Search NASA⌕ Search

SEARCH · Search NASA

Results for “Systems Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Influence of Phase-Change Materials and Operating Periods on Load Shifting for Thermal Storage Heat Pumps in European Climate Zones

As the reliance on heat pumps (HPs) for space conditioning increases worldwide, ex-tensive grid strains during utility peak hours are expected. Significant research efforts focus on investigating the use of integrated thermal energy storage (TES) systems to reduce peak energy demands. Conventionally, TES systems are often integrated to store and provide either cooling or heating, but not both. In this work, a single room-temperature phase-change material (PCM)-TES was integrated for dual-mode opera-tion with an R290 air-to-water 10.5 kW (3-Ton) HP. Two PCM melting temperatures (17°C, 22°C) were assessed to investigate their impact on system performance and cost reductions for Milan, Italy (4A); Barcelona, Spain (3A); and Oslo, Norway (6A). HP and HP-TES performance maps were generated using Modelica-based transient models and co-simulated with a prototype residential building using the Spawn of En-ergyPlusTM with simple rule-based controls. Our simulations indicate that PCM-17°C provided annual cost savings at higher peak-to-off-peak cost ratios, as the demand re-duction dominated the savings potential. The recharge energy costs and requirements became more dominant at lower cost ratios, making PCM-22°C more beneficial at lower cost ratios. Finally, despite Oslo's heating-dominated climate, the utility peak hours favor cooling demand reductions, making PCM-17°C more appealing. In all cases, the cost savings potential stabilized between 4 – 10% regardless of cost ratio, suggesting that system-level component and operation control optimization is required to maximize cost savings further.

25 ENERGY STORAGE↗

Discovery, characterization, and application of chromosomal integration sites in the hyperthermophilic archaeon Sulfolobus islandicus

Sulfolobus islandicus , an emerging archaeal model organism, offers unique advantages for metabolic engineering and synthetic biology applications owing to its ability to thrive in extreme environments. Although several genetic tools have been established for this organism, the lack of well-characterized chromosomal integration sites has limited its potential as a cellular factory. Here, in this work, we systematically identified and characterized 13 artificial CRISPR RNAs targeting eight integration sites in S. islandicus using the CRISPR-COPIES pipeline and a multi-omics-informed computational workflow. We leveraged the endogenous CRISPR-Cas system to integrate the reporter gene lacS and validated heterologous expression through a β-galactosidase assay, revealing significant positional effects. As a proof of concept, we utilized these sites to genetically manipulate lipid ether composition by overexpressing glycerol dibiphytanyl glycerol tetraether (GDGT) ring synthase B (GrsB). This study expands the genetic toolbox for S. islandicus and advances its potential as a robust platform for archaeal synthetic biology and industrial biotechnology.

59 BASIC BIOLOGICAL SCIENCES↗

EMT Workshop Pre-session

The dataset contains installation instructions for the EMT Workshop 2026 with a python script and PSCAD file for verification of installation for the participants.

Sahu, Vibhuti [ORNL] (ORCID:000000034808527X)↗

Integrating Resilience Planning in Distribution System Planning

Electric utilities, regulators, and stakeholders face increasing risks of severe storms, freezes, floods, and heat waves damaging grid infrastructure and causing power outages—and increasing risks of utility equipment igniting wildfires. At the same time, customer electricity rates have risen substantially in recent years, due in part to replacing aging infrastructure and improving resilience to natural hazards and physical threats. To address these challenges, utilities are beginning to move beyond traditional, siloed planning processes to balance resilience with other fundamental grid objectives such as affordability, reliability, safety, and serving new loads. This study presents a framework for states and utilities that want to advance integration of resilience and distribution planning processes to improve planning efficiency, better prioritize cost-effective grid expenditures, and balance planning objectives. The framework includes 7 key integration points between these planning processes: -Strategy process -Data -Threat assessments -Solution identification and prioritization -Optimization opportunities -Consideration of other grid needs -Metrics Lawrence Berkeley National Laboratory reviewed utility distribution system plans and interviewed subject matter experts to identify emerging practices for each of the 7 integration points. This report presents these practices, which can be used as a guide toward more holistic planning and cohesive investment strategies. It also includes 3 case studies to provide practical examples of how utilities apply such integrated planning processes: two pole hardening programs and one microgrid planning effort. The report concludes by identifying opportunities for future research.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A virtual Frisch-grid geometry-based CZT gamma detector for in-field radioisotope identification

