Search NASA⌕ Search

SEARCH · Search NASA

Results for “VACUUM SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Exploration Extravehicular Mobility Unit (xEMU) Chamber B Thermal Vacuum “Suit 2” Pressure Garment System Test Article Results

NASA’s Exploration Extravehicular Mobility Unit (xEMU) is the government reference next-generation spacesuit design and is engineered to protect astronauts from extreme lunar environmental temperatures. To evaluate the xEMU hardware thermal requirements, the xEMU Testing Team invented, designed, and executed a dual-suit, uncrewed thermal vacuum (TVAC) test at Johnson Space Center’s (JSC) Chamber B. This paper details the test results from the “Suit 2” Pressure Garment System (PGS) test article. The primary objective of the “Suit 2” PGS test article was to evaluate system-level suit heat leak and Environmental Protection Garment (EPG) thermal performance. Eleven unique thermal profiles were tested including both cold and hot environmental cases over the course of five continuous days of testing. The radiative thermal environment was controlled through exposure to liquid-nitrogen shrouds on the chamber walls and a heater cage surrounding the test article. This paper will principally focus on system-level thermal results from the “Suit 2” PGS test article. This paper will examine data collected from one-hundred and seventy thermocouples located in critical locations inside and outside of the suit, as well as seven resistance thermometers (RTDs) for calorimetry to determine total heat flux in and out of the suit. The test data will be compared against the system-level PGS thermal models for model validation. To conclude, this paper will address knowledge gaps presented by unmanned xPGS thermal vacuum testing and the current state of lunar xPGS thermal modeling and testing.

xEMU↗

Flexible storage medium for write-once optical tape

A write-once data storage media was developed which is suitable for optical tape applications. The media is manufactured using a continuous film process to deposit a ternary alloy of tin, bismuth, and copper. This laser sensitive layer is sputter deposited onto commercial plastic web as a single-layer thin film. A second layer is sequentially deposited on top of the alloy to enhance the media performance and act as an abrasion resistant hard overcoat. The media was observed to have laser write sensitivities of less than 2.0 njoules/bit, carrier-to-noise levels of greater than 50dB's, modulation depths of approximately 100 percent, read-margins of greater than 35, uniform grain sizes of less than 200 Angstroms, and a media lifetime that exceeds 10 years. Prototype tape media was produced for use in the CREO drive system. The active and overcoat materials are first sputter deposited onto three mil PET film in a single pass through the vacuum coating system, and then converted down into multiple reels of 35mm x 880m tape. One mil PET film was also coated in this manner and then slit and packaged into 3480 tape cartridges.

Strandjord, Andrew J. G.↗

A Magnetron Sputter Deposition System for the Development of Multilayer X-Ray Optics

The proposal objective is to establish the capability to deposit multilayer structures for x-ray, neutron, and EUV optic applications through the development of a magnetron sputtering deposition system. A specific goal of this endeavor is to combine multilayer deposition technology with the replication process in order to enhance the MSFC's position as a world leader in the design of innovative X-ray instrumentation through the development of full shell replicated multilayer optics. The development of multilayer structures is absolutely necessary in order to advance the field of X-ray astronomy by pushing the limit for observing the universe to ever increasing photon energies (i. e. up to 200 keV or higher); well beyond Chandra (approx. 10 keV) and NuStar's (approx. 75 keV) capability. The addition of multilayer technology would significantly enhance the X-ray optics capability at MSFC and allow NASA to maintain its world leadership position in the development, fabrication and design of innovative X-ray instrumentation which would be the first of its kind by combining multilayer technology with the mirror replication process. This marriage of these technologies would allow astronomers to see the universe in a new light by pushing to higher energies that are out of reach with today's instruments.To this aim, a magnetron vacum sputter deposition system for the deposition of novel multilayer thin film X-ray optics is proposed. A significant secondary use of the vacuum deposition system includes the capability to fabricate multilayers for applications in the field of EUV optics for solar physics, neutron optics, and X-ray optics for a broad range of applications including medical imaging.

Broadway, David↗

Rubber-coated bellows improves vibration damping in vacuum lines

Compact-vibration damping systems, consisting of rubber-coated metal bellows with a sliding O-ring connector, are used in vacuum lines. The device presents a metallic surface to the vacuum system and combines flexibility with the necessary stiffness. It protects against physical damage, reduces fatigue failure, and provides easy mating of nonparallel lines.

