Search NASA⌕ Search

SEARCH · Search NASA

Results for “battery management system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

405 records · Page 23

Comprehensive assessment of deep reinforcement learning approaches for economic dispatch in nuclear-driven microgrids

As the electrical grid integrates more variable renewable energy sources such as wind and solar, the demand for distributed and flexible systems to address this increased variability becomes critical. Nuclear-driven microgrids provide a promising solution by offering stable generation to complement intermittent renewables, ensuring grid reliability and operating efficiency. This paper proposes a recurrent deep reinforcement learning framework for optimal economic dispatch in a nuclear-powered microgrid integrating renewable energy sources, small modular reactors, battery storage systems, and balance-of-plant dynamics. A three-agent control architecture is developed, where demand and renewable energy agents act as forecasters, and a reinforcement learning-based dispatch agent performs real-time energy allocation. A nonlinear programming formulation is first used to generate an optimal baseline for benchmarking. The proposed dispatch controller, based on Proximal Policy Optimization enhanced with Long Short-Term Memory networks, exploits temporal correlations in system dynamics by taking advantage of the time series used as inputs to improve policy robustness under uncertainty. Comparative analysis against established deep reinforcement learning methods, including Proximal Policy Optimization with a feedforward architecture, Soft Actor-Critic, and Twin Delayed Deep Deterministic Policy Gradient, demonstrates superior performance. Numerical results indicate that the proposed controller achieves a 0.39% cost reduction relative to the nonlinear programming benchmark and outperforms other learning-based methods by generating additional revenue of up to 0.35%. All reinforcement learning controllers compute dispatch actions in less than 0.3 s, resulting in a computational speedup of more than three orders of magnitude over the nonlinear programming baseline. The findings of this paper highlight their applicability for real-time operation and control in nuclear-integrated microgrids under volatile operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Vulcan Test Platform: Demonstrating the Data Center as a Flexible Grid Asset

Explosive data center demand is outpacing grid infrastructure development. AI workloads and hyperscale cloud growth are creating unprecedented power requirements, while traditional grid expansion faces multi-year development timelines, regulatory hurdles, and decarbonization challenges. Sidewalk Infrastructure Partners recognized this impending crisis years ago and founded Verrus to develop an innovative solution: data centers that function as grid assets rather than passive loads. The Verrus approach integrates proprietary grid-aware controls with battery energy storage systems (BESS) in a medium-voltage architecture that delivers three critical capabilities: Fast-responding demand flexibility that can service requests from the utility within 10 seconds, Uninterrupted transition to islanded operation during grid disturbances, Continuous uptime assurance while maintaining all customer service level commitments Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), we validated these capabilities on Vulcan, a 70 MW utility-scale test platform powered by NREL's ARIES Virtual Emulation Environment. This deployment-ready technology has successfully demonstrated that Verrus data centers can deliver meaningful grid services while maintaining mission-critical reliability. This technical report outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can play a pivotal role in enhancing grid flexibility and reliability, without sacrificing service level guarantees.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Port of Los Angeles Zero- and Near-Zero-Emission Freight Facilities Shore to Store Project

The City of Los Angeles Harbor Department (Harbor Department, Port of Los Angeles) partnered with Equilon Enterprises LLC (d/b/a Shell Oil Products US) (Shell), Toyota Motor North America (Toyota), and Kenworth Truck Company (Kenworth) partnered with the Port of Hueneme, United Parcel Service, Total Transportation Services Inc., Southern Counties Express, Toyota Logistics Services, Air Liquide, National Renewable Energy Laboratory, Coalition For A Safe Environment, and the South Coast Air Quality Management District to introduce hydrogen fuel into the Southern California drayage truck market by demonstrating near-commercial heavy-duty hydrogen fuel cell electric trucks at and between freight facilities throughout the region, while continuing to lay the groundwork for battery-electric operations. The Shore to Store project built on project team experience to help realize our vision of zero-emission freight operations in the future. Ten Kenworth zero-emission Class 8 fuel cell electric trucks, integrated with Toyota’s fuel cell drive technology, were operated by United Parcel Service, Total Transportation Services Inc., Southern Counties Express, and Toyota Logistics Services in commercial service. The demonstration fleet fueled at the Shore to Store hydrogen fueling stations that were built in Ontario, California, and Wilmington, California. An additional station at the Port of Long Beach (Portal Station) was available for fueling the fleet. Portal Station was supported by grants from the California Energy Commission and South Coast Air Quality Management District and used as match funding for the Shore to Store project. The Port of Hueneme demonstrated two battery-electric yard tractors, and Toyota Logistics Services demonstrated two zero-emission forklifts at their warehouse facility, showcasing elements of the entire supply chain operating with zero emissions. This project showcased a snapshot of the zero-emission supply chain of the future, providing a model by which freight facilities can support zero-emission operations. The Shore to Store project: Demonstrated the technical feasibility of zero-emission hydrogen fueled Class 8 heavy-duty trucks and electric cargo handling equipment in rigorous goods movement operation throughout the Southern California region. Cumulatively completed 59,212 miles of zero-emission operation, with 21,650 miles driven in-service with the fleets, using hydrogen fuel cell electric Class 8 heavy-duty trucks. Operated zero-emission yard tractors for a total of 2,749.6 hours. Created direct localized emission reductions in designated disadvantaged communities, including those in zip codes 90220, 90247, 90248, 90731, 90744, 90802, and 91761. For the 59,212 miles of zero-emission operation, reduced emissions by an estimated total of 15.5 kg NOX (0.163 g/km), 1.01 kg SOX (0.0106 g/km), and 304.8 metric tonnes of CO2e (3.2 kg/km) compared to diesel baseline vehicles including both tailpipe emissions and the emissions from producing the fuel sources.

