Search NASA⌕ Search

SEARCH · Search NASA

Results for “TOF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Reaction mechanism and kinetics for N 2 reduction to ammonia on the Fe–Ru based dual-atom catalyst

Environmental and energy considerations demand that the Haber-Bosch process for reducing N 2 to NH 3 be replaced with electrochemical ammonia synthesis where the H atoms come from water instead of from H 2 . But a practical realization of electrochemical N 2 reduction reaction (NRR) requires the development of new generation electrocatalysts with low overpotential and high Faraday efficiency (FE). A major problem here is that the hydrogen evolution reaction (HER) competes with NRR. Herein, we consider new generation dual-site catalysts involving two different metals incorporated into a novel two-dimensional C 3 N–C 2 N heterostructure that provides a high concentration of well-defined but isolated active sites that bind two distinct metal atoms in a framework that facilitates electron transfer. We report here the mechanism and predicted kinetics as a function of applied potential for both NRR and HER for the (Fe–Ru)/C 3 N–C 2 N dual atom catalyst. These calculations employ the grand canonical potential kinetics (GCP-K) methodology to predict reaction free energies and reaction barriers as a function of applied potential. The rates are then used in a microkinetic model to predict the turn-over-frequencies (TOF) as a function of applied potential. At U = 0 V, the FE for NRR is 93%, but the current is only 2.0 mA cm –2 . The onset potential (at 10 mA cm –2 ) for ammonia on Fe–Ru/C 3 N–C 2 N is –0.22 V RHE . This leads to a calculated TOF of 434 h –1 per Fe–Ru site. In conclusion, we expect that the mechanisms for NRR and HER developed here will help lead to new generations of NRR with high TOF and FE.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A new quinoline-based cobalt( II ) catalyst capable of bifunctional water splitting

We report on a new water-soluble cobalt( II ) complex capable of water splitting bifunctionality, i.e., water reduction and water oxidation. The species [Co II (L Qpy )H 2 O]ClO 4 (1), where L Qpy is the deprotonated form of the new tripodal ligand N 1 ,N 1 -bis(pyridin-2-ylmethyl)-N 2 -(quinolin-8-yl)benzene-1,2-diamine, HL Qpy , was developed aiming to replace an oxidation prone methylene group by a sturdy and redox stable quinoline. The molecular and electronic structures of 1 were evaluated by multiple spectroscopic, spectrometric, electrochemical and computational methods, and detailed pre- and post-catalytic studies were conducted to ascertain the molecular nature of the conversions. Complex 1 performs water reduction at a low onset overpotential (η) of 0.65 V at pH 7, reaching TON 3h 2900 (TOF 970 h −1 ) and TON 18h 12 100 (TOF 672 h −1 ) with up to 98% faradaic efficiency (FE). Species 1 also promotes water oxidation at η = 0.34 V under pH 8, achieving TON 3h 193 (TOF 64 h −1 ) at 84% FE. Experimental and DFT results enabled us to propose reaction intermediates and mechanisms.

Lucecki, Carlos A. [Wayne State University, Detroi↗

Vacuum ultraviolet photodissociation and surface morphology change of water ice films dosed with hydrogen chloride

Time-of-flight (TOF) spectra of photofragment H atoms from the photodissociation of water ice films at 193 nm were measured for amorphous and polycrystalline water ice films with and without dosing of hydrogen chloride at 100-145 K. The TOF spectrum is sensitive to the surface morphology of the water ice film because the origin of the H atom is the photodissociation of dimerlike water molecules attached to the ice film surfaces. Adsorption of HCl on a polycrystalline ice film was found to induce formation of disorder regions on the ice film surface at 100-140 K, while the microstructure of the ice surface stayed of polycrystalline at 145 K with adsorption of HCl. The TOF spectra of photofragment Cl atoms from the 157 nm photodissociation of neutral HCl adsorbed on water ice films at 100-140 K were measured. These results suggest partial dissolution of HCl on the ice film surface at 100-140 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A homemade high-resolution orthogonal-injection time-of-flight mass spectrometer with a heated capillary inlet

We describe a homemade high-resolution orthogonal-injection time-of-flight (O-TOF) mass spectrometer combing a heated capillary inlet. The O-TOF uses a heated capillary tube combined with a radio-frequency only quadrupole (rf-only quadrupole) as an interface to help the ion transmission from the atmospheric pressure to the low-pressure regions. The principle, configuration of the O-TOF, and the performance of the instrument are introduced in this paper. With electrospray ion source, the performances of the mass resolution, the sensitivity, the mass range, and the mass accuracy are described. We also include our results obtained by coupling atmospheric pressure matrix-assisted laser deporption ionization with this instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resonant Ionization Laser Ion Source (RILIS) With Improved Selectivity Achieved By Ion Pulse Compression Using In-Source Time-of-flight Technique

