Evaluation of Technologies for Destruction of LDR Organics in Hanford Tank Waste
Aqueous Hanford tank wastes contain soluble organics and some tanks contain small amounts (<100 mg/L) of organics that are regulated under the Land Disposal Restrictions (LDR) portions of the Resource Conservation and Recovery Act (RCRA). Most of these organics can be removed by evaporation, but some are not. Methods to destroy/remove organics that are regulated by the LDR section of the RCRA and that are not removed by evaporation may be needed if ambient temperature waste treatment processes are used to immobilize aqueous Hanford tank wastes. To identify viable and compatible organic removal or destruction pretreatment methods an evaluation was performed by a team of researchers. The team utilized a Systems Engineering Approach that examines all aspects of the technology, based on information available in the literature and the experience of the team members. That evaluation led to recommendations by the team to perform testing on technologies to determine efficacy in destroying organics in Hanford tank waste liquids. The primary technologies recommended are chemical oxidants, including permanganate, peroxymonosulfate or peroxydisulfate (PMS/PDS), hydrogen peroxide, and ozone. Ultraviolet light irradiation of the stream with a solid catalyst sorbent is also recommended for testing. A generalized description of the test program is also included.