Search NASA⌕ Search

SEARCH · Search NASA

Results for “VOLTAGE AMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A Simulation of the Fermilab Main Injector Cavities

The Fermilab Main Injector accelerating cavities have sparking issues when they are run at voltages higher than those required by the PIP-II project. This is a problem Fermilab is working on as planning begins for the next upgrade to the accelerator complex. One of the methods being used to address the issue is the development of a CST Microwave Studio simulation to accurately model the PIP-II dual power amplifier cavities and identify which part(s) of the cavity is causing sparking to develop. The model will also be used to determine if changes to the cavity geometry may allow the cavity to be used at higher voltages before sparking occurs

Stevenson, Susanna M. [Fermilab] (ORCID:0009000891↗

Modulation linearization of a frequency-modulated voltage controlled oscillator, part 3

An analysis is presented for the voltage versus frequency characteristics of a varactor modulated VHF voltage controlled oscillator in which the frequency deviation is linearized by using the nonlinear characteristics of a field effect transistor as a signal amplifier. The equations developed are used to calculate the oscillator output frequency in terms of pertinent circuit parameters. It is shown that the nonlinearity exponent of the FET has a pronounced influence on frequency deviation linearity, whereas the junction exponent of the varactor controls total frequency deviation for a given input signal. A design example for a 250 MHz frequency modulated oscillator is presented.

Honnell, M. A.↗

Controlled freezing of biological samples

Apparatus consists of thermocouple connected to semiconductor reference junction. Junction is connected to amplifier that boosts signal by 1,000. High-level signal is displayed on recorder and fed into second amplifier where it is compared with signal from potentiometer of programmed dc reference in bag-temperature programer. Difference in signals indicates output voltage. Remaining circuitry provides zero-phase, time-proportion control of heaters such that heater power is directly proportional to error signal.

Cygnarowicz, T. A.↗

Development of an apparatus for obtaining molecular beams in the energy range from 2 to 200 eV

The formation and detection of molecular beams obtained by charge exchange from a low-energy ion source is discussed. Dispersion in energy of the ion source was measured and problems concerning detection of neutral beams were studied. Various methods were used, specifically secondary electron emissivity of a metallic surface and ionization of a gas target with a low ionization voltage. The intensities of neutral beams as low as 10 eV are measured by a tubular electron multiplier and a lock-in amplifier.

Clapier, R.↗

Wide-Range Temperature Sensors with High-Level Pulse Train Output

Two types of temperature sensors have been developed for wide-range temperature applications. The two sensors measure temperature in the range of -190 to +200 C and utilize a thin-film platinum RTD (resistance temperature detector) as the temperature-sensing element. Other parts used in the fabrication of these sensors include NPO (negative-positive- zero) type ceramic capacitors for timing, thermally-stable film or wirewound resistors, and high-temperature circuit boards and solder. The first type of temperature sensor is a relaxation oscillator circuit using an SOI (silicon-on-insulator) operational amplifier as a comparator. The output is a pulse train with a period that is roughly proportional to the temperature being measured. The voltage level of the pulse train is high-level, for example 10 V. The high-level output makes the sensor less sensitive to noise or electromagnetic interference. The output can be read by a frequency or period meter and then converted into a temperature reading. The second type of temperature sensor is made up of various types of multivibrator circuits using an SOI type 555 timer and the passive components mentioned above. Three configurations have been developed that were based on the technique of charging and discharging a capacitor through a resistive element to create a train of pulses governed by the capacitor-resistor time constant. Both types of sensors, which operated successfully over the wide temperature range, have potential use in extreme temperature environments including jet engines and space exploration missions.

Hammoud, Ahmad↗

Design and development of digital seismic amplifier recorder

A digital seismic recording is a recording technique of seismic data in digital systems. This method is more convenient because it is more accurate than other methods of seismic recorders. To improve the quality of the results of seismic measurements, the signal needs to be amplified to obtain better subsurface images. The purpose of this study is to improve the accuracy of measurement by amplifying the input signal. We use seismic sensors/geophones with a frequency of 4.5 Hz. The signal is amplified by means of 12 units of non-inverting amplifier. The non-inverting amplifier using IC 741 with the resistor values 1KΩ and 1MΩ. The amplification results were 1,000 times. The results of signal amplification converted into digital by using the Analog Digital Converter (ADC). Quantitative analysis in this study was performed using the software Lab VIEW 8.6. The Lab VIEW 8.6 program was used to control the ADC. The results of qualitative analysis showed that the seismic conditioning can produce a large output, so that the data obtained is better than conventional data. This application can be used for geophysical methods that have low input voltage such as microtremor application.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Novel Technique for Pulsed Operation of Magnetrons without Modulation of Cathode Voltage

