling by [7] indicates condensation temperatures of 1917 K, 1693 K, 1613 K and 1415 K for Os, Mo, Ru and Pt respectively. These models also show that following the initial condensation of a refractory metal, alloying of solutes such as Fe, Ni and W, occurs in levels proportional to their partial pressures in the surrounding gas. Such alloying occurs at temperatures above the condensation temperatures of common CAI phases such as melilite (1529 K), perovskite (1441 K), spinel (197 K) and forsterite (1354 K) [2]. The polyphasic nature of Spud could be the result of such high-temperature alloying, possibly shortly after the condensation of Mo and Ru at 1693 K and 1613 K respectively. That Spud occurs as an inclusion is consistent with it having formed prior to and at temperature above that of its host melilite in this FTA CAI, which is qualitatively consistent with such prior thermodynamic modeling. Further, the polyphasic nature of Spud is similar to refractory grains from a FTA CAI in the Northwest Africa (NWA) 8323, CV3 chondrite [11-13]. These data suggest that such refractory metal grains could have been widespread in the inner and early solar protoplanetary disk and represent some of the earliest formed solids to have condensed. Acknowledgments: Research and instrumentation supported by NASA grants #NNX12AL47G, #NNX15AJ22G and #80NSSC19K0509, and NSF grants #1531243 and #0619599. Fig 2. STEM data on ‘Spud’. HAADF Image (Top) False-color EDS Maps (Bottom) References: [1] MacPherson G. J. (2014) T. of Geochem. Vol I: Met. And Cosmochem. Processes, 139-179. [2] Lodders K. (2003) ApJ, 591, 1220-1247. [3] Ebel D. S. (2006) Met. & the Early S. Sys. II., 253- 277. [4] Amelin Y. (2002) Science, 297, 1678-1683. [5] Connelly J.N. et.al. (2012) Science, 338, 651-655. [6] Schwander D. et al. (2015) GCA, 18, 70-87. [7] Palme H. and Wlotzka F. (1976) EPSL, 33, 45-60. [8] Berg T. et al. (2009) ApJ, 702, 172-176. [9] Liffman K. et al. (2021) Icarus, 221, 89-105. [10] Zega T.J. et al. (2021) PSJ, 2, 115. [11] Ramprasad T. et al. (2020) LPSC LI, Abstract #2472. [12] Ramprasad T. et al. (2021) Microscopy & Microanalysis, S1, 2792-2794. [13] Ramprasad T. et al. (2021) 84th MetSoc, Abstract #6123. [14] Zega T.J. et al. (2007) MAPS, 42, 1373-1386. [15] Ramprasad T. et al. (2022) MAPS, in revision. [16] Grossman L. (1975), GCA, 39, 433-454. [17] El Goresy A. et al. (1978) LPSC IX, Abstract#1100

T. Ramprasad↗

Growth experiment of narrow band-gap semiconductor PbSnTe single crystals in space (M-1)

An experiment on crystal growth of Pb(1-x)Sn(x)Te in microgravity is planned. This material is an alloy of the compound semiconductors PbTe and SnTe. It is a promising material for infrared diode lasers and detectors in the wavelength region between 6 and 30 micron. Since the electrical properties of Pb(1-x)Sn(x)Te depend greatly on the Pb/Sn ratio and crystalline defects as well as impurity concentration, homogeneous, defect-free, high-quality crystals are anticipated. Although many growth methods, such as the pulling method, the Bridgman method, the vapor growth method, etc., have been applied to the growth of Pb(1-x)Sn(x)Te, large, homogeneous, low-defect-density crystals have not yet been grown on Earth. The unsuccessful results were caused by buoyancy-driven convection in the fluids induced by the specific gravity difference between heated and cooled fluids on Earth. A crystal is grown by cooling the melt from one end of the ampoule. In crystal growth from the melt, about 30 percent of the SnTe in the melt is rejected at the solid-liquid interface during solidification. On Earth, the rejected SnTe is completely mixed with the remaining melt by convection in the melt. Therefore, SnTe concentration in the melt, and accordingly in the crystal, increases as the crystal grows. In the microgravity environment, buoyancy-driven convection is suppressed because the specific gravity difference is negligible. In that case, the rejected SnTe remains at the solid-liquid interface and its concentration increases only at the interface. If the growth rate is higher than the PbTe-SnTe interdiffusion rate, the amount of SnTe which diffuses from the interface into the melt increases as SnTe piles up at the interface, and finally it balances the amount of rejected SnTe during solidification, resulting in steady-state SnTe transportation at the interface. By using this principle, compositionally homogeneous crystals can be grown. Furthermore, low-defect-density crystals will be grown in microgravity, because convection causes crystalline defects by mising hot and cold fluids and generating temperature fluctuations in them.

Yamada, Tomoaki↗

In Situ Multi-Species (O2, N2, Fuel, Other) Fiber Optic Sensor for Fuel Tank Ullage

A rugged and compact fiber optic sensor system for in situ real-time measurement of nitrogen (N2), oxygen (O2), hydrocarbon (HC) fuel vapors, and other gases has been developed over the past several years at Glenn Research Center. The intrinsically-safe, solid-state fiber optic sensor system provides a 1% precision measurement (by volume) of multiple gases in a 5-sec time window. The sensor has no consumable parts to wear out and requires less than 25 W of electrical power to operate. The sensor head is rugged and compact and is ideal for use in harsh environments such as inside an aircraft fuel tank, or as a feedback sensor in the vent-box of an on-board inert gas generation system (OBIGGS). Multiple sensor heads can be monitored with a single optical detection unit for a cost-effective multi-point sensor system. The present sensor technology is unique in its ability to measure N2 concentration directly, and in its ability to differentiate different types of HC fuels. The present sensor system provides value-added aircraft safety information by simultaneously and directly measuring the nitrogen-oxygen-fuel triplet, which provides the following advantages: (1) information regarding the extent of inerting by N2, (2) information regarding the chemical equivalence ratio, (3) information regarding the composition of the aircraft fuel, and (4) by providing a self-consistent calibration by utilizing a singular sensor for all species. Using the extra information made available by this sensor permits the ignitability of a fuel-oxidizer mixture to be more accurately characterized, which may permit a reduction in the amount of inerting required on a real-time basis, and yet still maintain a fire-safe fuel tank. This translates to an increase in fuel tank fire-safety through a better understanding of the physics of fuel ignition, and at the same time, a reduction in compressed bleed air usage and concomitant aircraft operational costs over the long-run. The present fiber optic sensor can also be used as a false-alarm-free engine/hidden/cargo space fire detector (by measuring increased CO2 and CO, and decreased O2), a multi-point in situ measurement and certification system for halogenated-compound fire protection systems, and for the testing and certification of other aircraft safety sensor systems. The technology (LEW-17826-1) developed in the present sensor system is patent pending.

Nguyen, Quang-Viet↗