Search NASA⌕ Search

SEARCH · Search NASA

Results for “VISUAL SIGNAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Spaceborne astronomy with electro-optical image sensors

The Space Telescope, planned for orbiting in the early 1980s, is described, with emphasis on its electro-optical image sensing capability. Relative advantages of image tubes and solid state arrays as image detectors are summarized; image tube technology is well characterized, but preference may be given to a more versatile tandem solid state array consisting of one module with high silicon response covering most of the spectrum, and a second intensified array with ultraviolet sensitivity and low noise readout. The classical 'photoelectron noise limit' calculation is reviewed, and a detailed calculation of sensitivity limits adaptable to analysis of image tube or solid state array detectors is also given. In particular, characteristics of a filter to optimize the signal to noise ratio is determined. Typical sensitivity calculations for an image tube detector show that with an exposure of one orbital night (approximately 2000 seconds), 10% photometry may be done to a low limit of visual magnitude.

Bradley, W. C.↗

Application of optical methods to the study of jet noise and turbulence

Optical methods are generally applied in fluid mechanics for either visualization or measurement. The use of a laser anemometer to study flow velocity in a jet and its relaton to the sound radiated is described. The same acoustic emission phenomenon is also measued by combining the signals from four Schlieren systems with that from an interferometer. The use of an optical Fourier transformation approach with real time analysis to determine the spatio-temporal structure of a field of mass volume such as a waveguide or free jet is also examined.

Sava, P. G.↗

Networks for image acquisition, processing and display

The human visual system comprises layers of networks which sample, process, and code images. Understanding these networks is a valuable means of understanding human vision and of designing autonomous vision systems based on network processing. Ames Research Center has an ongoing program to develop computational models of such networks. The models predict human performance in detection of targets and in discrimination of displayed information. In addition, the models are artificial vision systems sharing properties with biological vision that has been tuned by evolution for high performance. Properties include variable density sampling, noise immunity, multi-resolution coding, and fault-tolerance. The research stresses analysis of noise in visual networks, including sampling, photon, and processing unit noises. Specific accomplishments include: models of sampling array growth with variable density and irregularity comparable to that of the retinal cone mosaic; noise models of networks with signal-dependent and independent noise; models of network connection development for preserving spatial registration and interpolation; multi-resolution encoding models based on hexagonal arrays (HOP transform); and mathematical procedures for simplifying analysis of large networks.

Ahumada, Albert J., Jr.↗

Flexible substrata for the detection of cellular traction forces

By modulating adhesion signaling and cytoskeletal organization, mechanical forces play an important role in various cellular functions, from propelling cell migration to mediating communication between cells. Recent developments have resulted in several new approaches for the detection, analysis and visualization of mechanical forces generated by cultured cells. Combining these methods with other approaches, such as green-fluorescent protein (GFP) imaging and gene manipulation, proves to be particularly powerful for analyzing the interplay between extracellular physical forces and intracellular chemical events.

Review, Tutorial↗

The human oculomotor response to simultaneous visual and physical movements at two different frequencies

In order to investigate interactions in the visual and vestibular systems' oculomotor response to linear movement, we developed a two-frequency stimulation technique. Thirteen subjects lay on their backs and were oscillated sinusoidally along their z-axes at between 0.31 and 0.81 Hz. During the oscillation subjects viewed a large, high-contrast, visual pattern oscillating in the same direction as the physical motion but at a different, non-harmonically related frequency. The evoked eye movements were measured by video-oculography and spectrally analysed. We found significant signal level at the sum and difference frequencies as well as at other frequencies not present in either stimulus. The emergence of new frequencies indicates non-linear processing consistent with an agreement-detector system that have previously proposed.

NASA Discipline Neuroscience↗

Flight Deck Interval Management Avionics: Eye-Tracking Analysis

Interval Management (IM) is one NexGen method for achieving airspace efficiencies. In order to initiate IM procedures, Air Traffic Control provides an IM clearance to the IM aircraft's pilots that indicates an intended spacing from another aircraft (the target to follow - or TTF) and the point at which this should be achieved. Pilots enter the clearance in the flight deck IM (FIM) system; and once the TTF's Automatic Dependent Surveillance-Broadcast signal is available, the FIM algorithm generates target speeds to meet that IM goal. This study examined four Avionics Conditions (defined by the instrumentation and location presenting FIM information) and three Notification Methods (defined by the visual and aural alerts that notified pilots to IM-related events). Current commercial pilots flew descents into Dallas/Fort-Worth in a high-fidelity commercial flight deck simulation environment with realistic traffic and communications. All 12 crews experienced each Avionics Condition, where order was counterbalanced over crews. Each crew used only one of the three Notification Methods. This paper presents results from eye tracking data collected from both pilots, including: normalized number of samples falling within FIM displays, normalized heads-up time, noticing time, dwell time on first FIM display look after a new speed, a workload-related metric, and a measure comparing the scan paths of pilot flying and pilot monitoring; and discusses these in the context of other objective (vertical and speed profile deviations, response time to dial in commanded speeds, out-of-speed-conformance and reminder indications) and subjective measures (workload, situation awareness, usability, and operational acceptability).

