Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectral element method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Highly sensitive 2D X-ray absorption spectroscopy via physics informed machine learning

Abstract Improving the spatial and spectral resolution of 2D X-ray near-edge absorption structure (XANES) has been a decade-long pursuit to probe local chemical reactions at the nanoscale. However, the poor signal-to-noise ratio in the measured images poses significant challenges in quantitative analysis, especially when the element of interest is at a low concentration. In this work, we developed a post-imaging processing method using deep neural network to reliably improve the signal-to-noise ratio in the XANES images. The proposed neural network model could be trained to adapt to new datasets by incorporating the physical features inherent in the latent space of the XANES images and self-supervised to detect new features in the images and achieve self-consistency. Two examples are presented in this work to illustrate the model’s robustness in determining the valence states of Ni and Co in the LiNi x Mn y Co 1-x-y O 2 systems with high confidence.

36 MATERIALS SCIENCE↗

Optimal 1D Ly α forest power spectrum estimation – I. DESI-lite spectra

ABSTRACT The 1D Ly α forest flux power spectrum P1D is sensitive to scales smaller than a typical galaxy survey, and hence ties to the intergalactic medium’s thermal state, suppression from neutrino masses, and new dark matter models. It has emerged as a competitive framework to study new physics, but also has come with various challenges and systematic errors in analysis. In this work, we revisit the optimal quadratic estimator for P1D, which is robust against the relevant problems such as pixel masking, time evolution within spectrum, and quasar continuum errors. We further improve the estimator by introducing a fiducial power spectrum, which enables us to extract more information by alleviating the discreteness of band powers. We meticulously apply our method to synthetic Dark Energy Spectroscopic Instrument (DESI) spectra and demonstrate how the estimator overcomes each challenge. We further apply an optimization scheme that approximates the Fisher matrix to three elements per row and reduces computation time by 60 per cent. We show that we can achieve per cent precision in P1D with 5-yr DESI data in the absence of systematics and provide forecasts for different spectral qualities.

79 ASTRONOMY AND ASTROPHYSICS↗

Sensitivity of low energy brachytherapy Monte Carlo dose calculations to uncertainties in human tissue composition

Purpose: The objective of this work is to assess the sensitivity of Monte Carlo (MC) dose calculations to uncertainties in human tissue composition for a range of low photon energy brachytherapy sources: {sup 125}I, {sup 103}Pd, {sup 131}Cs, and an electronic brachytherapy source (EBS). The low energy photons emitted by these sources make the dosimetry sensitive to variations in tissue atomic number due to the dominance of the photoelectric effect. This work reports dose to a small mass of water in medium D{sub w,m} as opposed to dose to a small mass of medium in medium D{sub m,m}. Methods: Mean adipose, mammary gland, and breast tissues (as uniform mixture of the aforementioned tissues) are investigated as well as compositions corresponding to one standard deviation from the mean. Prostate mean compositions from three different literature sources are also investigated. Three sets of MC simulations are performed with the GEANT4 code: (1) Dose calculations for idealized TG-43-like spherical geometries using point sources. Radial dose profiles obtained in different media are compared to assess the influence of compositional uncertainties. (2) Dose calculations for four clinical prostate LDR brachytherapy permanent seed implants using {sup 125}I seeds (Model 2301, Best Medical, Springfield, VA). The effect of varying the prostate composition in the planning target volume (PTV) is investigated by comparing PTV D{sub 90} values. (3) Dose calculations for four clinical breast LDR brachytherapy permanent seed implants using {sup 103}Pd seeds (Model 2335, Best Medical). The effects of varying the adipose/gland ratio in the PTV and of varying the elemental composition of adipose and gland within one standard deviation of the assumed mean composition are investigated by comparing PTV D{sub 90} values. For (2) and (3), the influence of using the mass density from CT scans instead of unit mass density is also assessed. Results: Results from simulation (1) show that variations in the mean compositions of tissues affect low energy brachytherapy dosimetry. Dose differences between mean and one standard deviation of the mean composition increasing with distance from the source are observed. It is established that the {sup 125}I and {sup 131}Cs sources are the least sensitive to variations in elemental compositions while {sup 103}Pd is most sensitive. The EBS falls in between and exhibits complex behavior due to significant spectral hardening. Results from simulation (2) show that two prostate compositions are dosimetrically equivalent to water while the third shows D{sub 90} differences of up to 4%. Results from simulation (3) show that breast is more sensitive than prostate with dose variations of up to 30% from water for 70% adipose/30% gland breast. The variability of the breast composition adds a {+-}10% dose variation. Conclusions: Low energy brachytherapy dose distributions in tissue differ from water and are influenced by density, mean tissue composition, and patient-to-patient composition variations. The results support the use of a dose calculation algorithm accounting for heterogeneities such as MC. Since this work shows that variations in mean tissue compositions affect MC dosimetry and result in increased dose uncertainties, the authors conclude that imaging tools providing more accurate estimates of elemental compositions such as dual energy CT would be beneficial.

