Search NASA⌕ Search

SEARCH · Search NASA

Results for “battery energy storage system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Interactive multiscale modeling to bridge atomic properties and electrochemical performance in Li-CO 2 battery design

Li-CO 2 batteries are promising energy storage systems due to their high theoretical energy density and CO 2 fixation capability, relying on reversible Li 2 CO 3 /C formation during discharge/charge cycles. Here, we present a multiscale modeling framework integrating Density Functional Theory (DFT), Ab-Initio Molecular Dynamics (AIMD), classical Molecular Dynamics (MD), and Finite Element Analysis (FEA) to investigate atomic and cell-level properties. The considered Li-CO 2 battery consists of a lithium metal anode, an ionic liquid electrolyte, and a carbon cloth cathode with Sb 0.67 Bi 1.33 Te 3 catalyst. DFT and AIMD determined the electrical conductivities of Sb 0.67 Bi 1.33 Te 3 and Li 2 CO 3 using the Kubo–Greenwood formalism and studied the CO 2 reduction mechanism on the cathode catalyst. MD simulations calculated the CO 2 diffusion coefficient, Li + transference number, ionic conductivity, and Li + solvation structure. The FEA model, parameterized with atomistic simulation data, reproduced the available experimental voltage–capacity profile at 1 mA/cm 2 and revealed spatio-temporal variations in Li 2 CO 3 /C deposition, porosity, and CO 2 concentration dependence on discharge rates in the cathode. Accordingly, Li 2 CO 3 can form large and thin film deposits, leading to dispersed and local porosity changes at 0.1 mA/cm 2 and 1 mA/cm 2 , respectively. The capacity decreases exponentially from 81,570 mAh/g at 0.1 mA/cm 2 to 6200 mAh/g at 1 mA/cm 2 , due to pore clogging from excessive discharge product deposition that limits CO 2 transport to the cathode interior. Therefore, the performance of Li-CO 2 batteries can be improved by enhancing CO 2 transport, regulating Li 2 CO 3 deposition, and optimizing cathode architecture.

Battery performance↗

Comparing the economic performance of ice storage and batteries for buildings with on-site PV through model predictive control and optimal sizing

Integrating renewable energy and energy storage systems provides a way of operating the electrical grid system more energy efficiently and stably. Thermal storage and batteries are the most common devices for integration. However, it is not clear which integrated storage system performs better in terms of overall economics. Ice storage has low initial and maintenance costs, but there is an efficiency penalty for charging of storage and it can only shift electrical loads associated with building cooling requirements. A battery's round-trip efficiency, on the contrary, is quite consistent and batteries can be used to shift both HVAC and non-HVAC loads. However, batteries have greater initial costs and a shorter life. Finally, this research presents a tool, using model predictive control and optimal sizing, and provides a case study for comparing life-cycle economics of battery and ice storage systems for commercial buildings that have chillers for cooling and an on-site photovoltaic system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chloride electrolyte enabled practical zinc metal battery with a near-unity Coulombic efficiency

Rechargeable aqueous zinc batteries are finding their niche in stationary storage applications where safety, cost, scalability and carbon footprint matter most. However, harnessing this reversible two-electron redox chemistry is plagued by major technical issues, notably hydrogen evolution reaction (HER) at the zinc surface, whose impacts are often not revealed under typical measurement conditions. Here we report a concentrated electrolyte design that eliminates this parasitic reaction and enables a Coulombic efficiency (CE) of 99.95% for Zn plating/stripping measured at a low current density of 0.2 mA cm -2 . With extra chloride salts and dimethyl carbonate in concentrated ZnCl 2 electrolyte, the hybrid electrolyte with a unique chemical environment features low Hammett acidity and facilitates the in situ formation of a dual-layered solid electrolyte interphase, protecting zinc anodes from HER and dendrite growth. Benefiting from the near-unity CE, the pouch cell with a VOPO 4 ·2H 2 O cathode sustains 500 deep cycles without swelling or leaking and delivers an energy density of 100 Wh kg -1 under practical conditions. Finally, our work represents a critical step forward in accelerating the market adoption of zinc batteries as an energy storage system with higher sustainability.

25 ENERGY STORAGE↗

Anion sublattice design enables superionic conductivity in crystalline oxyhalides

Solid-state batteries are attractive energy storage systems as a result of their inherent safety, but their development hinges on advanced solid-state electrolytes (SSEs). Most SSEs remain largely confined to single-anion systems (e.g., sulfides, oxides, halides, and polymers). Through mixed-anion design strategy, we develop crystalline Li 3 Ta 3 O 4 Cl 10 (LTOC) and its derivatives with excellent ionic conductivities (up to 13.7 millisiemens per centimeter at 25°C) and electrochemical stability. The LTOC structure features mixed-anion spiral chains, consisting of corner-shared oxygen and terminal chlorine atoms, which induces continuous “tetrahedron-tetrahedron” Li-ion migration pathways with low energy barriers. Additionally, LTOC demonstrates holistic cathode compatibility, enabling solid-state batteries operation at 4.9 volts versus Li/Li + and low temperature, down to −50°C. In conclusion, these findings describe a promising class of superionic conductors for high-performance solid-state batteries.

