Search NASA⌕ Search

SEARCH · Search NASA

Results for “System reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Quantifying the Protectability of Power Systems for Restoration Applications

With the increasing availability of distributed energy resources, controllable switches, and advanced metering infrastructure, distribution systems are exploring opportunities for improving system reliability through fault location, isolation, and service restoration. During permanent outages, this requires islanding microgrids and/or reconfiguration of the feeders; however, it is critical to assess the protection of the islanded/reconfigured networks before transition because the rated load and fault current conditions change. This paper presents a novel “protectability” metric that quantifies the protection performance and allows the operators to compare the effectiveness of the protection between two or more possible reconfiguration and islanding approaches. We present the mathematical formulation and assumptions for the metric. Multiple configurations of the Electric Power Research Institute J1 feeder, both in grid-connected and weak-sourced islanded operation, are used to demonstrate the performance of the metric with reference to overcurrent protection. Takeaways for future studies on system planning integration are provided.

distributed energy resources↗

Transportation Energy Analytics Dashboard (TEAD)

The investment decisions within the nation’s transportation sector have traditionally been prioritized and measured against safety and travel efficiency goals. Increasingly, federal, state, and local policies are requiring consideration of energy use and emissions in the design of our transportation infrastructure. Yet the processes, analytics, and knowledge to include these new metrics into transportation decisions are lacking. Although targeted studies and before and after analysis are performed from time to time, no comprehensive real-time monitoring systems provide energy and emissions to the same level as congestion and safety. To address this gap, the Center for Advanced Transportation Technology (CATT Lab) and the Maryland Transportation Institute (MTI) at the University of Maryland (UMD), in partnership with the National Renewable Energy Laboratory (NREL), have developed a Transportation Energy Analytics Dashboard, or TEAD, to raise awareness of the energy and emission impacts to the same level of observability as that of safety and mobility concerns. The overall goal of this project was to develop and demonstrate an online tool to monitor transportation energy use and emissions in real-time and to archive this data for retrospective analysis. By combining surface transportation energy and emissions evaluation capability with more traditional safety, mobility and reliability system evaluation, our goal is for TEAD to create a dynamic new paradigm in transportation systems management and performance analyses, for both real-time traffic operations, and longer-term planning for project and program investment decision-making.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Digital Assurance for Grid Reliability in the Era of Large Load Growth

The rapid expansion of large electric loads is reshaping the operational and regulatory landscape of the U.S. electric grid. These facilities are reaching new scales of expansion, now exceeding a gigawatt per site, and their highly sensitive, digitally driven behaviors introduce new reliability risks. Recent grid events, including large load losses following routine transmission disturbances, highlight the consequences of limited ride-through capability, inconsistent protection settings, inadequate modeling, and lack of behind-the-meter visibility. Parallels to earlier integration challenges of new grid technologies suggest that the grid’s existing processes, standards, and interconnection frameworks are no longer adequate for emerging large loads. This brief synthesizes lessons from the evolution of inverter-based resource regulation and applies them to large-load integration. It identifies critical gaps in modeling accuracy, interconnection processes, performance standards, and compliance mechanisms. Technical recommendations emphasize advanced monitoring, improved modeling, coordinated communication protocols, modernized substations, and structured behind-the-meter control schemes. Collectively, these measures provide a roadmap to maintain bulk power system reliability while enabling the continued growth of large, electrified digital infrastructure.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