Here, we present a Virtual Frisch-Grid geometry-based CZT gamma detector developed for identifying different radioisotopes over an energy range from a few keV up to 2 MeV, and useful for efficient characterization of CZT crystals. The detector is built with a 3 x 3 matrix of CZT crystals, each measuring approximately 6 mm x 6 mm x 15 mm. The charge generated within the sensor’s active volume is read out via an anode connected directly to the AVG3_Dev integrated circuit. A current signal induced by charge drift is collected on side pads of the crystals, enabling reconstruction of a 3D interaction position. This paper discusses the design, development, and performance of the standalone, mobile detector system, which integrates the AVG3_Dev readout IC developed at Brookhaven National Laboratory, a high-speed FPGA-based with per-channel digital signal processing, and embedded system capabilities. The device is compact, battery-powered, and supports wireless data streaming, making it suitable for field operations for radioisotope identification.

47 OTHER INSTRUMENTATION↗

Coupled Induction Machine and HVAC Models for Simulating HVAC Performance Considering Grid Dynamics in Buildings

This paper presents the development of novel models that integrate induction machines with HVAC equipment, such as pumps, heat pumps, and chillers, to analyze the impact of electrical parameters on the operational performance of thermo-fluid systems. The proposed model employs a coupling technique that captures the dynamic interactions between induction machines and HVAC systems. By integrating electrical, thermal, and mechanical dynamics, the models provide a comprehensive framework for simulating real-world scenarios, including interactions with the electrical grid. This achievement was made possible through the development of a Computationally Efficient and Accurate Induction Machine (CEAIM) model. Implemented using the equation-based Modelica language, the CEAIM model has been validated against experimental results, manufacturer data sheets, and various operating conditions. Its performance has been compared with existing induction machine models in the Modelica Standard Library (MSL), demonstrating superior accuracy and computational efficiency. The CEAIM model predicts torque, speed, and power consumption with a coefficient of determination (R 2 ) ranging from 0.98 to 1 and a coefficient of variation of root mean square error (CVRMSE) between 0.27% and 6.67%. Additionally, CEAIM scales more efficiently than conventional MSL models, with a slower computational growth rate in large-scale simulations. After thorough validation of the CEAIM model, it was coupled with HVAC equipment as this approach provides a detailed multi-dimensional view of capturing electrical transients and mechanical performance. To support this, a case study was conducted to showcase its capabilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FNCL Enhancements Implementation (FY25 Annual Report)

The FNCL investigations team at Lawrence Livermore National Laboratory (LLNL) has completed research and development of hardware, signal processing, and analysis tools to enhance the measurement capabilities of both the current CAEN SyS VeryFuel Fast Neutron Collar (FNCL) instrument and a next-generation FNCL prototype. The team successfully built and commissioned the LLNL Demonstrator System: a fully integrated, three-panel detector system featuring higher segmentation, plastic scintillators (EJ-276D), Silicon Photomultipliers (SiPMs), no high-voltage requirement, a reduced electronic footprint, and the LLNL-developed Gaussian Mixture Model Pulse Shape Discrimination (GMM-PSD) signal processing. An extensive experimental campaign was conducted at LLNL’s Inherently Safe Subcritical Assembly (ISSA) facility using both the baseline FNCL and the LLNL Demonstrator. The campaign results validated system performance, calibration stability, and the effectiveness of advanced signal processing and analysis algorithms in a relevant environment.

and physical protection↗

Disorder Enhanced Thermalization in Interacting Many-Particle System

We introduce an extension of the non-equilibrium dynamical mean field theory to incorporate the effects of static random disorder in the dynamics of a many-particle system by integrating out different disorder configurations resulting in an effective time-dependent density-density interaction. We use this method to study the non-equilibrium transient dynamics of a system described by the Fermi Anderson-Hubbard model following an interaction and disorder quench. The method recovers the solution of the disorder-free case for which the system exhibits qualitatively distinct dynamical behaviors in the weak-coupling (prethermalization) and strong-coupling regimes (collapse-and-revival oscillations). However, we find that weak random disorder promotes thermalization. In the weak coupling regime, the jump in the quasiparticle weight in the prethermal regime is suppressed by random disorder while in the strong-coupling regime, random disorder reduces the amplitude of the quasiparticle weight oscillations. These results highlight the importance of disorder in the dynamics of realistic many-particle systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