60 APPLIED LIFE SCIENCES↗

Tabletop soft x-ray absorption spectroscopy for molecular fingerprinting

For applications related to nuclear security, safeguards, and nonproliferation, it is often critical to know the molecular compositions of lanthanide- and actinide-containing samples. Spectroscopy is a widely used tool that looks at the interaction between light and matter: Different species absorb or emit light at unique wavelengths which act as signatures. However, there is a limited number of tools that can achieve high-sensitivity, accurate measurements of lanthanide and actinide molecular compositions. Candidate methods include mass spectrometry, which usually destroys at least part of the sample and requires complicated stoichiometry to guess the original sample’s molecular compositions; optical spectroscopies, which have great atomic but limited molecular sensitivities or other drawbacks which make sensing molecules difficult like limited light sources or strong absorption in the atmosphere; and nuclear spectroscopies (gamma, neutron) which also have limited sources and long (>minute) collection times. As such, the purpose of our research is to develop a new tool to better distinguish between subtle differences in molecules containing lanthanides and actinides. Soft x-ray spectroscopy is sensitive to molecular form and is minimally intrusive/nondestructive to the sample. However, soft x-ray light with sufficient brightness for spectroscopy is typically limited to user-facilities like synchrotrons or free electron lasers, where beamtimes are competitive, and work with radiological materials may be difficult or entirely prohibited. To overcome this issue, our Team has developed a custom tabletop laser-driven, soft x-ray light source which employs high harmonic generation (HHG). Soft x-ray spectroscopy can distinguish between subtly different molecules, in the spectral range which we need to study these heavy elements. A tabletop system provides an effective and affordable tool to find both the elemental and chemical specificity of lanthanide and samples. Creating a light source in the soft x-ray spectrum is difficult because these wavelengths in the range 5-20 nm (20-350 eV photon energies) only penetrate several 100s of nm in most solid materials and only reflect well in shallow, grazing incident angles. The results are applicable to nuclear forensics, because molecular fingerprinting of lanthanide and actinide samples can be used to back out the origin and processing method of nuclear materials (Skrodzki, et al.).

36 MATERIALS SCIENCE↗

Improved genome annotation through untargeted detection of pathway-specific metabolites

Background: Mass spectrometry-based metabolomics analyses have the potential to complement sequence-based methods of genome annotation, but only if raw mass spectral data can be linked to specific metabolic pathways. In untargeted metabolomics, the measured mass of a detected compound is used to define the location of the compound in chemical space, but uncertainties in mass measurements lead to “degeneracies” in chemical space since multiple chemical formulae correspond to the same measured mass. We compare two methods to eliminate these degeneracies. One method relies on natural isotopic abundances, and the other relies on the use of stableisotope labeling (SIL) to directly determine C and N atom counts. Both depend on combinatorial explorations of the “chemical space” comprised of all possible chemical formulae comprised of biologically relevant chemical elements. Results: Of 1532 metabolic pathways curated in the MetaCyc database, 412 contain a metabolite having a chemical formula unique to that metabolic pathway. Thus, chemical formulae alone can suffice to infer the presence of some metabolic pathways. Of 248,928 unique chemical formulae selected from the PubChem database, more than 95% had at least one degeneracy on the basis of accurate mass information alone. Consideration of natural isotopic abundance reduced degeneracy to 64%, but mainly for formulae less than 500 Da in molecular weight, and only if the error in the relative isotopic peak intensity was less than 10%. Knowledge of exact C and N atom counts as determined by SIL enabled reduced degeneracy, allowing for determination of unique chemical formula for 55% of the PubChem formulae. Conclusions: To facilitate the assignment of chemical formulae to unknown mass-spectral features, profiling can be performed on cultures uniformly labeled with stable isotopes of nitrogen (15N) or carbon (13C). This makes it possible to accurately count the number of carbon and nitrogen atoms in each molecule, providing a robust means for reducing the degeneracy of chemical space and thus obtaining unique chemical formulae for features measured in untargeted metabolomics having a mass greater than 500 Da, with relative errors in measured isotopic peak intensity greater than 10%, and without the use of a chemical formula generator dependent on heuristic filtering. These chemical formulae can serve as indicators for the presence of particular metabolic pathways.

