Search NASA⌕ Search

SEARCH · Search NASA

Results for “TPC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Solar neutrino detection in a large volume double-phase liquid argon experiment

Precision measurements of solar neutrinos emitted by specific nuclear reaction chains in the Sun are of great interest for developing an improved understanding of star formation and evolution. Given the expected neutrino fluxes and known detection reactions, such measurements require detectors capable of collecting neutrino-electron scattering data in exposures on the order of 1 ktonne-yr, with good energy resolution and extremely low background. Two-phase liquid argon time projection chambers (LAr TPCs) are under development for direct Dark Matter WIMP searches, which possess very large sensitive mass, high scintillation light yield, good energy resolution, and good spatial resolution in all three cartesian directions. While enabling Dark Matter searches with sensitivity extending to the ''neutrino floor'' (given by the rate of nuclear recoil events from solar neutrino coherent scattering), such detectors could also enable precision measurements of solar neutrino fluxes using the neutrino-electron elastic scattering events. Modeling results are presented for the cosmogenic and radiogenic backgrounds affecting solar neutrino detection in a 300 tonne (100 tonne fiducial) LAr TPC operating at LNGS depth (3,800 meters of water equivalent). The results show that such a detector could measure the CNO neutrino rate with ∼15% precision, and significantly improve the precision of the {sup 7}Be and pep neutrino rates compared to the currently available results from the Borexino organic liquid scintillator detector.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark matter directional detection: comparison of the track direction determination

Several directional techniques have been proposed for a directional detection of Dark matter, among others anisotropic crystal detectors, nuclear emulsion plates, and low-pressure gaseous TPCs. The key point is to get access to the initial direction of the nucleus recoiling due to the elastic scattering by a WIMP. In this article, we aim at estimating, for each method, how the information of the recoil track initial direction is preserved in different detector materials. We use the SRIM simulation code to emulate the motion of the first recoiling nucleus in each material. We propose the use of a new observable, D , to quantify the preservation of the initial direction of the recoiling nucleus in the detector. We show that in an emulsion mix and an anisotropic crystal, the initial direction is lost very early, while in a typical TPC gas mix, the direction is well preserved.

79 ASTRONOMY AND ASTROPHYSICS↗

Commissioning of the ArDM experiment at the Canfranc underground laboratory: first steps towards a tonne-scale liquid argon time projection chamber for Dark Matter searches

The Argon Dark Matter (ArDM) experiment consists of a liquid argon (LAr) time projection chamber (TPC) sensitive to nuclear recoils, resulting from scattering of hypothetical Weakly Interacting Massive Particles (WIMPs) on argon targets. With an active target mass of 850 kg ArDM represents an important milestone towards developments for large LAr Dark Matter detectors. Here we present the experimental apparatus currently installed underground at the Laboratorio Subterráneo de Canfranc (LSC), Spain. We show data on gaseous or liquid argon targets recorded in 2015 during the commissioning of ArDM in single phase at zero E-field (ArDM Run I). The data confirms the overall good and stable performance of the ArDM tonne-scale LAr detector.

79 ASTRONOMY AND ASTROPHYSICS↗

The MicroBooNE continuous readout stream for detection of supernova neutrinos

Since the original detection of core-collapse supernova neutrinos in 1987, all large neutrino experiments seek to detect the neutrinos from the next nearby supernova. Among them, liquid argon time projection chambers (LArTPCs) offer a unique sensitivity to the electron neutrino flux of a supernova. However, the low energy of these events (scale of MeVs), and the fact that all large (multi-tonne) LArTPCs operating at the moment are located near the Earth's surface, and are therefore subject to an intense cosmic ray flux, makes triggering on the supernova neutrinos very challenging. Instead, MicroBooNE has pioneered a novel approach for detecting supernova neutrinos based on a continuous readout stream and a delayed trigger generated by other neutrino detectors (the Supernova Early Warning System, or SNEWS). MicroBooNE's data is stored temporarily for a few days, awaiting a SNEWS alert to prompt the permanent recording of the data. In order to cope with the large data rates produced by the continuous readout of the TPC and the PMT systems of MicroBooNE, FPGA-based zero-suppression algorithms have been developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Xenon doping of Liquid Argon in ProtoDUNE Single Phase: first results

