An experimental setup for the simultaneous measurement of thermoelectric power of two samples from 77 K to 500 K

We report on an experimental setup for the simultaneous measurement of the thermoelectric power (TEP) of two samples in the temperature range from 77 K to 500 K using optimum electronic instruments. The setup consists of two rectangular copper bars in a bridge arrangement for sample mounting, two surface mount (SM) chip resistors for creating alternate temperature gradient, and a type E thermocouple in differential geometry for gradient temperature (ΔT) measurement across the samples. In addition, a diode arrangement has been made for the alternate heating of SM resistors using only one DC current source. The measurement accuracy of ΔT increases with the differential thermocouple arrangement. For the calibration of the setup, measurements of TEP on a high purity (99.99%) platinum wire and type K thermocouple wires Chromel and Alumel have been performed from 77 K to 500 K with respect to copper lead wires. Additionally, this setup can be utilized to calibrate an unknown sample against a sample of known absolute TEP.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Small-scale cook-off experiments and models of ammonium nitrate

Here, we have completed a series of small-scale cook-off experiments of ammonium nitrate (AN) prills in our Sandia Instrumented Thermal Ignition test at nominal packing densities of about 0.8 g/cm 3 . We increased the boundary temperature of our aluminum confinement cylinder from room temperature to a prescribed set-point temperature in 10 min. Our set-point temperature ranged from 508 to 538 K. The external temperature of the confining cylinder was held at the set-point temperature until ignition. We used type K thermocouples to measure temperatures associated with several polymorphic phase changes as well as melting and boiling. As the AN boiled, our thermocouples were destroyed by corrosion, which may have been caused by reaction of hot nitric acid (HNO 3 ) with nickel to form nickel nitrate, Ni(NO 3 ) 2 . Videos of the corroding thermocouples showed a green solution that was similar to the color of Ni(NO 3 ) 2 . We found that ignition was imminent as the AN boiling point was exceeded. Ignition of the AN prills was modeled by solving the energy equation with an energy source due to desorption of moisture and decomposition of AN to form equilibrium products. A Boussinesq approximation was used in conjunction with the momentum equation to model flow of the liquid AN. We found that the prediction of ignition was not sensitive to small perturbations in the latent enthalpies.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

OECD MCCI project enhancing instrumentation for reactor materials experiments, Rev. 0 September 3, 2002.

Reactor safety experiments for studying the reactions of a molten core (corium) with water and/or concrete involve materials at extremely high temperature. Such high temperature severely restricts the types of sensors that can be employed to measure characteristics of the corium itself. Yet there is great interest in improving instrumentation so that the state of the melt can be established with more precision. In particular, it would be beneficial to increase both the upper range limit and accuracy of temperature measurements. The poor durability of thermocouples at high temperature is also an important issue. For experiments involving a water-quenched melt, direct measurements of the growth rate of the crust separating the melt and water would be of great interest. This is a key element in determining the nature of heat transfer between the melt and coolant. Despite its importance, no one has been able to directly measure the crust thickness during such tests. This paper considers three specialized sensors that could be introduced to enhance melt characterization: (1) A commercially fabricated, single point infrared temperature measurement with the footprint of a thermowell. A lens assembly and fiber optic cable linked to a receiver and amplifier measures the temperature at the base of a tungsten thermowell. The upper range limit is 3000 C and accuracy is {+-}0.25% of the reading. (2) In-house development of an ultrasonic temperature sensor that would provide multipoint measurements at temperatures up to {approx}3000 C. The sensors are constructed from tungsten rods and have a high temperature durability that is superior to that of thermocouples. (3) In-house development of an ultrasonic probe to measure the growth rate of the corium crust. This ultrasonic sensor would include a tungsten waveguide that transmits ultrasonic pulses up through the corium melt towards the crust and detects reflections from the melt/crust interface. A measurement of the echo time delay would provide the location of the interface. These three sensors would provide a considerable upgrade of the instrumentation used in our reactor materials tests. The infracouple is a commercial product that could provide an immediate improvement in temperature measurements. The sensor could also serve to corroborate thermocouple data by providing a measurement based upon a different physical principle. The ultrasonic temperature sensor would involve a greater investment and longer time frame than the infracouple, but offers all the advantages of the infracouple along with miniaturization and the ability to measure at multiple locations. In addition, the UTS is the platform from which we would begin development of the crust detector. Of the three sensors, the crust detector requires the most effort and entails the greatest uncertainty. However, a real-time crust thickness measurement has never before been made and such data would be unique and of great benefit to reactor materials experiments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

