Search NASA⌕ Search

SEARCH · Search NASA

Results for “Testing metrics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Results of investigations on a 0.010-scale model of the configuration 3 space shuttle orbiter and external tank in the NASA/Ames Research Center 3.5-foot hypersonic wind tunnel (IA15)

Experimental aerodynamic investigations were conducted in a 3.5-foot hypersonic wind tunnel. The model used for this test was a 0.010-scale of the Configuration 2 Space Shuttle Orbiter and the External Tank. Six-component aerodynamic force and moment data were recorded over an angle of attack range from -8 deg to +30 deg at 0 deg and 5 deg angles of sideslip. Data was also recorded during beta sweeps of -8 deg to +10 deg at angles of attack of -10 deg, 0 deg, and 30 deg. All testing was done at Mach 7.3. Various elevon, rudder and orbiter to external tank attaching structures and fairings were tested to determine longitudinal and lateral-directional stability characteristics. Non-metric exhaust plumes were installed during a portion of the testing to determine the effects of the main propulsion system rocket plumes.

Petrozzi, M. T.↗

Flight Validation of a Handling Qualities Metric for a Damaged Aircraft

Objectives: a) Develop an asymmetric handling qualities metric to predict cross coupling effects of a damaged aircraft: 1) Initial use of U.S Army Aeronautical Design Specification ADS-33; 2) Modification as required based on flight test results. b) Simulation and Flight Validation of proposed metric: 1) F-16 VISTA (March 2010); 2) F-18 Full Scale Test bed (Potential Early Experiment); and 3) Flight Simulators (GTM, ACFS, F-18 HILS). c) Provide flight validated metric and tool box to control law designers.

Cogan, Bruce R.↗

Fighter agility metrics

Fighter flying qualities and combat capabilities are currently measured and compared in terms relating to vehicle energy, angular rates and sustained acceleration. Criteria based on these measurable quantities have evolved over the past several decades and are routinely used to design aircraft structures, aerodynamics, propulsion and control systems. While these criteria, or metrics, have the advantage of being well understood, easily verified and repeatable during test, they tend to measure the steady state capability of the aircraft and not its ability to transition quickly from one state to another. Proposed new metrics to assess fighter aircraft agility are collected and analyzed. A framework for classification of these new agility metrics is developed and applied. A complete set of transient agility metrics is evaluated with a high fidelity, nonlinear F-18 simulation. Test techniques and data reduction methods are proposed. A method of providing cuing information to the pilot during flight test is discussed. The sensitivity of longitudinal and lateral agility metrics to deviations from the pilot cues is studied in detail. The metrics are shown to be largely insensitive to reasonable deviations from the nominal test pilot commands. Instrumentation required to quantify agility via flight test is also considered. With one exception, each of the proposed new metrics may be measured with instrumentation currently available.

Liefer, Randall K.↗

MS25: Materials Science-Focused Benchmark Data Set for Machine Learning Interatomic Potentials

Here, we present MS25, a benchmark data set for evaluating machine learning interatomic potentials (MLIPs) across diverse materials-relevant systems including MgO surfaces, liquid water, zeolites, a catalytic Pt surface reaction, high-entropy alloys (HEAs), and disordered Zr-oxides. Five MLIP architectures (MACE, NequIP, Allegro, MTP, and Torch-ANI) are trained and tested, focusing not only on traditional metrics (energies, forces, and stresses) but also explicitly validating derived physical observables such as lattice constants, volumes, and reaction barriers. We find that most models reach comparable accuracy on standard error metrics across the simple systems, although equivariant MLIPs offer 1.5–2× improvements over nonequivariant MLIPs in energy and force error for structurally complex or compositionally disordered environments such as HEAs and Zr–O systems. Our analysis highlights that low errors in energy and force predictions do not guarantee reliable observables, emphasizing the necessity of explicit validation. We demonstrate limitations in cross-framework transferability, as models trained on one zeolite framework (CHA) fail to reliably generalize to predictions of structurally distinct frameworks (e.g., MFI). Size-extensive tests show some dependence on system size for MgO, resulting from forced periodicity. The HEA and Zr–O data sets are identified as challenging tests for future benchmarks and MLIP model architecture developments as they show significant differentiation in error between MLIP architectures and are still relatively difficult at 1000 training images. Moving forward, we recommend that benchmarking efforts shift their focus from marginal accuracy improvements in energy and force errors toward identifying and understanding model failure modes, rigorously assessing transferability, and evaluating how their errors affect observable predictions. For researchers looking to choose an MLIP architecture, we suggest selecting equivariant MLIP architectures if the complexity of the system is a challenge. For simple materials problems, auxiliary features such as integration with molecular dynamics engines, trade-offs between computational data set generation cost vs MLIP inference speed, and framework integration may play a more important decision factor than small differences in error metrics that are unlikely to matter for production-level research.

