Qualitative and quantitative analysis of neutron irradiation effects in SiC/SiC composites using X-ray computed tomography

Silicon carbide fiber-reinforced silicon carbide matrix (SiC/SiC) composites are candidate materials for cladding of light water reactor (LWR) fuels. Loss of fission product gas retention due to the formation of microcrack networks is considered a potential failure mechanism for SiC/SiC-cladded fuels. In this work, a variety of SiC/SiC composite tubes were irradiated with and without an LWR-relevant radial heat flux in the High Flux Isotope Reactor, followed by detailed characterization with X-ray computed tomography (XCT). This first set of XCT data for neutron-irradiated samples confirmed that the internal stresses arising from a combination of temperature gradients and irradiation-induced swelling act as the primary driver for cracking. Consequently, while the observed cracking patterns varied depending on the tube architectures, the sharp edges of relatively large pores were found to be the common stress concentrator. These findings are useful to help improve the design and manufacturing of SiC/SiC fuel claddings for reduced failure probability.

42 ENGINEERING↗

Refined views of ancient ocean chemistry: Tracking trace element incorporation in pyrite framboids using atom probe tomography

The trace element chemistry of pyrite can be used to determine the origin, timing, and conditions of formation of ore deposits; as a vectoring tool for mineral exploration; and to determine the evolution of the Earth’s oceanic and atmospheric chemistry. However, little is known about whether trace elements are held with the pyrite structure or within nano-inclusions of other phases. This distinction is important for two primary reasons. First, trace element incorporation into the pyrite structure can affect the partitioning of other trace elements. Second, if trace elements are held within nano-inclusions, the partition coefficient of the mineral phases that make up the nano-inclusion, rather than pyrite, are the critical consideration in related interpretations. Previous studies addressing this topic have used laser ablation inductively coupled plasma mass spectrometry; however, the resulting data do not provide sufficient spatial resolution to delineate trace element distributions unless the inclusions are large. Further, they use these flat element profiles in time resolved laser ablation output graphs to argue that pyrite trace element content provides a direct relationship between trace element content of seawater and pyrite trace element content. To improve resolution, we have used atom probe tomography to characterize trace element distributions in pyrite framboids from the Cariaco Basin and Demerara Rise in three-dimensions at sub-nanometer resolution. Manganese was found to be concentrated in the pyrite nanocrystal part of the original framboid structure. In contrast, Ni was mostly found along the grain boundary, though it still appeared to be contained within the pyrite structure. Copper was concentrated in later pyrite overgrowths, and As varied in its location. These observations suggest that some important trace elements are incorporated into pyrite during early diagenesis, even in euxinic settings dominated by water-column pyrite formation. Statistical analysis was used to determine whether trace elements were incorporated in the lattice or within nanoscale inclusions (referred to here are nano-inclusions). We found that As, Ni, Cu, and Mn were commonly held within the pyrite structure, but As, Ni, and Cu can also be held as nano-inclusions or within grain interfaces. Incorporation of As is known to enhance the incorporation of other trace elements and in this case appears to correlated to elevated Ni and Cu concentrations in the Cariaco Basin samples. Furthermore, understanding these relationships strongly impacts our ability to utilize pyrite trace metal concentrations to analyze and quantify early ocean chemistry and its evolution through time.

54 ENVIRONMENTAL SCIENCES↗

Comparison of automated chemical-guided segmentation and human annotation of soil organic matter in X-ray microcomputed tomography imaging in contrasted soil types

