Search NASA⌕ Search

SEARCH · Search NASA

Results for “ambient temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Analytical study of twin-jet shielding

Progress in the refinement and evaluation of an analytical jet shielding model are summarized. The model consists of a point noise source impinging on a cylinder of heated flow in which the temperature and velocity are uniform across the cross section of the jet. The shielding jet is infinite in extent along the jet axis and the radius of the jet is constant. The analytical model was compared to experimental data for a point noise source impinging on an ambient temperature, subsonic jet and on a subsonic simulated hot jet using helium as the flow medium. Results of these comparisons are discussed.

Gerhold, C. H.↗

Ku band low noise parametric amplifier

A low noise, K sub u-band, parametric amplifier (paramp) was developed. The unit is a spacecraft-qualifiable, prototype, parametric amplifier for eventual application in the shuttle orbiter. The amplifier was required to have a noise temperature of less than 150 K. A noise temperature of less than 120 K at a gain level of 17 db was achieved. A 3-db bandwidth in excess of 350 MHz was attained, while deviation from phase linearity of about + or - 1 degree over 50 MHz was achieved. The paramp operates within specification over an ambient temperature range of -5 C to +50 C. The performance requirements and the operation of the K sub u-band parametric amplifier system are described. The final test results are also given.

Source record↗

Solar energy absorption characteristics and the effects of heat on the optical properties of several coatings

The solar energy absorption characteristics of several high temperature coatings were determined and effects of heat on these coatings were evaluated. Included in the investigation were an electroplated alloy of black chrome and vanadium, electroplated black chrome, and chemically colored 316 stainless steel. Each of the coatings possessed good selective solar energy absorption properties at laboratory ambient temperature. Measured at a temperature of 700 K (800 F), the emittances of black chrome, black chrome vanadium, and colored stainless steel were 0.11, 0.61, and 0.15, respectively. Black chrome and black chrome vanadium did not degrade optically in the presence of high heat (811 K (1000 F)). Chemically colored stainless steel showed slight optical degradation when exposed to moderately high heat (616 K (650 F)0, but showed more severe degradation at exposure temperatures beyond this level. Each of the coatings showed good corrosion resistance to a salt spray environment.

Lowery, J. R.↗

Digital control of diode laser for atmospheric spectroscopy

A system is described for remote absorption spectroscopy of trace species using a diode laser tunable over a useful spectral region of 50 to 200 cm(-1) by control of diode laser temperature over range from 15 K to 100 K, and tunable over a smaller region of typically 0.1 to 10 cm(-1) by control of the diode laser current over a range from 0 to 2 amps. Diode laser temperature and current set points are transmitted to the instrument in digital form and stored in memory for retrieval under control of a microprocessor during measurements. The laser diode current is determined by a digital to analog converter through a field effect transistor for a high degree of ambient temperature stability, while the laser diode temperature is determined by set points entered into a digital to analog converter under control of the microprocessor. Temperature of the laser diode is sensed by a sensor diode to provide negative feedback to the temperature control circuit that responds to the temperature control digital to analog converter.

Menzies, R. T.↗

Ionic Liquids and New Proton Exchange Membranes for Fuel Cells

There is currently a great surge of activity in fuel cell research as laboratories across the world seek to take advantage of the high energy capacity provided by &el cells relative to those of other portable electrochemical power systems. Much of this activity is aimed at high temperature fie1 cells, and a vital component of such &el cells must be the availability of a high temperature stable proton-permeable membrane. NASA Glenn Research Center is greatly involved in developing this technology. Other approaches to the high temperature fuel cell involve the use of single- component or almost-single-component electrolytes that provide a path for protons through the cell. A heavily researched case is the phosphoric acid fuel cell, in which the electrolyte is almost pure phosphoric acid and the cathode reaction produces water directly. The phosphoric acid fie1 cell delivers an open circuit voltage of 0.9 V falling to about 0.7 V under operating conditions at 170 C. The proton transport mechanism is mainly vehicular in character according to the viscosity/conductance relation. Here we describe some Proton Transfer Ionic Liquids (PTILs) with low vapor pressure and high temperature stability that have conductivities of unprecedented magnitude for non-aqueous systems. The first requirement of an ionic liquid is that, contrary to experience with most liquids consisting of ions, it must have a melting point that is not much above room temperature. The limit commonly suggested is 100 C. PTILs constitute an interesting class of non-corrosive proton-exchange electrolyte, which can serve well in high temperature (T = 100 - 250 C) fuel cell applications. We will present cell performance data showing that the open circuit voltage output, and the performance of a simple H2(g)Pt/PTIL/Pt/O2(g) fuel cell may be superior to those of the equivalent phosphoric acid electrolyte fuel cell both at ambient temperature and temperatures up to and above 200 C. My work at NASA Glenn Research Center during this summer is to develop and characterize proton exchange membranes doped with ionic liquids. The main techniques used to characterize these materials are: Impedance Spectroscopy, NMR, DSC, TGA, DMA, IR, and SEM ...

