Wide field and diffraction limited array camera for SIRTF

The Infrared Array Camera for the space Infrared Telescope Facility (SIRTF/IRAC) is capable of two-dimensional photometry in either a wide field or diffraction-limited mode over the wavelength interval from 2 to 30 microns. Three different two-dimensional direct readout (DRO) array detectors will be used: Band 1-InSb or Si:In (2-5 microns) 128 x 128 pixels, Band 2-Si:Ga (5-18 microns) 64 x 64 pixels, and Band 3-Si:Sb (18-30 microns) 64 x 64 pixels. The hybrid DRO readout architecture has the advantages of low read noise, random pixel access with individual readout rates, and nondestructive readout. The scientific goals of IRAC are discussed, which are the basis for several important requirements and capabilities of the array camera: (1) diffraction-limited resolution from 2-30 microns, (2) use of the maximum unvignetted field of view of SIRTF, (3) simultaneous observations within the three infrared spectral bands, and (4) the capability for broad and narrow bandwidth spectral resolution. A strategy has been developed to minimize the total electronic and environmental noise sources to satisfy the scientific requirements.

Fazio, G. G.↗

Wide field and diffraction limited array camera for SIRTF

The Infrared Array Camera for the Space Infrared Telescope Facility (SIRTF/IRAC) is capable of two-dimensional photometry in either a wide field or diffraction-limited mode over the wavelength interval from 2 to 30 microns. Three different two-dimensional direct readout (DRO) array detectors are being considered: Band 1-InSb or Si:In (2-5 microns) 128 x 128 pixels, Band 2-Si:Ga (5-18 microns) 64 x 64 pixels, and Band 3-Si:Sb (18-30 microns) 64 x 64 pixels. The hybrid DRO readout architecture has the advantages of low read noise, random pixel access with individual readout rates, and nondestructive readout. The scientific goals of IRAC are discussed, which are the basis for several important requirements and capabilities of the array camera: (1) diffraction-limited resolution from 2-30 microns, (2) use of the maximum unvignetted field of view of SIRTF, (3) simultaneous observations within the three infrared spectral bands, and (4) the capability for broad and narrow bandwidth spectral resolution. A strategy has been developed to minimize the total electronic and environmental noise sources to satisfy the scientific requirements.

Fazio, G. G.↗

Four-shooter - A large format charge-coupled device camera for the Hale telescope

The Hale telescope has employed an astronomical camera using four 800x800 CCDs in an optical arrangement that allows the imaging of a contiguous 1600-pixel-square region of the sky; reimaging optics are then used to yield a scale of 0.33 arcsec/pixel. Optical coatings are incorporated to yield a throughput at peak efficiency of nearly 50 percent, including telescope losses. This camera can be used in a scanning mode, in which the telescope tracking rate is offset and the charge is clocked in the chips in such a way that the charge image remains aligned with the optical image. Attention is given to the results of a survey for high-redshift quasars using this equipment, which has produced images for the most distant galaxy clusters yet discovered.

Gunn, James E.↗

Lightweight Video-Camera Head

Compact, lightweight video camera head constructed by remounting lens and charge-coupled-device image detector from small commercial video camera in separate assembly. Useful in robotics, artificial vision, and vision guidance systems. Designed to be mounted on visor of helmet to monitor motions of eyes in experiments on vestibulo-ocular reflexes.

Proctor, David R.↗

Use of a 35mm camera for remote surface cleanliness verification

Non-contact or remote monitoring of surfaces for both particle and molecular contaminants is required for verification of surface cleanliness on many program subsystems. The capability of a 35mm camera to satisfy this need is presented. The many limitations imposed by standard available lens systems are compared to actual required sensitivities. Methods of optimizing camera systems for specific applications and descriptions of support systems for extending the range of usefulness of the recorded data are also provided. Although this general concept is not new, significant improvements in the technique involving the use of polarized light and diffraction effects have resulted in a more efficient utilization of information recorded on the film.

Crutcher, E. R.↗

Design of low noise, high performance X-ray charge-coupled-device cameras

This paper describes some of the critical details of the MIT X-ray CCD camera design. Special attention is given to those portions of the system that deviate from conventional practice in the design of CCD cameras. Furthermore, an attempt has been made to generalize the design so that both optical and X-ray requirements can be satisfied whenever possible. Currently, noise levels of less than 8 electrons rms are routinely achieved with this design, and even lower levels (less than 5 electrons) should be realizable.