FARM supervisory capabilities for thermal energy storage

The FARM (Feasible Actuator Range Modifier) module is a component of the RAVEN-based FORCE framework for the analysis of Integrated Energy Systems (IES). FARM aids HERON in the solution of the power dispatch problem by evaluating feasible set-point signals to be issued to the control systems of the different IES unit components. Set-points need to satisfy limits on both production variables (i.e., the variables to be optimized such as the electrical power, etc.) and process variables tied to the service life of equipment (e.g., steam flowrate, vessel pressure, turbine firing temperature, etc.). To enforce all these limits, a two-stage approach is adopted. First, the power dispatcher algorithm in HERON module estimates set-points that meet the constraints on the production variables, e.g., power levels and power ramp rate limits. These constraints are called explicit constraints. Then, if necessary, FARM adjusts these set-points to ensure the respect of the limits on the process variables of interest, given the knowledge of the system dynamics acquired through machine learning algorithms. These constraints are called implicit constraints. From this standpoint, FARM constitutes a bridge between the HERON power dispatcher that adopts a simplified description of the IES unit (low-resolution physics) and the HYBRID high-fidelity models (high-resolution physics). In this report, an overview of the major capabilities of the latest release of FARM is provided, along with a summary of the tool demonstration campaign conducted at the Dynamic Energy Technology and Integration Laboratory (DETAIL) facility. These results assess the performance of the control system architecture embedding FARM both as a Validator of the HERON power dispatcher and as a real time Supervisory control scheme. Additionally, the report outlines the areas that FARM might benefit from, along with proposed solutions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sub-2 Kelvin Characterization of Nitrogen-Vacancy Centers in Silicon Carbide Nanopillars

The development of efficient quantum communication technologies depends on the innovation in multiple layers of its implementation, a challenge we address from the fundamental properties of the physical system at the nanoscale to the instrumentation level at the macroscale. We select a promising near-infrared quantum emitter, the nitrogen-vacancy (NV) center in 4H-SiC, and integrate it, at an ensemble level, with nanopillar structures that enhance photon collection efficiency into an objective lens. Moreover, changes in collection efficiency in pillars compared to bulk can serve as indicators of color center orientation in the lattice. To characterize NV center properties at the unprecedented sub-2 K temperatures, we incorporate compatible superconducting nanowire single photon detectors inside the chamber of an optical cryostat and create the ICECAP, the Integrated Cryogenic system for Emission, Collection And Photon detection. ICECAP measurements show no significant line-width broadening of NV ensemble emission and up to 14-fold enhancement in collected emission. With additional filtering, we measure emitter lifetimes of NV centers in a basal ( hk ) and axial ( kk ) orientation, unveiling their cryogenic values of 2.2 and 2.8 ns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Equipment List Comparing Balance of Plant Containing a Heat Pump against a Reference Electricity Generating Plant

Approximately two-thirds of U.S. energy consumption in the industrial and transportation sectors relies on fossil fuels. These sectors require high-quality heat, i.e., thermal energy at very high temperatures, for molecular transformation processes. The Integrated Energy Systems (IES) program aims to assess the economic potential of utilizing nuclear-grade heat from Advanced Reactors (ARs) to meet the high-quality heat demands. By having industrial processes (IPs) supplied with nuclear-generated heat, manufacturers could benefit from more stable and potentially lower energy costs, reducing reliance on volatile fossil fuel markets. The main outcome of the FY24 research was the thermodynamic assessment and gap analysis of steam generation for IP applications. The study completed in June 2024 demonstrated that the required steam temperatures could be achieved by integrating a heat pump into an AR power plant. After identifying the thermal demands of target IPs, multiple balance of plant configurations for the Xe-100 reactor by X-energy, incorporating a heat pump, were analyzed. Their technical feasibilities were assessed, including the design of suitable axial compressors for these applications. Comparative performance analysis showed that thermal efficiency alone is insufficient to evaluate system suitability. To address this, a new indicator (heat factor) was introduced in the report released in September 2024 to quantify the low-quality thermal power needed to produce one unit of high-quality heat for the IP. Results showed that integrating heat pumps into Rankine cycles enables higher steam temperatures, though at the expense of increased thermal energy input. This report builds upon and completes the foundational work previously undertaken. It focuses on the design of two Balance of Plant (BOP) configurations, both based on Rankine energy conversion cycles: “Case 1”, which involves electricity generation only, and “Case 2”, which combines electricity and high-temperature heat generation for industrial use. For each configuration, a comprehensive equipment list was developed, detailing all major components such as turbines, compressors, heat exchangers, pumps, and control systems. These lists will serve as the basis for future comparative cost analyses, with the goal of assessing the number and type of components required to integrate a heat pump into the Rankine cycle and to establish a heat transport system capable of delivering thermal energy from the nuclear plant to an industrial facility. Using the constitutive equations presented in the June 2024 milestone, the operating conditions of all BOP components for both “Case 1” and “Case 2” were evaluated. These parameters—such as temperature, pressure, mass flow rate, and steam quality—served as the basis for calculating the associated thermal and mechanical power flows. The net power required from the heat pump to raise the steam temperature to the target level was also determined. The thermodynamic performance of the configuration was then assessed using the heat factor metric. The key outcome of this analysis is a comparative table that presents the equipment that was used in the “Case 1” and “Case 2” configurations. This study offers a preliminary comparison of the two designs, providing insight into the impact of integrating a heat pump in terms of component requirements and thermal efficiency. This equipment list, together with the evaluated operating conditions, also serves as a foundation for the economic analyses scheduled for the current fiscal year.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Detection and imaging of chemicals and hidden explosives using terahertz time-domain spectroscopy and deep learning