Doping Liquid Argon (LAr) with xenon is a known technique to shift the light emitted by argon (128 nm) to a longer wavelength to ease its detection. The largest Xenon doping test ever performed in a LArTPC was carried out in ProtoDUNE Single Phase (ProtoDUNE-SP) at the CERN Neutrino Platform. The response of such a large TPC (7701 of Liquid Argon and 4401 of fiducial mass) has been studied using the ProtoDUNE Photon Detection System (PDS) and a dedicated setup installed before the run. With the first, it was possible to study the light detected in the system as a function of the xenon concentration and to characterise the light collection efficiency with respect to the track position. With the second system it was possible to disentangle the LAr (128 nm) light from the xenon (178 nm) light using two dedicated X-ARAPUCA modules. The run was fully satisfactory, it was possible to measure directly the increase of the xenon light component during doping; furthermore most of the LAr light quenched by impurities was fully recovered even at small Xenon concentration (< 20 ppm in mass). A study of the collected scintillation light as a function of the track position showed an improvement of the detector response uniformity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Purity monitoring for ProtoDUNE-SP

The Deep Underground Neutrino Experiment is a next-generation long-baseline neutrino oscillation experiment based on liquid argon time projection chamber technology. DUNE-s single-phase prototype ProtoDUNE-SP at CERN finished its two-year Phase-1 running in July 2021, successfully collected test-beam and cosmic ray data. A key aspect of LArTPC calibration is the lifetime of drift electrons. A purity monitor is a miniature TPC measuring the lifetime of electrons generated from the photocathode via the photoelectric effect. It enables continuous monitoring of the detector status, especially when filling the cryostat and when liquid argon recirculation systems operate. The purity monitoring system in ProtoDUNE-SP Phase-1 monitored liquid argon purity throughout its entire lifetime. It is essential to the experiment’s successful commissioning, operation, and data taking. This poster discusses the design, implementation, and results of purity monitors and plans.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time Projection Chambers instrumented with resistive MicroMegas for the SAND near detector of DUNE

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino accelerator experiment aiming for precise measurements of the neutrino oscillation parameters. DUNE will include a near detector complex regrouping three different detectors among which SAND (System for on-Axis Neutrino Detection) that will be the only one permanently on the neutrino beam axis in charge of monitoring in detail the emitted neutrino beam and its stability through time, a crucial characteristic to realize accurate oscillation measurements at the percent level. SAND will reuse the superconducting magnet and the electromagnetic calorimeter of the KLOE experiment. We will describe in the following the proposal of using, as inner tracker of SAND, a large 3D matrix of 1.5cm side scintillator cubes (3DST) surrounded by 3 gaseous Time Projection Chambers. This setup allows to realize accurate beam monitoring combining the 3DST unprecedented capability of neutron detection and energy measurement with the high precision momentum resolution for charged particles offered by the TPCs. The proposed TPC design allows to reach spatial resolutions of a few hundreds of micrometers using 1 cm pads by deploying the resistive MicroMegas technology for the charge readout.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Slicing with deep learning models at ProtoDUNE-SP

DUNE is a cutting-edge experiment aiming to study neutrinos in detail, with a special focus on the flavor oscillation mechanism. The prototype of the DUNE Far Detector Single Phase TPC (ProtoDUNE-SP) was built and operated at CERN with a full set of reconstruction tools. To implement these reconstruction tools, Pandora, a multi-algorithm framework, has been developed. A large number of these algorithms, some of them being exploiting traditional clustering, detector physics and deep learning approaches, have been applied to images to gradually build up a picture out of singular events. One of such algorithms is the Pandora slicing algorithm which aims to partition the detector hits of an event in sets called slices. Each slice represents a single interaction in the detector and should identify all the hits related to the interacting particle and its subsequent decay products. We expect the order of tens of slices per event in ProtoDUNE-SP. In this paper we present a deep learning approach to the problem, designing a model able to outperform the state-of-the-art slicing algorithm which is currently implemented within Pandora. We assess the performance of our tool in terms of efficiency and accuracy, while exploiting hardware accelerating setups. The ultimate goal is to incorporate this deep learning approach in the Pandora reconstruction tool.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Status of the MicroBooNE Experiment