59 BASIC BIOLOGICAL SCIENCES↗

Designing for cooperative grain boundary segregation in multicomponent alloys

Tailoring the nanoscale distribution of chemical species at grain boundaries is a powerful method to dramatically influence the properties of polycrystalline materials. However, classical approaches to the problem have tacitly assumed that only competition is possible between solute species. In this paper, we show that solute elements can cooperate in the way they segregate to grain boundaries: In properly targeted alloys, the different chemical species cooperate to each fill complementary grain boundary sites disfavored by the other. By developing a theoretical “spectral” approach to this problem based on quantum-accurate grain boundary site distributions, we show how grain boundaries can be cooperatively alloyed, whether by depletion or enrichment. We provide machine-learned cosegregation information for over 700 ternary aluminum-based alloys and experimentally validate the concept in one ternary alloy where cosegregation is not expected by prior models but is expected based on the cooperative model.

grain boundaries↗

Ultrasound nondestructive characterization of transparent spinel

Ceramic materials have attractive attributes for applications that experience high stresses or strain rates. Compared to metal-based systems, ceramics offer a lower areal density which reduces weight, but do not depreciate the integrity of other properties. The ability to tailor the microstructure of ceramics used in armor systems is a common way to increase specific mechanical properties or obtain certain material characteristics. Properties such as elastic modulus, hardness, and density are those that are typically desired to be enhanced. By modifying the microstructure one can obtain a ceramic with these enhanced properties as well as high optical transmission across a wide range of the electromagnetic spectrum. The testing of these properties and ballistic performance is usually destructive, expensive, and time consuming. Common assessments using ultrasonic NDE usually include spatially locating large flaws, sonic velocity measurements, and elastic property measurements. The use of acoustic spectroscopy to go beyond typical ultrasonic NDE in structural ceramics and allow for the use of a microstructural characterization tool is investigated in this paper. Ultrasound absorption by lithium fluoride precipitates in aluminate spinel (MgAl{sub 2}O{sub 4}) present as defined spectral peaks. Average heterogeneity size determination in magnesium aluminate spinel MgAl{sub 2}O{sub 4} by method of acoustic spectroscopy is shown.

36 MATERIALS SCIENCE↗

Zero Mode in a Strongly Coupled Quark Gluon Plasma

In connection with massless two-flavor QCD, we analyze the chiral symmetry restoring phase transition using three distinct gluon-quark vertices and two different assumptions about the long-range part of the quark-quark interaction. In each case, we solve the gap equation, locate the transition temperature T-c, and use the maximum entropy method to extract the dressed-quark spectral function at T>T-c. Our best estimate for the chiral transition temperature is T-c=147 +/- 8 MeV, and the deconfinement transition is coincident. For temperatures markedly above Tc, we find a spectral density that is consistent with those produced using a hard thermal loop expansion, exhibiting both a normal and plasmino mode. On a domain T is an element of[T-c, T-s] , with T-s approximate to 1.5T(c), however, with each of the six kernels we considered, the spectral function contains a significant additional feature. Namely, it displays a third peak, associated with a zero mode, which is essentially nonperturbative in origin and dominates the spectral function at T=Tc. We suggest that the existence of this mode is a signal for the formation of a strongly coupled quark-gluon plasma and that this strongly interacting state of matter is likely a distinctive feature of the QCD phase transition.

