Search NASA⌕ Search

SEARCH · Search NASA

Results for “camera response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

A First Order Wavefront Estimation Algorithm for P1640 Calibrator

P1640 calibrator is a wavefront sensor working with the P1640 coronagraph and the Palomar 3000 actuator adaptive optics system (P3K) at the Palomar 200 inch Hale telescope. It measures the wavefront by interfering post-coronagraph light with a reference beam formed by low-pass filtering the blocked light from the coronagraph focal plane mask. The P1640 instrument has a similar architecture to the Gemini Planet Imager (GPI) and its performance is currently limited by the quasi-static speckles due to non-common path wavefront errors, which comes from the non-common path for the light to arrive at the AO wavefront sensor and the coronagraph mask. By measuring the wavefront after the coronagraph mask, the non-common path wavefront error can be estimated and corrected by feeding back the error signal to the deformable mirror (DM) of the P3K AO system. Here, we present a first order wavefront estimation algorithm and an instrument calibration scheme used in experiments done recently at Palomar observatory. We calibrate the P1640 calibrator by measuring its responses to poking DM actuators with a sparse checkerboard pattern at different amplitudes. The calibration yields a complex normalization factor for wavefront estimation and establishes the registration of the DM actuators at the pupil camera of the P1640 calibrator, necessary for wavefront correction. Improvement of imaging quality after feeding back the wavefront correction to the AO system demonstrated the efficacy of the algorithm.

Wavefront sensing↗

The Alignment and Phasing System for the Thirty Meter Telescope: Risk Mitigation and Status Update

Alignment and Phasing System (APS) is responsible for the optical alignment via starlight of the approximately 12,000 degrees of freedom of the primary, secondary and tertiary mirrors of Thirty Meter Telescope (TMT). APS is based on the successful Phasing Camera System (PCS) used to align the Keck Telescopes. Since the successful APS conceptual design in 2007, work has concentrated on risk mitigation, use case generation, and alignment algorithm development and improvement. Much of the risk mitigation effort has centered around development and testing of prototype APS software which will replace the current PCS software used at Keck. We present an updated APS design, example use cases and discuss, in detail, the risk mitigation efforts.

Optical Alignment↗

Investigating high speed phenomena in laser plasma interactions using dilation x-ray imager (invited)

The DIlation X-ray Imager (DIXI) is a new, high-speed x-ray framing camera at the National Ignition Facility (NIF) sensitive to x-rays in the range of ≈2–17 keV. DIXI uses the pulse-dilation technique to achieve a temporal resolution of less than 10 ps, a ≈10× improvement over conventional framing cameras currently employed on the NIF (≈100 ps resolution), and otherwise only attainable with 1D streaked imaging. The pulse-dilation technique utilizes a voltage ramp to impart a velocity gradient on the signal-bearing electrons. The temporal response, spatial resolution, and x-ray sensitivity of DIXI are characterized with a short x-ray impulse generated using the COMET laser facility at Lawrence Livermore National Laboratory. At the NIF a pinhole array at 10 cm from target chamber center (tcc) projects images onto the photocathode situated outside the NIF chamber wall with a magnification of ≈64×. DIXI will provide important capabilities for warm-dense-matter physics, high-energy-density science, and inertial confinement fusion, adding important capabilities to temporally resolve hot-spot formation, x-ray emission, fuel motion, and mix levels in the hot-spot at neutron yields of up to 10{sup 17}. We present characterization data as well as first results on electron-transport phenomena in buried-layer foil experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new absolute extreme ultraviolet image system designed for studying the radiated power of the Joint Texas Experimental Tokamak discharges

A bolometer imaging system mounted on different toroidal and poloidal locations used for radiation observation has been developed in the Joint Texas Experimental Tokamak (J-TEXT tokamak). Three miniature pinhole AXUV16ELG (16 elements absolute extreme ultraviolet silicon photodiodes) array cameras, which are settled down in the same toroidal position but in three different poloidal places, can provide a broad viewing angle that covers the whole plasma cross-section, and hence can measure the total radiated power and provide the radiated emissive profile, while nine AXUV10EL (10 elements absolute extreme ultraviolet silicon photodiodes) array cameras are divided into three groups and will be mounted on different toroidal locations to observe the toroidal radiated power distribution. Among these detectors, one element of the AXUV16ELG array is absolutely calibrated by the synchrotron radiation source to verify the system reliability. Although there are some discrepancies between the typical responsivity given by IRD Co. and the calibrated results, it is confirmed that the discrepancies have no major effect on the final result after the simulation. The details of the system as well as observations are presented in the paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MEASURING HIGH-PRECISION ASTROMETRY WITH THE INFRARED ARRAY CAMERA ON THE SPITZER SPACE TELESCOPE

