At least 415 records · Page 23

Development of a low-pressure Multi-Mesh THGEM detector for fission experiments at FRIB

Abstract A small-area imaging detector prototype for position measurement of fission fragments produced in low energy heavy-ion reactions is presented in this study. The detector readout is equipped with a 2-dimensional, position-sensitive gaseous avalanche readout based on the novel Multi-Mesh Thick-GEM (MM-THGEM), and is coupled to a delay-line board for particle localization. The prototype has an effective area of 10 × 10 cm 2 and is operated in isobutane at low pressure (7–10 Torr). We present and discuss a series of systematic evaluation tests performed by irradiating the detector with α-particles and fission fragments emitted by small-rate sources ( 241 Am, 249 Cf and 252 Cf). Position and time resolutions of about 0.42 mm and 1 ns were achieved, respectively. This work serves as a benchmark for the development of a large-scale array of detectors for experiments with fission and fission-like reaction products at the Facility for Rare Isotope Beams (FRIB).

Instruments & Instrumentation↗

Characterization of a SiPM-based monolithic neutron scatter camera using dark counts

The Single Volume Scatter Camera (SVSC) Collaboration aims to develop portable neutron imaging systems for a variety of applications in nuclear non-proliferation. Conventional double-scatter neutron imagers are composed of several separate detector volumes organized in at least two planes. A neutron must scatter in two of these detector volumes for its initial trajectory to be reconstructed. As such, these systems typically have a large footprint and poor geometric efficiency. We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm×56 mm× 60 mm monolithic block of EJ-204 plastic scintillator instrumented on two faces with arrays of 64 Hamamatsu S13360-6075PE silicon photomultipliers (SiPMs). The electronic crosstalk is limited to < 5% between adjacent channels and < 0.1% between all other channel pairs. SiPMs introduce a significantly elevated dark count rate over PMTs, as well as correlated noise from after-pulsing and optical crosstalk. In this article, we characterize the dark count rate and optical crosstalk and present a modified event reconstruction likelihood function that accounts for them. We find that the average dark count rate per SiPM is 4.3 MHz with a standard deviation of 1.5 MHz among devices. The analysis method we employ to measure internal optical crosstalk also naturally yields the mean and width of the single-electron pulse height. Here, we calculate separate contributions to the width of the single-electron pulse-height from electronic noise and avalanche fluctuations. We demonstrate a timing resolution for a single-photon pulse to be (128 ± 4) ps. Finally, coincidence analysis is employed to measure external (pixel-to-pixel) optical crosstalk. We present a map of the average external crosstalk probability between 2×4 groups of SiPMs, as well as the in-situ timing characteristics extracted from the coincidence analysis. Further work is needed to characterize the performance of the camera at reconstructing single- and double-site interactions, as well as image reconstruction.

47 OTHER INSTRUMENTATION↗

Batch VUV4 characterization for the SBC-LAr10 scintillating bubble chamber

The Scintillating Bubble Chamber (SBC) collaboration purchased 32 Hamamatsu VUV4 silicon photomultipliers (SiPMs) for use in SBC-LAr10, a bubble chamber containing 10 kg of liquid argon. A dark-count characterization technique, which avoids the use of a single-photon source, was used at two temperatures to measure the VUV4 SiPMs breakdown voltage (V BD ), the SiPM gain (g SiPM ), the rate of change of g SiPM with respect to voltage (m), the dark count rate (DCR), and the probability of a correlated avalanche (P CA ) as well as the temperature coefficients of these parameters. A Peltier-based chilled vacuum chamber was developed at Queen's University to cool down the Quads to 233.15 ± 0.2 K and 255.15 ± 0.2 K with average stability of ±20 mK. An analysis framework was developed to estimate V BD to tens of mV precision and DCR close to Poissonian error. The temperature dependence of V BD was found to be 56 ± 2 mV K -1 , and m on average across all Quads was found to be (459 ± 3(stat.)±23(sys.))× 10 3 e- PE -1 V -1 . The average DCR temperature coefficient was estimated to be 0.099 ± 0.008 K -1 corresponding to a reduction factor of 7 for every 20 K drop in temperature. The average temperature dependence of P CA was estimated to be 4000 ± 1000 ppm K -1 . P CA estimated from the average across all SiPMs is a better estimator than the P CA calculated from individual SiPMs, for all of the other parameters, the opposite is true. All the estimated parameters were measured to the precision required for SBC-LAr10, and the Quads will be used in conditions to optimize the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ETROC1: the first full chain precision timing prototype ASIC for CMS MTD endcap timing layer upgrade