Gao, Fei↗

Adaptive Algebraic Multigrid for Finite Element Elliptic Equations with Random Coefficients

This thesis presents a two-grid algorithm based on Smoothed Aggregation Spectral Element Agglomeration Algebraic Multigrid (SA-ρAMGe) combined with adaptation. The aim is to build an efficient solver for the linear systems arising from discretization of second-order elliptic partial differential equations (PDEs) with stochastic coefficients. Examples include PDEs that model subsurface flow with random permeability field. During a Markov Chain Monte Carlo (MCMC) simulation process, that draws PDE coefficient samples from a certain distribution, the PDE coefficients change, hence the resulting linear systems to be solved change. At every such step the system (discretized PDE) needs to be solved and the computed solution used to evaluate some functional(s) of interest that then determine if the coefficient sample is acceptable or not. The MCMC process is hence computationally intensive and requires the solvers used to be efficient and fast. This fact that at every step of MCMC the resulting linear system changes, makes an already existing solver built for the old problem perhaps not as efficient for the problem corresponding to the new sampled coefficient. This motivates the main goal of our study, namely, to adapt an already existing solver to handle the problem (with changed coefficient) with the objective to achieve this goal to be faster and more efficient than building a completely new solver from scratch. Our approach utilizes the local element matrices (for the problem with changed coefficients) to build local problems associated with constructed by the method agglomerated elements (a set of subdomains that cover the given computational domain). We solve a generalized eigenproblem for each set in a subspace spanned by the previous local coarse space (used for the old solver) and a vector, component of the error, that the old solver cannot handle. A portion of the spectrum of these local eigen-problems (corresponding to eigenvalues close to zero) form the coarse basis used to define the new two-level method of our interest. We illustrate the performance of this adaptive two-level procedure with a large set of numerical experiments that demonstrate its efficiency over building the solvers from scratch.

97 MATHEMATICS AND COMPUTING↗

Rotational spectroscopy and three-wave mixing of 4-carvomenthenol: A technical guide to measuring chirality in the microwave regime

We apply chirality sensitive microwave three-wave mixing to 4-carvomenthenol, a molecule previously uncharacterized with rotational spectroscopy. We measure its rotational spectrum in the 2-8.5 GHz range and observe three molecular conformers. We describe our method in detail, from the initial step of spectral acquisition and assignment to the final step of determining absolute configuration and enantiomeric excess. Combining fitted rotational constants with dipole moment components derived from quantum chemical calculations, we identify candidate three-wave mixing cycles which were further tested using a double resonance method. Initial optimization of the three-wave mixing signal is done by varying the duration of the second excitation pulse. With known transition dipole matrix elements, absolute configuration can be directly determined from a single measurement.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

25%Eu : KGd(WO{sub 4}){sub 2} laser crystal: spectroscopy and lasing on the {sup 5}D{sub 0}{yields}{sup 7}F{sub 4} transition

25%Eu : KGd(WO{sub 4}){sub 2} crystal is grown by a modified Czochralski method and its spectral and lasing properties are studied. Generation of stimulated emission in this crystal on the {sup 5}D{sub 0}{yields}{sup 7}F{sub 4} transition of the Eu{sup 3+} ion is obtained, as far as we know, for the first time. The laser operates at room temperature at a wavelength of {approx}703 nm under pumping into the {sup 7}F{sub 0}{yields}{sup 5}D{sub 1} absorption band of the europium ion by the second harmonic of a Q-switched Nd : KGW laser ({lambda}{sub pump}= 533.6 nm). With a 9.4-mm-long active element, the output energy in the free-running regime reached 244 {mu}J, while the optical efficiency was 1.5%. (lasers and active media)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Absolute radiant power measurement for the Au M lines of laser-plasma using a calibrated broadband soft X-ray spectrometer with flat-spectral response

