Search NASA⌕ Search

SEARCH · Search NASA

Results for “Verification study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Independent Verification and Validation Of SAPHIRE 8 Software Requirements Project Number: N6423 U.S. Nuclear Regulatory Commission

The purpose of the Independent Verification and Validation (IV&V) role in the evaluation of the SAPHIRE requirements definition is to assess the activities that results in the specification, documentation, and review of the requirements that the software product must satisfy, including functionality, performance, design constraints, attributes and external interfaces. The IV&V team began this endeavor after the software engineering and software development of SAPHIRE had already been in production. IV&V reviewed the requirements specified in the NRC Form 189s to verify these requirements were included in SAPHIRE’s Software Verification and Validation Plan (SVVP).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-E-T-67: A Quality Assurance Procedure for VMAT Delivery Technique with Multiple Verification Metric Using TG-119 Protocol

Purpose: A successful VMAT plan delivery includes precise modulations of dose rate, gantry rotational and multi-leaf collimator shapes. The purpose of this research is to construct routine QA protocol which focuses on VMAT delivery technique and to obtain a baseline including dose error, fluence distribution and mechanical accuracy during VMAT. Methods: The mock prostate, head and neck (HN) cases supplied from AAPM were used in this study. A VMAT plans were generated in Monaco TPS according to TG-119 protocol. Plans were created using 6 MV and 10 MV photon beams for each case. The phantom based measurement, fluence measurement and log files analysis were performed. The dose measurement was performed using 0.6 cc ion chamber, which located at isocenter. The fluence distribution were acquired using the MapCHECK2 mounted in the MapPHAN. The trajectory log files recorded inner 20 leaf pairs and gantry angle positions at every 0.25 sec interval were exported to in-house software developed by MATLAB and determined those RMS values. Results: The dose difference is expressed as a ratio of the difference between measured and planned doses. The dose difference for 6 MV was 0.91%, for 10 MV was 0.67%. In turn, the fluence distribution using gamma criteria of 2%/2 mm with a 50% minimum dose threshold for 6 MV was 98.8%, for 10 MV was 97.5%, respectively. The RMS values of MLC for 6 MV and 10 MV were 0.32 mm and 0.37 mm, of gantry were 0.33 degree and 0.31 degree. Conclusion: In this study, QA protocol to assess VMAT delivery accuracy is constructed and results acquired in this study are used as a baseline of VMAT delivery performance verification.

60 APPLIED LIFE SCIENCES↗

The effect of anterior proton beams in the setting of a prostate-rectum spacer

Studies suggest that anterior beams with in vivo range verification would improve rectal dosimetry in proton therapy for prostate cancer. We investigated whether prostate-rectum spacers would enhance or diminish the benefits of anterior proton beams in these treatments. Twenty milliliters of hydrogel was injected between the prostate and rectum of a cadaver using a transperineal approach. Computed tomography (CT) and magnetic resonance (MR) images were used to generate 7 uniform scanning (US) and 7 single-field uniform dose pencil-beam scanning (PBS) plans with different beam arrangements. Pearson correlations were calculated between rectal, bladder, and femoral head dosimetric outcomes and beam arrangement anterior scores, which characterize the degree to which dose is delivered anteriorly. The overall quality of each plan was compared using a virtual dose-escalation study. For US plans, rectal mean dose was inversely correlated with anterior score, but for PBS plans there was no association between rectal mean dose and anterior score. For both US and PBS plans, full bladder and empty bladder mean doses were correlated with anterior scores. For both US and PBS plans, femoral head mean doses were inversely correlated with anterior score. For US plans and a full bladder, 4 beam arrangements that included an anterior beam tied for the highest maximum prescription dose (MPD). For US plans and an empty bladder, the arrangement with 1 anterior and 2 anterior oblique beams achieved the highest MPD in the virtual dose-escalation study. The dose-escalation study did not differentiate beam arrangements for PBS. All arrangements in the dose-escalation study were limited by bladder constraints except for the arrangement with 2 posterior oblique beams. The benefits of anterior proton beams in the setting of prostate-rectum spacers appear to be proton modality dependent and may not extend to PBS.

