Search NASA⌕ Search

SEARCH · Search NASA

Results for “Space Environment Simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Strangeness-changing rates and hyperonic bulk viscosity in neutron star mergers

In this paper we present a computation of the rates of strangeness-changing processes and the resultant bulk viscosity in matter at the densities and temperatures typical of neutron star mergers. To deal with the high temperature in this environment we go beyond the Fermi surface approximation in our rate calculations and numerically evaluate the full phase space integral. Here, we include processes where quarks move between baryons via meson exchange: these have generally been omitted in previous analyses but provide the dominant contribution to the rates of strangeness-changing processes and the bulk viscosity. The calculation of these rates is an essential step towards any calculation of dissipation mechanisms in hyperonic matter in mergers. As one application, we calculate the dissipation times for density oscillations at the frequencies seen in merger simulations. We find that hyperon bulk viscosity for temperatures in the MeV regime can probably be neglected in this context, but becomes highly relevant for keV-range temperatures.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scoping Thermal Response Calculations of RNS Waste During Transport to and Disposal at the WIPP

Sandia National Laboratories (SNL) was contracted by the United States Department of Energy Environmental Management (DOE-EM), Los Alamos Field Office to perform mechanical and thermal scoping calculations as part of a study seeking to understand the ignitability risk of the Remediated Nitrate Salts (RNS) waste drums during transportation from the Waste Control Specialists (WCS) facility to Waste Isolation Pilot Plant (WIPP) and permanent disposal of the waste at WIPP. The scoping thermal simulations described in this report pertain to thermal calculations performed with a packaging system consisting of one Standard Waste Box (SWB) loaded with drums placed inside a Standard Large Box 2 (SLB2). During transportation, the SLB2 is inside Transuranic Package Transporter Model III (TRUPACT-III), which provides the third layer of the packaging. Once at the WIPP, it is assumed the SLB2 is extracted from the TRUPACT-III and maintained above ground, and then subsequently placed underground for permanent disposal. In these proposed configurations, the space between the SLB2 and the SWB is always filled by a layer of insulation consisting of air-filled glass microbubbles except for the bottom which rests directly on the SLB2. The thermal scoping calculations described in this report specifically address whether the introduction of external heat inputs, combined with the contributions from the internally generated radiolytic decay heat and chemical reactions, lead to an unstable thermal state during the time of its movement and placement in the permanent disposal location. The external heat inputs are of two forms: 1) ambient thermal irradiation (e.g., solar and ambient storage/disposal temperatures) and 2) accident-induced fire. Three scoping calculation scenarios were derived as representative, conservative scenarios: 1A) TRUPACT-III transient transportation, 1B) SLB2 48-hour outdoor storage with solar radiation, and 2) fully-engulfing fire during SLB2 handling or emplacement following a steady-state analysis in a 38 °C environment. All the simulated scenarios are conservative relative to the operational conditions expected for handling the waste package during transportation and placement in the WIPP underground disposal unit. The predictions obtained from simulating the three exposure scenarios revealed that adding the SLB2 and the air-filled glass microbubbles to the transport and storage/disposal configurations provides additional thermal protection of the drums beyond what the SWB provides alone, both during long-term above ground insolation and underground during a fire accident. Under the current transportation/storage/disposal concepts, the degree of protection provided by the packaging concept is sufficient to prevent the waste from being ignitable. The simulation results demonstrate that there is adequate margin to safely transport and place the RNS waste from WCS to the WIPP under the current operational concept.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Energy-Efficient and Comfortable Buildings through Multivariate Integrated Control (ECoMIC)