We present the design and characterization of the first fullchain precision timing prototype ASIC, named ETL Readout Chipversion 1 (ETROC1) for the CMS MTD endcap timing layer (ETL)upgrade. The ETL utilizes Low Gain Avalanche Diode (LGAD) sensors todetect charged particles, with the goal to achieve a time resolutionof 40–50 ps per hit, and 30–40 ps per track with hits from twodetector layers. The ETROC1 is composed of a 5 × 5 pixelarray and peripheral circuits. The pixel array includes a4 × 4 active pixel array with an H-tree shaped networkdelivering clock and charge injection signals. Each active pixel iscomposed of various components, including a bump pad, a chargeinjection circuit, a pre-amplifier, a discriminator, adigital-to-analog converter, and a time-to-digital converter. Thesecomponents play essential roles as the front-end link in processingLGAD signals and measuring timing-related information. Theperipheral circuits provide clock signals and readoutfunctionalities. The size of the ETROC1 chip is7 mm× 9 mm. ETROC1 has been fabricated in a 65 nmCMOS process, and extensively tested under stimuli of chargeinjection, infrared laser, and proton beam. The time resolution ofbump-bonded ETROC1 + LGAD chipsets reaches 42–46 ps per hit in thebeam test.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measured gain suppression in FBK LGADs with different active thicknesses

In recent years, the gain suppression mechanism has been studied for large localized charge deposits in Low-Gain Avalanche Detectors (LGADs). LGADs are a thin silicon detector with a highly doped gain layer that provides moderate internal signal amplification. Using the CENPA Tandem accelerator at the University of Washington, the response of LGADs with different thicknesses to MeV-range energy deposits from a proton beam were studied. Three LGAD prototypes of 50 μm, 100 μm, and 150 μm were characterized. The devices' gain was determined as a function of bias voltage, incidence beam angle, and proton energy. This study was conducted in the scope of the PIONEER experiment, an experiment proposed at the Paul Scherrer Institute to perform high-precision measurements of rare pion decays. LGADs are considered for the active target (ATAR), and energy linearity is an important property for particle ID capabilities.

Particle tracking detectors↗

Performance of an X-γ ray detection system based on a thick silicon LGAD

We present the performance of a X-γ ray detection systems based on a 300 µm thick silicon low-gain avalanche diode (LGAD) and of an equivalent Diode structure without the gain layer, read-out by a custom-made low-noise charge amplifier. For the LGAD structure, the multiplication gains M s from 10.2 to 19.3 are measured, and the Equivalent Noise Charge (ENC) components have been studied in detail. As expected, a significant reduction of the white and 1/f voltage series and dielectric ENC components is observed with increasing gain, shortening the optimum peaking time to τ = 0.4÷8 μs depending on the gain value, with respect to the standard diode, while the parallel ENC component increases proportionally to the gain up to M s = 15. Setting the gain M s = 12.7, a minimum ENC = 34.5 electrons r.m.s. (298 eV FWHM) at τ = 1 μs is found. However, the electronic noise, evaluated on the pulser FWHM, is found to only marginally contribute to the width of the spectral lines of a radioactive source, which are dominated instead by the statistical noise of the charge multiplication within the LGAD structure. The spectral lines' excess width is found to be proportional to the signal multiplication gain M s and increases with the energy of the photons. A minimum line width of 850 eV FWHM at 13.9 keV is measured at room temperature, τ = 2 μs and a gain M s = 10.2.