This paper describes for the first time the improved selectivity of the RILIS made possible by the time-of-flight (TOF) ion bunch compression. Brief description of the compression principles and some preliminary experimental results are presented. In the off-line experiments short ion peaks of natural Li, Na, K, Tm and Yb are observed as ions leave the RILIS-TOF structure. For Tm the ion peaks of 5 {mu}s half-height duration are detected and 1 {mu}s peaks for Sn are predicted. In view of the repetition rate of the ISOLDE-RILIS lasers it is hoped that the selectivity of Sn isotopes production may be improved as much as 100 employing the RILIS with the TOF ion bunch compression and a gating technique.

74 ATOMIC AND MOLECULAR PHYSICS↗

Ion spectrometer composed of time-of-flight and Thomson parabola spectrometers for simultaneous characterization of laser-driven ions

An ion spectrometer, composed of a time-of-flight spectrometer (TOFS) and a Thomson parabola spectrometer (TPS), has been developed to measure energy spectra and to analyze species of laser-driven ions. Two spectrometers can be operated simultaneously, thereby facilitate to compare the independently measured data and to combine advantages of each spectrometer. Real-time and shot-to-shot characterizations have been possible with the TOFS, and species of ions can be analyzed with the TPS. The two spectrometers show very good agreement of maximum proton energy even for a single laser shot. The composite ion spectrometer can provide two complementary spectra measured by TOFS with a large solid angle and TPS with a small one for the same ion source, which are useful to estimate precise total ion number and to investigate fine structure of energy spectrum at high energy depending on the detection position and solid angle. Advantage and comparison to other online measurement system, such as the TPS equipped with microchannel plate, are discussed in terms of overlay of ion species, high-repetition rate operation, detection solid angle, and detector characteristics of imaging plate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of the highest acceleration gradient for ions produced with a long laser pulse

Ultrafast plasma light ion streams have been produced using the 300 ps, kJ-class iodine laser, operating at PALS Centre in Prague. Ion detection was performed through standard ion collectors (IC) in time-of-flight configuration (TOF), shielded by thin metallic absorbers. This new diagnostics technique has been theoretically studied and experimentally tested in order to cut the long photopeak contribution and to analyze the ultrafast particle signal. Processing the obtained experimental IC-TOF data, including deconvolution processes of the TOF signals, UV/soft-x-ray photopeak absorption, and ion transmission calculations for different metallic filters, is shown. Mainly amorphous carbon (graphite) targets have been irradiated in order to limit the maximum number of ion charge states and to focus our study on demonstrating the validity of the proposed investigation technique. Maximum ion energy and acceleration gradient estimations as a function of the laser energy and focal spot diameter are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large-Area Fast-Timing Systems In STAR

The STAR experiment at RHIC concentrates on the tracking of charged hadrons via ionization, and the detection of electrons and photons via calorimetry, in a wide and azimuthally complete acceptance. STAR's ability to directly identify charged hadrons was initially limited to low momenta. This has been addressed via the construction of a large-area Time-of-Flight (TOF) system based on small Multigap Resistive Plate Chambers (MRPCs). The installation of the STAR TOF system was completed last fall. The full system is ran well in the recent RHIC Run 10. The operation of the system, and its performance for particle identification, during RHIC Runs 9 and 10 will be described. STAR's ability to identify muons is also extremely limited. Another large-area TOF system based on much larger MRPCs is envisioned. This system will be located outside the STAR magnet and is called the Muon Telescope Detector (MTD). Several different prototype MTD systems were operated in Runs 7 through 10, and a patch of near-final MTD detectors is under construction for use in the upcoming Run 11. The performance of the MTD prototype detectors, and the design of the Run 11 installation and the full system, will be described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Porosity detection in ceramic armor tiles via ultrasonic time-of-flight

Some multilayer armor panels contain ceramic tiles as one constituent, and porosity in the tiles can affect armor performance. It is well known that porosity in ceramic materials leads to a decrease in ultrasonic velocity. We report on a feasibility study exploring the use of ultrasonic time-of-flight (TOF) to locate and characterize porous regions in armor tiles. The tiles in question typically have well-controlled thickness, thus simplifying the translation of TOF data into velocity data. By combining UT velocity measurements and X-ray absorption measurements on selected specimens, one can construct a calibration curve relating velocity to porosity. That relationship can then be used to translate typical ultrasonic C-scans of TOF-versus-position into C-scans of porosity-versus-position. This procedure is demonstrated for pulse/echo, focused-transducer inspections of silicon carbide (SiC) ceramic tiles.