Latorella, Kara↗

Ultraintense, ultrashort pulse X-ray scattering in small molecules

In this work, we examine X-ray scattering from an isolated organic molecule from the linear to nonlinear absorptive regime. In the nonlinear regime, we explore the importance of both the coherent and incoherent channels and observe the onset of nonlinear behavior as a function of pulse duration and energy. In the linear regime, we test the sensitivity of the scattering signal to molecular bonding and electronic correlation via calculations using the independent atom model (IAM), Hartree–Fock (HF) and density functional theory (DFT). Finally, we describe how coherent X-ray scattering can be used to directly visualize femtosecond charge transfer and dissociation within a single molecule undergoing X-ray multiphoton absorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fast Semi-automated Filtration Method for Non-targeted LC-QTOF Data of Aged Nitroplasticizer Samples

A full dataset of aged nitroplasticizer (NP) is composed of more than 2000 unique mass-to-charges (m/z) when combining the non-targeted data obtained from both positive and negative electrospray ionization modes in time-of-flight mass spectrometry. Therefore, manual processing of these data often takes days, weeks, or even months to scrutinize for mechanistic insights. To effectively extract meaningful signals that represent vital degradation intermediates in the early NP degradation mechanism, a semi-automated postprocessing workflow for data filtering, tailored to the aging experiment of NP, has been developed. The automated portion of this workflow is written in a Python code (using pandas, numpy, and matplotlib libraries), which removes more than 65% of potential false signals within seconds via four threshold-based adjustable filters: signal sensitivity, coefficient of variation, number of measurements, and retention time variability. As for the manual portion, a pattern-based inspection method is employed to reduce another 23% or more false positives, which greatly simplifies data visualization and results in less than 3% of potential candidate m/z needing in-depth data interpretation. As a positive control, known compounds are verified. Using this semi-automated data reduction method, the amount of time required is reduced to a matter of hours for data filtering in the non-targeted datasets of aged NP, which saves more time and effort for compound identification.

36 MATERIALS SCIENCE↗

Vigilance and task load - In search of the inverted U

The 'Inverted-U Hypothesis' states that for a given task, there is an optimal level of workload or demand that yields the highest level of performance. A departure in either direction will result in a monotonically lower performance level, hence an inverted-U-shaped relationship between task demand and quality of performance. Most studies to date have failed to demonstrate the left-hand branch of the curve, that is, the regime in which performance presumably rises as load increases. The purpose of this study was to explore whether low-level additional demand on the monitor would result in improved performance. Four groups of subjects performed a visual monitoring task for 48 min, then two of the four groups were given additional tasks, and a third had potentially distracting information on its display. Results indicated that the two groups with additional demand detected more signals than did the control group or the control-plus-distraction group. There were no significant differences in false alarms.

Wiener, E. L.↗

Nondestructive Detection of Cracks in Ceramics Using Vicinal Illumination

Cracks and other defects in ceramic materials can be difficult or impossible to examine and photograph due to the extreme lack of contrast. A method for inspecting translucent ceramics using scattered light, also known as vicinal illumination, will be described. This method has been known in the ceramics industry for quite some time, but is not well known in the testing and failure analysis community. Electronics applications include substrates, packages, multilayer capacitors, and thin film resistors. Ceramic materials are used in electronic applications as microcircuit packages and substrates which carry signals and power between microcircuits. Fine cracks in ceramic materials can result in mechanical failures, electrical failures, and loss of hermeticity. Often, fine cracks are difficult or impossible to detect using standard nondestructive inspection techniques such as visual inspection, ultrasonic inspection, or vapor crack detection. Dye penetrant inspection is usually effective, but contaminates the part, which is unacceptable for space flight hardware. One effective nondestructive inspection method of detecting cracks involves examining the way in which light scatters through the ceramic material when viewed with a standard bright field reflected light microscope. This method, termed vicinal illumination, has been used for detecting cracks during failure analyses of several part types, and screening of space flight hardware. The technique has proven effective on several different types of ceramic materials as well. A related method for use with dark field equipment has also been used to successfully locate otherwise invisible cracks.