Hegland, D. E.↗

Space Technology for Crop Drying

McDonnell Douglas came up with a new method of drying agricultural crops derived from vacuum chamber technology called MIVAC, a compression of microwave vacuum drying system. A distant cousin of the home microwave oven, MIVAC dries by means of electrically- generated microwaves introduced to a crop-containing vacuum chamber. Microwaves remove moisture quickly and the very low pressure atmosphere in the chamber permits effective drying at much lower than customary temperatures. Thus energy demand is doubly reduced by lower heat requirement and by the shorter time electric power is needed.

Source record↗

Thermal vacuum testing of flexible radiator systems

Flexible fin radiators are being developed to meet spacecraft requirements of light weight, compact launch volume, modular growth, reusability, and the capability of an on-orbit deployment and retraction. Two prototype versions of deployable/retractable, flexible finspace radiators (soft and hard tube) were tested simultaneously under thermal vacuum conditions. A map of the heat rejection performance of each radiator panel under various environmental conditions is given. The soft tube radiator deployment system demonstrated minimal gas pressure and was capable of maintaining partial deployment; temperature control was achieved by varying the deployment length. The radiator could be recovered after an inadvertant freezing of the coolant in the Teflon tube. The hard tube radiator deployment mechanism performed adequately throughout the testing, but did exhibit some undesirable performance characteristics. The hard tube radiator pressure drop was higher than expected, but was not affected by the length of deployment. The radiator operated at less than full deployment, and the manifolds were found to have a significant effect on heat rejection. At low-load conditions, the hard tube radiator appeared to bypass its deployed area.

Rankin, G.↗

Does the International Space Station Leak DNA? Preliminary Results from the ISS External Microorganisms Payload

Existing crewed spacecraft like the ISS (International Space Station) leak by design. The ISS routinely releases gas to maintain life support systems and when astronauts exit the station to perform space walks. The chemical component of this leakage is well characterized, but the biological components are not. The ISS is not subject to planetary protection requirements, but planned missions to Mars will use similar systems and will be subject to planetary protection requirements. If detectable microorganisms are escaping through vents and or airlocks we may need to redesign our crewed habitats to minimize this type of contamination. To test the hypothesis that microorganisms from inside ISS are detectable on exterior surfaces an astronaut used the ISS External Microorganisms sampling kit (Rucker et al. 2018) to sample exterior surfaces of the ISS during an EVA (Extra Vehicular Activity) in January of 2025. These samples were returned to Earth for DNA extraction and sequencing. We successfully, extracted and sequenced bacterial, fungal and viral DNA from these samples that was not present in the negative controls. These results should help NASA refine the planetary protection requirements for crewed missions. Methods: The samples were collected using sterile, DNA free, buccal swabs (23 mm. diameter) housed in custom canisters. Each canister uses a 0.2 μm Teflon filter to maintain sterility as the caddy, holding 8 swabs moves in and out of vacuum. The astronaut sampled the: 1) airlock vestibule, 2) airlock thermal cover, 3) a gap in the micrometeorite shielding near the airlock, 4) a handrail near the airlock, 5) the Carbon Dioxide Removal Assembly vent, and 6) the Vacuum Exhaust System vent. The seventh swab was exposed to vacuum during the EVA without touching it to a surface. The eighth swab, a negative control, was not opened until the caddy returned to Earth. DNA was extracted from the swabs using a QIamp UCP Pathogen kit and prepared for sequencing on an Aviti (Element Biosciences) sequencer (Arslan et al. 2024). The resulting sequences were analyzed using the EDGE Bioinformatics platform (Li et al. 2017). The sequences were analyzed individually using tools like BLAST, GOTTCHA2, Kraken2, and PanGIA. The data were also assembled into metagenome assembled genomes) using tools like CONCOCT, MaxBin2 and MetaBAT2. Results: We successfully extracted and sequenced bacterial, archaeal, fungal and viral DNA from all seven samples. The handrail swab had the lowest number of reads (768,651) and the airlock thermal cover had the highest number of reads (8,819,230). These samples contain DNA from human associated bacteria (e.g. Crynebacterium riegelii ), fungi (.e.g. Penicillium rubens ), and viruses (e.g Alphapapillomavirus ). Conclusion: Preliminary interpretation suggest that the airlock and the space suits themselves are the largest sources of contaminant DNA. Most if not all of the DNA is from organisms known to be present inside the ISS. Vents attached to life support systems may be a lesser source of biological contamination. Further analysis should help NASA address planetary protection knowledge gaps for crewed missions.

