Search NASA⌕ Search

SEARCH · Search NASA

Results for “User Behavior”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

407 records · Page 23

Deep Learning for Automated Identification of Eels in Sonar Data

Freshwater eels, such as the American eel (Anguilla rostrata) present numerous challenges related to safe downstream fish passage at hydroelectric facilities. One of those challenges is effective monitoring of their abundance, movements, and behavior to facilitate design and operation of eel protection and passage facilities. A previous EPRI study documented the ability of human analysts to reliably identify American eels in data obtained with a 1100/1800 kHz, multibeam sonar. This report describes a project to develop deep learning (a subset of artificial intelligence) tools to automate the time-consuming, subjective process of eel identification in multibeam sonar data. The project exploited new data collected in the laboratory and the existing data from the prior EPRI field study to develop and test deep learning and other data analytic tools, including wavelet filtering, differencing for static object removal, and convolutional neural network analysis. The analysis of the laboratory data demonstrated feasibility of the approach, revealed object characteristics observed with the sonar that distinguish eels from similarly sized and shaped acoustic targets, and provided additional data for algorithm selection and training. Deep learning algorithms trained and tested on the laboratory data alone achieved accuracy rates of greater than 98% when classifying acoustic images of eels and similar-sized neutrally buoyant sticks. The algorithm trained and tested on the pre-existing field data alone, and yielded classification accuracy of 9.3% false positives and 13.3% false negatives when distinguishing between eels and sticks/PVC pipes based on video clips (i.e., multiple, consecutive images). This performance is comparable to the classification accuracy achieved by human analysts in the prior study. The deep learning algorithm trained on a combination of video clips obtained in the laboratory and the field and tested on video clips from the field, was able to distinguish eels from sticks and PVC pipes (a river debris analog) of similar size with 100% accuracy. Outreach to the hardware, software, and end-user communities early in the project helped to identify needs and specify the application space. Outreach to those communities at the end of the project communicated project results and opportunities for further development. The project achieved proof of concept for automated identification of eel in multibeam sonar data. Future work should focus on acquisition of additional data for more robust algorithm training and testing; modification of the software tools to accommodate multiple acoustic targets in the acoustic field at a given time; identification of additional object classes; incorporation of motion in the object identification and classification algorithms; operationalizing the software tools, including integration with other existing sonar data analysis tools; and partnering with hardware and software providers for distribution of the software tools with their commercial products.

13 HYDRO ENERGY↗

SAM Code Enhancements for Fission Product Tracking of Noble Gases and Metals in MSRs

This report documents fiscal year 2026 enhancements to the System Analysis Module (SAM) for modeling fission product transport in liquid-fueled molten salt reactors (MSRs). The work advances three principal areas: noble gas transport, noble metal deposition, and user interface improvements. The noble gas transport capability integrates drift-flux gas transport, Henry’s law two-film interphase mass transfer with pressure-based nucleation suppression, Knudsen-regime pore diffusion into porous graphite with a conjugate salt-graphite interface constraint, built-in material properties, five Sherwood-number mass transfer correlations including three derived from high-fidelity NekRS simulations, and xenon-135 reactivity feedback through SAM’s point-kinetics model. This work also presents a comprehensive verification test suite, including new analytically verified cases for pressure-dependent onset of interphase gas transfer in a stagnant vertical pipe, a postulated FLiBe-graphite Xe extraction permeator, a gravity riser with a fission-product source, and a descending pipe with gas redissolution driven by hydrostatic pressure. A machine learning framework for bubble rise velocity prediction in molten salt systems is developed and benchmarked on molten-salt and diverse aqueous bubble datasets. The best-performing fine-tuned transfer-learning networks achieve an 82% reduction in RMSE relative to the Clift correlation, and is implemented directly in SAM. The noble metal transport capability is developed, including a liquid-wall deposition model and a gas-surface flotation mechanism that transfers insoluble particles entrained by sparging gas to wetted structures. Verification tests and demonstration cases cover the surface deposition, flotation efflux, and flotation shedding. Finally, a new [SpeciesTransport] input structure replaces positional global vectors with selfcontained, order-independent, named species blocks, simplifies the specification of multiphase species and decay chains, and remains fully compatible with existing SAM input files. Together, these developments improve the physical fidelity, verification basis, and usability of SAM for system-level analyses of fissionproduct behavior in MSRs.