HBU R and D Cask Transportation Options - 20436

The TN-32B HBU Demonstration Cask was successfully loaded in November 2017 with 32 high burnup (HBU) fuel assemblies at Dominion's North Anna Nuclear Plant and is collecting thermal data as intended. The first two phases of this very successful project sponsored by DOE and EPRI was designed to collect thermal data of HBU fuel to support extended storage. The next phase of the project requires the cask be licensed for transportation so the cask can be relocated to a site (to be determined by DOE) to facilitate long term monitoring and additional research on the fuel. This is a unique challenge given the constraints that exist for this particular bolted metal cask. The TN-32B cask is a 234,288 lb. (storage configuration) dry storage system that was selected for this project and it was modified to provide thermal data and the ability to collect gas samples after loading. Several major issues must be addressed to obtain the transport license including protecting the seven lid penetrations that were made to allow for the insertion of the thermocouples into the selected fuel assemblies after the cask was loaded. In order to protect the integrity of the research, the payload must remain as is. Therefore, the cask system must be placed into the transportation configuration without rewetting the fuel, replacing the lid and without removing the thermocouple instrumentation that is currently installed. A critical portion of the design and engineering that was performed in the first two phases of the project was to ensure that future transportation of the cask was integrated into the approach. Efforts were made to accommodate requirements such as containment boundary leakage testing, installation of impact limiter brackets and lid bolts suitable for transportation. Due to the science requirements of the project, the fuel selected was intended to yield the highest payload temperatures permitted to provide the greatest value for the researchers. This resulted in higher than usual external dose rates and surface temperatures that warranted performing as much preparatory work prior to cask loading to ensure ALARA and personnel safety to the greatest extent practical rather than working on a loaded cask. In addition to the work performed prior to cask load, there are remaining challenges such as protecting the modified lid, design and fabrication of impact limiters that accommodate the modified cask lid and preserving the thermocouple connections for continued monitoring. The project team is currently performing the necessary calculations, engineering, and design to support the licensing as required by the US NRC. Pre-application meetings have been held to inform the regulator of the planned technical approach to ensure compliance with the applicable regulations. The current plan is to obtain the transportation C of C by the end of 2021. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Statistical Analysis Techniques to Support the NGNP Fuel Performance Experiments

This paper describes the development and application of statistical analysis techniques to support the AGR experimental program on NGNP fuel performance. The experiments conducted in the Idaho National Laboratory’s Advanced Test Reactor employ fuel compacts placed in a graphite cylinder shrouded by a steel capsule. The tests are instrumented with thermocouples embedded in graphite blocks and the target quantity (fuel/graphite temperature) is regulated by the He-Ne gas mixture that fills the gap volume. Three techniques for statistical analysis, namely control charting, correlation analysis, and regression analysis, are implemented in the SAS-based NGNP Data Management and Analysis System (NDMAS) for automated processing and qualification of the AGR measured data. The NDMAS also stores daily neutronic (power) and thermal (heat transfer) code simulation results along with the measurement data, allowing for their combined use and comparative scrutiny. The ultimate objective of this work includes (a) a multi-faceted system for data monitoring and data accuracy testing, (b) identification of possible modes of diagnostics deterioration and changes in experimental conditions, (c) qualification of data for use in code validation, and (d) identification and use of data trends to support effective control of test conditions with respect to the test target. Analysis results and examples given in the paper show the three statistical analysis techniques providing a complementary capability to warn of thermocouple failures. It also suggests that the regression analysis models relating calculated fuel temperatures and thermocouple readings can enable online regulation of experimental parameters (i.e. gas mixture content), to effectively maintain the target quantity (fuel temperature) within a given range.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Considerations for the temperature stratification in a pre-burn constant-volume combustion chamber