Doty, J. P.↗

Full-disk solar Dopplergrams observed with a one-megapixel CCD camera and a sodium magneto-optical filter

The paper presents here the first two full-disk solar Dopplergrams obtained with the new 1024 x 1024-pixel CCD camera which has recently been installed at the 60-Foot Tower Telescope of the Mt. Wilson Observatory. These Dopplergrams have a spatial resolution of 2.2 arcseconds and were obtained in a total of one minute of time. The Dopplergrams were obtained with a magnetooptical filter which was designed to obtain images in the two Na D lines. The filter and the camera were operated together as part of the development of a solar oscillations imager experiment which is currently being designed at JPL for the Joint NASA/ESA Solar and Heliospheric Observatory mission. Two different images obtained by subtracting two pairs of the Dopplergrams from the initial time series are also included.

Rhodes, Edward J., Jr.↗

Hypervelocity impact studies using a rotating mirror framing laser shadowgraph camera

The need to study the effects of the impact of micrometeorites and orbital debris on various space-based systems has brought together the technologies of several companies and individuals in order to provide a successful instrumentation package. A light gas gun was employed to accelerate small projectiles to speeds in excess of 7 km/sec. Their impact on various targets is being studied with the help of a specially designed continuous-access rotating-mirror framing camera. The camera provides 80 frames of data at up to 1 x 10 to the 6th frames/sec with exposure times of 20 nsec.

Parker, Vance C.↗

Experience with the UKIRT InSb array camera

The cryogenic infrared camera, IRCAM, has been operating routinely on the 3.8 m UK Infrared Telescope on Mauna Kea, Hawaii for over two years. The camera, which uses a 62x58 element Indium Antimonide array from Santa Barbara Research Center, was designed and built at the Royal Observatory, Edinburgh which operates UKIRT on behalf of the UK Science and Engineering Research Council. Over the past two years at least 60% of the available time on UKIRT has been allocated for IRCAM observations. Described here are some of the properties of this instrument and its detector which influence astronomical performance. Observational techniques and the power of IR arrays with some recent astronomical results are discussed.

Mclean, Ian S.↗

Initial astronomical results with a new 5-14 micron Si:Ga 58x62 DRO array camera

A new array camera system was developed using a 58 x 62 pixel Si:Ga (gallium doped silicon) DRO (direct readout) photoconductor array detector manufactured by Hughes/Santa Barbara Research Center (SBRC). The camera system is a broad band photometer designed for 5 to 14 micron imaging with large ground-based optical telescopes. In a typical application a 10 micron photon flux of about 10(exp 9) photons sec(exp -1) m(exp -2) microns(exp -1) arcsec(exp -2) is incident in the telescope focal plane, while the detector well capacity of these arrays is 10(exp 5) to 10 (exp 6) electrons. However, when the real efficiencies and operating conditions are accounted for, the 2-channel 3596 pixel array operates with about 1/2 full wells at 10 micron and 10% bandwidth with high duty cycle and no real experimental compromises.

Gezari, Dan↗

Geometric database maintenance using CCTV cameras and overlay graphics

An interactive graphics system using closed circuit television (CCTV) cameras for remote verification and maintenance of a geometric world model database has been demonstrated in GE's telerobotics testbed. The database provides geometric models and locations of objects viewed by CCTV cameras and manipulated by telerobots. To update the database, an operator uses the interactive graphics system to superimpose a wireframe line drawing of an object with known dimensions on a live video scene containing that object. The methodology used is multipoint positioning to easily superimpose a wireframe graphic on the CCTV image of an object in the work scene. An enhanced version of GE's interactive graphics system will provide the object designation function for the operator control station of the Jet Propulsion Laboratory's telerobot demonstration system.

Oxenberg, Sheldon C.↗

Search for atmospheric holes with the Viking cameras

Images taken with the two ultraviolet cameras on board the Viking spacecraft were examined for evidence of transient decreases in the near-nadir dayglow. Comparison of near-limb observations of dayglow intensities with those at smaller angles to the nadir with the camera sensitive to O I 130.4 nm emissions supports the existence of transient decreases in the near-nadir dayglow. However, the amount of near-nadir imaging is severely limited and only several significant events are found.