The Infrared Array Camera (IRAC) on the Spitzer Space Telescope currently offers the greatest potential for high-precision astrometry of faint mid-IR sources across arcminute-scale fields, which would be especially valuable for measuring parallaxes of cold brown dwarfs in the solar neighborhood and proper motions of obscured members of nearby star-forming regions. To more fully realize IRAC's astrometric capabilities, we have sought to minimize the largest sources of uncertainty in astrometry with its 3.6 and 4.5 μm bands. By comparing different routines that estimate stellar positions, we have found that Point Response Function (PRF) fitting with the Spitzer Science Center's Astronomical Point Source Extractor produces both the smallest systematic errors from varying intra-pixel sensitivity and the greatest precision in measurements of positions. In addition, self-calibration has been used to derive new 7th and 8th order distortion corrections for the 3.6 and 4.5 μm arrays of IRAC, respectively. These corrections are suitable for data throughout the mission of Spitzer when a time-dependent scale factor is applied to the corrections. To illustrate the astrometric accuracy that can be achieved by combining PRF fitting with our new distortion corrections, we have applied them to archival data for a nearby star-forming region, arriving at total astrometric errors of ∼20 and 70 mas at signal to noise ratios of 100 and 10, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

Search for the Pygmy Dipole Resonance in {sup 68}Ni at 600 MeV/nucleon

The {gamma} decay from Coulomb excitation of {sup 68}Ni at 600 MeV/nucleon on a Au target was measured using the RISING setup at the fragment separator of GSI. The {sup 68}Ni beam was produced by a fragmentation reaction of {sup 86}Kr at 900 MeV/nucleon on a {sup 9}Be target and selected by the fragment separator. The {gamma} rays produced at the Au target were measured with HPGe detectors at forward angles and with BaF{sub 2} scintillators at backward angles. The measured spectra show a peak centered at approximately 11 MeV, whose intensity can be explained in terms of an enhanced strength of the dipole response function (pygmy resonance). Such pygmy structure has been predicted in this unstable neutron-rich nucleus by theory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Feasibility of Motion Tracking Camera System for Magnetic Suspension Wind Tunnel Tests

The Entry Systems Modeling (ESM) Program at NASA has actively participated in the re-development of the Magnetic Suspension Balance System (MSBS) at the six-inch subsonic wind tunnel at NASA Langley Research Center. This initiative aims to enhance the MSBS system's capabilities, enabling the testing of stingless entry vehicle models at supersonic speeds. To achieve this, control algorithms are required to ensure magnetic levitation control and stability for models during free-oscillation dynamic responses. Currently, the system relies on electromagnetic position sensors to provide real-time 3 degrees of freedom in a rigid body. While this approach has proven successful for subsonic speeds, expanding testing under higher pressure conditions may necessitate the incorporation of real-time roll and pitch measurements to quantify the dynamic stability characteristics of the models in free-oscillation. In collaboration with Old Dominion University, the team at NASA Langley Research Center proposes the implementation of a motion-tracking camera system. This system will provide real-time five degrees of freedom output, which will be utilized within a closed feedback control system and a two-step system identification model to isolate aerodynamic forces from their corresponding magnetic forces. The motion-tracking cameras will offer precise and accurate control over the levitation system, facilitating precise and repeatable experiments within the wind tunnel. The real-time feedback provided by the cameras enables prompt adjustments to ensure the maintenance of stable levitation throughout the testing process.

Entry Systems Modeling↗

The Feasibility of Motion Tracking Camera System for Magnetic Suspension Wind Tunnel Tests

The Entry Systems Modeling (ESM) Program at NASA has actively participated in the re-development of the Magnetic Suspension Balance System (MSBS) at the six-inch subsonic wind tunnel at NASA Langley Research Center. This initiative aims to enhance the MSBS system's capabilities, enabling the testing of stingless entry vehicle models at supersonic speeds. To achieve this, control algorithms are required to ensure magnetic levitation control and stability for models during free-oscillation dynamic responses. Currently, the system relies on electromagnetic position sensors to provide real-time 3 degrees of freedom in a rigid body. While this approach has proven successful for subsonic speeds, expanding testing under higher pressure conditions may necessitate the incorporation of real-time roll and pitch measurements to quantify the dynamic stability characteristics of the models in free-oscillation. In collaboration with Old Dominion University, the team at NASA Langley Research Center proposes the implementation of a motion-tracking camera system. This system will provide real-time five degrees of freedom output, which will be utilized within a closed feedback control system and a two-step system identification model to isolate aerodynamic forces from their corresponding magnetic forces. The motion-tracking cameras will offer precise and accurate control over the levitation system, facilitating precise and repeatable experiments within the wind tunnel. The real-time feedback provided by the cameras enables prompt adjustments to ensure the maintenance of stable levitation throughout the testing process.

