Search NASA⌕ Search

SEARCH · Search NASA

Results for “TRACE CONTAMINANT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Indicator Devices for Detection of Trace Gaseous Hydrazines

The relatively recent decrease in the acceptable time-weighted-average for hydrazines from 100 parts-per-billion (ppb) to 10 ppb rendered many trace hydrazine detectors either insensitive or inaccurate. Development of a rapid detection method for hydrazines at the new 10-ppb concentration was necessary so that test area personnel could reliably assess airborne hydrazines concentrations of a potentially contaminated area prior to entry. The reduction of Au(III) to Au(0) by hydrazines is a well characterized reaction and application of the corresponding yellow to purple color change was selected as a potentially useful means for detection of trace hydrazines in air. Tests with small quantities of KAuCl4 deposited on a variety of substrates were conducted using verified sources of 1,1-dimethylhydrazine, methylhydrazine, and hydrazine at approximately 10 ppb in air. Substrates tested were glass fiber filter paper, glass beads, anion exchange resin (AuCl4- form), and diatomaceous earth. The most successful of these substrates were glass fiber filter paper and diatomaceous earth. The KAuC14 impregnated glass fiber filter paper appeared to be somewhat light sensitive so further tests were conducted using the diatomaceous earth substrate. KAuCl4 concentration, substrate particle size, and sampler configuration were evaluated. Based on these tests, the device selected for further evaluation was a 5mm OD by 50mm glass tube containing 0.02-0.03g of 45/60 mesh diatomaceous earth coated with 2 percent KAuCl4. When connected to a sampling pump, response of the device to changes in relative humidity, ambient light, and high levels of other fluids, which might also be found in a propellant test area, was evaluated. False positive responses were not detected for exposures to relative humidity changes from 10 to 80 percent, sunlight for greater than 10 minutes, or percent levels of ammonia, isopropyl alcohol, nitrogen dioxide, and hydrogen. In addition, body emissions did not produce a false positive response in view of potential application for use inside protective clothing. The device was shown to reliably detect less than 10 ppb of the hydrazines tested using a 10 to 20L sample followed by a 2 to 5 minute color development time. Some field tests were conducted in parallel with conventional acidic firebrick sorbent tubes. There was generally very good agreement between the devices and firebrick sorbent tubes when greater than 10 ppb of a hydrazine was present.

Dee, Lou A.↗

Proper Criteria of Nonlinear Optical Crystals for Space Laser Systems and the Possible Causes for Space Laser Failures

NASA is striving to develop a scientific understanding of the universe and the Earth-Sun System and its response to natural or human-induced changes. Space lasers are vital tools for NASA's missions to advance our understanding of space research and improving our prediction capability for climate, weather, and natural hazards. Unfortunately, several past space missions that utilized lasers proved to be short-lived and unreliable. In this paper, we are reporting the results of our investigations on several nonlinear optical crystals, which are vital components in space lasers. Examples of these investigations are: The correlation of the phase diagrams of nonlinear crystals and its durability, the effect of radiating these crystals by high-energy beams of protons and gamma on their second harmonic efficiency, and measurements of the high-energy and low-energy thresholds for each crystal before and after irradiation. A set of proper criteria for these crystals will be presented. We will also discuss the possible causes of failures in a space laser and propose a solution to a contamination problem in all future space lasers.

Abdeldayem, Hossin A.↗

Measuring Moisture in Sealed Electronic Enclosures

Instrument checks trace amounts accurately. Moisture in hermeticallysealed electronic equipment measured by instrument designed for field use. Instrument also measures pressure, volume, and contaminants of gas in sealed enclosure. Plumbing for instrument uses vacuum-tight valves so any portion of instrument cleansed by opening certain valves to vacuum source. To ensure accuracy, manifolds are of minimal volume, each comprising only volume within cross-shaped tubing fittings.