Mui, Travis (ORCID:0000000303736470)↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Employing Eye Trackers to Reduce Nuisance Alarms

When process operators anticipate an alarm prior to its annunciation, that alarm loses information value and becomes a nuisance. This study investigated using eye trackers to measure and adjust the salience of alarms with three methods of gaze-based acknowledgement (GBA) of alarms that estimate operator anticipation. When these methods detected possible alarm anticipation, the alarm’s audio and visual salience was reduced. A total of 24 engineering students (male = 14, female = 10) aged between 18 and 45 were recruited to predict alarms and control a process parameter in three scenario types (parameter near threshold, trending, or fluctuating). The study evaluated whether behaviors of the monitored parameter affected how frequently the three GBA methods were utilized and whether reducing alarm salience improved control task performance. The results did not show significant task improvement with any GBA methods (F(3,69) = 1.357, p = 0.263, partial η 2 = 0.056). However, the scenario type affected which GBA method was more utilized (X 2 (2, N = 432) = 30.147, p < 0.001). Alarm prediction hits with gaze-based acknowledgements coincided more frequently than alarm prediction hits without gaze-based acknowledgements (X 2 (1, N = 432) = 23.802, p < 0.001, OR = 3.877, 95% CI 2.25–6.68, p < 0.05). Participant ratings indicated an overall preference for the three GBA methods over a standard alarm design (F(3,63) = 3.745, p = 0.015, partial η 2 = 0.151). This study provides empirical evidence for the potential of eye tracking in alarm management but highlights the need for additional research to increase validity for inferring alarm anticipation.

99 - GENERAL AND MISCELLANEOUS↗

An Analytic Formula for Entraining CAPE in Midlatitude Storm Environments

Abstract This article introduces an analytic formula for entraining convective available potential energy (ECAPE) with an entrainment rate that is determined directly from an environmental sounding, rather than prescribed by the formula user. Entrainment is connected to the background environment using an eddy diffusivity approximation for lateral mixing, updraft geometry assumptions, and mass continuity. These approximations result in a direct correspondence between the storm-relative flow and the updraft radius and an inverse scaling between the updraft radius squared and entrainment rate. The aforementioned concepts, combined with the assumption of adiabatic conservation of moist static energy, yield an explicit analytic equation for ECAPE that depends entirely on state variables in an atmospheric profile and a few constant parameters with values that are established in past literature. Using a simplified Bernoulli-like equation, the ECAPE formula is modified to account for updraft enhancement via kinetic energy extracted from the cloud’s background environment. CAPE and ECAPE can be viewed as predictors of the maximum vertical velocity w max in an updraft. Hence, these formulas are evaluated using w max from past numerical modeling studies. Both of the new formulas improve predictions of w max substantially over commonly used diagnostic parameters, including undiluted CAPE and ECAPE with a constant prescribed entrainment rate. The formula that incorporates environmental kinetic energy contribution to the updraft correctly predicts instances of exceedance of by w max , and provides a conceptual explanation for why such exceedance is rare among past simulations. These formulas are potentially useful in nowcasting and forecasting thunderstorms and as thunderstorm proxies in climate change studies. Significance Statement Substantial mixing occurs between the upward-moving air currents in thunderstorms (updrafts) and the surrounding comparatively dry environmental air, through a process called entrainment. Entrainment controls thunderstorm intensity via its diluting effect on the buoyancy of air within updrafts. A challenge to representing entrainment in forecasting and predictions of the intensity of updrafts in future climates is to determine how much entrainment will occur in a given thunderstorm environment without a computationally expensive high-resolution simulation. To address this gap, this article derives a new formula that computes entrainment from the properties of a single environmental profile. This formula is shown to predict updraft vertical velocity more accurately than past diagnostics, and can be used in forecasting and climate prediction to improve predictions of thunderstorm behavior and impacts.

