Search NASA⌕ Search

SEARCH · Search NASA

Results for “VIBRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Radiative relaxation of molecular vibration of the nitric oxide molecule as a possible source of the infrared Shuttle glow

A model calculation to predict infrared Shuttle flow due to the radiative relaxation of vibration of the NO molecule is presented. Space Shuttles hit atmospheric NO molecules at a very high speed and excite vibrational and rotational motions up to the temperature of 54,000 K. With the electric dipole radiation of delta v = 1, 2, 3, and particularly 4 (v is the vibrational quantum number), the excited NO molecules emit infrared radiation before they collide with other molecules. The total radiation power is estimated to be 170 A micro-W, where A is the cross-section area of the Shuttle in sq m if no adsorption of the NO molecule takes place on the Shuttle surface. The intensity of each infrared line is calculated as a function of time, including all vibrational states up to v = 35.

Mizushima, M.↗

Shuttle glow emissions due to radiative relaxation of highly vibrationally excited NO molecules produced by surface reflection

A new mechanism is proposed for the Space Shuttle glow, which is due to the radiative relaxation of ambient nitric-oxide molecules that are excited to very high vibrational levels by collisions with the Shuttle surface. Many of the particles colliding with the Shuttle surface at a very high speed (about 8 km/sec) would bounce off, exciting vibrational and rotational motions of molecules up to the level of vibrational quantum number v not greater than 35. Radiative transfer from these high levels should cause emissions in the spectrum range from infrared (IR) to visible red depending upon the transition paths. A perturbation method is used to calculate the transition probability and the emission intensity for the transitions of Delta-v not greater than 4. The result indicates that the Delta-v not greater than 4 transitions from high vibrational levels dominates the other transitions; the Delta-v = 4 transitions generally occur at the IR range.

Shimazaki, T.↗

Equations for the vibration of a slewing flexible spacecraft

The derivation of the equations describing the vibration of a flexible spacecraft is presented in the context of a perturbation method permitting a maneuver strategy independent of the vibration control. A straightforward open-loop minimum-time rotational maneuver strategy is developed for the spacecraft regarded as a rigid body. Actuator dynamics are considered in the formulation. A maneuver force distribution is developed which excites the least amount of elastic deformation of the flexible parts of the spacecraft. An efficient technique for simulating structural vibrations during a maneuver is presented. Numerical results demonstrate the maneuver strategy and highlight the vibration caused by rotational maneuvers.

Quinn, R. D.↗

Six-Degree-of-Freedom Vibration Suppressor

New system, total-rotor-isolation system (TRIS) employs liquid-inertia vibration-eliminator (LIVE) units, designed to isolate all six degrees of freedom of aircraft-fuselage dynamic response from continuously changing airloads developed by rotor. Vibration suppressor uses liquid mercury to damp vibrations. Results of flight tests indicated at least 95-percent reduction in vibration levels from rotor hub to pilot's seat.

Halwes, Dennis R.↗

Effect of vibration amplitude on vapor cavitation in journal bearings

Computational movies were used to analyze the formation and collapse of vapor cavitation bubbles in a submerged journal bearing. The effect of vibration amplitude on vapor cavitation was studied for a journal undergoing circular whirl. The boundary conditions were implemented using Elrod's algorithm, which conserves mass flow through the cavitation bubble as well as through the oil-film region of the bearing. The vibration amplitudes for the different cases studied resulted in maximum eccentricity ratios ranging from 0.4 to 0.9. The minimum eccentricity ratio reached in each case was 0.1. For the least vibration amplitude studied in which the eccentricity ratio varied between 0.1 and 0.4, no vapor cavitation occurred. The largest vibration amplitude (i.e., eccentricity ratios of 0.1 to 0.9) resulted in vapor cavitation present 76 percent of one complete orbit.

Brewe, D. E.↗

Emitted vibration measurement device and method

This invention is directed to a method and apparatus for measuring emitted vibrational forces produced by a reaction wheel assembly due to imbalances, misalignment, bearing defects and the like. The apparatus includes a low mass carriage supported on a large mass base. The carriage is in the form of an octagonal frame having an opening which is adapted for receiving the reaction wheel assembly supported thereon by means of a mounting ring. The carriage is supported on the base by means of air bearings which support the carriage in a generally frictionless manner when supplied with compressed air from a source. A plurality of carriage brackets and a plurality of base blocks provided for physical coupling of the base and carriage. The sensing axes of the load cells are arranged generally parallel to the base and connected between the base and carriage such that all of the vibrational forces emitted by the reaction wheel assembly are effectively transmitted through the sensing axes of the load cells. In this manner, a highly reliable and accurate measurment of the vibrational forces of the reaction wheel assembly can be had. The output signals from the load cells are subjected to a dynamical analyzer which analyzes and identifies the rotor and spin bearing components which are causing the vibrational forces.