Belieres, Jean-Philippe↗

Hemodynamic changes during whole body surface cooling and lower body negative pressure

Six young healthy male subjects were studied to evaluate the use of whole body surface cooling (WBSC) as an antiorthostatic intervention. Previous studies have demonstrated that perfusion of an Apollo cooling garment with 16 C water produced a significant increase in stroke volume and decrease in heart rate at rest and during lower body negative pressure (LBNP). However, optimal perfusion temperatures have not been determined. The present study examined the effects of WBSC using perfusion of water at a temperature of 10 C. This perfusion temperature produced a greater decrease in mean skin temperature than water at 16 C (4 C drop compared to 2 C). The hemodynamic effects were also more prominent with 10 C water as shown by the increase in stroke volume of 11% at rest and of 35% during LBNP at -50 torr compared to control measurements at ambient temperature. Heart rates were lowered significantly (8 beats/min) and systolic arterial blood pressure was higher (8 torr). Cooling with 10 C water produced a slight increase in muscle tone, reflected by a small but significant increase (+84 ml/min) in oxygen uptake. These data suggest that WBSC is an effective nonpharmacologic means of controlling preload and deserves further investigation as an antiorthostatic intervention.

Raven, P. B.↗

Low Temperature Creep of a Titanium Alloy Ti-6Al-2Cb-1Ta-0.8Mo

This paper presents a methodology for the analysis of low temperature creep of titanium alloys in order to establish design limitations due to the effect of creep. The creep data on a titanium Ti-6Al-2Cb-1Ta-0.8Mo are used in the analysis. A creep equation is formulated to determine the allowable stresses so that creep at ambient temperatures can be kept within an acceptable limit during the service life of engineering structures or instruments. Microcreep which is important to design of precision instruments is included in the discussion also.

Chu, H. P.↗

A computer solution for the dynamic load, lubricant film thickness and surface temperatures in spiral bevel gears

A complete analysis of spiral bevel gear sets is presented. The gear profile is described by the movements of the cutting tools. The contact patterns of the rigid body gears are investigated. The tooth dynamic force is studied by combining the effects of variable teeth meshing stiffness, speed, damping, and bearing stiffness. The lubrication performance is also accomplished by including the effects of the lubricant viscosity, ambient temperature, and gear speed. A set of numerical results is also presented.

Chao, H. C.↗

Vertical resolving power of a satellite temperature sounding system

The paper examines the vertical resolving power of satellite temperature retrieval systems. Attention is given to sounding instrument proposed by Kaplan, et al., (1977) which has been conceived to have greatly improved vertical resolving capabilities. Two types of tests are reported. The first, based on the work of Conrath (1972), involves a theoretical assessment of the manner by which the ambient temperature profile is averaged over height in order to produce an estimate of temperature at a given level. The second test is empirical involving the actual retrieval of temperature signals superimposed on a standard atmosphere with an emphasis on determining the minimum separation of the signals for which the sounder system is still capable of distinguishing individual signals.