Soil organic matter (OM) formation and persistence is strongly influenced by the spatial distribution of organic substrates and microscale soil heterogeneity by dictating OM accessibility to microorganisms. However, traditional size and/or density fractionation techniques disrupt aggregate architecture, eliminating spatial information needed to fully understand intra-aggregate OM distribution. To quantify three-dimensional OM spatial distribution and automate segmentation in X-ray microcomputed tomography (µCT) imaging without human annotation bias, we developed an iodine gas vapor (I2) based staining workflow that eliminates labor-intensive manual annotation while maintaining segmentation accuracy, using aggregates from four taxonomically diverse soils (Xerofluvent, Haploxeroll Sphagnofibrist, Palehumult) with an 8-fold range of soil organic carbon. Human annotation of 10 µCT slices by the experienced and inexperienced annotators resulted in variations up to 3% in the Dice similarity coefficient (DSC), reflecting a degree of inherent subjectivity of manual labeling. Such inconsistencies are expected to compound as the number of manually annotated slices increases. Dual-energy µCT imaging at 33.1 keV (below the iodine (I) K-edge) and 33.2 keV (above the I K-edge) was used to resolve aggregate microstructure following I2 staining. The automated image subtraction pipeline identified OM regions by the I Kedge induced brightness increases, achieving DSC values of 0.58–0.83 relative to an experienced annotator. Sensitivity analyses revealed that the reconstruction alpha value—optimized via the open-source tool TomocuPy—and the 3D registration slice count were the primary determinants of accuracy, providing a novel benchmark for dual-energy soil imaging. The pipeline without GPU acceleration achieved 9.6 to 43.2 times faster than manual annotation. Using GPU-accelerated image post-processing and affine transformation matrices, the pipeline successfully segmented OM elements for large-scale datasets (3232×3232 pixel, 2048 slices) within ~5200 s from raw file acquisition to segmented output. The high-throughput approach enables the quantification of OM spatial distribution across diverse and heterogeneous soil.

Soil microbial biomass↗

Automated 3D cytoplasm segmentation in soft X-ray tomography

Cells’ structure is key to understanding cellular function, diagnostics, and therapy development. Soft X-ray tomography (SXT) is a unique tool to image cellular structure without fixation or labeling at high spatial resolution and throughput. Fast acquisition times increase demand for accelerated image analysis, like segmentation. Currently, segmenting cellular structures is done manually and is a major bottleneck in the SXT data analysis. This paper introduces ACSeg, an automated 3D cytoplasm segmentation model. ACSeg is generated using semi-automated labels and 3D U-Net and is trained on 43 SXT tomograms of immune T cells, rapidly converging to high-accuracy segmentation, therefore reducing time and labor. Furthermore, adding only 6 SXT tomograms of other cell types diversifies the model, showing potential for optimal experimental design. ACSeg successfully segmented unseen tomograms and is published on Biomedisa, enabling high-throughput analysis of cell volume and structure of cytoplasm in diverse cell types.

59 BASIC BIOLOGICAL SCIENCES↗

Unraveling the advances of trace doping engineering for potassium ion battery anodes via tomography

Doping have been considered as a prominent strategy to stabilize crystal structure of battery materials during the insertion and removal of alkali ions. The instructive knowledge and experience acquired from doping strategies predominate in cathode materials, but doping principle in anodes remains unclear. Here, we demonstrate that trace element doping enables stable conversion-reaction and ensures structural integrity for potassium ion battery (PIB) anodes. With a synergistic combination of X-ray tomography, structural probes, and charge reconfiguration, we encode the physical origins and structural evolution of electro-chemo-mechanical degradation in PIB anodes. By the multiple ion transport pathways created by the orderly hierarchical pores from “surface to bulk” and the homogeneous charge distribution governed in doped nanodomains, the anisotropic expansion can be significantly relieved with trace isoelectronic element doping into the host lattice, maintaining particle mechanical integrity. Our work presents a close relationship between doping chemistry and mechanical reliability, projecting a new pathway to reengineering electrode materials for next-generation energy storage.

25 ENERGY STORAGE↗

Method for measurement of TRISO kernel and layer volumes by X-ray computed tomography

Layer dimensions are key parameters for as-fabricated tristructural-isotropic (TRISO) particle fuel as well as for post-irradiation examination of particle performance. Layer thicknesses are typically measured by optical microscopy of the particle cross section near mid-plane, while layer volumes are estimated with serial sectioning and microscopy. This method for measuring layer volumes is limited due to the resolution limit imposed by slice thickness and the effect of the polishing process on delicate irradiated particle microstructures. In this study, image processing software has been developed to segregate the three-dimensional (3D) TRISO particle images provided by x-ray computed tomography (XCT) into high-resolution volumetric data for the kernel, all particle layers, and any internal voids introduced during irradiation. These data can be used to analyze key in-reactor behaviors of TRISO particles such as kernel swelling or buffer shrinkage, which are important inputs for fuel performance modeling.