08 HYDROGEN↗

SuperLab 2.0 Showcase: Connecting Five Labs to Tackle Grid Complexity and Unlock Unique Grid Asset Potential

SuperLab 2.0 (5-Lab Demo) is a collaborative, national-scale experiment showcasing the coordination of geographically distributed energy assets in real time. The demonstration integrates 25 physical and digital assets, spanning wind, PV, batteries, electrolyzers, DC fast chargers, microgrid controllers, building automation systems, small modular reactor (SMR), control centers, and gas turbines, across five DOE national laboratories-NLR, INL, NETL, LBNL, and SNL. These assets are unified using Energy Sciences Network (ESnet), a low-latency, high-performance U.S. Department of Energy's (DOE) network, and controlled via a centralized energy controller hosted at NLR's ARIES facility. The demonstration validates the ability to stress-test hybrid energy systems under dynamic scenarios to de-risk advanced control strategies for greater resilience and flexibility. SuperLab 2.0 (5-Lab Demo) showcased a major advancement in federated national laboratory collaboration, enabling real-time, cross-laboratory experimentation to coordinate geographically dispersed distributed energy resources (DERs) using various communication protocols and networks. SuperLab 2.0 (5-Lab Demo) built on previous demonstrations conducted between NLR-PNNL and NLR-INL connecting diverse assets including distant protection devices, a SMR simulator, and a high temperature electrolyzer (HTE). Previous demos were based on a single connection between two labs with minimal coordination challenges. The 5-Lab demo with a centralized controller, distributed testbeds across different geographical locations, and use of protocols-based communication represents a scenario closer to real-world grid operations that coordinate resources across a region to meet system needs. This experiment studied how local DER controllers interact with a centralized energy controller during normal and abnormal events to maintain reliability. The SuperLab team across the five labs implemented a notional power system model equivalent of transmission and distribution lines, represented by the data networks interconnecting the labs. Each lab continuously exchanged local parameters (such as P and Q) from its Hardware-In-Loop (CHIL) and Power Hardware-In-Loop (PHIL) assets through centralized energy controller at NLR, enabling real-time interaction and coordination across sites. By leveraging ESnet as the communication backbone, the team successfully operated the distributed assets as a unified power system, with each bus represented by a different laboratory. This setup mirrors how assets interact in real-world power systems across dispersed locations with various protocols and latencies. At each lab site, assets were operated using their own local controllers which were coordinated through an overarching operation and control layer of centralized energy controller, equivalent to how an energy management system (EMS) orchestrates assets across a regional or national grid. SuperLab's federated connectivity utilized a Digital Real-Time Simulators (DRTS)-type gateway to connect Controller Hardware-In-Loop (CHIL) and PHIL assets between labs. To enable this federated connection through ESnet, a deterministic network was established where latency variations were consistent. This consistency allowed the development of digital filters for the power system assets across CHIL and PHIL interfaces to avoid unstable and unreliable grid conditions. This report provides an overview of the cross-laboratory configuration and offers insights into interconnecting geographically distributed research assets to test them as if they were co-located. This experiment represents a step toward linking nine DOE national laboratories, enabling nation-wide simulations that can address utility-driven challenges with grid resilience, flexibility, and modernization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mitigating Data Center Impact on Grid Stability: A Coordinated Control Strategy Using Verrus StabiliGrid Architecture