Thompson, O. E.↗

The Upper Atmosphere Research Satellite microwave limb sounder instrument

The microwave limb sounder (MLS) on the Upper Atmosphere Research Satellite (UARS) is the first satellite experiment using limb sounding techniques at microwave frequencies. Primary measurement objectives are stratospheric ClO, O3, H2O, temperature, and pressure. Measurements are of thermal emission: all are performed simultaneously and continuously and are not degraded by ice clouds or volcanic aerosols. The instrument has a 1.6-m mechanically scanning antenna system and contains heterodyne radiometers in spectral bands centred near 63, 183, and 205 GHz. The radiometers operate at ambient temperature and use Schottky-diode mixers with local oscillators derived from phase-locked Gunn oscillators. Frequency tripling by varactor multipliers generates the 183- and 205-GHz local oscillators, and quasi-optical techniques inject these into the mixers. Six 15-channel filter banks spectrally resolve stratospheric thermal emission lines and produce an output spectrum every 2 s. Thermal stability is sufficient for 'total power' measurements which do not require fast chopping. Radiometric calibration, consisting of measurements of cold space and an internal target, is performed every 65-s limb scan. Instrument in-orbit performance has been excellent, and all objectives are being met.

Barath, F. T.↗

Dynamic Mechanical Properties and Fracture Surface Morphologies of Core-Shell Rubber (CSR) Toughened Epoxy at Liquid Nitrogen (Ln2) Temperatures

The dynamic mechanical properties and fracture surface morphologies were evaluated for a commercial epoxy resin toughened with two types of core-shell rubber (CSR) toughening agents (Kane Ace(Registered TradeMark) MX130 and MX960). The impact resistance (R) was evaluated by the resulting breaking energy measured in Charpy impact tests conducted on an instrumented drop tower. The resulting fracture surface morphologies were examined using Scanning Electron Microscopy (SEM). Fractographic observations of the CSR toughened epoxy tested at ambient temperature, showed a fracture as characterized by slender dendrite textures with large voids. The increasing number of dendrites and decreasing size of scale-like texture with more CSR particles corresponded with increased R. As the temperature decreased to Liquid Nitrogen (LN 2), the fracture surfaces showed a fracture characterized by a rough, torn texture containing many river markings and deep furrows.

Wang, J.↗

Data Processing and Experimental Design for Micrometeorite Impacts in Small Bodies

Comets and asteroids have been altered from their original "pristine" state by impacts occurring throughout their 4.5 billion year lives: [1]. Proof of shock deformation has been detected in the crystal structure of several Stardust samples from Comet Wild 2 [2, 3]. Analyses indicated that the planar dislocations in the crystal structure of the minerals had been imparted by impacts sustained during their lives, and not due to the aerogel capture process. Distortions to crystal structure also affect the ideal absorption spectra in the infrared, and [4], thus providing indirect evidence of its impact history and a means of remotely investigating the impact history of small bodies through comparing laboratory spectra with spectra observed by telescopes or spacecraft. -The effects of impacts propagating shock waves through minerals were investigated through laboratory impact experiments. Utilizing NASA Johnson Space Center's Experimental Impact Laboratory, projectiles were fired from the vertical gun at velocities ranging from 2.0 to 2.8 km/sec, projected impact velocities between Kuiper Belt Objects. Two types of projectiles were used, including spherical alumina ceramic, whose density mimics that of rock, and cylinders made from the same material that they impacted. The target materials chosen for testing included: OLIVINES forsterite (Mg2SiO4) and fayalite, Fe2SiO4); PYROXENES enstatite (Mg2Si2O6) and diopside (MgCaSi2O6); and CARBONATES magnesite (MgCO3) and siderite (FeCO3). Targets were impacted at either 25 C or cooled to -20 C to examine the effects of temperature, if any, on lattice distortions during the shock propagation. As comets and asteroids can undergo a wide range of temperatures in their orbital lifetimes, the effect of temperature on the equation of state of minerals being shocked needs to be examined for interpreting the results of these experiments. The porosity of the target mineral is varied by either grinding it into a powder/granular texture or as whole mineral rocks to investigate the differences in shock propagation when voids are present. By varying velocity, ambient temperature, and porosity, we can investigate different variables affecting impacts in the solar system. -Data indicates that there is a non-linear relationship between peak shock pressure and the variation in infrared spectral absorbances by the distorted crystal structure. The maximum variability occurs around 37 GPa in enstatite and forsterite. The particle size distribution of the impacted material similarly changes with velocity/peak shock pressure. -The experiments described above are designed to measure the near- to mid-IR effects from these changes to the mineral structure. See Lederer et al., this meeting for additional experimental results.

