Search NASA⌕ Search

SEARCH · Search NASA

Results for “Structural Health Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Biosensors for Real-Time Monitoring of Radiation-Induced Biologic Effects in Space

This proposal seeks to develop cellular biosensors based on dendritic polymers. Nanoscale polymer structures less than 20 nm in diameter will be used as the basis of the sensor/actuators. The structures will be designed to target into specific cells of an astronaut and be able to monitor health issues such as the exposure to radiation or infectious agents. Multiple components can be assembled on the polymers including target directors, analytical devices (such as molecular probes), magnetic particles and metals, and imaging agents. The design and assembly of these devices has been pioneered at the Center for Biologic Nanotechnology in the University of Michigan. These molecules would also be able to administer therapeutics in response to the needs of the astronaut, and act as actuators to remotely manipulate an astronaut as necessary to ensure their safety. The reporting will be accomplished either through fluorescence signal monitoring, with the use of multispectral analysis for signal interpretation, or through functional MRI. These nanosensors coupled to NEMS devices could facilitate the success and increase the safety of extended space flight.

Baker, James R., Jr.↗

Biosensors for Real-Time Monitoring of Radiation-Induced Biologic Effects in Space

This work seeks to develop cellular biosensors based on dendritic polymers. Nanoscale polymer structures less than 20 nm in diameter will be used as the basis of the biosensors. The structures will be designed to target into specific cells of an astronaut and be able to monitor health issues such as exposure to radiation. Multiple components can be assembled on the polymers including target directors, analytical devices (such as molecular probes), and reporting agents. The reporting will be accomplished through fluorescence signal monitoring, with the use of multispectral analysis for signal interpretation. These nanosensors could facilitate the success and increase the safety of extended space flight. The design and assembly of these devices has been pioneered at the Center for Biologic Nanotechnology in the University of Michigan. This period, synthesis of the test-bed biosensors continued. Studies were performed on the candidate fluorescent dyes to determine which might be suitable for the biosensor under development. Development continued on producing an artificial capillary bed as a tool for the use in the production of the fluorescence signal monitor. Work was also done on the in vitro multispectral analysis system, which uses the robotic microscope.

Baker, James R.↗

Evaluating disease surveillance strategies for early outbreak detection in contact networks with varying community structure

Disease surveillance systems allow public health agencies to respond to emerging diseases before they become widespread. Developing such systems requires identifying optimal ways to monitor in the context of an epidemic outbreak; this problem is known as sensor selection. Contact networks represent the dynamics of interaction in a population and are used to model how a disease spreads in a population and to explore strategies of sensor selection. We evaluated five sensor selection strategies on their ability to provide an early warning of a COVID-like outbreak in synthetic contact networks encapsulated in four network scenarios. Three of these scenarios assessed different aspects of community structure. The fourth scenario employed a contact network representing the population and interactions of 6.8 million people in New York City, constructed from an agent-based simulation using census and transportation data. This scenario exemplifies how sensor selection strategies may perform in a real-world, urban context. Our findings suggest that the choice of the optimal strategy depends heavily on the community structure of the network. Strategies that select highly connected nodes or maximize network coverage are the optimal surveillance strategy for outbreak detection in many network community structures. However, a naive implementation of these strategies may fail to provide an early warning at all—including in the New York City scenario. Moreover, these methods are impractical for real-world use as they require knowledge of the underlying contact network. Instead, a selection strategy that starts with a set of random nodes and then performs a random walk through a chain of neighbors reliably provides early warnings without requiring prior knowledge of the network. We find this method, called “random chain”, to be the most pragmatic for implementation in a real-world disease surveillance context.

60 APPLIED LIFE SCIENCES↗

SSTO rockets. A practical possibility

Most experts agree that single-stage-to-orbit (SSTO) rockets would become feasible if more advanced technologies were available to reduce the vehicle dry weight, increase propulsion system performance, or both. However, these technologies are usually judged to be very ambitious and very far off. This notion persists despite major advances in technology and vehicle design in the past decade. There appears to be four major misperceptions about SSTOs, regarding their mass fraction, their presumed inadequate performance margin, their supposedly small payloads, and their extreme sensitivity to unanticipated vehicle weight growth. These misperceptions can be dispelled for SSTO rockets using advanced technologies that could be matured and demonstrated in the near term. These include a graphite-composite primary structure, graphite-composite and Al-Li propellant tanks with integral reusable thermal protection, long-life tripropellant or LOX-hydrogen engines, and several technologies related to operational effectiveness, including vehicle health monitoring, autonomous avionics/flight control, and operable launch and ground handling systems.