61 RADIATION PROTECTION AND DOSIMETRY↗

Technical Note: Experimental carbon ion range verification in inhomogeneous phantoms using prompt gammas

Purpose: The purpose of this study was to experimentally assess the possibility to monitor carbon ion range variations—due to tumor shift and/or elongation or shrinking—using prompt-gamma (PG) emission with inhomogeneous phantoms. Such a study is related to the development of PG monitoring techniques to be used in a carbon ion therapy context. Methods: A 95 MeV/u carbon ion beam was used to irradiate phantoms with a variable density along the ion path to mimic the presence of bone and lung in homogeneous humanlike tissue. PG profiles were obtained after a longitudinal scan of the phantoms. A setup comprising a narrow single-slit collimator and two detectors placed at 90° with respect to the beam axis was used. The time of flight technique was applied to allow the selection between PG and background events. Results: Using the positions at 50% entrance and 50% falloff of the PG profiles, a quantity called prompt-gamma profile length (PGPL) is defined. It is possible to observe shifts in the PGPL when there are absolute ion range shifts as small as 1–2 mm. Quantitatively, for an ion range shift of −1.33 ± 0.46 mm (insertion of a Teflon slab), a PGPL difference of −1.93 ± 0.58 mm and −1.84 ± 1.27 mm is obtained using a BaF{sub 2} and a NaI(Tl) detector, respectively. In turn, when an ion range shift of 4.59 ± 0.42 mm (insertion of a lung-equivalent material slab) is considered, the difference is of 4.10 ± 0.54 and 4.39 ± 0.80 mm for the same detectors. Conclusions: Herein, experimental evidence of the usefulness of employing PG to monitor carbon ion range using inhomogeneous phantoms is presented. Considering the homogeneous phantom as reference, the results show that the information provided by the PG emission allows for detecting ion range shifts as small as 1–2 mm. When considering the expected PG emission from an energy slice in a carbon ion therapy scenario, the experimental setup would allow to retrieve the same PGPL as the high statistics of the full experimental dataset in 58% of the times. However, this success rate increases to 93% when using a better optimized setup by means of Monte Carlo simulations.

60 APPLIED LIFE SCIENCES↗

Generalized thermo-mechanical framework for heterogeneous materials through asymptotic homogenization

Abstract A fundamental understanding of the interaction between microstructure and underlying physical mechanisms is essential, especially for developing more accurate multi-physics models for heterogeneous materials. Effects of microstructure on the material response at the macroscale are modeled by using the generalized thermomechanics. In this study, strain gradient theory is employed as a higher-order theory on the macroscale with thermodynamics modeled as a first-order theory on the microscale. Hence, energy depends only on the temperature such that we circumvent an extension of Fourier’s law and analyze the “simplest” thermo-mechanical model in strain gradient elasticity. Developing multiphysics models for heterogeneous materials is indeed a challenge and even this “simplest” model in generalized thermomechanics creates dozens of parameters to be determined. We develop a thermo-mechanical framework, in which microstructure is modeled as a periodic structure and through asymptotic homogenization approach, higher-order parameters at macroscopic scale are calculated. To illustrate the importance of higher-order parameters in overall thermo-mechanical response of a heterogeneous materials, finite element method (FEM) is employed with the aid of open-source codes (FEniCS). Verification example of a bulk system and several case studies of porous structures demonstrate how such numerical framework can be beneficial in the design of materials with tailored microstructures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Effects of Quality Control on Decreasing Error Propagation in the LandScan USA Population Distribution Model: A Case Study of Philadelphia County