Jensen, E.↗

Pre-exercise glycerol hydration improves cycling endurance time

The effects of glycerol ingestion (GEH) on hydration and subsequent cycle ergometer submaximal load exercise were examined in well conditioned subjects. We hypothesized that GEH would reduce physiologic strain and increase endurance. The purpose of Study I (n = 11) was to determine if pre-exercise GEH (1.2 gm/kg glycerol in 26 ml/kg solution) compared to pre-exercise placebo hydration (PH) (26 ml/kg of aspartame flavored water) lowered heart rate (HR), lowered rectal temperature (Tc), and prolonged endurance time (ET) during submaximal load cycle ergometry. The purpose of Study II (n = 7) was to determine if the same pre-exercise regimen followed by carbohydrate oral replacement solution (ORS) during exercise also lowered HR, Tc, and prolonged ET. Both studies were double-blind, randomized, crossover trials, performed at an ambient temperature of 23.5-24.5 degrees C, and humidity of 25-27%. Mean HR was lower by 2.8 +/- 0.4 beats/min (p = 0.05) after GEH in Study I and by 4.4 +/- 1.1 beats/min (p = 0.01) in Study II. Endurance time was prolonged after GEH in Study I (93.8 +/- 14 min vs. 77.4 +/- 9 min, p = 0.049) and in Study II (123.4 +/- 17 min vs. 99.0 +/- 11 min, p = 0.03). Rectal temperature did not differ between hydration regimens in both Study I and Study II. Thus, pre-exercise glycerol-enhanced hyperhydration lowers HR and prolongs ET even when combined with ORS during exercise. The regimens tested in this study could potentially be adapted for endurance activities.

Non-NASA Center↗

Pressure-Fed LOX/LCH4 Reaction Control System for Spacecraft: Transient Modeling and Thermal Vacuum Hotfire Test Results

