Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

THE FORMATION OF IRIS DIAGNOSTICS. VIII. IRIS OBSERVATIONS IN THE C ii 133.5 nm MULTIPLET

The C ii 133.5 nm multiplet has been observed by NASA’s Interface Region Imaging Spectrograph (IRIS) in unprecedented spatial resolution. The aims of this work are to characterize these new observations of the C ii lines, place them in context with previous work, and to identify any additional value the C ii lines bring when compared with other spectral lines. We make use of wide, long exposure IRIS rasters covering the quiet Sun and an active region. Line properties such as velocity shift and width are extracted from individual spectra and analyzed. The lines have a variety of shapes (mostly single-peak or double-peak), are strongest in active regions and weaker in the quiet Sun. The ratio between the 133.4 and 133.5 nm components is always less than 1.8, indicating that their radiation is optically thick in all locations. Maps of the C ii line widths are a powerful new diagnostic of chromospheric structures, and their line shifts are a robust velocity diagnostic. Compared with earlier quiet Sun observations, we find similar absolute intensities and mean line widths, but smaller redshifts; this difference can perhaps be attributed to differences in spectral resolution and spatial coverage. The C ii intensity maps are somewhat similar to those of transition region lines, but also share some features with chromospheric maps such as those from the Mg ii k line, indicating that they are formed between the upper chromosphere and transition region. C ii intensity, width, and velocity maps can therefore be used to gather additional information about the upper chromosphere.

79 ASTRONOMY AND ASTROPHYSICS↗

ON THE PROGENITOR AND EARLY EVOLUTION OF THE TYPE II SUPERNOVA 2009kr

We identify a source coincident with SN 2009kr in Hubble Space Telescope pre-explosion images. The object appears to be a single point source with an intrinsic color V - I = 1.1 {+-} 0.25 and M{sub V} = -7.6 {+-} 0.6. If this is a single star, it would be a yellow supergiant of log L/L {sub sun} {approx} 5.1 and a mass of 15{sup +5} {sub -4} M {sub sun}. The spatial resolution does not allow us yet to definitively determine if the progenitor object is a single star, a binary system, or a compact cluster. We show that the early light curve is similar to a Type IIL SN, but the prominent H{alpha} P-Cygni profiles and the signature of the end of a recombination phase are reminiscent of a Type IIP. The evolution of the expanding ejecta will play an important role in understanding the progenitor object.

79 ASTRONOMY AND ASTROPHYSICS↗

CHANDRA DISCOVERY OF A BINARY ACTIVE GALACTIC NUCLEUS IN Mrk 739

We have discovered a binary active galactic nucleus (AGN) in the galaxy Mrk 739 using Chandra and Swift BAT. We find two luminous (L{sub 2-10 keV} = 1.1 x 10{sup 43} and 1.0 x 10{sup 42} erg s{sup -1}), unresolved nuclei with a projected separation of 3.4 kpc (5.''8 {+-} 0.''1) coincident with two bulge components in the optical image. The western X-ray source (Mrk 739W) is highly variable (x 2.5) during the 4 hr Chandra observation and has a very hard spectrum consistent with an AGN. While the eastern component was already known to be an AGN based on the presence of broad optical recombination lines, Mrk 739W shows no evidence of being an AGN in optical, UV, and radio observations, suggesting the critical importance of high spatial resolution hard X-ray observations (>2 keV) in finding these binary AGNs. A high level of star formation combined with a very low L{sub [O{sub III}]/L{sub 2-10 keV}} ratio cause the AGN to be missed in optical observations. {sup 12}CO observations of the (3-2) and (2-1) lines indicate large amounts of molecular gas in the system that could be driven toward the black holes during the violent galaxy collision and be key to fueling the binary AGN. Mrk 739E has a high Eddington ratio of 0.71 and a small black hole (log M{sub BH} = 7.05 {+-} 0.3) consistent with an efficiently accreting AGN. Other than NGC 6240, this stands as the nearest case of a binary AGN discovered to date.