chemical structure↗

Cesium Ion Exchange Testing Using a Three-Column System with Crystalline Silicotitanate and Hanford Tank Waste 241-AP-107

Washington River Protection Solutions (WRPS) is working to support early production of immobilized low-activity waste by feeding Hanford tank supernate from tank farms to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) facility. This goal incorporates the design of a Tank-Side Cesium Removal (TSCR) system, which in effect filters tank waste supernate and processes it through a cesium ion exchange medium to remove 137Cs. The 137Cs-depleted product is sent to the WTP for vitrification. Rovira et al. (2018) reported the successful Cs removal from Hanford tank 241-AP-107 waste (hereafter called AP-107) using crystalline silicotitanate (CST) ion exchange media manufactured by Honeywell UOP, LLC (product IONSIVTM R9140-B, Batch 2081000057) in a lead-lag column system. Since that testing, WRPS has changed the column design to a three-column system. WRPS requested a repeated study with AP-107 tank waste using a different batch of IONSIVTM R9140-B, Lot 2002009604, in a three-column format. A small-scale test platform was constructed to demonstrate solids filtration, Cs removal, and LAW vitrification and installed at Pacific Northwest National Laboratory. This report describes the small-scale ion exchange testing system component of the test platform and the processing of approximately 8.55 L of filtered AP-107 supernate using CST, Lot 8056262-999, that passed through a 25-mesh filter. This report also describes the Cs ion exchange batch contact testing to determine the Cs distribution coefficient and the maximum Cs loading capacity in the AP-107 tank waste matrix. Batch contact testing helps to evaluate CST performance on tank waste supernate and is often used prior to processing tank waste through ion exchange columns to assess some performance metrics (e.g., 50% Cs breakthrough). Batch contact tests were performed with the filtered AP-107 tank waste at four Cs concentrations at a phase ratio of 200 (liquid volume to exchanger mass). The distribution coefficient (K d ) at the equilibrium condition of 9.2 µg Cs/mL (AP-107 feed condition) was determined to be 806 mL AP 107/g CST. With a CST bed density of 1.01 g/mL (<25 mesh CST), this K d corresponded to a predicted 50% Cs breakthrough of 814 bed volumes (BVs). The Cs load capacity at the equilibrium feed condition was determined to be 8.3 mg Cs/g dry CST. The three-column format testing was prototypic to the intended TSCR operations, albeit on a small scale with 10-mL CST beds. Flowrate was adjusted to match the CST contact time expected for the full-scale operation, i.e., matched bed volumes per hour (BV/h) flow rate. The feed was processed downflow through the lead column, then through the middle column, and then through the polish column. Loading continued at an average of 1.88 BV/h (1.83 to 2.04 BV/h range) until the entire available AP-107 feed was processed. The Cs-decontaminated product will be provided for vitrification testing. The lead column only reached 45% Cs breakthrough after processing 855 BVs of feed. The 50% Cs breakthrough was extrapolated to occur at ~900 BVs. This extrapolated 50% Cs breakthrough value differed from the batch contact estimate (814 BVs) by 13%. The waste acceptance criteria (WAC) or contract limit for the WTP LAW vitrification facility is 3.18E-5 Ci 137 Cs per mole Na. For the AP-107 tank waste, only 0.127% of the influent 137 Cs concentration may be delivered to the WTP; this required a Cs decontamination factor of 787. The Cs effluent from the middle column reached the WAC after processing 590 BVs. Cs breakthrough from the polish column began at 590 BVs, reaching 6.3E-3 µCi/mL or 4.3E-3% Cs breakthrough after processing 844 BVs of feed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of Infiltration Test Methods for Soil Health Assessment