Large data centers, which now represent a significant and growing share of the total U.S. grid load, can inadvertently destabilize the electrical grid when they disconnect simultaneously during brief voltage disturbances. The July 10, 2024, Eastern Interconnection incident, in which a sub-100-millisecond transmission fault triggered the cascading loss of approximately 1,500 MW of data center load, illustrates this vulnerability. While commercial battery energy storage systems (BESS) deployed in data centers provide device-level fault ride-through per IEEE 1547, they lack coordination with facility protection logic and uninterruptible power supplies (UPS), limiting their effectiveness as grid-stabilizing assets. This report presents the Verrus StabiliGrid architecture, a coordinated control framework that integrates BESS, UPS, and point-of-interconnection (POI) protection settings to enable data centers to ride through both undervoltage and overvoltage grid contingencies without disconnecting. The four-step strategy encompasses: (1) high-resolution power quality monitoring to detect the grid state during events such as undervoltage, overvoltage, underfrequency, and overfrequency; (2) POI protection settings that allow for extended ride-through and grid-connected operation during grid contingencies; (3) grid state-driven autonomous dispatch of assets to improve grid resilience by reducing power draw during undervoltage or absorbing more power during overvoltage events; and (4) coordinated post-recovery dispatch of data center assets to restore firm load to pre-contingency levels. Validated through controller-hardware-in-the-loop (C-HIL) simulations at the National Laboratory of the Rockies, results show grid import restoration to pre-fault levels within 100 milliseconds of voltage recovery. This work advances the ability of data centers to transition from passive, disturbance-sensitive loads to active participants in grid stability, a capability increasingly required by emerging NERC and ERCOT regulatory frameworks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Drive Cycles, Battery Pack Scaling, and Usage Considerations for Long-Haul and Regional-Haul Electric Trucks

Electrifying Class-8 heavy-duty trucks presents a promising opportunity to enhance energy efficiency and reduce freight transport costs. Battery electric trucks (BETs), once considered niche, are gaining traction due to advancements in battery technology and cost reductions. However, accurately predicting battery lifespan under realistic usage conditions remains a key challenge. Understanding battery failure mechanisms and their links to design, operation, and management is essential for developers and fleet operators. This study introduces a method to develop simplified, lab-testable dynamic stress test (DST) cycles for regional and long-haul Class-8 BETs, derived from real-world diesel truck usage. These DSTs enable benchmarking of battery technologies, identification of aging stressors, and optimization of battery design, life, and cost. The approach supports evaluation of key metrics such as levelized cost of driving and total cost of ownership, aiding fair comparisons and adoption decisions. We also propose feasible battery pack sizes that meet current driving demands with strategic charging, and a method to scale pack-level DSTs to cell-level cycles for lab-based testing. These tools facilitate tradeoff analysis across battery chemistries, pack sizing, and charging strategies, while offering means to get insights into battery aging under realistic conditions-ultimately supporting informed BET deployment decisions.

25 ENERGY STORAGE↗

Development of the Intelligent, Preventive Infrared (IR) Inspection System Housed in Hybrid Robotic Platforms