This project aims to develop an integrated control solution for enhanced energy efficiency and user comfort in commercial buildings. The developed technology is a zone-based control framework that minimizes energy usage while maintaining occupants’ visual and thermal comfort through control of electric lights, motorized venetian blinds and thermostats. The control framework is designed following a modular, scalable and flexible architecture to facilitate easy integration with exiting building management systems. The control framework contains two key algorithms: 1) the lighting load balancing algorithm and 2) the thermostat control algorithm. The lighting load balancing algorithm adopts a model-based closed-loop control approach to determine the optimal electric light and venetian blind settings. It is formulated into an optimization problem with minimizing lighting-related energy consumptions as the objective and delivering adequate task light and preventing daylight glare as the constraints. The thermostat control algorithm is based on a well-established thermal comfort model and formulated as a root-finding problem to dynamically determine the optimal thermostat setpoint for both energy savings and improved thermal comfort. To address building-wide scalability, a system architecture was developed for the zone-based control technology. Three levels of services are defined in the architecture: external services, facility level services and zone level services. The zone-level service includes the control algorithms described above as well as the corresponding interfaces, profiles, sensors and actuators to realize the zone controller. The facility level services connect to the zones through a backbone network, handle supervisory level information and controls, and thus facilitate building-wide scalability. The external services provide communication capability to entities outside of the building for grid interaction and remote access. Various aspects of the developed control technology were evaluated and verified through both simulations and testbed implementations. Simulations coupling a DOE medium office reference building in EnergyPlus building simulation software and a prototype controller in Matlab were performed. During summer time in a mixed-humid climate zone, the simulations revealed reductions of 27% and 42% in electric lighting load and cooling load, respectively, when compared to an advanced base case with daylight dimming and blinds automatically tilted to block direct sun. Two single-room testbeds were established. The testbed at Philips Lighting business building (Rosemont, IL) was designed for quantifying energy performance of integrated controls. This particular implementation achieved 40% and 79% savings on lighting and HVAC energy, respectively, compared to a relatively simple base case operated on predefined schedules. While the resulting energy savings was very encouraging, it should be noted that there may be several caveats associated with it. 1) The test was run during late spring and early summer, and the savings numbers might not be directly used to extrapolate the annual energy savings. 2) Due to the needs for separate control and metering of the small-scale demonstrator within a large building, the HVAC system, hence the corresponding savings, did not represent a typical energy code-compliant design. 3) The light level in the control case was regulated at a particular setpoint, which was lower than then the full-on light level in the base case, and the savings resulted from tuning down the light level to the setpoint was not attributable to the contribution of the developed technology. The testbed at the Lawrence Berkeley National Laboratory (Berkeley, CA) specifically focused on glare control integration, and has demonstrated the feasibility and capability of the glare detection and prevention technique. While the short one-month test in this testbed provided a functional indication of the developed technology, and it would require at least a full solstice-to-solstice cycle to ruinously quantify the performance, which was not possible within the project timeframe. There are certain limitations inherited from the operational assumptions, which could potentially affect the effectiveness and applicability of the developed control technologies. The system takes a typical ceiling-mounting approach for the photosensor locations, and therefore, the control performance relies on proper commissioning or the built-in intelligence of the photosensor for pertinent task light level estimations. For spaces where daylight penetration diminishes significantly deeper into the zone, certain modification to the control algorithms is required to accommodate multiple lighting control subzones and the corresponding sensors for providing a more uniform light level across the entire zone. Integrated control of visual and thermal comfort requires the lighting control zone and thermal control zone to coincide with each other. In other words, the area illuminated by a lighting circuit needs to be the same area served by the thermostat. Thus, the original zoning will potentially constrain the applicability of this technology in retrofitting projects. This project demonstrated the technical feasibility of a zone-based integrated control technology. From the simulation results and testbed implementations, up to 60% lighting energy savings in daylit areas relative to a “no-controls” case can easily be achieved. A 20% reduction of whole building energy consumption is also attainable. In the aspect of occupant comfort, the testbed demonstrated the ability to maintain specified light level on the workplane while promptly mitigate daylight glare 90% of the time. The control system also managed to maintain the thermal environment at a comfortable level 90% of the time. The aspect of system scalability was guaranteed by the system architecture design, based on which the testbeds were instantiated. Analysis on the aspect of economic benefit has yielded an about 6-year payback time for a medium-sized building, including the installation of all hardware and software, such as motorized blinds and LED luminaires. The payback time can be significantly reduced if part of the hardware is already in place for retrofitting projects. It needs to be noted that since the payback analysis was partly based on the testbed performance results, it is constrained by the caveats associated with the testbed implementations. The main uncertainty lies in the contribution from the space conditioning energy savings as it was non-trivial to realistically configure a room-size HVAC system for directly extrapolating whole-building HVAC energy savings. It is recommended to further evaluate the developed technology at a larger scale, where the lighting and HVAC energy consumption can be realistically measured at the building level, to more rigorously quantify the performance potentials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulating large one-dimensional neutral-atom quantum systems

