Optical implementation of systolic array processing

Algorithms for matrix vector multiplication are implemented using acousto-optic cells for multiplication and input data transfer and using charge coupled devices detector arrays for accumulation and output of the results. No two dimensional matrix mask is required; matrix changes are implemented electronically. A system for multiplying a 50 component nonnegative real vector by a 50 by 50 nonnegative real matrix is described. Modifications for bipolar real and complex valued processing are possible, as are extensions to matrix-matrix multiplication and multiplication of a vector by multiple matrices.

Caulfield, H. J.↗

Novel Si(1-x)Ge(x)/Si heterojunction internal photoemission long wavelength infrared detectors

There is a major need for long-wavelength-infrared (LWIR) detector arrays in the range of 8 to 16 microns which operate with close-cycle cryocoolers above 65 K. In addition, it would be very attractive to have Si-based infrared (IR) detectors that can be easily integrated with Si readout circuitry and have good pixel-to-pixel uniformity, which is critical for focal plane array (FPA) applications. Here, researchers report a novel Si(1-x)Ge(x)/Si heterojunction internal photoemission (HIP) detector approach with a tailorable long wavelength infrared cutoff wavelength, based on internal photoemission over the Si(1-x)Ge(x)/Si heterojunction. The HIP detectors were grown by molecular beam epitaxy (MBE), which allows one to optimize the device structure with precise control of doping profiles, layer thickness and composition. The feasibility of a novel Si(1-x)Ge(x)/Si HIP detector has been demonstrated with tailorable cutoff wavelength in the LWIR region. Photoresponse at wavelengths 2 to 10 microns are obtained with quantum efficiency (QE) above approx. 1 percent in these non-optimized device structures. It should be possible to significantly improve the QE of the HIP detectors by optimizing the thickness, composition, and doping concentration of the Si(1-x)Ge(x) layers and by configuring the detector for maximum absorption such as the use of a cavity structure. With optimization of the QE and by matching the barrier energy to the desired wavelength cutoff to minimize the thermionic current, researchers predict near background limited performance in the LWIR region with operating temperatures above 65K. Finally, with mature Si processing, the relatively simple device structure offers potential for low-cost producible arrays with excellent uniformity.

Lin, T. L.↗

Techniques for gamma rays.

The detecting systems used in high energy astrophysics are generally more similar to particle detectors than to optical devices. The basic design of the gamma ray instrument depends on whether the energy range is below about 10 MeV and therefore in the region where the Compton effect predominates in the absorption of the gamma-rays, or above that energy where electron-positron pair production is most important. The most usual approach to the detector system in the lower of the two energy intervals is to use a scintillation counter in the center of the detector system to absorb the photons and permit a measure of their energy, and to surround it by another detector which is employed as an active anticoincidence shield to discriminate against charged particles. In the gamma-ray interval above about 10 MeV, the very low flux of gamma rays and the high particle background has directed the development of high energy gamma-ray telescopes towards complicated techniques and large detector arrays. As a result, several investigators have now turned to the spark chamber as the heart of a detector system. Generally, it is surrounded by an anticoincidence system and is triggered by a counter telescope.

Fichtel, C. E.↗

The Atacama Cosmology Telescope: The Receiver and Instrumentation

The Atacama Cosmology Telescope was designed to measure small-scale anisotropies in the Cosmic Microwave Background and detect galaxy clusters through the Sunyaev-Zel'dovich effect. The instrument is located on Cerro Taco in the Atacama Desert, at an altitude of 5190 meters. A six-met.er off-axis Gregorian telescope feeds a new type of cryogenic receiver, the Millimeter Bolometer Array Camera. The receiver features three WOO-element arrays of transition-edge sensor bolometers for observations at 148 GHz, 218 GHz, and 277 GHz. Each detector array is fed by free space mm-wave optics. Each frequency band has a field of view of approximately 22' x 26'. The telescope was commissioned in 2007 and has completed its third year of operations. We discuss the major components of the telescope, camera, and related systems, and summarize the instrument performance.

