Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tabulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Addressing trend-related changes within cumulative effects studies in water resources planning

Summarized herein are 28 case studies wherein trend-related causative physical, social, or institutional changes were connected to consequential changes in runoff, water quality, and riparian and aquatic ecological features. The reviewed cases were systematically evaluated relative to their identified environmental effects; usage of analytical frameworks, and appropriate models, methods, and technologies; and the attention given to mitigation and/or management of the resultant causative and consequential changes. These changes also represent important considerations in project design and operation, and in cumulative effects studies associated therewith. The cases were grouped into five categories: institutional changes associated with legislation and policies (seven cases); physical changes from land use changes in urbanizing watersheds (eight cases); physical changes from land use changes and development projects in watersheds (four cases); physical, institutional, and social changes from land use and related policy changes in river basins (three cases); and multiple changes within a comprehensive study of land use and policy changes in the Willamette River Basin in Oregon (six cases). A tabulation of 110 models, methods and technologies used in the studies is also presented. General observations from this review were that the features were unique for each case; the consequential changes were logically based on the causative changes; the analytical frameworks provided relevant structures for the studies, and the identified methods and technologies were pertinent for addressing both the causative and consequential changes. One key lesson was that the cases provide useful, “real-world” illustrations of the importance of addressing trend-related changes in cumulative effects studies within water resources planning. Accordingly, they could be used as an “initial tool kit” for addressing trend-related changes.

54 ENVIRONMENTAL SCIENCES↗

Daylight simulation workflows incorporating measured bidirectional scattering distribution functions

Daylight predictions of architectural spaces depend on good estimates of light transfer through skylights, windows and other fenestration systems. For clear glazing and painted surfaces, parametric transmission and reflection models have proven adequate, but there are many cases where light-scattering, semi-specular shading and daylighting materials defy simple characterization. Something as commonplace as fabric roller shades and venetian blinds may turn daylight prediction into guesswork, and numerous advanced systems on the market tuned specifically to enhance daylight are not sufficiently characterized to distinguish their performance. In this paper, we describe new tools available to handle novel and specialized fabrics, materials, and devices using data-driven modelling of bi-directional scattering distribution functions (BSDFs). These representations are usually tabulated at constant or adjustable angular resolution for efficient point-in-time and annual daylight simulations. We describe a variety of BSDF simulation workflows, including some of the tools and methods that make advanced analysis possible, and highlight some of the current challenges. We conclude with a discussion of future work and how such data might be created and shared worldwide.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field validation of data-driven BSDF and peak extraction models for light-scattering fabric shades

Shading and daylighting systems affect cooling, heating, and lighting energy use by modulating solar radiation through the building façade. Characterizing shading systems holistically and accurately helps designers and engineers evaluate shading systems to achieve energy and non-energy performance goals. These complex fenestration systems can be modeled using Bidirectional Scattering Distribution Functions (BSDF), which map incident radiation to hemispherical distributions of outgoing radiation. Data-driven, tabulated BSDFs are derived from interpolated goniophotometer measured data, then sampled during the raytracing calculation. A peak extraction (PE) algorithm was developed to circumvent limits in BSDF angular resolution, where the specular peak is extracted during simulation by evaluating the BSDF in the through direction and surrounding region. The objective of this study was to validate this measurement and modeling workflow using field monitored data from a full scale testbed with eleven installed fabrics of different weaves, openness factors, and colors and assess the accuracy of the workflow under different adaptation and contrast conditions. Test conditions were limited to clear sky conditions with the sun in the field of view. Results showed that, for tensor tree datasets, vertical illuminance, solar luminance (2.5° apex), and daylight glare probability (DGP) were predicted to within a mean bias error (MBE) error of -456 lx (-12.3%), -3.46e5 (-38.4%), and -0.042 (-7.8%) when full PE occurred. With a binary classification of glare/ no glare, DGP was predicted accurately with a true positive rate of 0.98 and true negative rate of 1.0 using tensor tree data and less accurately with Klems BSDF data, particularly for cases of no glare. The workflow may be of insufficient accuracy to distinguish borderline performance between fabrics using the four-point glare scale, particularly under low adaptation, high contrast daylit conditions. Errors were due to reductions in peak shape and intensity across the BSDF interpolation and data reduction workflow. Future work is needed to better preserve measurement fidelity during interpolation and sampling, which in turn will improve PE performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydrothermal solution calorimetry in acidic aqueous solutions and revisiting the standard partial molal thermodynamic properties of Nd 3+ from 25 to 300 °C