Gisler, G. L.↗

Optimum vibration control of flexible beams by piezo-electric actuators

The utilization of piezoelectric actuators in controlling the structural vibrations of flexible beams is examined. A Modified Independent Modal Space Control (MIMSC) method is devised to enable the selection of the optimal location, control gains and excitation voltage of the piezoelectric actuators in a way that would minimize the amplitudes of vibrations of beams to which these actuators are bonded, as well as the input control energy necessary to suppress these vibrations. The developed method accounts for the effects that the piezoelectric actuators have on changing the elastic and inertial properties of the flexible beams. Numerical examples are presented to illustrate the application of the developed MIMSC method in minimizing the structural vibrations of beams of different materials when subjected to different loading and end conditions using ceramic or polymeric piezoelectric actuators. The obtained results emphasize the importance of the devised method in designing more realistic active control systems for flexible beams, in particular, and large flexible structures in general.

Baz, A.↗

Vibration characteristics of OH-58A helicopter main rotor transmission

Experimental vibration tests covering a range of torque and speed conditions were performed on the OH-58A helicopter main rotor transmission at the NASA Lewis Research Center. Signals from accelerometers located on the transmission housing were analyzed by using Fourier spectra, power spectral density functions, and averaging techniques. Most peaks of the Fourier spectra occurred at the spiral bevel and planetary gear mesh harmonics. The highest level of vibration occurred at the spiral bevel meshing frequency. Transmission speed and vibration measurement location had a significant effect on measured vibration; transmission torque and measurement direction had a small effect.

Lewicki, David G.↗

Analytical and experimental studies of flow-induced vibration of SSME components

Components of the Space Shuttle Main Engines (SSMEs) are subjected to a severe environment that includes high-temperature, high-velocity flows. Such flows represent a source of energy that can induce and sustain large-amplitude vibratory stresses and/or result in fluidelastic instabilities. Three components are already known to have experienced failures in evaluation tests as a result of flow-induced structural motion. These components include the liquid-oxygen (LOX) posts, the fuel turbine bellows shield, and the internal inlet tee splitter vane. Researchers considered the dynamic behavior of each of these components with varying degrees of effort: (1) a theoretical and experimental study of LOX post vibration excited by a fluid flow; (2) an assessment of the internal inlet tee splitter vane vibration (referred to as the 4000-Hz vibration problem); and (3) a preliminary consideration of the bellows shield problem. Efforts to resolve flow-induced vibration problems associated with the SSMEs are summarized.

Chen, S. S.↗

Computer animation of modal and transient vibrations

An interactive computer graphics processor is described that is capable of generating input to animate modal and transient vibrations of finite element models on an interactive graphics system. The results from NASTRAN can be postprocessed such that a three dimensional wire-frame picture, in perspective, of the finite element mesh is drawn on the graphics display. Modal vibrations of any mode shape or transient motions over any range of steps can be animated. The finite element mesh can be color-coded by any component of displacement. Viewing parameters and the rate of vibration of the finite element model can be interactively updated while the structure is vibrating.

Lipman, Robert R.↗

Vibration suppression of planar truss structures utilizing uniform damping control

A variety of methods has been devised for vibrational control of a structure using both passive and active controls. Presented in this paper is a relatively new method for vibration suppression, uniform damping control. This method consists of implementing a control law which tends to dampen each vibrational mode of the structure at the same desirable exponential rate. The unique aspects of this method are that the control law is not explicitly dependent on the structural stiffness, the control forces are directly proportional to the distribution of the structural mass, and the control law is natural and decentralized. The control law was applied to a flexible planar truss structure and the various aspects of implementation of the control law examined are: actuator/sensor number, placement, and the impact of the actuator/sensor number and placement on the necessary control 'power' requirements such as peak power loads, total power requirements, etc. Also examined are the effects of using a limited number of active members in terms of the vibrational performance when compared with the 'ideal' distributed control law.

Andersen, G. C.↗

Low frequency vibrational stirring - A new method for rapidly mixing solutions and melts during growth

A new method for rapidly stirring liquids has been developed which may be useful in crystal growth applications. The method involves the introduction of orthogonally coupled low frequency vibrations to fluids contained in cylindrical crucibles. A mathematical model has been developed to describe the influence of this vibrational stirring method on fluid flow. The optimum sloshing frequencies calculated for a specific system geometry were very close to those observed experimentally. A systematic study of the fluid flow induced by the vibrational motion was carried out at room temperature using aqueous solutions containing glycerine. Preliminary experiments were carried out to study the effect of vibrational stirring on interface shape and position during the Bridgman growth of CsCdCl3, a model system.

