Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam independence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Photon-scattering cross sections of H2 and He measured with synchrotron radiation

Total (elastic + inelastic) differential photon-scattering cross sections have been measured for H2 gas and for He, using an X-ray beam. Absolute measured cross sections agree with theory within the probable errors. Relative cross sections (normalized to theory at large S) agree to better than 1% with theoretical values calculated from wave functions that include the effect of electron-electron Coulomb correlation, but the data deviate significantly from theoretical independent-particle (e.g., Hartree-Fock) results. The ratios of measured absolute He cross sections to those of H2, at any given S, also agree to better than 1% with theoretical He-to-H2 cross-section ratios computed from correlated wave functions. It appears that photon scattering constitutes a very promising tool for probing electron correlation in light atoms and molecules. The degree of polarization of the synchrotron radiation beam has been measured by rotating the scattering plane about the beam axis; results are compared with theory.

Ice, G. E.↗

Unsteady turbulent shear flow in shock tube discontinuities

A pressure-ruptured shock tube and an arc driven shock tube, have been used to study the evolution of turbulent fluctuations at contact surfaces with N2O4-2NO2 mixtures and at ionizing shock fronts in argon. The study has focused on point density diagnostics derived from crossed light beam correlations and electric probes. Turbulent bursts are found for which dynamical and spectral analyses suggest a particle-like evolution of fluctuation segments with a unique and characteristic frequency, independent of flow history and overall flow conditions.

Johnson, J. A., III↗

On the use of measured time delays in gravitational lenses to determine the Hubble constant

Gravitational lenses are rare in the known samples of quasars, indicating that the conditions involved in their formation are unusual. In particular, the distribution of matter along the light rays from the observer through the deflector to the quasar may be very different from mean conditions. It is shown that reasonable deviations in the density of matter along the beams can significantly alter the relationship between time delays and the Hubble constant, and it is concluded that gravitational lenses are not promising estimators of this constant. However, should an independent, precise determination of the Hubble constant become available, gravitational lenses could be used to probe long-range density fluctuations.

Alcock, C.↗

Application of an On-machine Gage for Diameter Measurements

This paper describes the design analysis and application of a laser based gage made specifically for measuring parts on the machine tool to a high accuracy. The tri-beam gage uses three beams of light to measure the local curvature of the part in a manner similar to a V-block gage. The properties of this design include: calibration that is independent of the machine tool scales, non-contact damage free operation, low cost of the gage, and the ability to measure parts in motion.

Harding, Kevin G.↗

Aircraft control system

A span-loaded, highly flexible flying wing, having horizontal control surfaces mounted aft of the wing on extended beams to form local pitch-control devices. Each of five spanwise wing segments of the wing has one or more motors and photovoltaic arrays, and produces its own lift independent of the other wing segments, to minimize inter-segment loads. Wing dihedral is controlled by separately controlling the local pitch-control devices consisting of a control surface on a boom, such that inboard and outboard wing segment pitch changes relative to each other, and thus relative inboard and outboard lift is varied.

Kendall, Greg T.↗

Active Dihedral Control System for a Torisionally Flexible Wing

A span-loaded, highly flexible flying wing, having horizontal control surfaces mounted aft of the wing on extended beams to form local pitch-control devices. Each of five spanwise wing segments of the wing has one or more motors and photovoltaic arrays, and produces its own lift independent of the other wing segments, to minimize inter-segment loads. Wing dihedral is controlled by separately controlling the local pitch-control devices consisting of a control surface on a boom, such that inboard and outboard wing segment pitch changes relative to each other, and thus relative inboard and outboard lift is varied.

Kendall, Greg T.↗

Active Dihedral Control System for a Torsionally Flexible Wing

A span-loaded, highly flexible flying wing, having horizontal control surfaces mounted aft of the wing on extended beams to form local pitch-control devices. Each of five spanwise wing segments of the wing has one or more motors and photovoltaic arrays, and produces its own lift independent of the other wing segments, to minimize inter-segment loads. Wing dihedral is controlled by separately controlling the local pitch-control devices consisting of a control surface on a boom, such that inboard and outboard wing segment pitch changes relative to each other, and thus relative inboard and outboard lift is varied.