Infiltration rate (IR) has been commonly used as a metric to evaluate soil quality and health. For the USDA Soil Quality Test Kit, a 15-cm (6-in) diameter (ID) cylinder is used to measure IR with 444 cm 3 (equivalent to 2.54 cm or 1 in) of water while other standard IR procedures require substantially larger volumes of water. The general objective of this study was to compare different methods for IR measurement. Using three replications, IR measurements were conducted along a 9-m (27-ft) long transect in two different soil types by the double-ring infiltrometer (DRI) using 25- and 50-cm (10-and 20-in, respectively) cylinders, single-ring infiltrometer (SRI) using 25- and 50-cm cylinders, Cornell sprinkle infiltrometer (CSI) using a 24.1-cm (9.5-in) cylinder, the USDA recommended procedure using a 15-cm diameter cylinder (hereafter referred to as USDA-15 method), and a modified USDA method using a 24.1-cm diameter cylinder. Although the USDA-15 method is simple and requires a small amount of water, based on high variability among replications and significant reduction in IR during early stages of water entry into the soil, the procedure does not offer an accurate estimate of the soil infiltration potential. The CSI procedure was reproducible, but it is more cumbersome to perform than other methods. The DRI, SRI, and CSI methods required a much greater volume of water than the USDA-15 method but produced results that are more consistent. The most consistent results were obtained by the CSI and DRI methods. The modified USDA method results were similar to the SRI method and were an improvement over the original USDA-15 method. For assessing soil health, additional investigations should be conducted to evaluate a modified version of the USDA procedure using a larger cylinder.

54 ENVIRONMENTAL SCIENCES↗

A review of regulatory standard test methods for residential wood heaters and recommendations for their advancement

In many regions, residential wood heaters are a leading source of harmful air pollution but only satisfy a small portion of local heating demands. In response, standardized laboratory test methods have been developed to characterize and limit wood heater emissions. While these test methods are a key tool for advancing both wood heater technology and environmental regulations, many of the experimental procedures are outdated and provide few actionable insights for improving heater performance. Furthermore, these test methods vary widely around the world and may not adequately capture the performance of wood heaters operating in residences. This study presents a comprehensive review of standardized wood heater test methods to identify fundamental experimental objectives and regulated performance metrics. Using the results of this review, recommendations are provided to make the test methods more accessible and representative of residential performance, while generating actionable data to motivate heater design improvements. This study elucidates the current state of standard test methods, and the developments needed to advance clean wood heater technologies and public policies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Should regional ventilation function be considered during radiation treatment planning to prevent radiation-induced complications?