Aaron B Regberg↗

Exploration Extravehicular Mobility Unit (xEMU) Chamber B Thermal Vacuum “Suit 2” Pressure Garment System Hardware and Test Design

NASA’s Exploration Extravehicular Mobility Unit (xEMU) is the government reference next-generation space suit design and is engineered to protect astronauts from extreme lunar environmental temperatures. To evaluate the xEMU hardware thermal requirements, the xEMU Testing Team invented, designed, and executed a dual-suit, uncrewed thermal vacuum (TVAC) test at Johnson Space Center’s (JSC) Chamber B. This paper details the test hardware design and test methodology for the “Suit 2” Pressure Garment System (PGS) test article. The uncrewed “Suit 2” PGS test article consisted of a full PGS assembly with simulated Portable Life Support System (PLSS) functionality provided by test equipment, including a ventilation loop and two distinct thermal control loops. This paper will discuss in depth the test hardware design, including internal suit thermal boundary simulation, sensor quantity and placement, test support equipment rigs for gas flow, water flow, and power. Custom hardware designed to add additional penetrations to the suit or provide additional interfaces for sensors will also be discussed. This paper will also address the assembly and integration sequence for the test article. In addition to test hardware design, this paper will provide insights into the test methodology for this test article, including a discussion of thermal steady-state testing, simultaneous dual suit thermal vacuum testing, and hazard mitigation and controls.

xEMU↗

A fixed collector employing reversible vee-trough concentrator and a vacuum tube receiver for high temperature solar energy systems

A solar heat collection system employing non-tracking reflectors integrated with a fixed vacuum tube receiver which achieves modest year-round concentration (about 2) of the sunlight at low capital costs is discussed. The axis of the vee-trough reflector lies in a east-west direction and requires reversal of the reflector surfaces only twice a year without disturbing the receiver tubes and associated plumbing. It collects most of the diffuse flux. The vacuum tube receiver with selective absorber has no convection losses while radiation and conduction losses are minimal. Significant cost reductions are offered since the vee-trough can be fabricated from inexpensive polished or plastic reflector laminated sheet metal covering 2/3 of the collection area, and only about 1/3 of the area is covered with the more expensive vacuum tube receivers. Thermal and economic performance of the vee-trough vacuum tube system, year-round variation of the concentration factor, incident flux, useful heat per unit area at various operation temperatures and energy cost estimates are presented. The electrical energy cost is estimated to be 77 mills/kWh, and the system construction cost is estimated to be $1140/kWe.

Selcuk, M. K.↗

Space simulation experiments on reaction control system thruster plumes

A space simulation procedure was developed for studying rocket plume contamination effects using a 5-pound bipropellant reaction control system thruster. Vacuum chamber pressures of 3 x 10 to the minus 5 torr (70 miles altitude) were achieved with the thruster firing in pulse trains consisting of eight pulses (50 msec on, 100 msec off, and seven minutes between pulse trains). The final vacuum was achieved by cooling all vacuum chamber surfaces to liquid helium temperature and by introducing a continuous argon leak of 48 std. cc/sec into the test chamber. An effort was made to simulate propellant system flow dynamics corresponding to actual spacecraft mission use. Fast time response liquid flow rate measurements showed that large variations occurred in the ratio of oxidizer to fuel flow for pulse-on times up to 120 msec. These variations could lead to poor combustion efficiency and the production of contamination.

Cassidy, J. F.↗

Detection of soil microorganism in situ by combined gas chromatography mass spectrometry

Experimental tests were made to determine whether analysis of volatile metabolic products, formed in situ, is a viable procedure for an extraterrestrial life detection system. Laboratory experiments, carried out under anaerobic conditions with addition of carbon source, extended to include a variety of soils and additional substrates. In situ experiments were conducted without amendment using a vacuum sampling system.

Alexander, M.↗

Purging of a tank-mounted multilayer insulation system by gas diffusion

The investigation was conducted on a multilayer insulation (MLI) system mounted on a spherical liquid hydrogen propellant tank. The MLI consisted of two blankets of insulation each containing 15 double-aluminized Mylar radiation shields separated by double silk net spacers. The gaseous nitrogen initially contained within the MLI system and vacuum chamber was purged with gaseous helium introduced both underneath the MLI and into the vacuum chamber. The MLI panels were assumed to be purged primarily by means of gas diffusion. Overall, test results indicated that nitrogen concentrations well below 1 percent could be achieved everywhere within the MLI system. Typical times to achieve 1 percent nitrogen concentration within the MLI panels ranged from 69 minutes at the top of the tank to 158 minutes at the bottom of the tank. Four space-hold thermal performance tests indicated no significant thermal degradation of the MLI system had occurred due to the purge tests conducted. The final measured heat input attributed to the MLI was 7.23 watts as compared to 7.18 watts for the initial baseline thermal performance test.

