Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam profile”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Fast ion transport by sawtooth instability in the presence of ICRF-NBI synergy in JET plasmas

JET experiments have shown that the three-ion scenarios using waves in the ion cyclotron range of frequencies (ICRF) is an efficient way to build fast ion population through beam ion acceleration by radio frequency (RF) waves. Here, such a heating scheme is applied to plasmas with at least two thermal ion species. Analysis of mixed discharges with complex heating schemes requires a workflow that allows to model thermal and fast ion transport consistently. This paper is dedicated to modelling of a mixed plasma discharge with significant fraction of fast ions and contributes to development of fast ion transport models. For interpretive analysis with the TRANSP code a JET hydrogen-deuterium (HD) plasma discharge with neutral beam injection (NBI) and ICRF heating has been chosen. The task is complicated by NBI-ICRF synergy and plasma magnetohydrodynamic activity, like sawtooth crashes. D beam ions accelerated by RF waves form a high energy tail in fast ion distribution. Significant difference between the neutron rate computed by TRANSP and measured one is observed if the same diffusivity for electrons and ions is assumed. Sensitivity studies show that uncertainties in input plasma parameters and thermal ion transport models are crucial for modelling mixed plasma discharges and increased D transport is required to reach the plasma composition consistent with diagnostic measurements at the plasma edge. Fast ion redistribution by a sawtooth instability is characterised by non-resonant transport due to reconnection of magnetic field lines and resonant transport caused by resonance interaction between the instability and fast ions. With ORBIT simulations it has been shown that resonant interaction strongly affects fast ions of high energies, like beam ions accelerated by RF waves and fusion products. For the considered case, fast ion profiles simulated by ORBIT remain peaked after the sawtooth crashes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Perturbative analysis of low-frequency instabilities in high-field ST40 experiments

Abstract Linear and nonlinear perturbative analyses of low-frequency instabilities are presented for ST40 spherical torus high field plasmas, with simultaneous neutral beam heating due to two tangential sources at 25 keV and 55 keV. Initial plasma profiles on which the TRANSP and NUBEAM codes were based were obtained using an integrated analysis of several diagnostics including line-of-sight integrated and volume average measurements, as well as limited profile information from a charge-exchange-recombination spectrometer. Magnetohydrodynamics (MHD) analysis using the NOVA/NOVA-K codes suggests that the modes in the experiments are core-localized n = 1 eigenmodes with mixed acoustic and electromagnetic Alfvénic polarization. The global transport combined with the perturbative mode analysis indicates that there is greater tendency for bursty chirping response as the level of background micro-turbulence decreases in time and those predictions are shown to be consistent with the experimental data. This finding is interpreted in terms of the suppression of coherent phase-space structures that support chirping when the resonant fast ion dynamics is dominated by frequent stochastic, orbit-decorrelating events.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear Alfvén instability simulation and EP transport for ITER reversed shear (steady-state) and monotonic q-profile regimes *

The nonlinear evolution and dynamics of energetic particle (EP) driven instabilities in both steady-state (reversed shear q-profile) and monotonic q-profile regimes of ITER are examined using the global gyro-Landau closure model FAR3d. Both neutral beam and alpha components are included, leading to synergistic effects between the two populations. In order to maintain computational feasibility, the present nonlinear simulation includes all toroidal mode numbers ranging from n = 0 to 15. It cannot be excluded that n’s above this range could introduce larger linear growth rates; however, as indicated from the results, the n = 0 to 15 range is sufficient to provide a strong linear drive and significant nonlinear transport effects. While the toroidal mode numbers n = 6,13 dominate the linear instability growth phase, nonlinear energy transfers in the saturated phase reverse this trend, leading to the dominance of lower n’s in the saturated phase of the simulation. Zonal flow structure generation and EP density flattening are further consequences of the nonlinear phase. The density profile flattening is caused by collectively driven EP radial transport fluxes, which have non-local characteristics. Instantaneous alpha particle transport fluxes are significant (Γ α ~ 2 x 10 20 m –2 s –1 ) for the reversed shear regime and lower (Γ α ~ 1.1 x 10 20 m –2 s –1 ) for the monotonic q-profile case.