High Performance Building Facade Solutions - PIER Final Project Report

Building facades directly influence heating and cooling loads and indirectly influence lighting loads when daylighting is considered, and are therefore a major determinant of annual energy use and peak electric demand. Facades also significantly influence occupant comfort and satisfaction, making the design optimization challenge more complex than many other building systems.This work focused on addressing significant near-term opportunities to reduce energy use in California commercial building stock by a) targeting voluntary, design-based opportunities derived from the use of better design guidelines and tools, and b) developing and deploying more efficient glazings, shading systems, daylighting systems, facade systems and integrated controls. This two-year project, supported by the California Energy Commission PIER program and the US Department of Energy, initiated a collaborative effort between The Lawrence Berkeley National Laboratory (LBNL) and major stakeholders in the facades industry to develop, evaluate, and accelerate market deployment of emerging, high-performance, integrated facade solutions. The LBNL Windows Testbed Facility acted as the primary catalyst and mediator on both sides of the building industry supply-user business transaction by a) aiding component suppliers to create and optimize cost effective, integrated systems that work, and b) demonstrating and verifying to the owner, designer, and specifier community that these integrated systems reliably deliver required energy performance. An industry consortium was initiated amongst approximately seventy disparate stakeholders, who unlike the HVAC or lighting industry, has no single representative, multi-disciplinary body or organized means of communicating and collaborating. The consortium provided guidance on the project and more importantly, began to mutually work out and agree on the goals, criteria, and pathways needed to attain the ambitious net zero energy goals defined by California and the US.A collaborative test, monitoring, and reporting protocol was also formulated via the Windows Testbed Facility in collaboration with industry partners, transitioning industry to focus on the importance of expecting measured performance to consistently achieve design performance expectations. The facility enables accurate quantification of energy use, peak demand, and occupant comfort impacts of synergistic facade-lighting-HVAC systems on an apples-to-apples comparative basis and its data can be used to verify results from simulations. Emerging interior and exterior shading technologies were investigated as potential near-term, low-cost solutions with potential broad applicability in both new and retrofit construction. Commercially-available and prototype technologies were developed, tested, and evaluated. Full-scale, monitored field tests were conducted over solstice-to-solstice periods to thoroughly evaluate the technologies, uncover potential risks associated with an unknown, and quantify performance benefits. Exterior shading systems were found to yield net zero energy levels of performance in a sunny climate and significant reductions in summer peak demand. Automated interior shading systems were found to yield significant daylighting and comfort-related benefits.In support of an integrated design process, a PC-based commercial fenestration (COMFEN) software package, based on EnergyPlus, was developed that enables architects and engineers to quickly assess and compare the performance of innovative facade technologies in the early sketch or schematic design phase. This tool is publicly available for free and will continue to improve in terms of features and accuracy. Other work was conducted to develop simulation tools to model the performance of any arbitrary complex fenestration system such as common Venetian blinds, fabric roller shades as well as more exotic innovative facade systems such as optical louver systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Framework to Support Generator Ramping Uncertainty Analysis and Visualization

Power system operation requires maintaining a continuous balance between system demand and generation within certain constraints. Traditionally, the balancing processes are based on deterministic models, which do not consider possible random deviations of system generation and load from their predicted values. With the increasing penetration of the renewable generation, unexpected balancing problems can happen due to the deviations. This can result in serious risks to system reliability and efficiency. When the available balancing reserve is not enough to cover the predicted net load range with uncertainty, deficiency of balancing needs occurs. In this case, it is necessary to commit or de-commit additional conventional generators to achieve the desired confidence level for the balancing needs. The framework is built for solving this problem. The ramping tool engine is used to predict additional balancing requirements caused by the variability and uncertainty of the renewable energy, under the constraints of the generation ramping capability and interchange schedule. The web browser- based GUI is used to visualize the data in web-environment, which provides flexibility to allow user to see the ramping outputs in any platform. The GOSS structure provides strong support to allow easy communication between ramping engine, and system inputs, as well as the GUI.

Chen, Yousu↗

Marginal Cost Pricing in a World without Perfect Competition: Implications for Electricity Markets with High Shares of Low Marginal Cost Resources

