Search NASA⌕ Search

SEARCH · Search NASA

Results for “bragg diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Real time synchrotron x-ray diffraction measurements to determine material strength of shocked single crystals following compression and release

We present a method to use real time, synchrotron x-ray diffraction measurements to determine the strength of shocked single crystals following compression and release during uniaxial strain loading. Aluminum and copper single crystals shocked along [111] were examined to peak stresses ranging from 2 to 6 GPa. Synchrotron x rays were used to probe the longitudinal lattice strains near the rear free surface (16 and 5 {micro}m depths for Al and Cu, respectively) of the metal crystals following shock compression and release. The 111 diffraction peaks showed broadening indicating a heterogeneous microstructure in the released state. The diffraction peaks also shifted to lower Bragg angles relative to the ambient Bragg angle; the magnitude of the shift increased with increasing impact stress. The Bragg angle shifts and appropriate averaging procedures were used to determine the macroscopic or continuum strength following compression and release. For both crystals, the strengths upon release increased with increasing impact stress and provide a quantitative measure of the strain hardening that occurs in Al(111) and Cu(111) during the shock and release process. Our results for Al(111) are in reasonable agreement with a previous determination based solely on continuum measurements. Two points are noteworthy about the developments presented here: Synchrotron x rays are needed because they provide the resolution required for analyzing the data in the released state; the method presented here can be extended to the shocked state but will require additional measurements.

36 MATERIALS SCIENCE↗

Reactive radical facilitated reaction-diffusion modeling for holographic photopolymerization

A phenomenological concentration of reactive radical is proposed to take the role of curing light intensity in explicit proportion to the reaction rate for the conventional reaction-diffusion model. This revision rationally eliminates the theoretical defect of null reaction rate in modeling of the postcuring process, and facilitates the applicability of the model in the whole process of holographic photopolymerizations in photocurable monomer and nematic liquid crystal blend system. Excellent consistencies are obtained in both curing and postcuring processes between simulated and experimentally measured evolutions of the first order diffraction efficiency of the formed composite Bragg gratings.

36 MATERIALS SCIENCE↗

Deflection of a monochromatic THz beam by acousto-optic methods

The possibility of controlled deflection of an electromagnetic THz beam of a free-electron laser by acousto-optic (AO) methods has been demonstrated for the first time. The material of the AO deflector was chosen to be single-crystal germanium, which has a fairly large refractive index (n = 4.0) and a relatively low absorption coefficient for electromagnetic waves. The absorption coefficient α in germanium is 0.75 ± 0.02 cm{sup -1} at a wavelength λ = 140 μm. The diffracted beam intensity is shown to be maximum at an effective AO interaction length l = 1/α. A diffraction efficiency of 0.05% at a travelling acoustic wave power of 1.0 W is experimentally obtained. It is established that a change in the ultrasonic frequency from 25 to 39 MHz leads to variation in the external Bragg angle in the range from 19.5° to 27.5°. At a fixed Bragg angle θ{sub B} = 22.4° the frequency band of diffraction is 4.2 ± 0.1 MHz and the angular range of laser beam scanning reaches 2.5° ± 0.5°. The results obtained indicate that AO interaction can be used for controlled deflection of electromagnetic THz beams. (terahertz radiation)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electronic Melting of Silicon in Nanostructures using X-ray Forbidden Bragg Reflections

Abstract We carried out a short beamtime at the Pohang Accelerator Laboratory x-ray Free Electron Laser to perform a pump-probe (PP) laser excitation diffraction experiment on the silicon (222) forbidden Bragg peak. To limit the x-ray penetration, we used a “device layer” silicon film wafer bonded to a silicon substrate. The sample, specially fabricated by MEMC Electronic Materials, had a Si(100) substrate bonded to a 170 nm Si(100) film rotated at 45° for crystallographic isolation. A second sample was reactive-ion-etched down to 52 nm thickness. In the silicon lattice, the covalent bonds are seen exclusively at the 222 reflection. Upon laser excitation, these electrons are expected to be excited to the valence band on femtosecond electronic time scales. The Si(222) reflection is therefore expected to be extinguished on this fast time scale, while the electron–phonon coupled acoustic response is determined by the lattice dynamics. The latter is determined by the speed of sound over the device thickness, which is in the mid-picosecond range.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Atomically resolved structural determination of graphene and its point defects via extrapolation assisted phase retrieval