54 ENVIRONMENTAL SCIENCES↗

Assessment of Readout Techniques for Passive Monitors

This fiscal year (FY) 2023 report on passive temperature sensors covers two main objectives: to demonstrate that the optical dilatometer can successfully process disc shaped silicon carbide (SiC) temperature monitors (TMs), and to demonstrate proof of concept for using the capacitance readout method to read printed melt wires. The SiC objective was successfully met by annealing and analyzing, via optical dilatometry, all eight 3-mm SiC discs provided by the Nuclear Science User Facilities (NSUF) Idaho State University (ISU) Nanostructured Steels for Enhanced Radiation Tolerance (N SERT) experiment, which was irradiated at Idaho National Laboratory (INL)’s Advanced Test Reactor (ATR). Per the ISU N SERT experiment, capsule 1 (KGT 3828 1 and KGT 3828-2) had a design temperature of 300°C +/- 50°C and an exposure of 2 dpa +/- 10%; capsule 2 (KGT 4600 and KGT 4609) had a design temperature of 300°C +/- 50°C and an exposure of 6 dpa +/- 10%; capsule 3 (KGT 4639 C and KGT 4639-D) had a design temperature of 500°C +/- 50°C and an exposure of 6 dpa +/- 10%; and capsule 4 (KGT 3841 3 and KGT 3841 4) had a design temperature of 500°C +/- 50°C and an exposure of 2 dpa +/- 10%. The target exposure rates, in dpa, are the neutron damage for various types of nanostructured steels. All but three SiC TMs (KGT 4600, KGT 4639 D, and KGT 3841 4) revealed averaged peak irradiation temperatures that fell within the design temperature ranges. The three SiC TMs that did not fall within the design temperatures ranges were at least 100°C below that target temperature. Furthermore, SiC TM KGT 3841 C revealed two irradiation regimes: one closer to the 300°C design temperature, and the other closer to the 500°C design temperature. Also, all the SiC TMs’ averaged peak irradiation temperatures came in anywhere between 20°C and 240°C below the irradiation temperatures predicted by the thermal models. This showed the optical dilatometry method to be a reliable and less time intensive process for determining averaged peak irradiation temperatures from passive SiC TMs such as rods and discs. Under the Advanced Sensors and Instrumentation (ASI) program in FY-23, Boise State University (BSU) proposed to demonstrate proof of concept for using a capacitance readout technique applicable to printed melt wires; however, they were stymied by the complexity of the capacitance readout method. In support of the BSU work, INL developed an additively manufactured (AM) ceramic package for encapsulating the new melt wires. Inks were synthesized at BSU that used new protocols rather than following previously established protocols implemented at INL, and testing of various temperatures was conducted at BSU to evaluate the melting behaviors of the printed melt wires. The result was that the capacitance readout technique showed promise but also created more challenges than originally anticipated. For example, the tin ink synthesized at BSU showed unusual melting behaviors that did nothing to enhance the performance of the final printed melt wire prototype in terms of the capacitance readout method. To make the proof of concept work when applied to the printed melt wires, the ASI program would need to invest further resources and time. Consequently, the program is not planning to continue this proof of concept work in FY-24, based on the progress and findings achieved in FY-23.