47 OTHER INSTRUMENTATION↗

Commissioning of an MPGD-based Drift Chamber for Heavy-ion Tracking in FRIB's Sweeper magnet system

A newly developed drift chamber equipped with an innovative hybrid Micro-Pattern Gaseous Detector based readout was commissioned at FRIB. The detector consists of a Multi-layer Thick Gas Electron Multiplier (M-THGEM) mounted over a high-granularity, position-sensitive readout board. Denoted as the Micro-Pattern Drift Chamber (MPDC), the new device is used to provide tracking capability as part of the detectors of the Sweeper magnet system for neutron-invariant-mass spectrometry at the Facility for Rare Isotope Beams (FRIB). The localization of impinging ions in a 30 × 30 cm 2 drift area is derived by processing the charge-avalanche distribution induced on the segmented readout board. The signals induced on the readout pads are processed by a compact, multi-channel Data Acquisition System (DAQ) based on the Scalable Readout System (SRS). To facilitate synchronization with other detector systems of the Sweeper magnet system, the SRS has been configured to accept an external trigger.

Gaseous detectors↗

Studying AC-LGAD strip sensors from laser and testbeam measurements

Here, this paper presents the setup assembled to characterize and measure the spatial and timing resolutions of AC-coupled Low Gain Avalanche Diodes (AC-LGADs), using a 1060 nm laser source to deposit initial charges with a defined calibration methodology. The results were compared to those obtained with a 120 GeV proton beam. Despite the differences in the charge deposition mechanism between the laser and proton beam, the spatial and temporal resolutions were found to be compatible between the two sources after calibration. With 4D tracking detectors expected to play a vital role in upcoming collider experiments, we foresee this work as a way to evaluate the performance of semiconductor sensors that can augment testbeam measurements and accelerate R&D efforts. Additionally, simulation studies using Silvaco TCAD and Weightfield2 were carried out to understand the various contributing factors to the total time resolution in AC-LGAD sensors, measured using the laser source.

FOS: Physical sciences↗

The sweeper spectrometer for neutron invariant-mass spectroscopy at FRIB

Neutron invariant-mass spectroscopy (NIMS) is a key technique for studying unbound and weakly bound nuclei at the limits of stability. At the Facility for Rare Isotope Beams (FRIB), such measurements are performed using the Sweeper spectrometer, a large-gap, high-rigidity dipole system coupled to the MoNA-LISA neutron detector arrays. To meet the demands imposed by higher beam energies (>130 MeV/u) and the broad cocktail-beam selection available at FRIB, the spectrometer has recently been upgraded to improve particle-identification and detection performance. Upstream of the reaction target, a plastic scintillator with Silicon photomultiplier (SiPM) readout provides the global trigger and time reference, two parallel plate avalanche counters (PPACs) track the trajectories of incoming beam particles, and a silicon PIN detector measures the energy loss, ΔE, for charge (Z) identification. After the Sweeper magnet, the trajectories of the reaction products are tracked by two micro-pattern drift chambers (MPDCs), their charge (Z) is identified by a Frisch-grid ionization chamber (FG-IC), and their mass-to-charge ratio (A/Q) is deduced by time-of-flight measurement using a fast plastic scintillator read out by an array of photomultiplier tubes (PMTs). The detection system also incorporates the Modular Neutron Array (MoNA) for neutron detection and the CAESium-iodide scintillator ARray (CAESAR) for high-efficiency γ-ray measurements to enable full kinematic reconstruction. Performance was evaluated using a cocktail beam around 37 Al accelerated at E ≈ 130 MeV/u during the first FRIB campaign, demonstrating the readiness of the upgraded system for future studies of nuclei at and beyond the neutron drip line.