Previously reported crystalline structures obtained by an iterative phase retrieval reconstruction of their diffraction patterns seem to be free from displaying any irregularities or defects in the lattice, which appears to be unrealistic. We demonstrate here that the structure of a nanocrystal including its atomic defects can unambiguously be recovered from its diffraction pattern alone by applying a direct phase retrieval procedure not relying on prior information of the object shape. Individual point defects in the atomic lattice are clearly apparent. Conventional phase retrieval routines assume isotropic scattering. We show that when dealing with electrons, the quantitatively correct transmission function of the sample cannot be retrieved due to anisotropic, strong forward scattering specific to electrons. We summarize the conditions for this phase retrieval method and show that the diffraction pattern can be extrapolated beyond the original record to even reveal formerly not visible Bragg peaks. Such extrapolated wave field pattern leads to enhanced spatial resolution in the reconstruction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rotation of X-ray polarization in the glitches of a silicon crystal monochromator

EXAFS studies on dilute samples are usually carried out by collecting the fluorescence yield using a large-area multi-element detector. This method is susceptible to the `glitches' produced by all single-crystal monochromators. Glitches are sharp dips or spikes in the diffracted intensity at specific crystal orientations. If incorrectly compensated, they degrade the spectroscopic data. Normalization of the fluorescence signal by the incident flux alone is sometimes insufficient to compensate for the glitches. Measurements performed at the state-of-the-art wiggler beamline I20-scanning at Diamond Light Source have shown that the glitches alter the spatial distribution of the sample's quasi-elastic X-ray scattering. Because glitches result from additional Bragg reflections, multiple-beam dynamical diffraction theory is necessary to understand their effects. Here, the glitches of the Si(111) four-bounce monochromator of I20-scanning just above the Ni K edge are associated with their Bragg reflections. A fitting procedure that treats coherent and Compton scattering is developed and applied to a sample of an extremely dilute (100 micromolal) aqueous solution of Ni(NO 3 ) 2 . The depolarization of the wiggler X-ray beam out of the electron orbit is modeled. The fits achieve good agreement with the sample's quasi-elastic scattering with just a few parameters. The X-ray polarization is rotated up to ±4.3° within the glitches, as predicted by dynamical diffraction. These results will help users normalize EXAFS data at glitches.

Sutter, John P.↗

Digital electron diffraction – seeing the whole picture

Computer control of beam tilt and image capture allows the collection of electron diffraction patterns over a large angular range, without any overlap in diffraction data and from a region limited only by the size of the electron beam. This results in a significant improvement in data volumes and ease of interpretation. The advantages of convergent-beam electron diffraction for symmetry determination at the scale of a few nm are well known. In practice, the approach is often limited due to the restriction on the angular range of the electron beam imposed by the small Bragg angle for high-energy electron diffraction, i.e. a large convergence angle of the incident beam results in overlapping information in the diffraction pattern. Techniques have been generally available since the 1980s which overcome this restriction for individual diffracted beams, by making a compromise between illuminated area and beam convergence. Here a simple technique is described which overcomes all of these problems using computer control, giving electron diffraction data over a large angular range for many diffracted beams from the volume given by a focused electron beam (typically a few nm or less). The increase in the amount of information significantly improves the ease of interpretation and widens the applicability of the technique, particularly for thin materials or those with larger lattice parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High energy electron diffraction instrument with tunable camera length

Ultrafast electron diffraction (UED) stands as a powerful technique for real-time observation of structural dynamics at the atomic level. In recent years, the use of MeV electrons from radio frequency guns has been widely adopted to take advantage of the relativistic suppression of the space charge effects that otherwise limit the temporal resolution of the technique. Nevertheless, there is not a clear choice for the optimal energy for a UED instrument. Scaling to beam energies higher than a few MeV does pose significant technical challenges, mainly related to the inherent increase in diffraction camera length associated with the smaller Bragg angles. In this study, we report a solution by using a compact post-sample magnetic optical system to magnify the diffraction pattern from a crystal Au sample illuminated by an 8.2 MeV electron beam. Our method employs, as one of the lenses of the optical system, a triplet of compact, high field gradients (>500 T/m), small-gap (3.5 mm) Halbach permanent magnet quadrupoles. Shifting the relative position of the quadrupoles, we demonstrate tuning the magnification by more than a factor of two, a 6× improvement in camera length, and reciprocal space resolution better than 0.1 Å –1 in agreement with beam transport simulations.

47 OTHER INSTRUMENTATION↗

X-ray transition radiation of electrons with energy of 300 to 900 MeV in periodic multifoil radiators

Results: of experiments conducted at the Tomsk synchrotron to study resonant X-ray transition radiation generated by relativistic electrons in periodic multifoil radiators are reviewed. Both the internal synchrotron beam and the external secondary electron beam from the pair magnetic γ-spectrometer with energies ranging from 300 to 900 MeV were used in the experiments. The radiators consisted of many thin amorphous foils of various materials. The generation of X-ray radiation in a compound radiator consisting of a multifoil radiator and a crystal is also studied. In this case, the resonant X-ray transition radiation generated in the multifoil radiator is diffracted in the crystal and emitted at Bragg angles, together with the parametric X-ray radiation generated in the crystal. Spectral and angular properties of the resonant X-ray transition radiation and diffracted resonant X-ray transition radiation are investigated. The ratio between the contributions from the diffracted resonant X-ray transition radiation and other types of radiation to the total coherent X-ray radiation flux generated by electrons in periodic structures and crystals is estimated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization of Crystallographic Structures Using Bragg-Edge Neutron Imaging at the Spallation Neutron Source