Purpose: To investigate the incorporation of pretherapy regional ventilation function in predicting radiation fibrosis (RF) in stage III nonsmall cell lung cancer (NSCLC) patients treated with concurrent thoracic chemoradiotherapy. Methods: Thirty-seven patients with stage III NSCLC were retrospectively studied. Patients received one cycle of cisplatin–gemcitabine, followed by two to three cycles of cisplatin–etoposide concurrently with involved-field thoracic radiotherapy (46–66 Gy; 2 Gy/fraction). Pretherapy regional ventilation images of the lung were derived from 4D computed tomography via a density change–based algorithm with mass correction. In addition to the conventional dose–volume metrics (V{sub 20}, V{sub 30}, V{sub 40}, and mean lung dose), dose–function metrics (fV{sub 20}, fV{sub 30}, fV{sub 40}, and functional mean lung dose) were generated by combining regional ventilation and radiation dose. A new class of metrics was derived and referred to as dose–subvolume metrics (sV{sub 20}, sV{sub 30}, sV{sub 40}, and subvolume mean lung dose); these were defined as the conventional dose–volume metrics computed on the functional lung. Area under the receiver operating characteristic curve (AUC) values and logistic regression analyses were used to evaluate these metrics in predicting hallmark characteristics of RF (lung consolidation, volume loss, and airway dilation). Results: AUC values for the dose–volume metrics in predicting lung consolidation, volume loss, and airway dilation were 0.65–0.69, 0.57–0.70, and 0.69–0.76, respectively. The respective ranges for dose–function metrics were 0.63–0.66, 0.61–0.71, and 0.72–0.80 and for dose–subvolume metrics were 0.50–0.65, 0.65–0.75, and 0.73–0.85. Using an AUC value = 0.70 as cutoff value suggested that at least one of each type of metrics (dose–volume, dose–function, dose–subvolume) was predictive for volume loss and airway dilation, whereas lung consolidation cannot be accurately predicted by any of the metrics. Logistic regression analyses showed that dose–function and dose–subvolume metrics were significant (P values ≤ 0.02) in predicting volume airway dilation. Likelihood ratio test showed that when combining dose–function and/or dose–subvolume metrics with dose–volume metrics, the achieved improvements of prediction accuracy on volume loss and airway dilation were significant (P values ≤ 0.04). Conclusions: The authors’ results demonstrated that the inclusion of regional ventilation function improved accuracy in predicting RF. In particular, dose–subvolume metrics provided a promising method for preventing radiation-induced pulmonary complications.

60 APPLIED LIFE SCIENCES↗

GALAXY-SCALE STRONG-LENSING TESTS OF GRAVITY AND GEOMETRIC COSMOLOGY: CONSTRAINTS AND SYSTEMATIC LIMITATIONS

Galaxy-scale strong gravitational lenses with measured stellar velocity dispersions allow a test of the weak-field metric on kiloparsec scales and a geometric measurement of the cosmological distance-redshift relation, provided that the mass-dynamical structure of the lensing galaxies can be independently constrained to a sufficient degree. We combine data on 53 galaxy-scale strong lenses from the Sloan Lens ACS Survey with a well-motivated fiducial set of lens-galaxy parameters to find (1) a constraint on the post-Newtonian parameter gamma = 1.01 +- 0.05, and (2) a determination of OMEGA{sub L}AMBDA = 0.75 +- 0.17 under the assumption of a flat universe. These constraints assume that the underlying observations and priors are free of systematic error. We evaluate the sensitivity of these results to systematic uncertainties in (1) total mass-profile shape, (2) velocity anisotropy, (3) light-profile shape, and (4) stellar velocity dispersion. Based on these sensitivities, we conclude that while such strong-lens samples can, in principle, provide an important tool for testing general relativity and cosmology, they are unlikely to yield precision measurements of gamma and OMEGA{sub L}AMBDA unless the properties of the lensing galaxies are independently constrained with substantially greater accuracy than at present.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of Dual Pressurized Rover Operations During Simulated Planetary Surface Exploration

