Search NASA⌕ Search

SEARCH · Search NASA

Results for “VAPOR JET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Ablation and Heating During Atmospheric Entry and Its Effect on Airburst Risk

Large meteoroids and asteroids entering the atmosphere endure tremendous heating from the shock heated air, and thereby lose a significant fraction of their mass during atmospheric entry a process known as ablation. The predicted evolution of the asteroids mass as it passes through the atmosphere can affect both the predicted energy deposition profile relevant to an airburst event, or the residual mass that strikes the ground in the case of an impact event. This presentation is divided roughly into two parts. In the first part, an overview of traditional models for heat transfer and ablation that are historically used in the meteor physics community is presented, and the validity in the asteroid entry regime discussed. Sensitivity analyses performed using the recently developed Fragment-Cloud Model (FCM) will be presented which show illustrate the range of sizes and entry parameters for which the predicted asteroid threat is most sensitive to the models for ablation and heat transfer. The second part of the presentation shall focus on recent work done under NASAs Asteroid Threat Assessment Project (ATAP) to develop new models for heat transfer and ablation using high-fidelity numerical simulation in concert with state-of-the-art experiments. Coupled computational fluid dynamics (CFD)radiation transport simulations preformed using the state-of-the-art entry modeling tools at NASA show that, for large meteoroids and asteroids, there can significant attenuation of the heat transfer to the surface (95 in some cases) by the products of ablation. In addition to the heat transfer, new models for the material response and ablation of asteroidal material have been developed [cite]. In the current work, we present finding from recent novel experiments performed in the arc jet facility at NASA Ames, which allows us to, in part, simulate the extreme environment experienced by the asteroid during entry. Briefly, the experimental set-up was comprised of a 1.5 conical article of machined H5 chondrite, which was exposed to a high-enthalpy flow resulting in approximately 4 kWcm2 of heating to the surface. A still frame capture from high-speed video taken during this experiment can be seen in Figure 1. In this figure, we can observe some of the major mechanisms for meteoroid ablation, such as melt flow, spallation (mechanical removal of material), and vaporization. Major findings from this, and other experiments will be discussed, as well progress on utilizing the data from the experiments to inform and develop improved models for ablation.

Asteroids↗

Experimental Behavior of Pentaborane-Air Combustion Products During Expansion in a Convergent Divergent Nozzle

In order to evaluate the post combustion behavior of boric oxide, pentaborane-air mixtures, burned to completion at a combustor pressure of 3 atmospheres, were expanded through a 7.1-inch-long convergent-divergent nozzle having a 4-inch-diameter throat and an exit-to-throat area ratio of 1.68. The experimentally determined thrust performance was in good agreement with the ideal equilibrium performance at stagnation temperatures of 3300 deg R and lower. The boric oxide vapor at the combustor exit required about 400 F deg supercooling before any condensed phase was observed. For a given thrust, fuel consumption was as much as 20 percent greater than predicted from vapor-pressure data for combustor outlet temperatures i n the vicinity of 3600 deg R. A similar result could be expected in full-scale engines, since the test combustor provided an unusually long dwell time and a highly turbulent environment. During the expansion process, the vapor (when present) did not condense to the extent predicted for an equilibrium expansion process. Moreover, condensation was observed only i n the form of small, abrupt phase changes i n the subsonic flow near the throat. Friction, due to liquid boric oxide films on the nozzle surfaces, was negligible when the surface temperature was above 800 F.

PENTABORANE↗

Characterization of Measurement Error Sources in Doppler Global Velocimetry

Doppler global velocimetry uses the absorption characteristics of iodine vapor to provide instantaneous three-component measurements of flow velocity within a plane defined by a laser light sheet. Although the technology is straightforward, its utilization as a flow diagnostics tool requires hardening of the optical system and careful attention to detail during data acquisition and processing if routine use in wind tunnel applications is to be achieved. A development program that reaches these goals is presented. Theoretical and experimental investigations were conducted on each technology element to determine methods that increase measurement accuracy and repeatability. Enhancements resulting from these investigations included methods to ensure iodine vapor calibration stability, single frequency operation of the laser and image alignment to sub-pixel accuracies. Methods were also developed to improve system calibration, and eliminate spatial variations of optical frequency in the laser output, spatial variations in optical transmissivity and perspective and optical distortions in the data images. Each of these enhancements is described and experimental examples given to illustrate the improved measurement performance obtained by the enhancement. The culmination of this investigation was the measured velocity profile of a rotating wheel resulting in a 1.75% error in the mean with a standard deviation of 0.5 m/s. Comparing measurements of a jet flow with corresponding Pitot measurements validated the use of these methods for flow field applications.