36 MATERIALS SCIENCE↗

Atom Probe Tomography Characterization of High-Dose Ion Irradiated MA957

This paper presents a comprehensive characterization study of the microstructural responses to ion irradiation of the oxide dispersion strengthened (ODS) ferritic alloy MA957 using atom probe tomography (APT). The MA957 specimens were irradiated by 1.8 MeV Cr3+ ions to doses and temperatures relevant to advanced fast reactors (100 and 500 dpa at 400-500 °C). The average sizes of the YTiO particles decreased slightly after irradiation at all temperatures, with the most pronounced change at 400 °C. The particle number densities for 400 and 500 °C were slightly below number densities for the unirradiated condition, while the values were slightly higher at 420 and 450 °C. This behavior is consistent with the Nelson-Hudson-Mazey rate theory model that considers the competing effects between recombination and dissolution. An increase in the Y/Ti ratio of the YTiO particles was observed at the two lower temperatures. The formation of Cr-rich precipitates (a') was observed in specimens irradiated at temperatures up to 450 °C. Irradiation-induced segregation on grain boundaries was also investigated. Grain boundary element concentration profiles and ion maps demonstrate differences among the irradiation temperatures, with most datasets differing from the unirradiated condition. A key focus of this ion irradiation study is the high-dose response, and this quantitative assessment revealed relatively small but distinct effects of irradiation on microstructure evolution. Overall, these results showing minor second phase evolution suggest that MA957 should retain mechanical performance generally well up to 500 dpa for the irradiation temperatures studied.

Wang, Jing↗

Atom probe tomography characterization of ion and neutron irradiated Alloy 800H

Alloy 800H is a high temperature and creep resistant alloy, and is considered as a candidate alloy for use in Generation IV nuclear reactor systems. To clarify the alloy's behavior under irradiation, samples were subjected to single ion irradiations up to 20 dpa at 440°C, a dual ion/He irradiation to 17 dpa at 460°C, and a neutron irradiation to 17 dpa at 385°C. The irradiated microstructures were characterized using atom probe tomography to complement previously published transmission electron microscopy studies. Additionally, after single ion irradiation, sparse fine Al and Ti clusters were observed after 1dpa, while high number densities of nanoscale Ni-Al-Ti clusters, Cr-Ti rich carbides, and Si-decorated dislocation loops developed after 10 and 20 dpa. The microstructure formed during single ion irradiation exhibited a strong depth dependence. No significant differences were observed between the single and dual ion irradiations. While Ni-Al-Ti clusters, Cr-Ti rich carbides, and Si-decorated dislocation loops were also observed after neutron irradiation, the neutron-irradiated microstructure differed from those found in the ion-irradiated samples.

36 MATERIALS SCIENCE↗

Microstructure of irradiated AGR TRISO particle buffer layers as measured by X-ray computed tomography

Shrinkage of the initially low-density buffer layer in tristructural isotropic (TRISO) coated fuel particles during irradiation is a well-known phenomenon with potential implications for fission product and actinide transport, as well as potential pyrocarbon fracture that in some cases has been observed to impact particle performance. During post-irradiation examination, the buffer layer's structure is commonly determined using 2D microscopy of a particle cross section or a series of particle cross sections at staggered depths. Although these methods provide a general idea of the irradiated buffer microstructure, they do not provide a full picture of the TRISO coating microstructure. By contrast, x-ray computed tomography (XCT) provides full 3D imaging of the TRISO particle. Particles from various compacts irradiated for the Advanced Gas Reactor Fuel Development and Qualification Program were imaged using XCT. Some of these particles were selected because of abnormal fission product inventories (e.g., low 137 Cs), whereas others were randomly selected from the center of the fission product inventory distribution. Qualitative and quantitative analysis techniques were applied to the randomly selected particles as representatives of typical TRISO behavior to study the post-irradiation structure of the buffer layer. These results showed that, while separation of the buffer and inner pyrolytic carbon layers was a common behavior during the radiation-induced shrinkage of the buffer, a portion of the original buffer/inner pyrolytic carbon interface remained intact throughout irradiation in nearly all cases. Furthermore, these results also indicated clear trends in the degree of buffer densification with irradiation temperature and fluence.