36 MATERIALS SCIENCE↗

IDAES-PSE 2.6.0 Release

The Institute for the Design of Advanced Energy Systems (IDAES) Integrated Platform is a versatile computational environment offering extensive process systems engineering (PSE) capabilities for optimizing the design and operation of complex, interacting technologies and systems. IDAES enables users to efficiently search vast, complex design spaces to discover the lowest cost solutions while supporting the full process modeling lifecycle, from conceptual design to dynamic optimization and control. The extensible, open platform empowers users to create models of novel processes and rapidly develop custom analyses, workflows, and end-user applications. IDAES-PSE 2.6.0 Release Highlights Upcoming Changes IDAES will be switching to the new Pyomo solver interface in the next release. Whilst this will hopefully be a smooth transition for most users, there are a few important changes to be aware of. The new solver interface uses a different version of the IPOPT writer (“ipopt_v2”) and thus any custom configuration options you might have set for IPOPT will not carry over and will need to be reset. By default, the new Pyomo linear presolver will be activated with ipopt_v2. Whilst are working to identify any bugs in the presolver, it is possible that some edge cases will remain. IDAES will begin deploying a new set of scaling tools and APIs over the next few releases that make use of the new solver writers. The old scaling tools and APIs will remain for backward compatibility but will begin to be deprecated. New Models, Tools and Features New Intersphinx extension automatically linking Jupyter notebook examples to project documentation New end-to-end diagnostics example demonstrated on a real problem New complementarity formulation for VLE with cubic equations of state, backward compatibility for old formulation New solver interface with presolve (ipopt_v2) in support of upcoming changes to the initialization and APIs methods, with default set to ipopt to maintain backwards compatibility; this will deprecate once all examples have been updated New forecaster and parameterized bidder methods within grid integration library Updated surrogates API and examples to support Keras 3, with backwards compatibility for older formats such as TensorFlow SavedModel (TFSM) Updated costing base dictionary to include the 2023 cost year index value Updated ProcessBlock to include information on the constructing block class Updated Flowsheet Visualizer to allow visualize() method to return value and functions Bug Fixes Fixed bug in the Modular Property Framework that would cause errors when trying to use phase-based material balances with phase equilibria. Fixed bug in Modular Properties Framework that caused errors when initializing models with non-vapor-liquid phase equilibria. Fixed typos flagged by June update to crate-ci/typos and removed DMF-related exceptions Minor corrections of units of measurement handling in power plant waste/transport costing expressions, control volume material holdup expressions, and BTX property package parameters Fixed throwing >7500 numpy deprecation warnings by replacing scalar value assignment with element extraction and item iteration calls Testing and Robustness Migrated slow tests (>10s) to integration, impacting test coverage but also yielding a nearly 30% decrease in local test runtime Pinned pint to avoid issues with older supported Python versions Pinned codecov versions to avoid tokenless upload behavior with latest version Bumped extensions to version 3.4.2 to allow pointing to non-standard install location Deprecations and Removals Python 3.8 is no longer supported. The supported Python versions are 3.9 through 3.12 The Data Management Framework (DMF) is no longer supported. Importing idaes.core.dmf will cause a deprecation warning to be displayed until the next release The SOFC Keras surrogates have been removed. The current version of the SOFC surrogate model in the examples repository is a PySMO Kriging model.

AS↗

TRACER Carbonaceous Aerosols Thrust – University of California, Davis Field Campaign Report

