Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transient simulations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Novel Approach to PV Inverter Modeling and Simulation Leveraging Experiments, Learning Based Modeling and Co-Simulation

Photovoltaic (PV) inverter manufacturers use custom, proprietary control approaches and topologies in their inverter design. The proprietary nature of these approaches makes it challenging to share electromagnetic transients (EMT) domain models for system studies. This research work presents an approach to develop EMT models from experimental data. We use novel approach in experimental design, high fidelity data collection, use of learning-based modeling, and co-simulation to reduce the time taken to develop an EMT model for an inverter under test (IUT). We used a 20 kW off-the-shelf grid following PV inverter and subjected the inverter to controlled tests. The tests include voltage and frequency step changes, as well as solar irradiance variations. The recorded high frequency data were used to train a neural network model representing the dynamic behavior of the IUT. The model was subsequently imported into an EMT tool using co-simulation techniques, and thus completing the modeling effort.

black box inverter modeling↗

Demonstrating the Transient System Impact of Cyber-Physical Events Through Scalable Transmission and Distribution (T&D) Co-Simulation

Modern power systems become more vulnerable to cyber threats due to their growing interconnectivity, interdependence, and complexity. Widespread deployment of distributed energy resources (DERs) further expands the threat landscape to the grid edge, where fewer cybersecurity protections exist. In this article, a systematic cyber-physical events demonstration, enabled by an integrated transmission, distribution, and communication co-simulation framework, is performed. It analyzes cyber risks to power grid under DER-enabled automatic generation control from different angles. Unlike existing works, the simulation captures millisecond-to-minutes frequency and voltage transient dynamics at a cross-region system scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inferring Neutron Star Merger Ejecta Morphology with Kilonovae

In this study we incorporate a new grid of kilonova simulations produced by the Monte Carlo radiative transfer code SuperNu in an inference pipeline for astrophysical transients and evaluate their performance. These simulations contain four different two-component ejecta morphology classes. We analyze follow-up observational strategies by Vera Rubin Observatory in optical and James Webb Space Telescope (JWST) in mid-infrared (MIR). Our analysis suggests that, within these strategies, it is possible to discriminate between the four different morphologies only when late-time JWST observations in MIR are available. We conclude that follow-ups by the new Vera Rubin Observatory alone are not sufficient to determine ejecta morphology. Additionally, we make comparisons between surrogate models based on radiative transfer simulation grids by SuperNu and POSSIS, by analyzing the historic kilonova AT2017gfo that accompanied the gravitational wave event GW170817. We show that both SuperNu and POSSIS models provide similar fits to photometric observations but their qualitative interpretations differ.

79 ASTRONOMY AND ASTROPHYSICS↗

Candidate strongly lensed type Ia supernovae in the Zwicky Transient Facility archive

Gravitationally lensed type Ia supernovae (glSNe Ia) are unique astronomical tools that can be used to study cosmological parameters, distributions of dark matter, the astrophysics of the supernovae, and the intervening lensing galaxies themselves. A small number of highly magnified glSNe Ia have been discovered by ground-based telescopes such as the Zwicky Transient Facility (ZTF), but simulations predict that a fainter, undetected population may also exist. We present a systematic search for glSNe Ia in the ZTF archive of alerts distributed from June 1 2019 to September 1 2022. Using the AMPEL platform, we developed a pipeline that distinguishes candidate glSNe Ia from other variable sources. Initial cuts were applied to the ZTF alert photometry (with constraints on the peak absolute magnitude and the distance to a catalogue-matched galaxy, as examples) before forced photometry was obtained for the remaining candidates. Additional cuts were applied to refine the candidates based on their light curve colours, lens galaxy colours, and the resulting parameters from fits to the SALT2 SN Ia template. The candidates were also cross-matched with the DESI spectroscopic catalogue. Seven transients were identified that passed all the cuts and had an associated galaxy DESI redshift, which we present as glSN Ia candidates. Although superluminous supernovae (SLSNe) cannot be fully rejected as contaminants, two events, ZTF19abpjicm and ZTF22aahmovu, are significantly different from typical SLSNe and their light curves can be modelled as two-image glSN Ia systems. From this two-image modelling, we estimate time delays of 22 ± 3 and 34 ± 1 days for the two events, respectively, which suggests that we have uncovered a population of glSNe Ia with longer time delays. The pipeline is efficient and sensitive enough to parse full alert streams. It is currently being applied to the live ZTF alert stream to identify and follow-up future candidates while active. This pipeline could be the foundation for glSNe Ia searches in future surveys, such as the Rubin Observatory Legacy Survey of Space and Time.