An integrated cryogenic liquid oxygen, liquid methane (LOX/LCH4) reaction control system (RCS) was tested at NASA Glenn Research Center's Plum Brook Station in the Spacecraft Propulsion Research Facility (B-2) under vacuum and thermal vacuum conditions. The RCS is a subsystem of the Integrated Cryogenic Propulsion Test Article (ICPTA), a pressure-fed LOX/LCH4 propulsion system composed of a single 2,800 lbf main engine, two 28 lbf RCS engines, and two 7 lbf RCS engines. Propellants are stored in four 48 inch diameter 5083 aluminum tanks that feed both the main engine and RCS engines in parallel. Helium stored cryogenically in a composite overwrapped pressure vessel (COPV) flows through a heat exchanger on the main engine before being used to pressurize the propellant tanks to a design operating pressure of 325 psi. The ICPTA is capable of simultaneous main engine and RCS operation. The RCS engines utilize a coil-on-plug (COP) ignition system designed for operation in a vacuum environment, eliminating corona discharge issues associated with a high voltage lead. There are two RCS pods on the ICPTA, with two engines on each pod. One of these two engines is a heritage flight engine from Project Morpheus. Its sea level nozzle was removed and replaced by an 85:1 nozzle machined using Inconel 718, resulting in a maximum thrust of 28 lbf under altitude conditions. The other engine is a scaled down version of the 28 lbf engine, designed to match the core and overall mixture ratios as well as other injector characteristics. This engine can produce a maximum thrust of 7 lbf with an 85:1 nozzle that was additively manufactured using Inconel 718. Both engines are film-cooled and capable of limited duration gas-gas and gas-liquid operation, as well as steady-state liquid-liquid operation. Each pod contains one of each version, such that two engines of the same thrust level can be fired as a couple on opposite pods. The RCS feed system is composed of symmetrical 3/8 inch lines that tap off of the main propellant manifold to send LOX and LCH4 outboard to the RCS pods. A Thermodynamic Vent System (TVS) is used to condition propellants at each pod by venting through an orifice and then routing the cold expansion products back through tubing that is welded along a large portion of the main RCS feed lines. Prior to final installation on the ICPTA, the RCS engines were tested in a small vacuum chamber at the Johnson Space Center (JSC) Energy Systems Test Area (ESTA) to verify functionality of the new COP ignition system and check out operation of the vacuum nozzles. After engine-level testing, the RCS engines were installed on the vehicle and a series of integrated hot-fire tests were performed at JSC consisting of various pulsing and steady-state firings as well as integrated main engine/RCS operation. The ICPTA was then integrated into the Plum Brook B-2 facility for vacuum and thermal/vacuum testing. Testing in the B-2 facility was composed of multiple thermal and pressure environments. The first set of tests were performed under ambient temperature and altitude pressure conditions. These tests consisted of a range of minimum impulse bit (MIB) pulsing sequences with low duty cycle, analogous to a coast phase in which the RCS is primarily used for station keeping. The primary goal of this sequence is to understand how propellant conditions were effected without an active TVS. In this scenario, consistent gas-gas operation is desirable since it results in a smaller MIB and more efficient propellant consumption. Multiple skin thermocouples are mounted on the feedlines, in addition to a submerged thermocouple on each commodity, in order to gather thermal data on the system. Higher duty cycle pulsing tests were then performed, analogous to an ascent or landing mission phase. The primary goal of this sequence was to examine how well the engines self-conditioned without active TVS when starting from a quiescent state. The TVS was then activated during some tests to demonstrate the capability to quickly condition the engines for higher pulsing demand scenarios. A thermocouple at the TVS outlet allows for the calculation of energy absorbed by the vented propellant. Lastly, tests with longer pulses and multiple engines firing either in sequence or simultaneously were run in order to gather transient system response data on waterhammer. Six total high-speed pressure transducers are installed on the RCS system, one sensor at the end of each propellant manifold line on the pods, and one at the tap-off location for each commodity. This will allow for the accurate characterization of waterhammer in the system under various propellant conditions and firing sequences. Other instrumentation for this test series includes nozzle throat thermocouples, chamber pressure measurement, heat soakback measurement, and tank wall plume impingement temperature measurement. The next set of tests were performed to demonstrate simultaneous main engine and RCS operation. Data from this test will be used to examine if there is any change to nominal operation of the RCS as a result of feed system interaction or other phenomenon. Some of these tests began under high vacuum conditions (target ambient pressure less than 1x10(exp -3) torr) and others began at altitude conditions. The last set of tests were performed with the B-2 cold wall active. Under these tests, many of the same low duty cycle MIB tests were repeated in order to characterize how propellant conditions changed with the lower heat leak. In this scenario the RCS manifold experiences much less heat leak, resulting in a change to how well the engines self-condition. As a result, an increase in maximum waterhammer pressures and a change in natural frequency of the system was expected due to higher density propellants. The lower heat leak should also result in a change to the MIB pulse profile, and data will be examined to understand how MIB repeatability is affected in the different operating environments. Parallel to the test efforts, a set of transient model development efforts were made to predict RCS performance. The primary effort was aimed at producing a SINDA/FLUINT model to predict propellant conditioning up to the engine inlet as a function of different environmental and operating parameters, with the goal of predicting chamber pressure, TVS performance, and propellant consumption over time. Preliminary results for this effort will be presented in comparison with test data. Additional modeling efforts were made using SINDA/FLUINT to predict waterhammer in the system since the software is capable of handling multiphase transient fluid dynamics. These results will be compared with the high-speed pressure transducer test data for validation purposes.