Landscan USA is a high resolution dasymetric model incorporating multiple ancillary variables to distribute populations. LandScan USA is a valuable tool in determining the population at risk during emergency response situations. However, a critical evaluation is necessary to produce user confidence regarding model accuracy through the verification and validation of model outputs. Unfortunately, dynamic models, such as population distribution, are often not validated due to the difficulty of having multiple input datasets and lack of validated data. A validated dataset allows analysis of model accuracy, as well as quantifying the benefits and costs of improving input datasets compared to find a balance for producing the best model. This paper examines inaccuracies present within the input variables of two national school datasets incorporated in the model. Schools were chosen since a validated school dataset exists for Philadelphia County, Pennsylvania. Quality control efforts utilized throughout the LandScan USA process are quantified to determine the degree of quality control necessary to have a statistically significant effect on model output. Typical LandScan USA quality control resulted in 43% of school enrollment values changed, compared to 89% for the validated dataset. Normal quality control methods resulted in 36% of schools being spatially relocated compared to 87% for the validated dataset. However, the costs of increasing quality control from normal to the validated dataset equated to a 600% increase in manual labor time for statistically insignificant improvements in LandScan USA daytime. This study enabled validation verification of not only the quality control process for LandScan USA, but also provides confidence in model output and use for policy issues, planning and emergency situations.

97 MATHEMATICS AND COMPUTING↗

Development of a one-stop beam verification system using electronic portal imaging devices for routine quality assurance

In this study, a computer-based system for routine quality assurance (QA) of a linear accelerator (linac) was developed by using the dosimetric properties of an amorphous silicon electronic portal imaging device (EPID). An acrylic template phantom was designed such that it could be placed on the EPID and be aligned with the light field of the collimator. After irradiation, portal images obtained from the EPID were transferred in DICOM format to a computer and analyzed using a program we developed. The symmetry, flatness, field size, and congruence of the light and radiation fields of the photon beams from the linac were verified simultaneously. To validate the QA system, the ion chamber and film (X-Omat V2; Kodak, New York, NY) measurements were compared with the EPID measurements obtained in this study. The EPID measurements agreed with the film measurements. Parameters for beams with energies of 6 MV and 15 MV were obtained daily for 1 month using this system. It was found that our QA tool using EPID could substitute for the film test, which is a time-consuming method for routine QA assessment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Approaching the investigation of plasma turbulence through a rigorous verification and validation procedure: A practical example

In the present work, a Verification and Validation procedure is presented and applied showing, through a practical example, how it can contribute to advancing our physics understanding of plasma turbulence. Bridging the gap between plasma physics and other scientific domains, in particular, the computational fluid dynamics community, a rigorous methodology for the verification of a plasma simulation code is presented, based on the method of manufactured solutions. This methodology assesses that the model equations are correctly solved, within the order of accuracy of the numerical scheme. The technique to carry out a solution verification is described to provide a rigorous estimate of the uncertainty affecting the numerical results. A methodology for plasma turbulence code validation is also discussed, focusing on quantitative assessment of the agreement between experiments and simulations. The Verification and Validation methodology is then applied to the study of plasma turbulence in the basic plasma physics experiment TORPEX [Fasoli et al., Phys. Plasmas 13, 055902 (2006)], considering both two-dimensional and three-dimensional simulations carried out with the GBS code [Ricci et al., Plasma Phys. Controlled Fusion 54, 124047 (2012)]. The validation procedure allows progress in the understanding of the turbulent dynamics in TORPEX, by pinpointing the presence of a turbulent regime transition, due to the competition between the resistive and ideal interchange instabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Intercomparison of wind and wave data from the ECMWF Reanalysis Interim and the NCEP Climate Forecast System Reanalysis

The recent release of the ECMWF Reanalysis Interim (ERA-I) and NCEP Climate Forecast System Reanalysis (CFSR) allows for studies of global climate and its cycles with unprecedented detail. While the developers have performed verification and validation, there is little information on their relative performance in particular related to their use in ocean modeling. This study focuses on the intercomparison of wind and wave reanalysis datasets from ERA-I and CFSR utilizing the same set of altimetry and buoy observations and error metrics to assess their consistency in time and space. Both products have good spatial homogeneity with consistent levels of errors in the Northern and Southern Hemispheres. ERA-I proves to be homogenous through time, while CFSR exhibits an abrupt decrease in the level of errors in the Southern Ocean beginning 1994. ERA-I generally underestimates the wind speed and wave height with lower standard deviations in comparison to observations, but maintains slightly better error metrics. Despite having a slightly positive bias, CFSR provides a better description of the variability of the observations and improved performance in the upper percentiles associated with extreme events. Altogether ERA-I has better homogeneity through time deeming it more reliable for modeling of long-term processes; however caution must be applied with analysis of the upper percentiles.