Detecting concealed chemicals and explosives remains a critical challenge in global security. Terahertz time-domain spectroscopy (THz-TDS) offers a promising non-invasive and stand-off detection technique owing to its ability to penetrate optically opaque materials without causing ionization damage. While many chemicals exhibit distinct spectral features in the terahertz range, conventional terahertz-based detection methods often struggle in real-world environments, where variations in sample geometry, thickness, and packaging can lead to inconsistent spectral responses. In this study, we present a chemical imaging system that integrates THz-TDS with deep learning to enable accurate pixel-level identification and classification of different explosives. Operating in reflection mode and enhanced with plasmonic nanoantenna arrays, our THz-TDS system achieves a peak dynamic range of 96 dB and a detection bandwidth of 4.5 THz, supporting practical, stand-off operation. By analyzing individual time-domain pulses with deep neural networks, the system exhibits strong resilience to environmental variations and sample inconsistencies. Blind testing across eight chemicals—including pharmaceutical excipients and explosive compounds—resulted in an average classification accuracy of 99.42% at the pixel level. Notably, the system maintained an average accuracy of 88.83% when detecting explosives concealed under opaque paper coverings, demonstrating its robust generalization capability. These results highlight the potential of combining advanced terahertz spectroscopy with neural networks for highly sensitive and specific chemical and explosive detection in diverse and operationally relevant scenarios.

Imaging and sensing↗

Next generation retrofit wall panels with integrated vacuum insulation panels

Approximately two-thirds of residential buildings in the United States were constructed before the Department of Energy established energy conservation measures. These buildings present major opportunities for improving energy efficiency, though retrofitting them remains technically and economically challenging. This study presents the development and the durability evaluation of an innovative retrofit panel system that integrates vacuum insulation panels (VIP) with a nail-base panel (called a retrofit insulated panel) to enhance thermal performance with minimal disruption to occupants and without altering standard nail-based panel installation practices. Hygrothermal simulations were conducted to assess the moisture behavior of wall assemblies before and after retrofit installation under varying water vapor control strategies and climate conditions. Results indicate that, with appropriate moisture control strategy, the retrofit system effectively prevents moisture accumulation, keeping mold index values and relative humidity levels below critical thresholds. Additionally, Guarded Hot Box testing was performed to compute the effective R-value of the panel under different coverage areas that demonstrates its effectiveness in enhancing both thermal and moisture performance in existing residential buildings.

Iffa, Emishaw [ORNL]↗

Integration of Solid Oxide Fuel Cell Systems Into Artificial Intelligence Data Centers

This report presents the results of a techno-economic analysis (TEA) that evaluates the economic benefits of integrating solid oxide fuel cell (SOFC) systems with artificial intelligence (AI) data centers. The analysis was completed in two phases: a scoping-level analysis was performed to identify impactful integration opportunities, followed by a more detailed TEA. Results show that, due to their modularity, SOFC can meet the 99.999% availability requirement of data centers with minimal additional costs. Heat integration via absorption chillers decreases data center electricity consumption at the tradeoff of increased water consumption. Higher SOFC exhaust temperatures are important for achieving larger electricity savings. Finally, power electronics integration with SOFC direct current electricity can reduce electricity consumption by 9 percent and reduce water consumption by 6.4 percent.