Kendall, Greg T.↗

Searching for Sterile Neutrinos In the NOvA Experiment and Measurements of Hadronic Energy Response with NOvA Test Beam Data

The NOvA (NuMI Off-Axis electron neutrino Appearance) experiment is a long-baseline neutrino oscillation experiment composed of two functionally identical detectors: a 300-ton Near Detector and a 14-kton Far Detector, separated by 809 km and placed 14 mrad off the axis of the NuMI neutrino beam created at Fermilab. This configuration enables NOvA’s rich neutrino physics program, which includes measuring neutrino mixing parameters, determining the neutrino mass hierarchy, probing CP violation in the leptonic sector, studying neutrino cross sections, searching for sterile neutrinos, and more.\\ In this thesis I will present two independent analyses developed within the NOvA experiment. The first is a search for light sterile neutrino oscillations in the 3+1 framework using $\nu_\mu$-CC and NC samples from the NOvA Near and Far Detectors. Light sterile neutrinos are hypothetical neutral leptons that do not participate in the weak interactions but can mix with the three known active neutrinos: $\nu_e$, $\nu_\mu$, and $\nu_\tau$. Anomalous results, such as $\nu_e$/$\bar{\nu}e$ appearance in a $\nu_\mu$ ($\bar{\nu}_\mu$) beam observed by the MiniBooNE and LSND experiments, can be explained by the existence of sterile neutrinos. Thus, proving the existence of this type of neutrino is essential. The latest results of these searches in the NOvA experiment, along with contributions to this effort, will be presented.\\ The second is the first measurement of the pion energy response using data from the NOvA Test Beam experiment. The NOvA Test Beam experiment, deployed at Fermilab, uses a scaled-down 30-ton NOvA detector to analyze tagged beamline particles. The beamline can select and identify electrons, muons, pions, kaons, and protons with momenta ranging from 0.4 to 1.4 GeV/c. Pions are an important component of the hadronic system in neutrino interactions, and understanding how the detector responds to these particles is crucial for the validation of the simulation and the reduction of detector calibration uncertainties, which remain one of the largest systematic uncertainties in NOvA analyses.

Dueñas Tonguino, David Francisco [Cincinnati U.] (↗

An ultrasonic transducer with Gaussian radial velocity distribution

A transducer with a velocity profile which is Gaussian as a function of radius and independent of angle is described. In materials evaluation applications requiring the interrogation of modified far field patterns of an ultrasonic transducer, it is desirable to use a transducer which produces a beam with a Gaussian profile. A computer aided electrode design and calibrated three dimensional interferometric optical and ultrasonic measurements of the far field distribution are presented.

Zerwekh, P. S.↗

Determining F-factor using ground-based Doppler radar: Validation and results

Using a two-dimensional linear least-squares method applied to Doppler radar data, we test the viability of determining F-factor remotely. The ultimate application of such an algorithm will be supplying real-time F-factor maps, derived from ground-based Doppler radars to air traffic control personnel and pilots. Data from NASA deployments to the MIT/Lincoln Lab TDWR testbed radar in Orlando in 1991 and 1992 along with NASA deployments to the NCAR TDWR testbed radar in Denver are examined. Preliminary analyses show that the two-dimensional method correlates reasonably well with in situ measurements. Several effects, independent of the method used, act to reduce the correlation to less than one. These include time differences between radar and aircraft data, vertical misalignment between the aircraft and the radar beam, different spatial resolution scales between aircraft and radar data, inhomogeneous radar beam filling, noise in radar data that eludes filtering, and phase lag between time and space due to low pass filtering of the aircraft data. In the final assessment, it appears that a shear-based F-factor algorithm is preferable to the currently implemented TDWR algorithms which lack any local shear estimates.

Elmore, K. L.↗

A phase-stepped point diffraction interferometer using liquid crystals

A new instrument, the liquid crystal point diffraction interferometer (LCPDI), has been developed for the measurement of phase objects. This instrument maintains the compact, robust design of Linnik's point diffraction interferometer (PDI) and adds to it phase stepping capability for quantitative interferogram analysis. The result is a compact, simple to align, environmentally insensitive interferometer capable of accurately measuring optical wavefronts with high data density and with automated data reduction. The design of the LCPDI is briefly discussed. An algorithm is presented for eliminating phase measurement error caused by object beam intensity variation from frame-to-frame. The LCPDI is demonstrated by measuring the temperature distribution across a heated chamber filled with silicone oil. The measured results are compared to independently measured results and show excellent agreement with them. It is expected that this instrument will have application in the fluid sciences as a diagnostic tool, particularly in space based applications where autonomy, robustness, and compactness are desirable qualities. It should also be useful for the testing of optical elements, provided a master is available for comparison.