The broader U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s TRacking Aerosol Convection interactions ExpeRiment (TRACER) campaign aims to increase our understanding of convective cloud life cycles and aerosol-convection interactions. Our TRACER Carbonaceous Aerosols Thrust-University of California, Davis (TRACER-CAT-UCDavis) study complemented these broader aims by characterizing and quantifying the optical properties and composition of carbonaceous aerosols during part of the TRACER intensive sampling period (July 1- July 31, 2022) at the first ARM Mobile Facility (AMF1) main site (M1) in La Porte, Texas. Our measurements complemented the suite of instrumentation already provided by the AMF1, expanding the capabilities through deployment of unique, state-of-the-science instrumentation. The instrumentation included: (i) two cavity-attenuated phase shift spectroscopy single-scatter albedo (CAPS-SSA) instruments operating at 530 nm and 630 nm, and that were modified to characterize particle light absorption, extinction, and scattering at elevated humidities; (ii) the UC Davis dual-wavelength cavity ringdown-photoacoustic spectrometer (CRD-PAS), which characterizes dry particle extinction and absorption at 405 nm and 532 nm; (iii) a soot particle aerosol mass spectrometer (SP-AMS) that operated in “laser only” mode that characterized the size-dependent compositions of black carbon (BC)-containing particles; (v) a thermal denuder, to remove coatings on particles; and (vi) a scanning electrical mobility sizer (SEMS), to characterize particle mobility diameters from 10-1300 nm. Our measurements occurred alongside complementary observations made by Los Alamos National Laboratory (LANL) during the TRACER-CAT-LANL study, including a humidified CAPS-SSA instrument operating at 450 nm. Our primary scientific interest is in understanding the relationship between particle composition and light absorption, with a particular focus on the influence of water uptake. While it is known that coatings on BC can enhance absorption, the extent to which this occurs in the atmosphere and the specific role that water plays as a coating remain unclear. The TRACER-CAT-UCDavis measurements were made with near-complete coverage for the CRD-PAS, SP-AMS, and SEMS throughout the intensive period. The UC Davis humidified CAPS-SSA instruments had significant challenges with operation owing to the demanding conditions (large temperature fluctuations, high humidity), exacerbated by supply chain issues that delayed resolution of these challenges. However, the humidified CAPS-SSA instrument operated by LANL operated throughout the intensive period with near-complete coverage. The dry light extinction measurements from the CRD-PAS measurements and the LANL CAPS-SSA exhibited a good correlation, although the CAPS-SSA systematically measured greater extinction values than expected. While all instruments, with the exception of an aerodynamic particle sizer (APS), measured behind a common particulate matter (PM)2.5 μm cyclone, the greater extinction measured by the LANL CAPS-SSA compared to the CRD-PAS may have resulted from different losses of larger particles in the sampling lines from the cyclone to the instruments; the tubing length was shorter from the cyclone to the LANL CAPS-SSA, consistent with this idea. A summary of the TRACER-CAT-UCDavis measurements, along with some of the TRACER-CAT-LANL measurements, are shown in the figure below. Notably, there were periods when the contributions of presumed dust were substantial and even dominated the observed light extinction and absorption. Also, there was a clear shift in the behavior of submicron particles from before July 16, 2022 to after, with the prior period exhibiting regular episodes of new particle formation and the latter period exhibiting rapid variations in the concentrations of small particles.

54 ENVIRONMENTAL SCIENCES↗

MARVEL Reactor Fuel Performance Report (Rev.2)

The Microreactor Applications Research Validation and EvaLuation (MARVEL) project is producing a high temperature liquid metal-cooled nuclear test bed at Idaho National Laboratory (INL) to ultimately improve the integration of microreactors to end-user applications. This ambitious effort seeks to design, authorize, construct, test, and operate the reactor within five years. In order to construct and operate the MARVEL reactor in a timely manner, the system will utilize materials and component designs which have already been used, qualified, or licensed from previous reactors. The MARVEL reactor will be located at the INL Transient Reactor Test (TREAT) facility in the north high-bay equipment pit and will use the existing 304 stainless steel-clad U-ZrH1.6 pin-type fuel system developed by General Atomics and purchased from TRIGA International. This fuel has been previously qualified under the United States Department of Energy’s (US DOE) Reduced Enrichment for Research and Test Reactors (RERTR) Program. Even though the regulator of the MARVEL reactor is the US DOE, the standards and overall approach recommended by the Nuclear Regulatory Commission is well-defined and utilized here. Following NUREG-1537 regulatory guidance, this report documents the authorization case for the MARVEL fuel system’s application to MARVEL and establishes stable and predictable fuel performance during the most thermophysically unfavorable conditions achievable in the MARVEL reactor. To that end, this report provides a comprehensive survey of the known thermophysical properties, performance, and quantitative relationships associated with the MARVEL reactor fuel element and uses this information to determine its mechanical integrity and risk of reaching unacceptable conditions during the most extreme accident scenarios predicted for the reactor using the most conservative assumptions available. The information contained herein is compiled from a combination of historical reports and peer reviewed scientific publication manuscripts. Known mechanisms under which the fuel is susceptible to failure are highlighted and compared to conditions that could exist in the MARVEL reactor during an unanticipated transient or accident scenario. The two scenarios considered for analysis in this report are (1) an unprotected loss of flow accident and (2) a hypothetical unprotected loss of coolant accident during the loss of flow accident. Preliminary 2D steady-state analyses herein indicate that both fuel-cladding chemical interactions and fuel-cladding mechanical interactions are negligible throughout the fuel’s operational cycle under both normal and high temperature accident scenario conditions. Although higher fidelity 3D time-dependent modeling and simulations are planned, the following may be concluded presently. The MARVEL fuel element maintains its geometric stability and structural integrity during the most extreme accident scenarios predicted for the MARVEL reactor. The hoop stress during the unprotected loss of flow accident reaches about -1.27 MPa; this negative stress indicates that it is compressive rather than tensile. The compressive stress is a result of the NaK pressure on the outside of the fuel element, caused by the restricted thermal expansion of the NaK coolant, exceeding the internal pressures generated inside of the fuel element. The hoop stress generated in the cladding during the unprotected loss of coolant accident reaches a maximum of about approximately 10 MPa, which is nearly an order of magnitude less than the predicted yield strength of the cladding under high-temperature accident scenario conditions. Calculations were compared with results from high performance computational simulations using BISON and are in very close agreement. A conservative MARVEL fuel meat peak temperature limit of 900 °C is recommended presently, which is about 180 °C higher than the peak fuel temperature predicted to occur during the most extreme accident. Based on the known properties and behavior of the MARVEL fuel element, the fuel successfully meets its design and safety requirements under normal and most extreme accident conditions with a large safety margin.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MARVEL Reactor Fuel Performance Report