Hull, Scott M.↗

Comparisons Between NO PLIF Imaging and CFD Simulations of Mixing Flowfields for High-Speed Fuel Injectors

The current work compares experimentally and computationally obtained nitric oxide (NO) planar laser induced fluorescence (PLIF) images of the mixing flowfields for three types of high-speed fuel injectors: a strut, a ramp, and a rectangular flushwall. These injection devices, which exhibited promising mixing performance at lower flight Mach numbers, are currently being studied as a part of the Enhanced Injection and Mixing Project (EIMP) at the NASA Langley Research Center. The EIMP aims to investigate scramjet fuel injection and mixing physics, and improve the understanding of underlying physical processes relevant to flight Mach numbers greater than eight. In the experiments, conducted in the NASA Langley Arc-Heated Scramjet Test Facility (AHSTF), the injectors are placed downstream of a Mach 6 facility nozzle, which simulates the high Mach number air flow at the entrance of a scramjet combustor. Helium is used as an inert substitute for hydrogen fuel. Both schlieren and PLIF techniques are applied to obtain mixing flowfield flow visualizations. The experimental PLIF is obtained by using a UV laser sheet to interrogate a plane of the flow by exciting fluorescence from the NO molecules, which are present in the AHSTF air. Consequently, the absence of signal in the resulting PLIF images is an indication of pure helium (fuel). The computational PLIF is obtained by applying a fluorescence model for NO to the results of the Reynolds-averaged simulations (RAS) of the mixing flow field carried out using the VULCAN-CFD solver. This approach is required because the PLIF signal is a nonlinear function of not only NO concentration, but also pressure, temperature, and the flow velocity. This complexity allows additional flow features to be identified and compared with those obtained from the computational fluid dynamics (CFD) simulations, however, such comparisons are only semiquantitative. Three-dimensional image reconstruction, similar to that used in magnetic resonance imaging, is also used to obtain images in the streamwise and spanwise planes from select cross-stream PLIF plane data. Synthetic schlieren is also computed from the RAS data. Good agreement between the experimental and computational results provides increased confidence in the CFD simulations for investigations of injector performance.

Drozda, Tomasz G.↗

Virtual and Augmented Reality Applications in Science and Engineering

The articles in this special section focus on virtual and augmented reality applications in science and engineering. There has been an explosive growth in visually augmenting the spaces around us by creating environments where visual, aural, and kinesthetic immersive experiences afforded by virtual and augmented reality (AR) powerfully engage us in a way no other medium can. Virtual reality (VR) recreates the sensory world around us entirely through computer-generated signals of sight, sound, touch (and in some cases smell and taste). AR overlays the computer-generated sensory signals on the real world allowing the user to experience a rich juxtaposition of the virtual and the real worlds simultaneously. Together, these technologies are transforming the way people from all walks of life—scientists, engineers, educators, industrial workers, health care professionals, artists, and everyday people— see and use the information that matters most to them, in an intuitive embodied way. Just as mobile technology has revolutionized how we communicate with each other and with our digital worlds, ubiquitous VR and AR will fundamentally alter how our society creates, inspires, engages, and learns from the information-rich and enriched cyberspaces around us. While affordable consumer- quality VR and AR hardware is becoming available, significant work is needed to adopt VR and AR for important and difficult scientific and societal applications.

Virtual Reality, Augmented Reality↗

Comparisons Between NO PLIF Imaging and CFD Simulations of Mixing Flowfields for High-Speed Fuel Injectors