Introduction: A pair of small pressurized rovers (Space Exploration Vehicles, or SEVs) is at the center of the Global Point-of-Departure architecture for future human planetary exploration. Simultaneous operation of multiple crewed surface assets should maximize productive crew time, minimize overhead, and preserve contingency return paths. Methods: A 14-day mission simulation was conducted in the Arizona desert as part of NASA?s 2010 Desert Research and Technology Studies (DRATS). The simulation involved two SEV concept vehicles performing geological exploration under varied operational modes affecting both the extent to which the SEVs must maintain real-time communications with mission control ("Continuous" vs. "Twice-a-Day") and their proximity to each other ("Lead-and-Follow" vs. "Divide-and-Conquer"). As part of a minimalist lunar architecture, no communications relay satellites were assumed. Two-person crews consisting of an astronaut and a field geologist operated each SEV, day and night, throughout the entire 14-day mission, only leaving via the suit ports to perform simulated extravehicular activities. Standard metrics enabled quantification of the habitability and usability of all aspects of the SEV concept vehicles throughout the mission, as well as comparison of the extent to which the operating modes affected crew productivity and performance. Practically significant differences in the relevant metrics were prospectively defined for the testing of all hypotheses. Results and Discussion: Data showed a significant 14% increase in available science time (AST) during Lead-and-Follow mode compared with Divide-and-Conquer, primarily because of the minimal overhead required to maintain communications during Lead-and-Follow. In Lead-and-Follow mode, there was a non-significant 2% increase in AST during Twice-a-Day vs. Continuous communications. Situational awareness of the other vehicle?s location, activities, and contingency return constraints were enhanced during Lead-and-Follow and Twice-a-Day communications modes due to line-of-sight and direct SEV-to-SEV communication. Preliminary analysis of Scientific Data Quality and Observation Quality metrics showed no significant differences between modes.

Abercromby, Andrew F. J.↗

Comparing the Electrical Modeling and Thermal Analysis Toolbox Simulation Data to Electrified Aircraft Propulsion Test Hardware Data

A model using the Electrical Modeling and Thermal Analysis Toolbox (EMTAT), a National Aeronautics and Space Administration (NASA)-developed Simulink® model block library of electrical components, was developed to mirror the Hybrid Propulsion Emulation Rig (HyPER) hardware, a laboratory focused on Electrified Aircraft Propulsion (EAP) hardware tests. The goal of the model was to demonstrate the utility of the library by comparing the accuracy of the library models to the performance of real hardware, with the primary metrics being the simulation outputs matching physical test hardware data within 5% of full scale.The objective of this paper is to present the background, setup, testing and results of this comparison. It describes some of the adjustments that were necessary to match the system hardware, as well as next steps in verification and validation. The outputs of the model were compared to the results of several tests in HyPER, and in the process captured an additional torque loss that is still being analyzed for the root cause but has been confirmed in the hardware. Across all the test series, only one key model parameter was outside the target 5% full scale matching, and nearly 70% were within 1%.

Mark E Bell↗

Comparing the Electrical Modeling and Thermal Analysis Toolbox Simulation Data to Electrified Aircraft Propulsion Test Hardware Data

A model using the Electrical Modeling and Thermal Analysis Toolbox (EMTAT), a National Aeronautics and Space Administration (NASA)-developed Simulink® model block library of electrical components, was developed to mirror the Hybrid Propulsion Emulation Rig (HyPER) hardware, a laboratory focused on Electrified Aircraft Propulsion (EAP) hardware tests. The goal of the model was to demonstrate the utility of the library by comparing the accuracy of the library models to the performance of real hardware, with the primary metrics being the simulation outputs matching physical test hardware data within 5 percent of full scale. The objective of this paper is to present the background, setup, testing and results of this comparison. It describes some of the adjustments that were necessary to match the system hardware, as well as next steps in verification and validation. The outputs of the model were compared to the results of several tests in HyPER, and in the process captured an additional torque loss that is still being analyzed for the root cause but has been confirmed in the hardware. Across all the test series, only one key model parameter was outside the target 5 percent full scale matching, and nearly 70 percent were within 1 percent.

Mark E. Bell↗

Comparison Between THOR Anthropomorphic Test Device and THOR Finite Element Model

Extended time spent in reduced gravity can cause physiologic deconditioning of astronauts, reducing their ability to sustain excessive forces during dynamic phases of spaceflight such as landing. To make certain that the crew is safe during these phases, NASA must take caution when determining what types of landings are acceptable based on the accelerations applied to the astronaut. In order to test acceptable landings, various trials have been run accelerating humans, cadavers, and Anthropomorphic Test Devices (ATDs), or crash test dummies, at different acceleration and velocity rates on a sled testing platform. Using these tests, risks of injury will be created and metrics will be developed for the likelihood of injuries due to the acceleration. A finite element model (FEM) of the Test Device for Human Occupant Restraint (THOR) ATD has been developed that can simulate these test trials and others (Putnam, 2014), reducing the need for human and ATD testing. Additionally, this will give researchers a more effective way to test the accelerations and orientations encountered during spaceflight landings during design of new space vehicles for crewed missions. However, the FEM has not been proven and must be validated by comparing the forces, accelerations, and other measurements of all parts of the body between the physical tests already completed and computer simulated trials. The purpose of my research was to validate the FEM for the ATD using previously run trials with the physical THOR ATD.