07 ISOTOPE AND RADIATION SOURCES↗

Deuterated Liquid Scintillators: A New Tool for Neutron Measurements

The response of large (4x6) deuterated liquid scintillators (up to 10 cm diameter by 15 cm) to neutrons in the energy range from 0.5 MeV to 20 MeV has been studied using several nuclear reactions, including d(d,n), and {sup 12}C(d,n){sup 13}N, at the University of Notre Dame FN tandem accelerator. The latter two reactions utilized 9 MeV and 16 MeV deuteron beams, including a pulsed beam that also permitted time-of-flight (ToF) measurements. Combining pulse-shape discrimination and (ToF) allows gating on specific neutron energy groups to determine the detector response to specific neutron energies. Newly-obtained and optimized pulse shape discrimination using digitized pulse analysis from these detectors will be presented in this paper. These measurements confirmed the ability of these detectors to provide useful neutron spectra without ToF.

43 PARTICLE ACCELERATORS↗

Improving metastable impact electron spectroscopy and ultraviolet photoelectron spectroscopy signals by means of a modified time-of-flight separation

The separation of ultraviolet photoelectron spectroscopy (UPS) and metastable impact electron spectroscopy (MIES) is usually performed by a time-of-flight (ToF) separation using pre-set ToF for both types of signal. In this work, we present a new, improved ex situ signal separation method for the separation of MIES and UPS for every single measurement. Signal separation issues due to changes of system parameters can be overcome by changing the ToF separation and therefore allowing for the application of a wider range of measuring conditions. The method also enables to identify and achieve separation of the two signals without any time consuming calibration and the use of any special material for the calibration. Furthermore, changes made to the discharge source are described that enable to operate an existing MIES/UPS source over a broader range of conditions. This allows for tuning of the yield of UV photons and metastable rare gas atoms leading to an improved signal to noise ratio. First results of this improved setup are well in agreement with spectra reported in literature and show increased resolution and higher signal intensities for both MIE and UP spectra compared to the previous, non-optimized setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A design for a compact time-of-flight mass spectrometer

The design of a prototype, compact time-of-flight (TOF) mass spectrometer (MS) is described. The system primarily consists of an ion acceleration/focusing/steering assembly (AFSA), an 8 cm field-free region, a 4 cm, dual-stage reflectron and a miniature microchannel plate detector. Consequently, the resulting flight length of the system is 12 cm. The system has been designed with the capability to sample directly from atmosphere at ambient pressures. This is accomplished through the use of an electrodynamic ion funnel, housed in an intermediate-vacuum chamber that is coupled to the inlet of the TOF chamber. TOF spectra were obtained using noble gases (Ar, Kr and Xe) as test chemicals. These measured flight times were used to probe the performance of the instrument. A temporal resolution (tflight/Δt) of approximately 125, acquired using 129Xe+, has been measured for the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-of-flight secondary ion mass spectrometry with transmission of energetic primary cluster ions through foil targets

We developed time-of-flight (TOF) secondary ion (SI) mass spectrometry that provides informative SI ion mass spectra without needing a sophisticated ion beam pulsing system. In the newly developed spectrometry, energetic large cluster ions with energies of the order of sub MeV or greater are used as primary ions. Because their impacts on the target surface produce high yields of SIs, the resulting SI mass spectra are informative. In addition, the start signals necessary for timing information on primary ion incidence are provided by the detection signals of particles emitted from the rear surface of foil targets upon transmission of the primary ions. This configuration allows us to obtain positive and negative TOF SI mass spectra without pulsing system, which requires precise control of the primary ions to give the spectra with good mass resolution. We also successfully applied the TOF SI mass spectrometry with energetic cluster ion impacts to the chemical structure characterization of organic thin film targets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time of flight emission spectroscopy of laser produced nickel plasma: Short-pulse and ultrafast excitations

We report the experimental investigation and comparison of the temporal features of short-pulse (7 ns) and ultrafast (100 fs) laser produced plasmas generated from a solid nickel target, expanding into a nitrogen background. When the ambient pressure is varied in a large range of 10⁻⁶Torr to 10²Torr, the plume intensity is found to increase rapidly as the pressure crosses 1 Torr. Time of flight (TOF) spectroscopy of emission from neutral nickel (Ni I) at 361.9 nm (3d⁹(²D) 4p → 3d⁹(²D) 4s transition) reveals two peaks (fast and slow species) in short-pulse excitation and a single peak in ultrafast excitation. The fast and slow peaks represent recombined neutrals and un-ionized neutrals, respectively. TOF emission from singly ionized nickel (Ni II) studied using the 428.5 nm (3p⁶3d⁸(³P) 4s→ 3p⁶3d⁹ 4s) transition shows only a single peak for either excitation. Velocities of the neutral and ionic species are determined from TOF measurements carried out at different positions (i.e., at distances of 2 mm and 4 mm, respectively, from the target surface) on the plume axis. Measured velocities indicate acceleration of neutrals and ions, which is caused by the Coulomb pull of the electrons enveloping the plume front in the case of ultrafast excitation. Both Coulomb pull and laser-plasma interaction contribute to the acceleration in the case of short-pulse excitation. These investigations provide new information on the pressure dependent temporal behavior of nickel plasmas produced by short-pulse and ultrafast laser pulses, which have potential uses in applications such as pulsed laser deposition and laser-induced nanoparticle generation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Avalanche photodiode based time-of-flight mass spectrometry