Meyers, James F.↗

Zero Gravity Cryogenic Vent System Concepts for Upper Stages

The capability to vent in zero gravity without resettling is a technology need that involves practically all uses of sub-critical cryogenics in space, and would extend cryogenic orbital transfer vehicle capabilities. However, the lack of definition regarding liquid/ullage orientation coupled with the somewhat random nature of the thermal stratification and resulting pressure rise rates, lead to significant technical challenges. Typically a zero gravity vent concept, termed a thermodynamic vent system (TVS), consists of a tank mixer to destratify the propellant, combined with a Joule-Thomson (J-T) valve to extract thermal energy from the propellant. Marshall Space Flight Center's (MSFC's) Multipurpose Hydrogen Test Bed (MHTB) was used to test both spray-bar and axial jet TVS concepts. The axial jet system consists of a recirculation pump heat exchanger unit. The spray-bar system consists of a recirculation pump, a parallel flow concentric tube heat exchanger, and a spray-bar positioned close to the longitudinal axis of the tank. The operation of both concepts is similar. In the mixing mode, the recirculation pump withdraws liquid from the tank and sprays it into the tank liquid, ullage, and exposed tank surfaces. When energy extraction is required, a small portion of the recirculated liquid is passed sequentially through the J-T expansion valve, the heat exchanger, and is vented overboard. The vented vapor cools the circulated bulk fluid, thereby removing thermal energy and reducing tank pressure. The pump operates alone, cycling on and off, to destratify the tank liquid and ullage until the liquid vapor pressure reaches the lower set point. At that point, the J-T valve begins to cycle on and off with the pump. Thus, for short duration missions, only the mixer may operate, thus minimizing or even eliminating boil-off losses.

Flachbart, Robin H.↗

Airborne photometric observations between 1.25 and 3.25 microns of late-type stars

The stars Alpha Aur (G5 III + G0 III), Alpha Boo (K2 IIIp), Alpha Ori (M1-M2 Ia-Ib), Alpha Sco (M1.5 Iab), Mu Gem (M3 III), and Alpha Her (M5 Ib-II) have been observed using interference filters in five photometric bands between 1.25 and 3.25 microns during seven flights with NASA's Lear Jet Infrared Observatory. The filters were designed to measure molecular features, primarily from CN and CO, and continuum fluxes. By calibrating the photometer in the laboratory against a stabilized blackbody source, relative flux curves have been derived. The energy distributions and the strength of molecular features are discussed. The most interesting result obtained is that the fluxes from Mu Gem and Alpha Her in the filter centered at 3.25 microns seem to be depressed by at least some tenths of a magnitude. Tentatively this depression is proposed to be due to the wings of the two vibration-rotation bands (about 2.7 microns) of hot water vapor. Since water vapor is an important opacity source and its abundance is a sensitive C/O indicator, the proposed interpretation makes renewed efforts to detect water bands in early M stars highly desirable.