16 TIDAL AND WAVE POWER↗

A new method of passive counting of nuclear missile warheads -a white paper for the Defense Threat Reduction Agency

Cosmic ray muon imaging has been studied for the past several years as a possible technique for nuclear warhead inspection and verification as part of the New Strategic Arms Reduction Treaty between the United States and the Russian Federation. The Los Alamos team has studied two different muon imaging methods for this application, using detectors on two sides and one side of the object of interest. In this report we present results obtained on single sided imaging of configurations aimed at demonstrating the potential of this technique for counting nuclear warheads in place with detectors above the closed hatch of a ballistic missile submarine.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Development and Implementation of a CTF Code Verification Suite.

CTF is a thermal hydraulic subchannel code developed to predict light water reactor (LWR) core behavior. It is a version of Coolant Boiling in Rod Arrays (COBRA) developed by Oak Ridge National Laboratory (ORNL) and North Carolina State University (NCSU) and used in the Consortium for the Advanced Simulation of LWRs (CASL). Here, the existing CTF code verification matrix is expanded, which ensures that the code is a faithful representation of the underlying mathematical model. The suite of code verification tests are mapped to the underlying conservation equations of CTF and significant gaps are addressed. As such, five new problems are incorporated: isokinetic advection, conduction, pressure drop, convection, and pipe boiling. Convergence behavior and numerical errors are quantified for each of the tests and all tests converge at the correct rate to their corresponding analytic solution. A new verification utility that generalizes the code verification process is used to incorporate these problems into the CTF automated test suite.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Structural Characterization of HIV gp41 with the Membrane-proximal External Region

Human immunodeficiency virus, type 1 (HIV-1) envelope glycoprotein (gp120/gp41) plays a critical role in virus infection and pathogenesis. Three of the six monoclonal antibodies considered to have broadly neutralizing activities (2F5, 4E10, and Z13e1) bind to the membrane-proximal external region (MPER) of gp41. This makes the MPER a desirable template for developing immunogens that can elicit antibodies with properties similar to these monoclonal antibodies, with a long term goal of developing antigens that could serve as novel HIV vaccines. In order to provide a structural basis for rational antigen design, an MPER construct, HR1-54Q, was generated for x-ray crystallographic and x-ray footprinting studies to provide both high resolution atomic coordinates and verification of the solution state of the antigen, respectively. The crystal structure of HR1-54Q reveals a trimeric, coiled-coil six-helical bundle, which probably represents a postfusion form of gp41. The MPER portion extends from HR2 in continuation of a slightly bent long helix and is relatively flexible. The structures observed for the 2F5 and 4E10 epitopes agree well with existing structural data, and enzyme-linked immunosorbent assays indicate that the antigen binds well to antibodies that recognize the above epitopes. Hydroxyl radical-mediated protein footprinting of the antigen in solution reveals specifically protected and accessible regions consistent with the predictions based on the trimeric structure from the crystallographic data. Overall, the HR1-54Q antigen, as characterized by crystallography and footprinting, represents a postfusion, trimeric form of HIV gp41, and its structure provides a rational basis for gp41 antigen design suitable for HIV vaccine development.

59 BASIC BIOLOGICAL SCIENCES↗

Time-resolved in vivo luminescence dosimetry for online error detection in pulsed dose-rate brachytherapy