Moore, Erik↗

System Effectiveness

An effective risk assessment system is needed to address the threat posed by an active or passive insider who, acting alone or in collusion, could attempt diversion or theft of nuclear material. It is critical that a nuclear facility conduct a thorough self-assessment of the material protection, control, and accountability (MPC&A) system to evaluate system effectiveness. Self-assessment involves vulnerability analysis and performance testing of the MPC&A system. The process should lead to confirmation that mitigating features of the system effectively minimize the threat, or it could lead to the conclusion that system improvements or upgrades are necessary to achieve acceptable protection against the threat. Analysis of the MPC&A system is necessary to understand the limits and vulnerabilities of the system to internal threats. Self-assessment helps the facility be prepared to respond to internal threats and reduce the risk of theft or diversion of nuclear material. MSET is a self-assessment or inspection tool utilizing probabilistic risk assessment (PRA) methodology to calculate the system effectiveness of a nuclear facility's MPC&A system. MSET analyzes the effectiveness of an MPC&A system based on defined performance metrics for MPC&A functions based on U.S. and international best practices and regulations. A facility's MC&A system can be evaluated at a point in time and reevaluated after upgrades are implemented or after other system changes occur. The total system or specific subareas within the system can be evaluated. Areas of potential performance improvement or system upgrade can be assessed to determine where the most beneficial and cost-effective improvements should be made. Analyses of risk importance factors show that sustainability is essential for optimal performance. The analyses reveal where performance degradation has the greatest detrimental impact on total system risk and where performance improvements have the greatest reduction in system risk. The risk importance factors show the amount of risk reduction achievable with potential upgrades and the amount of risk reduction actually achieved after upgrades are completed. Applying the risk assessment tool gives support to budget prioritization by showing where budget support levels must be sustained for MC&A functions most important to risk. Results of the risk assessment are also useful in supporting funding justifications for system improvements that significantly reduce system risk.

99 GENERAL AND MISCELLANEOUS↗

The 2010 Desert Rats Science Operations Test: Outcomes and Lessons Learned

The Desert RATS 2010 Team tested a variety of science operations management techniques, applying experience gained during the manned Apollo missions and the robotic Mars missions. This test assessed integrated science operations management of human planetary exploration using real-time, tactical science operations to oversee daily crew science activities, and a night shift strategic science operations team to conduct strategic level assessment of science data and daily traverse results. In addition, an attempt was made to collect numerical metric data on the outcome of the science operations to assist test evaluation. The two most important outcomes were 1) the production of significant (almost overwhelming) volume of data produced during daily traverse operations with two rovers, advanced imaging systems and well trained, scientifically proficient crew-members, and 2) the degree to which the tactical team s interaction with the surface crew enhanced science return. This interaction depended on continuous real-time voice and data communications, and the quality of science return from any human planetary exploration mission will be based strongly on the aggregate interaction between a well trained surface crew and a dedicated science operations support team using voice and imaging data from a planet s surface. In addition, the scientific insight developed by both the science operations team and the crews could not be measurable by simple numerical quantities, and its value will be missed by a purely metric-based evaluation of test outcome. In particular, failure to recognize the critical importance of this qualitative type interaction may result in mission architecture choices that will reduce science return.