A common approach to regulating electricity is through auction-based competitive wholesale markets. The goal of this approach is to provide a reliable supply of power at the lowest reasonable cost to the consumer. This necessitates market structures and operating rules that ensure revenue sufficiency for all generators needed for resource adequacy purposes. Wholesale electricity markets employ marginal-cost pricing to provide cost-effective dispatch such that resources are compensated for their operational costs. However, marginal-cost pricing alone cannot guarantee cost recovery outside of perfect competition, and electricity markets have at least six attributes that preclude them from functioning as perfectly competitive markets. These attributes include market power, externalities, public good attributes, lack of storage, wholesale price caps, and ineffective demand curve. Until (and unless) these failures are ameliorated, some form of corrective action(s) will be necessary to improve market efficiency so that prices can correctly reflect the needed level of system reliability. Many of these options necessarily involve some form of administrative or out-of-market actions, such as scarcity pricing, capacity payments, bilateral or other out-of-market contracts, or some hybrid combination. A key focus with these options is to create a connection between the electricity market and long-term reliability/loss-of-load expectation targets, which are inherently disconnected in the native markets because of the aforementioned market failures. The addition of variable generation resources can exacerbate revenue sufficiency and resource adequacy concerns caused by these underlying market failures. Because variable generation resources have near-zero marginal costs, they effectively suppress energy prices and reduce the capacity factors of conventional generators through the merit-order effect in the simplest case of a convex market; non-convexities can also suppress prices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demand Response Resource Quantification with Detailed Building Energy Models

Demand response is a broad suite of technologies that enables changes in electrical load operations in support of power system reliability and efficiency. Although demand response is not a new concept, there is new appetite for comprehensively evaluating its technical potential in the context of renewable energy integration. The complexity of demand response makes this task difficult -- we present new methods for capturing the heterogeneity of potential responses from buildings, their time-varying nature, and metrics such as thermal comfort that help quantify likely acceptability of specific demand response actions. Computed with an automated software framework, the methods are scalable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermal Evaluation of CCS and NACS Reference Devices and Adapters

A review of NLR's work in charging system reliability for charging inlets, connectors, and adapters. The review includes a detailed discussion on (a) the development of a reference device for the thermal performance of charging connectors and adapters, (b) evaluation of charging adapters and their thermal warning and shutdown response, (c) implications of side-load from real-world implementations, and (d) strengthening the conformance evaluation for end caps based on field data.

33 ADVANCED PROPULSION SYSTEMS↗

Development of a Spouted Bed Reactor for Chemical Looping Combustion

We have investigated a novel gas/solid contacting configuration for chemical looping combustion (CLC) with potential operating benefits. CLC configurations are typically able to achieve high fuel conversion efficiencies at the expense of high operating costs and low system reliability. The spouted fluid bed (SB) was identified as an improved reactor configuration for CLC, since it typically exhibits high heat transfer rates and offers the ability to use lower gas flows for material movement compared to bubbling beds (BB). Multiphase Flow with Interphase eXchanges (MFIX) software was used to establish a spouted fluid bed reactor design. An experimental setup was built to supplement the model. The experimental setup was also modified for testing under high temperature, reacting conditions (1073–1273 K). The setup was operated in either a spouted fluid bed or a bubbling bed regime to compare the performance attributes of each. Results for the reactor configurations are presented for CLC using a mixture of carbon monoxide and hydrogen as fuel. Compared to the bubbling bed, the spouted fluid bed reactor achieved an equivalent or better fuel conversion at a lower pressure drop over the material bed. The spouted fluid bed design represents a viable configuration to improve gas/solid contacting for efficient fuel conversion, lower energy requirements for material movement and increase operational robustness for CLC. The research laid the groundwork for future research into a multi-phase reacting flow CLC system. The system will be developed from computational fluid dynamic modeling and pilot-scale testing to expedite the development of CLC technologies.

Energy & Fuels↗

The OVIS analysis architecture.