Krieg, Herman C., Jr.↗

Planetary Protection, Sample Return Missions and Mars Exploration: History, Status, and Future Needs

As the prospect grows for a Mars sample return mission early in the next millennium, it will be important to ensure that appropriate planetary protection (PP) controls are incorporated into the mission design and implementation from the start. The need for these PP controls is firmly based on scientific considerations and backed by a number of national and international agreements and guidelines aimed at preventing harmful cross contamination of planets and extraterrestrial bodies. The historical precedent for the use of PP measures on both unmanned and manned missions traces from post-Sputnik missions to the present, with periodic modifications as new information was obtained. In consideration of the anticipated attention to PP questions by both the scientific/technical community and the public, this paper presents a comprehensive review of the major issues and problems surrounding PP for a Mars Sample Return (MSR) mission, including an analysis of arguments that have been raised for and against the imposition of PP measures. Also discussed are the history and foundations for PP policies and requirements; important research areas needing attention prior to defining detailed PP requirements for a MSR mission; and legal and public awareness issues that must be considered with mission planning.

DeVincenzi, Donald L.↗

Planetary Protection, Sample Return Missions and Mars Exploration: History, Status, and Future Needs

As the prospect grows for a Mars sample return mission early in the next millennium, it will be important to ensure that appropriate planetary protection (PP) controls are incorporated into the mission design and implementation from the start. The need for these PP controls is firmly based on scientific considerations and backed by a number of national and international agreements and guidelines aimed at preventing harmful cross contamination of planets and extraterrestrial bodies. The historical precedent for the use of PP measures on both unmanned and manned missions traces from post-Sputnik missions to the present, with periodic modifications as new information was obtained. In consideration of the anticipated attention to PP questions by both the scientific/technical community and the public, this paper presents a comprehensive review of the major issues and problems surrounding PP for a Mars Sample Return (MSR) mission, including an analysis of arguments that have been raised for and against the imposition of PP measures. Also discussed are the history and foundations for PP policies and requirements; important research areas needing attention prior to defining detailed PP requirements for a MSR mission; and legal and public awareness issues that must be considered with mission planning.

DeVincenzi, Donald L.↗

Trace Gas Monitoring

Space technology is contributing to air pollution control primarily through improved detectors and analysis methods. Miniaturized mass spectrometer is under development to monitor vinyl chloride and other hydrocarbon contaminants in an airborne laboratory. Miniaturized mass spectrometer can be used to protect personnel in naval and medical operations as well as aboard aircraft.

Source record↗

Timescale of Petrogenetic Processes Recorded in the Mount Perkins Magma System, Northern Colorado River Extension Corridor, Arizona

The Miocene Mt. Perkins Pluton is a small composite intrusive body emplaced in the shallow crust as four separate phases during the earliest stages of crustal extension. Phase 1 (oldest) consists of isotropic hornblende gabbro and a layered cumulate sequence. Phase 2 consists of quartz monzonite to quartz monzodiorite hosting mafic microgranitoid enclaves. Phase 3 is composed of quartz monzonite and is subdivided into mafic enclave-rich zones and enclave-free zones. Phase 4 consists of aphanitic dikes of mafic, intermediate and felsic compositions hosting mafic enclaves. Phases 2-4 enclaves record significant isotopic disequilibrium with surrounding granitoid host rocks, but collectively enclaves and host rocks form a cogenetic suite exhibiting systematic variations in Nd-Sr-Pb isotopes that correlate with major and trace elements. Phases 2-4 record multiple episodes of magma mingling among cogenetic hybrid magmas that formed via magma mixing and fractional crystallization at a deeper crustal. The mafic end-member was alkali basalt similar to nearby 6-4 Ma basalt with enriched OIB-like trace elements and Nd-Sr-Pb isotopes. The felsic end-member was a subalkaline crustal-derived magma. Phase 1 isotropic gabbro exhibits elemental and isotopic compositional variations at relatively constant SiO2, suggesting generation of isotropic gabbro by an open-system process involving two mafic end-members. One end-member is similar in composition to the OIB-like mafic end-member for phases 2-4; the second is similar to nearby 11-8 Ma tholeiite basalt exhibiting low epsilon (sub Nd), and depleted incompatible trace elements. Phase 1 cumulates record in situ fractional crystallization of an OIB-like mafic magma with isotopic evidence of crustal contamination by partial melts generated in adjacent Proterozoic gneiss. The Mt Perkins pluton records a complex history in a lithospheric scale magma system involving two distinct mantle-derived mafic magmas and felsic magma sourced in the crust. Mixing and fractional crystallization of these magmas at various levels in the crust generated a suite of intermediate composition magmas. U-Pb zircon SHRIMP ages of phase 1 (15.7 +/- 0.2 Ma), phase 3 (15.8 +/- 0.2 Ma) and phase 4 (15.4 +/- 0.3 Ma) document a 100-300k year timescale for petrogenetic processes recorded in the Mt Perkins magma system.