AE↗

Unabsorbed light beamlets for diagnosing coronal density profiles and absorption nonuniformity in direct-drive implosions on OMEGA

Laser light scattered from a target is the most-direct measurement for diagnosing laser absorption in a direct-drive implosion. The 3ωGOI (gated optical imager) beamlets diagnostic images unabsorbed light from all 60 OMEGA beams as distinct “beamlet” spots for each beam. The implosion can be diagnosed using the position and intensity of these beamlets. The position of each beamlet in the image is determined by refraction and can be used to fit the coronal plasma density profile of the implosion. The inferred plasma density profiles are comparable to profiles predicted by the 1-D hydrodynamics code LILAC but suggest the predictions underestimate the density farther out in the corona. The intensity of light in each spot depends on the cumulative effects of absorption and cross-beam energy transfer along the beamlet’s path through the corona. Furthermore, the measured variation in intensity and polarization between similar spots indicates that absorption during OMEGA implosions is less uniform than previously known.

47 OTHER INSTRUMENTATION↗

Magnetic design of the commutational magnet and quadrupoles for PERLE accelerator

PERLE (Powerful Energy Recovery LINAC for Experiment) is a high-power Energy Recovery LINAC (ERL) facility with 20 mA beam current and beam energy from 250 MeV to 500 MeV featuring three passes through two cryomodules. It is a hub for validation of the ERL technology development towards future energy and intensity frontier machines. Design challenges of PERLE and its beam parameters make it a test-bed to validate multi-turn high current ERL operation for the LHeC. It will be the first ERL for some pioneering experiment of the eN interaction with radioactive nuclei. In this work, design and optimization of the commutational magnet (B-com) used to spread/combine the three beams and one series of the quadrupole magnet is discussed. It gives the design parameters including: yoke geometry, pole profile, and material, and calculation of the excitation current needed to drive the magnet, the coil parameters and the number of turns. The B-com magnet is optimized for a 30° bending angle with magnetic field of 0.88 T along the magnet length and a harmonic content of 0.036%. The quadrupole magnet is designed for a gradient field of 34.15 T/m and experiences saturation above this value. Further studies to avoid saturation and achieve the maximum gradient of 44.1 T/m required by the beam dynamics is undergoing.

Abukeshek, R.↗

Magnetic design of the commutational magnet and quadrupoles for PERLE accelerator

PERLE (Powerful Energy Recovery LINAC for Experiment) is a high-power Energy Recovery LINAC (ERL) facility with 20 mA beam current and beam energy from 250 MeV to 500 MeV featuring three passes through two cryomodules. It is a hub for validation of the ERL technology development towards future energy and intensity frontier machines. Design challenges of PERLE and its beam parameters make it a test-bed to validate multi-turn high current ERL operation for the LHeC. It will be the first ERL for some pioneering experiment of the eN interaction with radioactive nuclei. In this work, design and optimization of the commutational magnet (B-com) used to spread/combine the three beams and one series of the quadrupole magnet is discussed. It gives the design parameters including: yoke geometry, pole profile, and material, and calculation of the excitation current needed to drive the magnet, the coil parameters and the number of turns. The B-com magnet is optimized for a 30° bending angle with magnetic field of 0.88 T along the magnet length and a harmonic content of 0.036%. The quadrupole magnet is designed for a gradient field of 34.15 T/m and experiences saturation above this value. Further studies to avoid saturation and achieve the maximum gradient of 44.1 T/m required by the beam dynamics is undergoing.

Abukeshek, R.↗

An automated approach to the alignment of compound refractive lenses

Compound refractive lenses (CRLs) are established X-ray focusing optics, and are thus a key element of many beamlines at X-ray facilities, used to either to focus a beam or image a sample. While CRLs are quite established, the stack of single lens elements affords a very small numerical aperture because of the thick lens profile, making them far more difficult to align than classical optical lenses that obey the thin-lens approximation. This means that the alignment must be very precise and is highly sensitive to changes to the incident beam; aligning CRLs is thus typically treated as a time-consuming manual process. Many groups circumvent day-to-day realignment by using engineering controls (e.g. mounting optics) that sacrifice some of the beam’s focusing characteristics, i.e. spot size, or resolution. While these choices minimize setup time, there are clear disadvantages. This work presents a new automated approach to align CRLs using a simple alignment apparatus that is easy to adapt and install at different types of X-ray experiments or facilities. Our approach builds on recent CRL modeling efforts, using an approach based on the Stochastic Nelder-Mead (SNM) simplex method. We demonstrate the efficacy of this method by numerical simulation and then extend this test to real experiments conducted at the Advanced Photon Source to confirm its performance with a synchrotron X-ray beam. This work provides an opportunity to automate key instrumentation at X-ray facilities.