The MicroBooNE experiment is an upcoming liquid argon TPC experiment which will pursue a program of short baseline neutrino physics in the Fermilab Booster Neutrino Beam, starting in early 2014. I give a description of the experiment and review the current status of various aspects of the MicroBooNE detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Summary of the Second Workshop on Liquid Argon Time Projection Chamber Research and Development in the United States

The second workshop to discuss the development of liquid argon time projection chambers (LArTPCs) in the United States was held at Fermilab on July 8-9, 2014. The workshop was organized under the auspices of the Coordinating Panel for Advanced Detectors, a body that was initiated by the American Physical Society Division of Particles and Fields. All presentations at the workshop were made in six topical plenary sessions: i) Argon Purity and Cryogenics, ii) TPC and High Voltage, iii) Electronics, Data Acquisition and Triggering, iv) Scintillation Light Detection, v) Calibration and Test Beams, and vi) Software. This document summarizes the current efforts in each of these areas. It primarily focuses on the work in the US, but also highlights work done elsewhere in the world.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Light-Based Triggering and Reconstruction of Michel Electrons in LArIAT

The LArIAT Experiment aims to calibrate the liquid argon time projection chamber (LArTPC) using a beam of charged particles at the Fermilab Test Beam Facility. It is equipped with a novel scintillation light readout system using PMTs and custom SiPM preamplifier boards to detect light from reflector foils coated with wavelength-shifting TPB. A trigger on delayed secondary flashes of light captures events containing stopping cosmic muons together with the Michel electrons coming from their subsequent decay. This dedicated Michel trigger supplies an abundant sample of low-energy electrons throughout the detector's active volume, providing opportunities to study the combined calorimetric capabilities of the light system and the TPC. Preliminary results using scintillation light to study properties of the Michel electron sample are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of scintillation and ionization yield with high-pressure gaseous mixtures of Xe and TMA for improved neutrinoless double beta decay and dark matter searches

The gaseous Xenon(Xe) time projection chamber (TPC) is an attractive detector technique for neutrinoless double beta decay and WIMP dark matter searches. While it is less dense compared to Liquid Xe detectors, it has intrinsic advantages in tracking capability and better energy resolution. The performance of gaseous Xe can be further improved by molecular additives such as trimethylamine(TMA), which is expected to (1) cool down the ionization electrons, (2) convert Xe excitation energy to TMA ionizations through Penning transfer, and (3) produce scintillation and electroluminescence light in a more easily detectable wavelength (300 nm). In order to test the feasibility of the performance improvements with TMA, in this paper we made the first direct measurement of Penning and fluorescence transfer efficiency with gaseous mixtures of Xe and TMA. While we observed a Penning transfer efficiency up to ~35%, we found strong suppression of primary scintillation light with TMA. We also found that the primary scintillation light with Xe and TMA mixture can be well characterized by ~3% fluorescence transfer from Xe to TMA, with further suppression due to TMA self-quenching. No evidence of the scintillation light produced by recombination of TMA ions was found. This strong suppression of scintillation light makes dark matter searches quite challenging, while the possibility of improved neutrinoless double beta decay searches remains open. Finally, this work has been carried out within the context of the NEXT collaboration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutrinoless double beta decay with 82 SeF 6 and direct ion imaging

Here, we present a new neutrinoless double beta decay concept: the high pressure selenium hexafluoride gas time projection chamber. A promising new detection technique is outlined which combines techniques pioneered in high pressure xenon gas, such as topological discrimination, with the high Q-value afforded by the double beta decay isotope 82 Se. The lack of free electrons in SeF6 mandates the use of an ion TPC. The microphysics of ion production and drift, which have many nuances, are explored. Background estimates are presented, suggesting that such a detector may achieve background indices of better than 1 count per ton per year in the region of interest at the 100 kg scale, and still better at the ton-scale.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Metallic wire grid behavior and testing in a low pressure gaseous noble elements detector

