Search NASA⌕ Search

SEARCH · Search NASA

Results for “capacity value”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

High Capacity Adsorption—Dominated Potassium and Sodium Ion Storage in Activated Crumpled Graphene

In this study, structurally and chemically defective activated-crumbled graphene (A-CG) is employed to achieve unique synergy of large reversible potassium (K) and sodium (Na) ion storage capacity with fast charging and extended cyclability. A-CG synthesis consists of low temperature spraying of graphene oxide slurry, followed by partial reduction annealing and air activation. For K storage, the reversible capacities are 340 mAh g -1 at 0.04 A g -1 , 261 mAh g -1 at 0.5 A g -1 , and 210 mAh g -1 at 2 A g -1 . For Na storage, the reversible capacities are 280 mAh g -1 at 0.04 A g -1 , 191 mAh g -1 at 0.5 A g -1 , and 151 mAh g -1 at 2 A g -1 . A-CG shows a stable intermediate rate (0.5 Ag -1 ) cycling with both K and Na, with minimal fade after 2800 and 8000 cycles. These are among the most favorable capacity—rate capability—cyclability combinations recorded for potassium-ion battery and sodium-ion battery carbons. Electroanalytical studies (cyclic voltammetry, galvanostatic intermittent titration technique, b -value) and density functional theory (DFT) reveal that enhanced electrochemical performance originates from ion adsorption at various defects, such as Stone–Wales defects. Moreover, DFT highlights enhanced thermodynamic stability of A-CG with adsorbed K versus with adsorbed Na, explaining the unexpected higher reversible capacity with the former.

25 ENERGY STORAGE↗

An Air Revitalization Model (ARM) for Regenerative Life Support Systems (RLSS)

The primary objective of the air revitalization model (ARM) is to determine the minimum buffer capacities that would be necessary for long duration space missions. Several observations are supported by the current configuration sizes: the baseline values for each gas and the day to day or month to month fluctuations that are allowed. The baseline values depend on the minimum safety tolerances and the quantities of life support consumables necessary to survive the worst case scenarios within those tolerances. Most, it not all, of these quantities can easily be determined by ARM once these tolerances are set. The day to day fluctuations also require a command decision. It is already apparent from the current configuration of ARM that the tighter these fluctuations are controlled, the more energy used, the more nonregenerable hydrazine consumed, and the larger the required capacities for the various gas generators. All of these relationships could clearly be quantified by one operational ARM.

Hart, Maxwell M.↗

Effects of Control Mode and R-Ratio on the Fatigue Behavior of a Metal Matrix Composite

Composite Because of their high specific stiffness and strength at elevated temperatures, continuously reinforced metal matrix composites (MMC's) are under consideration for a future generation of aeropropulsion systems. Since components in aeropropulsion systems experience substantial cyclic thermal and mechanical loads, the fatigue behavior of MMC's is of great interest. Almost without exception, previous investigations of the fatigue behavior of MMC's have been conducted in a tension-tension, load-controlled mode. This has been due to the fact that available material is typically less than 2.5-mm thick and, therefore, unable to withstand high compressive loads without buckling. Since one possible use of MMC's is in aircraft skins, this type of testing mode may be appropriate. However, unlike aircraft skins, most engine components are thick. In addition, the transient thermal gradients experienced in an aircraft engine will impose tension-compression loading on engine components, requiring designers to understand how the MMC will behave under fully reversed loading conditions. The increased thickness of the MMC may also affect the fatigue life. Traditionally, low-cycle fatigue (LCF) tests on MMC's have been performed in load control. For monolithic alloys, low-cycle fatigue tests are more typically performed in strain control. Two reasons justify this choice: (1) the critical volume from which cracks initiate and grow is generally small and elastically constrained by the larger surrounding volume of material, and (2) load-controlled, low-cycle fatigue tests of monolithics invariably lead to unconstrained ratcheting and localized necking--an undesired material response because the failure mechanism is far more severe than, and unrelated to, the fatigue mechanism being studied. It is unknown if this is the proper approach to composite testing. However, there is a lack of strain-controlled data on which to base any decisions. Consequently, this study addresses the isothermal, LCF behavior of a [0]_32 MMC tested under strain- and load-controlled conditions for both zero-tension and tension-compression loading conditions. These tests were run at 427 C on thick specimens of SiC-reinforced Ti-15-3. For the fully-reversed tests, no difference was observed in the lives between the load- and strain-controlled tests. However, for the zero-tension tests, the strain-controlled tests had longer lives by a factor of 3 in comparison to the load-controlled tests. This was due to the fact that under strain-control the specimens cyclically softened, reducing the cracking potential. In contrast, the load-controlled tests ratcheted toward larger tensile strains leading to an eventual overload of the fibers. Fatigue tests revealed that specimens tested under fully-reversed conditions had lives approximately an order of magnitude longer than for those specimens tested under zero tension. When examined on a strain-range basis, the fully reversed specimens had similar, but still shorter lives than those of the unreinforced matrix material. However, the composite had a strain limitation at short lives because of the limited strain capacity of the brittle ceramic fiber. The composite also suffered at very high lives because of the lack of an apparent fatigue limit in comparison to the unreinforced matrix. The value of adding fibers to the matrix is apparent when the fatigue lives are plotted as a function of stress range. Here, the composite is far superior to the unreinforced matrix because of the additional load-carrying capacity of the fibers.