Mercer, Carolyn R.↗

An evaluation of energy-independent heavy ion transport coefficient approximations

Utilizing a one-dimensional transport theory for heavy ion propagation, evaluations of typical energy-dependent transport coefficient approximations are made by comparing theoretical depth-dose predictions to published experimental values for incident 670 MeV/nucleon Ne-20 beams in water. Results are presented for cases where the input nuclear absorption cross sections, or input fragmentation parameters, or both, are fixed. The lack of fragment charge and mass concentration resulting from the use of Silberberg-Tsao fragmentation parameters continues to be the main source of disagreement between theory and experiment.

Townsend, L. W.↗

Progress in modelling fast-ion D-alpha spectra and neutral particle analyzer fluxes using FIDASIM

FIDASIM is a code that models signals produced by charge-exchange reactions between neutrals and ions (both fast and thermal) in magnetically confined plasmas. With the ion distribution function as input, the code predicts the efflux to a neutral particle analyzer diagnostic and the photon radiance of Balmer-alpha light to a fast-ion D α diagnostic, in addition to many other related quantities. A new, parallelized version of the Monte Carlo code FIDASIM has been developed in Fortran90 that is substantially faster than the original interactive data language version. Modified algorithms include more accurate treatments of the time dependent collisional-radiative equations that describe neutral energy levels, of the cloud of ‘halo’ neutrals that surround the injected neutral beam, and of finite Larmor radius effects. Enhanced physics capabilities include modelling ‘passive’ signals from cold edge neutrals, the ability to treat general three-dimensional magnetic confinement configurations, and calculations of diagnostic-specific weight functions that enable tomographic reconstructions of the fast-ion distribution function. Neutral beam attenuation, beam emission, and fast-ion birth profiles are also modelled. Finally, the new algorithms have been successfully validated against experimental data and new features have been tested through benchmarks between two independently developed versions of the code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultimate Precision on Sin^2 Theta_23 With the Numi Experiments

There were two major goals to this proposal: the study of the discrepancy between data and MC in the NuMI Medium Energy neutrino beam and the incorporation of the MINOS and NOVA neutrino oscillation datasets. The first topic was approached via development of a simulation of the NuMI beam monitoring instrumentation suite. Initially, the Horn-Off current data sets were used to measure a set of hadron production parameters which improved the data/MC agreement in a way which was independent of the focusing parameters. The peak position discrepancy was only explained by a large (10kA) reduction in the horn current. A full simulation of the muon monitors was developed to attempt to make an independent measurement of the horn current by means of differential data taken by those monitors. While only at the 5kA level, the result corroborated the former findings. The second goal has not yet been completed but progress has focused on understanding how to modify the MINOS MC to take into account the MEC contribution which is missing from the underlying NEUGEN MC. A number of improvements to the MINOS reconstruction have been necessary. The framework to run the fits on the combined data has been completed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for a Long-Lived $\mu\mu$ Resonance in the NuMI Beam at ICARUS

The ICARUS detector in the Short-Baseline Neutrino program at Fermilab is sensitive to “long-lived” new physics particles that would be produced in the Neutrinos at the Main Injector (NuMI) beam and decay inside the ICARUS liquid argon time projection chamber (LArTPC). We show results from a new analysis in ICARUS which searched for di-muon decays from a long-lived particle produced in kaon decay in the NuMI beam. The search is sensitive to new areas of parameter space for the Higgs portal scalar and an axion-like particle model. The sensitivity is also presented in a model-independent way applicable to any new physics model predicting the process $K \to \pi+S(\to\mu\mu)$, for a long-lived particle S. This is the first search for new physics performed with the ICARUS detector at Fermilab. It paves the way for the future program of long-lived particle searches at ICARUS.