In recent years, the Engine Combustion Network (ECN) has developed as a worldwide reference for understanding and describing engine combustion processes, successfully bringing together experimental and numerical efforts. Since experiments and numerical simulations both target the same boundary conditions, an accurate characterization of the stratified environment that is inevitably present in experimental facilities is required. The difference between the core-, and pressure-derived bulk-temperature of pre-burn combustion vessels has been addressed in various previous publications. Additionally, thermocouple measurements have provided initial data on the boundary layer close to the injector nozzle, showing a transition to reduced ambient temperatures. The conditions at the start of fuel injection influence physicochemical properties of a fuel spray, including near nozzle mixing, heat release computations, and combustion parameters. To address the temperature stratification in more detail, thermocouple measurements at larger distances from the spray axis have been conducted. Both the temperature field prior to the pre-combustion event that preconditions the high-temperature, high-pressure ambient, as well as the stratification at the moment of fuel injection were studied. To reveal the cold boundary layer near the injector with a better spatial resolution, Rayleigh scattering experiments and thermocouple measurements at various distances close to the nozzle have been carried out. The impact of the boundary layers and temperature stratification are illustrated and quantified using numerical simulations at Spray A conditions. Next to a reference simulation with a uniform temperature field, six different stratified temperature distributions have been generated. These distributions were based on the mean experimental temperature superimposed by a randomized variance, again derived from the experiments. The results showed that an asymmetric flame structure arises in the computed results when the temperature stratification input is used. In these predictions, first-stage ignition is advanced by 24 $\mu$s , while second-stage ignition is delayed by 11 $\mu$s. At the same time a lift-off length difference between the top and the bottom of up to 1.1 mm is observed. Furthermore, the lift-off length is less stable over time. Given the shown dependency, the temperature data is made available along with the vessel geometry data as a recommended basis for future numerical simulations.

42 ENGINEERING↗

Atomic Layer Thermopiles: Comprehensive static calibration, comparison and application in subsonic and supersonic flows

Here, this paper compares the calibration of different heat flux sensors in radiation- and convection-based sub- and supersonic operation. First, four heat flux sensors based on different principles: ALTP (Transverse Seebeck Effect), HFM-8E (differential-layer device), coaxial Thermocouple and a TG-2000 (circular-foil gage) are calibrated in a laser-based radiation setup. In a second step, all heat flux sensors are compared with a slug-calorimeter within a subsonic convection-dominated facility based on stagnation-point measurements of an impinging hot air jet. The obtained results indicate that a sensitivity transfer between a radiative calibrated sensor used in a mainly convective environment is not always possible and can lead to significant, systematic errors. Calibration in a subsonic shear flow with thermocouple readings demonstrate small divergence from the manufacturer provided sensitivity. Finally, supersonic testing with high frequency shock-boundary layer interactions highlight the need for ALTP rather than the conventional use of thermocouple arrays to resolve the high frequency phenomena associated with shock boundary layer interactions.

42 ENGINEERING↗

The statistical analysis techniques to support the NGNP fuel performance experiments

This paper describes the development and application of statistical analysis techniques to support the Advanced Gas Reactor (AGR) experimental program on Next Generation Nuclear Plant (NGNP) fuel performance. The experiments conducted in the Idaho National Laboratory’s Advanced Test Reactor employ fuel compacts placed in a graphite cylinder shrouded by a steel capsule. The tests are instrumented with thermocouples embedded in graphite blocks and the target quantity (fuel temperature) is regulated by the He–Ne gas mixture that fills the gap volume. Three techniques for statistical analysis, namely control charting, correlation analysis, and regression analysis, are implemented in the NGNP Data Management and Analysis System for automated processing and qualification of the AGR measured data. The neutronic and thermal code simulation results are used for comparative scrutiny. The ultimate objective of this work includes (a) a multi-faceted system for data monitoring and data accuracy testing, (b) identification of possible modes of diagnostics deterioration and changes in experimental conditions, (c) qualification of data for use in code validation, and (d) identification and use of data trends to support effective control of test conditions with respect to the test target. Analysis results and examples given in the paper show the three statistical analysis techniques providing a complementary capability to warn of thermocouple failures. It also suggests that the regression analysis models relating calculated fuel temperatures and thermocouple readings can enable online regulation of experimental parameters (i.e. gas mixture content), to effectively maintain the fuel temperature within a given range.