The Microreactor Applications Research Validation and EvaLuation (MARVEL) project is producing a high temperature liquid metal-cooled nuclear test bed at Idaho National Laboratory (INL) to ultimately improve the integration of microreactors to end-user applications. This ambitious effort seeks to design, authorize, construct, test, and operate the reactor within five years. In order to construct and operate the MARVEL reactor in a timely manner, the system will utilize materials and component designs which have already been used, qualified, or licensed from previous reactors. The MARVEL reactor will be located at the INL Transient Reactor Test (TREAT) facility in the north high-bay equipment pit and will use the existing 304 stainless steel-clad U-ZrH1.6 pin-type fuel system developed by General Atomics and purchased from TRIGA International. This fuel has been previously qualified under the United States Department of Energy’s (US DOE) Reduced Enrichment for Research and Test Reactors (RERTR) Program. Even though the regulator of the MARVEL reactor is the US DOE, the standards and overall approach recommended by the Nuclear Regulatory Commission is well-defined and utilized here. Following NUREG-1537 regulatory guidance, this report documents the authorization case for the MARVEL fuel system’s application to MARVEL and establishes stable and predictable fuel performance during the most thermophysically unfavorable conditions achievable in the MARVEL reactor. To that end, this report provides a comprehensive survey of the known thermophysical properties, performance, and quantitative relationships associated with the MARVEL reactor fuel element and uses this information to determine its mechanical integrity and risk of reaching unacceptable conditions during the most extreme accident scenarios predicted for the reactor using the most conservative assumptions available. The information contained herein is compiled from a combination of historical reports and peer reviewed scientific publication manuscripts. Known mechanisms under which the fuel is susceptible to failure are highlighted and compared to conditions that could exist in the MARVEL reactor during an unanticipated transient or accident scenario. The two scenarios considered for analysis in this report are (1) an unprotected loss of flow accident and (2) a hypothetical unprotected loss of coolant accident during the loss of flow accident. Preliminary 2D steady-state analyses herein indicate that both fuel-cladding chemical interactions and fuel-cladding mechanical interactions are negligible throughout the fuel’s operational cycle under both normal and high temperature accident scenario conditions. Although higher fidelity 3D time-dependent modeling and simulations are planned, the following may be concluded presently. The MARVEL fuel element maintains its geometric stability and structural integrity during the most extreme accident scenarios predicted for the MARVEL reactor. The hoop stress during the unprotected loss of flow accident reaches about -1.27 MPa; this negative stress indicates that it is compressive rather than tensile. The compressive stress is a result of the NaK pressure on the outside of the fuel element, caused by the restricted thermal expansion of the NaK coolant, exceeding the internal pressures generated inside of the fuel element. The hoop stress generated in the cladding during the unprotected loss of coolant accident reaches a maximum of about approximately 10 MPa, which is nearly an order of magnitude less than the predicted yield strength of the cladding under high-temperature accident scenario conditions. Calculations were compared with results from high performance computational simulations using BISON and are in very close agreement. A conservative MARVEL fuel meat peak temperature limit of 900 °C is recommended presently, which is about 180 °C higher than the peak fuel temperature predicted to occur during the most extreme accident. Based on the known properties and behavior of the MARVEL fuel element, the fuel successfully meets its design and safety requirements under normal and most extreme accident conditions with a large safety margin.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Changes in SSL Device Efficiency and Optical Performance Under Accelerated Aging Conditions