36 MATERIALS SCIENCE↗

AGR-2 irradiated TRISO particle IPyC/SiC interface analysis using FIB-SEM tomography

In this work, the morphology in the interface region between the inner pyrolytic carbon layer (IPyC) and silicon carbide (SiC) layers in tristructural-isotropic (TRISO) particle fuel from the AGR-2 irradiation experiment were studied using focused ion beam-scanning electron microscopy tomography. This work quantitatively described the interface and corresponding relevant metrics to understand how the microstructural features at the IPyC/SiC interface may influence actinide and fission product interactions with the SiC layer. Particles were selected with varied 110m Ag retention rates, and their volumes were reconstructed and analyzed for distributions of pores, fission product/actinide features, SiC, and IPyC. It was found that porosity accommodates fission products in the interface and SiC layers. The largest fission product/actinide precipitates were found in the interface region. This was also where the largest number fraction of fission products/actinides was found, consistent with SEM showing fission product/actinide pileup along selected areas of the interface region.

36 MATERIALS SCIENCE↗

Neutron Irradiation Induced Changes in Isotopic Abundance of 6Li and 3D Nanoscale Distribution of Tritium in LiAlO2 Pellets Analyzed by Atom Probe Tomography

Tritium, a radioactive isotope of hydrogen is produced by neutron irradiation of 6Li enriched LiAlO2 pellets in Tritium producing burnable absorber rods (TPBARs). Three-dimensional nanoscale mapping of Tritium in irradiated pellets is critical to understand its spatial variation and its association with various microstructural features in the pellets. Spatially resolved analysis of 6Li isotopic enrichment in such ceramic pellets before and after irradiation can provide insights to heterogeneities in Li isotopic distribution. However, Li being a light isotope, its spatially resolved compositional or isotopic analysis is a challenging task to most analytical methods. Here we used atom probe tomography, to evaluate the Li isotopic enrichment in both the LiAlO¬2 matrix and the Li deficient secondary phase LiAl5O8 before irradiation. These results were then compared with 6Li isotopic ratio measured by APT analysis of neutron irradiated pellets to clearly demonstrate the unique capability of APT to quantitatively analyze the isotopic enrichment of 6Li as well as for other light elements present in these materials. Evidence for heterogenous nanoscale distribution of 3H and O3H within irradiated pellet microstructure is also provided, which is attributed to 3H trapping in irradiation induced vacancy clusters or voids within the LiAlO2 matrix. The characterization results given here, now prove the feasibility for using APT for analyzing nanoscale spatially resolved isotopic enrichment of Li as well as other light elements such as Tritium in TPBARs. This work also paves way to adopt APT for analyzing light elements such as Li and tritium in materials used for nuclear fusion reactor applications, geochemistry, astrophysics as well as for energy storage applications.

Devaraj, Arun↗

Mapping 3D grain and precipitate structure during in situ mechanical testing of open-cell metal foam using micro-computed tomography and high-energy X-ray diffraction microscopy

Open-cell metal foams are ultra-low-density cellular metals with complex hierarchical structures that span bulk, cell, ligament, and sub-ligament scales and give rise to desirable properties such as high strength-to-weight ratio and excellent energy absorption. Although literature suggests that intrinsic material structures at sub-ligament length scales (e.g., grains and precipitates) play an important role in mechanical behavior of open-cell metal foams, there are very few experimental measurements of such structures in three dimensions and for meaningful volumes of foam. This study seeks to map and track the three-dimensional (3D) grain and precipitate structures of an intact volume of open-cell aluminum foam by advancing microstructural characterization techniques that leverage X-ray micro-computed tomography (μCT) and far-field high-energy X-ray diffraction microscopy (FF-HEDM). A 6%-relative-density aluminum foam sample was mechanically tested in compression while μCT and FF-HEDM measurements were collected at interrupted loading states at beamline 1-ID of the Advanced Photon Source. Further, a new scanning strategy and reconstruction algorithm were established to enable characterization of a foam volume with diameter approximately four times wider than the nominal width of the X-ray beam. The result is a set of maps that detail both the 3D grain and precipitate structures throughout the foam volume at successive strain steps. A novel grain tracking procedure was developed to track individual grains within the foam volume by accounting for the large rigid-body motions that individual ligaments can undergo during mechanical loading. The ability to track grains and precipitate structures in three dimensions throughout large bulk deformation of ultra-low-density polycrystalline materials enables new possibilities for validating numerical models and investigating local failure mechanisms. Furthermore, the methods and procedures developed in this study could be applied to other ultra-low-density structures, such as additively manufactured lattices.