99 GENERAL AND MISCELLANEOUS↗

Integrated plasma facing component calorimetry for measurement of shot integrated deposited energy in the NSTX-U

Here, the upgrade to the National Spherical Torus eXperiment (NSTX-U) increases the injected neutral beam power up to 12 MW and the plasma current up to I p = 2 MA for plasma durations up to 5 s. The graphite plasma facing components have been re-designed to handle greater heat and energy fluxes than were seen in NSTX using a castellated design. We present the experimental testing and validation of a castellated graphite target, similar to the prototype tile design, instrumented with thermocouples at various depths in the castellation. During testing, incident heat flux is provided by a programmed electron beam system and surface temperatures are measured via infrared thermography directly viewing the target surface. It was found that the thermocouple response scaled linearly with the measured surface temperature rise regardless of thermocouple depth in the castellation. A sensitivity of 14.3 °C/kJ of deposited energy was found when treating individual castellations as a semi-infinite solid.

47 OTHER INSTRUMENTATION↗

Validation of 266 nm UV Raman thermometry using the alpha-to-beta quartz transition

Ultraviolet Raman scattering is a promising diagnostic for temperature measurements relevant to dynamic compression experiments, where improved signal strength and reduced background are critical. In this work, we experimentally validate Raman thermometry at 266 nm using crystalline quartz heated through the α to β phase transition in a tube furnace. Quartz provides a useful benchmark because of its well-characterized transition temperature near 846 K at ambient pressure. Temperatures inferred from the Stokes to anti-Stokes intensity ratio are compared with thermocouple measurements and with the observed phase transition. Single-shot Raman temperatures track the thermocouple closely, with an empirical single-shot scatter of approximately ±15 K under the present conditions. Temporal averaging reduces shot-to-shot scatter and improves agreement between the Raman temperatures and thermocouple readings to within approximately 8 K, while the transition is identified within 5 K of the accepted value. Measurements are performed using the fourth harmonic of a nanosecond pulsed Nd:YAG laser at 266 nm. The shorter excitation wavelength provides enhanced Raman scattering efficiency and reduced visible background relative to conventional visible excitation. Comparison with 532 nm Raman measurements acquired in the same experimental geometry demonstrates substantially improved signal-to-noise ratio for the UV configuration. These results establish 266 nm Raman thermometry as a reliable and accurate temperature diagnostic under controlled heating conditions and provide a quantitative benchmark for future application in dynamic compression and shock physics experiments.

Chemistry - Chemical explosives↗

Thermal modeling of directed energy deposition additive manufacturing using graph theory

Purpose: The purpose of this paper is to develop, apply and validate a mesh-free graph theory–based approach for rapid thermal modeling of the directed energy deposition (DED) additive manufacturing (AM) process. Design/methodology/approach: Here, the authors develop a novel mesh-free graph theory–based approach to predict the thermal history of the DED process. Subsequently, the authors validated the graph theory predicted temperature trends using experimental temperature data for DED of titanium alloy parts (Ti-6Al-4V). Temperature trends were tracked by embedding thermocouples in the substrate. The DED process was simulated using the graph theory approach, and the thermal history predictions were validated based on the data from the thermocouples. Findings: The temperature trends predicted by the graph theory approach have mean absolute percentage error of approximately 11% and root mean square error of 23°C when compared to the experimental data. Moreover, the graph theory simulation was obtained within 4 min using desktop computing resources, which is less than the build time of 25 min. By comparison, a finite element–based model required 136 min to converge to similar level of error. Research limitations/implications: This study uses data from fixed thermocouples when printing thin-wall DED parts. In the future, the authors will incorporate infrared thermal camera data from large parts. Practical implications: The DED process is particularly valuable for near-net shape manufacturing, repair and remanufacturing applications. However, DED parts are often afflicted with flaws, such as cracking and distortion. In DED, flaw formation is largely governed by the intensity and spatial distribution of heat in the part during the process, often referred to as the thermal history. Accordingly, fast and accurate thermal models to predict the thermal history are necessary to understand and preclude flaw formation. Originality/value: This paper presents a new mesh-free computational thermal modeling approach based on graph theory (network science) and applies it to DED. The approach eschews the tedious and computationally demanding meshing aspect of finite element modeling and allows rapid simulation of the thermal history in additive manufacturing. Although the graph theory has been applied to thermal modeling of laser powder bed fusion (LPBF), there are distinct phenomenological differences between DED and LPBF that necessitate substantial modifications to the graph theory approach.

