Search NASA⌕ Search

SEARCH · Search NASA

Results for “cable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

Vibration Analysis of the Space Shuttle External Tank Cable Tray Flight Data With and Without PAL Ramp

External Tank Cable Tray vibration data for three successive Space Shuttle flights were analyzed to assess response to buffet and the effect of removal of the Protuberance Air Loads (PAL) ramp. Waveform integration, spectral analysis, cross-correlation analysis and wavelet analysis were employed to estimate vibration modes and temporal development of vibration motion from a sparse array of accelerometers and an on-board system that acquired 16 channels of data for approximately the first 2 min of each flight. The flight data indicated that PAL ramp removal had minimal effect on the fluctuating loads on the cable tray. The measured vibration frequencies and modes agreed well with predicted structural response.

Walker, Bruce E.↗

Spacewire Cable and Connector Variations

SpaceWire spaceflight applications are growing steadily and the data protocol is well documented and standardized. Yet, unique requirements for various programs often make it necessary to deviate from the standard. The introduction of new technologies into the SpaceWire community can only serve to support increased technology growth. The physical layer is often overlooked as a critical component of the SpaceWire link but experience will show that in certain situations a good physical layer design may be crucial to the success of the program. The SpaceWire cable assembly, consisting of the SpaceWire connector and cable, is one of the components that may offer design variations.

Allen, Shaune S.↗

Bulk Current Injection Testing of Close Proximity Cable Current Return, 1kHz to 1 MHz

This paper presents the results of an experiment examining the percentage of current that returns on adjacent wires or through a surrounding cable shield rather than through a shared conducting chassis. Simulation and measurement data are compared from 1 kHz 1 MHz for seven common cable configurations. The phenomenon is important to understand, because minimizing the return current path is vital in developing systems with low radiated emissions.

Bradley, Arthur T.↗

SSME Electrical Harness and Cable Development and Evolution

The Space Shuttle Main Engine (SSME) electrical harness and cable system consists of the various interconnecting devices necessary for operation of complex rocket engine functions. Thirty seven harnesses incorporate unique connectors, backshell adapters, conductors, insulation, shielding, and physical barriers for a long maintenance-free life while providing the means to satisfy performance requirements and to mitigate adverse environmental influences. The objective of this paper is to provide a description of the SSME electrical harness and cable designs as well as the development history and lessons learned.

Abrams, Russ↗

Final Report: MaRSPlus Sensor System Electrical Cable Management and Distributed Motor Control Computer Interface

The success of JPL's Next Generation Imaging Spectrometer (NGIS) in Earth remote sensing has inspired a follow-on instrument project, the MaRSPlus Sensor System (MSS). One of JPL's responsibilities in the MSS project involves updating the documentation from the previous JPL airborne imagers to provide all the information necessary for an outside customer to operate the instrument independently. As part of this documentation update, I created detailed electrical cabling diagrams to provide JPL technicians with clear and concise build instructions and a database to track the status of cables from order to build to delivery. Simultaneously, a distributed motor control system is being developed for potential use on the proposed 2018 Mars rover mission. This system would significantly reduce the mass necessary for rover motor control, making more mass space available to other important spacecraft systems. The current stage of the project consists of a desktop computer talking to a single "cold box" unit containing the electronics to drive a motor. In order to test the electronics, I developed a graphical user interface (GUI) using MATLAB to allow a user to send simple commands to the cold box and display the responses received in a user-friendly format.

data cubes↗

Online Cable Tester and Rerouter

Hardware and algorithms have been developed to transfer electrical power and data connectivity safely, efficiently, and automatically from an identified damaged/defective wire in a cable to an alternate wire path. The combination of online cable testing capabilities, along with intelligent signal rerouting algorithms, allows the user to overcome the inherent difficulty of maintaining system integrity and configuration control, while autonomously rerouting signals and functions without introducing new failure modes. The incorporation of this capability will increase the reliability of systems by ensuring system availability during operations.

Lewis, Mark↗

Static Dissipative Cable Ties, Such as for Radiation Belt Storm Probes

An article, such as, but not limited to, a cable strap to wrap, support, or secure one or more wires or cables, is formed by cyclically heating and cooling and/or irradiating an article formed of a static dissipative ethylene tetrafluoroethylen (ETFE) resin, to reduce an electrical resistivity and/or to increase a tensile strength of the article.