Swetz, D. S.↗

DUMAND Summer Workshop, University of California, La Jolla, Calif., July 24-September 2, 1978, Proceedings. Volume 1 - Array studies

Papers are presented concerning the design and implementation of the optical and acoustic sensors that will comprise the DUMAND (Deep Underwater Muon and Neutrino Detector) array. Specific topics include the results of experiments on atmospheric muon and neutrino spectra obtained with various muon and neutrino spectrometers, optical sensors and arrays, optical data handling systems, the simulation of the sound generated by high-energy particles in water, constraints on acoustic arrays, standard ocean parameters for DUMAND calculations, and Monte Carlo investigations of hadronic and electromagnetic cascades in sea water.

Roberts, A.↗

Performance Testing of the Astro-H Flight Model 3-Stage ADR

The Soft X-ray Spectrometer (SXS) is one of four instruments that will be flown on the Japanese Astro-H satellite, planned for launch in late 2015early 2016. The SXS will perform imaging spectroscopy in the soft x-ray band using a 6x6 array of silicon micro calorimeters operated at 50 mK, cooled by an adiabatic demagnetization refrigerator (ADR). NASAGSFC is providing the detector array and ADR, and Sumitomo Heavy Industries, Inc. is providing the remainder of the cryogenic system (superfluid helium dewar (1.3 K), Stirling cryocoolers and a 4.5 K Joule-Thomson (JT) cryocooler). The ADR is unique in that it is designed to use both the liquid helium and the JT cryocooler as it heat sink. The flight detector and ADR assembly have successfully undergone vibration and performance testing at GSFC, and have now undergone initial performance testing with the flight dewar at Sumitomo Heavy Industries, Inc. in Japan. This presentation summarizes the performance of the flight ADR in both cryogen-based and cryogen-free operating modes.

adiabatic demagnetization refrigerator↗

An Imaging Interferometer for Terrestrial Remote Sensing

A prototype imaging interferometer called DASI (digital array scanned interferometer) is under development at our laboratories. Our objective is to design an instrument for remote sensing of Earth's atmosphere and surface. This paper describes the unusual characteristics of DASIs which make them promising candidates for ground and aircraft-based terrestrial measurements. These characteristics include superior signal-to-noise, design simplicity and compactness, relative to dispersion based imaging spectrometers. Perhaps one of the most notable features of DASIs is their ability to acquire an entire interferogram simultaneously without any moving optical elements. We also describe selected laboratory and ground based field measurements using the prototype DASI. A CCD detector array was placed at the DASI detector plane for wavelength coverage from 0.4 to 1.0 micron. A NICMOS MCT detector was used for coverage from 1.1 to 2.2 micron. The DASI was configured to have a spectral resolution of about 300 1/cm, a spatial field of view of 5 degrees, and a constant number of transverse spatial elements (detector dependent) for each exposure frame. Frame exposure rates were up to 0.6 Hz with the potential to achieve 5 Hz. Image cube measurements of laboratory targets and terrestrial scenes were obtained by multiple frame scanning over the field of view. These data sets reveal the potential science yields from obtaining simultaneous high resolution spatial and spectral information.

Hammer, Philip D.↗

Design and Deployment of a Multichroic Polarimeter Array on the Atacama Cosmology Telescope

We present the design and the preliminary on-sky performance with respect to beams and pass bands of a multichroic polarimeter array covering the 90 and 146 GHz cosmic microwave background bands and its enabling broad-band optical system recently deployed on the Atacama Cosmology Telescope (ACT). The constituent pixels are feedhorn-coupled multichroic polarimeters fabricated at NIST. This array is coupled to the ACT telescope via a set of three silicon lenses incorporating novel broad-band metamaterial anti-reflection coatings. This receiver represents the first multichroic detector array deployed for a CMB experiment and paves the way for the extensive use of multichroic detectors and broad-band optical systems in the next generation of CMB experiments.