97 MATHEMATICS AND COMPUTING↗

Adaptive model tuning studies for non-invasive diagnostics and feedback control of plasma wakefield acceleration at FACET-II

Beam-driven plasma wakefield acceleration (PWFA) achieves the same energy gain in a single meter, for which conventional accelerators require several kilometers, however much work is still required to match the beam quality of conventional accelerators. The PWFA processes to be studied at the FACET-II facility will utilize extremely short (down to a few fs) high energy (10 GeV), high charge (few nC) electron and eventually positron bunches. The PWFA process is extremely sensitive to the detailed longitudinal current profiles of these bunches and it would be of great benefit to have precise measurement and control of these profiles. We present an adaptive model tuning technique for FACET-II to adaptively tune online models based on real time accelerator and beam data to continuously provide a non-invasive diagnostic which predicts the longitudinal phase space (LPS) of extremely short and highly compressed electron beams, which otherwise require destructive X-band transverse deflecting cavity (XTCAV)-based measurements. Based on simulation studies, our method has the potential for: (1). The development of a non-invasive longitudinal phase space diagnostic by adaptively tuning models based on non-invasive measurements such as energy spread spectra which could be recorded at all of the bunch compressors in the facility. (2). Utilize these diagnostic to perform model-independent feedback-based to achieve desired longitudinal phase space distributions. (3). Utilize the model-independent feedback approach to maximize energy gain while minimizing emittance growth and energy gain variance of the PWFA process by tuning accelerator parameters, while monitoring what longitudinal phase space the algorithm has found, information that will be useful for further analytical and simulation studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Turbulence-reduced high-performance scenarios in Wendelstein 7-X

In the Wendelstein 7-X (W7-X) stellarator, turbulence is the dominant transport mechanism in most discharges. This leads to a 'clamping' of ion temperature over a wide range of heating power, predominantly flat density profiles where hollow profiles driven by neoclassical thermo-diffusion would be expected and by rapid impurity transport in injection experiments. Significantly reduced turbulent transport is observed in the presence of strong core density gradients found transiently after core pellet injection and irregularly after boronisation or boron pellet injection. Density peaking is also achieved in a controlled manner in purely neutral beam heated discharges where particle transport analysis reveals an abrupt reduction in the main-ion particle flux leading to significant density profile peaking not explained by the NBI particle source alone. The plasmas exhibit a heat diffusivity of around $\chi = 0.25 \pm 0.1\,\mathrm{m}^2\ \mathrm{s}^{-1}$ at mid radius, a factor of around 4 lower than ECRH dominated discharges. Despite the improved confinement, the achieved ion temperature is limited by broader heat deposition and the lower power-per-particle given the higher density. This is overcome with limited reintroduction of ECRH power, where the low heat diffusivity diffusivity is maintained, the density rise supressed and ion temperatures above the clamping limit are achieved. The applicability of these plasmas for a high performance scenario on transport relevant time scales is assessed, including initial predictions for planned heating upgrades of W7-X, based on a range of assumptions about particle transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase front retrieval and correction of Bessel beams

Bessel beams generated with non-ideal axicons are affected by aberrations. We introduce a method to retrieve the complex amplitude of a Bessel beam from intensity measurements alone, and then use this information to correct the wavefront and intensity profile using a deformable mirror.

36 MATERIALS SCIENCE↗

2x2 Demonstrator High-Coverage Light Readout System in a Novel LArTPC

DUNE is a long-baseline Liquid Argon Time Projection Chamber (LArTPC) neutrino oscillation experiment. Its near detectors, located at Fermi National Laboratory, will constrain systematic errors on far detector measurements. The 2x2 Demonstrator, a novel proof of concept prototype for the ND LArTPC, has a modular TPC design that mitigates event pileup in a high-occupancy nearline beam environment, further aided by a native 3D pixelated charge readout and a 30% coverage, low profile light readout. This will be the first large-scale LArTPC to utilize pixels in place of wire planes

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Luminosity measurement for lead-lead collisions at $\sqrt{s_{\mathrm{NN}}}$ = 5.02 TeV in 2015 and 2018 at CMS