Danielson, Lisa R.↗

Bunburra Rockhole: Exploring the Geology of a New Differentiated Basaltic Asteroid

Bunburra Rockhole (BR) is the first recovered meteorite of the Desert Fireball Network. It was initially classified as a basaltic eucrite, based on texture, mineralogy, and mineral chemistry but subsequent O isotopic analyses showed that BR's composition lies significantly far away from the HED group of meteorites. This suggested that BR was not a piece of the HED parent body (4 Vesta), but other explanations could also account for the observed oxygen signatures. Possible scenarios include contamination by components from other bodies (chondrites or other achondrites) or that 4 Vesta may not be as equilibrated as hypothesized. After examining multiple pieces with different instruments (CT scans and x-ray maps), no obvious evidence of contamination was found. If BR is not from Vesta, a conundrum exists as no unusual features were found in mineral and bulk trace element chemistry as exist for other anomalous basaltic achondrites such as Ibitira or Asuka 881394. These meteorites have distinct petrological and geochemical characteristics, in addition to their anomalous O isotope compositions, that set them apart from eucrites. Thus, early results provided a somewhat ambiguous picture of BR's petrogenesis and parentage. To clarify the nature of the relationship, if any, between BR and eucrites, we have performed a correlated stable isotope and bulk chemical study of several lithologic fragments.

Benedix, G.K.↗

Determination of points of entry for potential contaminants into limestone aquifers using thermal infrared imagery

Lineations were identified involving the application of ERTS imagery to geologic and hydrologic problems. Interpretation of the southwest Madison County area is discussed. The tracing of the Beech Grove lineament to the northern boundary of Madison County, Alabama raises the question of its relationship to the trend of lineations in southwestern Madison County. The use of thermography as an indication of soil moisture is reviewed. The effect of soil moisture on surface temperature and the relationship between soil moisture and ground water are examined.

Doyle, F. L.↗

Extraterrestrial Amino Acids and Amines Identified in Asteroid Ryugu Samples Returned By the Hayabusa2 Mission