Source record↗

First-principles study on the mechanical and thermodynamic properties of MoNbTaTiW

Refractory high-entropy alloys (RHEAs) are emerging as new materials for high temperature structural applications because of their stable mechanical and thermal properties at temperatures higher than 2273 K. In this study, the mechanical properties of MoNbTaTiW REDEA are examined by applying calculations based on first-principles density functional theory (DFT) and using a large unit cell with 100 randomized atoms. The phase calculation of MoNbTaTiW with CALPHAD method shows the existence of a stable body-centered cubic structure at a high temperature and a hexagonal closely packed phase at a low temperature. The predicted phase, shear modulus, Young’s modulus, Poisson’s ratio, and hardness values are consistent with available experimental results. The linear thermal expansion coefficient, vibrational entropy, and vibrational heat capacity of MoNbTaTiW RHEA are investigated in accordance with Debye-Grüneisen theory. These results may provide a basis for future research related to the application of RHEAs.

36 MATERIALS SCIENCE↗

Development of CuFeMnAlO 4+δ oxygen carrier with high attrition resistance and 50-kWth methane/air chemical looping combustion tests

A Copper-Ferri-Manganese-Aluminate spinel (CuFeMnAlO 4+δ ) oxygen carrier, developed at the US Department of Energy’s (DOE) National Energy Technology Laboratory (NETL), shows promising results for chemical looping combustion with methane. Attrition resistance of the spinel oxygen carrier (160–600 µm) produced by a wet agglomeration method was significantly higher than that observed previously with a Copper-Ferri-Aluminate (CuFeAlO 4 ) oxygen carrier. Improved attrition resistance of the novel carrier can be attributed to minimal alumina phase segregation and minimal carbon formation. Heats of reaction measured by differential scanning calorimetry indicated exothermicity during reduction with methane. The total oxygen transfer capacity of the material was about 10.5 wt% at 850 °C. The attrition resistance and the oxygen transfer capacity of the carrier prepared at a commercial manufacturing facility (180 kg) were very similar to observed values during the development phase with the lab scale preparations. The material displays satisfactory methane conversion and significantly high particle durability during a 54 h test campaign conducted in NETL’s 50-kWth chemical looping dual fluid bed reactor unit at temperatures ranging from 700 to 900 °C. Low oxygen carrier make-up cost, due to the use of natural ore and pigment grade raw materials during synthesis and very low attrition rates, exceeded the performance goals determined by systems studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pool boiling critical heat flux studies of accident tolerant fuel cladding materials