The mobility of rare earth elements (REE) can be predicted in aqueous fluids using geochemical modeling but the accuracy of these models strongly depends on the availability of robust thermodynamic properties for the REE aqueous species. The REE 3+ aqua ions are important in the derivation of the formation constants of all the major REE complexes including the chloride, sulfate, and fluoride species which predominate in many hydrothermal-magmatic systems. However, the thermodynamic properties of the REE 3+ aqua ions are still commonly derived from the Helgeson-Kirkham-Flowers (HKF) equation of state parameters tabulated several decades ago. The standard state thermodynamic properties at reference conditions (25 °C and 1bar) and their extrapolations to high temperature need to be verified, if not revised, based on hydrothermal experiments. In this study, the enthalpy of solution was measured for synthetic Nd hydroxide from 25 to 150 ºC to retrieve the standard partial molal thermodynamic properties of Nd 3+ as a function of temperature. The experiments were conducted in aqueous perchloric acid based solutions with starting pH of 2 and varying ionic strength (0.01 to 0.09 mol/kg NaClO 4 ). The standard partial molal enthalpy of formation (Δ f H°) of Nd 3+ derived from the experimental study displays differences of up to 10 kJ/mol compared to the enthalpy values derived from the HKF equation of state in the studied temperature range. These inaccuracies are resolved by adjusting the standard partial molal Gibbs energy of formation (Δ f G°) of Nd 3+ at 25 °C and 1 bar from -672.0 to -679.7 kJ/mol. The heat capacity function (C p °) derived between 25 and 150 ºC can be described by: C p ° = a 0 + a 1 ·T + a 2 ·T -2 , with a 0 = 1256, a 1 = -2.68, a 2 = -55.56·10 6 and T in Kelvin. A set of recommended thermodynamic properties is provided for the Nd 3+ aqua ions and corrections are provided for the chloride and fluoride species to remain internally consistent with the experimentally derived properties. These results allow predicting accurately the solubility of monazite between 25 and 300 ºC. Before these corrections, the properties for the Nd 3+ aqua ions derived from the HKF parameters resulted in up to ~1.5 orders of magnitude lower monazite solubility than determined experimentally. Here, a revision of the REE +3 aqua ions properties is necessary to accurately predict the mobility of REE in hydrothermal acidic solutions.

58 GEOSCIENCES↗

Parameterizing hot electron energy distributions for tabular emissivities and opacities

Cold Kα and Kβ emission spectroscopy is a powerful diagnostic for plasma conditions and distributions of energetic electrons produced in short pulse laser experiments. SPECT3D post-processes hydrodynamics code output and simulates high-resolution spectra and images for plasmas containing arbitrary distributions of hot electrons, however these calculations can become prohibitively expensive for plasmas requiring complex atomic data and detailed computational grids. To significantly increase calculation speed, it is desirable to use pre-configured opacity tables that include information about hot electrons, rather than calculating emissivity and opacity for every grid point by solving collisional-radiative atomic kinetic rate equations. However, to tabulate such opacities, a general parameter-based description of hot electron energy distributions must be found. To be practical, hot electrons should be represented with an analytic function of just a few parameters which, in addition to temperature and density, can be used to define parameter space for opacity tables. In this paper, we present a method that allows for describing a set of arbitrary binned hot electron distributions with a simple analytic function, with only a modest impact on the accuracy of the simulations. Increased calculation speeds of 50–100x are demonstrated. In conclusion, we also discuss details of opacity calculations and present synthetic spectroscopy data based on post-processing of detailed particle-in-cell simulations relevant to the ongoing experimental campaign at the Omega EP laser facility.