20 FOSSIL-FUELED POWER PLANTS↗

Automated Operational Forecasting of Monsoon Low Pressure Systems

Monsoon low pressure systems (LPSs) are the dominant rain-bearing weather system of South Asia, often producing extreme precipitation and hydrological disasters in a region inhabited by nearly two billion people. Despite the importance of these storms, no operational system has automatically identified and tracked LPS in real time in numerical weather prediction model output; many commonly used vortex-tracking algorithms are ill suited for monsoon LPS because of the weak winds and cold cores of these systems. Here, we describe a new system that uses optimized algorithms to identify monsoon LPS in short- to medium-range forecasts from the U.S. Global Ensemble Forecast System (GEFS) and a version of the deterministic Global Forecast System (GFS) adapted and used operationally by the Indian Institute of Tropical Meteorology (IITM). We also assess the historical performance of these models in forecasting South Asian monsoon LPS, comparing this with the performance of the Integrated Forecasting System of the ECMWF. We assess the accuracy of model predictions of LPS genesis, position, intensity, and precipitation rates for forecast lead times of 1–5 days, yielding quantitative information on model biases to guide operational forecasters and disaster managers. The system we introduce here could be extended to other low-latitude regions affected by dynamically weak, heavily precipitating atmospheric vortices that are often not included in tropical cyclone inventories.

54 ENVIRONMENTAL SCIENCES↗

Heat Pipe Enhanced Thermal Management System for GaN Switches in an Integrated Modular Motor Drive for Aircraft Propulsion

This paper presents the process of sizing a heat pipe enhanced thermal management system (TMS) for GaN switches in an integrated modular motor drive (IMMD) powering a 250 kW aircraft propulsion electric motor. A test setup mimicking the TMS and GaN switches assembly is constructed. The condenser chamber of the TMS is modeled in ANSYS Fluent while the GaN switches assembly is modeled in ANSYS Thermal allowing us to verify heat spreader temperature under test conditions and estimate GaN temperatures under test and actual application operating conditions.

DIRECT ENERGY CONVERSION↗

Advances in Modeling Capabilities for Critical Mineral Separation Technologies: A PrOMMiS Overview

This is an oral presentation at the TechConnect conference on the work developed by PrOMMiS. PrOMMiS builds on and extends capabilities developed within the Department of Energy’s (DOE) Institute for the Design of Advanced Energy Systems (IDAES), Integrated Platform, and Water Treatment Technoeconomic Assessment Platform (WaterTAP), which have been successfully leveraged by other Department of Energy research areas. The open-source toolkit facilitates validation, reproducibility, and accountability, allowing for easy extension of the framework to other systems. This talk presents an overview of the PrOMMiS capabilities, including unit model library, advances in thermophysical properties models, and capital cost libraries for simulation and optimization of mineral processing technologies. The PrOMMiS applications include (1) conceptual design and superstructure optimization for screening different process configurations and identifying promising technologies; (2) dynamic modeling and optimization to enable the creation of digital twins; (3) surrogate modeling tools to leverage data when predictive thermodynamic models are not currently available; (4) technical risk reduction via uncertainty quantification and robust optimization to identify process designs that are robust to process variability and uncertainties; and (5) deployment of uncertainty quantification tools to maximize knowledge gained from experimental campaigns, while reducing the number of experiments required

critical minerals and materials↗

Small Hydro Power Plants with Integrated BESS for Enhance Resiliency

Battery energy storage systems (BESS) are an important asset for power systems with high integration levels of renewable energy, and they can be controlled to provide various services to the grid. This paper presents the hardware demonstration and characterization of using a utility-scale BESS with grid-following (GFL) and grid-forming (GFM) controls and a run-of-river (ROR) hydropower plant to perform a bottom-up power system black start that enhances power systems' resiliency. ROR hydropower plants are generally not used for power system restoration due to their frequency instability during islanded operation; however, BESS with droop control can provide critical damping to convert a ROR hydropower generator into a black start- capable unit. To demonstrate this, we carry out hardware experiments at the megawatt-scale integrating a synchronous generator driven by a dynamometer, an actual GFL/GFM BESS, a medium-voltage impedance network, and a load bank. The demonstration shows the different roles of BESS with GFL and GFM control in power system restoration. GFL BESS can suffer from high-frequency oscillations, even instability, depending on the droop control gain and loading condition. The results provide further insights for system operators on how GFL- or GFM controlled BESS can enhance grid stability and how hydro-BESS hybrids can operate as a black-start-capable unit. The presented experimental results are also a valuable resource to understand the different stability characteristics of real-world BESS with different control modes.

24 POWER TRANSMISSION AND DISTRIBUTION↗