While abstract models of quantum computation assume a closed system of two-level states, practical quantum devices inevitably couple to the environment in some way, creating sources of noise. Understanding the tolerance to noise of specific quantum algorithms run on specific devices is important for determining the feasibility of quantum computing in the current noisy intermediate-scale quantum era. Of particular interest is understanding the noise sensitivity of these devices as more qubits are added to the system. Classical simulations are a useful tool to understand the effects of this noise, but direct classical simulations of open quantum systems are burdened by an exponentially growing cost in the number of qubits and a large local Hilbert space dimension. For onedimensional, shallow circuits, using tensor networks can replace this exponential cost with a linear one and simulate far wider systems than what would normally be available. In this paper, we describe a tensor network simulation of a neutral atom quantum system under the presence of noise, while introducing a purity-preserving truncation technique that compromises between the simplicity of the matrix product state and the positivity of the matrix product density operator. We apply this simulation to a near-optimized iteration of the quantum approximate optimization algorithm on a transverse field Ising model in order to investigate the influence of large system sizes on the performance of the algorithm. We find that while circuits with a large number of qubits fail more often under noise that depletes the qubit population, their outputs on a successful measurement are just as robust under Rydberg atom dissipation or qubit dephasing as smaller systems. However, such circuits might not perform as well under coherent multiqubit errors such as Rydberg atom crosstalk. We also find that the optimized parameters are especially robust to noise, suggesting that a noisier quantum system can be used to find the optimal parameters before switching to a cleaner system for measurements of observables.

Allen, James↗

TEAMER: Numerical Modeling and Optimization of the iProTech Pitching Inertial Pump (PIP) Wave Energy Converter (WEC)

This project focused on developing an automated workflow to evaluate and optimize the iProTech Pitching Inertial Pump (PIP) wave energy converter (WEC) using open-source Python packages and the MATLAB/Simulink tool, WEC-Sim. The process involved parameterizing key design variables, running time-domain simulations, and performing sensitivity analyses to determine their impact on power output. The workflow, designed for the PIP device, is generalized and can be extended to optimize other WECs that can be simulated in WEC-Sim. This work establishes a foundation for future time-domain-based WEC design optimizations. Included in this submission are all figures from the final report and the model inputs required to generate them. This includes Python scripts with inputs that produce the meshes, boundary element method (BEM) models, hydrodynamic coefficients, and the WEC-Sim models used for time-domain analyses. Although data for every single run is not included to save space, all of it can be reproduced using the provided models. Detailed instructions for setting up the environment and running the codes are also included.

16 TIDAL AND WAVE POWER↗

Do Impulsive Solar-Energetic-Electron (SEE) Events Drive High-Voltage Charging Events on the Nightside of the Moon?