79 ASTRONOMY AND ASTROPHYSICS↗

Tomography of correlation functions for ultracold atoms via time-of-flight images

We propose to utilize density distributions from a series of time-of-flight images of an expanding cloud to reconstruct single-particle correlation functions of trapped ultracold atoms. In particular, we show how this technique can be used to detect off-diagonal correlations of atoms in a quasi-one-dimensional trap, where both real- and momentum-space correlations are extracted at a quantitative level. The feasibility of this method is analyzed with specific examples, taking into account finite temporal and spatial resolutions in experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Polarization and phase pulse shaping applied to structural contrast in nonlinear microscopy imaging

The spectral polarization shaping of ultrashort pulses is shown to allow retrieval of two-dimensional individual tensorial components of the second-harmonic-generation response of molecular samples in nonlinear microscopy imaging. This configuration, which cannot be performed by traditional polarization-controlled excitation, provides a structural contrast that can be directly related to information on the local symmetry and order of the sample, with submicrometric spatial resolution. Phase shaping, in addition to polarization spectral manipulation, is proposed as a possible scheme for imaging individual tensorial components without the need for a spectral information extraction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Revealing molecular structure and dynamics through high-order harmonic generation driven by mid-IR fields

High-order harmonic generation (HHG) from molecules produces spectra that are modulated by interferences that encode both the static structure and the electron dynamics initiated by interaction with the laser field. Using a midinfrared (mid-IR) laser at 1300 nm, we are able to study the region of the harmonic spectrum containing such interferences in CO{sub 2} over a wide range of intensities. This allows for isolation and characterization of interference minima arising due to subcycle electronic dynamics triggered by the laser field, which had previously been identified but not systematically separated. Our experimental and theoretical results demonstrate important steps toward combining attosecond temporal and angstrom-scale spatial resolution in molecular HHG imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Well-behaved coarse-grained model of density-functional theory

A coarse-grained version of quantum density-functional theory featuring a limited spatial resolution is shown to model formal density-functional theory (DFT). This means that all densities are ensemble-V-representable (that is, by mixed states), the intrinsic energy functional F is a continuous function of the density, and the representing external potential is the functional derivative of the intrinsic energy, in the sense of directional derivatives within the domain of F. The representing potential v[{rho}] also has a quasicontinuity property, specifically, v[{rho}]{rho} is continuous as a function of {rho}. Convergence of the intrinsic energy, coarse-grained densities, and representing potentials in the limit of coarse-graining scale going to zero are studied vis-a-vis Lieb's L{sup 1} intersection L{sup 3} theory. The intrinsic energy converges monotonically to its fine-grained (continuum) value, and coarse-grainings of a density {rho} converge strongly to {rho}. If a sequence of coarse-grained densities converges strongly to {rho} and their representing potentials converge weak-{sup *}, the limit is the representing potential for {rho}. Conversely, L{sup 3/2}+L{sup {infinity}} representability implies the existence of such a coarse-grained sequence.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Elimination of the degenerate trajectory of a single atom strongly coupled to a tilted TEM{sub 10} cavity mode

We demonstrate the trajectory measurement of the single neutral atoms deterministically using a high-finesse optical microcavity. The single atom strongly couples to the high-order transverse vacuum TEM{sub 10} mode, instead of the usual TEM{sub 00} mode, and the parameters of the system are (g{sub 10},{kappa},{gamma})=2{pi}x(20.5,2.6,2.6) MHz. The atoms simply fall down freely from the magneto-optical trap into the cavity modes, and the trajectories of the single atoms are linear. The transmission spectra of atoms passing through the TEM{sub 10} mode are detected by single-photon counting modules and are well fitted. Thanks to the tilted cavity transverse TEM{sub 10} mode, which is inclined to the vertical direction {approx}45 deg., it helps us to eliminate the degenerate trajectory of the single atom falling through the cavity and to obtain a unique atom trajectory. An atom position with a high precision of 0.1 {mu}m in the off-axis direction (axis y) is obtained, and a spatial resolution of 5.6 {mu}m is achieved in a time interval of 10 {mu}s along the vertical direction (axis x). The average velocity of the atoms is also measured from the atom transits, which determines independently the temperature of the atoms in a magneto-optical trap, 186{+-}19 {mu}K.