Particle identification methods↗

Computational prediction of dielectric breakdown strength of a transformer paper in oil with uncertainty quantification

The determination of the dielectric breakdown strengths of microstructurally heterogeneous materials has been a primarily experimental endeavor. We report the development of a microstructure-level model for computationally predicting the breakdown strength and analyzing the interactions between electromagnetic pulses (EMP) and the constituents in a composite of cellulose-based paper and mineral oil found in electrical transformers. The model allows explicit simulation of the material breakdown process by tracking the transition of dielectric constituents from non-conductive to conductive states. The focus is on the electric fields induced in the materials and the overall conditions for dielectric breakdown (defined as the onset of avalanche) caused by the electric field induced in the composite. Responses to three distinct pulse shapes, i.e., Steep Front (SF), Lightning (L), and AC with spectra spanning 60–9 × 105 Hz are considered. It is found that the breakdown strength of the material is significantly affected by microstructure heterogeneities, the spatial variations of the constituent properties, and the pulse shapes. A probabilistic characterization of the breakdown strength is computationally obtained and compared with experimental measurements. Although one particular material is analyzed, the model and approach are applicable to other heterogeneous materials as well.

breakdowns↗

Cycle equivalence classes, orthogonal Weingarten calculus, and the mean field theory of memristive systems

Abstract It has been recently noted that for a class of dynamical systems with explicit conservation laws represented via projector operators, the dynamics can be understood in terms of lower dimensional equations. This is the case, for instance, of memristive circuits. Memristive systems are important classes of devices with wide-ranging applications in electronic circuits, artificial neural networks, and memory storage. We show that such mean-field theories can emerge from averages over the group of orthogonal matrices, interpreted as cycle-preserving transformations applied to the projector operator describing Kirchhoff’s laws. Our results provide insights into the fundamental principles underlying the behavior of resistive and memristive circuits and highlight the importance of conservation laws for their mean-field theories. In addition, we argue that our results shed light on the nature of the critical avalanches observed in quasi-two-dimensional nanowires as boundary phenomena.

97 MATHEMATICS AND COMPUTING↗

Statistical relationships across epigenomes using large-scale hierarchical clustering

Recent advances in genomics and sequencing platforms have revolutionized our ability to create immense data sets, particularly for studying epigenetic regulation of gene expression. However, the avalanche of epigenomic data is difficult to parse for biological interpretation given nonlinear complex patterns and relationships. This attractive challenge in epigenomic data lends itself to machine learning for discerning infectivity and susceptibility. In this study, we explore over 3000 epigenomes of uninfected individuals and provide a framework to characterize the relationships among epigenetic modifiers, their modifiers, genetic loci, and specific immune cell types across all chromosomes using hierarchical clustering. Hierarchical clustering of epigenomic data revealed consistent epigenetic patterns across chromosomes, demonstrating that variation due to epigenetic modifiers is greater than variation between cell types. Gene Ontology and KEGG pathway analyses indicated significant enrichment of genes involved in chromatin remodeling, mRNA splicing, immune responses, and the regulation of microRNAs and snoRNAs. Epigenetic modifiers frequently formed biologically relevant clusters, including the cohesin complex, RNA Polymerase II transcription factors, and PRC2 complex members. These clustering behaviors remained consistent across all chromosomes, supported by entropy analysis and high Adjusted Rand Index scores, indicating robust cross-chromosomal similarity. Co-occurrence analysis further revealed specific sets of modifiers that consistently appeared together within clusters, reflecting shared biological functions and interactions. Validation using another dataset confirmed the reproducibility of these clustering patterns and modifier co-occurrence relationships, underscoring the reliability and generalizability of the methodology.