Zhao, Feipeng [Western University, London, ON (Can↗

Energy management systems for forecasted demand error compensation using hybrid energy storage system in nanogrid

This paper proposes an energy management system (EMS) for nanogrids to balance the power supply and forecasted demand in consideration of forecasting errors arising from high instantaneous demand. The proposed EMS employs a power-balancing optimization process for forecasted demand and a reference power modulation strategy for forecasting errors. This power-balancing optimization utilizes nanogrid sources, such as photovoltaics, fuel cells, and batteries, to meet forecasted demand and a supercapacitor charging process to overcome issues with a low energy density. The proposed reference power modulation strategy is utilized to allocate power from a hybrid energy storage system consisting of a battery and supercapacitor in order to compensate for forecasting errors. In addition, this proposed strategy considers battery and supercapacitor constraints such as the power changing rate and total power limitations. Further, the power-balancing optimization process also operates at faster sampling rate than the reference power modulation process in order to improve the computational efficiency. The performance of the proposed EMS is evaluated using real data obtained from the Korea Electric Power Exchange.

25 ENERGY STORAGE↗

Field-Aging Test Bed for Behind-the-Meter PV + Energy Storage

Small DC-coupled battery test systems are deployed at the National Renewable Energy Laboratory to evaluate capacity fade models and report on performance parameters such as round-trip efficiency under indoor and outdoor deployment scenarios. Initial commercial battery products include LG Chem RESU lithium-ion (Li-ion) and Avalon vanadium redox flow batteries. Adapting indoor lab-scale test methods to outdoor systems has challenges, including maintaining constant temperature and fully controlling batteries through standard discharge curves. Initial measurements show the Li-ion battery systems performing within expectations, near 85% round-trip efficiency. Initial lifetime modeling and measurements indicate that battery capacity could degrade by 20%-35% over 10 years at current rates.

14 SOLAR ENERGY↗

Analysis of AC-DC Converters for Grid-tied High Temperature Steam Electrolysis Systems

Grid-tied HTSE systems have the prospects to produce clean hydrogen enabling power and broad energy systems decarbonization. Most commercially available power electronic converter systems (PECS) are designed for batteries, solar PVs, wind, and other well-established renewable energy resources. Standards (such as IEEE 1547, UL 1741, CA Rule-21, HI Rule-14) exist for PECS used for renewable energy systems such as battery storage and solar PVs. However, those that consider the dynamic behavior of HTSEs and that can be used for large-scale H2 systems are yet to be developed. This paper investigates the performance of these PECS for the HTSE application that are set up at the Idaho National Laboratory for hydrogen production testing, research and development. In particular, the performance analysis of two grid-tied PECS (A and B) is conducted for a 100 kW solid oxide HTSE system. System A consists of 6 units of 30kW MOSFET-switched bidirectional AC-DC rectifier while system B has a single unit of 150kW thyristor-switched ACDC rectifier. Both systems are connected to the HTSE stacks via a DC-DC converter. Different operational conditions of the HTSE system are tested to analyze the dynamic response of the HTSE’s PECS. The experimental results show the need to develop advanced control strategies for PECS that incorporates the dynamics of HTSE systems for improved performance.

08 - HYDROGEN↗

Analysis of AC-DC Converters for Grid-tied High Temperature Steam Electrolysis Systems

Grid-tied HTSE systems have the prospects to produce clean hydrogen enabling power and broad energy systems decarbonization. Most commercially available power electronic converter systems (PECS) are designed for batteries, solar PVs, wind, and other well-established renewable energy resources. Standards (such as IEEE 1547, UL 1741, CA Rule-21, HI Rule14) exist for PECS used for renewable energy systems such as battery storage and solar PVs. However, those that consider the dynamic behavior of HTSEs and that can be used for large-scale H2 systems are yet to be developed. This paper investigates the performance of these PECS for the HTSE application that are set up at the Idaho National Laboratory for hydrogen production testing, research and development. In particular, the performance analysis of two grid-tied PECS (A and B) is conducted for a 100 kW solid oxide HTSE system. System A consists of 6 units of 30kW MOSFET-switched bidirectional AC-DC rectifier while system B has a single unit of 150kW thyristor-switched AC-DC rectifier. Both systems are connected to the HTSE stacks via a DC-DC converter. Different operational conditions of the HTSE system are tested to analyze the dynamic response of the HTSE’s PECS. The experimental results show the need to develop advanced control strategies for PECS that incorporates the dynamics of HTSE systems for improved performance.