42 ENGINEERING↗

Leaf temperature raw data, 2015 - 2017, at Manaus, Brazil

This data package contains raw leaf surface temperature data from the NGEE Tropics K34 tower site on a plateau near Manaus, Brazil, including automated and manually collected time series data on leaf surface temperature (thermocouples, IR radiometer, thermocamera). Leaf surface temperature (LST) was determined throughout diurnal periods using individual type T thermocouples (Omega Engineering) on 8 individual leaves of a single tree. Mature leaves at the same height and general area near the tower were selected. LST measurements were taken every 15 s and recorded on a field portable self-powered data logger (OM-CP-OCTTEMP-A, Omega Engineering). Measurements were stopped in the case of a storm or rain which can remove the attached thermocouple wires from the leaf due to large wind-driven branch movements. Included in the attached zip file are six folders: three with LST data in Excel and CSV file formats from both the K34 and B34 towers, one folder with data logger configuration programs that were used for data collection, a fifth folder with PDF files of manuals for instruments used and a final folder with two Excel metadata files. See dataset references for associated metadata package. This dataset replaces the leaf surface temperature data of two retired packages, http://dx.doi.org/10.15486/ngt/1507764 and http://dx.doi.org/10.15486/ngt/1507767

54 ENVIRONMENTAL SCIENCES↗

AGR-2 Data Qualification Report for ATR Cycles 149B, 150A, 150B, 151A, and 151B

This report provides the data qualification status of AGR-2 fuel irradiation experimental data from Advanced Test Reactor (ATR) cycles 149B, 150A, 150B, 151A, and 151B), as recorded in the Nuclear Data Management and Analysis System (NDMAS). The AGR-2 data streams addressed include thermocouple temperatures, sweep gas data (flow rate, pressure, and moisture content), and fission product monitoring system (FPMS) data for each of the six capsules in the experiment. A total of 3,307,500 5-minute thermocouple and sweep gas data records were received and processed by NDMAS for this period. There are no AGR-2 data for cycle 150A because the experiment was removed from the reactor. Of these data, 82.2% were determined to be Qualified based on NDMAS accuracy testing and data validity assessment. There were 450,557 Failed temperature records due to thermocouple failures, and 138,528 Failed gas flow records due to gas flow cross-talk and leakage problems that occurred in the capsules after cycle 150A. For FPMS data, NDMAS received and processed preliminary release rate and release-to-birth rate ratio (R/B) data for the first three reactor cycles (cycles 149B, 150B, and 151B). This data consists of 45,983 release rate records and 45,235 R/B records for the 12 radionuclides reported. The qualification status of these FPMS data has been set to In Process until receipt of QA-approved data generator reports. All of the above data have been processed and tested using a SAS®-based enterprise application software system, stored in a secure Structured Query Language database, and made available on the NDMAS Web portal (http://ndmas.inl.gov) for both internal and external VHTR project participants.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Minimizing User Burden in Building Energy Analysis