PROPELLANT MASS FRACTION↗

Decision making for implementing non-traditional water sources: a review of challenges and potential solutions

Abstract The effects of climate change, population growth, and future hydrologic uncertainties necessitate increased water conservation, new water resources, and a shift towards sustainable urban water supply portfolios. Diversifying water portfolios with non-traditional water sources can play a key role. Rooftop harvested rainwater (RHRW), atmospheric and condensate harvesting, stormwater, recycled wastewater and greywater, and desalinated seawater and brackish water are all currently utilized and rapidly emerging non-traditional water sources. This review explores the status and trends around these non-traditional water sources, and reviews approaches and models for prioritizing, predicting, and quantifying metrics of concern. The analysis presented here suggests that understanding the challenges of location specific scenarios, socioeconomic knowledge gaps, water supply technologies, and/or water management structure is the crucial first step in establishing a model or framework approach to provide a strategy for improvement going forward. The findings of this study also suggest that clear policy guidance and onsite maintenance is necessary for variable water quality concerns of non-traditional sources like harvested rainwater and greywater. In addition, use of stormwater or reuse of wastewater raises public health concerns due to unknown risks and pathogen levels, thus rapid monitoring technologies and transparent reporting systems can facilitate their adoption. Finally, cost structure of desalination varies significantly around the world, largely due to regulatory requirements and local policies. Further reduction of its capital cost and energy consumption is identified as a hurdle for implementation. Overall, models and process analyses highlight the strength of comparative assessments across scenarios and water supply options.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Small Autonomous Aircraft Servo Health Monitoring

Small air vehicles offer challenging power, weight, and volume constraints when considering implementation of system health monitoring technologies. In order to develop a testbed for monitoring the health and integrity of control surface servos and linkages, the Autonomous Aircraft Servo Health Monitoring system has been designed for small Uninhabited Aerial Vehicle (UAV) platforms to detect problematic behavior from servos and the air craft structures they control, This system will serve to verify the structural integrity of an aircraft's servos and linkages and thereby, through early detection of a problematic situation, minimize the chances of an aircraft accident. Embry-Riddle Aeronautical University's rotary-winged UAV has an Airborne Power management unit that is responsible for regulating, distributing, and monitoring the power supplied to the UAV's avionics. The current sensing technology utilized by the Airborne Power Management system is also the basis for the Servo Health system. The Servo Health system measures the current draw of the servos while the servos are in Motion in order to quantify the servo health. During a preflight check, deviations from a known baseline behavior can be logged and their causes found upon closer inspection of the aircraft. The erratic behavior nay include binding as a result of dirt buildup or backlash caused by looseness in the mechanical linkages. Moreover, the Servo Health system will allow elusive problems to be identified and preventative measures taken to avoid unnecessary hazardous conditions in small autonomous aircraft.

Quintero, Steven↗

Stereochemical Control of Water Transport Properties in Thiol‐yne Polymers

Barrier polymers underpin almost every commercial sector, yet the needs of several emerging areas remain unmet by commercially‐available materials, including temporary orthopedic implants, transient health monitors, neural implants, and other long‐term implants. The ability to tune polymer composition independently of polymer structure positions thiol‐yne click chemistry as a promising platform to serve these emerging technologies. Here, this work describes the differences in the hierarchical structure of stoichiometrically identical materials which differ only in the proportion of the cis versus trans backbone alkene stereochemistry. Varying the isomer content in this way directs different temperature and rate dependent crystallization behavior, which affords control over micron‐scale structure. This investigation focuses on how these stereochemical features affect the water vapor permeation process by several methods and develops an understanding of how this unique structural regularity improves barrier performance relative to a commercially available water barrier polymer, poly(ethylene terephthalate).