CEA implemented an absolutely calibrated broadband soft X-ray spectrometer called DMX on the Omega laser facility at the Laboratory for Laser Energetics (LLE) in 1999 to measure radiant power and spectral distribution of the radiation of the Au plasma. The DMX spectrometer is composed of 20 channels covering the spectral range from 50 eV to 20 keV. The channels for energies below 1.5 keV combine a mirror and a filter with a coaxial photo-emissive detector. For the channels above 5 keV the photoemissive detector is replaced by a conductive detector. The intermediate energy channels (1.5 keV < photon energy < 5 keV) use only a filter and a coaxial detector. A further improvement of DMX consists in flat-response X-ray channels for a precise absolute measurement of the photon flux in the photon energy range from 0.1 keV to 6 keV. Such channels are equipped with a filter, a Multilayer Mirror (MLM), and a coaxial detector. We present as an example the development of channel for the gold M emission lines in the photon energy range from 2 keV to 4 keV which has been successfully used on the OMEGA laser facility. The results of the radiant power measurements with the new MLM channel and with the usual channel composed of a thin titanium filter and a coaxial detector (without mirror) are compared. All elements of the channel have been calibrated in the laboratory of the Physikalisch-Technische Bundesanstalt, Germany's National Metrology Institute, at the synchrotron radiation facility BESSY II in Berlin using dedicated well established and validated methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi‐Scale Seismic Imaging of the Ridgecrest, CA, Region With Waveform Inversion of Regional and Dense Array Data

Abstract We develop an inversion procedure for deriving multi‐scale velocity models with waveform inversions of earthquake and ambient noise data at multi‐frequency bands recorded by regional and dense sensor configurations. The method is applied for the area around the 2019 Ridgecrest earthquake rupture zones, utilizing data recorded by regional stations and dense 2D and 1D arrays with station spacings of ∼5 km and ∼100 m, respectively. Starting with regional Vp, Vs models and locations of Ridgecrest aftershocks, the velocity models and event locations are improved iteratively by inversions of waveforms recorded by regional stations and the 2D array, using a minimum spectral element size of ∼600 m. Waveforms from local events recorded by dense 1D arrays across the M7.1 rupture zone with frequencies of up to 10 Hz are used to resolve small‐scale features of the rupture zone and shallow crust with a local spectral element size of 80 m. The refined models provide self‐consistent descriptions of the rupture zone and the shallow crust embedded in the regional structures. The results reveal pronounced low Vs and high Vp/Vs in the M6.4 and M7.1 rupture zones coinciding with concentrations of seismicity, and also around the Garlock fault and in several local basins. We also observe clear velocity contrasts across the Garlock fault with polarity reversals along strike and with depth. The obtained multi‐scale velocity models can be used to improve derivations of earthquake source properties, simulations of dynamic ruptures and ground motions, and the understanding of fault and tectonic processes in the region.

Geochemistry & Geophysics↗

Size dependent optical properties of Si quantum dots in Si-rich nitride/Si{sub 3}N{sub 4} superlattice synthesized by magnetron sputtering

A spectroscopic ellipsometry compatible approach is reported for the optical study of Si quantum dots (QDs) in Si-rich nitride/silicon nitride (SRN/Si{sub 3}N{sub 4}) superlattice, which based on Tauc-Lorentz model and Bruggeman effective medium approximation. It is shown that the optical constants and dielectric functions of Si QDs are strongly size dependent. The suppressed imaginary dielectric function of Si QDs exhibits a single broad peak analogous to amorphous Si, which centered between the transition energies E{sub 1} and E{sub 2} of bulk crystalline Si and blue shifted toward E{sub 2} as the QD size reduced. A bandgap expansion observed by the TL model when the size of Si QD reduced is in good agreement with the PL measurement. The bandgap expansion with the reduction of Si QD size is well supported by the first-principles calculations based on quantum confinement.