When the Earth’s moon is in the supersonic solar wind, the darkside of the Moon and the lunar plasma wake can be very dangerous charging environments. In the absence of photoelectron emission (dark) and in the absence of cool plasma (wake), the emission or collection of charge to reduce electrical potentials is difficult. Unique extreme charging events may occur during impulsive solar-energetic-electron (SEE) events when the lunar wake is dominated by relativistic electrons, with the potential to charge and differentially charge objects on and above the lunar surface to very-high negative electrical potentials. In this report the geometry of the magnetic connections from the Sun to the lunar nightside are explored; these magnetic connections are the pathways for SEEs from the Sun. Rudimentary charging calculations for objects in the relativistic-electron environment of the lunar wake are performed. To enable these charging calculations, secondary-electron yields for impacts by relativistic electrons are derived. Needed lunar electrical-grounding precautions for SEE events are discussed. Calls are made 1) for future dynamic simulations of the plasma wake in the presence of time-varying SEE-event relativistic electrons and time-varying solar-wind magnetic-field orientations and 2) for future charging calculations in the relativistic-electron wake environment and on the darkside lunar surface.

79 ASTRONOMY AND ASTROPHYSICS↗

Graybox and adaptative dynamic neural network identification models to infer the steady state efficiency of solar thermal collectors starting from the transient condition

This paper deals with the development of methods for non steady state test of solar thermal collectors. Our goal is to infer performances in steady-state conditions in terms of the efficiency curve when measures in transient conditions are the only ones available. We take into consideration the method of identification of a system in dynamic conditions by applying a Graybox Identification Model and a Dynamic Adaptative Linear Neural Network (ALNN) model. The study targets the solar collector with evacuated pipes, such as Dewar pipes. The mathematical description that supervises the functioning of the solar collector in transient conditions is developed using the equation of the energy balance, with the aim of determining the order and architecture of the two models. The input and output vectors of the two models are constructed, considering the measures of 4 days of solar radiation, flow mass, environment and heat-transfer fluid temperature in the inlet and outlet from the thermal solar collector. The efficiency curves derived from the two models are detected in correspondence to the test and validation points. The two synthetic simulated efficiency curves are compared with the actual efficiency curve certified by the Swiss Institute Solartechnik Puffung Forschung which tested the solar collector performance in steady-state conditions according to the UNI-EN 12975 standard. An acquisition set of measurements of only 4 days in the transient condition was enough to trace through a Graybox State Space Model the efficiency curve of the tested solar thermal collector, with a relative error of synthetic values with respect to efficiency certified by SPF, lower than 0.5%, while with the ALNN model the error is lower than 2.2% with respect to certified one. (author)

14 SOLAR ENERGY↗

Persistent Supercooled Drizzle at Temperatures Below -25 °C Observed at McMurdo Station, Antarctica

The rarity of reports in the literature of brief and spatially limited observations of drizzle at temperatures below -20 degrees C suggest that riming and other temperature-dependent cloud microphysical processes such as heterogeneous ice nucleation and ice crystal depositional growth prevent drizzle persistence in cold environments. In this study, we report on a persistent drizzle event observed by ground-based remote sensing measurements at McMurdo Station, Antarctica. The temperatures in the drizzle-producing cloud were below -25 degrees C and the drizzle persisted for a period exceeding 7.5 hr. Using ground-based, satellite, and reanalysis data, we conclude that drizzle was likely present in parts of a widespread cloud field, which stretched more than similar to 1,000 km along the Ross Ice Shelf coast. Parameter space sensitivity tests using two-moment bulk microphysics in large eddy simulations constrained by the observations suggest that activated ice freezing nuclei and accumulation-mode aerosol number concentrations aloft during this persistent drizzle period were likely on the order of 0.2 L-1 and 20 cm -3 , respectively. In such constrained simulations, the drizzle moisture flux through cloud base exceeds that of ice. The simulations also indicate that drizzle can lead to the formation of multiple peaks in cloud water content profiles. This study suggests that persistent drizzle at these low temperatures may be common at the low aerosol concentrations typical of the Antarctic and Southern Ocean atmospheres.