Purpose: The purpose of this study is to present and evaluate a dose-verification protocol for pulsed dose-rate (PDR) brachytherapy based on in vivo time-resolved (1 s time resolution) fiber-coupled luminescence dosimetry. Methods: Five cervix cancer patients undergoing PDR brachytherapy (Varian GammaMed Plus with {sup 192}Ir) were monitored. The treatments comprised from 10 to 50 pulses (1 pulse/h) delivered by intracavitary/interstitial applicators (tandem-ring systems and/or needles). For each patient, one or two dosimetry probes were placed directly in or close to the tumor region using stainless steel or titanium needles. Each dosimeter probe consisted of a small aluminum oxide crystal attached to an optical fiber cable (1 mm outer diameter) that could guide radioluminescence (RL) and optically stimulated luminescence (OSL) from the crystal to special readout instrumentation. Positioning uncertainty and hypothetical dose-delivery errors (interchanged guide tubes or applicator movements from {+-}5 to {+-}15 mm) were simulated in software in order to assess the ability of the system to detect errors. Results: For three of the patients, the authors found no significant differences (P>0.01) for comparisons between in vivo measurements and calculated reference values at the level of dose per dwell position, dose per applicator, or total dose per pulse. The standard deviations of the dose per pulse were less than 3%, indicating a stable dose delivery and a highly stable geometry of applicators and dosimeter probes during the treatments. For the two other patients, the authors noted significant deviations for three individual pulses and for one dosimeter probe. These deviations could have been due to applicator movement during the treatment and one incorrectly positioned dosimeter probe, respectively. Computer simulations showed that the likelihood of detecting a pair of interchanged guide tubes increased by a factor of 10 or more for the considered patients when going from integrating to time-resolved dose verification. The likelihood of detecting a {+-}15 mm displacement error increased by a factor of 1.5 or more. Conclusions: In vivo fiber-coupled RL/OSL dosimetry based on detectors placed in standard brachytherapy needles was demonstrated. The time-resolved dose-rate measurements were found to provide a good way to visualize the progression and stability of PDR brachytherapy dose delivery, and time-resolved dose-rate measurements provided an increased sensitivity for detection of dose-delivery errors compared with time-integrated dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fast and Accurate Core Analysis by the Full-Immersion Pressure-Pulse Decay: Part 2—Practice and Demonstration

Summary This study continues the work of presenting a novel approach for making petrophysical assessments of tight core samples. This method, the full-immersion pressure-pulse decay (Hannon 2019), involves applying a rapid increase in pressure in a chamber surrounding the entire outer surface area of a cylindrical sample, shutting the system in, and monitoring the pressure decay in the chamber as it reaches a new equilibrium. A precursor article covered the numerical simulator designed to model flow through the sample, demonstrating its performance and accuracy in addition to providing a first-order comparison between the speed and shape of the pressure-decay responses of the full-immersion method with those of other similar transient methods. This study covers the parameter-estimation procedure and experimental verification through a proof-of-concept laboratory investigation. The investigations provided here demonstrate that under appropriate, achievable experimental conditions, the pressure data can be analyzed in such a way that returns an estimate of the porosity and apparent permeabilities both parallel and perpendicular to bedding from a single test performed on a single cylindrical sample. After determining these experimental conditions (the uniqueness window), this report outlines a data-inversion strategy to estimate the petrophysical properties (porosity, horizontal permeability, and vertical permeability) from each test. This strategy is put to the test through comparisons with measurements performed by a commercial core laboratory. A common set of samples recovered from an outcrop of a tight-gas sandstone formation were investigated using the full-immersion method, and their results are compared with those from conventional steady-state measurement procedures performed by the commercial laboratory. Comparisons between petrophysical characterizations of these samples, which had permeabilities between 25 nd and 2.3 μd, demonstrated close agreement in most cases. However, whereas steady-state measurements performed at the professional laboratory required 4 to 5 hours of testing time per measurement of a single permeability, similar assessments using the full-immersion technique, requiring approximately 5 to 10 minutes to complete, returned estimates of the horizontal and vertical permeability simultaneously. Additional analyses are provided to determine principal reasons of discrepancies in instances where agreement was not as strong. Based on lessons learned from these experiences, the report closes with suggestions on areas of improvement in the experimental approach. Once complete, these developments should propel this technology to fill a critical need to determine petrophysical properties (porosity and permeability) of tight rocks in a time-efficient manner and in a way that does not compromise their accuracy.