79 ASTRONOMY AND ASTROPHYSICS↗

Enabling topography-resolving structural dynamic contact simulation

Damping of structures and systems is often dominated by frictional dissipation in connections, the prediction of which remains a longstanding scientific challenge. Previous studies have shown that the actual topography of contact interfaces may have a strong effect, especially in the partial slip/liftoff regime. We recently proposed a multi-scale method, which couples finite element and boundary element modeling. The primary benefit of this approach is that it permits to analyze the effect of the actual contact topography on the dynamics of jointed structures. While this multi-scale modeling method was initially developed for quasi-static analysis, we demonstrate herein how it can be used for time step integration and Harmonic Balance analysis. We cross-verify those fully dynamic analysis methods against each other and quasi-static results, for the S4 Beam benchmark. We compare the multi-scale method against state-of-the-art full-FE analysis, in terms of numerical damping and computational performance. Some discrepancy is found to be of physical origin. Depending on the load history, it is shown that the system settles to a slightly different equilibrium. Finally, transient multi-scale simulations enable the prediction of this interesting phenomenon, for the first time, for a structure with bolted joints.

Frictional-unilateral contact↗

Understanding Line Losses and Transformer Losses in Rural Isolated Distribution Systems

Rural, isolated power systems in the mainland U.S. and in states like Alaska and Hawaii are powered by assets like diesel generators. These rural, isolated power systems also cannot operate at the higher band of medium voltage (like 69kV). They are primarily in the 12 to 14 kV range to keep the cost of the distribution investments lower. Because of this mid-band medium voltage range, the line losses and distribution transformers losses consume significant diesel consumption (almost 10 percent of the peak load). This work considers one such power system powering an isolated system and presents key findings online losses, and transformer losses. Understanding and documenting the impacts is critical for these communities operating their power systems and take actions to reduce expensive diesel consumption. In this paper, we will present one such typical grid and model it in electromagnetic transients (EMT) domain. We used the tower structure, under ground cabling installation to develop high fidelity models of lines. We also used high fidelity models of distribution transformers to present the no-load losses and full load loses. We will also present technical solutions available commercially off-the-shelf to reduce these losses and reduce diesel consumption. This work will be a primer for communities to understand the technical challenges and to understand the possible solution available to solve such challenges for rural, isolated power system operators.

blackstart↗

Model based co-simulation platform for integrated building system control and design optimization

Both steady-state and dynamic simulations have been widely used by HVAC&R industry to support product/equipment development for decades. Steady-state simulation focuses on the system mass, energy and momentum balance of an equilibrium state. It is based on high-fidelity components models, and thus is suitable for system and component design optimization. Dynamic simulation studies the system transient response and is generally used for controls development and verification. It usually does not require rigorous component models of high accuracy because 1) the commonly used PID control is feedback control whose control performance evaluation doesn’t require high fidelity system/plant model; 2) high-fidelity dynamic model significantly increases the number of equations and variables and creates tremendous challenge for math solver. For supervisory control, transactive control or optimization of an integrated building system, the HVAC&R equipment is often one of the sub-components to be controlled. High-fidelity equipment models are required for accurately evaluating control strategies. In addition, building equipment manufacturers have developed a lot of high-fidelity steady-state equipment/component models per their expertise. Thus, a platform that can integrate OEM high-fidelity steady-state model with dynamic building simulation and/or electric power system & grid simulation to support the development and verification of supervisory control for integrated building systems is necessary. In this study, ORNL’s heat pump design tool (HPDM) is utilized to develop a co-simulation platform for supervisory control and optimization in integrated building systems. It is based on a model that integrates high-fidelity steady-state simulation equipment models with dynamic building simulation. A practical case of using the proposed co-simulation platform to develop and evaluate the supervisory control and optimization is presented and discussed.