Infrared (IR) imagery can provide valuable data to building energy auditors and the developers of Building Energy Models (BEM). IR by itself is not a panacea to the challenges facing energy auditors and modelers, but when combined with other techniques and Open Studio software, IR can play an important role in the minimization of the burden of creating building energy models and the diagnosing of building energy problems. While IR can be used to detect and quantify many aspects of a building’s thermal and energy performance, in Phase I we focused on a single capability: determining the R value of exterior walls. Two key attributes of using IR methods for R value determination is that IR methods measure the actual, installed performance in-situ – as opposed to relying on manufacturer or handbook values – and they can integrate performance over a wide area and thus can accurately account for thermal bridging and spatial anomalies such as “spotty” insulation installation. There is a trade between user burden and accuracy when using IR to determine a wall’s R value. The least burdensome approach is computing R values from a single IR snapshot. The most burdensome method we considered was to combine IR images with thermocouple and heat flux sensor (HFS) measurements made over the course of several days. The more effort users expend in making the measurements, the more accurate and robust the method becomes. Through a series of field tests at the ThermoAnalytics Inc. (TAI) HQ at Calumet, MI and a simulation of a 1980s era office building in Flagstaff, AZ we investigated methods to compute the R value of exterior walls using data from IR cameras, thermocouples and heat flux sensors. To compute R values the heat flux through the wall, along with temperatures on either side of the wall, must be known, modeled, or estimated – and the temperature difference through the wall should be at least 10 C. If only outdoor IR images are used in the method, the inside ambient air temperature must be estimated, and a simulation model created to predict heat fluxes and the indoor wall temperature. The accuracy of the resulting R value depends on the accuracy of the simulation and the assumptions it employs. Applying thermocouple sensors, either as iButtons or as part of a wireless sensor network, to the walls allows for the acquisition of temperatures over time. The longer the duration of the measurements, the more accurate and robust the method will be. Even with this level of measurement effort, modeling is still required to calculate the heat flux through the wall. The addition of a heat flux sensor alleviates the need for any modeling, and that results in improved accuracy. Driving the accuracy of the methods are several factors that can be quantified. How well are the wall surface temperatures known? Modeling the heat flux through walls requires knowing the details of the surrounding radiant environment and the heat transfer due to convection. How well are these boundary conditions known? Even when the heat flux is measured, error can arise when some of the measured heat is not conducted through the wall but rather goes into the thermal mass of the wall. Thermal mass effects occur when conditions and the heat flux values are fluctuating. A technique that is not robust will suffer in accuracy when these fluctuations occur. The R value determination method must be incorporated into the Open Studio process. In our proposed process, IR images and other measured sensor data are input into a module that would send R value estimates to a building library developed by team member Skidmore, Owings, & Merrill (SOM). This library of parameterized building models would use these R values along with information about the building’s age, type, and location to query the Open Studio BCL to identify the most likely constructions for walls, roof, and windows. Being based on the IMF feature of Energyplus, the SOM building library can quickly produce Energyplus models of buildings based on a limited number of user inputs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Small Volume Fuel Testers Report

Micro-liter fuel ignition testing (μ-FIT) is based on the premise that characteristics FREI (Flames with Repetitive Extinction and Ignition, i.e. cyclically occurring combustion events within heated capillaries), are linked to fuel properties. In early FY16, proof-of-concept measurements with primary reference fuel (PRF) mixtures, i.e. blends of n-heptane and iso-octane, yielded clear evidence for the feasibility of the approach. Our experiments showed that it is critical to accurately link observed flame positions to local temperatures, which provides information on ignition, extinction and flame propagation, all of which are known to be impacted by fuel properties. In FY16, one major hurdle was uncertainty of temperature calibration, which required significant efforts for corrective action that were not included in the original scope of work. Temperature calibrations are obtained by translating a thermocouple within the capillary in absence of a flame. While measurements have good repeatability when accounting for transient and insertion effects, results from nominally identical thermocouples reveal unacceptable uncertainty (up to ±50K), which is attributed to variations in thermocouple placement and manufacturing tolerances. This issue is currently being resolved by switching to non-intrusive optical temperature measurements. Updates are expected to yield uncertainties of less than ±10K, while also eliminating transient and insertion effects. The experimental work was complemented by computational efforts where it was shown that a simplified Lagrangian zero-D model with detailed kinetics yields fuelspecific differentiation of ignition temperatures for simple fuels that are consistent with experiments. Further, a 2D transient model was implemented in OpenFOAM to investigate combustion behavior of simple fuels at elevated pressure. In an upcoming visit to LLNL, more advanced simulations using LLNL’s computational tools (e.g. zero-RK) are planned, which will yield additional numerical insights on FREI behavior of more realistic spark ignited (SI) engine fuel surrogates. As there is a lag between DOE FY16 and the time frame of the LSU subcontract, it is anticipated that deliverables outlined in the scope of work will be met by the end of the subcontract (January 2017).