Liu, W.-S.↗

Measuring Vibrations With Nonvibration Sensors

Information about vibrations of structure and/or of nonvibration sensor attached to structure extracted from output of sensor. Sensor operated in usual way except, output fed to power-spectral-density analyzer. Vibrational components easily distinguishable in analyzer output because they have frequencies much higher than those of more-slowly-varying temperature, pressure, or other normally desired components. Spectral-analysis technique applied successfully to high-frequency resistance changes in output of platinum-wire resistance thermometer: vibrational peaks in resistance frequency spectrum confirmed by spectrum from accelerometer. Technique also showed predicted 17-kHz vibrational resonance in strain-guage-supporting beam in pressure sensor.

Hill, Arthur J.↗

Simplified Analysis Of Vehicle/Payload Vibrations

Simplified mathematical model of coupled vibrations of vehicle and its payloads used in stability analysis for control purposes. Multiple-payload stability criterion extension of single-payload criterion based on measurements and detailed calculations of fundamental vibrational modes of vehicle and payload. Represented in simplified form by coupled masses and springs vibrating in one dimension, each spring having stiffness that gives rise to previously determined fundamental vibrational frequency associated mass in absence of coupling with other mass. Developed to avoid complexity and cost of full vibrations/stability calculations for each different combination of Space Shuttle payloads, simplified analysis technique also useful in assessing stability in loaded airplanes, ships, trucks, cranes, and conveyor systems.

Yu, Reginald R. J.↗

Passive damping concepts for free and forced member and grillage vibration

The performance of potential passive damping concepts is investigted for a long tubular aluminum alloy member, and a two-bar grillage structure. The members are restrained partially at the ends and are of the type being considered by NASA for possible use in the construction of a future space station. Four different passive damping concepts are studied and include nylon brush, wool swab, copper brush, and silly putty in chamber dampers. Both free and forced vibration tests are conducted. It is found that the silly putty in chamber damper concept provides considerably greater passive damping as compared to that of the other three concepts. For the grillage natural vibration, a five wool swab damper configuration provides greater damping than the five silly putty dampers in chamber configuration. Due to the constrained motion imposed by the vibrator used in the tests, the effectiveness of the passive dampers could not be adequately evaluated for the individual member. However, it is found that for the grillage under forced vibration, the five silly putty dampers in chamber damper configuration provides very effective passive damping although only at and around the resonant frequency. At resonance, these dampers provide a 51 percent reduction in the dynamic magnification factor for this case.

Razzaq, Zia↗

Maneuvering and vibration control of flexible spacecraft

This paper is concerned with the problem of slewing a large structure in space and suppressing any vibration at the same time. The structure is assumed to undergo large rigid-body motions and small elastic deformations. A perturbation method permits a maneuver strategy independent of the vibration control. Optimal control and pole placement techniques, formulated to include first-order actuator dynamics, are used to suppress the vibration during maneuver. The theory is illustrated by simultaneous maneuvering and vibration control of the Spacecraft Control Laboratory Experiment (SCOLE) model in a space environment.

Meirovitch, L.↗

Active control of transient rotordynamic vibration by optimal control methods

Although considerable effort has been put into the study of steady state vibration control, there are few methods applicable to transient vibration control of rotorbearing systems. In this paper optimal control theory has been adopted to minimize rotor vibration due to sudden imbalance, e.g., blade loss. The system gain matrix is obtained by choosing the weighting matrices and solving the Riccati equation. Control forces are applied to the system via a feedback loop. A seven mass rotor system is simulated for illustration. A relationship between the number of sensors and the number of modes used in the optimal control model is investigated. Comparisons of responses are made for various configurations of modes, sensors, and actuators. Furthermore, spillover effect is examined by comparing results from collocated and noncollocated sensor configurations. Results show that shaft vibration is significantly attenuated in the closed loop system.

Palazzolo, A. B.↗

Damper Of Small Vibrations

Vibration damper has no rubbing parts. Thus eliminates even very small static frictional forces and therefore responds to and damps extremely low levels of vibration. Damper dissipates vibration by motion of piston in volume of silicone oil. Coaxial rigid shaft holds upper and lower bellows at constant length while piston vibrates up and down. Although volumes of upper and lower bellows change continually, total volume of bellows assembly stays same.

Davis, L. P.↗