Robots and robotic systems that are designed for inspection, environmental study, and health and safety aid are becoming an increasing necessity. However, there is a number of challenges that accompany robots that are designed for these specific applications. These challenges include: navigating compact, enclosed spaces, travelling over multiple terrains and large obstacles, using the proper sensing and detection methods to assess an environment, and the use of lightweight and durable materials. The robotic platforms currently in development look at all of these challenges and attempt to overcome them. These designs specific use of hybrid robotic platforms, or platform that utilizes soft and rigid materials, allows for a more flexible platform and makes environments more navigable. To further improve the navigation of the platforms and environmental assessment, a novel infrared detection system is housed in the platforms to create a robot that can be used for the applications listed above and more. Objectives: Further develop two types of robotic platforms that utilize additive manufacturing, soft materials, and rigid materials. Continue the development of an intelligent and inhibitory infrared detection system based on an artificial intelligence (AI) algorithm. Continued study and fabrication of active soft materials designed for both sensing and actuation in hybrid robotic systems. Improve additive manufacturing fabrication to design rigid and semi-rigid components for hybrid robotic platforms. Transformable Wheel Robotic Platform: The chassis, wheels, tires and inspection system housing use different additive manufacturing techniques for fabrication. Continued work with additive manufacturing has lead to studies in metal-based printing and modular design and manufacturing. The new platform design with integrated electrical component printed. This will allow integration of the sensor housing onto the platform. Electrical components are being tested for battery life and performance. To improve this performance, such as integration of Lithium Polymer (LiPo) batteries. Snake Robotic Platform: The main focus of the development has centered around liquid-based soft actuators. That act on the principles of electrostatic and hydraulic actuation. A liquid dielectric sits between two compliant electrodes, contained by a flexible polymer shell. The electrodes and film gradually collapse toward each other from one corner of the electrode to the other. When the electrodes and film close together, a majority of the fluid is pushed into the area not covered by an electrode. A thin layer of the liquid dielectric remains between the electrode. The actuators will be stacked to cause large displacement, and move the linkages. The chassis of this platform uses purely additively manufactured linkages. Intelligent, Preventive IR Inspection System: Development of the AI for the system has lead to using a Scikit-Learn which assists in creating predictive models based on Regression, clustering, classification etc. To improve the infrared thermometry for low emissivity sources, work on the fabrication of a tandem photoconductive infrared thermometer was a main focus. Distance-Voltage-Temperature response data has been collected in the range of 7 cm - 100 cm and 200-400 deg. C. Modifications were made to the existing test bench to have a better control over the data. Automated data collection was realized using a Python code and an Arduino controlled stepper motor to increase the sample rate. A protective enclosure has been built around the setup to minimize the effect of the environment on the measurements. To better predict temperature, different AI models are being optimized. The regression model, LARS showed a high accuracy but had convergence issues and only works for the current test set-up. Results: The Transformable Wheel Robot has developed into a more flexible and modular platform. With the improvements to the current work, effort on the tire or soft gripper design been a large focus. The soft grippers will be interchange able to allow for increased performance in identified terrain types. The development of the liquid-based actuators allows the snake robotic platform to achieve the goals of being flexible and able to navigate confined spaces. However, there is room for improvement. Optimization work is currently being done in COMSOL Multiphysics. With the current IR system set-up the LARS model perfectly predicts the data; however, considering the mobility aspect of the project other models will allow for an optimized system. Testing of other model types is currently being done.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Report series: finding of effect and mitigation documentation for the mercury solar photovoltaic array and battery energy storage system, area 23, nevada national security site, nye county, nevada

The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) proposes to install solar photovoltaic (PV) power generation arrays and an associated battery energy storage system (BESS) for the town of Mercury at the Nevada National Security Site (NNSS) in Nye County, Nevada (Figure 1). The purposes of the development of this facility are to support long-term efforts to modernize Mercury and to provide energy-resilient infrastructure and address climate adaptation needs. Because it is within the boundary of the Mercury Historic District (MHD), it is subject to the terms of the Programmatic Agreement Between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada (hereafter referred to as the Mercury PA). An identification and evaluation report prepared for this undertaking determined that a contributing element to the MHD, the Mercury airstrip (26NY15777), is within the APE (Haynes 2024). The Mercury airstrip was developed following the closure of Camp Desert Rock in 1957 and used until late 1963 or 1964 when the Camp Desert Rock Airport was renovated, and the Mercury Bypass road constructed. The town of Mercury and the immediate surrounding area have been determined eligible for listing in the National Register of Historic Places (NRHP) as the MHD (SHPO Resource No. D230) under Criteria A and C for its importance in supporting nuclear testing and scientific research from 1951 through 1992 (Reed 2019). Originally recorded in 2016, 26NY15777 was determined individually not eligible for listing in the NRHP because it lacked sufficient integrity to convey its significance (Palmer 2016). It was subsequently determined in 2018 to be a contributing element of the MHD in an architectural survey of the district (Palmer 2018) and identified in Appendix C of the Mercury PA as a Category I contributing element. However, as per Stipulation IV.B.2, because the airstrip had already been formally evaluated and determined not to be individually eligible for the NRHP in consultation with the SHPO, this categorization was an error. NNSA/NFO reported this to the SHPO in Haynes 2024 and the SHPO concurred on June 11, 2024 (Reed). Accordingly, the airstrip is a Category II Property for the purposes of complying with the Mercury PA. The Mercury airstrip is a historic property for the purposes of compliance with Section 106 of the National Historic Preservation Act (NHPA) and subject to the stipulations of the Mercury PA.