Modern pulsed superconducting accelerators of megawatt beams require efficient RF sources controllable in phase and power. For each Superconducting RF (SRF) cavity is desirable a separate RF source with power up to hundreds of kW with pulse duration in the millisecond range. The efficiency of the traditional RF sources (klystrons, IOTs, solid-state amplifiers) is lower than that of the magnetrons, while the cost of a unit of RF power is much higher. Therefore the magnetron-based RF sources would significantly reduce the capital and operation costs in comparison with the traditional RF sources. A recently developed an innovative technique makes possible the pulsed generation of magnetrons powered below the self-excitation threshold voltage. This technique does not require pulse modulators to form RF pulses. The magnetron operation in this regime is stable, low noise, controllable in phase and power, and provides higher efficiency than other types of RF power sources. It allows operation in pulsed modes with large duty factor. The developed technique and its experimental verification are considered and discussed.

43 PARTICLE ACCELERATORS↗

Using Piezoelectric Ceramics for Dust Mitigation of Space Suits

The particles that make up moon dust and Mars soil can be hazardous to an astronaut s health if not handled properly. In the near future, while exploring outer space, astronauts plan to wander the surfaces of unknown planets. During these explorations, dust and soil will cling to their space suits and become imbedded in the fabric. The astronauts will track moon dust and mars soil back into their living quarters. This not only will create a mess with millions of tiny air-born particles floating around, but will also be dangerous in the case that the fine particles are breathed in and become trapped in an astronaut s lungs. research center are investigating ways to remove these particles from space suits. This problem is very difficult due to the nature of the particles: They are extremely small and have jagged edges which can easily latch onto the fibers of the fabric. For the past summer, I have been involved in researching the potential problems, investigating ways to remove the particles, and conducting experiments to validate the techniques. The current technique under investigation uses piezoelectric ceramics imbedded in the fabric that vibrate and shake the particles free. The particles will be left on the planet s surface or collected a vacuum to be disposed of later. The ceramics vibrate when connected to an AC voltage supply and create a small scale motion similar to what people use at the beach to shake sand off of a beach towel. Because the particles are so small, similar to volcanic ash, caution must be taken to make sure that this technique does not further inbed them in the fabric and make removal more difficult. Only a very precise range of frequency and voltage will produce a suitable vibration. My summer project involved many experiments to determine the correct range. Analysis involved hands on experience with oscilloscopes, amplifiers, piezoelectrics, a high speed camera, microscopes and computers. perfect this technology. Someday, vibration to remove dust may a vital component to the space exploration program. In order to mitigate this problem, engineers and scientists at the NASA-Glenn Further research and experiments are planned to better understand and ultimately

Angel, Heather K.↗

Biasable, Balanced, Fundamental Submillimeter Monolithic Membrane Mixer

This device is a biasable, submillimeter-wave, balanced mixer fabricated using JPL s monolithic membrane process a simplified version of planar membrane technology. The primary target application is instrumentation used for analysis of atmospheric constituents, pressure, temperature, winds, and other physical and chemical properties of the atmospheres of planets and comets. Other applications include high-sensitivity gas detection and analysis. This innovation uses a balanced configuration of two diodes allowing the radio frequency (RF) signal and local oscillator (LO) inputs to be separated. This removes the need for external diplexers that are inherently narrowband, bulky, and require mechanical tuning to change frequency. Additionally, this mixer uses DC bias-ability to improve its performance and versatility. In order to solve problems relating to circuit size, the GaAs membrane process was created. As much of the circuitry as possible is fabricated on-chip, making the circuit monolithic. The remainder of the circuitry is precision-machined into a waveguide block that holds the GaAs circuit. The most critical alignments are performed using micron-scale semiconductor technology, enabling wide bandwidth and high operating frequencies. The balanced mixer gets superior performance with less than 2 mW of LO power. This can be provided by a simple two-stage multiplier chain following an amplifier at around 90 GHz. Further, the diodes are arranged so that they can be biased. Biasing pushes the diodes closer to their switching voltage, so that less LO power is required to switch the diodes on and off. In the photo, the diodes are at the right end of the circuit. The LO comes from the waveguide at the right into a reduced-height section containing the diodes. Because the diodes are in series to the LO signal, they are both turned on and off simultaneously once per LO cycle. Conversely, the RF signal is picked up from the RF waveguide by the probe at the left, and flows rightward to the diodes. Because the RF is in a quasi- TEM (suspended, microstrip-like) mode, it impinges on the diodes in an anti-parallel mode that does not couple to the waveguide mode. This isolates the LO and RF signals. This operation is similar to a cross-bar mixer used at low frequencies, except the RF signal enters through the back-short end of the waveguide rather than through the side. The RF probe also conveys the down-converted intermediate frequency (IF) signal out to an off-chip circuit board through a simple LC low-pass filter to the left as indicated. The bias is brought to the diodes through a bypass capacitor at the top.