High temperature steam electrolysis↗

Electrification Options for Multi-Family Water Heating in Cold Climates - Final Report

In multi-family buildings, large water storage tanks in centralized domestic hot water (DHW) systems can serve as thermal energy storage (TES) batteries to mitigate grid impact. These systems offer demand shift and efficiency benefits, significantly reducing peak power consumption, particularly in cold climates. This study evaluates the load-shifting benefits of a centralized heat pump water heater (HPWH) system equipped with a CO2 heat pump in multi-family buildings through simulation. The heat pump system and water storage tank are sized using design-day sizing. A finite-element-based stratified tank model and CO2 heat pump performance map from a commercial DHW product are used. Annual simulations are conducted to assess the benefits of the centralized DHW system for energy efficiency improvements, load shifting, and emission reductions. These simulations incorporate utility tariffs and marginal grid emission data from Los Angeles and Chicago. In Los Angeles, using a water tank as a thermal battery achieves 7.4% utility cost savings and 10.2% emission reduction. In Chicago, compared to HPWH conventional operation without preheating, TES-enabled central HPWH provides 15% utility cost savings and 13% emission reduction. The case study demonstrates that the demand reduction potential of central CO2 HPWHs is significant in cold climate regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Catalyzing deep decarbonization with federated battery diagnosis and prognosis for better data management in energy storage systems

Industrial data analytics methods play a central role in improving energy storage performance and efficiency, impacting the future of electrified transportation and renewable electricity generation. However, significant challenges hinder the large-scale deployment of batteries. Conventional methods rely on centralized collection and processing of fleet-level data, leading to database size issues and privacy concerns due to potential data breaches. To enable scalable deployment of battery management systems, this article proposes a federated battery diagnosis and prognosis model, which distributes the processing of battery standard current-voltage-time-usage data in a privacy-preserving manner. Instead of transferring the raw data, this approach communicates only the locally processed parameters, thus reducing communication load and preserving data confidentiality. The federated model offers a paradigm shift in battery health management through privacy-preserving distributed methods for battery data processing and lifetime prediction, ensuring the reliable and sustainable deployment of lithium-ion batteries in a rapidly evolving world.

asset health management↗

Multifaceted effects of ring fusion on the stability of charged dialkoxyarene redoxmers

Due to their almost unlimited scalability, redox flow batteries can make versatile and affordable energy storage systems. Redox active materials (redoxmers) in these batteries largely define their electrochemical performance, including the life span of the battery that depends on the stability of charged redoxmers. Here, in this study, we examine the effects of expanding the pi-system in the arene rings on the chemical stability of dialkoxyarene redoxmers that are used to store positive charge in RFBs. When 1,4-dimethoxybenzene is pi-extended to 1,4 dimethoxynaphthalene, a lower redox potential, improved kinetic stability, and longer cycling life are observed. However, when an additional ring is fused to make 9,10-dimethoxyanthracene, the radical cation undergoes rapid O -dealkylation possibly due to increased steric strain that drives methoxy out of the arene plane thus breaking the pi-conjugation with O 2p orbitals. On the other hand, the planar structure of 1,4-dimethoxynaphthalene may facilitate second -order reactions of radical cations leading to their neutralization in the bulk. Our study suggests that extending the pi-system changes reactivity in multiple (sometimes, opposite) ways, so lowering the oxidation potential through pi-conjugation to improve redoxmer stability should be pursued with caution.

25 ENERGY STORAGE↗

Design-Point Techno-Economics of Brayton Cycle PTES for Combined Heat and Power

Pumped thermal energy storage (PTES) systems are grid batteries that use heat pumps to create both hot and cold thermal energy stores when there is excess electricity and then use a power cycle to convert the thermal energy into electricity when there is demand for electricity. In normal operation, Joule–Brayton PTES discharges low-grade heat at temperatures useful for thermal energy consumers like district and industrial heating. Furthermore, PTES designs, like conventional combined heat and power (CHP) technology, can be modified to sacrifice some round-trip efficiency (RTE) to increase the temperature of heat rejection. Here, this paper uses design-point performance and cost models that provide a detailed understanding of the efficiency and cost tradeoffs of rejecting heat at various temperatures in ideal-gas Brayton PTES configurations. First, we keep the heat rejection in its nominal location in the PTES system: in the discharge cycle after the low-pressure exit of the recuperator before the cold-storage heat exchanger. Next, we move the heat rejection to the discharge turbine exit. We define design-point metrics that isolate both the cost and performance penalty associated with the hotter heat rejection and attribute it exclusively to the heat economic metrics. Finally, we estimate the performance of electric heater technology to generate heat at equivalent temperatures. We find that the levelized cost of heat (LCOH), including the cost of thermal energy storage (TES) buffering the PTES and heat off-taker, compares favorably versus electric technologies and is less than the cost of natural gas for low temperature scenarios and competitive with the cost of natural gas in some regions of the contiguous U.S. in high temperature scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design-Point Techno-Economics of Brayton Cycle PTES for Combined Heat and Power