The current work compares experimentally and computationally obtained nitric oxide (NO) planar laser-induced fluorescence (PLIF) images of the mixing flowfields for three types of high-speed fuel injectors: a strut, a ramp, and a rectangular flushwall. These injection devices, which exhibited promising mixing performance at lower flight Mach numbers, are currently being studied as a part of the Enhanced Injection and Mixing Project (EIMP) at the NASA Langley Research Center. The EIMP aims to investigate scramjet fuel injection and mixing physics, and improve the understanding of underlying physical processes relevant to flight Mach numbers greater than eight. In the experiments conducted in the NASA Langley Arc-Heated Scramjet Test Facility (AHSTF), the injectors are placed downstream of a Mach 6 facility nozzle, which simulates the high Mach number air flow at the entrance of a scramjet combustor. Helium is used as an inert substitute for hydrogen fuel. Both schlieren and PLIF techniques are applied to obtain mixing flowfield flow visualizations. The experimental PLIF is obtained by using a UV laser sheet to interrogate a plane of the flow by exciting fluorescence from the NO molecules that are present in the AHSTF air. Consequently, the absence of signal in the resulting PLIF images is an indication of pure helium (fuel). The computational PLIF is obtained by applying a fluorescence model for NO to the results of the Reynolds-averaged simulations (RAS) of the mixing flowfield carried out using the VULCAN-CFD solver. This approach is required because the PLIF signal is a nonlinear function of not only NO concentration, but also pressure, temperature, and the flow velocity. This complexity allows additional flow features to be identified and compared with those obtained from the computational fluid dynamics (CFD) simulations, however, such comparisons are only semiquantitative. Three-dimensional image reconstruction, similar to that used in magnetic resonance imaging, is also used to obtain images in the streamwise and spanwise planes from select cross-stream PLIF plane data. Synthetic schlieren is also computed from the RAS data. Good agreement between the experimental and computational results provides increased confidence in the CFD simulations for investigations of injector performance.

PLIF↗

Comparisons Between NO PLIF Imaging and CFD Simulations of Mixing Flowfields for High-Speed Fuel Injectors

The current work compares experimentally and computationally obtained nitric oxide (NO) planar laser-induced fluorescence (PLIF) images of the mixing flowfields for three types of high-speed fuel injectors: a strut, a ramp, and a rectangular flushwall. These injection devices, which exhibited promising mixing performance at lower flight Mach numbers, are currently being studied as a part of the Enhanced Injection and Mixing Project (EIMP) at the NASA Langley Research Center. The EIMP aims to investigate scramjet fuel injection and mixing physics, and improve the understanding of underlying physical processes relevant to flight Mach numbers greater than eight. In the experiments conducted in the NASA Langley Arc-Heated Scramjet Test Facility (AHSTF), the injectors are placed downstream of a Mach 6 facility nozzle, which simulates the high Mach number air flow at the entrance of a scramjet combustor. Helium is used as an inert substitute for hydrogen fuel. Both schlieren and PLIF techniques are applied to obtain mixing flowfield flow visualizations. The experimental PLIF is obtained by using a UV laser sheet to interrogate a plane of the flow by exciting fluorescence from the NO molecules that are present in the AHSTF air. Consequently, the absence of signal in the resulting PLIF images is an indication of pure helium (fuel). The computational PLIF is obtained by applying a fluorescence model for NO to the results of the Reynolds-averaged simulations (RAS) of the mixing flowfield carried out using the VULCAN-CFD solver. This approach is required because the PLIF signal is a nonlinear function of not only NO concentration, but also pressure, temperature, and the flow velocity. This complexity allows additional flow features to be identified and compared with those obtained from the computational fluid dynamics (CFD) simulations, however, such comparisons are only semiquantitative. Three-dimensional image reconstruction, similar to that used in magnetic resonance imaging, is also used to obtain images in the streamwise and spanwise planes from select cross-stream PLIF plane data. Synthetic schlieren is also computed from the RAS data. Good agreement between the experimental and computational results provides increased confidence in the CFD simulations for investigations of injector performance.

PLIF↗

XRF Characterization of MMOD Impact Damage

Introduction The Hypervelocity Impact Technology (HVIT) Group at the NASA Johnson Space Center (JSC) has performed over 150 post flight MMOD inspections on returned space-ex-posed hardware and collected over 1,600 samples. Determination of the impactor source typically requires an analysis of the projectile residue in the damage feature. At this time, about 20% of the samples have been processed. Types of Samples Samples in the HVIT group collection can be classified into two types. Indirect (non-destructive) samples are produced when a pliable material (e.g., adhesive tape or dental mold) is inserted into an impact feature. With this type of sampling technique, crater material and (hopefully) projectile residue material is embedded in the sample media and can detected using further chemical characterizing techniques. Direct (destructive) sampling involves the in-tact extraction of material from the spacecraft and is done in a manner that the entire impact feature can be excised intact. This technique provides the greatest chance of successfully determining impactor source due to the entirety of the projectile remnants being present within the collected sample. Updated Projectile Residue Detection Techniques Previous assessments of projectile provenance have involved the use of samples that are first mounted in epoxy, sectioned to expose the crater interior, imaged with a scanning electron microscope (SEM), then any observed impactor residue was then analyzed using an energy dispersive spectrometer (EDS). This technique, while proven, may be supplemented with other types of elemental analysis techniques that can observe major element chemistry, in order to improve throughput of sample analysis. The Astromaterials Research and Exploration Science (ARES) Division at JSC, for example, operates a Bruker M4 Tornado micro-X-Ray fluorescence (XRF) spectrometer, capable of creating elemental maps of areas around these small impact features in a couple of hours, with a spot size <20 μm. The potential advantage with this technique lies in sample preparation, as no polishing or conductive coatings are needed. Early trials attempted to deter-mine impactor composition by collecting spectra from intact samples by aiming the X-Rays directly into the impact feature, but the signal:noise ratio was too low for confident material identification. Sample preparation for XRF then relies on sectioning the samples parallel to the impactor trajectory in order to expose the largest area of subsurface damage possible, thus maximizing the signal from any small impactor remnants. Complementary to the use of XRF for sample analysis, ARES also houses a Nikon XTH 320 micro-X-Ray computed tomography (XCT). This instrument can be used to create 3D visualizations of impact damage for the determination of crater volumes and dimensions, as well as for the determination of the best place to section each sample for the subsequent XRF analysis.