Sun, Jian↗

Control System of Multi-Port Autonomous Reconfigurable Solar Power Plant (MARS) & HIL Platforms for Design

Multi-port autonomous reconfigurable solar power plant (MARS) provides an attractive alternative to connect photovoltaic (PV) and energy storage systems (ESSs) to high-voltage direct current (HVdc) links and high-voltage alternating current (ac) grids. In this paper, a unique hierarchical control system of MARS is proposed and evaluated. To evaluate the control system and associated algorithms in early-stage research of complex architectures like MARS, it is important to develop unique suitable hardware-in-the-loop (HIL) platforms. In this paper, the HIL platforms for MARS to evaluate the performance of the hierarchical control system and the control algorithms implemented are presented. Further, they help with the design process of control systems. The real-time simulation models and algorithms that are utilized for MARS in the HIL platforms are also discussed in the paper. The HIL experiments of the control system of MARS showcase the capability to provide continuity of operation under faults and frequency support to the power grid during loss of generation. They also showcase the stability of the proposed hierarchical control system of MARS.

14 SOLAR ENERGY↗

Anisotropic X-Ray Scattering of Transiently Oriented Water

We study the structural dynamics of liquid water by time-resolved anisotropic x-ray scattering under the optical Kerr effect condition. In this way, we can separate the anisotropic scattering decay of 160 fs from the delayed temperature increase of ~ 0.1 K occurring at 1 ps and quantify transient changes in the O-O pair distribution function. Polarizable molecular dynamics simulations reproduce well the experiment, indicating transient alignment of molecules along the electric field, which shortens the nearest-neighbor distances. In addition, analysis of the simulated water local structure provides evidence that two hypothesized fluctuating water configurations exhibit different polarizability.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Understanding Line Losses and Transformer Losses in Rural Isolated Distribution Systems: Preprint

Rural, isolated power systems in the mainland U.S. and in states like Alaska and Hawaii are powered by assets like diesel generators. These rural, isolated power systems also cannot operate at the higher band of medium voltage (like 69kV). They are primarily in the 12 to 14 kV range to keep the cost of the distribution investments lower. Because of this mid-band medium voltage range, the line losses and distribution transformers losses consume significant diesel consumption (almost 10 percent of the peak load). This work considers one such power system powering an isolated system and presents key findings online losses, and transformer losses. Understanding and documenting the impacts is critical for these communities operating their power systems and take actions to reduce expensive diesel consumption. In this paper, we will present one such typical grid and model it in electromagnetic transients (EMT) domain. We used the tower structure, under ground cabling installation to develop high fidelity models of lines. We also used high fidelity models of distribution transformers to present the no-load losses and full load loses. We will also present technical solutions available commercially off-the-shelf to reduce these losses and reduce diesel consumption. This work will be a primer for communities to understand the technical challenges and to understand the possible solution available to solve such challenges for rural, isolated power system operators.

blackstart↗

Unfolding bovine α-lactalbumin with T-jump: Characterizing disordered intermediates via time-resolved x-ray solution scattering and molecular dynamics simulations