54 ENVIRONMENTAL SCIENCES↗

Comparative Performance of Low Global Warming Potential (GWP) Refrigerants as Replacement for R-410A in a Regular 2-Speed Heat Pump for Sustainable Cooling

Heat pumps are currently being developed to reduce the energy footprint for residential and commercial building space conditioning and water heating loads in cold climates. To mitigate the nocuous impact of greenhouse gas emissions on the environment, and to create a carbon-neutral building stock, alternate lower-GWP refrigerants must also replace the predominant use of R-410A, without re-engineering the mechanical hardware. In this paper, we analyze the performance of lower-GWP alternative refrigerants (R-32, R-452B, R-454B, and R-466A) relative to the conventional R-410A and draw conclusions on the relative performances to meet cooling loads. The simulations are accomplished using the heat pump design model, a well-known, public-domain design tool with a free web interface and downloadable desktop version to support public use and the HVAC R&D community. The contributions contain detailed, hardware-based heat exchanger and system analyses to provide a comprehensive assessment. The results of the simulation are scrutinized from the first (capacity and energy efficiency) and second laws (exergy analysis) to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate lower-GWP refrigerants to replace R-410A using the same hardware. The results have practical value in engineering heat pumps in an economy that is compelled to alter by the consequences and uncertainties of climate change, to reduce its anthropogenic carbon footprint.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A New Framework for Interstellar Medium Emission Line Models: Connecting Multiscale Simulations across Cosmological Volumes

The James Webb Space Telescope (JWST) and Atacama Large Millimeter/submillimeter Array have detected emission lines from the ionized interstellar medium (ISM) in some of the first galaxies at z ≳ 6. These measurements present an opportunity to better understand galaxy assembly histories and may allow important tests of state-of-the-art galaxy formation simulations. It is challenging, however, to model these lines in their proper cosmological context. In order to meet this challenge, we introduce a novel subgrid line emission modeling framework. The framework uses the high-z zoom-in simulation suite from the Feedback in Realistic Environments (FIRE) collaboration. The line emission signals from H II regions within each simulated FIRE galaxy are modeled using the semianalytic HIIL INES code. A machine learning approach is then used to determine the conditional probability distribution for the line luminosity to stellar-mass ratio from the H II regions around each simulated stellar particle. This conditional probability distribution can then be applied to predict the line luminosities around stellar particles in lower-resolution, yet larger volume cosmological simulations. As an example, we apply this approach to the IllustrisTNG simulations at z = 6. The resulting predictions for the [O II ], [O III ], and Balmer line luminosities as a function of star formation rate agree well with current observations. Our predictions differ, however, from related works in the literature, which lack detailed subgrid ISM models. This highlights the importance of our multiscale simulation modeling framework. Finally, we provide forecasts for future line luminosity function measurements from the JWST and quantify the cosmic variance in such surveys.

(ISM:) H II regions↗

A Study of Particle Beam Spin Dynamics for High Precision Experiments

In the search for physics beyond the Standard Model, high precision experiments to measure fundamental properties of particles are an important frontier. One group of such measurements involves magnetic dipole moment (MDM) values as well as searching for an electric dipole moment (EDM), both of which could provide insights about how particles interact with their environment at the quantum level and if there are undiscovered new particles. For these types of high precision experiments, minimizing statistical uncertainties in the measurements plays a critical role. \\ \indent This work leverages computer simulations to quantify the effects of statistical uncertainty for experiments investigating spin dynamics. In it, analysis of beam properties and lattice design effects on the polarization of the beam is performed. As a case study, the beam lines that will provide polarized muon beams to the Fermilab Muon \emph{g}-2 experiment are analyzed to determine the effects of correlations between the phase space variables and the overall polarization of the muon beam.