36 MATERIALS SCIENCE↗

Dual X-ray computed tomography-aided classification of melt pool boundaries and flaws in crept additively manufactured parts

In metal additive manufacturing (AM), understanding the process-structure-performance relationships requires a combination of multi-scale characterization techniques that allows for the measurement of the melt pool shape and boundary and classifying various defects and flaws in the AM parts. Such approaches can be destructive, only 2D in nature, or have a small field of view and can be complex to co-register and analyze. Here, in this work, we present a non-destructive 3D inspection technique that employs dual-energy X-ray computed tomography (XCT) along with a model-based iterative reconstruction (MBIR) and a new segmentation algorithm. The proposed approach and algorithm are not only capable of classifying and quantifying flaws such as pores, cracks, and inclusions, but they also allow for the extraction of microstructural features such as melt pool boundaries (MPB) and melt pool regions (MPR), that can help understand process-structure-performance relationships for alloys under study. As an exemplar application, we employed the method for characterization of an additively manufactured aluminum alloy crept under tensile stress at 300 °C for 1064 h. Our results demonstrate high quality segmentation and classification of various flaws and MPB and MPR, for the first time, using 3D X-ray CT inspection. The delineated MPB and MPR in the crept samples reveal the preferential growth paths of cracks that formed during creep deformation. The technique was used for successfully quantifying the characteristics (number of defects, their density, volume fraction, etc.) of the manufacturing-induced pores and creep-induced cracks, which is necessary to better understand the creep failure mechanisms of the material.

36 MATERIALS SCIENCE↗

Sigma phase evolution and nucleation mechanisms revealed by atom probe tomography in a 347H stainless steel

The size evolution and phase composition of sigma phases were investigated for a 347H stainless steel subject to isothermal aging at 750 °C for up to 10,000 h. Scanning electron microscopy reveals that sigma phases are present before 336 h aging and they continue to grow for all aging times studied. Atom probe tomography shows little variation in the sigma phase composition with aging time up to 10,000 h, and only the C content decreases with aging time. The comparison of C concentration suggests that the sigma phase does not nucleate within the C-depleted matrix or precipitate free grain boundaries, leaving dissolving metastable M 23 C 6 as the only possible nucleation site. Based on the experimental results and thermodynamic simulations, the desirable Nb concentration is discussed to reduce the kinetics of sigma phase growth, and possible design directions are suggested to improve 347H.

36 MATERIALS SCIENCE↗

Strategy to safely enable X-ray computed tomography examination of highly radioactive tristructural isotropic nuclear fuel

Nondestructive post-irradiation examination of nuclear fuels and materials is useful in collecting data to inform commercial licensing of new nuclear concepts. This work details the planning, shielding design, and workflow of an X-ray computed tomography examination of an irradiated AGR-5/6/7 fuel compact with a dose rate of 1318 R/hr on contact from both β and ɤ-ray radiation with 120 R/hr of the dose rate coming exclusively from ɤ-rays. Post-irradiation examination of highly radioactive samples can help reduce the timeframe from conceptualization of novel nuclear concepts to their commercial implementation as not only is less time spent waiting for experiments to decay away to acceptable levels for examinations, but data from these experiments can more quickly inform model efforts and subsequent experiments. While this work represents the hottest radiological sample that has been openly transported and examined at Idaho National Laboratory’s Irradiated Materials Characterization Laboratory to date, it is anticipated that this work and its lessons learned will facilitate future examinations of similar or even more radioactive specimens.

42 - ENGINEERING↗

Evaluation of a positron-emission-tomography-based SiPM readout for compact segmented neutron imagers

Gamma-ray emission from special nuclear material (SNM) is relatively easy to shield from detection using modest amounts of high-Z material. In contrast, fast-neutrons are much more penetrating and can escape relatively thick high-Z shielding without losing significant energy. Furthermore, fast neutrons provide a clear and unambiguous signature of the presence of SNM with few competing natural background sources. The challenge of detecting fast neutrons is twofold. First, the neutron flux from SNM are only a fraction of the corresponding gamma-ray flux. Second, fast neutrons can be difficult to differentiate from gamma rays. The ability to discriminate gamma rays from neutrons, combined with a neutron imaging capability, can in some situations enable the localization of SNM neutron sources distinct from background. With the developments of pulse-shape-sensitive plastic scintillators that offer excellent gamma-ray/neutron discrimination, and arrays of silicon photomultipliers combined with highly scalable and fast positron-emission-tomography (PET) multi-channel readout systems, field-deployable neutron imagers suitable for SNM detection might now be within reach. In this paper, we present a characterization of the performance of a recently available commercial PET-scanner readout, including its sensitivity to pulse-shape differences between fast neutrons and gamma rays, energy and timing resolution. Here, we find that, while the pulse-shape discrimination is achievable with stilbene, further improvement of the readout is required to achieve it with the PSD-capable available plastic scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Machine learning-assisted upscaling analysis of reservoir rock core properties based on micro-computed tomography imagery