Entry Systems Modeling↗

Is flat fielding safe for precision CCD astronomy?

The ambitious goals of precision cosmology with wide-field optical surveys such as the Dark Energy Survey (DES) and the Large Synoptic Survey Telescope (LSST) demand precision CCD astronomy as their foundation. This in turn requires an understanding of previously uncharacterized sources of systematic error in CCD sensors, many of which manifest themselves as static effective variations in pixel area. Such variation renders a critical assumption behind the traditional procedure of flat fielding—that a sensor's pixels comprise a uniform grid—invalid. In this work, we present a method to infer a curl-free model of a sensor's underlying pixel grid from flat-field images, incorporating the superposition of all electrostatic sensor effects—both known and unknown—present in flat-field data. We use these pixel grid models to estimate the overall impact of sensor systematics on photometry, astrometry, and PSF shape measurements in a representative sensor from the Dark Energy Camera (DECam) and a prototype LSST sensor. Applying the method to DECam data recovers known significant sensor effects for which corrections are currently being developed within DES. For an LSST prototype CCD with pixel-response non-uniformity (PRNU) of 0.4%, we find the impact of "improper" flat fielding on these observables is negligible in nominal .7'' seeing conditions. Furthermore, these errors scale linearly with the PRNU, so for future LSST production sensors, which may have larger PRNU, our method provides a way to assess whether pixel-level calibration beyond flat fielding will be required.

79 ASTRONOMY AND ASTROPHYSICS↗

Single-Volume Neutron Scatter Camera for High-Efficiency Neutron Imaging and Source Characterization. Year 2 of 3 Summary

The neutron scatter camera (NSC), an imaging spectrometer for fission energy neutrons, is an established and proven detector for nuclear security applications such as weak source detection of special nuclear material (SNM), arms control treaty verification, and emergency response. Relative to competing technologies such as coded aperture imaging, time-encoded imaging, neutron time projection chamber, and various thermal neutron imagers, the NSC provides excellent event-by-event directional information for signal/background discrimination, reasonable imaging resolution, and good energy resolution. Its primary drawback is very low detection efficiency due to the requirement for neutron elastic scatters in two detector cells. We will develop a singlevolume double-scatter neutron imager, in which both neutron scatters can occur in the same large active volume. If successful, the efficiency will be dramatically increased over the current NSC cell-based geometry. If the detection efficiency approaches that of e.g. coded aperture imaging, the other inherent advantages of double-scatter imaging would make it the most attractive fast neutron detector for a wide range of security applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

KidSat: Image User's Manual

The goal of KidSat was to provide young students with the opportunity to participate directly in the NASA space program and to enhance learning in the process. The KidSat pilot project was focused on using a color digital camera, mounted on the space shuttle, to take pictures of the Earth. These could be used to enhance middle school curricula. The project not only benefited middle school students, who were essentially the Science Team, responsible for deciding where to take pictures, but it also benefited high school students and undergraduates, who were essentially the Project Team, responsible for the development and implementation of the project. KidSat flew on three missions as part of the pilot project: STS-76, STS-81, and STS-86. This document describes the goals, project elements, results, and data for the three KidSat missions that made up the pilot program. It serves as a record for this pilot project and may be used as a reference for similar projects. It can also be a too] in using the data to its fullest extent. The KidSat Web page remains on-line at http://kidsat.jpl.nasa.gov/kidsat, and the images may be downloaded in their full resolution.

Way, JoBea↗

Calculation of spatial response of 2D beam emission spectroscopy diagnostic on MAST

The beam emission spectroscopy (BES) turbulence diagnostic on MAST is to be upgraded in June 2010 from a one-dimensional trial system to a two-dimensional imaging system (8 radialx4 poloidal channels) based on a newly developed avalanche photodiode array camera. The spatial resolution of the new system is calculated in terms of the point spread function to account for the effects of field-line curvature, observation geometry, the finite lifetime of the excited state of the beam atoms, and beam attenuation and divergence. It is found that the radial spatial resolution is {approx}2-3 cm and the poloidal spatial resolution {approx}1-5 cm depending on the radial viewing location. The absolute number of detected photons is also calculated, hence the photon noise level can be determined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Overview of new MAST physics in anticipation of first results from MAST Upgrade