43 PARTICLE ACCELERATORS↗

Neural MUSE Analysis

Researchers at Oak Ridge National Laboratory (ORNL) created data as part of the MUSE (Multi-Agency Urban Search Experiment Detector and Algorithm Test Bed) project simulating illicit nuclear materials located in various buildings along a road. In the simulation, a truck containing a radiation detector drives down the road gathering listmode data (counting the and energy of incident gamma radiation). Building materials, source shielding, driving speed, truck direction, truck location on the road, source type, and source placement are all varied between runs of the data set. This data was created using deterministic neutron transport and Monte Carlo methods through a combination of SCALE, MAVRIC, MCNP, and GADRAS. As part of a follow-on NA-22 project, two Kaggle competitions were created to determine the best algorithms for finding and identifying gamma sources in this simulated urban environment. The winning algorithm was neural network-based and had a test accuracy of 76.4% accuracy for source identification. This work seeks to build upon this work and improve the results through the application of novel machine learning techniques. As a first step, the data was classified by a simple Convolutional Neural Network (CNN) To accomplish this, the data was first preprocessed into “waterfall plots.” These plots are composed of energy vs count plots that are stacked vertically to show progression in time. The horizontal axis indicating the particle energy incorporated user defined bin spacing with options for in linear-, logarithmic-, square root-, and user-spaced bins. The z or color dimension showed the number of counts corresponding the energy-time combination. This data was then used to generate more data, by generating a local estimate of the mean of the distribution for a bin and then randomly re-sampling that bin from a Poisson distribution. Once all of this data was generated, it was fed into a well-known CNN architecture, ResNet50. The output layer of this model was removed and replaced with layers corresponding to the shape desired isotope outputs. The provided training data was used to train the classifier and the remaining testing data was used to evaluate the model. Results are soon to be forthcoming.

61 RADIATION PROTECTION AND DOSIMETRY↗

Integrating NASA Earth Science Capabilities into the Interagency Modeling and Atmospheric Assessment Center for Improvements in Atmospheric Transport and Dispersion Modeling

This report describes the development of algorithms to derive accurate surface roughness and displacement height values from NASA satellite data for both urban and vegetation environments and to evaluate the potential benefit of improved surface data characterization on atmospheric transport and dispersion modeling. One of the key factors limiting the accuracy of near-surface wind profile modeling and dispersion simulations is the lack of location-specific and seasonally-dependent surface characteristic values. Currently, land use category look-up tables are commonly used to provide grid-cell estimates of surface characteristics values, even though surface roughness values can vary significantly within the same land-use category. This report documents: i) the derivation of surface characteristic values by Goddard Space Flight Center (GSFC) and Stennis Space Center (SSC) from NASA satellite multispectral imagery, ii) their incorporation into atmospheric meteorological and transport models, and iii) the results of a dispersion modeling study for Oklahoma City and the surrounding region to evaluate the impact of GSFC/SSC roughness on National Atmospheric Release Advisory Center (NARAC) / Interagency Modeling and Atmospheric Assessment Center (IMAAC) emergency response dispersion predictions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhanced Performance Fast Reactors with Engineered Passive Safety Systems