74 ATOMIC AND MOLECULAR PHYSICS↗

Coronary artery wall imaging in mice using osmium tetroxide and micro-computed tomography (micro-CT)

The high spatial resolution of micro-computed tomography (micro-CT) is ideal for 3D imaging of coronary arteries in intact mouse heart specimens. Previously, micro-CT of mouse heart specimens utilized intravascular contrast agents that hardened within the vessel lumen and allowed a vascular cast to be made. However, for mouse coronary artery disease models, it is highly desirable to image coronary artery walls and highlight plaques. For this purpose, we describe an ex vivo contrast-enhanced micro-CT imaging technique based on tissue staining with osmium tetroxide (OsO{sub 4}) solution. As a tissue-staining contrast agent, OsO{sub 4} is retained in the vessel wall and surrounding tissue during the fixation process and cleared from the vessel lumens. Its high X-ray attenuation makes the artery wall visible in CT. Additionally, since OsO{sub 4} preferentially binds to lipids, it highlights lipid deposition in the artery wall. We performed micro-CT of heart specimens of 5- to 25-week-old C57BL/6 wild-type mice and 5- to 13-week-old apolipoprotein E knockout (apoE{sup -/-}) mice at 10 {mu}m resolution. The results show that walls of coronary arteries as small as 45 {mu}m in diameter are visible using a table-top micro-CT scanner. Similar image clarity was achieved with 1/2000th the scan time using a synchrotron CT scanner. In 13-week-old apoE mice, lipid-rich plaques are visible in the aorta. Our study shows that the combination of OsO{sub 4} and micro-CT permits the visualization of the coronary artery wall in intact mouse hearts.

59 BASIC BIOLOGICAL SCIENCES↗

Evidence for residual elastic strain in deformed natural quartz

Residual elastic strain in naturally deformed, quartz-containing rocks can be measured quantitatively in a petrographic thin section with high spatial resolution using Laue microdiffraction with white synchrotron x-rays. The measurements with a resolution of one micrometer allow the quantitative determination of the deviatoric strain tensor as a function of position within the crystal investigated. The observed equivalent strain values of 800-1200 microstrains represent a lower bound of the actual preserved residual strain in the rock, since the stress component perpendicular to the cut sample surface plane is released. The measured equivalent strain translates into an equivalent stress in the order of {approx} 50 MPa.

58 GEOSCIENCES↗

Development of backlighting sources for a Compton Radiography diagnostic of Inertial Confinement Fusion targets

An important diagnostic tool for inertial confinement fusion is time-resolved imaging of the dense cold fuel surrounding the hot spot. Here we report on the source and diagnostic development of hard x-ray radiography and on the first radiographs of direct drive implosions obtained at photon energies up to about 100keV, where the Compton effect is the dominant contributor to the shell opacity. The radiographs of direct drive, plastic shell implosions obtained at the OMEGA laser facility have a spatial resolution of {approx}10um and a temporal resolution of {approx}10ps. This novel Compton Radiography is an invaluable diagnostic tool for Inertial Confinement Fusion targets, and will be integrated at the National Ignition Facility (NIF).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Method to Extract Spatially Resolved Polycyclic Aromatic Hydrocarbon Emission from Spitzer Spectra: Application to M51

The mid-infrared spectrum contains rich diagnostics to probe the physical properties of galaxies, among which the pervasive emission features from polycyclic aromatic hydrocarbons (PAHs) offer promising means of estimating the star formation rate (SFR) relatively immune from dust extinction. This paper investigates the effectiveness of PAH emission as a SFR indicator on subkiloparsec scales by studying the Spitzer/IRS mapping-mode observations of the nearby grand-design spiral galaxy M51. We present a new approach of analyzing the spatial elements of the spectral data cube that simultaneously maximizes spatial resolution and spatial coverage, while yielding reliable measurements of the total, integrated 5–20 μm PAH emission. We devise a strategy of extracting robust PAH emission using spectra with only partial spectral coverage, complementing missing spectral regions with properly combined mid-infrared photometry. We find that in M51 the PAH emission correlates tightly with the extinction-corrected far-ultraviolet, near-ultraviolet, and Hα emission, from scales of ∼0.4 kpc close to the nucleus to 6 kpc out in the disk of the galaxy, indicating that PAH serves as an excellent tracer of SFR over a wide range of galactic environments. But regional differences exist. Close to the active nucleus of M51 the 6.2 μm feature is weaker, and the overall level of PAH emission is suppressed. The spiral arms and the central star-forming region of the galaxy emit stronger 7.7 and 8.6 μm PAH features than the inter-arm regions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reliable and Repeatable Characterization of Optical Streak Cameras