Nordh, H. L.↗

Measurement Capabilities of Single-Pulse Planar Doppler Velocimetry

Preliminary investigations are described of a method that is capable of measuring instantaneous, 3-D, velocity vectors everywhere in a light sheet generated by a pulsed laser. The technique, here called Planar Doppler Velocimetry (PDV), is a variation of a new concept for velocity measurements that was called Doppler Global Velocimetry (DGV) in its original disclosure. The concept relies on the use of a narrowband laser and measurements of the Doppler shift of scattered light from particles moving with a flow. The Doppler shift is recorded as a variation in transmission through a sharp-edged spectral filter provided by iodine vapor in a cell. Entire fields of velocity can be determined by using a solid-state camera to record the intensity variations throughout the field of view. However, the implementation of DGV has been centered principally on the use of high power, continuous-wave, ion lasers and measurement times that are determined by the 30-ms framing times of standard video cameras. Hence, they provide velocity fields that are averaged in time at least over that period. On the other hand, the PDV concept described in this presentation incorporates a high energy, repetitively pulsed, Nd-YAG laser that is injection-seeded to make it narrowband and then frequency-doubled to provide light at frequencies absorbed by the iodine vapor. The duration of each pulse is less than 10 nanoseconds. When used in combination with nonstandard, scientific quality, solid state cameras, a sequence of images can be obtained that provides instantaneous velocity vectors everywhere in the field of view. The investigations described in this paper include an accurate characterization of the iodine cell spectral behavior and its influence on the PDV measurements, a derivation of the PDV signal analysis requirements, and the unique aspects of the pulsed laser behavior related to this application. In addition, PDV measurements are to be demonstrated using data from a rotating wheel target and from the flow of a subsonic jet. Initially, single optical fiber light collection and photomultiplier detectors will be substituted for solid state cameras. Those results will allow the determination of the fundamental limitations of the PDV technique without the complications of image acquisition and processing. They will then be used to provide an analysis of the measurement capabilities of PDV both in small aerodynamic research wind tunnels and in large wind tunnels designed for production airframe and propulsion testing. Future plans include the implementation of solid state cameras and the development of the required image acquisition and processing software. Eventually, the PDV technique will be applied to an aerodynamic research program related to transonic wing flutter.

McKenzie, Robert L.↗

Determination of convective diffusion heat/mass transfer rates to burner rig test targets comparable in size to cross-stream jet diameter

Two sets of experiments have been performed to be able to predict the convective diffusion heat/mass transfer rates to a cylindrical target whose height and diameter are comparable to, but less than, the diameter of the circular cross-stream jet, thereby simulating the same geometric configuration as a typical burner rig test specimen located in the cross-stream of the combustor exit nozzle. The first set exploits the naphthalene sublimation technique to determine the heat/mass transfer coefficient under isothermal conditions for various flow rates (Reynolds numbers). The second set, conducted at various combustion temperatures and Reynolds numbers, utilized the temperature variation along the surface of the above-mentioned target under steady-state conditions to estimate the effect of cooling (dilution) due to the entrainment of stagnant room temperature air. The experimental information obtained is used to predict high temperature, high velocity corrosive salt vapor deposition rates in burner rigs on collectors that are geometrically the same. The agreement with preliminary data obtained from Na2SO4 vapor deposition experiments is found to be excellent.

Gokoglu, S. A.↗

Determination of convective diffusion heat/mass transfer rates to burner rig test targets comparable in size to cross-stream jet diameter

Two sets of experiments have been performed to be able to predict the convective diffusion heat/mass transfer rates to a cylindrical target whose height and diameter are comparable to, but less than, the diameter of the circular cross-stream jet, thereby simulating the same geometric configuration as a typical burner rig test specimen located in the cross-stream of the combustor exit nozzlle. The first set exploits the naphthalene sublimation technique to detetermine the heat/mass transfer coefficient under isothermal conditions for various flow rates (Reynolds numbers). The second set, conducted at various combustion temperatures and Reynolds numbers, utilized the temperature variation along the surface of the above-mentioned target under steady-state conditions to estimate the effect of cooling (dilution) due to the entrainment of stagnant room temperature air. The experimental information obtained is used to predict high temperature, high velocity corrosive salt vapor deposition rates in burner rigs on collectors that are geometrically the same. The agreement with preliminary data obtained from Na2S04 vapor deposition experiments is found to be excellent.