74 ATOMIC AND MOLECULAR PHYSICS↗

Thermo-physical properties of diamond nanofluids: A review

Nanofluids give ample opportunities to enhance the efficiency of thermal systems by improving the thermal properties of the host fluids. Because of its exceptional thermal, mechanical and electrical properties, diamond has attracted attention for use as a nanoparticle in fluids. Thereby, nanofluids have proven to be useful in applications, especially electronic cooling, where increasing thermal properties and avoiding electrical conductivity are vital. There have been numerous investigations of nanodiamond-nanofluid systems with many suggesting that considerable property enhancements, e.g., increased thermal conductivity, might be possible. Yet, those results have not been collectively compared or discussed. This paper reviews and summarizes the experimental values of the physical and thermal properties, including an appropriate focus on the thermal conductivity enhancement, of nanodiamond-nanofluid systems found in the literature as well as different techniques for thermal conductivity measurement. The effect of various factors on the thermal-physical properties of diamond nanofluids is also reviewed, and the stability and viscosity of diamond nanofluids are tabulated and compared. The preparation and properties of hybrid nanofluids containing diamond nanoparticles are analyzed and discussed in detail, and a list of potential uses for these enhanced heat transfer fluids in industrial and commercial applications is provided and deliberated.

36 MATERIALS SCIENCE↗

Quantification of Motion of Different Thoracic Locations Using Four-Dimensional Computed Tomography: Implications for Radiotherapy Planning

Purpose: To assess the respiratory motion of different thoracic nodal locations and its dependence on the presence of enlarged nodes; to assess the respiratory motion of different parenchymal tumor locations; and to determine the appropriate margins to cover the respiratory motion of targets at these locations. Methods and Materials: We reviewed the four-dimensional computed tomography scans of 20 patients with thoracic tumors treated at our institution. The motion of four central thoracic locations (aortic arch, carina, and bilateral hila), parenchymal tumor locations (upper vs. lower, and anterior vs. middle vs. posterior thorax), and bilateral diaphragmatic domes was measured. Results: For the central thoracic locations, the largest motion was in the superoinferior (SI) dimension (>5 mm for bilateral hila and carina, but <4 mm for aortic arch). No significant difference was found in the motion of these locations in the absence or presence of enlarged nodes. For parenchymal tumors, upper tumors exhibited smaller SI motion than did lower tumors (3.7 vs. 10.4 mm, p = 0.029). Similarly, anterior tumors exhibited smaller motion than did posterior tumors in both the SI (4.0 vs. 8.0 mm, p = 0.013) and lateral (2.8 vs. 4.6 mm, p = 0.045) directions. The margins that would be needed to encompass the respiratory motion of each of the evaluated locations in 95% of patients were tabulated and range from 3.4 to 37.2 mm, depending on the location and direction. Conclusions: The results of our study have provided data for appropriate site-specific internal target volume expansion that could be useful in the absence of four-dimensional computed tomography-based treatment planning. However, generalizing the results from a small patient population requires discretion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Safety in a Radiation Oncology Setting Using Failure Mode and Effects Analysis

Purpose: Failure mode and effects analysis (FMEA) is a widely used tool for prospectively evaluating safety and reliability. We report our experiences in applying FMEA in the setting of radiation oncology. Methods and Materials: We performed an FMEA analysis for our external beam radiation therapy service, which consisted of the following tasks: (1) create a visual map of the process, (2) identify possible failure modes; assign risk probability numbers (RPN) to each failure mode based on tabulated scores for the severity, frequency of occurrence, and detectability, each on a scale of 1 to 10; and (3) identify improvements that are both feasible and effective. The RPN scores can span a range of 1 to 1000, with higher scores indicating the relative importance of a given failure mode. Results: Our process map consisted of 269 different nodes. We identified 127 possible failure modes with RPN scores ranging from 2 to 160. Fifteen of the top-ranked failure modes were considered for process improvements, representing RPN scores of 75 and more. These specific improvement suggestions were incorporated into our practice with a review and implementation by each department team responsible for the process. Conclusions: The FMEA technique provides a systematic method for finding vulnerabilities in a process before they result in an error. The FMEA framework can naturally incorporate further quantification and monitoring. A general-use system for incident and near miss reporting would be useful in this regard.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sensitivity Analysis of Parameters in Linear-Quadratic Radiobiologic Modeling