36 MATERIALS SCIENCE↗

Green luminescence of InGaN nanowires grown on silicon substrates by molecular beam epitaxy

Indium gallium nitride nanowires show promise as being prime candidates for optical devices since they can be grown with band gaps spanning the visible spectra, while at the same time can be composed of stress free material. The goal of the work presented here was to obtain InGaN nanowires producing green emission at room temperature. Two growth recipes were found to yield InGaN nanowire growth on silicon substrates using plasma-assisted molecular beam epitaxy. At room temperature the photoluminescence (PL) of wire ensembles indeed peaked at 530 nm but, in addition, it was discovered that at low temperatures the emission often covered a broader (360-700 nm) spectrum. This broad optical range indicated indium content fluctuations in individual wires, wire-to-wire fluctuations, or a combination of the two. EDX measurements performed on single wires confirmed this hypothesis and correlated well with PL data. Low temperature PL studies of InGaN individual wires also revealed interwire and intrawire inhomogeneity of emission spectra stemming from a nonuniform indium distribution. The emission quantum yield for bright single wires was extracted to be more than 50% at 4 K. The findings suggest that the wire surfaces do not efficiently quench optical emission at low temperatures. These defect-free wires offer not only a potential path for green emitters, but also as integrated phosphors for broad spectral emission.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Precision measurement of the 5 {sup 2}S{sub 1/2}- 4 {sup 2}D{sub 5/2} quadrupole transition isotope shift between {sup 88}Sr{sup +} and {sup 86}Sr{sup +}

We present a high-precision measurement of the isotope shift of the narrow quadrupole-allowed 5 {sup 2}S{sub 1/2}- 4 {sup 2}D{sub 5/2} transition in {sup 86}Sr{sup +} relative to the most abundant isotope {sup 88}Sr{sup +}. This was accomplished using high-resolution laser spectroscopy of individual trapped ions, and the measured shift is {Delta}{nu}{sub meas}{sup 88,86}=570.281(4) MHz. We also tested a recently developed and successful method for ab initio calculation of isotope shifts in alkali-metal-like atomic systems against this measurement, and our initial result of {Delta}{nu}{sub calc}{sup 88,86}=457(28) MHz is also presented. While the measurement and the calculation are in broad agreement, there is a clear discrepancy between them, and we believe that the specific mass shift was underestimated in our calculation. Our measurement provides a stringent test for further refinements of theoretical isotope shift calculation methods for atomic systems with a single valence electron.

74 ATOMIC AND MOLECULAR PHYSICS↗

Electron-phonon interaction in three-barrier nanosystems as active elements of quantum cascade detectors

The theory of electron tunneling through an open nanostructure as an active element of a quantum cascade detector is developed, which takes into account the interaction of electrons with confined and interface phonons. Using the method of finite-temperature Green’s functions and the electron-phonon Hamiltonian in the representation of second quantization over all system variables, the temperature shifts and electron-level widths are calculated and the contributions of different electron-phonon-interaction mechanisms to renormalization of the spectral parameters are analyzed depending on the geometrical configuration of the nanosystem. Due to weak electron-phonon coupling in a GaAs/Al{sub 0.34}Ga{sub 0.66}As-based resonant tunneling nanostructure, the temperature shift and rf field absorption peak width are not very sensitive to the electron-phonon interaction and result from a decrease in potential barrier heights caused by a difference in the temperature dependences of the well and barrier band gaps.

36 MATERIALS SCIENCE↗

Pulsed contact glow discharge electrification for online material quantification

Real-time elemental analysis of liquids in extreme environments remains a significant challenge for sensor development, particularly in applications such as advanced nuclear reactors. Plasma-based optical emission spectroscopy offers a promising solution. In this study, we investigate pulsed contact glow discharge electrolysis (CGDE) as an alternative plasma generation method for emission-based material quantification. Using aqueous NaCl solutions, we examine the role of discharge polarity on plasma behavior, emission characteristics, and spectral output. Our results demonstrate that cathodic discharges generate more energetic plasmas, enabling the detection of ionic species such as cerium, while anodic discharges favor atomic emission. These findings reveal a potential dual-mode sensing capability controlled by circuit configuration rather than hardware changes. Through synchronized measurements of emission, current, bubble, and spectral dynamics, we present a model in which electron emission and ohmic heating drive plasma formation. This model enhances our understanding of pulsed-CGDE and supports its potential as a versatile, adaptable platform for future deployment in high-temperature liquids such as molten salts.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