Langley, Patrick T.↗

Practical Applications of Cables and Ropes in the ISS Countermeasures System

As spaceflight durations have increased over the last four decades, the effects of weightlessness on the human body are far better understood, as are the countermeasures. A combination of aerobic and resistive exercise devices contribute to countering the losses in muscle strength, aerobic fitness, and bone strength of today's astronauts and cosmonauts that occur during their missions on the International Space Station. Creation of these systems has been a dynamically educational experience for designers and engineers. The ropes and cables in particular have experienced a wide range of challenges, providing a full set of lessons learned that have already enabled improvements in on-orbit reliability by initiating system design improvements. This paper examines the on-orbit experience of ropes and cables in several exercise devices and discusses the lessons learned from these hardware items, with the goal of informing future system design.

Moore, Cherice↗

Shield to Pin Coupling of Lightning-Like Transients on Payload Umbilical Cables on a Launch Pad

In this paper we describe in-situ testing of a long payload umbilical, on a launch site, injected with “lightning- like” transients and describe resulting pin-to-pin voltages. Injections and voltage measurements near the ground support equipment room, as well as at a location near the payload junction box, are made. The umbilical cables tested include an outer over-braid and the inner conductor coupling is examined for open circuit, short-circuit and various loads representative of spacecraft input impedances. This testing is important because the Kennedy Space Center (KSC) where the lightning occurrence is the highest in the United States, is the primary launch site for Launch Services Program spacecraft customers. Lightning planning is essential but developing a lightning plan is often overlooked or not adequately analyzed leaving the spacecraft vulnerable to time delays or even damage when lightning occurs. At other popular launch sites like Vandenberg Air Force Base (VAFB) where lightning occurs less often, although at the same or greater intensity when it does occur, lightning planning is often completely ignored by the spacecraft. The two major questions to be addressed in the lightning plan are what retesting should be done to establish a “goodness” level and what is the trigger criteria for this testing? The spacecraft will typically use a standard spacecraft check-out procedure to address the necessary retesting, but determining the trigger criteria is often an issue. For instance, a spacecraft needs to understand what their immunity is to a certain lightning magnitude and location. Determining the amount of current that can be coupled onto a spacecraft umbilical can be calculated by using worst case assumptions or measured with current probes and current measurement devices. Spacecraft can also determine what pin-to-pin voltages they are sensitive to, however pin-to-pin voltage measurements are not typically taken during the strike due to the invasive nature of this measurement. In this paper, we present detailed data on the shield to pin voltage transfer functions to provide insight to the spacecraft developers for lightning retest criteria planning. The results from this unique testing opportunity provide essential details on specific coupling mechanisms affecting spacecraft hardware that interfaces with the ground support equipment. This missing link between cable shield currents and payload susceptibility voltages has been methodically tested and representative data presented.

Trout, Dawn↗

Development and Characterization of Lightweight Durable Composite Conductor for Cables

Sustainable aviation in the form of electrified propulsion is likely to lead to an increase in the electrical assets contained within a single aircraft. As a result, it is desirable to design light weight conductor materials, thus reducing the payload of components like motor windings, low voltage signal cables, and transmission cables for data and power. One approach involves replacing pure Cu wiring with metalized CNT composites. This paper evaluates a framework for modeling overall conductivity and current sharing within such composites. Processing methods and parameters were refined. Select electroplated samples outperformed pure Cu in conductivity and had comparable ultimate tensile strengths. Tensile strengths are expected to improve with an additional densification step during processing. Acoustic emission data was used to predict the failure mechanism of the composite. Theories explaining improved intrinsic conductivity are discussed, with a focus on chemical and mechanical interactions at the Cu-CNT interface. These include Cu infiltration of CNT crevices, CNT oxidation, activity at defects in CNT walls, and the release of carbide-forming metals from CNT walls. Validating any or all these theories will require further work replicating data, collecting electron micrographs and conducting chemical analyses.

Metalized CNT↗

Optical fiber based sensing for smart electrical cables and distributed radiation detection

A cable device includes a sheath member, a number of electrical cables provided within the sheath member, and an optical fiber sensing member provided within the sheath member. The optical fiber sensing member includes a functionalized optical fiber based sensor device structured to exhibit a change in one or more optical properties in response to changes in a parameter of interest. Also, a method of sensing radiation includes introducing a source light into an optical fiber sensing member provided within a structure, wherein the optical fiber sensing member comprises a functionalized optical fiber based sensor device structured to exhibit a change in one or more optical properties in response to radiation, detecting sensing light generated in response to the source light, and determining a radiation level at a plurality of locations within the structure using the detected sensing light and a distributed sensing scheme.