43 PARTICLE ACCELERATORS↗

Short Circuit Detection and Voltage Sense for High Voltage Ionization Tube Power Supplies

Fermilab's PIP-II upgrade requires new rack-mounted power supplies for Beam Loss Monitor (BLM) ionization tubes compatible with the microTCA 4.1 standard, supporting high-side current measurement for short circuit detection, voltage sense telemetry, and low-side current measurement for beam loss readout. This work presents the design and preliminary schematic of such a supply. A resistive current sensing approach was chosen over inductive, optical, and Hall-effect alternatives for its independence from cable length and component availability. A 500 mΩ inline shunt steps the 2 kV common mode voltage down to roughly 70 V, producing a ~27 μV pulse during a short, which is amplified 500x, compared against a 14-bit DAC threshold, and latched to drive a fault line. Voltage sense steps the 2 kV output down at a 1V/1000V ratio, buffers it with a low bias current amplifier, and digitizes it via a 24-bit ADC over SPI. Onboard power is regulated from 12 V down to isolated 5 V and 3.3 V rails, with capacitive isolation on FPGA communication lines. Lumped parameter models were developed for the ionization tube (0.327 nF, 20 to 200 GΩ dynamic resistance) and the RG-58 coaxial cable to support the design. Component selection is complete and a preliminary schematic has been drawn in Altium Designer, forming the foundation for future prototyping and validation.

Yu, Kellen [Cornell U.]↗

A Study of the Radiation Tolerance of CVD Diamond to 70 MeV Protons, Fast Neutrons and 200 MeV Pions

We measured the radiation tolerance of commercially available diamonds grown by the Chemical Vapor Deposition process by measuring the charge created by a 120 GeV hadron beam in a 50 μm pitch strip detector fabricated on each diamond sample before and after irradiation. We irradiated one group of samples with 70 MeV protons, a second group of samples with fast reactor neutrons (defined as energy greater than 0.1 MeV), and a third group of samples with 200 MeV pions, in steps, to (8.8±0.9) × 1015 protons/cm2, (1.43±0.14) × 1016 neutrons/cm2, and (6.5±1.4) × 1014 pions/cm2, respectively. By observing the charge induced due to the separation of electron–hole pairs created by the passage of the hadron beam through each sample, on an event-by-event basis, as a function of irradiation fluence, we conclude all datasets can be described by a first-order damage equation and independently calculate the damage constant for 70 MeV protons, fast reactor neutrons, and 200 MeV pions. We find the damage constant for diamond irradiated with 70 MeV protons to be 1.62±0.07(stat)±0.16(syst)× 10−18 cm2/(p μm), the damage constant for diamond irradiated with fast reactor neutrons to be 2.65±0.13(stat)±0.18(syst)× 10−18 cm2/(n μm), and the damage constant for diamond irradiated with 200 MeV pions to be 2.0±0.2(stat)±0.5(syst)× 10−18 cm2/(π μm). The damage constants from this measurement were analyzed together with our previously published 24 GeV proton irradiation and 800 MeV proton irradiation damage constant data to derive the first comprehensive set of relative damage constants for Chemical Vapor Deposition diamond. We find 70 MeV protons are 2.60 ± 0.29 times more damaging than 24 GeV protons, fast reactor neutrons are 4.3 ± 0.4 times more damaging than 24 GeV protons, and 200 MeV pions are 3.2 ± 0.8 more damaging than 24 GeV protons. We also observe the measured data can be described by a universal damage curve for all proton, neutron, and pion irradiations we performed of Chemical Vapor Deposition diamond. Finally, we confirm the spatial uniformity of the collected charge increases with fluence for polycrystalline Chemical Vapor Deposition diamond, and this effect can also be described by a universal curve.

36 MATERIALS SCIENCE↗

Optical mass memory investigation

The MASTER 1 optical mass storage system advanced working model (AWM) was designed to demonstrate recording and playback of imagery data and to enable quantitative data to be derived as to the statistical distribution of raw errors experienced through the system. The AWM consists of two subsystems, the recorder and storage and retrieval. The recorder subsystem utilizes key technologies such as an acoustic travelling wave lens to achieve recording of digital data on fiche at a rate of 30 Mbits/sec, whereas the storage and retrieval reproducer subsystem utilizes a less complex optical system that employs an acousto-optical beam deflector to achieve data readout at a 5 Mbits/sec rate. The system has the built in capability for detecting and collecting error statistics. The recorder and storage and retrieval subsystems operate independent of one another and are each constructed in modular form with each module performing independent functions. The operation of each module and its interface to other modules is controlled by one controller for both subsystems.

Source record↗