This report summarizes the current statistical analysis capability of OVIS and how it works in conjunction with the OVIS data readers and interpolators. It also documents how to extend these capabilities. OVIS is a tool for parallel statistical analysis of sensor data to improve system reliability. Parallelism is achieved using a distributed data model: many sensors on similar components (metaphorically sheep) insert measurements into a series of databases on computers reserved for analyzing the measurements (metaphorically shepherds). Each shepherd node then processes the sheep data stored locally and the results are aggregated across all shepherds. OVIS uses the Visualization Tool Kit (VTK) statistics algorithm class hierarchy to perform analysis of each process's data but avoids VTK's model aggregation stage which uses the Message Passing Interface (MPI); this is because if a single process in an MPI job fails, the entire job will fail. Instead, OVIS uses asynchronous database replication to aggregate statistical models. OVIS has several additional features beyond those present in VTK that, first, accommodate its particular data format and, second, improve the memory and speed of the statistical analyses. First, because many statistical algorithms are multivariate in nature and sensor data is typically univariate, interpolation of data is required to provide simultaneous observations of metrics. Note that in this report, we will refer to a single value obtained from a sensor as a measurement while a collection of multiple sensor values simultaneously present in the system is an observation. A base class for interpolation is provided that abstracts the operation of converting multiple sensor measurements into simultaneous observations. A concrete implementation is provided that performs piecewise constant temporal interpolation of multiple metrics across a single component. Secondly, because calculations may summarize data too large to fit in memory OVIS analyses batches of observations at a time and aggregates these intermediate intra-process models as it goes before storing the final model for inter-process aggregation via database replication. This reduces the memory footprint of the analysis, interpolation, and the database client and server query processing. This also interleaves processing with the disk I/O required to fetch data from the database - also improving speed. This report documents how OVIS performs analyses and how to create additional analysis components that fetch measurements from the database, perform interpolation, or perform operations on streamed observations (such as model updates or assessments). The rest of this section outlines the OVIS analysis algorithm and is followed by sections specific to each subtask. Note that we are limiting our discussion for now to the creation of a model from a set of measurements, and not including the assessment of observations using a model. The same framework can be used for assessment but that use case is not detailed in this report.

97 MATHEMATICS AND COMPUTING↗

The Prospects for Pumped Storage Hydropower in Alaska

Key Takeaways: The resource mapping analysis confirmed that numerous locations in Alaska are suitable for the development of pumped storage hydropower (PSH) projects, both larger grid scale projects and smaller projects that could be suitable for remote communities; The resource assessment for larger, grid-scale projects showed the potential for more than 1,800 closed-loop systems in Alaska, with a total energy storage capacity of about 4 terawatt hours (TWh); Because of their small reservoir sizes and dam heights, many locations were identified as potentially suitable for small-scale PSH systems. Nearly 50% of the identified potentially suitable small-scale PSH sites are in Southeast Alaska; PSH candidate sites were part of the optimal capacity expansion solution in all scenarios analyzed for the Railbelt system. Depending on the scenario, the new PSH capacity that the model selected for the analysis period until 2046 ranged from 300 MW to 600 MW. The locations and timing of new PSH investments vary in different scenarios; Lithium-ion batteries were also selected a source of new generating capacity in all analyzed scenarios for the Railbelt system, indicating that the system will need a mix of short- and long-duration energy storage to support variable renewable energy sources and provide system reliability in the future; For rural communities, analysis results showed that PSH suitability is very site-specific; in addition to diesel fuel costs and PSH capital costs, suitability depends heavily on available renewable resources and existing infrastructure (e.g., reservoirs, transmission access and construction road access); The analysis for rural communities also showed that PSH projects with 10-hour energy storage are likely to be more economical for remote community applications in Alaska than those with larger reservoirs that could provide 10 days of energy storage; Lithium-ion batteries seem to be an economically more viable energy storage option for small, remote communities in Alaska.

13 HYDRO ENERGY↗

RESULTS FROM RECENT SCIENCE AND TECHNOLOGY INVESTIGATIONS TARGETING CHROMIUM IN THE 100D AREA HANFORD SITE WASHINGTON USA