Purpose: Radiobiologic modeling is increasingly used to estimate the effects of altered treatment plans, especially for dose escalation. The present article shows how much the linear-quadratic (LQ) (calculated biologically equivalent dose [BED] varies when individual parameters of the LQ formula are varied by {+-}20% and by 1%. Methods: Equivalent total doses (EQD2 = normalized total doses (NTD) in 2-Gy fractions for tumor control, acute mucosal reactions, and late complications were calculated using the linear- quadratic formula with overall time: BED = nd (1 + d/ [{alpha}/{beta}]) - log{sub e}2 (T - Tk) / {alpha}Tp, where BED is BED = total dose x relative effectiveness (RE = nd (1 + d/ [{alpha}/{beta}]). Each of the five biologic parameters in turn was altered by {+-}10%, and the altered EQD2s tabulated; the difference was finally divided by 20. EQD2 or NTD is obtained by dividing BED by the RE for 2-Gy fractions, using the appropriate {alpha}/{beta} ratio. Results: Variations in tumor and acute mucosal EQD ranged from 0.1% to 0.45% per 1% change in each parameter for conventional schedules, the largest variation being caused by overall time. Variations in 'late' EQD were 0.4% to 0.6% per 1% change in the only biologic parameter, the {alpha}/{beta} ratio. For stereotactic body radiotherapy schedules, variations were larger, up to 0.6 to 0.9 for tumor and 1.6% to 1.9% for late, per 1% change in parameter. Conclusions: Robustness occurs similar to that of equivalent uniform dose (EUD), for the same reasons. Total dose, dose per fraction, and dose-rate cause their major effects, as well known.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Biological in situ Dose Painting for Image-Guided Radiation Therapy Using Drug-Loaded Implantable Devices

Purpose: Implantable devices routinely used for increasing spatial accuracy in modern image-guided radiation treatments (IGRT), such as fiducials or brachytherapy spacers, encompass the potential for in situ release of biologically active drugs, providing an opportunity to enhance the therapeutic ratio. We model this new approach for two types of treatment. Methods and Materials: Radiopaque fiducials used in IGRT, or prostate brachytherapy spacers ('eluters'), were assumed to be loaded with radiosensitizer for in situ drug slow release. An analytic function describing the concentration of radiosensitizer versus distance from eluters, depending on diffusion-elimination properties of the drug in tissue, was developed. Tumor coverage by the drug was modeled for tumors typical of lung stereotactic body radiation therapy treatments for various eluter dimensions and drug properties. Six prostate {sup 125}I brachytherapy cases were analyzed by assuming implantation of drug-loaded spacers. Radiosensitizer-induced subvolume boost was simulated from which biologically effective doses for typical radiosensitizers were calculated in one example. Results: Drug distributions from three-dimensional arrangements of drug eluters versus eluter size and drug properties were tabulated. Four radiosensitizer-loaded fiducials provide adequate radiosensitization for {approx}4-cm-diameter lung tumors, thus potentially boosting biologically equivalent doses in centrally located stereotactic body treated lesions. Similarly, multiple drug-loaded spacers provide prostate brachytherapy with flexible shaping of 'biologically equivalent doses' to fit requirements difficult to meet by using radiation alone, e.g., boosting a high-risk region juxtaposed to the urethra while respecting normal tissue tolerance of both the urethra and the rectum. Conclusions: Drug loading of implantable devices routinely used in IGRT provides new opportunities for therapy modulation via biological in situ dose painting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modified COMS Plaques for {sup 125}I and {sup 103}Pd Iris Melanoma Brachytherapy