Measurements of the luminosity delivered to the CMS experiment during the lead-lead data-taking periods in 2015 and 2018 are presented for the first time. The collisions were recorded at a nucleon-nucleon center-of-mass energy of 5.02 TeV; the 2018 data sample is three times larger than the 2015 data sample. Three subdetectors are used: the pixel luminosity telescope, the forward hadron calorimeters, and the fast beam conditions monitor. The absolute luminosity calibration is determined using the van der Meer technique that relies on transverse beam separation scans. The dominant sources of uncertainty are the transverse factorizability of the bunch density profiles and, in 2015, the difference between the results obtained using various detectors. The total uncertainty in the integrated luminosity, including the stability of the calibrated subdetector response over time, amounts to 3.0% for 2015, 1.7% for 2018, and 1.6% for the combined data sample.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Isotopic mass effects of tritium-fueled high-performance TFTR supershots

An increase in total stored energy correlated with the addition of tritium fuel was observed in supershots during the TFTR DT campaign. This supershot regime had strikingly high, centrally peaked ion and electron temperatures, and the largest neutron emission rates observed in TFTR. This paper presents a study of the causes of this increase in stored energy in supershots. Twenty-six supershots have been recently reanalyzed with the TRANSP plasma analysis code. Early TRANSP simulations did not accurately match the measured magnitude and time evolutions of the neutron emission rates. This mismatch is attributed to neglecting apparent increases of trace amounts of heavy impurities during neutral beam injection. The new TRANSP runs were tuned to accommodate this and match the measured global neutron emission rates. These new runs also had improved fidelity in predicting the time histories and radial dependencies of measured DT neutron emission rates. That in turn adds confidence in the simulated thermal deuterium and tritium density profiles that are needed for calculating the average hydrogenic atomic mass profiles. Six subsets of these supershots had well matched toroidal field B tor , plasma current I p , flux geometry, and total injected neutral beam power. The mix of D and T beam ions was varied for different discharges. The magnitude of the increase of the thermal ion energy W i with added tritium was relatively small, and the total W tot increase is dominated by the increase in fast beam ions with T. Analyses at times before the occurrences of deleterious MHD instabilities yielded scaling of W tot with the volume-average isotopic mass consistent with previous publications. The relative fraction of fast energy ions is expected to be small in practical tokamak reactors. Thus the increase in stored energy W tot observed in TFTR supershots does not appear likely to be significantly helpful for producing useful fusion energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Methodology for deriving the telescope focus function and its uncertainty for a heterodyne pulsed Doppler lidar

Doppler lidars provide two measured parameters, radial velocity and signal-to-noise ratio, from which winds and turbulent properties are routinely derived. Attenuated backscatter, which gives quantitative information on aerosols, clouds, and precipitation in the atmosphere, can be used in conjunction with the winds and turbulent properties to create a sophisticated classification of the state of the atmospheric boundary layer. Calculating attenuated backscatter from the signal-to-noise ratio requires accurate knowledge of the telescope focus function, which is usually unavailable. Inaccurate assumptions of the telescope focus function can significantly deform attenuated backscatter profiles, even if the instrument is focused at infinity. Here, we present a methodology for deriving the telescope focus function using a co-located ceilometer for pulsed heterodyne Doppler lidars. The method was tested with Halo Photonics StreamLine and StreamLine XR Doppler lidars but should also be applicable to other pulsed heterodyne Doppler lidar systems. The method derives two parameters of the telescope focus function, the effective beam diameter and the effective focal length of the telescope. Additionally, the method provides uncertainty estimates for the retrieved attenuated backscatter profile arising from uncertainties in deriving the telescope function, together with standard measurement uncertainties from the signal-to-noise ratio. The method is best suited for locations where the absolute difference in aerosol extinction at the ceilometer and Doppler lidar wavelengths is small.

54 ENVIRONMENTAL SCIENCES↗

Feasibility study of a high spatial and time resolution beam emission spectroscopy diagnostic for localized density fluctuation measurements in Lithium Tokamak eXperiment-β (LTX-β)

Trapped electron mode (TEM) is the main source of turbulence predicted for the unique operation regime of a flat temperature profile under low-recycling conditions in the LTX-β tokamak, while ion temperature gradient driven turbulence may also occur with gas fueling from the edge. To investigate mainly TEM scale density fluctuations, a high spatial and time resolution 2D beam emission spectroscopy (BES) diagnostic is being developed. Apart from spatially localized density turbulence measurement, BES can provide turbulence flow and flow shear dynamics. This BES system will be realized using an avalanche photodiode-based camera and narrow band interference filter. The system can acquire data at 2 MHz. Simulations with the Simulation of Spectra (SOS) code indicate that a high signal to noise ratio can be achieved with the proposed system. This will enable sampling the density fluctuations at this high time resolution. Finally, the design considerations and system optimization using the SOS code are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dispersion calibration for the National Ignition Facility electron–positron–proton spectrometers for intense laser matter interactions