Eppler, D. B.↗

A Change Impact Analysis to Characterize Evolving Program Behaviors

Change impact analysis techniques estimate the potential effects of changes made to software. Directed Incremental Symbolic Execution (DiSE) is an intraprocedural technique for characterizing the impact of software changes on program behaviors. DiSE first estimates the impact of the changes on the source code using program slicing techniques, and then uses the impact sets to guide symbolic execution to generate path conditions that characterize impacted program behaviors. DiSE, however, cannot reason about the flow of impact between methods and will fail to generate path conditions for certain impacted program behaviors. In this work, we present iDiSE, an extension to DiSE that performs an interprocedural analysis. iDiSE combines static and dynamic calling context information to efficiently generate impacted program behaviors across calling contexts. Information about impacted program behaviors is useful for testing, verification, and debugging of evolving programs. We present a case-study of our implementation of the iDiSE algorithm to demonstrate its efficiency at computing impacted program behaviors. Traditional notions of coverage are insufficient for characterizing the testing efforts used to validate evolving program behaviors because they do not take into account the impact of changes to the code. In this work we present novel definitions of impacted coverage metrics that are useful for evaluating the testing effort required to test evolving programs. We then describe how the notions of impacted coverage can be used to configure techniques such as DiSE and iDiSE in order to support regression testing related tasks. We also discuss how DiSE and iDiSE can be configured for debugging finding the root cause of errors introduced by changes made to the code. In our empirical evaluation we demonstrate that the configurations of DiSE and iDiSE can be used to support various software maintenance tasks

Rungta, Neha Shyam↗

Regression Model Term Selection for the Analysis of Strain-Gage Balance Calibration Data

The paper discusses the selection of regression model terms for the analysis of wind tunnel strain-gage balance calibration data. Different function class combinations are presented that may be used to analyze calibration data using either a non-iterative or an iterative method. The role of the intercept term in a regression model of calibration data is reviewed. In addition, useful algorithms and metrics originating from linear algebra and statistics are recommended that will help an analyst (i) to identify and avoid both linear and near-linear dependencies between regression model terms and (ii) to make sure that the selected regression model of the calibration data uses only statistically significant terms. Three different tests are suggested that may be used to objectively assess the predictive capability of the final regression model of the calibration data. These tests use both the original data points and regression model independent confirmation points. Finally, data from a simplified manual calibration of the Ames MK40 balance is used to illustrate the application of some of the metrics and tests to a realistic calibration data set.

Ulbrich, Norbert Manfred↗

Spatial and temporal variation in river corridor exchange across a 5th-order mountain stream network

Although most field and modeling studies of river corridor exchange have been conducted at scales ranging from tens to hundreds of meters, results of these studies are used to predict their ecological and hydrological influences at the scale of river networks. Further complicating prediction, exchanges are expected to vary with hydrologic forcing and the local geomorphic setting. While we desire predictive power, we lack a complete spatiotemporal relationship relating discharge to the variation in geologic setting and hydrologic forcing that is expected across a river basin. Indeed, the conceptual model of Wondzell (2011) predicts systematic variation in river corridor exchange as a function of (1) variation in baseflow over time at a fixed location, (2) variation in discharge with location in the river network, and (3) local geomorphic setting. To test this conceptual model we conducted more than 60 solute tracer studies including a synoptic campaign in the 5th-order river network of the H. J. Andrews Experimental Forest (Oregon, USA) and replicate-in-time experiments in four watersheds. We interpret the data using a series of metrics describing river corridor exchange and solute transport, testing for consistent direction and magnitude of relationships relating these metrics to discharge and local geomorphic setting. We confirmed systematic decrease in river corridor exchange space through the river networks, from headwaters to the larger main stem. However, we did not find systematic variation with changes in discharge through time or with local geomorphic setting. While interpretation of our results is complicated by problems with the analytical methods, the results are sufficiently robust for us to conclude that space-for-time and time-for-space substitutions are not appropriate in our study system. Finally, we suggest two strategies that will improve the interpretability of tracer test results and help the hyporheic community develop robust datasets that will enable comparisons across multiple sites and/or discharge conditions.

54 ENVIRONMENTAL SCIENCES↗