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Fiber Optic Sensors for Health Monitoring of Morphing Airframes: Bragg Grating Strain and Temperature Sensor - Part 1

Fiber optic sensors are being developed for health monitoring of future aircraft. Aircraft health monitoring involves the use of strain, temperature, vibration and chemical sensors to infer integrity of the aircraft structure. Part 1 of this two part series describes sensors that will measure load and temperature signatures of these structures. In some cases a single fiber may be used for measuring these parameters. Part 2 will describe techniques for using optical fibers to monitor composite cure in real time during manufacture and to monitor in-service integrity of composite structures using a single fiber optic sensor capable of measuring multiple chemical and physical parameters. The facilities for fabricating optical fiber and associated sensors and the methods of demodulating Bragg gratings for strain measurement will be described.

Wood, Karen↗

Self Diagnostic Accelerometer for Mission Critical Health Monitoring of Aircraft and Spacecraft Engines

A self diagnostic accelerometer system has been shown to be sensitive to multiple failure modes of charge mode accelerometers. These failures include sensor structural damage, an electrical open circuit and most importantly sensor detachment. In this paper, experimental work that was performed to determine the capabilities of a self diagnostic accelerometer system while operating in the presence of various levels of mechanical noise, emulating real world conditions, is presented. The results show that the system can successfully conduct a self diagnostic routine under these conditions.

Lekki, John↗

Diagnosability-Based Sensor Placement through Structural Model Decomposition

Systems health management, and in particular fault diagnosis, is important for ensuring safe, correct, and efficient operation of complex engineering systems. The performance of an online health monitoring system depends critically on the available sensors of the system. However, the set of selected sensors is subject to many constraints, such as cost and weight, and hence, these sensors must be selected judiciously. This paper presents an offline design-time sensor placement approach for complex systems. Our diagnosis method is built upon the analysis of model-based residuals, which are computed using structural model decomposition. Sensor placement in this framework manifests as a residual selection problem, and we aim to find the set of residuals that achieves single-fault diagnosability of the system, uses the minimum number of sensors, and corresponds to the best model decomposition for the best distribution of the diagnosis system. We present a set of algorithms for solving this problem and compare their performance in terms of computational complexity and optimality of solutions. We demonstrate the approach using a benchmark multi-tank system.

Daigle, Matthew↗

Strain Measurement Using FBG on COPV in Stress Rupture Test

White Sands Test Facility (WSTF) was requested to perform ambient temperature hydrostatic pressurization testing of a Space Transportation System (STS) 40-in. Kevlar Composite Overwrapped Pressure Vessel (COPV). The 40-in. vessel was of the same design and approximate age as the STS Main Propulsion System (MPS) and Orbiter Maneuvering System (OMS) vessels. The NASA Engineering Safety Center (NESC) assembled a team of experts and conducted an assessment that involved a review of national Kevlar COPY data. During the review, the STS COPVs were found to be beyond their original certification of ten years. The team observed that the likelihood of STS COPV Stress rupture, a catastrophic burst before leak failure mode, was greater than previously believed. Consequently, a detailed assessment of remaining stress rupture life became necessary. Prior to STS-114, a certification deviation was written for two flights of OV-103 (Discovery) and OV-104 (Atlantis) per rationale that was based on an extensive review of the Lawrence Livermore National Laboratories, COPV data, and revisions to the STS COPV stress levels. In order to obtain flight rationale to extend the certification deviation through the end of the Program, the Orbiter Project Office has directed an interagency COPV team to conduct further testing and analysis to investigate conservatism in the stress rupture model and evaluate material age degradation. Additional analysis of stress rupture life requires understanding the fiber stresses including stress that occurs due to thru-wall composite compression in COPV components. Data must be obtained at both zero gauge pressure (pre-stress) and at the component operating pressure so that this phenomenon can be properly evaluated. The zero gauge pressure stresses are predominantly a result of the autofrettage process used during vessel manufacture. Determining these pre-stresses and the constitutive behavior of the overwrap at pressure will provide necessary information to better predict the remaining life of the STS COPVs. The primary test objective is obtaining data to verify the hypothesis of a radially oriented thru-thickness stress-riser in the COPV composite whose magnitude is a function of the applied pressure and the load history. The anticipated load dependent response follows from the constitutive behavior of the composite overwrap so data to quantify its nonlinear and time dependent response will be sought. The objective of the Fiber Braggs Gratings (FBGs) were to advance the state-of-the-art by developing techniques using FBG sensors that are capable of assessing stress-rupture degradation in Kevlar COPVs in a health monitoring mode (1). Moreover, they sought to answer questions of how embedded sensors affect overall integrity of the structure. And lastly, they sought to provide an important link in the overall stress rupture study that will help close the loop on the COPV fabrication process. NDE inspection methods will be used from start to finish and FBG will be an integral link within the overall chain.