Over the past decade, wavelength-dependent neutron radiography, also known as Bragg-edge imaging, has been employed as a non-destructive bulk characterization method due to its sensitivity to coherent elastic neutron scattering that is associated with crystalline structures. Several analysis approaches have been developed to quantitatively determine crystalline orientation, lattice strain, and phase distribution. In this study, we report a systematic investigation of the crystal structures of metallic materials (such as selected textureless powder samples and additively manufactured (AM) Inconel 718 samples), using Bragg-edge imaging at the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS). Firstly, we have implemented a phenomenological Gaussian-based fitting in a Python-based computer called iBeatles. Secondly, we have developed a model-based approach to analyze Bragg-edge transmission spectra, which allows quantitative determination of the crystallographic attributes. Moreover, neutron diffraction measurements were carried out to validate the Bragg-edge analytical methods. These results demonstrate that the microstructural complexity (in this case, texture) plays a key role in determining the crystallographic parameters (lattice constant or interplanar spacing), which implies that the Bragg-edge image analysis methods must be carefully selected based on the material structures.

47 OTHER INSTRUMENTATION↗

Multiscale in-situ characterization of static recrystallization using dark-field X-ray microscopy and high-resolution X-ray diffraction

Abstract Dark-field X-ray microscopy (DFXM) is a high-resolution, X-ray-based diffraction microstructure imaging technique that uses an objective lens aligned with the diffracted beam to magnify a single Bragg reflection. DFXM can be used to spatially resolve local variations in elastic strain and orientation inside embedded crystals with high spatial (~ 60 nm) and angular (~ 0.001°) resolution. However, as with many high-resolution imaging techniques, there is a trade-off between resolution and field of view, and it is often desirable to enrich DFXM observations by combining it with a larger field-of-view technique. Here, we combine DFXM with high-resolution X-ray diffraction (HR-XRD) applied to an in-situ investigation of static recrystallization in an 80% hot-compressed Mg–3.2Zn–0.1Ca wt.% (ZX30) alloy. Using HR-XRD, we track the relative grain volume of > 8000 sub-surface grains during annealing in situ. Then, at several points during the annealing process, we “zoom in” to individual grains using DFXM. This combination of HR-XRD and DFXM enables multiscale characterization, used here to study why particular grains grow to consume a large volume fraction of the annealed microstructure. This technique pairing is particularly useful for small and/or highly deformed grains that are often difficult to resolve using more standard diffraction microstructure imaging techniques.

36 MATERIALS SCIENCE↗

Fabrication and Study of a Concave Crystal Mirror for the KORTES Project

A method for fabrication of a concave spherical mirror made of crystalline quartz is proposed and X-ray optical properties of the mirror are studied. The radius of curvature is 1630 mm. The shape of the mirror surface is studied using an interferometer with a diffraction reference wave. In the entire processing region, the maximum deviation from the nearest sphere is about 0.2 μm and the rms is 34 nm, so that high quality of imaging is provided with an angular error of about 2″ (angular seconds). Reflection coefficient (about 7%) and lower bound limit of spectral selectivity (λ/δλ ≈ 1775) are determined in the vicinity of a wavelength of λ = 0.834 nm, which is close to the working wavelengths of the MgXII doublet (λ = 0.8418 and 0.8423 nm). Position of the Bragg peak and spectral selectivity remain unchanged upon bending of the crystal mirror within measurement accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neutron diffraction studies on chemical and magnetic structure of multiferroic PbFe{sub 0.67}W{sub 0.33}O{sub 3}

We report on the single phase synthesis and room temperature structural characterization of PbFe{sub 0.67}W{sub 0.33}O{sub 3} (PFW) multiferroic. The PFW was synthesized by low temperature sintering, Columbite method. Analysis of powder XRD pattern exhibits single phase formation of PFW with no traces of pyrochlore phase. Detailed analysis of room temperature neutron diffraction (ND) reveals cubic phase at room temperature, space group Pm-3m. The ND pattern clearly reveals magnetic Bragg peak at 2θ = 18.51° (Q = 1.36Å{sup −1}). The refinement of magnetic structure reveals G-type antiferromagnetic structure in PFW at room temperature. The dielectric constant and loss tangent decreases with increasing frequency. The room temperature P-E measurements shows a non-linear slim hysteresis, typical nature of relaxor multiferroics, with saturation and remnant polarizations of P{sub s} = 1.50 μC/cm{sup 2} and P{sub r} = 0.40 μC/cm{sup 2}, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-Ray Diffraction Study of the Internal Structure of Supercooled Water

A Bragg X-ray spectrometer equipped with a volume-sensitive Geiger counter and Soller slits and employing filtered molybdenum Ka radiation was used to obtain a set of diffracted intensity curves as a Punction of angle for supercooled water. Diffracted intensity curves in the temperature region of 21 to -16 C were obtained. The minimum between the two main diffraction peaks deepened continuously with lowering temperature, indicating a gradual change in the internal structure of the water. No discontinuity in this trend was noted at the melting point. The internal structure of supercooled water was concluded to become progressively more ice-like as the temperature is lowered.