This report summarizes the work and results of NEUP Project #15-8251, "Enhanced Performance Fast Reactors with Engineered Passive Safety System," performed from 2015-2018 at UC Berkeley and Argonne National Laboratory. This project concerns the incorporation of a novel engineered passive safety system, called the Autonomous Reactivity Control (ARC) system, into Sodium-cooled Fast Reactors (SFRs) to improve their transient and economic performance. The first part of this project consisted of fleshing out the basic principles and the manufacturing process for an SFR fuel assembly with the ARC system installed, with the details provided in high-quality, step-by-step CAD drawings. Once the detailed design is laid out, high-fidelity simulations were performed to optimize the dimensions of important ARC system components and to quantify the standalone time-response of ARC systems in a typical SFR environment. These high-fidelity simulations were used to create reduced-order models of ARC system response which could be incorporated into the SAS4A/SASSYS-1 whole-core transient models. In order to accurately account for the time-response of ARC systems in whole-core transient simulations, modifications were made to the SAS4A/SASSYS-1 transient code. These new capabilities were tested and incorporated into the production version of the code, and have been used extensively in this analysis. Before performing whole-core transient calculations, the two reference cores selected for this study to cover a wide design space were simulated and characterized. The two reference cores, (1) a medium-sized oxide-fueled Advanced Burner Reactor and (2) a large metal-fueled Breed-and-Burn core, challenge conventional means of achieving passive safety. Because the two cores vary substantially, simulating the ARC system in both allows for conclusions to be drawn about the applicability of ARC systems in different SFRs. Once both cores were fully characterized, transient calculations were performed to understand the complicated interplay between the ARC system and other inherent reactivity feedback mechanisms. By performing parametric studies of the transient behavior, ARC system designs that best improve transient performance in each core were identified. Once transient improvements were established, the transient calculations were extended to improve reactor economics through design modifications. Upon establishing the potential benefits of ARC system inclusion, the study examines the negative neutronic implications of incorporating ARC systems into the reference cores. The study concludes by discussing a number of knowledge gaps that exist which may have important implications for ARC system implementation. Ultimately, the results of this project indicate that ARC systems may provide an effective means to improve transient performance in certain types of systems. The transient simulations in the oxide Advanced Burner Reactor showed that significant margin to coolant boiling and fuel melting could be gained through the use of a properly designed ARC system, thus improving inherent safety. While oscillatory behavior was induced in the transient response for certain combinations of ARC system parameters, the oscillation-free design space that can be effectively used to improve performance was found to be large, and the additional margin was demonstrated to allow economical improvements to the core design. Conversely, difficulties were encountered in the Breed-and-Burn core due to fundamental aspects of the core design. The combination of a particularly strong positive coolant void feedback and the use of metallic fuel allowed for diverging oscillations to manifest in response to certain transient initiators, and in the end it was found that the current ARC system design could not simultaneously enable passive safety in all transients examined. In order for complete passive safety to be achieved, a mechanism for slowing the reverse actuation of ARC systems is necessary. Regardless, the standard ARC system was able to improve the performance of two out of the three examined transients by increasing the margin to boiling in Loss of Heat Sink transients and avoiding boiling in Transient Overpower accidents. Additionally, no significant barriers to implementation were found, although the issue of tritium production should be closely monitored in any core incorporating ARC systems. Still, a number of technology gaps exist, and these are discussed at the conclusion of the report to recommend directions for future work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparison of two-fluid and gyrokinetic models for kinetic Alfvén waves in solar and space plasmas

An analytical comparative study of a two-fluid and a gyrokinetic model of kinetic Alfvén waves (KAWs) is presented for various solar and space plasma environments. Based on the linear KAW dispersion relation for gyrokinetics (Howes et al. 2006), the wave group velocity and electromagnetic polarizations are obtained analytically. Then the gyrokinetic wave properties are compared with those of the two-fluid model. The results show that both models agree well with each other not only in the long wavelength regime (>> the ion gyroradius ρ {sub i}) for all cases considered, but also in wavelengths ∼ρ {sub i} and <<ρ {sub i} (still much larger than the electron gyroscale) for a moderate or low (≲ 1) and a high (>>1) ion/electron temperature ratio T {sub 0i}/T {sub 0e}, respectively. However, the fluid model calculations deviate strongly from the gyrokinetic model at scales <ρ {sub i} for a relatively low T {sub 0i}/T {sub 0e} due to the electron gyroradius effect. Meanwhile, the plasma β {sub i} can make the gyrokinetic dispersion relation of KAWs become complex and sometimes have an oscillation-like structure. With the inherent simplicity of the fluid theory, these results may improve our understanding of the applicability of the two-fluid model, and may have important implications for computer simulation studies of KAWs in the solar and space plasma surroundings.