Pool boiling experiments have been performed at atmospheric pressure on potential accident tolerant fuel (ATF) cladding materials (Zirlo®, Cr coated Zirlo®, FeCrAl coated Zirlo®, and monolithic SiC) to evaluate the Critical Heat Flux (CHF) points. Corrosion resistant coatings of Cr and FeCrAl alloy were deposited on flat Zirlo® samples using cold spray technology. The as-prepared samples after uniform surface polishing were subjected to autoclave tests at 360 °C water and 18.6 MPa for 360 h to simulate prototypic corrosion of the ATF cladding materials in LWR normal operation. Surface characteristics potentially influencing CHF such as surface morphology, roughness, static contact angle, and surface chemistry were characterized using a suite of characterization methods including scanning electron microscopy, 3D optical profilometry, optical contact angle measurements, and x-ray photoelectron spectroscopy (XPS). Thermo-physical properties of the samples such as density, thermal conductivity, and heat capacity were measured by differential scanning calorimetry and laser flash thermal diffusivity measurement. FeCrAl coatings showed CHF values comparable to bare Zirlo® samples, while slightly lower CHF values were observed for Cr coated samples and bulk SiC flats (produced by chemical vapor deposition, CVD). As-deposited Cr coatings showed 67% higher CHF than the as-polished Cr coatings due to its higher surface roughness level. The autoclave testing for the prepared samples generally increased the CHF except for the surface polished Cr coatings. Similar CHF values of bare Zirlo®, FeCrAl coating, and CVD SiC samples were observed after autoclave test but there were negligible change CHF of Cr coatings. XPS studies indicated that the formation or deposition of a few monolayers of hydrophobic carbonaceous species on surface can affect CHF values. The trends in CHF data are discussed in terms of evolution of the surface characteristics of the ATF materials.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Metal–organic frameworks as O 2 -selective adsorbents for air separations

Oxygen is a critical gas in numerous industries and is produced globally on a gigatonne scale, primarily through energy-intensive cryogenic distillation of air. The realization of large-scale adsorption-based air separations could enable a significant reduction in associated worldwide energy consumption and would constitute an important component of broader efforts to combat climate change. Certain small-scale air separations are carried out using N 2 -selective adsorbents, although the low capacities, poor selectivities, and high regeneration energies associated with these materials limit the extent of their usage. In contrast, the realization of O 2 -selective adsorbents may facilitate more widespread adoption of adsorptive air separations, which could enable the decentralization of O 2 production and utilization and advance new uses for O 2 . Here, we present a detailed evaluation of the potential of metal–organic frameworks (MOFs) to serve as O 2 -selective adsorbents for air separations. Drawing insights from biological and molecular systems that selectively bind O 2 , we survey the field of O 2 -selective MOFs, highlighting progress and identifying promising areas for future exploration. As a guide for further research, the importance of moving beyond the traditional evaluation of O 2 adsorption enthalpy, ΔH, is emphasized, and the free energy of O 2 adsorption, ΔG, is discussed as the key metric for understanding and predicting MOF performance under practical conditions. Based on a proof-of-concept assessment of O 2 binding carried out for eight different MOFs using experimentally derived capacities and thermodynamic parameters, we identify two existing materials and one proposed framework with nearly optimal ΔG values for operation under user-defined conditions. While enhancements are still needed in other material properties, the insights from the assessments herein serve as a guide for future materials design and evaluation. Computational approaches based on density functional theory with periodic boundary conditions are also discussed as complementary to experimental efforts, and new predictions enable identification of additional promising MOF systems for investigation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring the Grid Value Potential of Offshore Wind Energy in Oregon

The grid value of Oregon's offshore wind resource is considered through the lenses of (i) resource complementarity with the hydroelectric system and other Variable Renewable Energy resources, (ii) load complementarity with the four balancing authorities with territory in Oregon, and (iii) spatial value to regional and coastal grids as represented through a Production Cost Model of the WECC system. Capacity implications of the interactions between offshore wind and the historical east-to-west power flows of the region are reviewed. The existing system is shown to accommodate 2GW of offshore wind interconnections without curtailment.