passbands↗

SAFIRE: A Far-Infrared Imaging Spectrometer for SOFIA

The SOFIA airborne observatory will provide a high spatial resolution, low background telescope for far-infrared astrophysical investigations. Selected as a PI instrument for SOFIA, SAFIRE is an imaging Fabry-Perot spectrograph covering 145 micrometers-655 micrometers with spectral resolving power of approx. 1500 (200km/s). This resolution is well matched to extragalactic emission lines and yields the greatest sensitivity for line detection. SAFIRE will make important scientific contributions to the study of the powering of ULIRGs and AGN, the role of CII cooling in extragalactic star formation, the evolution of matter in the early Universe, and the energetics of the Galactic center. SAFIRE will employ a two-dimensional pop-up bolometer array to provide background-limited imaging spectrometry. Superconducting transition edge bolometers and SQUID amplifiers have been developed for these detectors. An engineering prototype of SAFIRE with a small but cutting edge detector array will be available for use during the initial SOFIA operations; further expansion to larger format arrays will be incorporated during SAFIRE's lifetime.

Shafer, Richard A.↗

An Imaging Laser Altimeter for Lunar Scientific Exploration

A new approach to laser altimetry is offered by the development of micro-lasers and pixilated detectors that enable very high resolution measurement of topography and relatively wide swath observations. An imaging altimeter with a 8x8 array detector working at a probability of less than a single photon/shot could map the Moon or similar sized body in approximately 2 years and provide 5 meter horizontal resolution topography and a 10 centimeter vertical accuracy. In addition, it would provide surface roughness and surface slopes on similar length scales of 5 meters and be able to address a range of problems for which topography or lunar shape is important at the decimeter level. This includes the topography of the polar regions, where ice is thought to have been identified, and also the cratering history of the Moon which could be assessed with a dataset of uniform quality and high resolution.

Source record↗

An Imaging Laser Altimeter for Lunar Scientific Exploration

A new approach to laser altimetry is offered by the development of micro-lasers and pixilated detectors that enable very high resolution measurement of topography and relatively wide swath observations. An imaging altimeter with a 8x8 array detector working at a probability of less than a single photon/shot could map the Moon or similar sized body in approximately 2 years and provide 5 meter horizontal resolution topography and a 10 centimeter vertical accuracy. In addition, it would provide surface roughness and surface slopes on similar length scales of 5 meters and be able to address a range of problems for which topography or lunar shape is important at the decimeter level. This includes the topography of the polar regions, where ice is thought to have been identified, and also the cratering history of the Moon which could be assessed with a dataset of uniform quality and high resolution.

Smith, David E.↗

Experiments in infrared multispectral mapping of earth resources

Two evolutionary infrared remote sensing experiments provide the basis for the development of an operational mapping capability for geology exploration. A 10-band radiometer scheduled for an early Shuttle flight has completed an aircraft flight program which demonstrated the utility of a number of narrow spectral channels. A multispectral mapper utilizing an infrared area array detector to acquire simultaneous images in multiple wavelengths is being assembled. A design concept for an operational sensor which employs area arrays for registered multispectral image data acquisition is under study. The sensor would utilize onboard spectral band selection, radiometric correction, and data compression to satisfy the demanding requirements of the user community.

Wellman, J. B.↗

Development of an End-to-End Demonstration Readout Chain for Athena-X-IFU

The X-IFU (X-ray Integral Field Unit) of the Athena (Advanced Telescope for High-ENergy Astrophysics) telescope, scheduled for launch in the early 2030's, will provide X-ray spectroscopy data with unprecedented spectral and spatial resolution. This will be achieved by a 3 kilo-pixel array of TES (transition-edge sensor) microcalorimeters. The complete detection chain is under development by a large international collaboration. The detector array will be provided by NASA Goddard Space Flight Center, the cold TDM (time domain multiplexing) electronics by NIST, the cold amplifier by VTT, the cold focal-plane assembly by SRON, the warm front-end electronics by APC, and the DRE (digital readout electronics) by IRAP. In order to perform an end-to-end demonstration of the X-IFU readout chain, a 50 mK test bench is being developed at IRAP in collaboration with CNES. The test bench is based on a two-stage ADR cryostat from Entropy GmbH and a 1024-pixel array from Goddard associated with its cold TDM readout from NIST. The setup will initially be validated using a warm electronic chain from NIST and Goddard. We will describe the complete system being installed in the cryostat and the first results obtained with these electronics. We will also review the status of the integration of the DRE prototype in the demonstration chain and the way forward in the integration and testing of the complete X-IFU readout chain.