We report that the mega amp spherical tokamak (MAST) was a low aspect ratio device (R/a = 0.85/0.65 ~ 1.3) with similar poloidal cross-section to other medium-size tokamaks. The physics programme concentrates on addressing key physics issues for the operation of ITER, design of DEMO and future spherical tokamaks by utilising high resolution diagnostic measurements closely coupled with theory and modelling to significantly advance our understanding. An empirical scaling of the energy confinement time that favours higher power, lower collisionality devices is consistent with gyrokinetic modelling of electron scale turbulence. Measurements of ion scale turbulence with beam emission spectroscopy and gyrokinetic modelling in up-down symmetric plasmas find that the symmetry of the turbulence is broken by flow shear. Near the non-linear stability threshold, flow shear tilts the density fluctuation correlation function and skews the fluctuation amplitude distribution. Results from fast particle physics studies include the observation that sawteeth are found to redistribute passing and trapped fast particles injected from neutral beam injectors in equal measure, suggesting that resonances between the m = 1 perturbation and the fast ion orbits may be playing a dominant role in the fast ion transport. Measured D–D fusion products from a neutron camera and a charged fusion product detector are 40% lower than predictions from TRANSP/NUBEAM, highlighting possible deficiencies in the guiding centre approximation. Modelling of fast ion losses in the presence of resonant magnetic perturbations (RMPs) can reproduce trends observed in experiments when the plasma response and charge-exchange losses are accounted for. Measurements with a neutral particle analyser during merging-compression start-up indicate the acceleration of ions and electrons. Transport at the plasma edge has been improved through reciprocating probe measurements that have characterised a geodesic acoustic mode at the edge of an ohmic L-mode plasma and particle-in-cell modelling has improved the interpretation of plasma potential estimates from ball-pen probes. The application of RMPs leads to a reduction in particle confinement in L-mode and H-mode and an increase in the core ionization source. The ejection of secondary filaments following type-I ELMs correlates with interactions with surfaces near the X-point. Simulations of the interaction between pairs of filaments in the scrape-off layer suggest this results in modest changes to their velocity, and in most cases can be treated as moving independently. A stochastic model of scrape-off layer profile formation based on the superposition of non-interacting filaments is in good agreement with measured time-average profiles. Transport in the divertor has been improved through fast camera imaging, indicating the presence of a quiescent region devoid of filament near the X-point, extending from the separatrix to $ψ_n$ ~ 1.02. Simulations of turbulent transport in the divertor show that the angle between the divertor leg on the curvature vector strongly influences transport into the private flux region via the interchange mechanism. Coherence imaging measurements show counter-streaming flows of impurities due to gas puffing increasing the pressure on field lines where the gas is ionised. MAST Upgrade is based on the original MAST device, with substantially improved capabilities to operate with a Super-X divertor to test extended divertor leg concepts. SOLPS-ITER modelling predicts the detachment threshold will be reduced by more than a factor of 2, in terms of upstream density, in the Super-X compared with a conventional configuration and that the radiation front movement is passively stabilised before it reaches the X-point. 1D fluid modelling reveals the key role of momentum and power loss mechanisms in governing detachment onset and evolution. Analytic modelling indicates that long legs placed at large major radius, or equivalently low at the target compared with the X-point are more amenable to external control. With MAST Upgrade experiments expected in 2019, a thorough characterisation of the sources of the intrinsic error field has been carried out and a mitigation strategy developed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Augmented reality to guide pedestrian evacuation in earthquake events

Augmented Reality is a promising technology to support safe pedestrian evacuation from buildings during earthquakes. The widespread availability of phone cameras makes this idea feasible. QR codes, for instance, can place virtual three-dimensional objects to guide people along a prescribed route. In this work, a prototypical system based on this premise was created in response to the 2020 sudden surge in seismic activity in Puerto Rico. The results point towards feasibility as well as to a series of areas that require improvement for a real-life implementation.

Rivera-Hernández, Diego F.↗

Imaging experiment - The Viking Mars Orbiter.

The general objectives of the imaging experiment on the Viking Orbiter are to aid the selection of Viking Lander sites, to map and monitor the chosen sites during lander operations, to aid in the selection of future landing sites, and to extend our knowledge of the planet. The imaging system consists of two identical vidicon cameras each attached to a 1026-mm T/8 telescope giving approximately 1-deg square field of view. From an altitude of 1500 km, the picture elements will be approximately 24 m apart. The vidicon is coupled with an image intensifier which provides increased sensitivity and permits electronic shuttering and image motion compensation. The camera differs from those previously flown to Mars by providing contiguous coverage at high resolution on a single orbital pass, by having sufficient sensitivity to use narrow band color filters at maximum resolution, and by having response in the ultraviolet.