This study reports on the performance of Avalanche Photodiodes (APDs) as a timing detector for ion Time-of-Flight (TOF) mass spectroscopy. We found that the fast signal carrier speed in a reach-through type APD enables an extremely short timescale response with a mass or energy independent <2 ns rise time for <200 keV ions (1−40 AMU) under proper bias voltage operations. When combined with a microchannel plate to detect start electron signals from an ultra-thin carbon foil, the APD comprises a novel TOF system that successfully operates with a <0.8 ns intrinsic timing resolution even using commercial off-the-shelf constant-fraction discriminators. By replacing conventional total-energy detectors in the TOF-Energy system, APDs offer significant power and mass savings or an anti-coincidence background rejection capability in future space instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wavelength-independent constant period spin-echo modulated small angle neutron scattering

Spin-Echo Modulated Small Angle Neutron Scattering (SEMSANS) in Time-of-Flight (ToF) mode has been shown to be a promising technique for measuring (very) small angle neutron scattering (SANS) signals and performing quantitative Dark-Field Imaging (DFI), i.e., SANS with 2D spatial resolution. However, the wavelength dependence of the modulation period in the ToF spin-echo mode has so far limited the useful modulation periods to those resolvable with the limited spatial resolution of the detectors available. Here we present our results of an approach to keep the period of the induced modulation constant for the wavelengths utilised in ToF. This is achieved by ramping the magnetic fields in the coils responsible for creating the spatially modulated beam in synchronisation with the neutron pulse, thus keeping the modulation period constant for all wavelengths. Such a setup enables the decoupling of the spatial detector resolution from the resolution of the modulation period by the use of slits or gratings in analogy to the approach in grating-based neutron DFI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lateral charge carrier transport properties of B-10 enriched hexagonal BN thick epilayers

Neutron detectors based on B-10 enriched hexagonal boron nitride (h- 10 BN or h-BN) epilayers have demonstrated the highest thermal neutron detection efficiency among solid-state neutron detectors at about 58%. However, many fundamental transport parameters of h-BN, including the room temperature carrier mobility, minority carrier lifetime, and surface recombination velocity, which are essential to the performance of detectors, are still unknown. Here, we report here the carrier drift mobilities ( μ ) and lifetimes (τ) of both electrons and holes in h- 10 BN epilayers measured by using a time-of-flight (TOF) technique. Lateral photoconductive type detectors fabricated from a 65 μm thick freestanding h- 10 BN epilayer were utilized to carry out the TOF measurements, which revealed μ e ~34 cm 2 /V s for electrons and μ h ~36 cm 2 /V s for holes and carrier lifetimes on the order of tens of microseconds. By combining the values of μ measured from TOF with S /μ (the ratio of the surface recombination velocity to mobility) deduced directly from the bias voltage dependence of photocurrent, S for both electrons ( S e ~1.4 × 10 4 cm/s) and holes ( S h ~2.7 × 10 3 cm/s) in h- 10 BN has been extracted. The determination of these important fundamental parameters (μ, τ, and S ) not only provides a better understanding of the carrier dynamics and electrical transport properties of h-BN but is also valuable for further advancing the development of h-BN materials and devices.

15 GEOTHERMAL ENERGY↗

Importance learning estimator for the site-averaged turnover frequency of a disordered solid catalyst

For disordered catalysts such as atomically dispersed “single-atom” metals on amorphous silica, the active sites inherit different properties from their quenched-disordered local environments. The observed kinetics are site-averages, typically dominated by a small fraction of highly active sites. Standard sampling methods require expensive ab initio calculations at an intractable number of sites to converge on the siteaveraged kinetics. We present a new method that efficiently estimates the site-averaged turnover frequency (TOF). The new estimator uses the same importance learning algorithm [Vandervelden et al., React. Chem. Eng. 5, 77 (2020)] that we previously used to compute the siteaveraged activation energy. We demonstrate the method by computing the site-averaged TOF for a simple disordered lattice model of an amorphous catalyst. The results show that with the importance learning algorithm, the site-averaged TOF and activation energy can now be obtained concurrently with orders of magnitude reduction in required ab initio calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