Gokoglu, S. A.↗

Development of X-43A Mach 10 Leading Edges

The nose leading edge of the Hyper-X Mach 10 vehicle was orginally anticipated to reach temperatures near 4000 F at the leading-edge stagnation line. A SiC coated carbon/carbon (C/C) leading-edge material will not survive that extreme temperature for even a short duration single flight. To identify a suitable leading edge for the Mach 10 vehicle, arc-jet testing was performed on thirteen leading-edge segments fabricated from different material systems to evaluate their performance in a simulated flight environment. Hf, Zr, Si, and Ir based materials, in most cases as a coating on C/C, were included in the evaluation. Afterwards, MER, Tucson, AZ was selected as the supplier of the flight vehicle leading edges. The nose and the vertical and horizontal tail leading edges were fabricated out of a 3:1 biased high thermal conductivity C/C. The leading edges were coated with a three layer coating comprised of a SiC conversion of the top surface of the C/C, followed by a chemical vapor deposited layer of SiC, followed by a thin chemical vapor deposited layer of HfC. This paper will describe the fabrication of the Mach 10 C/C leading edges and the testing performed to validate performance.

Ohlhorst, Craig W.↗

Estimation of Enceladus Plume Density Using Cassini Flight Data

The Cassini spacecraft was launched on October 15, 1997 by a Titan 4B launch vehicle. After an interplanetary cruise of almost seven years, it arrived at Saturn on June 30, 2004. In 2005, Cassini completed three flybys of Enceladus, a small, icy satellite of Saturn. Observations made during these flybys confirmed the existence of water vapor plumes in the south polar region of Enceladus. Five additional low-altitude flybys of Enceladus were successfully executed in 2008-9 to better characterize these watery plumes. During some of these Enceladus flybys, the spacecraft attitude was controlled by a set of three reaction wheels. When the disturbance torque imparted on the spacecraft was predicted to exceed the control authority of the reaction wheels, thrusters were used to control the spacecraft attitude. Using telemetry data of reaction wheel rates or thruster on-times collected from four low-altitude Enceladus flybys (in 2008-10), one can reconstruct the time histories of the Enceladus plume jet density. The 1 sigma uncertainty of the estimated density is 5.9-6.7% (depending on the density estimation methodology employed). These plume density estimates could be used to confirm measurements made by other onboard science instruments and to support the modeling of Enceladus plume jets.

Wang, Eric K.↗

Durability of YSZ coated Ti2AlC in 1300°C high velocity burner rig tests

A thermal barrier coating system survived 500 h in cyclic burner rig tests at 1300°C, exceeding the life of all previous systems. An yttria stabilized zirconia (7YSZ) thermal barrier coating (TBC) was plasma sprayed on the oxidation resistant Ti2AlC MAX phase and tested in a jet fuel burner. No coating spallation or recession was observed, only a 2.4 mg/sq.cm mass gain due to typical cubic Al2O3 oxidation kinetics. The modest weight gain contrasted with large TBC spallation or oxide volatility losses that might occur under cyclic, high velocity (~100 m/s) burner conditions. The coating surface exhibited colonies of [111]flourite fiber-textured columns separated by craze crack patterns, but with no visible moisture attack. The thickness of the alumina scale under the YSZ face was >20 μm, more than twice that formed on TBC/superalloy systems at failure. TiO2 nodules, initially formed on the uncoated backside, were then removed as volatile hydroxides formed in high temperature, high velocity water vapor (~10%). Overall, the test indicated the exceptional stability of the YSZ/Ti2AlC system under turbine conditions, due in large part to good thermal expansion matching.

alumina, MAX phases, thermal barrier coatings (TBC↗

Analysis of Electro-static Assisted Air Dehumidification

The removal of water vapor from the air to reduce relative humidity is a well-known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. Also, the findings from the literature focused mainly on small flow rates on the order of one to two cfm. Electrically-enhanced condensation consists of the use of highly charged particles, preferably highly charged water droplets, that attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. An effect of the electric charge is the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation. Consequently, the equilibrium between evaporation and condensation is shifted towards condensation. Following the application of the modified Kelvin-Thomson theory, we developed a preliminary physics-based model to predict an effective size range of the charged droplets for optimal dehumidification. The range resulted in about 2 to 4 μm in diameter, under few simplifying assumptions. The effect of the size and the charge of the electrosprayed droplets on the overall dehumidification rate was briefly discussed. The use of electrosprays to produce small but highly charged droplets was broadly discussed in this paper. The cone-jet mode was identified as the most suitable electrospray operational mode, and it generated droplets of small size and high electrical charge. The cone-jet stability was also analyzed in detail. The preliminary data of the present work and the model results indicated that several electrospray heads were required to achieve a 5% dehumidification rate for airflow rates of about 5 cfm.