High voltage performance has been a challenge for noble element detectors. One piece of this challenge is the emission of electrons from metal electrodes when applying high voltage. This has become a major concern for low-background detectors such as LUX-ZEPLIN (LZ). LZ is a liquid xenon Time Projection Chamber (TPC) searching for Weakly Interactive Massive Particles (WIMPs). In this work, we demonstrate a method to measure electron emission from metallic electrode grids via detection of proportional scintillation light. As a result, we find consistency with Fowler-Nordheim emission with a surface parameter β = 1988 after electro-polishing treatment of a stainless steel grid.

47 OTHER INSTRUMENTATION↗

Ionization electron signal processing in single phase LArTPCs. Part II. Data/simulation comparison and performance in MicroBooNE

The single-phase liquid argon time projection chamber (LArTPC) provides a large amount of detailed information in the form of fine-grained drifted ionization charge from particle traces. To fully utilize this information, the deposited charge must be accurately extracted from the raw digitized waveforms via a robust signal processing chain. Enabled by the ultra-low noise levels associated with cryogenic electronics in the MicroBooNE detector, the precise extraction of ionization charge from the induction wire planes in a single-phase LArTPC is qualitatively demonstrated on MicroBooNE data with event display images, and quantitatively demonstrated via waveform-level and track-level metrics. Improved performance of induction plane calorimetry is demonstrated through the agreement of extracted ionization charge measurements across different wire planes for various event topologies. In addition to the comprehensive waveform-level comparison of data and simulation, a calibration of the cryogenic electronics response is presented and solutions to various MicroBooNE-specific TPC issues are discussed. This work presents an important improvement in LArTPC signal processing, the foundation of reconstruction and therefore physics analyses in MicroBooNE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial results on energy resolution of the NEXT-White detector

One of the major goals of the NEXT-White (NEW) detector is to demonstrate the energy resolution that an electroluminescent high pressure xenon TPC can achieve for high energy tracks. For this purpose, energy calibrations with 137Cs and 232Th sources have been carried out as a part of the long run taken with the detector during most of 2017. This paper describes the initial results obtained with those calibrations, showing excellent linearity and an energy resolution that extrapolates to approximately 1% FWHM at Q$_{\beta\beta}$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron drift and longitudinal diffusion in high pressure xenon-helium gas mixtures

We report new measurements of the drift velocity and longitudinal diffusion coefficients of electrons in pure xenon gas and in xenon-helium gas mixtures at 1-9 bar and electric field strengths of 50-300 V/cm. In pure xenon we find excellent agreement with world data at all E/P, for both drift velocity and diffusion coefficients. However, a larger value of the longitudinal diffusion coefficient than theoretical predictions is found at low E/P in pure xenon, below the range of reduced fields usually probed by TPC experiments. A similar effect is observed in xenon-helium gas mixtures at somewhat larger E/P. Drift velocities in xenon-helium mixtures are found to be theoretically well predicted. Although longitudinal diffusion in xenon-helium mixtures is found to be larger than anticipated, extrapolation based on the measured longitudinal diffusion coefficients suggest that the use of helium additives to reduce transverse diffusion in xenon gas remains a promising prospect.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Calorimetric Energy Reconstruction of Beam Events with ARAPUCA Light Detector in ProtoDUNE-SP

ProtoDUNE Single Phase at CERN is the large scale prototype for the far detector of the future DUNE experiment. ProtoDUNE is in stable operation since Oct. 2018 at the CERN Neutrino Platform. Test beam data in the energy range of sub-GeV to a few GeV were collected in fall 2018 providing a set of key measurements. Particles (electrons, protons, pions, muons and kaons) are identified combining information from a set of beam-line detectors (Time of Flight, Cherenkov) and TPC reconstruction. Three different technologies are implemented in the protoDUNE photon detector system (PDS). Results from the ARAPUCA response, one of the PDS components, are presented providing first calorimetric energy measurements and particle ID of beam events from LAr scintillation light signals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