Banks, Curtis↗

Development and Evaluation of Sensor Concepts for Ageless Aerospace Vehicles: Report 4 - Phase 1 Implementation of the Concept Demonstrator

This report describes the first phase of the implementation of the Concept Demonstrator. The Concept Demonstrator system is a powerful and flexible experimental test-bed platform for developing sensors, communications systems, and multi-agent based algorithms for an intelligent vehicle health monitoring system for deployment in aerospace vehicles. The Concept Demonstrator contains sensors and processing hardware distributed throughout the structure, and uses multi-agent algorithms to characterize impacts and determine an appropriate response to these impacts.

Abbott, David↗

Imaging Modalities Relevant to Intracranial Pressure Assessment in Astronauts: A Case-Based Discussion

Introduction: Intracranial pressure (ICP) elevation has been inferred or documented in a number of space crewmembers. Recent advances in noninvasive imaging technology offer new possibilities for ICP assessment. Most International Space Station (ISS) partner agencies have adopted a battery of occupational health monitoring tests including magnetic resonance imaging (MRI) pre- and postflight, and high-resolution sonography of the orbital structures in all mission phases including during flight. We hypothesize that joint consideration of data from the two techniques has the potential to improve quality and continuity of crewmember monitoring and care. Methods: Specially designed MRI and sonographic protocols were used to image eyes and optic nerves (ON) including the meningeal sheaths. Specific crewmembers multi-modality imaging data were analyzed to identify points of mutual validation as well as unique features of complementary nature. Results and Conclusion: Magnetic resonance imaging (MRI) and high-resolution sonography are both tomographic methods, however images obtained by the two modalities are based on different physical phenomena and use different acquisition principles. Consideration of the images acquired by these two modalities allows cross-validating findings related to the volume and fluid content of the ON subarachnoid space, shape of the globe, and other anatomical features of the orbit. Each of the imaging modalities also has unique advantages, making them complementary techniques.

Sargsyan, Ashot E.↗

Rocket Engine Oscillation Diagnostics

Rocket engine oscillating data can reveal many physical phenomena ranging from unsteady flow and acoustics to rotordynamics and structural dynamics. Because of this, engine diagnostics based on oscillation data should employ both signal analysis and physical modeling. This paper describes an approach to rocket engine oscillation diagnostics, types of problems encountered, and example problems solved. Determination of design guidelines and environments (or loads) from oscillating phenomena is required during initial stages of rocket engine design, while the additional tasks of health monitoring, incipient failure detection, and anomaly diagnostics occur during engine development and operation. Oscillations in rocket engines are typically related to flow driven acoustics, flow excited structures, or rotational forces. Additional sources of oscillatory energy are combustion and cavitation. Included in the example problems is a sampling of signal analysis tools employed in diagnostics. The rocket engine hardware includes combustion devices, valves, turbopumps, and ducts. Simple models of an oscillating fluid system or structure can be constructed to estimate pertinent dynamic parameters governing the unsteady behavior of engine systems or components. In the example problems it is shown that simple physical modeling when combined with signal analysis can be successfully employed to diagnose complex rocket engine oscillatory phenomena.

Nesman, Tom↗

Size and Structural Control of Mechanoluminescent ZnS:Mn 2+ Nanocrystals for Optogenetic Neuromodulation

Mechanoluminescent materials hold immense potential for various transformative applications, from medical imaging and diagnostics to health monitoring and wearable displays. Conventionally produced as bulk powders or microparticles, they face significant size limitations for advanced applications, particularly in biological systems and microscale devices. Here, this work presents an approach to ZnS:Mn 2+ nanocrystal synthesis that involves self-assembly and subsequent calcination. In addition to effective size control within the nanoscale, this approach promotes the formation of abundant stacking faults, significantly enhancing piezoelectric and mechanoluminescent properties by increasing trap density and reducing trap depth. Unlike mechanoluminescent materials produced using conventional methods, these nanocrystals demonstrate strong mechanoluminescence without requiring UV pre-excitation, and the light emission persists even after mechanical stress is removed. These advantageous properties make them promising candidates for optogenetic neuromodulation, as they can effectively trigger electrical signals in neurons upon ultrasound stimulation both with and without UV pre-excitation. The persistent mechanoluminescence prolongs the duration of neuronal electrical activity, providing an extended temporal window for neuromodulation compared to conventional mechanoluminescent materials. This study provides a scalable method for producing efficient mechanoluminescent nanoparticles and reveals the crucial role of particle size and defect structures in determining their mechanoluminescent behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Event-Based Data Acquisition for Acoustic Emission Monitoring of the Structural Integrity of Wind Turbine Blades [Slides]