17 WIND ENERGY↗

Developing a Framework for Valuation of Grid Services

The electric system is rapidly evolving and growing, raising new questions about how to define and value grid services delivered by a diverse set of resources, including customer-owned assets. This report advances a service–parameter–value framework that links what a grid service does to why it matters, and how its benefits are evidenced. We build upon prior efforts (Bender et al. 2021) and extend them to include value categories (reliability, resilience, cost & access, and security) with primary and secondary tiers, service-specific value streams that explain how benefits materialize, and metrics that make valuation traceable and comparable. We apply the framework to the six core grid services defined in (Kolln et al. 2023): Frequency Response, Regulation, Reserves, Energy, Voltage Management, and Blackstart and demonstrate it on three use cases to highlight the adaptability of these value streams. Further, we outline how the framework integrates with existing tools such as asset optimization, hosting capacity and cost-benefit analysis, and propose a path to portable qualifications and consistent stacking rules for use in tariffs and filings. Finally, we identify future pathways for research and application research needs to support standardization and decision-ready comparisons across services, assets, and architectures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermal Cooling Water Datasets for Electric Sector Modeling

This spreadsheet contains data inputs associated with representations of water (i.e., use, supply, costs) for thermo-electric based production. Values in this spreadsheet have been used to support multiple transmission-related planning studies, using models such as Regional Energy Deployment System Model (ReEDS). More information about associated studies can be found in Miara et al., 2019 (DOI: 10.1021/acs.est.9b03037); Cohen et al., 2022 (DOI: 10.1016/j.apenergy.2022.119193); and Cohen et al., 2024 (DOI TBD). Within these transmission-related studies, the values present in this spreadsheet are assigned for simulation of both existing units as well as new capacity build-outs. A summary of worksheets' content as well as associated sources are captured below.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Diffusing capacity and anatomic dead space for carbon-18 monoxide.

Carbon monoxide (CO) is difficult to measure with a respiratory mass spectrometer because of the similar mass numbers of CO and nitrogen, but this is possible using carbon-18 monoxide. The mass resolution, signal-to-noise ratio, linearity, and background were all found to be adequate. The measurement of the single-breath diffusing capacity was examined. Unless the mean alveolar volume during breath holding is used in the calculation, the value for Dco obtained depends on which portion of the alveolar sample is analyzed. The anatomic dead space for CO was found to be almost the same as that for argon suggesting that the diffusion rate at the dead space-alveolar gas interface was not greatly affected by the alveolar concentration of the gas.

Wagner, P. D.↗

Study on spectral/radiometric characteristics of the Thematic Mapper for land use applications

An information theoretic measure of multispectral information content is developed and applied to a simultaneous LANDSAT TM and MSS data set. The entropy based function measures the dispersion and concentration of signal values in various data spaces, irrespective of specific class memberships. It is used to compare the information content of TM and MSS and of various subsets of TM and MSS bans, as well as tasseled cap transformations of the band values. Differences exist between the information measure results and results using variance based measures. System design information capacities and data space volumes are also compared. The results and observations presented are considered preliminary in nature since only one real and one simulated data set are analyzed.

Malila, W. A.↗

A simple, first step to the optimization of regenerator geometry

This paper presents a simplified set of equations for calculating and optimizing regenerator geometries. A number of competing parameters must be accounted for in the design of a regenerator. To obtain high values of effectiveness, there is need for a large surface area for heat transfer and high heat capacity. The void volume should be small to maintain the pressure ratio in the entire system. Moreover, the pressure drop should be small compared to the absolute pressure. With the assumptions made here, the calculations can be done with a hand calculator. The equations show that the optimum regenerator length, hydraulic radius, and porosity are independent of mass flow rate and the gas cross sectional area is proportional to the mass flow rate. It is shown that using gas gaps between parallel plates produces a significantly better regenerator than is possible with packed spheres or screens, particularly at temperatures below approximately 50%.

Radebaugh, R.↗

Thermal properties and effects for Li/BCX (thionyl chloride) cells

New NASA requirements for the screening of lithium cells for space applications involve thermal soaks at elevated temperatures (149 C). The currently qualified Li/BCX cells and three design modifications have been evaluated showing that a design incorporating a shortened electrode stack met this test condition while continuing to satisfy the performance and safety requirements for cells used on NASA manned space vehicles. Information was also developed to show that measured heat capacities for the BCX D size cells correlated well with the heat generated from cells discharged in an insulated environment. Calculated heat capacities based on the amounts and types of materials in a cell were low compared to these values. This information provides the basis for the design of battery packs in the highly insulating environment of outer space.