Frank, L. A.↗

Potential applications of MMC and aluminum-lithium alloys in cameras for CRAF spacecraft

In undertaking the design of a 2000-mm focal length camera for the Mariner Mark II series of spacecraft, JPL sought novel materials with the requisite dimensional and thermal stability, outgassing and corrosion resistance, low mass, high stiffness, and moderate cost. Metal-matrix composites and Al-Li alloys have, in addition to excellent mechanical properties and low density, a suitably low coefficient of thermal expansion, high specific stiffness, and good electrical conductivity. The greatest single obstacle to application of these materials to camera structure design is noted to have been the lack of information regarding long-term dimensional stability.

Lane, Marc↗

Thermal analysis of the ultraviolet imager camera and electronics

The Ultraviolet Imaging experiment has undergone design changes that necessiate updating the reduced thermal models (RTM's) for both the Camera and Electronics. In addition, there are several mission scenarios that need to be evaluated in terms of thermal response of the instruments. The impact of these design changes and mission scenarios on the thermal performance of the Camera and Electronics assemblies is discussed.

Dirks, Gregory J.↗

Analysis of a multiple reception model for processing images from the solid-state imaging camera

A detection model to identify the presence of Galileo optical communications from an Earth-based Transmitter (GOPEX) signal by processing multiple signal receptions extracted from the camera images is described. The model decomposes a multi-signal reception camera image into a set of images so that the location of the pixel being illuminated is known a priori and the laser can illuminate only one pixel at each reception instance. Numerical results show that if effects on the pointing error due to atmospheric refraction can be controlled to between 20 to 30 microrad, the beam divergence of the GOPEX laser should be adjusted to be between 30 to 40 microrad when the spacecraft is 30 million km away from Earth. Furthermore, increasing beyond 5 the number of receptions for processing will not produce a significant detection probability advantage.

Yan, T.-Y.↗

Measurement of surface microtopography using helicopter-mounted stereo film cameras and two stereo matching techniques

A common problem in acquiring ground-truth data for use in microwave interaction modeling is the capture of surface roughness data that are both sampled at distances comparable to a fraction of the wavelength and extensive enough to represent the surface statistics in at least one resolution cell of the microwave remote sensor used. A technique has been developed for acquiring the necessary photogrammetric data using twin 70-mm film cameras mounted on a helicopter boom. The apparatus is described, and the accuracy with which ground surface roughness can be characterized using this device is estimated. Both standard and cross-correlation methods were used for data reduction. Stereogrammetry is compared with a completely automated image-matching technique. Dense disparity images were generated from the helicopter stereo pairs. Using interior orientation parameters supplied by the camera manufacturers, and assuming that exterior orientation parameters remain constant between control target and test field photography, an extremely dense DEM (digital elevation model) for a test field has been derived. Results are compared, and accuracy estimates are presented.

Wall, S. D.↗

Strategy for contamination control to improve Wide-Field/Planetary Camera far-ultraviolet performance

A multifaceted contamination control strategy has been developed for the second generated Wide-Field and Planetary Camera (WFPC-2) to improve the FUV stability by several orders of magnitude, compared to the first camera (WFPC-1). The strategy involves: improved on-orbit boil-off capability of the detector optics, added internal shielding and instrument venting, in-process subassembly vacuum bakeout at elevated temperatures, material substitution, sample testing in ultraclean vacuum facility, and internal instrument contamination-transport modeling. A science performance goal of 1 percent photometric accuracy at 1470 A over an extended time (of at least 30 days) has been established as a contamination control target for WFPC-2. The WFPC-2 is currently planned to be launched by the Shuttle in mid-1993 and replace the WFPC-1 which was recently launched with the HST.

Leschly, Kim↗

Gain, Level, And Exposure Control For A Television Camera

Automatic-level-control/automatic-gain-control (ALC/AGC) system for charge-coupled-device (CCD) color television camera prevents over-loading in bright scenes using technique for measuring brightness of scene from red, green, and blue output signals and processing these into adjustments of video amplifiers and iris on camera lens. System faster, does not distort video brightness signals, and built with smaller components.

Major, Geoffrey J.↗