Morcelli, Stefano↗

Analysis of New Data of Electro-static Assisted Air Dehumidification Processes

The removal of water vapor from the air to reduce relative humidity is a well-known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. Also, the findings from the literature focused mainly on small flow rates on the order of one to two cfm. Electrically-enhanced condensation consists of the use of highly charged particles, preferably highly charged water droplets, that attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. An effect of the electric charge is the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation. Consequently, the equilibrium between evaporation and condensation is shifted towards condensation. Following the application of the modified Kelvin-Thomson theory, we developed a preliminary physics-based model to predict an effective size range of the charged droplets for optimal dehumidification. The range resulted in about 2 to 4 m in diameter, under few simplifying assumptions. The effect of the size and the charge of the electrosprayed droplets on the overall dehumidification rate was briefly discussed. The use of electrosprays to produce small but highly charged droplets was broadly discussed in this paper. The cone-jet mode was identified as the most suitable electrospray operational mode, and it generated droplets of small size and high electrical charge. The cone-jet stability was also analyzed in detail. The preliminary data of the present work and the model results indicated that several electrospray heads were required to achieve a 5% dehumidification rate for airflow rates of about 5 cfm.

Morcelli, Stefano↗

CIRS-lite, a Fourier Transform Spectrometer for Low-Cost Planetary Missions

Passive spectroscopic remote sensing of planetary atmospheres and surfaces in the thermal infrared is a powerful tool for obtaining information about surface and atmospheric temperatures, composition, and dynamics (via the thermal wind equation). Due to its broad spectral coverage, the Fourier transform spectrometer (FTS) is particularly suited to the exploration and discovery of molecular species. NASA's Goddard Space Flight Center (GSFC) developed the CIRS (Composite Infrared Spectrometer) FTS for the NASA/ESA Cassini mission to the Saturnian system. CIRS observes Saturn, Titan, icy moons such as Enceladus, and the rings in thermal self-emission over the spectral range of 7 to 1000 ell11. CIRS has given us important new insights into stratospheric composition and jets on Jupiter and Saturn, the cryo-geyser and thermal stripes on Enceladus, and the winter polar vortex on Titan. CIRS has a mass of 43 kg, contrasted with the earlier GSFC FTS, pre-Voyager IRIS (14 kg). Future low-cost planetary missions will have very tight constraints on science payload mass, thus we must endeavor to return to IRIS-level mass while maintaining CIRS-level science capabilities ("do more with less"). CIRS-lite achieves this by pursuing: a) more sensitive infrared detectors (high Tc superconductor) to enable smaller optics. b) changed long wavelength limit from 1000 to 300 microns to reduce diffraction by smaller optics. c) CVD (chemical vapor deposition) diamond beam-splitter for broad spectral coverage. d) single FTS architecture instead of a dual FTS architecture. e) novel materials, such as single crystal silicon for the input telescope primary.

Brasunas, J.↗

Stratified charge rotary engine - Internal flow studies at the MSU engine research laboratory

High-speed visualization and laser Doppler velocimetry (LDV) systems consisting of a 40-watt copper vapor laser, mirrors, cylindrical lenses, a high speed camera, a synchronization timing system, and a particle generator were developed for the study of the fuel spray-air mixing flow characteristics within the combustion chamber of a motored rotary engine. The laser beam is focused down to a sheet approximately 1 mm thick, passing through the combustion chamber and illuminates smoke particles entrained in the intake air. The light scattered off the particles is recorded by a high speed rotating prism camera. Movies are made showing the air flow within the combustion chamber. The results of a movie showing the development of a high-speed (100 Hz) high-pressure (68.94 MPa, 10,000 psi) fuel jet are also discussed. The visualization system is synchronized so that a pulse generated by the camera triggers the laser's thyratron.