Carr, M. H.↗

Generation of animation sequences of three dimensional models

The invention is directed toward a method and apparatus for generating an animated sequence through the movement of three-dimensional graphical models. A plurality of pre-defined graphical models are stored and manipulated in response to interactive commands or by means of a pre-defined command file. The models may be combined as part of a hierarchical structure to represent physical systems without need to create a separate model which represents the combined system. System motion is simulated through the introduction of translation, rotation and scaling parameters upon a model within the system. The motion is then transmitted down through the system hierarchy of models in accordance with hierarchical definitions and joint movement limitations. The present invention also calls for a method of editing hierarchical structure in response to interactive commands or a command file such that a model may be included, deleted, copied or moved within multiple system model hierarchies. The present invention also calls for the definition of multiple viewpoints or cameras which may exist as part of a system hierarchy or as an independent camera. The simulated movement of the models and systems is graphically displayed on a monitor and a frame is recorded by means of a video controller. Multiple movement and hierarchy manipulations are then recorded as a sequence of frames which may be played back as an animation sequence on a video cassette recorder.

Poi, Sharon↗

Methods for LWIR Radiometric Calibration and Characterization

The utility of a remote sensing system increases with its ability to retrieve surface temperature or radiance accurately. Research applications, such as sea temperature and power plant discharge, require a 0.2 C resolution or better for absolute temperature retrievals. Other applications, including agriculture water stress detection, require at least a 1 C resolution. To achieve these levels of accuracy routinely, scientists must perform laboratory and onboard calibration, as well as in-flight vicarious radiometric characterization. A common approach used for in-flight radiometric characterization incorporates a well-calibrated infrared radiometer that is mounted on a bouy and placed on a uniform water body. The radiometer monitors radiant temperature along with pressure, humidity, and temperature measurements of an associated column of atmosphere. On very still waters, however, a buoy can significantly distrub these measurements. Researchers at NASA's Stennis Space Center (SSC) have developed a novel approach of using an uncooled infrared camera mounted on a boom to quantify buoy effects. Another critical aspect of using buoy-mounted infrared radiometers is the need for extensive laboratory characterization of the instruments' radiometric sensitivity, field of view, and spectral response. Proper surface temperature retrieval also requires detailed knowledge of both the upward emission and the reflected sky emission. Recent work at SSC has demonstrated that the use of a polarization-based radiometer operating at the Brewster angle can greatly simplify temperature retrieval as well as improve overall accuracy.

Ryan, Robert↗

Modal Analysis and Model Correlation of the Mir Space Station

This paper will discuss on-orbit dynamic tests, modal analysis, and model refinement studies performed as part of the Mir Structural Dynamics Experiment (MiSDE). Mir is the Russian permanently manned Space Station whose construction first started in 1986. The MiSDE was sponsored by the NASA International Space Station (ISS) Phase 1 Office and was part of the Shuttle-Mir Risk Mitigation Experiment (RME). One of the main objectives for MiSDE is to demonstrate the feasibility of performing on-orbit modal testing on large space structures to extract modal parameters that will be used to correlate mathematical models. The experiment was performed over a one-year span on the Mir-alone and Mir with a Shuttle docked. A total of 45 test sessions were performed including: Shuttle and Mir thruster firings, Shuttle-Mir and Progress-Mir dockings, crew exercise and pushoffs, and ambient noise during night-to-day and day-to-night orbital transitions. Test data were recorded with a variety of existing and new instrumentation systems that included: the MiSDE Mir Auxiliary Sensor Unit (MASU), the Space Acceleration Measurement System (SAMS), the Russian Mir Structural Dynamic Measurement System (SDMS), the Mir and Shuttle Inertial Measurement Units (IMUs), and the Shuttle payload bay video cameras. Modal analysis was performed on the collected test data to extract modal parameters, i.e. frequencies, damping factors, and mode shapes. A special time-domain modal identification procedure was used on free-decay structural responses. The results from this study show that modal testing and analysis of large space structures is feasible within operational constraints. Model refinements were performed on both the Mir alone and the Shuttle-Mir mated configurations. The design sensitivity approach was used for refinement, which adjusts structural properties in order to match analytical and test modal parameters. To verify the refinement results, the analytical responses calculated using original and refined math models were compared with the measured responses. The results from this study show that the refined models predict more accurately the dynamics of the actual structure. The MiSDE test and analysis results provided the information and experience on test design, flight testing, and data analysis for the ISS and other future spacecraft, which are critical to the verification of analytical models and structural loads.

Kim, Hyoung M.↗