The protein folding process often proceeds through partially folded transient states. Therefore, a structural understanding of these disordered states is crucial for developing mechanistic models of the folding process. Characterization of unfolded states remains challenging due to their disordered nature, and incorporating multiple methods is necessary. Combining the time-resolved x-ray solution scattering (TRXSS) signal with molecular dynamics (MD), we are able to characterize transient partially folded states of bovine α-lactalbumin, a model system widely used for investigation of molten globule states, during its unfolding triggered by a temperature jump. We track the unfolding process between 20 μs and 70 ms and demonstrate that it passes through three distinct kinetic states. The scattering signals associated with these transient species are then analyzed with TRXSS constrained MD simulations to produce protein structures that are compatible with the input signals. Without utilizing any experimentally extracted kinetic information, the constrained MD simulation successfully drove the protein to an intermediate molten globule state; signals for two later disordered states are refined to terminal unfolded states. From our examination of the structural characteristics of these disordered states, we discuss the implications disordered states have on the folding process, especially on the folding pathway. Finally, we discuss the potential applications and limitations of this method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated Optimization and Control of a Hybrid Gas Turbine/sCO 2 Power System

During phase-I, the project team led by Echogen Power Systems (EPS) had two primary objectives based on investigating the application of gas turbines with supercritical carbon dioxide (sCO 2 ) power cycles. The first objective was to improve the overall efficiency and performance of a hybrid gas turbine/sCO 2 power system through a joint optimization of the two subsystems (gas turbine and sCO 2 power cycle) using non-linear optimization techniques that simultaneously evaluate thermal performance of the combined cycle. The hybrid power system included several points of interaction, including (but not limited to) gas turbine exhaust, fuel heating, inlet chilling and turbine cooling. The second objective was to establish a baseline transient response model of the hybrid power system and a notional microgrid and begin steps to integrate the control systems of the three major elements (gas turbine, sCO 2 cycle and grid controller). The project team established a baseline performance for a combined cycle power plant using a production gas turbine and scaled sCO 2 power cycle only utilizing exhaust heat recovery. Echogen’s non-linear techno-economic optimization code was extended by adding gas turbine component models derived from a in-house developed gas turbine design code. With the two cycles coupled by the gas turbine exhaust, design parameters of both cycles were allowed to vary simultaneously to determine performance opportunity versus isolated designs. Returning to the baseline gas turbine/sCO 2 power cycle transient models: Echogen had in-house developed sCO 2 cycle transient model in GT-Suite system simulation software, and had partnered with Siemens Finspång for gas turbine transient model, and Siemens PTI group to provide micro-grid load profile as well as hybrid power cycle generated load (power and frequency) analysis. The transient model for the SGT-750 Siemens gas turbine was a “black-box” functional mock-up interface (FMI) model developed by Siemens Industrial Turbomachinery in Finspång, Sweden. The SGT-750 is a twin-shaft gas turbine that produces 40 MW electricity with an efficiency of about 40% at ISO conditions. At 100% gas turbine throttle (load), the SGT-750 has average exhaust conditions of 114.6 kg/s and 469.8°C. The transient model for sCO 2 power cycle was developed by Echogen in GT-SUITE 1D system simulation software platform. The basic CO 2 flow circuit has single-shaft turbomachinery with net 11.5 MW electrical power output at design conditions. The power turbine has a double-ended shaft with one end connected to synchronous generator through a fixed-ratio gearbox. The other end of power turbine is connected to the compressor through a continuously variable transmission. The major components of the sCO 2 power cycle modeled include air cooled condenser/cooler, CO 2 compressor, recuperator, two waste heat exchanger coils, power turbine, continuous variable transmission, gearbox and generator. Integration of SGT-750 transient model and sCO 2 power cycle transient model was done in Matlab Simulink. In the integrated model, the gas turbine and sCO 2 power cycle interacted at two points, first one being the gas turbine exhaust gas flow rate and temperature, which were inputs to sCO 2 power cycle model. The second point was the distribution of micro-grid load demand signal between the SGT-750 generator and sCO 2 cycle generator. For a given combined-cycle load demand, the gas turbine load demand was equal to the total demand minus the sCO 2 cycle power generated. In the present study the integrated model was simulated for two cases of grid load demand: (i) for a step change, both positive-step and negative-step, in grid load demand (ii) for a micro-grid load demand curve provided by Siemens PTI group. Finally, the time series plots representing load demand versus integrated system response were presented including the sCO 2 power cycle control system performance plots. The actual generated power and frequency of both the generators, gas turbine and sCO 2 power cycle, was supplied to Siemens PTI group for dynamic grid assessment, results of which are provided in appendices.