Optical streak cameras are used as primary diagnostics for a wide range of physics and laser performance verification experiments at the National Ignition Facility (NIF). To meet the strict accuracy requirements needed for these experiments, the systematic nonlinearities of the streak cameras (attributed to nonlinearities in the optical and electronic components that make up the streak camera system) must be characterized. In some cases the characterization information is used as a guide to help determine how experiment data should be taken. In other cases the characterization data is used to “correct” data images, to remove some of the nonlinearities. In order to obtain these camera characterizations, a specific data set is collected where the response to specific known inputs is recorded. A set of analysis software routines has been developed to extract information such as spatial resolution, dynamic range, temporal resolution, etc., from this data set. The routines are highly automated, requiring very little user input and thus provide very reliable and repeatable results that are not subject to interpretation. An emphasis on quality control has been placed on these routines due to the high importance of the camera characterization information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reliable and Repeatable Characterication of Optical Streak Cameras

Optical streak cameras are used as primary diagnostics for a wide range of physics and laser experiments at facilities such as the National Ignition Facility (NIF). To meet the strict accuracy requirements needed for these experiments, the systematic nonlinearities of the streak cameras (attributed to nonlinearities in the optical and electrical components that make up the streak camera system) must be characterized. In some cases the characterization information is used as a guide to help determine how experiment data should be taken. In other cases, the characterization data are applied to the raw data images to correct for the nonlinearities. In order to characterize an optical streak camera, a specific set of data is collected, where the response to defined inputs are recorded. A set of analysis software routines has been developed to extract information such as spatial resolution, dynamic range, and temporal resolution from this data set. The routines are highly automated, requiring very little user input and thus provide very reliable and repeatable results that are not subject to interpretation. An emphasis on quality control has been placed on these routines due to the high importance of the camera characterization information.

42 ENGINEERING↗

Inspection 13.2 nm table-top full-field microscope

We present results on a table-top microscope that uses an EUV stepper geometry to capture full-field images with a halfpitch spatial resolution of 55 nm. This microscope uses a 13.2 nm wavelength table-top laser for illumination and acquires images of reflective masks with exposures of 20 seconds. These experiments open the path to the realization of high resolution table-top imaging systems for actinic defect characterization.

36 MATERIALS SCIENCE↗

Region-of-interest image reconstruction in circular cone-beam microCT

Cone-beam microcomputed tomography (microCT) is one of the most popular choices for small animal imaging which is becoming an important tool for studying animal models with transplanted diseases. Region-of-interest (ROI) imaging techniques in CT, which can reconstruct an ROI image from the projection data set of the ROI, can be used not only for reducing imaging-radiation exposure to the subject and scatters to the detector but also for potentially increasing spatial resolution of the reconstructed images. Increasing spatial resolution in microCT images can facilitate improved accuracy in many assessment tasks. A method proposed previously for increasing CT image spatial resolution entails the exploitation of the geometric magnification in cone-beam CT. Due to finite detector size, however, this method can lead to data truncation for a large geometric magnification. The Feldkamp-Davis-Kress (FDK) algorithm yields images with artifacts when truncated data are used, whereas the recently developed backprojection filtration (BPF) algorithm is capable of reconstructing ROI images without truncation artifacts from truncated cone-beam data. We apply the BPF algorithm to reconstructing ROI images from truncated data of three different objects acquired by our circular cone-beam microCT system. Reconstructed images by use of the FDK and BPF algorithms from both truncated and nontruncated cone-beam data are compared. The results of the experimental studies demonstrate that, from certain truncated data, the BPF algorithm can reconstruct ROI images with quality comparable to that reconstructed from nontruncated data. In contrast, the FDK algorithm yields ROI images with truncation artifacts. Therefore, an implication of the studies is that, when truncated data are acquired with a configuration of a large geometric magnification, the BPF algorithm can be used for effective enhancement of the spatial resolution of a ROI image.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A soft x-ray transmission grating imaging-spectrometer for the National Ignition Facility

A soft x-ray transmission grating spectrometer has been designed for use on high energy-density physics experiments at the National Ignition Facility (NIF); coupled to one of the NIF gated x-ray detectors it records 16 time-gated spectra between 250 and 1000 eV with 100 ps temporal resolution. The trade-off between spectral and spatial resolution leads to an optimized design for measurement of emission around the peak of a 100-300 eV blackbody spectrum. Performance qualification results from the NIF, the Trident Laser Facility and vacuum ultraviolet beamline at the National Synchrotron Light Source, evidence a <100 {mu}m spatial resolution in combination with a source-size limited spectral resolution that is <10 eV at photon energies of 300 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