Energy & Fuels↗

Status of R&D on Mitigating the Effects of Pressure Waves for the Spallation Neutron Source Mercury Target

The Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory has been conducting R&D on mitigating the effects of pressure waves in mercury spallation targets since 2001. More precisely, cavitation damage of the target vessel caused by the short beam pulse threatens to limit its lifetime more severely than radiation damage as well as limit its ultimate power capacity and hence its neutron intensity performance. The R&D program has moved from verification of the beam-induced damage phenomena to study of material and surface treatments for damage resistance to the current emphasis on gas injection techniques for damage mitigation. Two techniques are being worked on: injection of small dispersed gas bubbles that mitigate the pressure waves volumetrically; and protective gas walls that isolate the vessel from the damaging effects of collapsing cavitation bubbles. The latter has demonstrated good damage mitigation during in-beam testing with limited pulses, and adequate gas wall coverage at the beam entrance window has been demonstrated with the SNS mercury target flow configuration using a full scale mercury test loop. A question on the required area coverage remains which depends on results from SNS target post irradiation examination. The small gas bubble technique has been less effective during past in-beam tests but those results were with un-optimized and un-verified bubble populations. Another round of in-beam tests with small gas bubbles is planned for 2011. The first SNS target was removed from service in mid 2009 and samples were cut from two locations at the target s beam entrance window. Through-wall damage was observed at the innermost mercury vessel wall (not a containment wall). The damage pattern suggested correlation with the local mercury flow condition which is nearly stagnant at the peak damage location. Detailed post irradiation examination of the samples is under way that will assess the erosion and measure irradiation-induced changes in mechanical properties. Similar samples were cut from the second SNS target after it was removed from service in mid 2010. More extensive damage was observed on the target inner wall but damage to the containment wall was minimal.

cavitation↗

IAEA CRP on HTGR Uncertainty Analysis: Benchmark Definition and Test Cases

Uncertainty and sensitivity studies are essential elements of the reactor simulation code verification and validation process. Although several international uncertainty quantification activities have been launched in recent years in the LWR, BWR and VVER domains (e.g. the OECD/NEA BEMUSE program, from which the current OECD/NEA LWR Uncertainty Analysis in Modelling (UAM) benchmark effort was derived), the systematic propagation of uncertainties in cross-section, manufacturing and model parameters for High Temperature Reactor (HTGR) designs has not been attempted yet. This paper summarises the scope, objectives and exercise definitions of the IAEA Coordinated Research Project (CRP) on HTGR UAM. Note that no results will be included here, as the HTGR UAM benchmark was only launched formally in April 2012, and the specification is currently still under development.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Vexcel Imaging's Suitability for Automatic Verification

Accurate, independently verified geospatial data is essential for automated calibration, validation, and operational decision-making. This study evaluated the positional accuracy of Vexcel Imaging™’s UltraCam® Osprey imagery (7.5 cm GSD) using globally distributed Continuously Operating Reference Stations (CORS) as independent control. Despite manufacturer claims of 15 cm horizontal accuracy, residual errors were consistently one to two orders of magnitude larger, with no subset of imagery meeting precision thresholds. These discrepancies cannot be explained by normal photogrammetric or environmental factors and raise concerns about the reliability of the imagery for high-precision tasks. The results demonstrate that Vexcel imagery, in its current form, is unsuitable for workflows requiring rigorous spatial accuracy or automated verification. At the same time, the reproducible validation framework developed in this study establishes a scalable method for assessing commercial imagery, ensuring that future products can be independently and objectively verified before operational adoption.

47 OTHER INSTRUMENTATION↗

Center for Multiscale Plasma Dynamics: Report on Activities (UCLA/MIT), 2009-2010

The final 'phaseout' year of the CMPD ended July 2010; a no cost extension was requested until May 2011 in order to enable the MIT subcontract funds to be fully utilized. Research progress over this time included verification and validation activities for the BOUT and BOUT++ code, studies of spontaneous reconnection in the VTF facility at MIT, and studies of the interaction between Alfven waves and drift waves in LAPD. The CMPD also hosted the 6th plasma physics winter school in 2010 (jointly with the NSF frontier center the Center for Magnetic Self-Organization, significant funding came from NSF for this most recent iteration of the Winter School).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