Atwell, Matthew J.↗

Detector Control and Data Acquisition for the Wide-Field Infrared Survey Telescope (WFIRST) with a Custom ASIC

The Wide-Field Infrared Survey Telescope (WFIRST) will have the largest near-IR focal plane ever flown by NASA, a total of 18 4K x 4K devices. The project has adopted a system-level approach to detector control and data acquisition where 1) control and processing intelligence is pushed into components closer to the detector to maximize signal integrity, 2) functions are performed at the highest allowable temperatures, and 3) the electronics are designed to ensure that the intrinsic detector noise is the limiting factor for system performance. For WFIRST, the detector arrays operate at 90 to 100 K, the detector control and data acquisition functions are performed by a custom ASIC at 150 to 180 K, and the main data processing electronics are at the ambient temperature of the spacecraft, notionally approx.300 K. The new ASIC is the main interface between the cryogenic detectors and the warm instrument electronics. Its single-chip design provides basic clocking for most types of hybrid detectors with CMOS ROICs. It includes a flexible but simple-to-program sequencer, with the option of microprocessor control for more elaborate readout schemes that may be data-dependent. All analog biases, digital clocks, and analog-to-digital conversion functions are incorporated and are connected to the nearby detectors with a short cable that can provide thermal isolation. The interface to the warm electronics is simple and robust through multiple LVDS channels. It also includes features that support parallel operation of multiple ASICs to control detectors that may have more capability or requirements than can be supported by a single chip.

data acquisition↗

Effect of outdoor exposure at ambient and elevated temperatures on fatigue life of Ti-6Al-4V titanium alloy sheet in the annealed and the solution treated and aged condition

Specimens of Ti-6Al-4V titanium alloy sheet in the annealed and the solution-treated and aged heat-treatment condition were exposed outdoors at ambient and 560 K (550 F) temperatures to determine the effect of outdoor exposure on fatigue life. Effects of exposure were determined by comparing fatigue lives of exposed specimens to those of unexpected specimens. Two procedures for fatigue testing the exposed specimens were evaluated: (1) fatigue tests conducted outdoors by applying 1200 load cycles per week until failure occurred and (2) conventional fatigue tests (continuous cycling until failure occurred) conducted indoors after outdoor exposure under static load. The exposure period ranged from 9 to 28 months for the outdoor fatigue-test group and was 24 months for the static-load group. All fatigue tests were constant-amplitude bending of specimens containing a drilled hole (stress concentration factor of 1.6). The results of the tests indicate that the fatigue lives of solution-treated and aged specimens were significantly reduced by the outdoor exposure at 560 K but not by the exposure at ambient temperature. Fatigue lives of the annealed specimens were essentially unaffected by the outdoor exposure at either temperature. The two test procedures - outdoor fatigue test and indoor fatigue test after outdoor exposure - led to the same conclusions about exposure effects.

Phillips, E. P.↗

Influence of Ice-phase of Hydrometeors on Moist-Convection

Climate models often ignore the influence of ice-phase physics (IPP) of hydrometeors as a second order effect. This has also been true for McRAS (Microphysics of clouds with Relaxed Arakawa Schubert Scheme) developed by the authors. Recognizing that the temperature sounding is critical for moist-convection, and, that IPP would modify it, we investigated the influence of introducing IPP into McRAS coupled to FvGCM (finite volume General Circulation Model with NCAR physics). We analyzed three 3-yr long simulations; the first called Control Case, CC and had no IPP; the other two called Experiments El and E2 had IPP introduced with two different in-cloud freezing assumptions. Simulation El assumed that all hydrometeors remain liquid in the updraft and freeze upon detrainment. Simulation E2 invoked the in-cloud freezing of new condensate generated at subfreezing temperatures in the updraft while old cloud water continued to ascend as liquid. Upon detrainment, this cloud water also froze like in E1. With these assumptions, about 50% of hydrometeors froze in the tower and the rest froze in the anvil. However, in both El and E2, the frozen hydrometeors melted during fall at the first encounter of above freezing ambient temperature. Comparative analysis revealed that El simulated far more mid-level and far less deep clouds while E2 had modified deep and more mid-level clouds as compared to CC along with some major changes around the melt-level. We infer that IPP produced a more realistic response in E2. At the basic level, the results show that ice-phase processes influence convective detrainment at mid- and deep levels in accord with TOGAGOARE observations. The results suggest that IPP can help to mitigate less-than-observed mid-level and over-abundance of deep convective clouds in McRAS.

Sud, Y. C.↗