97 MATHEMATICS AND COMPUTING↗

Lepton flavor violation by three units

The conservation of lepton flavor is a prediction of the Standard Model and is still an excellent approximate symmetry despite our observation of neutrino oscillations. Lepton flavor violation by one or two units has been discussed for decades, with several dedicated experiments exploring the vast model landscape but no discoveries so far. Here, we explore operators and processes that violate at least one lepton flavor by three units and identify testable signatures. In the Standard Model effective field theory, such operators already arise at mass dimension 7 and can be tested through their contributions to Michel parameters in leptonic decays. True neutrinoless charged-lepton flavor violation arises at mass dimension 10 and can realistically only be seen in the tau decay channels 𝜏 → $𝑒⁢𝑒⁢𝑒⁢\bar{𝜇}⁢\bar{𝜇}$ or 𝜏 → $𝜇⁢𝜇⁢𝜇\bar{𝑒}\bar{𝑒}$, for example in Belle II. Testable rates for these tau decays require light new particles and subsequently predict an avalanche of remarkably clean but so-far unconstrained collider signatures.

Feynman diagrams↗

Radiation-Induced Dark Counts for Silicon Single-Photon Detectors in Space

Single-photon detectors operating on satellites for use in a quantum communications network can incur large dark-count-rate increases from the natural radiation environment of space. Displacement damage to the material lattice of a detector from the ionizing radiation can result in a permanent dark-count increase in the detector. In this work, we analyze the radiation-induced dark-count rate of a silicon single-photon avalanche diode onboard a satellite at different orbiting altitudes, as well as, the additional radiation from a nuclear-disturbed environment caused by a high-altitude nuclear explosion. For detectors on low Earth orbit satellites, protons are the biggest source of radiation damage and are best mitigated by choosing an orbit that minimizes exposure when passing through the South Atlantic Anomaly and Polar Cusps. Detectors on medium Earth orbit and geostationary orbit satellites, if shielded by more than 10 mm of aluminum, provide the best platform in terms of the least amount of radiation damage to the detectors. In the event of a high-altitude nuclear explosion, the artificial radiation belts produced by the explosion will cause too much damage to silicon single-photon detectors on low Earth orbit satellites and render them unfit for quantum communications in less than a day. Higher orbit satellites will only suffer minor dark-count-rate increases from the artificial radiation belts.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Remote detection of radioactive material using a short-pulse CO 2 laser

Detection of radioactive material at distances greater than the radiated particle range is an important goal with applications in areas such as national defense and disaster response. Here, we demonstrate avalanche-breakdown-based remote detection of a 3.6 mCi α-particle source at a standoff distance of 10 m, using 70 ps, long-wave infrared (λ = 9.2 µm) CO 2 laser pulses. This is ∼10 times longer than our previous results using a mid-IR laser. The primary detection method is direct backscatter from microplasmas generated in the laser focal volume. The backscatter signal is amplified as it propagates back through the CO 2 laser chain, enhancing sensitivity by >100 times. Here we also characterize breakdown plasmas with fluorescence imaging, and present a simple model to estimate backscattered signals as a function of the seed density profile in the laser focal volume. All of this is achieved with a relatively long-drive laser focal geometry (f/200) that is readily scalable to >100 m.

43 PARTICLE ACCELERATORS↗

Many-body localization near the critical point

Here, we examine the many-body localization (MBL) phase transition in one-dimensional quantum systems with quenched randomness and short-range interactions. Following recent works, we use a strong-randomness renormalization group (RG) approach where the phase transition is due to the so-called avalanche instability of the MBL phase. We show that the critical behavior can be determined analytically within this RG. On a rough qualitative level the RG flow near the critical fixed point is similar to the Kosterlitz-Thouless (KT) flow as previously shown, but there are important differences in the critical behavior. Thus, we show that this MBL transition is in a universality class that is different from KT. The divergence of the correlation length corresponds to critical exponent $\textit{ν → ∞}$, but the divergence is weaker than for the KT transition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of the U 235 ( n , f ) prompt fission neutron spectrum from 10 keV to 10 MeV induced by neutrons of energy from 1 MeV to 20 MeV