Pumped thermal energy storage (PTES) systems are grid batteries that use heat pumps to create both hot and cold thermal energy stores when there is excess electricity and then use a power cycle to convert the thermal energy into electricity when there is demand for electricity. In normal operation, Joule-Brayton PTES discharges low-grade heat at temperatures useful for thermal energy consumers like district and industrial heating. Furthermore, PTES designs, like conventional combined heat and power (CHP) technology, can be modified to sacrifice some round-trip efficiency RTE to increase the temperature of heat rejection. This paper uses design-point performance and cost models that provide a detailed understanding of the efficiency and cost trade-offs of rejecting heat at various temperatures in ideal-gas Brayton PTES configurations. First, we keep the heat rejection in its nominal location in the PTES system: in the discharge cycle after the low-pressure exit of the recuperator before the cold-storage heat exchanger. Next, we move the heat rejection to the discharge turbine exit. We define design-point metrics that isolate both the cost and performance penalty associated with the hotter heat rejection and attribute it exclusively to the heat economic metrics. Finally, we estimate the performance of electric heater technology to generate heat at equivalent temperatures. We find that the levelized cost of heat, including the cost of thermal energy storage (TES) buffering the PTES and heat off-taker, compares favorable versus electric technologies and is less than the cost of natural gas for low temperature scenarios and competitive with the cost of natural gas in some regions of the contiguous United States in high temperature scenarios.

CHP↗

Field Verification of Grid-Forming Inverter-Based Power Plant Performance for Transmission System Reliability

This report describes some examples of the operation of two grid-forming (GFM) inverter-based photovoltaic-battery hybrid power plants connected to the electric system of the island of Kauai in Hawaii. Both plants are photovoltaic power plants with battery energy storage and are connected to the networked transmission system operated by Kauai Island Utility Cooperative (KIUC), along with several other power plants including an oil-fired plant, diesel generators, small hydroelectric plants, a biofuel plant, and several other photovoltaic plants.

14 SOLAR ENERGY↗

Interfaces in all solid state Li-metal batteries: A review on instabilities, stabilization strategies, and scalability

With technological advancements in electrochemical energy storage systems increasing at a spectacular rate, batteries equipped with a lithium anode hold the key towards unlocking high energy densities. While lithium-ion batteries with layered anodes (e.g. graphite) and liquid organic electrolytes have been ubiquitous in portable electronics, electric vehicles, and grid applications, all solid-state batteries that use the combination of a lithium anode and a solid-state electrolyte (SSE) will further advance the present technology. The underlying challenge that limits the successful development of all solid-state batteries (ASSBs) is dictated largely by the highly reactive interfaces at the anode/SSE and the cathode/SSE interface. In this comprehensive review, we present an overview of the following: (i) characterization of the electrode/SSE interface via multimodal characterization, which include X-ray-, electron-, neutron-, optical-, and computation-based methods: (ii) parasitic reactions that occur from chemical, mechanical or electrochemical instabilities and interfacial engineering strategies for improving the stability of these interfaces classified by the class of inorganic SSEs (sulfide-, NASICON-, and garnet-type SSEs); (iii) laboratory-to-industry scale processing perspectives of SSEs; (iv) scalability and manufacturing aspects of current interfacial strategies; and (v) the prospects of all ASSBs within the context of extreme fast charging capability. Here, this review seeks to highlight key efforts in the field of ASSBs, by focusing particularly on stabilizing the electrode/SSE interfaces, which will help to bridge fundamental studies to technological relevance.

25 ENERGY STORAGE↗

Optimal, Reliable Building-Integrated Energy Storage (Cooperative Research and Development Final Report)

The team will advance the commercial readiness of behind-the-meter (BTM) energy storage (ES) systems by employing health-conscious controls that guarantee lifetime and optimize the ES system's value stream when integrated with onsite renewable energy generation. Specifically, the team will develop ES controls that increase the net present value (NPV) of photovoltaics (PV) by 50% in markets where net-metering policies are being replaced by variable electricity pricing structures. The team will also reduce the risk of achieving a 10-year ES warranty lifetime by at least one order of magnitude. The successful two-year project will develop the controls and system enabling Eaton to commercialize the technology by 2021. The developments achieved through this project may enable wide scale adoption of stationary energy storage benefitting the public.

25 ENERGY STORAGE↗