Chen, Peng Kevin↗

Second generation superconducting filaments and cable

A high-temperature superconducting filament and cable, and a method for manufacturing same. The substrate used to grow the superconducting layer is removed, and the exfoliated superconducting layer is coated with a protective layer, and then sliced into narrow strips. The strips are thereafter encapsulated with a conductive metal to provide a high-temperature superconducting filament. The filaments may be bundled together to provide a high-temperature superconducting cable.

Solovyov, Vyacheslav↗

Hot-swappable no cable touch switch enclosure

A system for hot swapping a network switch without disconnecting the network switch connectors is provided. The system disaggregates the switch faceplate network cable connectors from the internal components of the network switch so that the internal switch components may be removed from the switch without disconnecting the switch network cables.

McDonald, Nicholas↗

Flexible multi-filament high temperature superconducting cable

A multi-filament high temperature superconducting cable having improved AC current carrying capacity, quench resistance and flexibility. The multi-filament cable is formed from a plurality of stacked exfoliated filaments which provide current sharing between adjacent superconducting layers.

Solovyov, Vyacheslav↗

Hot-swappable no cable touch switch enclosure

A system for hot swapping a network switch without disconnecting the network switch connectors is provided. The system disaggregates the switch faceplate network cable connectors from the internal components of the network switch so that the internal switch components may be removed from the switch without disconnecting the switch network cables.

McDonald, Nicholas George↗

Kinematics of a Cable-Driven Robotic Platform for Large-Scale Additive Manufacturing

Concrete additive manufacturing (AM) is a growing field of research. However, on-site, large-scale concrete additive manufacturing requires motion platforms that are difficult to implement with conventional rigid-link robotic systems. This article presents a new kinematic arrangement for a deployable cable-driven robot intended for on-site AM. The kinematics of this robot are examined to determine if they meet the requirements for this application, the wrench feasible workspace (WFW) is examined, and the physical implementation of a prototype is also presented. Data collected from the physical implementation of the proposed system are analyzed, and the results support its suitability for the intended application. The success of this system demonstrates that this kinematic arrangement is promising for future deployable AM systems.

36 MATERIALS SCIENCE↗

Correlation of Diffusion Limited Oxidation to Color Difference in Accelerated Aging of Electrical Cable Insulation

Diffusion limited oxidation (DLO) as a phenomenon has complicated material lifetime predictions from accelerated aging studies. Many methods to analyze DLO have been developed in recent years. However, an analytical tool for high throughput and low-cost analysis of DLO affected samples remains absent from the literature. Color differences in polymers exposed to oxidative conditions have recently been observed and correlated to increased concentrations of oxidation products. Herein, total color difference was utilized to rapidly quantify DLO in ethylene propylene rubber (EPR) polymeric cable insulation specimens. Insulation specimens were aged at 121 °C, 136 °C, 150 °C, and 165 °C and a 10% ?E*ab difference between the specimen edge and specimen center was used as the threshold for DLO. Based on these specifications DLO was observed in EPR insulation specimen at temperatures of 136 °C and above, with an increasing degree of DLO observed as the time of exposure increased. The method presented in this work represents a quantitative and high-throughput method for the investigation of DLO with a low cost barrier for entry.

diffusion limited oxidation, DLO, nuclear, electri↗

Color Change During Thermal Degradation of Polyolefin Electric Cable Insulations

Color change of electric cable insulations used in nuclear power plants (NPPs) is a non-destructive, quick and inexpensive technique to measure degradation. Quantification of color change is facilitated by a light booth of CIE D65 illuminant, a commercial camera and open-source software ImageJ with micaToolbox plugin. Yellowness index (YI) and total color difference (?E) are calculated from calibrated photos of a white cross-linked polyethylene (XLPE) and a black ethylene-propylene rubber (EPR) based specimens aged at 110°C, 121°C, 136°C and 150°C after 1~640 days. Using the same setup and software, pixelwise ?E profile is determined for the cross-sectional photo of a white EPR specimen, where heterogeneous aging is detected.

cable aging, color analysis↗