The hot water and acid extracts of two different Ryugu samples collected by the Hayabusa2 mission were analyzed for the presence of aliphatic amines and amino acids. The abundances and relative distributions of both classes of molecules were determined, as well as the enantiomeric compositions of the chiral amino acids. The Ryugu samples studied here were recovered from sample chambers A and C, which were composed of surface material, and a combination of surface and possible subsurface material, respectively. A total of thirteen amino acids were detected and quantitated in these samples, with an additional five amino acids that were tentatively identified but not quantitated. The abundances of four aliphatic amines identified in the Ryugu samples were also determined in the current work. Amino acids were observed in the acid hydrolyzed and unhydrolyzed hot water extracts of asteroid Ryugu regolith using liquid chromatography with UV fluorescence detection and high-resolution mass spectrometry. Conversely, aliphatic amines were only analyzed in the unhydrolyzed hot water Ryugu extracts. Two- to six-carbon (C 2 -C 6 ) amino acids with individual abundances ranging from 0.02 to 15.8 nmol g −1 , and one- to three-carbon (C 1 -C 3 ) aliphatic amines with individual abundances from 0.05 to 34.14 nmol g −1 , were found in the hot water extracts. Several non-protein amino acids that are rare in biology, including β-amino-n-butyric acid (β-ABA) and β-aminoisobuytric acid (β-AIB), were racemic or very nearly racemic, thus indicating their likely abiotic origins. Trace amounts of select protein amino acids that were enriched in the ւ-enantiomer may indicate low levels of terrestrial amino acid contamination in the samples. However, the presence of elevated abundances of free and racemic alanine, a common protein amino acid in terrestrial biology, and elevated abundances of the predominately free and racemic non-protein amino acids, β-ABA and β-AIB, indicate that many of the amino acids detected in the Ryugu water extracts were indigenous to the samples. Although the Ryugu samples have been found to be chemically similar to CI type carbonaceous chondrites, the measured concentrations and relative distributions of amino acids and aliphatic amines in Ryugu samples were notably different from those previously observed for the CI1.1 carbonaceous chondrite, Orgueil. This discrepancy could be the result of differences in the original chemical compositions of the parent bodies and/or alteration conditions, such as space weathering. In addition to α-amino acids that could have been formed by Strecker cyanohydrin synthesis during a low temperature aqueous alteration phase, β-, γ-, and δ-amino acids, including C 3 – C 5 straight-chain n-ω-amino acids that are not formed by Strecker synthesis, were also observed in the Ryugu extracts. The suite of amino acids measured in the Ryugu samples indicates that multiple amino acid formation mechanisms were active on the Ryugu parent body. The analytical techniques used here are well-suited to search for similar analytes in asteroid Bennu material collected by the NASA OSIRIS-REx mission scheduled for Earth return in September 2023.

Hayabusa2↗

Reactivity of stratospheric aerosols to small amounts of ammonia in the laboratory environment

Trace ammonia in laboratory air reacts easily with sulfuric acid aerosol samples to form crystalline ammonium sulfate. Argon atmospheres, however, protect sampling surfaces from ammonia contamination. It is found that atmospheric aerosols treated in this way contain only sulfuric acid. After an hour exposed to laboratory air, these same samples convert to ammonium sulfate. Aerosol particles have been collected, using argon control, to determine if the absence of crystalline sulfate is common. But so far there is no evidence that aerosols are neutralized by ammonia in the stratosphere.

Hayes, D.↗

Analysis of minerals containing dissolved traces of the fluid phase components water and carbon dioxide

Substantial progress has been made towards a better understanding of the dissolution of common gas/fluid phase components, notably H2O and CO2, in minerals. It has been shown that the dissolution mechanisms are significantly more complex than currently believed. By judiciously combining various solid state analytical techniques, convincing evidence was obtained that traces of dissolved gas/fluid phase components undergo, at least in part, a redox conversion by which they split into reduced H2 and and reduced C on one hand and oxidized oxygen, O(-), on the other. Analysis for 2 and C as well as for any organic molecules which may form during the process of co-segregation are still impeded by the omnipresent danger of extraneous contamination. However, the presence of O(-), an unusual oxidized form of oxygen, has been proven beyond a reasonable doubt. The presence of O(-) testifies to the fact that a redox reaction must have taken place in the solid state involving the dissolved traces of gas/fluid phase components. Detailed information on the techniques used and the results obtained are given.

Freund, Friedemann↗

Partial performance degradation of a remote sensor in a space environment, and some probable causes

The Multispectral Scanner (MSS) was launched on the Earth Resources Technology Satellite (ERTS-1) on July 23, 1972. The MSS has two calibration systems, one internal and one external. Both calibration systems have shown strong, spectrally dependent performance degradation since launch. This paper presents details on the optical system of the MSS and data on the performance degradation as a function of both spectral interval and time in orbit. The history of the MSS during tests is traced, and it is shown that hydrocarbons from an external source may have been deposited on optical surfaces in the instrument. It is postulated that these contaminant coatings may have polymerized as a result of the exposure to UV light from the sun, increasing their blue absorbtion and accounting for the observed performance degradation.