Lighting application efficiency (LAE) describes the efficient delivery of light from the light source to the lighted task and is viewed as a new frontier—increasing energy savings with solid-state lighting (SSL) technologies. The framework for LAE that is proposed by the U.S. Department of Energy (DOE) consists of four major elements: light source efficiency, optical delivery efficiency, spectral efficiency, and intensity effectiveness. This report focuses on a sampling of the available SSL products that can be broadly defined as having modified spectral output because the method of spectra modification has a significant impact on light source efficiency and long-term optical delivery and spectral efficiencies. This report focused on the changes in light source, optical delivery, and spectral efficiencies that occur during aging of SSL devices. An accelerated stress test (AST) regiment was developed for the devices under test (DUTs) examined in this report to provide insights into how the performance of SSL devices change with aging. The AST protocols demonstrate that the SSL products discussed in this report often reduce light source efficiency to achieve different spectral characteristics. In addition, aging of the optical components (e.g., lenses, solder masks) in SSL devices can produce increased light absorption, which negatively impacts optical delivery efficiency and light source efficiency. The modified spectral outputs of the selected SSL products discussed in this report come in a variety of form factors and achieve enhanced optical performance by using a variety of methods. All of the products examined in this study use mid-power light-emitting diodes (MP-LEDs), although the number, configuration, phosphor content, and light-emitting diode (LED) pump of the MP-LEDs differ. Product MS-1 is a 60-watt (W) replacement A19 lamp with a hermetically sealed glass globe, which contains an embedded optical filter to absorb green and yellow emissions, thereby creating a “sunlike” modified spectrum. Product MS-2 is a 60-W replacement A19 lamp with 30 MP-LEDs, and it uses a violet LED pump, along with green and red phosphor emissions, to produce a “healthy” spectrum. This spectrum omits blue emissions in an effort to reduce melanopic lux. Product MS-3 is an LED module consisting of 21 MP-LEDs that use a violet LED pump, along with blue, green, and red phosphors, to produce a “sunlike” spectrum. Products MS-4 and MS-5 are both 6-inch (in) downlights that use a manual switching mechanism so that users can select application-specific correlated color temperatures before installation. Products MS-4 and MS-5 both contain two LED primaries (2,700 Kelvin [K] and 5,000 K) for spectral tuning. Product MS-4 contains 12 MP-LEDs for each LED primary, and Product MS-5 contains 10 MP-LEDs for each LED primary. This report summarizes the overall findings from up to 8,000 hours (hrs) of AST on the lamp DUTs (Products MS-1 and MS-2); up to 5,000 hrs of AST on the LED light engine DUTs (Product MS-3); and up to 7,000 hrs of AST on the downlight DUTs (Products MS-4 and MS-5). The AST procedures used in this study included a room temperature operational life (RTOL) test, an operational life test conducted at 45 degrees Celsius (°C; 45OL) test, an operational life test conducted at 75°C (75OL), a wet high-temperature operational life test performed at 65°C and 90% relative humidity (6590), and a wet high-temperature operational life test performed at 75°C and 75% relative humidity (7575). The AST procedures used for Products MS-1 and MS-2 were RTOL, 45OL, and 6590. The AST procedures used for Products MS-3, MS-4, and MS-5 were RTOL, 75OL, and 7575. During the ASTs described herein, separate populations of each product (three DUTs in each population for Products MS-1, MS-2, MS-4, and MS-5; four DUTs in each population for Product MS-3) were subjected to power cycling of 1 hr on and 1 hr off. The key findings from this study include the following. Enhanced optical performance came at the cost of reduced light source efficiency for the lamps and light engines examined in this study. The optical filter used to produce a “sunlike” spectrum for Product MS-1 reduced light source efficiency by 26%, from 113 lumens per watt (lm/W) to 85 lm/W. Products MS-2 and MS-3 that used a violet-pumped LED to achieve “healthy” and “sunlike” enhanced optical performance, respectively, suffered