DOE Alignment: Reduce the cost of floating offshore wind energy in deep waters to $45/MWh by 2035 from today’s estimated $150/MWh20 by: Developing operations and maintenance strategies and increasing wind turbine reliability to reduce periods of non-operation and reduce labor at sea through remote system health monitoring, inspection, and maintenance capabilities incorporating artificial intelligence and predictive maintenance.

17 WIND ENERGY↗

Mapping Boreal Forest Spruce Beetle Health Status at the Individual Crown Scale Using Fused Spectral and Structural Data

The frequency and severity of spruce bark beetle outbreaks are increasing in boreal forests leading to widespread tree mortality and fuel conditions promoting extreme wildfire. Detection of beetle infestation is a forest health monitoring (FHM) priority but is hampered by the challenges of detecting early stage (“green”) attack from the air. There is indication that green stage might be detected from vertical gradients of spectral data or from shortwave infrared information distributed within a single crown. To evaluate the efficacy of discriminating “non-infested”, “green”, and “dead” health statuses at the landscape scale in Alaska, USA, this study conducted spectral and structural fusion of data from: (1) Unoccupied aerial vehicle (UAV) multispectral (6 cm) + structure from motion point clouds (~700 pts per sq. m); and (2) Goddard Lidar Hyperspectral Thermal (G-LiHT) hyperspectral (400 to 1000 nm, 0.5 m) + SWIR-band lidar (~32 pts per sq.m). We achieved 78% accuracy for all three health statuses using spectral + structural fusion from either UAV or G-LiHT and 97% accuracy for non-infested/dead using G-LiHT. We confirm that UAV 3D spectral (e.g., greenness above versus below median height in crown) and lidar apparent reflectance metrics (e.g., mean reflectance at 99th percentile height in crown), are of high value, perhaps capturing the vertical gradient of needle degradation. In most classification exercises, UAV accuracy was lower than G-LiHT indicating that collecting ultra-high spatial resolution data might be less important than high spectral resolution information. While the value of passive optical spectral information was largely confined to the discrimination of non-infested versus dead crowns, G-LiHT hyperspectral band selection (~400, 675, 755, and 940 nm) could inform future FHM mission planning regarding optimal wavelengths for this task. Interestingly, the selected regions mostly did not align with the band designations for our UAV multispectral data but do correspond to, e.g., Sentinel-2 red edge bands, suggesting a path forward for moderate scale bark beetle detection when paired with suitable structural data.

Janice Cessna↗

The Mars 2020 Watson Imaging Subsystem of the Sherloc Investigation and Anticpated Early Results

In February 2021, the Mars 2020 Perseverance rover is anticipated to touch down in Jezero crater, Mars. Perseverance is unique in that it will conduct in situ science as well as cache samples for eventual return to Earth for analysis in terrestrial laboratories. It will explore the geologic setting within Jezero over a range of scales in order to address fundamental questions about the evolution of Mars and assess whether there is evidence of past or present Martian life. The Wide Angle Topographic Sensor for Operations and eNgineering (WATSON), one of two imaging subsystems within the Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) instrument[1,2], acquires images that support scientific study of Jezero crater and sample acquisition, as well as rover and instrument operations(Fig. 1).WATSON serves a number of roles; it 1) provides color context imaging of SHERLOC and Planetary Instrument for X-Ray Litho chemistry (PIXL)analysis locations, placing the spatial distribution of organics and mineralogy detected by SHERLOC and the elemental maps generated by PIXL within the context of rock texture and structure; 2)acquires stand-alone observations of rock structures and textures from the outcrop to the grain scale; and 3)images rover components and other instruments to monitor their health and condition. We plan to present images acquired within the first ~30 sols of operations.

M E Minitti↗