25 ENERGY STORAGE↗

Economically Viable Intermediate to Long Duration Hydrogen Energy Storage Solutions for Fossil Fueled Assets

This report was prepared as an account of work sponsored by the Office of Fossil Energy and Carbon Management of U.S. Department of Energy under Funding Opportunity Announcement Number DE-FOA-0002332 “Energy Storage for Fossil Power Generation”. The work aimed to explore and advance an innovative hydrogen energy storage system – the synergistically integrated hydrogen energy storage system (SIHES) – that has the following characteristics: • Compatible with existing or new coal and gas fuel electricity generation units, • best suited for intermediate to long duration energy storage, from 12 hours to weeks even months, and • capable of storing energy at the utility scale – hundreds of MWh to GWh energy storage with power output level in tens to hundreds of MW. Preliminary front-end engineering design (Pre-FEED) studies was carried out to develop and refine a site-specific SIHES as peaking power generation units (so named as HyPeaker) as the first market entry point, to demonstrate both the technical feasibility and the economic viability to integrate the HyPeaker “within the fence” of a fossil power plant. This specific site was TVA’s Johnsonville Combustion Turbine Plant. The HyPeaker was designed and engineered to integrate with a 60MW aeroderivative gas turbine unit already available at TVA’s Johnsonville site. This site-specific HyPeaker consists of an alkaline electrolyzer to produce hydrogen from CO 2 free electricity sources, an innovative low-cost high-pressure hydrogen storage system (Big-Ton) and the aero gas turbine to generate electricity using blend of hydrogen and natural gas. A holistic system level technoeconomic analysis tool specific to HyPeaker was developed to optimize the engineering design of the Johnsonville site-specific HyPeaker for cost and performance. The optimal design and specification of the Johnsonville site-specific HyPeaker are the following: • Alkaline electrolyzer: 3MW • Big-Ton storage vessel: 11,000kg H 2 at 3000psi. • 4-stage diaphragm hydrogen compressor: 55kg-H 2 /hr from 150psi to 3000psi. The HyPeaker is designed to provide sufficient hydrogen for 90% continuous operation of the HyPeaker. All major components have design life of 30 years. The capex of HyPeaker is estimated at $\$$7.1M. This included $\$$1.5M for the electrolyzer, $\$$5.6M for the storage vessel and compressor. The cost of aero gas turbine was included as it is already available at the site. Key findings are: • HyPeaker can be designed, manufactured, installed and integrated with the fossil power plants, with sub-systems and components commercially available on the market today, even when it is scaled up to an order of magnitude larger than the one at the Johnsonville site. HyPeaker is a technologically viable solution to cover a wide range of energy storage duration needs, from daily peaking operation to seasonal shifting for fossil fueled assets. • The cost advantage of SCCV based Big-Ton H 2 storage vessel made it possible to “oversize” the H 2 storage subsystem to achieve overall system level cost optimization. The benefits are two-fold. First, it allows to significantly reduce the capacity and cost of electrolyzer by spreading H 2 production over a much longer period of time when the fuel cost for electricity production is low. Second, it allows to balance the hydrogen production and usage shift over weeks to months to meet the peak demands. As such, the capital cost of HyPeaker system using the Big-Ton was less than half of the cost of a system with today’s steel tube based H 2 storage system. The HyPeaker has even better cost advantage Li-ion battery based energy storage system. The estimated capital cost of Li-Ion battery system would be at $\$$38M, under the same projected 20-year electricity generation profile of the Johnsonville site. This is over 5 times more expensive than the HyPeaker system. • Since industry scale energy storage systems do not have 100% energy conversion and storage efficiency, energy storage systems using fossil fuel generated electricity would increase the CO 2 emission. This is particularly the case for HyPeaker due to its low round trip efficiency. Therefore, a more sensible solution would be to the excessive or curtailed electricity from CO 2 emission free sources such as solar farms, wind farms or nuclear power plants, to produce hydrogen, and integrate them with the HyPeaker. Electricity from TVA’s nuclear power plants was used for the Johnsonville HyPeaker. • The economic viability of HyPeaker is expected to be further improved when global supply chains are taken into consideration. For the same Johnsonville site specific HyPeaker, the capex would be reduced to ~$\$$3.6M from ~$\$$7.1M, and the added LCOE is reduced to ~$\$$85/MWh. With the bipartisan Infrastructure Investment and Jobs Act, the cost of domestically produced HyPeaker sub-systems would be at the level of today’s global suppliers. Since the peaking units generally operate at peak usage period, thereby demanding higher price, the projected $\$$85/MWh LCOE would be within the realm of financial viability for utility operators.

08 HYDROGEN↗