S Beaumont↗

Astronomical application of IR CID technology

A portable microcomputer data system was developed to test a 2 x 64-element Si:Bi charge injection device (CID) infrared detector array on the Lick Observatory Shane telescope. An existing 0.5 m spectrograph was used for the tests after modification, and a spectral resolution of 1000 was achieved. Slow device response, due to the low background conditions in the spectrograph were shown. Astronomical data were later obtained, and a device read noise on the order of a few hundred electrons was achieved. The signal to noise ratios of the resulting spectra were about a factor of five lower than what could have been achieved with discrete photoconductive detectors. It is concluded that the CID array is competitive for applications in backgrounds lower than those used in the tests.

Rank, D. M.↗

Getting NuSTAR on Target: Predicting Mast Motion

The Nuclear Spectroscopic Telescope Array (NuSTAR) is the first focusing high energy (3-79 keV) X-ray observatory operating for four years from low Earth orbit. The X-ray detector arrays are located on the spacecraft bus with the optics modules mounted on a flexible mast of 10.14m length. The motion of the telescope optical axis on the detectors during each observation is measured by a laser metrology system and matches the pre-launch predictions of the thermal flexing of the mast as the spacecraft enters and exits the Earths shadow each orbit. However, an additional motion of the telescope field of view was discovered during observatory commissioning that is associated with the spacecraft attitude control system and an additional flexing of the mast correlated with the Solar aspect angle for the observation. We present the methodology developed to predict where any particular target coordinate will fall on the NuSTAR detectors based on the Solar aspect angle at the scheduled time of an observation. This may be applicable to future observatories that employ optics deployed on extendable masts. The automation of the prediction system has greatly improved observatory operations efficiency and the reliability of observation planning.

NASA small explorer↗

Cassini CIRS Observations of Iapetus' Thermal Emission

Cassini s Composite Infrared Spectrometer (CIRS, [1]) mapped Iapetus thermal emission from 7 to approx.300 microns during the spacecraft s December 31st 2004 flyby of the satellite. Short-wavelength spectra were obtained with the CIRS "FP3" (10 - 17 micron) and "FP4" (7 - 10 micron) detector arrays, each consisting of 1 x 10 pixels with a spatial resolution of 0.29 milliradians, while longer wavelength observations used the "FP1" detector, with a single-aperture detector with 4 milliradian diameter. The detectors are scanned across the target to build up an image cube with two spatial dimensions and one spectral dimension. CIRS daytime observations covered the dark terrain of Cassini Regio, except for high northern latitudes which were occupied by bright terrain, while nighttime observations covered a mixture of bright and dark terrain. The 120,000 km flyby distance provided a maximum spatial resolution of 35 km in the FP3 and FP4 detectors, and 500 km in the FP1 detector.

Spencer, J. R.↗

Observations of a gamma-ray burst and other sources with a large-area, balloon-borne detector

Observations of a weak cosmic gamma ray burst of integrated intensity 2 x 10 to the -6th erg/sq cm, two solar flare events, and pulsed emission profiles of A0535+26 and NP0532 are reported for several energy intervals in the energy range from 45 to 520 keV. The measurements were made with a NaI(Tl) detector array flown on a balloon to 4 g/sq cm residual atmosphere from Palestine, Texas, on October 6-8, 1980, for 28 hours. The detector is a prototype of the Burst and Transient Source Experiment (BATSE) to be flown on the Gamma-Ray Observatory (GRO).

Wilson, R. B.↗