Sumner, I. E.↗

Molecular Contamination Investigation Facility (MCIF) Capabilities

This facility was used to guide the development of ASTM E 1559 center dot Multiple Quartz Crystal Microbalances (QCMs), large sample and spectral effects capability center dot Several instrumented, high vacuum chamber systems are used to evaluate the molecular outgassing characteristics of materials, flight components and other sensitive surfaces. Test materials for spacecraft/instrument selection center.Test flight components for acceptable molecular outgas levels center dot Determine time/temperature vacuum bake-out requirements center. Data used to set limits for use of materials and specific components center. Provide Input Data to Contamination Transport Models -Applied to numerous flight projects over the past 20 years.

Soules, David M.↗

Microwave AeroGel Volatile Collector (MAGVC) Aerogel and Microwave Radiation Study

The MAGVC is a volatile extraction system that uses microwave radiation to sublimate and collect water trapped in regolith on the lunar surface It is comprised of: - Microwave source (magnetron) - Aerogel-insulated chamber (depicted as a dome) - Volatile storage system (depicted as 4 tanks) - Autonomous operating system

Aerogel↗

A unique approach to space thermal simulation

The Space Systems Lab of McDonnell Douglas developed several innovative techniques to perform the DELTA Star System thermal vacuum test. Test design constraints included an accelerated test schedule and an ambitious test plan focusing on cyclic absorbed orbital flux simulation. Test design and fabrication was completed in only 4 months, producing a 21 zone computer modeled refectorless lamp array system. Array zone control was based on discreet absorbed flux measurements, provided by adiabatic coupons conceived to eliminate the need for conventional radiometers. Test requirements, methodology, and test thermal model flight data correlation are presented.

Durant, D. Q.↗

Creating a Voyager Thermal Model 39 Years Into the Flight Mission, Along with Model Correlation and Application

After 39 years of continuous operation in space, the output of the Voyager 1 & 2 spacecraft RTG power systems has decreased to the point where managing the power margin and maintaining thermal control has become increasingly difficult. As the total power dissipation in the bus has decreased, propellant line temperatures and margin above minimum AFTs have decreased, creating risk of the hydrazine freezing (at 1.6°C). This is further complicated by the lack of existing thermal models that can be used to assess propellant tank and line temperatures. In 2014, an effort was begun to create a Voyager spacecraft thermal model for that purpose.A steady-state Thermal Desktop model has been created from scratch over the past two years. The initial thermal model development was started by Applied Sciences Laboratory (ASL) under contract to JPL. The effort relied primarily on archived manufacturing drawings, limited documentation, interviews of senior engineers who worked on the Voyager design and implementation, and the experience of the Voyager Flight Operations team.Data from the Voyager System Thermal Vacuum tests is no longer available, making it necessary to correlate the model to more recent flight data and small in-flight tests. Correlation was achieved to within ±5°C for a hot case and a cold case (both data sets from 2014). However, the flight system has very few temperature sensors directly on propellant lines. So the task remains to determine how best to use the model, in conjunction with flight data, to make sure the Voyagers can continue to fly successfully. How does one go about creating a thermal model for a spacecraft that is already launched, has limited existing mechanical description files, no thermal model in order to do a maneuver that was never planned when the spacecraft was designed?

Ledeboer, William C.↗

Creating a Voyager Thermal Model 39 Years Into the Flight Mission, Along With Model Correlation and Application

After 39 years of continuous operation in space, the output of the Voyager 1 & 2 spacecraft Radioisotope Thermoelectric Generator (RTG) power systems has decreased to the point where managing the power margin and maintaining thermal control has become increasingly difficult. As the total power dissipation in the bus has decreased, propellant line temperatures and margin above minimum Allowable Flight Temperature (AFT) have decreased, creating risk of the hydrazine freezing (at 1.6°C). This is further complicated by the lack of existing thermal models that can be used to assess propellant tank and line temperatures. In 2014, an effort was begun to create a Voyager spacecraft thermal model for that purpose. A steady-state Thermal Desktop model has been created from scratch over the past two years. Applied Sciences Laboratory (ASL) started the initial thermal model development under contract to Jet Propulsion Laboratory (JPL). The effort relied primarily on archived manufacturing drawings, limited documentation, interviews of senior engineers who worked on the Voyager design and implementation, and the experience of the Voyager Flight Operations team. Data from the Voyager System Thermal Vacuum (STV) tests is no longer available, making it necessary to correlate the model to more recent flight data and small in-flight tests. Correlation was achieved to within ±5°C for a hot case and a cold case (both data sets from 2014). However, the flight system has very few temperature sensors directly on propellant lines. Therefore, the task remains to determine how best to use the model, in conjunction with flight data, to make sure the Voyagers can continue to fly successfully.

Ledeboer, William C.↗