the largest reduction in initial light source efficiency (49 lm/W for Product MS-2 and 68 lm/W for Products MS-3) perhaps because of the use of violet LED as the optical pump. Product MS-2 also had the poorest color fidelity because of undersaturation of blues and oversaturation of greens and yellows. Chromaticity maintenance of the products in this study was generally good, with parametric failure only occurring for one product at one AST condition (i.e., Product MS-3 at 7575). The chromaticity shift for Product MS-3 in 7575 test conditions resulted from reduced emissions of the broad green and red phosphors used to mimic sunlight in the 500–750 nanometer (nm) range. As a result of these phosphor emission losses, chromaticity shifted toward the more stable violet-pumped LED and blue phosphor. Although chromaticity maintenance was acceptable for most products tested, different chromaticity shift mechanisms were observed for temperature and humidity tests compared with temperature alone for Products MS-1, MS-2, and MS-3. For Product MS-1, a relative increase in green emissions was observed with humidity, which may indicate humidity-accelerated degradation of the optical filter at green wavelengths (optical delivery efficiency reduction) or degradation of the emitters in the red region (spectral efficiency reduction). The violet-pumped products (i.e., MS-2 and MS-3) exhibited different chromaticity shift behavior in the temperature-humidity environments, with Product MS-2 shifting generally yellow because of photo-induced oxidation of the plastic globe (i.e., a reduction of optical delivery efficiency) and Product MS-3 shifting toward violet and blue emitters because of faster loss of emission from green and red phosphors (i.e., a reduction in spectral efficiency). Because of an initial drop in power consumption, the light source efficiency of downlights (Products MS-4 and MS-5) increased at RTOL throughout the test duration. The light source efficiency initially increased during 75OL until a decay in luminous flux maintenance (LFM) dominated light source efficiency, whereas the light source efficiency decreased for the entire 7575 test duration. It was found that increasing the ambient environment of an SSL device from 25°C to 75°C decreases the LFM by 2.7 to 5.5, depending on design of the SSL device. Adding humidity to the system (75OL to 7575) was found to decrease LFM by another factor of approximately 3.0. A common location of failure was identified for the downlights (Products MS-4 and MS-5) operated in the 7575 environment. This failure abruptly occurred between 3,000 to 5,000 hrs of testing on the film capacitor of the electromagnetic interference (EMI) filter near the diode bridge for 11 of the 12 downlights. It is likely that this failure was caused by a combination of the high electrical voltage across the capacitor, the location of the capacitor near the heat sources (e.g., transformers, diode bridges, power resistors), and the high stress environment of 7575. Longer test times are needed to fully understand the LFM, luminous efficacy changes, and chromaticity shifts for some of the products. Because of the high reliability, light source efficiency, and spectral tuning capabilities of LEDs, the expectations of LAE for SSL products are greatly increased over traditional lighting products. The data gathered in this report begin to provide an understanding of the tradeoffs that current SSL products undergo when optimizing the different efficiency elements of LAE. As discussed in this report, the findings from the tests conducted show that the optimization of spectral efficiency can come at the cost of initial light source efficiency. Furthermore, the introduction of violet LEDs can promote long-term optical delivery efficiency degradation, and the introduction of optical filters or new phosphors can lead to unwanted spectral efficiency changes because the ratio of phosphor emitters changes with aging. The data presented in this report also identified a common failure location in 6-in downlights. The results regarding long-term behavior of the modified spectra devices studied provide valuable information about changes to the light source, spectral, and optical delivery efficiencies as the devices age. This information can be used to improve future SSL designs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