Horan, J. J.↗

Evaluation of crustal recycling during the evolution of Archean-age Matachewan basaltic magmas

The simplest model for the Matachewan-Hearst Dike (MHD) magmas is assimilation-fractional crystallization (AFC), presumably occurring at the base of the crust during underplating. Subduction zone enriched mantle sources are not required. Trace elements suggest that the mantle sources for the MHD were depleted, but possessed a degree of heterogeneity. Rates of assimilation were approximately 0.5 (= Ma/Mc); the contaminant mass was less than 20 percent. The contaminant was dominated by tonalites-randodiorites, similar to xenoliths and rocks in the Kapuskasing Structural Zone (KSZ). Assimilation of partial melts of light-rare earth and garnet-bearing basaltic precursors may have produced some the MHD magmas. Apparently, previous underplating-AFC processes had already produced a thick crust. The silicic granitoid assimilant for the MHD magmas was probably produced by earlier processing of underplated mafic crust (4, 5, 10, 21 and 30). Calculations suggest that the derived silicic rocks possess negative Ta and Ti anomalies even though they were not the product of subduction.

Nelson, Dennis O.↗

Sidelobe Modeling and Mitigation for A Three Mirror Anastigmat Cosmic Microwave Background Telescope

Telescopes measuring cosmic microwave background (CMB) polarization on large angular scales require exquisite control of systematic errors to ensure the fidelity of the cosmological results. In particular, far-sidelobe contamination from wide angle scattering is a potentially prominent source of systematic error for large aperture microwave telescopes. Here we describe and demonstrate a ray-tracing-based modeling technique to predict far sidelobes for a three mirror anastigmat telescope designed to observe the CMB from the South Pole. Those sidelobes are produced by light scattered in the receiver optics subsequently interacting with the walls of the surrounding telescope enclosure. After comparing simulated sidelobe maps and angular power spectra for different enclosure wall treatments, we propose a highly scattering surface that would provide more than an order of magnitude reduction in the degree-scale far-sidelobe contrast compared to a typical reflective surface. We conclude by discussing the fabrication of a prototype scattering wall panel and presenting measurements of its angular scattering profile.

Ian Gullett↗

Laser absorption spectroscopy - Method for monitoring complex trace gas mixtures

A frequency stabilized CO2 laser was used for accurate determinations of the absorption coefficients of various gases in the wavelength region from 9 to 11 microns. The gases investigated were representative of the types of contaminants expected to build up in recycled atmospheres. These absorption coefficients were then used in determining the presence and amount of the gases in prepared mixtures. The effect of interferences on the minimum detectable concentration of the gases was measured. The accuracies of various methods of solution were also evaluated.

Green, B. D.↗

Viewer Makes Radioactivity "Visible"

Battery operated viewer demonstrates feasibility of generating threedimensional visible light simulations of objects that emit X-ray or gamma rays. Ray paths are traced for two pinhold positions to show location of reconstructed image. Images formed by pinholes are converted to intensified visible-light images. Applications range from radioactivity contamination surveys to monitoring radioisotope absorption in tumors.

Yin, L. I.↗

Understanding Sampling Hardware Cleanliness from Perseverance Lessons Learned, and Forward Approach to Biosignature Missions

The search for biosignatures on other solar system bodies drives the scientific objectives of many ongoing and proposed exploration missions, including the Europa Lander mission concept.[1] The detection of trace and unfamiliar biosignatures in extreme environments necessitates state-of-the-art scientific instrumentation with extraordinary sensitivity – and often, extraordinary susceptibility to terrestrial and spacecraft self-induced contamination vectors.[2] While instruments can be carefully designed to operate remotely at high performance, in situ scientific measurements can only analyze the samples they’re given: samples or sample handling hardware that have been inadvertently tainted by outgassed organic molecules, thruster plume effluents, or other common sources of spacecraft contamination may yield ambiguous or false results. Maintaining and verifying the purity of collected samples and the cleanliness of sample handling hardware throughout the lifecycle of biosignature detection missions like Europa Lander is a primary responsibility of the Contamination Control group at JPL.

Alred, John↗