Hamady, F.↗

Development of Hydroxyl Tagging Velocimetry for Low Velocity Flows

Hydroxyl tagging velocimetry (HTV) is a molecular tagging technique that relies on the photo-dissociation of water vapor into OH radicals and their subsequent tracking using laser induced fluorescence. Velocities are then obtained from time-of-flight calculations. At ambient temperature in air, the OH species lifetime is relatively short (<50 μs), making it suited for high speed flows. Lifetime and radicals formation increases with temperature, which allows HTV to also probe low-velocity, high-temperature flows or reacting flows such as flames. The present work aims at extending the domain of applicability of HTV, particularly towards low-speed (<10 m/s) and moderate (<500 K) temperature flows. Results are compared to particle image velocimetry (PIV) measurements recorded in identical conditions. Single shot and averaged velocity profiles are obtained in an air jet at room temperature. By modestly raising the temperature (100-200 degC) the OH production increases, resulting in an improvement of the signal-to-noise ratio (SNR). Use of nitrogen - a non-reactive gas with minimal collisional quenching - extends the OH species lifetime (to over 500 μs), which allows probing of slower flows or, alternately, increases the measurement precision at the expense of spatial resolution. Instantaneous velocity profiles are resolved in a 100degC nitrogen jet (maximum jet-center velocity of 6.5 m/s) with an uncertainty down to 0.10 m/s (1.5%) at 68% confidence level. MTV measurements are compared with particle image velocimetry and show agreement within 2%.

Andre, Matthieu A.↗

Mechanisms for the Intraseasonal Variability of Tropospheric Ozone over the Indian Ocean during the Winter Monsoon

We synthesize daily sonde (vertical) information and daily satellite (horizontal) information to provide an empirical description of ozone origins over the northern Indian Ocean during the INDOEX (Indian Ocean Experiment) field campaign (February-March 1999). This area is shown to be a significant portion of the "high-ozone tropics". East-west O3 features and their flow are identified, and ozone origins are compared to other tropical regions, using water vapor as a second tracer. In the study period, multiple processes contribute to O3 column enhancements, their importance varying strongly by latitude: (1) Low-altitude O3 pollution over the northern Indian Ocean mainly originates from the Indian subcontinent and is traceable to high emission areas. Convective activity south of Sri Lanka helps direct ozone outflow from the northern Indian subcontinent. (2) Middle tropospheric O3 maxima over the northern Indian Ocean originate from various sources, often transitioning within a few hours. Convective venting of Asian pollutants can add 20-30 ppbv to the middle troposphere at 5degN-10degN, alternating with stratospheric influence. (3) A number of cases suggest that strong mixing-in of stratospheric air along the subtropical jet raised tropospheric O3 in early March by approx.40-50 ppbv, especially poleward of approx. 10degN. (4) Influences of lightning and large-scale biomass burning were not strong during this period, in contrast to the situation in Africa and the South Atlantic or locally in Southeast Asia. This work illustrates successes and limitations in approaches to synthesizing disparate information on trace-gas distributions taken from satellite retrieval products and ozonesondes.

Chatfield, R. b.↗

Structure of Laminar Permanently Blue, Opposed-Jet Ethylene-Fueled Diffusion Flames

The structure and state relationships of laminar soot-free (permanently blue) ethylene-fueled diffusion flames at various strain rates were studied both experimentally and computationally using an opposed-jet configuration. Measurements of gas velocities, temperatures, and compositions were carried out along the stagnation stream line. Corresponding predictions of flame structure were obtained, based on numerical simulations using several contemporary reaction mechanisms for methane oxidation. Flame conditions studied included ethylene-fueled opposed-jet diffusion flames having stoichiometric mixture fractions of 0.7 with measurements involving strain rates of 60-240/s and predictions involving strain rates of 0-1140/s at normal temperature and pressure. It was found that measured major gas species concentrations and temperature distributions were in reasonably good agreement with predictions using mechanisms due to GRI-Mech and Peters and that effects of preferential diffusion significantly influence flame structure even when reactant mass diffusivities are similar. Oxygen leakage to fuel-rich conditions and carbon monoxide leakage to fuel-lean conditions both increased as strain rates increased. Furthermore, increased strain rates caused increased fuel concentrations near the flame sheet, decreased peak gas temperatures, and decreased concentrations of carbon dioxide and water vapor throughout the flames. State relationships for major gas species and gas temperatures were found to exist over a broad range of strain rates, providing potential for significant computational simplifications for modeling purposes in some instances.

Lin, K.-C.↗