Optimum solutions for geologic modeling and reservoir simulation in industries such as oil and gas recovery and carbon capture and storage require accurate characterization of reservoir properties, which are often heterogeneous. In this study, high-quality micro-computed tomography (CT) images (1.475-μm/pixel resolution) of a sandstone core acquired from the Bell Creek oil field, USA, were used to provide nondestructive analysis of pore- and core-scale heterogeneity across measurement scales of 94–566 μm. In addition to characterizing the as-received sample, the core sample was flooded with brine to evaluate the capacity of the core sample to receive injected fluids. The micro-CT images were systematically segmented into pore spaces and grains via machine learning (ML) steps including image preprocessing, label creation using a traditional ML method based on limited manual image annotation, and finally U-Net segmentation. The segmented image stacks were reconstructed into digital cubes of various scales of voxel lengths. The 3D porosity values were calculated for all the digital cubes, and the fractal dimensions of the cubes were estimated using a box-counting method. The results showed that smaller cubes had greater heterogeneity and that the porosity values could be accurately estimated by fractal dimension and voxel lengths using ML models. For the core sample with brine flooding, the ratio of pores filled by brine to the total pore space was related to the porosity and could also be accurately estimated by porosity, fractal dimension, and voxel lengths using ML models. In conclusion, the results of this study demonstrate that the concept of fractal dimension can be a useful vector to perform upscaling analysis of sandstone rock heterogeneity from the pore to core scale and that fractal dimensions can be used to estimate porosity values and pore space-filling capacity across those scales.

58 GEOSCIENCES↗

The Development of a Generalized Riser Flow Regime Map Based Upon Higher Moment and Chaotic Statistics Using Electrical Capacitance Volume Tomography (ECVT)

Dynamic analyses have been applied to the temporal signals from an Electro Capacitance Volume Tomography instrument located near mid-height on the riser of an industrial-scale cold-flow circulating fluidized bed to characterize gas-solids flow behavior in the riser. Twelve capacitance electrodes surround the cylindrical riser over a height of 1.3 m. The instrument used a neural network deconvolution algorithm to determine the spatially resolved solids fraction recorded at 52 Hz. Experiments were carried out over a range of gas and solids flows in the transport regime using a Geldart Group B bed material, high density polyethylene with mean particle size of 880 μm. The radial solids distribution was found to vary from one-time step to the next between profiles typical of laminar and turbulent flow. The duration of time spent in each of these flow profiles depended upon the operating regime – dilute, core-annular, or fast fluidized bed. The chaotic structure of the temporal data was characterized using the three conventional approaches: the first 4 moments from the distribution of signal in time, system memory parameters from the autocorrelation function and the Hurst exponent, and analysis of the correlationentropy and correlation dimension of the attractor. These signal analysis techniques were used to clearly distinguish differences between different transport operating regimes. Specifically, it was experimentally observed that a riser transitions from core annular flow profile to dilute and dense regimes via increasing the frequency of short term transients to either dilute or dense flow profiles, respectively. A regime map was generated based upon these dynamics using solids flux and gas velocity axes. Fast fluidized, core annular, and dilute each exhibited different degree of dynamic characteristics typical of fluid dominated or particle compromising behavior. It should be noted that the magnitude for the different statistics was in the same range regardless of the regime, it was the radial profile for the statistic that changed and subsequently identified that there was a change in the regime. Finally, a reduced regime map was developed consisting of plotting the gas velocity normalized by the upper transport velocity versus the solids flux normalized by the saturation carrying capacity. The use of this reduced plot allowed the data from widely different conditions to be plotted and compared on the same<p>graph. Note that in many instances, some of the statistics identified the operating point as being in one regime while others indicated that it was in another indicating a transition region between dilute or core annular regimes and between the core annular and fast fluidization regimes. This now provides a tool that can be used to optimize process performance, identify changes in operating states, or replicate process dynamics during process scaling or changing operating parameters. </p>

Breault, Ronald↗