30 DIRECT ENERGY CONVERSION↗

An Instrumented Uranium Hemispherical Casting

This work describes an instrumented uranium casting experiment and the analysis of the results. The casting is a hemisphere with inner radius of 75 mm and wall thickness of 10 mm. Casting was performed in a multi-coil vacuum induction melting (VIM) furnace with separate induction power supplies for each coil. One coil was used to heat the crucible and melt the charge material. The second coil was used to heat the top of the mold in order to preheat the mold and obtain the desired initial mold temperature. The current, voltage, and frequency of the mold coil was measured during mold heating. The mold filling rate was measured by a load cell was placed under the mold stack. The thermal history of the casting was measured by 7 thermocouples in the casting cavity and 22 thermocouples imbedded in the graphite mold. Contact pins were also located in the mold to attempt to measure gap formation in the metal-mold interface. This instrumentation provides an in-depth thermal history of the mold heat-up, mold filling, solidification, and cool down. The thermocouples were positioned to allow for the casting/mold interfacial heat transfer coefficient to be determined as a function of position and time. The casting was sectioned and metallography and chemical analysis was performed.

36 MATERIALS SCIENCE↗

Demonstration of Embedded Sensors in Ceramic Structures

The Transformational Challenge Reactor (TCR) program seeks to demonstrate an advanced 3D printed nuclear reactor core. A binder jet additive manufacturing process is used to fabricate the complex SiC ceramic components of the TCR core. After printing, the components are densified via chemical vapor infiltration (CVI). This process allows complex cavities to be created in which sensors can be placed at strategic locations. Inserting the sensors during the CVI process allows the sensors to be embedded within the component as it is infiltrated. The primary challenge for embedding the sensors is identifying the sensors and sensor sheath materials that can survive the temperatures (>1,000°C) and chemical exposure to H 2 and HCl during CVI. The embedded sensors that are being investigated for use during TCR operation include thermocouples, self-powered neutron detectors, and spatially distributed fiber-optic temperature sensors. This report describes the CVI materials compatibility tests and initial trials for embedding functional sensors. Mo is identified as the most suitable sensor sheath material based on its availability in small diameter tubing, relatively low neutron absorption cross section, and compatibility with H 2 , HCl, and the surrounding SiC matrix at the process temperatures. Amorphous SiO2 fiber-optic samples with Au and Cu metal coatings were successfully embedded in SiC along with bare fibers, although the metal coatings showed some evidence of localized melting during CVI. Initial experiments attempting to embed functional sensors showed that the sensors can be embedded in 3D printed SiC parts, but there are still challenges that must be overcome to ensure that the sensors and sensor sheaths do not fail during CVI. In particular, Nb-sheathed Mo-Nb thermocouples failed at temperatures far lower than expected despite thermodynamic calculations and materials compatibility tests that show the Nb sheath to be compatible with the CVI environment. One potential explanation for the large expansion of the Nb sheath could be related to hydride formation in the lower temperature region of the sheath. Future work will focus on Mo-sheathed thermocouples instead of Nb. The fiberoptic sensors tested during the instrumented experiment broke due to the lack of mechanical protection after their polymer-based coatings were vaporized. Future instrumented experiments will use metal-coated optical fibers for strain sensing to provide additional mechanical protection. However, custom coatings with higher melting points than commercially available Au and Cu might be required. Regardless, fiber-optic sensors are still candidates for spatially distributed temperature measurements since they can be inserted into an embedded metal sheath after CVI.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Next-Gen RTG Peltier Cooling Testing [Poster]

The Peltier Cooling Test was developed and performed on a General Purpose Heat Source Radioisotope Thermoelectric Generator (GPHS-RTG) for the first time to support the refurbishment and recertification of a legacy flight unit. The GPHS-RTG flight units generate power for NASA space missions by converting heat from decaying Plutonium-238 into electricity using 572 thermocouples. The Peltier test successfully verified the electrical connections of the thermocouples by visually observing their thermal behavior under an applied current. Knowledge of the thermocouple electrical connections will be critical as the refurbishment and recertification plan moves forward.