J L Hyde↗

OH PLIF Visualization of a Premixed Ethylene-fueled Dual-Mode Scramjet Combustor

Hydroxyl radical (OH) planar induced laser fluorescence (PLIF) measurements have been performed in a small-scale scramjet combustor at the University of Virginia Aerospace Research Laboratory at nominal simulated Mach 5 enthalpy. OH lines were carefully chosen to have fluorescent signal that is independent of pressure and temperature but linear with mole fraction. The OH PLIF signal was imaged in planes orthogonal to and parallel to the freestream flow at different equivalence ratios. Flameout limits were tested and identified. Instantaneous planar images were recorded and analyzed to compare the results with width increased dual-pump enhanced coherent anti-Stokes Raman spectroscopy (WIDECARS) measurements in the same facility and large eddy simulation/Reynolds average Navier-Stokes (LES/RANS) numerical simulation. The flame angle was found to be approximately 10 degrees for several different conditions, which is in agreement with numerical predictions and measurements using WIDECARS. Finally, a comparison between NO PLIF non-combustion cases and OH PLIF combustion cases is provided: the comparison reveals that the dominant effect of flame propagation is freestream turbulence rather than heat release and concentration gradients.

Cantu, Luca M. L.↗

Giant spin-selective bandgap renormalization in CsPbBr 3 colloidal nanocrystals

The spin-dependence of the strongly correlated phenomena and many-body interactions play an important role in quantum information science. In particular, it is quite interesting but unclear how the spin degree of freedom ramifies the bandgap renormalization, one of the fundamental many-body phenomena. We report the first room-temperature observation of giant spin-selective bandgap renormalization (SS-BGR) in CsPbBr 3 colloidal nanocrystals using time-resolved circularly polarized femtosecond pump-probe spectroscopy. The SS-BGR results from many-body interactions among carriers with the same spin that renormalize their joint density of states by 57+/- 1 meV, visualized here as photoinduced absorption (PIA) below band-edge transition energy when the pump and probe are co-polarized. The hallmark result of spectrally resolved SS-BGR is in stark contrast to the usually submerged signal in II-VI and III-V semiconductors and is 3 orders of magnitude larger than that observed in Ge/SiGe quantum wells, highlighting the unique and beneficial band structure of the metal-halide semiconductors. We propose that the PIA, due to SS-BGR, can be used to describe the spin-polarization and spin-relaxation dynamics. The experimental and theoretical findings open up new possibilities for optical manipulation of spin degrees of freedom and their many-body interactions in metal-halide perovskite nanocrystals for potential room-temperature applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Motion effects on an IFR hovering task: Analytical predictions and experimental results

An analytical pilot model incorporating the effects of motion cues and display scanning and sampling is tested by comparing predictions against experimental results on a moving base simulator. The simulated task is that of precision hovering of a VTOL having varying amounts of rate damping, and using separated instrument displays. Motion cue effects are investigated by running the experiment under fixed and moving base conditions, the latter in two modes; full motion, and angular motion only. Display scanning behavior is measured on some of the runs. The results of the program show that performance is best with angular motion only, most probably because a g-vector tilt cue is available to the pilot in this motion condition. This provides an attitude indication even when not visually fixating the attitude display. Vestibular threshold effects are also present in the results because of the display scaling used to permit hovering position control within the motion simulator limits; no washouts are used in the simulator drive signals. The IFR nature of the task results in large decrements in pilot opinion and performance relative to VFR conditions because of the scanning workload. Measurements of scanning behavior are sensitive to motion conditions and show more attention to attitude control under fixed base conditions.

Ringland, R. F.↗