Takeuchi, E. S.↗

Unified micromechanics of damping for unidirectional and off-axis fiber composites

An integrated micromechanics methodology for the prediction of damping capacity in fiber-reinforced polymer matrix unidirectional composites has been developed. Explicit micromechanics equations based on hysteretic damping are presented relating the on-axis damping capacities to the fiber and matrix properties and fiber volume ratio. The damping capacities of unidirectional composites subjected to off-axis loading are synthesized from on-axis damping values. Predicted values correlate satisfactorily with experimental measurements. The hygro-thermal effect on the damping performance of unidirectional composites caused by temperature and moisture variations is also modeled. The damping contributions from interfacial friction between broken fibers and matrix are incorporated. Finally, the temperature rise in continuously vibrating composite plies is estimated. Application examples illustrate the significance of various parameters on the damping performance of unidirectional and off-axis fiber reinforced composites.

Saravanos, Dimitris A.↗

ICAN/DAMP-integrated composite analyzer with damping analysis capabilities: User's manual

This manual describes the use of the computer code ICAN/DAMP (Integrated Composite Analyzer with Damping Analysis Capabilities) for the prediction of damping in polymer-matrix composites. The code is written in FORTRAN 77 and is a version of the ICAN (Integrated Composite ANalyzer) computer program. The code incorporates a new module for synthesizing the material damping from micromechanics to laminate level. Explicit micromechanics equations based on hysteretic damping are programmed relating the on-axis damping capacities to the fiber and matrix properties and fiber volume ratio. The damping capacities of unidirectional composites subjected to off-axis loading are synthesized from on-axis damping values. The hygrothermal effect on the damping performance of unidirectional composites caused by temperature and moisture variation is modeled along with the damping contributions from interfacial friction between broken fibers and matrix. The temperature rise is continuously vibrating composite plies and composite laminates is also estimated. The ICAN/DAMP user's manual provides descriptions of the damping analysis module's functions, structure, input requirements, output interpretation, and execution requirements. It only addresses the changes required to conduct the damping analysis and is used in conjunction with the 'Second Generation Integrated Composite Analyzer (ICAN) Computer Code' user's manual (NASA TP-3290).

Saravanos, Dimitrious A.↗

Program For Joule-Thomson Analysis Of Mixed Cryogens

JTMIX computer program predicts ideal and realistic properties of mixed gases at temperatures between 65 and 80 K. Performs Joule-Thomson analysis of any gaseous mixture of neon, nitrogen, various hydrocarbons, argon, oxygen, carbon monoxide, carbon dioxide, and hydrogen sulfide. When used in conjunction with DDMIX computer program of National Institute of Standards and Technology (NIST), JTMIX accurately predicts order-of-magnitude increases in Joule-Thomson cooling capacities occuring when various hydrocarbons added to nitrogen. Also predicts boiling temperature of nitrogen depressed from normal value to as low as 60 K upon addition of neon. Written in Turbo C.

Jones, Jack A.↗

Addressing Failures in Molten Salt Thermal Energy Storage Tank for Central Receiver Concentrating Solar Power Plants

The thermal energy storage (TES) system is a critical component in concentrated solar power (CSP) plants that increases the plant's capacity factor and economic competitiveness by reducing the levelized cost of energy (LCOE) while simultaneously increasing the value of the delivered energy. Failures including molten-salt leaks and diverse localized cracking after several months to a few years of operation have been reported in hot tanks for CSP plants operating around the world. A model of a molten salt thermal energy storage tank was developed and validated to analyze the impact of different tank design features on the temperature and stress distributions as a function of typical plant operation conditions. Design features included the floor plate thicknesses, friction coefficients between the tank floor and the foundation, and the sparger ring location. Maximum stresses in the tank floor frequently surpassed the yield point of the material during operation, leading to a detriment of the tank's lifetime. Recommendations on design features to improve the reliability of new molten salt tanks for CSP plants are provided.

concentrating solar power↗