03 NATURAL GAS↗

The value of in-reservoir energy storage for flexible dispatch of geothermal power

Geothermal systems making use of advanced drilling and well stimulation techniques have the potential to provide tens to hundreds of gigawatts of clean electricity generation in the United States by 2050. With near-zero variable costs, geothermal plants have traditionally been envisioned as providing “baseload” power, generating at their maximum rated output at all times. However, as variable renewable energy sources (VREs) see greater deployment in energy markets, baseload power is becoming increasingly less competitive relative to flexible, dispatchable generation and energy storage. Herein we conduct an analysis of the potential for future geothermal plants to provide both of these services, taking advantage of the natural properties of confined, engineered geothermal reservoirs to store energy in the form of accumulated, pressurized geofluid and provide flexible load-following generation. We develop a linear optimization model based on multi-physics reservoir simulations that captures the transient pressure and flow behaviors within a confined, engineered geothermal reservoir. We then optimize the investment decisions and hourly operations of a power plant exploiting such a reservoir against a set of historical and modeled future electricity price series. Further, we find that operational flexibility and in-reservoir energy storage can significantly enhance the value of geothermal plants in markets with high VRE penetration, with energy value improvements of up to 60% relative to conventional baseload plants operating under identical conditions. Across a range of realistic subsurface and operational conditions, our modeling demonstrates that confined, engineered geothermal reservoirs can provide large and effectively free energy storage capacity, with round-trip storage efficiencies comparable to those of leading grid-scale energy storage technologies. Optimized operational strategies indicate that flexible geothermal plants can provide both short- and long-duration energy storage, prioritizing output during periods of high electricity prices. Sensitivity analysis assesses the variation in outcomes across a range of subsurface conditions and cost scenarios.

15 GEOTHERMAL ENERGY↗

The liquid-conduction, vapor-flow heat pipe model in Sockeye

A single-phase heat pipe flow model implemented in the heat pipe application Sockeye is described. This model solves one-dimensional, compressible flow equations for the vapor phase in the center of a heat pipe, which are coupled to the two-dimensional heat conduction equation for the wick, liquid, and cladding, as well as to an ordinary differential equation tracking the working fluid inventory in the evaporator section of the heat pipe. This model is demonstrated with several test problems, including comparisons to analytic solutions for the vapor flow fields, analytic curves for sonic and capillary limitations of heat pipe operation, and some experimental data. The numerical solution gives excellent agreement for verification problems and good agreement with experimental results. Also, demonstrations show that the model is very robust, allowing for full simulations of heat pipe transients, including frozen startup, sonic-limited (supersonic) flow, and heat pipe shutdown.

42 ENGINEERING↗

Local summer insolation and greenhouse gas forcing drove warming and glacier retreat in New Zealand during the Holocene

Geological climate archives from the Holocene Epoch provide baseline information concerning natural climate variability. Temperate mountain glacier extent is sensitive to summer air temperature, thus geological records of past glacier length changes are a useful proxy for this climatic variable. Here we present a new cosmogenic 10 Be chronology of glacier length changes at Dart Glacier in the Southern Alps, New Zealand. Prominent moraines deposited 321 ± 44 yr ago (n = 11) and 7.8 ± 0.3 ka (n = 5) show glaciers during the Little Ice Age were less extensive than during the early Holocene. This pattern of net Holocene glacier retreat is consistent with emerging data from other catchments in New Zealand and across the southern mid-latitudes. Using the physical framework of a transient global climate model simulation, we suggest that cool summers in the early Holocene were promoted by the local summer insolation minimum, together with low atmospheric greenhouse gas concentrations, causing an early Holocene austral glacial maximum. An insolation-driven reduction in seasonality at southern mid-latitudes may reconcile differences between early Holocene temperature reconstructions where climate proxies have different seasonal sensitivities. Furthermore, we suggest that rising greenhouse gas concentrations after 7 ka caused regional-scale glacier retreat and appear to be the dominant driver of multi-millennial summer temperature trends in the southern mid-latitudes during the present interglacial.