Siegel, Peter↗

Universal signal scaling in microwave impedance microscopy

Microwave impedance microscopy (MIM) is an emerging scanning probe technique that measures the local complex dielectric function using near-field microwave. Although it has made significant impacts in diverse fields, a systematic, quantitative understanding of the signal's dependence on various important design parameters is lacking. Here, we show that for a wide range of MIM implementations, given a complex tip-sample admittance change ΔΥ, the MIM signal—the amplified change in the reflected microwave amplitude—is –G · ΔΥ/2Υ 0 · η 2 · V in , where η is the ratio of the microwave voltage at the probe to the incident microwave amplitude, Y o is the system admittance, and G is the total voltage gain. For linear circuits, η is determined by the circuit design and does not depend on V in . We show that the maximum achievable signal for different designs scales with η 2 or η when limited by input power or sample perturbation, respectively. Furthermore, this universal scaling provides guidance on diverse design goals, including maximizing narrow-band signal for imaging and balancing bandwidth and signal strength for spectroscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SQUID Noise Measurements for CDMS Detectors

The Cryogenic Dark Matter Search is the second iteration of SuperCDMS dark matter experiments with an increase in sensitivity to low mass dark matter particles. The experiment uses germanium and silicon crystals which are capable of detecting both the charges and phonon signals produced from dark matter interactions. Detectors are housed in towers which are then housed in a cryogenics system able to cool down to 15 mK. The experiment will be installed in an underground lab in Sudbury, Ontario in order to shield from cosmic rays and background radiation. SQUIDs are an acronym for superconducting quantum interference devices that are capable of detecting extremely small magnetic fields. A typical dark matter nuclear recoil interaction can be detected by a TES (transition edge sensor). SQUIDs are then used to read out and amplify the signals generated by the TES. It is essential that these SQUIDS add negligible noise to the intrinsic noise of the TES to be able to distinguish the internal circuit noise from a true dark matter interaction signal. The noise was measured while varying several parameters. Both an Agilent and an SRS785 spectrum analyzer were used. Furthermore, an amplifier which amplified the signal 10x was tested. The Agilent machine produced more noticeably greater noise in the region from 100-1000 Hz, whereas the SRS785 did not. Next, the amplifier was tested and the signal generated was analyzed in comparison to the original signal. The amplifier did not produce any noticeable additional noise over the intrinsic noise of the SQUID. Further work includes testing to see if detectors with higher voltage sources can also be used with negligible noise.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A computer controlled signal preprocessor for laser fringe anemometer applications

The operation of most commercially available laser fringe anemometer (LFA) counter-processors assumes that adjustments are made to the signal processing independent of the computer used for reducing the data acquired. Not only does the researcher desire a record of these parameters attached to the data acquired, but changes in flow conditions generally require that these settings be changed to improve data quality. Because of this limitation, on-line modification of the data acquisition parameters can be difficult and time consuming. A computer-controlled signal preprocessor has been developed which makes possible this optimization of the photomultiplier signal as a normal part of the data acquisition process. It allows computer control of the filter selection, signal gain, and photo-multiplier voltage. The raw signal from the photomultiplier tube is input to the preprocessor which, under the control of a digital computer, filters the signal and amplifies it to an acceptable level. The counter-processor used at Lewis Research Center generates the particle interarrival times, as well as the time-of-flight of the particle through the probe volume. The signal preprocessor allows computer control of the acquisition of these data.Through the preprocessor, the computer also can control the hand shaking signals for the interface between itself and the counter-processor. Finally, the signal preprocessor splits the pedestal from the signal before filtering, and monitors the photo-multiplier dc current, sends a signal proportional to this current to the computer through an analog to digital converter, and provides an alarm if the current exceeds a predefined maximum. Complete drawings and explanations are provided in the text as well as a sample interface program for use with the data acquisition software.