Sodium dichromate was used in Hanford's 100D Area during the reactor operations period of 1950 to 1964 to retard corrosion in the reactor cooling systems. Some of the sodium dichromate was released to the environment by spills and/or leaks from pipelines used to deliver the chemical to water treatment plants in the area. As a result, hexavalent chromium [Cr(VI)] has migrated through the vadose zone to the groundwater and contaminated nearly 1 km{sup 2} of groundwater to above the drinking water standard of 48 {micro}g/L. Three technology tests have recently been completed in this area to characterize the source area of the plumes and evaluate alternative methods to remove Cr(VI) from groundwater. These are (1) refine the source area of the southern plume; (2) test electrocoagulation as an alternative groundwater treatment technology; and (3) test the ability to repair a permeable reactive barrier by injecting micron or nanometer-size zero-valent iron (ZVI). The projects were funded by the US Department of Energy as part of a program to interject new technologies and accelerate active cleanup. Groundwater monitoring over the past 10 years has shown that Cr(VI) concentrations in the southern plume have not significantly diminished, strongly indicating a continuing source. Eleven groundwater wells were installed in 2007 and 2008 near a suspected source area and monitored for Cr(VI) and groundwater levels. Interpretation of these data has led to refinement of the source area location to an area of less than 1 hectare (ha, 2.5 acres). Vadose zone soil samples collected during drilling did not discover significant concentrations of Cr(VI), indicating the source is localized, with a narrow wetted path from the surface to the water table. Electrocoagulation was evaluated through a pilot-scale treatability test. Over 8 million liters of groundwater were treated to Cr(VI) concentrations of {le}20 {micro}g/L. The test determined that this technology has the potential to treat Cr(VI) to these low levels, but system reliability and operational complexity rendered electrocoagulation less cost effective than the baseline technology of ion exchange. Laboratory and field tests were conducted to evaluate the practicality of injecting ZVI into the aquifer to increase the lifespan and effectiveness of an existing permeable reactive barrier. From a database of 30 ZVI materials, 6 were chosen and tested in the laboratory to determine their geochemical and physical performance under simulated 100D aquifer conditions. The best-performing ZVI was injected into the aquifer and met the primary goals of communicating the iron at least 7 meters from the injection point and reducing the aquifer to transform mobile Cr(VI) to trivalent chromium Cr(III), which is effectively immobile in the aquifer.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Trends in SiC MOSFET Threshold Voltage and ON-Resistance Measurements from Thermal Cycling and Electrical Switching Stresses: Preprint

Integrating SiC power MOSFETs is very attractive for advancing power electronic systems, yet the system reliability with new devices remains in question. This work presents two accelerated test experiments to further investigate the packaging and semiconductor failures of a TO-247 SiC MOSFET. First, a variation on power cycling experiments -- switching cycling -- is introduced. Traditional power cycling experiments utilize conduction losses to self-heat the device where a large temperature swing causes degradation at the packaging level. However, by decreasing the on-time such that the device only turns on and immediately turns off, the temperature swing is decreased and the semiconductor itself is degraded. This work shows experimental device degradation caused by continuous switching events - switching cycling, at 90% of the device's breakdown voltage. Second, thermal cycling experiments were conducted between -40 degrees C and 175 degrees C to observe degradation in the mechanical packaging of the device. Experimentally-measured changes in threshold voltage and ON-resistance are recorded in both experiments and compared. These results also illustrate the spectrum between device and package degradation from accelerated test methods.

33 ADVANCED PROPULSION SYSTEMS↗

Modeling distributed energy resource aggregations in security constrained unit commitment and economic dispatch

The Federal Energy Regulatory Commission (FERC) recently issued Order 2222, which requires all wholesale electricity markets in the US to allow distributed energy resources (DERs) to participate in the market as aggregated resources. These DER aggregations may be composed of many individual resources that are offered and dispatched by the market as a single entity. We present here a model of a distributed energy resource aggregator (DERA) that is scheduled by a market operator’s security constrained unit commitment (SCUC) and security constrained economic dispatch (SCED). The DERA model includes constraints for battery energy storage systems (BESSs), demand response resources (DRRs), and a simple distributed energy resource (DER). This paper describes a model for each resource type and presents two methods for the DERA to generate market offer curves: a profit-maximizing optimization to compute cost curves and a direct cost algorithm to determine dispatch costs for each resource and combine into cost curves. Once all participating DERAs are scheduled in SCUC/SCED, the model is then modified to dispatch individual DERs to maximize profit or minimize schedule deviation of the DERAs. A simulation of a representative day illustrates the DERA offers, the scheduled generation, and the DERA dispatch. Findings show the potential for unavoidable schedule deviations due to internal DER constraints and due to economic incentives to deviate from the SCUC/SCED schedules. This highlights the importance of DERA offer construction on market efficiency and system reliability. Novel aspects of our approach include: (1) We consider the asymmetry of price incentives impacting DERAs from the wholesale market compared to those impacting consumers from the retail market, as imposed by current regulations and laws. (2) We model aggregate consumer response through statistically parameterizable utility functions rather than a potentially impractical approach of modeling each individual consumer. (3) We show how to use the DERA operational dispatch model to create offers into the wholesale electricity market. (4) We show how DERAs may fail to meet their scheduled dispatch because the market offer format may not permit them to fully express their operational features such as intertemporal costs and constraints to the market.