Dorsch, Robert G.↗

Influence of diffraction in crystals on the coherence properties of X-ray free-electron laser pulses

The spatial and temporal evolution of the field of random X-ray femtosecond pulses and their coherent properties upon pulse propagation in free space and under dynamical diffraction in perfect crystals in the Bragg and Laue geometries has been analyzed on the basis of the formalism developed in statistical optics. Particular attention is paid to the influence of large pulse propagation distances, which are characteristic of lengthy channels of X-ray free-electron lasers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-Temperature Neutron Diffraction Study of Vanadium and Vanadium–Niobium Null-Matrix Alloy for Spectrum Normalization

This study systematically evaluates a vanadium–niobium (V 94.1 Nb 5.9 ) null-matrix alloy as a reference material for neutron spectrum normalization and compares its performance with that of pure vanadium under identical experimental conditions. Neutron diffraction experiments are conducted on the VULCAN Engineering Materials Diffractometer at the Spallation Neutron Source, Oak Ridge National Laboratory, over a temperature range from room temperature to 1200 °C under vacuum. Pure vanadium exhibited distinct Bragg peaks across all temperatures, with its diffraction behavior influenced by both sample orientation and temperature. As the temperature increased, the diffraction peaks shifted to larger d-spacings and decreased in intensity, while spectral deviation near d ≈ 2.8 Å exceeded 10% at 1200 °C. In contrast, the V–Nb alloy produced a nearly featureless spectrum over the full d-spacing range, confirming near-complete cancellation of coherent scattering over the wide temperature range. Its spectra were insensitive to sample orientation, temperature, and microstructural evolution, with spectral deviation around d ≈ 2.8 Å exceeded 5% at 1200 °C. In conclusion, these results demonstrate that the V–Nb null-matrix alloy provides a thermally stable, efficient, and reliable normalization standard for time-of-flight diffractometers or other instrument where it is needed, enabling reduced data acquisition time and improved data quality in high-temperature neutron diffraction experiments.

Alloys↗

Interfacial reconstruction effects in insulating double perovskite Nd2NiMnO6/SrTiO3 and Nd2NiMnO6/NdGaO3 thin films

Ferromagnetic insulating (FMI) double perovskite oxides (DPOs) A2BB′O6 with near-room-temperature Curie temperatures are promising candidates for ambient-temperature spintronics applications. To realize their potential, epitaxial stabilization of DPO films and understanding the effect of multiple broken symmetries across the film/substrate interface are crucial. This study investigates ultrathin films of the FMI Nd2NiMnO6 grown on SrTiO3 (STO) and NdGaO3 (NGO) substrates. By comparing growth on these substrates, we examine the influence of polarity and structural symmetry mismatches, which are absent in the NGO system. The interface exhibits immeasurable resistance in both cases. Using synchrotron x-ray diffraction, we show that films have three octahedral rotational domains because of the structural symmetry mismatch with the STO substrate. Furthermore, our coherent Bragg rod analysis of specular x-ray diffraction reveals a significant modification of the out-of-plane lattice parameter within a few unit cells at the film/substrate interface and the surface. This arises from polarity compensation and surface symmetry breaking, respectively. These structural alterations influence the Mn orbital symmetry, a dependence that we further confirm through x-ray linear dichroism measurements. Since the ferromagnetism in insulating DPOs is mediated by orbital-dependent superexchange interactions [Phys. Rev. Lett. 100, 186402 (2008)0031-900710.1103/PhysRevLett.100.186402], our study provides a framework for understanding the evolution of magnetism in ultrathin geometry.

Bhattacharya, Nandana↗

A W/B{sub 4}C Transmission Multilayer as an Achromatic Phase Shifter in the XUV: Some Experimental Aspects

Completing previous investigations we study a W/B{sub 4}C transmission multilayer with 350 periods each 1.74 nm as a phase shifter for polarization analysis between 720 eV and 1020 eV. The FWHM of the Bragg curve is as small as 0.18 deg. = 3 mrad and thus smaller than the inherent accuracy of most polarimeters. We discuss some of the experimental implications and limitations. We obtain a phase shift of up to {Delta} = 24 deg. through out the spectral range.

43 PARTICLE ACCELERATORS↗