Purpose: Novel plaques are used to treat iris melanoma at the Mayo Clinic Rochester. The plaques are a modification of the Collaborative Ocular Melanoma Study (COMS) 22 mm plaque design with a gold alloy backing, outer lip, and silicone polymer insert. An inner lip surrounds a 10 mm diameter cutout region at the plaque center. Plaques span 360{sup o}, 270{sup o}, and 180{sup o} arcs. This article describes dosimetry for these plaques and others used in the treatment of anterior eye melanomas. Methods and Materials: The EGSnrc user-code BrachyDose is used to perform Monte Carlo simulations. Plaques and seeds are fully modeled. Three-dimensional dose distributions for different plaque models, TG-43 calculations, and {sup 125}I (model 6711) and {sup 103}Pd (model 200) seeds are compared via depth-dose curves, tabulation of doses at points of interest, and isodose contours. Results: Doses at points of interest differ by up to 70% from TG-43 calculations. The inner lip reduces corneal doses. Matching plaque arc length to tumor extent reduces doses to eye regions outside the treatment area. Maintaining the same prescription dose, {sup 103}Pd offers lower doses to critical structures than {sup 125}I, with the exception of the sclera adjacent to the plaque. Conclusion: The Mayo Clinic plaques offer several advantages for anterior eye tumor treatments. Doses to regions outside the treatment area are significantly reduced. Doses differ considerably from TG-43 predictions, illustrating the importance of complete Monte Carlo simulations. Calculations take a few minutes on a single CPU, making BrachyDose sufficiently fast for routine clinical treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Radiotherapy for Head-and-Neck Cancer: Initial Clinical Outcomes From a Prospective Trial

Purpose: To present pilot toxicity and survival outcomes for a prospective trial investigating adaptive radiotherapy (ART) for oropharyngeal squamous cell carcinoma. Methods and Materials: A total of 24 patients were enrolled in an institutional review board-approved clinical trial; data for 22 of these patients were analyzed. Daily CT-guided setup and deformable image registration permitted serial mapping of clinical target volumes and avoidance structures for ART planning. Primary site was base of tongue in 15 patients, tonsil in 6 patient, and glossopharyngeal sulcus in 1 patient. Twenty patients (91%) had American Joint Committee on Cancer (AJCC) Stage IV disease. T stage distribution was 2 T1, 12 T2, 3 T3, 5 T4. N stage distribution was 1 N0, 2 N1, 5 N2a, 12 N2b, and 2 N2c. Of the patients, 21 (95%) received systemic therapy. Results: With a 31-month median follow-up (range, 13-45 months), there has been no primary site failure and 1 nodal relapse, yielding 100% local and 95% regional disease control at 2 years. Baseline tumor size correlated with absolute volumetric treatment response (p = 0.018). Parotid volumetric change correlated with duration of feeding tube placement (p = 0.025). Acute toxicity was comparable to that observed with conventional intensity-modulated radiotherapy (IMRT). Chronic toxicity and functional outcomes beyond 1 year were tabulated. Conclusion: This is the first prospective evaluation of morbidity and survival outcomes in patients with locally advanced head-and-neck cancer treated with automated adaptive replanning. ART can provide dosimetric benefit with only one or two mid-treatment replanning events. Our preliminary clinical outcomes document functional recovery and preservation of disease control at 1-year follow-up and beyond.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-Time Tumor Tracking in the Lung Using an Electromagnetic Tracking System

Purpose: To describe the first use of the commercially available Calypso 4D Localization System in the lung. Methods and Materials: Under an institutional review board-approved protocol and an investigational device exemption from the US Food and Drug Administration, the Calypso system was used with nonclinical methods to acquire real-time 4-dimensional lung tumor tracks for 7 lung cancer patients. The aims of the study were to investigate (1) the potential for bronchoscopic implantation; (2) the stability of smooth-surface beacon transponders (transponders) after implantation; and (3) the ability to acquire tracking information within the lung. Electromagnetic tracking was not used for any clinical decision making and could only be performed before any radiation delivery in a research setting. All motion tracks for each patient were reviewed, and values of the average displacement, amplitude of motion, period, and associated correlation to a sinusoidal model (R{sup 2}) were tabulated for all 42 tracks. Results: For all 7 patients at least 1 transponder was successfully implanted. To assist in securing the transponder at the tumor site, it was necessary to implant a secondary fiducial for most transponders owing to the transponder's smooth surface. For 3 patients, insertion into the lung proved difficult, with only 1 transponder remaining fixed during implantation. One patient developed a pneumothorax after implantation of the secondary fiducial. Once implanted, 13 of 14 transponders remained stable within the lung and were successfully tracked with the tracking system. Conclusions: Our initial experience with electromagnetic guidance within the lung demonstrates that transponder implantation and tracking is achievable though not clinically available. This research investigation proved that lung tumor motion exhibits large variations from fraction to fraction within a single patient and that improvements to both transponder and tracking system are still necessary to create a clinical daily-use system to assist with actual lung radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early Toxicity in Patients Treated With Postoperative Proton Therapy for Locally Advanced Breast Cancer