Oberle, Lawrence G.↗

Universal signal conditioning amplifier

Engineers at NASA's Kennedy Space Center have designed a signal conditioning amplifier which automatically matches itself to almost any kind of transducer. The product, called Universal Signal Conditioning Amplifier (USCA), uses state-of-the-art technologies to deliver high accuracy measurements. USCA's features which can be either programmable or automated include: voltage, current, or pulsed excitation, unlimited resolution gain, digital filtering and both analog and digital output. USCA will be used at Kennedy Space Center's launch pads for environmental measurements such as vibrations, strains, temperatures and overpressures. USCA is presently being commercialized through a co-funded agreement between NASA, the State of Florida, and Loral Test and Information Systems, Inc.

Larson, William E.↗

Design of a multi beam klystron cavity from its single beam parameters

The klystron is a well-known microwave amplifier which uses kinetic energy of an electron beam for amplification of the RF signal. There are some limitations of conventional single beam klystron such as high operating voltage, low efficiency and bulky size at higher power levels, which are very effectively handled in Multi Beam Klystron (MBK) that uses multiple low purveyance electron beams for RF interaction. Each beam propagates along its individual transit path through a resonant cavity structure. Multi-Beam klystron cavity design is a critical task due to asymmetric cavity structure and can be simulated by 3D code only. The present paper shall discuss the design of multi beam RF cavities for klystrons operating at 2856 MHz (S-band) and 5 GHz (C-band) respectively. The design approach uses some scaling laws for finding the electron beam parameters of the multi beam device from their single beam counter parts. The scaled beam parameters are then used for finding the design parameters of the multi beam cavities. Design of the desired multi beam cavity can be optimized through iterative simulations in CST Microwave Studio.

42 ENGINEERING↗

Amplifier Test

For this test, we used the existing back end configuration. For the burst type signal we used the excitation system, and for the continuous type signal we used an arbitrary function generator. The frequencies of the signal are 100, 200, 300, 400 MHz. The signals were adjusted to be approximately the same level when input into the back end chain. At the MUX out load we measure the signal with a Tektronix oscilloscope, triggering on the load signal itself, recording 1K turns (fiducial triggers). The negative (${V{_{load}^{-p}}}$) and positive (${V{_{load}^{p}}}$) peak voltages generated were recorded, from which peak to peak voltages (${V{_{load}^{pp}}}$) were computed. The input signal was attenuated by 10 dB compared to the normal operating signal used for beam excitation as a cautionary measure. One measurement was made at normal operating power. We measure the loads of two amplifiers, amp 2 and amp 4.

ACCPHY↗

Triple probe signal detection electronics for systems lacking a well defined ground

Triple probes have been used to measure plasma parameters of low temperature and edge plasmas, yielding simultaneous measurements of electron temperature, ion density, and floating potential. Unlike standard Langmuir and double probe techniques, there is no requirement to sweep the probe potential relative to the plasma, thus allowing fast time resolution. However, in some plasma systems 'ground' is not well defined with respect to a known ground, may vary strongly in time, or may be at an inconveniently high voltage. The resulting high plasma (or floating) potential requires common mode rejection before the signals can be digitized. A signal detection circuit constructed from inexpensive operational amplifiers and that makes use of a novel floating bias generation configuration is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrumentation for measurement of aircraft noise and sonic boom

A jet aircraft noise and sonic boom measuring device which converts sound pressure into electric current is described. An electric current proportional to the sound pressure level at a condenser microphone is produced and transmitted over a cable, amplified by a zero drive amplifier and recorded on magnetic tape. The converter is comprised of a local oscillator, a dual-gate field-effect transistor (FET) mixer and a voltage regulator/impedance translator. A carrier voltage that is applied to one of the gates of the FET mixer is generated by the local oscillator. The microphone signal is mixed with the carrier to produce an electrical current at the frequency of vibration of the microphone diaphragm by the FET mixer. The voltage of the local oscillator and mixer stages is regulated, the carrier at the output is eliminated, and a low output impedance at the cable terminals is provided by the voltage regulator/impedance translator.

Zuckerwar, A. J.↗

Scaling a double-pulsed copper chloride laser to 10 mJ

By use of low-inductance (0.5micro H) discharge circuits, pulses of 9.6 mJ were obtained from a double-pulsed CuCl laser. An oscillator-amplifier configuration produced a pulse energy of 11 mJ. Scaling studies indicate that additional increases in the laser energy could be obtained by increasing the discharge voltage above 20 kV and/or by increasing the laser-tube dimensions.

Nerheim, N. M.↗