58 GEOSCIENCES↗

Mechanisms of Dynamic Near-Wake Modulation of a Utility-Scale Wind Turbine

The current study uses large eddy simulations to investigate the transient response of a utility-scale wind turbine wake to dynamic changes in atmospheric and operational conditions, as observed in previous field-scale measurements. Most wind turbine wake investigations assume quasi-steady conditions, but real wind turbines operate in a highly stochastic atmosphere, and their operation (e.g. blade pitch, yaw angle) changes constantly in response. Furthermore, dynamic control strategies have been recently proposed to optimize wind farm power generation and longevity. Therefore, improved understanding of dynamic wake behaviours is essential. First, changes in blade pitch are investigated and the wake expansion response is found to display hysteresis as a result of flow inertia. The time scales of the wake response to different pitch rates are quantified. Next, changes in wind direction with different time scales are explored. Under short time scales, the wake deflection is in the opposite direction of that observed under quasi-steady conditions. Finally, yaw changes are implemented at different rates, and the maximum inverse wake deflection and time scale are quantified, showing a clear dependence on yaw rate. To gain further physical understanding of the mechanism behind the inverse wake deflection, the streamwise vorticity in different parts of the wake is quantified. The results of this study provide guidance for the design of advanced wake flow control algorithms. The lag in wake response observed for both blade pitch and yaw changes shows that proposed dynamic control strategies must implement turbine operational changes with a time scale of the order of the rotor time scale or slower.

flow-structure interactions↗

Time Scale Dependence of the Meridional Coherence of the Atlantic Meridional Overturning Circulation

The Atlantic Meridional Overturning Circulation (AMOC) variability is suggested to be incoherent between the subpolar and subtropical gyres in the Atlantic on interannual and even decadal time scales, questioning the representativeness of AMOC variability at a single latitude in modern observation and paleoreconstruction. Paleoreconstructions of the Florida Current transport suggest that Florida Current variability is associated with the AMOC on the millennial time scale, but the Rapid Climate Change (RAPID) mooring array suggests a weak correlation between the Florida Current and the AMOC. In this study, we investigate the meridional coherence of AMOC variability and the relationship between the Florida Current variability and the AMOC variability on different time scales in a transient 20,000-year simulation. We find that with the increase of time scales, the meridional coherence of the AMOC increases. On decadal and longer time scales, the coherent subtropical and subpolar AMOC is caused by the coherent buoyancy forcing in the subpolar gyre. Also, the Florida Current transport is highly correlated with AMOC variability on decadal and longer time scales, suggesting that observations of the Florida Current can be used to indicate AMOC variability on long time scales.

54 ENVIRONMENTAL SCIENCES↗

Coupled Multiphysics Simulations of Heat Pipe Microreactors Using DireWolf

DireWolf is a multiphysics software driver application designed to simulate heat pipe–cooled nuclear microreactors. Developed under the U.S. Department of Energy, Office of Nuclear Energy Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, the DireWolf software application’s objective is to provide the nuclear community with a design and safety analysis simulation capability. Based upon the NEAMS program Multiphysics Object-Oriented Simulation Environment (MOOSE) computational framework, DireWolf tightly couples nuclear microreactor physics, reactor physics, radiation transport, nuclear fuel performance, heat pipe thermal hydraulics, power generation, and structural mechanics to resolve the interdependent nonlinearities. DireWolf is capable of simulating both steady and transient normal reactor operation and several postulated failure scenarios. We will present the fundamental physics of heat pipe–cooled nuclear microreactors and the MOOSE-based software employed in DireWolf. Both steady and transient results for coupled reactor physics, radiation transport, and nuclear fuel performance are demonstrated.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