Purpose: To report dosimetry and early toxicity data in breast cancer patients treated with postoperative proton radiation therapy. Methods and Materials: From March 2013 to April 2014, 30 patients with nonmetastatic breast cancer and no history of prior radiation were treated with proton therapy at a single proton center. Patient characteristics and dosimetry were obtained through chart review. Patients were seen weekly while on treatment, at 1 month after radiation therapy completion, and at 3- to 6-month intervals thereafter. Toxicity was scored using Common Terminology Criteria for Adverse Events version 4.0. Frequencies of toxicities were tabulated. Results: Median dose delivered was 50.4 Gy (relative biological equivalent [RBE]) in 5 weeks. Target volumes included the breast/chest wall and regional lymph nodes including the internal mammary lymph nodes (in 93%). No patients required a treatment break. Among patients with >3 months of follow-up (n=28), grade 2 dermatitis occurred in 20 patients (71.4%), with 8 (28.6%) experiencing moist desquamation. Grade 2 esophagitis occurred in 8 patients (28.6%). Grade 3 reconstructive complications occurred in 1 patient. The median planning target volume V95 was 96.43% (range, 79.39%-99.60%). The median mean heart dose was 0.88 Gy (RBE) [range, 0.01-3.20 Gy (RBE)] for all patients, and 1.00 Gy (RBE) among patients with left-sided tumors. The median V20 of the ipsilateral lung was 16.50% (range, 6.1%-30.3%). The median contralateral lung V5 was 0.34% (range, 0%-5.30%). The median maximal point dose to the esophagus was 45.65 Gy (RBE) [range, 0-65.4 Gy (RBE)]. The median contralateral breast mean dose was 0.29 Gy (RBE) [range, 0.03-3.50 Gy (RBE)]. Conclusions: Postoperative proton therapy is well tolerated, with acceptable rates of skin toxicity. Proton therapy favorably spares normal tissue without compromising target coverage. Further follow-up is necessary to assess for clinical outcomes and cardiopulmonary toxicities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multicenter Evaluation of the Tolerability of Combined Treatment With PD-1 and CTLA-4 Immune Checkpoint Inhibitors and Palliative Radiation Therapy

Purpose: To analyze immune-related adverse events (ir-AEs) in patients treated with radiation and immune checkpoint blockade. Methods and Materials: We retrospectively reviewed records from patients with metastatic non-small cell lung cancer, melanoma, or renal cell cancer who received at least 1 cycle of a CTLA-4 or PD-1 inhibitor and radiation. Immune-related adverse events, defined using Common Terminology Criteria for Adverse Events version 4.0, were tabulated in relation to treatment variables, and associations with sequencing and timing were assessed. Results: We identified 133 patients, of whom 28 received a CTLA-4 inhibitor alone, 88 received a PD-1 inhibitor alone, and 17 received both classes of inhibitors either sequentially (n=13) or concurrently (n=4). Fifty-six patients received radiation within 14 days of an immune checkpoint inhibitor. Forty-six patients experienced at least 1 ir-AE (34.6%). Patients receiving both CTLA-4 and PD-1 inhibitors experienced more any-grade ir-AEs as compared with either individually (71% vs 29%, P=.0008). Any-grade ir-AEs occurred in 39% of patients in whom radiation was administered within 14 days of immunotherapy, compared with 23% of other patients (P=.06) and more often in patients who received higher equivalent dose in 2-Gy fractions (EQD2) EQD2 (P=.01). However, most toxicities were mild. There were no associations between site irradiated and specific ir-AEs. Conclusions: Our data suggest the combination of focal palliative radiation and CTLA-4 and/or PD-1 inhibitors is well tolerated, with manageable ir-AEs that did not seem to be associated with the particular site irradiated. Although conclusions are limited by the heterogeneity of patients and treatments, and future confirmatory studies are needed, this information can help guide clinical practice for patients receiving immune checkpoint therapy who require palliative radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First principles screening of destabilized metal hydrides for high capacity H2 storage using scandium (presentation had varying title: Accelerating Development of Destabilized Metal Hydrides for Hydrogen Storage Using First Principles Calculations)