Electron–positron pairs, produced in intense laser–solid interactions, are diagnosed using magnetic spectrometers with image plates, such as the National Ignition Facility Electron–Positron–Proton Spectrometers (EPPSs). Although modeling can help infer the quantitative value, the accuracy of the models needs to be verified to ensure measurement quality. The dispersion of low-energy electrons and positrons may be affected by fringe magnetic fields near the entrance of the EPPS. We have calibrated the EPPS with six electron beams from a Siemens Oncor linear accelerator (linac) ranging in energy from 2.7 MeV to 15.2 MeV as they enter the spectrometer. A Geant4 Tool for Particle Simulation Monte Carlo simulation was set up to match depth dose curves and lateral profiles measured in water at 100 cm source–surface distance. An accurate relationship was established between the bending magnet current setting and the energy of the electron beam at the exit window. The simulations and measurements were used to determine the energy distributions of the six electron beams at the EPPS slit. Furthermore, analysis of the scanned image plates together with the determined energy distribution arriving in the spectrometer provides improved dispersion curves for the EPPS.

47 OTHER INSTRUMENTATION↗

Radar - 449MHz - North Bend, OR (OTH) - Reviewed Data

**Winds.** A radar wind profiler measures the Doppler shift of electromagnetic energy scattered back from atmospheric turbulence and hydrometeors along 3-5 vertical and off-vertical point beam directions. Back-scattered signal strength and radial-component velocities are remotely sensed along all beam directions and are combined to derive the horizontal wind field over the radar. These data typically are sampled and averaged hourly and usually have 6-m and/or 100-m vertical resolutions up to 4 km for the 915 MHz and 8 km for the 449 MHz systems. **Temperature.** To measure atmospheric temperature, a radio acoustic sounding system (RASS) is used in conjunction with the wind profile. These data typically are sampled and averaged for five minutes each hour and have a 60-m vertical resolution up to 1.5 km for the 915 MHz and 60 m up to 3.5 km for the 449 MHz. **Moments and Spectra.** The raw spectra and moments data are available for all dwells along each beam and are stored in daily files. For each day, there are files labeled "header" and "data." These files are generated by the radar data acquisition system (LAP-XM) and are encoded in a proprietary binary format. Values of spectral density at each Doppler velocity (FFT point), as well as the radial velocity, signal-to-noise ratio, and spectra width for the selected signal peak are included in these files. Attached zip files, *449mhz-spectra-data-extraction.zip* and *449mhz-moment-data-extraction.zip*, include executables to unpack the spectra, (GetSpectra32.exe) and moments (GetMomSp32.exe), respectively. Documentation on usage and output file formats also are included in the zip files.

17 WIND ENERGY↗

Radar - 449MHz - Forks, WA (FKS) - Reviewed Data

**Winds.** A radar wind profiler measures the Doppler shift of electromagnetic energy scattered back from atmospheric turbulence and hydrometeors along 3-5 vertical and off-vertical point beam directions. Back-scattered signal strength and radial-component velocities are remotely sensed along all beam directions and are combined to derive the horizontal wind field over the radar. These data typically are sampled and averaged hourly and usually have 6-m and/or 100-m vertical resolutions up to 4 km for the 915 MHz and 8 km for the 449 MHz systems. **Temperature.** To measure atmospheric temperature, a radio acoustic sounding system (RASS) is used in conjunction with the wind profile. These data typically are sampled and averaged for five minutes each hour and have a 60-m vertical resolution up to 1.5 km for the 915 MHz and 60 m up to 3.5 km for the 449 MHz. **Moments and Spectra.** The raw spectra and moments data are available for all dwells along each beam and are stored in daily files. For each day, there are files labeled "header" and "data." These files are generated by the radar data acquisition system (LAP-XM) and are encoded in a proprietary binary format. Values of spectral density at each Doppler velocity (FFT point), as well as the radial velocity, signal-to-noise ratio, and spectra width for the selected signal peak are included in these files. Attached zip files, *449mhz-spectra-data-extraction.zip* and *449mhz-moment-data-extraction.zip*, include executables to unpack the spectra, (GetSpectra32.exe) and moments (GetMomSp32.exe), respectively. Documentation on usage and output file formats also are included in the zip files.

17 WIND ENERGY↗