The characterization of fission-driven nuclear systems primarily relies on calculations of neutron-induced chain reactions, and these calculations require evaluated nuclear data as input. Calculation accuracy heavily depends on input nuclear data evaluation accuracy, and thus high precision on the experimental input to the nuclear data evaluation is essential for fundamental quantities like the energy spectrum of neutrons emitted from neutron-induced fission (i.e., the prompt fission neutron spectrum, PFNS). Despite decades of measurement efforts, prior to the measurements described in this work there were only three literature data sets for the 235 U(n,f) PFNS at incident neutron energies above 1.0 MeV considered reliable for inclusion in nuclear data evaluations and no reliable data sets above 3.0 MeV incident neutron energy. In this work we report on new measurements of the 235 U(n,f) PFNS spanning a grid of 1.0–20.0 MeV in incident neutron energy and 0.01–10.0 MeV in outgoing (PFNS) neutron energy. These measurements were carried out at the Weapons Neutron Research facility at the Los Alamos Neutron Science Center and used a multifoil parallel-plate avalanche counter target with both a Li-glass and a liquid scintillator detector array in separate experiments to span the quoted outgoing neutron energy ranges. The PFNS results are shown in terms of the energy spectra themselves as well as the average PFNS energy $(\langle{E}\rangle)$ and ratios of $\langle{E}\rangle$ at forward and backward angles. Here, the results are compared with literature data and selected nuclear data evaluations. Generally, the data agree with the ENDF/B-VIII.0 evaluation below 5.0-MeV incident neutron energy and more closely with the JEFF-3.3 evaluation above 5.0 MeV, though no evaluations considered for comparison in this work agree with the data across all of the incident and outgoing neutron energies shown, especially in regions where the third-chance fission process becomes available. Additionally, we show a ratio of the present PFNS results for 235 U(n, f) with a recent and highly correlated experiment to measure the 239 Pu(n, f) PFNS at the same experimental facility and with nearly identical equipment and analysis procedures. Many observations reported in this work are the first of their kind and represent significant advancements for knowledge of the 235 U(n, f) PFNS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Time projection chamber for GADGET II

The established Gaseous Detector with Germanium Tagging (GADGET) detection system is used to measure weak, low-energy 𝛽-delayed proton decays. It consists of the Gaseous Proton Detector equipped with a MICROMEGAS (MM) readout to detect protons and other charged particles calorimetrically, surrounded by the Segmented Germanium Array (SeGA) for high-resolution detection of prompt 𝛾 rays. To upgrade GADGET's Proton Detector to operate as a compact time projection chamber (TPC) for the detection, three-dimensional imaging and identification of low-energy 𝛽-delayed single- and multiparticle emissions mainly of interest to astrophysical studies. A new high granularity MM board with 1024 pads has been designed, fabricated, installed, and tested. A high-density data acquisition system based on generic electronics for TPCs (GET) has been installed and optimized to record and process the gas avalanche signals collected on the readout pads. The TPC's performance has been tested using a 220 Rn 𝛼-particle source and cosmic-ray muons. In addition, decay events in the TPC have been simulated by adapting the attpcroot data analysis framework. Furthermore, a novel application of two-dimensional convolutional neural networks for GADGET II event classification is introduced. The optimization of data throughput is also addressed. The GADGET II TPC is capable of detecting and identifying 𝛼 particles as well as measuring their track direction, range, and energy. The extracted energy resolution of the GADGET II TPC using P10 gas is about 5.4% at 6.288 MeV ( 220 Rn 𝛼 events), computed using charge integration. Based on a systematic simulation study, we estimated the detection efficiency of the GADGET II TPC for protons and 𝛼 particles, respectively. It has also been demonstrated that the GADGET II TPC is capable of tracking minimum-ionizing particles (i.e., cosmic-ray muons). From these measurements, the electron drift velocity was measured under typical operating conditions. In addition to being one of the first generation of micropattern gaseous detectors (MPGDs) to utilize a resistive anode applied to low-energy nuclear physics, the GADGET II TPC will also be the first TPC surrounded by a high-efficiency array of high-purity germanium 𝛾-ray detectors. As a result, the TPC of GADGET II has been designed, fabricated, and tested and is ready for operation at the Facility for Rare Isotope Beams for radioactive-beam-line experiments.