Favorable thermodynamics are a prerequisite for practical H2 storage materials for vehicular applications. Destabilization of metal hydrides is a versatile route to finding materials that reversibly store large quantities of H2. First principles calculations have proven to be a useful tool for screening large numbers of potential destabilization reactions when tabulated thermodynamic data are unavailable. We have used first principles calculations to screen potential destabilization schemes that involve Sc-containing compounds. Our calculations use a two-stage strategy in which reactions are initially assessed based on their reaction enthalpy alone, followed by more detailed free energy calculations for promising reactions. Our calculations indicate that mixtures of ScH2 + 2LiBH4, which will release 8.9 wt.% H2 at completion and will have an equilibrium pressure of 1 bar at around 330 K, making this compound a promising target for experimental study. Along with thermodynamics, favorable kinetics are also of enormous importance for practical usage of these materials. Experiments would help identify possible kinetic barriers and modify them by developing suitable catalysts.

08 HYDROGEN↗

Hard and semi-hard Fe-based magnetic materials

Iron (Fe) is the most important ferromagnetic element, not only for its high magnetic moment and high Curie temperature but for its abundance as well. Fe-based magnetic materials are therefore widely applied in technologies and industries, with most of the applications for soft magnetic materials, because of the low magnetocrystalline anisotropy (MCA) of Fe. However, it is possible to realize magnetic hardening in Fe-based materials as we have learned from the early carbon steel permanent magnets although their coercivity was modest. Recent efforts to search for rare-earth-free hard magnetic materials have shown more promising evidences for achieving high MCA in Fe-based materials. In this paper, we review the history and the recent developments of Fe-based hard and semi-hard magnetic materials with a focus on mechanisms of high MCA in Fe-based phases and the related crystal and electronic structures. Here, we have tabulated and discussed the structures and the magnetic properties of the Fe-based binary or ternary systems containing p-block and d-block elements, with many of them showing considerable MCA. Furthermore, it is important to know and to understand that the MCA in Fe-based magnetic materials can be tailored/enhanced through chemical and/or structural modifications that will lead to “artificially engineered” hard and semi-hard magnetic materials for advanced permanent magnets in the future.

36 MATERIALS SCIENCE↗

Recycling Glass Fiber Thermoplastic Composites from Wind Turbine Blades

We report that thermoplastic resin systems have long been discussed for use in large-scale composite parts but have yet to be exploited by the energy industry. The use of these resins versus their thermosetting counterparts can potentially introduce cost savings due to non-heated tooling, shorter manufacturing cycle times, and recovery of raw materials from the retired part. Because composite parts have high embedded energy, recovery of their constituent materials can provide substantial economic benefit. This study determines the feasibility of recycling composite wind turbine blade components that are fabricated with glass fiber reinforced Elium (R) thermoplastic resin. Several experiments are conducted to tabulate important material properties that are relevant to recycling, including thermal degradation, grinding, and dissolution of the polymer matrix to recover the constituent materials. Dissolution, which is a process unique to thermoplastic matrices, allows recovery of both the polymer matrix and full-length glass fibers, which maintain their stiffness (190 N/(mm g)) and strength (160 N/g) through the recovery process. Injection molded regrind material is stiffer (12 GPa compared to 10 GPa) and stronger (150 MPa compared to 84 MPa) than virgin material that had shorter fibers. An economic analysis of the technical data shows that recycling thermoplastic-glass fiber composites via dissolution into their constituent parts is commercially feasible under certain conditions. This analysis concludes that 50% of the glass fiber must be recovered and resold for a price of $0.28/kg. Furthermore, 90% of the resin must be recovered and resold at a price of $2.50/kg.

17 WIND ENERGY↗