aggregations↗

Protecting and Defending against Autonomous Control Systems and Digital Twin Cyber Attacks: Response Strategy for Hyperparameter attacks of Digital Twin Machine Learning Models in Nuclear Power Plants (Final)

Navigating through the complex tapestry of technological advancements, "Response Strategy for Hyperparameter attacks of Digital Twin Machine Learning Model in Nuclear Power Plants" stands at the intersection of cybersecurity and nuclear power plant operations, embarking on a journey through the intricacies of securing digital twins against malicious cyber activities. As nuclear power plants progressively integrate digital twin technology and machine learning models to optimize operations and ensure system reliability, they inadvertently expose themselves to a new spectrum of vulnerabilities, notably in the realm of hyperparameter attacks. Hyperparameters, integral in machine learning model tuning and optimal performance of digital twins, have emerged as a target for adversaries aiming to destabilize the predictive capabilities and therefore, the operational accuracy of these digital entities within critical infrastructures like nuclear plants. This paper, therefore, meticulously threads the needle through the development of a robust response strategy, poised to shield these digital reflections against calculated hyperparameter manipulations, ensuring that the digital twin can effectively and securely function as a reliable proxy for its physical counterpart. The ensuing sections delve into the orchestrated maelstrom of multi-rate time-changing intelligent coordinated hyperparameter attacks and the implementation of event-triggered predictive control, laying down a structured, predictive, and responsive framework that safeguards the nexus where the digital and physical realms of nuclear power plants coalesce. The operational integrity of digital twins in nuclear power plants depends critically on the security of machine learning hyperparameters. This study makes two different contributions. First, a decision-based idea known as a multi-rate time changing intelligent coordinated hyperparameter attack is put forth. In this attack, many hyperparameters are repeatedly changed using both random and intelligent optimal techniques by the attacker. These assaults introduce varied rates at different attack steps, compromise various amounts of hyperparameters, and improve stealth and flexibility. Second, a technique is developed for event triggered predictive control to rapidly respond to potential hyperparameter attacks. This control integrates a sliding window framework, retaining a history of previous data points and employing linear regression to predict the next data point from the current dataset. The control gain K is determined using the Lyapunov-Krasovskii method, and subsequently, an action is developed. Finally, the outcome of the simulation demonstrates the viability of the proposed method for defending nuclear power plant digital twins from hyperparameter attacks.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Use of Digital Real-Time Simulation and Optimization to Identify Maximum Real Power Injection on the Banshee Distribution Network: Preprint

This study investigates the hosting capacity of the Banshee Distribution Network by optimizing the real power injection at carefully selected Distributed Energy Resource (DER) locations. The analysis is conducted within the framework of power system operational constraints, including bus voltage ranges, thermal line ratings, and transformer loading limits. A Python-based Genetic Algorithm (GA), implemented using the PyGAD library, is employed to iteratively identify the optimal power injection configuration that maximizes network utilization while preserving system reliability. The methodology integrates a real-time simulation environment using the Real-Time Digital Simulator (RTDS), allowing high-fidelity evaluation of power flow and voltage behavior under each proposed injection scenario. By coupling the optimization algorithm with real-time simulation feedback, this approach ensures that both static and dynamic constraints are enforced during the evaluation process. The GA leverages evolutionary operators such as selection, crossover, and mutation to navigate the nonlinear search space efficiently. The results of the study delineate the feasible hosting capacity at three targeted buses, reflecting maximum real power levels that can be injected without causing voltage violations, transformer overloading, or line congestion. These findings provide a decision- support tool for distribution planners and utilities aiming to integrate higher penetrations of DERs in existing infrastructure. Additionally, the work lays the foundation for extending such optimization techniques to multi-objective formulations, including economic dispatch and reactive power coordination, in future studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Use of Digital Real-Time Simulation and Optimization to Identify Maximum Real Power Injection on Banshee Distribution Network