79 ASTRONOMY AND ASTROPHYSICS↗

Real-Space Pseudopotential Method for the Calculation of Third-Row Elements X-ray Photoelectron Spectroscopic Signatures

X-ray photoelectron spectroscopy (XPS) is a powerful characterization technique that unveils subtle chemical environment differences via core– electron binding energy (CEBE) analysis. We extend the development of realspace pseudopotential methods to calculating 1s, 2s, and 2p 3/2 CEBEs of third-row elements (S, P, and Si) within the framework of Kohn–Sham density-functional theory (KS-DFT). The new approach systematically prevents variational collapse and simplifies core-excited orbital selection within dense energy level distributions. However, careful error cancellation analysis is required to achieve accuracy comparable to all-electron methods and experiments. Combined with real-space KS-DFT implementation, this development enables large-scale simulations with both Dirichlet boundary conditions and periodic boundary conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radon-222 Charcoal Canister Steady State Model Calibrations Performed in a Highly Controlled Environmental Chamber and a Natural Indoor Environment

Charcoal canisters are a common method of 222 Rn screening. The calibrations of different batches of activated charcoal used in different canister designs are typically performed in large volume controlled environmental chambers with known and controlled radon concentration, temperature, and humidity. Radon screening could be facilitated in locations without ready access to environmental chambers if canisters could be accurately calibrated and undergo quality control in less controlled environments. This study compares charcoal canister calibrations from a highly controlled radon chamber with calibrations from a basement storage area experiencing temporally varying radon. In addition, the impacts of exposure time and spectral region of interest selection on calibration accuracy are investigated by comparing calibrations calculated using three different choices. Approximately 30 mo after calibrations were completed, groups of canisters were exposed for different durations of time to investigate measurement accuracy and calibration validity over an extended time. A digital simulation of charcoal canister kinetics was also performed to establish limits on how stable radon must be in a space for equilibrium-based calibration to be performed there. Overall, the accuracy of measurements using calibrations from each space differed by less than 10% after 2 d exposure time, showing that carefully controlled conditions are not necessary for the accurate calibration of charcoal canisters. Furthermore, measurement accuracy differed by less than 2% for different spectral region selections. Accuracy improved slightly with canister exposure duration. Simulations suggest that radon instability is most tolerable near the beginning of canister calibration exposures, but this merits further experimental study.

07 ISOTOPE AND RADIATION SOURCES↗

Optimizing Heat Recovery with Storage: Control Validation and Sensitivity Analysis of the Time-Independent Energy Recovery Plant Using Modelica

Heat recovery in large building central plants saves energy but traditionally requires simultaneous heating and cooling. The Time-Independent Energy Recovery (TIER) plant shifts this paradigm by integrating thermal energy storage (TES) to enable heat recovery regardless of concurrent demand, offering a highly efficient, space-saving solution to achieve California’s energy goals. However, its integration of heat recovery chillers, cooling-only chillers, cooling towers, and trim air-source heat pumps (ASHPs) creates growing control and sizing complexity. To overcome this, this study employs high-fidelity Modelica dynamic simulation to validate TIER control sequences and optimize equipment sizing. We translated the written Sequences of Operation into executable Control Description Language (CDL) to test logic against sub-hourly loads. This verification workflow successfully identified and resolved critical vulnerabilities, such as thermal storage freezing and equipment short-cycling, in a virtual environment prior to physical deployment. Then, the study analyzes TIER plant performance across three simulated building types in three locations, and a real building load profile, ensuring variety in heating and cooling loads, and simultaneity factors and explores sizing rules for the TES and ASHP capacity. The analysis shows that the TIER plant operates equipment efficiently leading to a plant SCOP of around 7.5 across all scenarios, higher than a traditional ASHP plant, and a viable pathway to de-risk complex system design and control through simulation to identify optimal designs that maximize energy efficiency, minimize operational costs, and ensure robust operation in varied environmental conditions, thereby facilitating the broader adoption of such a solution for large buildings.

Zanetti, Ettore↗