This study investigates the hosting capacity of the Banshee Distribution Network by optimizing the real power injection at carefully selected Distributed Energy Resource (DER) locations. The analysis is conducted within the framework of power system operational constraints, including bus voltage ranges, thermal line ratings, and transformer loading limits. A Python-based Genetic Algorithm (GA), implemented using the PyGAD library, is employed to iteratively identify the optimal power injection configuration that maximizes network utilization while preserving system reliability. The methodology integrates a real-time simulation environment using the Real-Time Digital Simulator (RTDS), allowing high-fidelity evaluation of power flow and voltage behavior under each proposed injection scenario. By coupling the optimization algorithm with real-time simulation feedback, this approach ensures that both static and dynamic constraints are enforced during the evaluation process. The GA leverages evolutionary operators such as selection, crossover, and mutation to navigate the nonlinear search space efficiently. The results of the study delineate the feasible hosting capacity at three targeted buses, reflecting maximum real power levels that can be injected without causing voltage violations, transformer overloading, or line congestion. These findings provide a decision- support tool for distribution planners and utilities aiming to integrate higher penetrations of DERs in existing infrastructure. Additionally, the work lays the foundation for extending such optimization techniques to multi-objective formulations, including economic dispatch and reactive power coordination, in future studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reserve and energy scarcity pricing in United States power markets: A comparative review of principles and practices

Here, errors in forecasting load and renewable-based generation in restructured power systems mean that independent system operators (ISOs) must procure sufficient operating reserves to keep the real-time operation of the system reliable and secure. But when procured reserves turn out to be insufficient in real-time due to the lack of resource capacity or ramp capability, operators often set higher prices for reserves and energy to encourage more supply, and to motivate consumers to decrease usage or shift it to other times. This procedure, which is called scarcity or shortage pricing, is a core feature of U.S. electricity markets. It is receiving increased attention from market designers and stakeholders because scarcity will become more important for spot price formation in the future with the increased penetration of zero-marginal cost renewables, and the shrinking role of fuel costs in setting prices. Scarcity pricing is implemented in various ways by different ISOs. These differences have practical implications for the level of prices and incentives for investment, operations, and demand modification. In this paper, general approaches and specific calculation procedures for reserve and energy scarcity pricing practices and calculations across the seven ISO-based U.S. power markets are reviewed and compared. A consistent terminology is used to facilitate the comparison. Current scarcity pricing practices are grouped into three approaches: (1) imposing an adder after the spot market is run; (2) including stepwise demand curves within market clearing procedures for non-contingency reserve products (e.g., the novel flexiramp product), which tends to yield longer right tails for energy scarcity premium curves; and (3) having stepwise demand curves for traditional contingency reserve products only, which results in shorter right tails in energy scarcity curves. A generic numerical example is presented to highlight the large practical differences among the reserve scarcity pricing approaches and specific implementations. To further investigate factors that contribute the most to demand curves differences among ISOs, a sensitivity analysis is performed. This analysis shows that the largest source of differences among the curves is the scarcity prices assumed in the case of severe scarcity, while the number of steps used and whether flexiramp is considered also yields important differences in scarcity prices. As renewable penetration increases, it will become increasingly crucial to employ administrative demand curves so that spot prices more effectively motivate supply and demand adjustments exactly when and where they are needed. This study shows that the different assumptions yield very different scarcity premiums for reserves and energy, and are likely to provide divergent incentives for resources to respond to shortages. It is concluded that to promote market efficiency, a reserve shortage demand curve should have at least three features: inclusion of the marginal value of reserve products at each shortage level, consideration of the magnitude and probability of supply contingencies, and avoidance of abrupt price discontinuities that can cause excessively volatile market outcomes.