Search NASA⌕ Search

SEARCH · Search NASA

Results for “collimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23

TH-AB-BRA-01: A Novel Doubly-Focused Multileaf Collimator Design for MR-Guided Radiation Therapy

Purpose: To describe the physical and dosimetric properties of a novel double-stack multileaf collimator (MLC). Methods: One of the compromises made in the MLC design has been to employ linear-motion singly-divergent shapes. Because the MLC leading edge moves linearly, it is rounded to provide a consistent, albeit compromised penumbra. The MLC employed in the new linac-based MR-IGRT unit is designed to be doubly focused in that each leaf moves in an arc centered at the source, and the sides of the leaves are machined such that they lie parallel to a line between the leaf edge and the source. The curvature of the MLC keeps motors and encoders in lower magnetic field. However, high spatial-resolution leaves are difficult to manufacture to sufficiently tight tolerances and difficult to move due to restricted space on the gantry. Wider leaves alleviate this problem with less moving parts but the coarse resolution disallows treating very small lesions. This compromise has been overcome by splitting the MLC leaf bank into two sets, stacked one upon the other and offset half of a leaf width. The dosimetry has been simulated using Monte-Carlo and a 6 MV linac in a 0.35 T magnetic field. Results: The combined MLC leaf set has a spatial resolution of effectively half of the leaf width, 4mm here. The dosimetry resolution and conformality are consistent with 4mm wide MLC assisted by inverse fluence modulation. Also, because each leaf junction is backed up by the stacked leaf that lies over the junction, the problem of tongue-and-groove dosimetry has been greatly reduced. The novel MLC design allows the use of more powerful leaf motors than would be otherwise possible if a single MLC bank is employed. Conclusions: The stacked MLC will provide highly conformal dose distributions suitable for stereotactic radiation therapy of small lesions. The research was funded by ViewRay, Inc.

60 APPLIED LIFE SCIENCES↗

Simulation Study of Hollow Electron Beam Collimation for LHC

In this note we describe the results of numerical simulations of hollow electron beam collimation for the nominal LHC machine. The halo cleaning rates for various operating scenarios are predicted. The impact of electron lens imperfections on the collider luminosity performance is estimated.

43 PARTICLE ACCELERATORS↗

Dose calculations using MARS for Bremsstrahlung beam stops and collimators in APS beamline stations.

The Monte Carlo radiation transport code MARS is used to model the generation of gas bremsstrahlung (GB) radiation from 7-GeV electrons which scatter from residual gas atoms in undulator straight sections within the Advanced Photon Source (APS) storage ring. Additionally, MARS is employed to model the interactions of the GB radiation with components along the x-ray beamlines and then determine the expected radiation dose-rates that result. In this manner, MARS can be used to assess the adequacy of existing shielding or the specifications for new shielding when required. The GB radiation generated in the 'thin-target' of an ID straight section will consist only of photons in a 1/E-distribution up to the full energy of the stored electron beam. Using this analytical model, the predicted GB power for a typical APS 15.38-m insertion device (ID) straight section is 4.59 x 10{sup -7} W/nTorr/mA, assuming a background gas composed of air (Z{sub eff} = 7.31) at room temperature (293K). The total GB power provides a useful benchmark for comparisons between analytical and numerical approaches. We find good agreement between MARS and analytical estimates for total GB power. The extended straight section 'target' creates a radial profile of GB, which is highly peaked centered on the electron beam. The GB distribution reflects the size of the electron beam that creates the radiation. Optimizing the performance of MARS in terms of CPU time per incident trajectory requires the use of a relatively short, high-density gas target (air); in this report, the target density is {rho}L = 2.89 x 10{sup -2} g/cm{sup 2} over a length of 24 cm. MARS results are compared with the contact dose levels reported in TB-20, which used EGS4 for radiation transport simulations. Maximum dose-rates in 1 cc of tissue phantom form the initial basis for comparison. MARS and EGS4 results are approximately the same for maximum 1-cc dose-rates and attenuation in the photon-dominated regions; for thicker targets, however, the dose-rate no longer depends only on photon attenuation, as photoneutrons (PNs) begin to dominate. The GB radiation-induced photoneutron measurements from four different metals (Fe, Cu, W, and Pb) are compared with MARS predictions. The simulated dose-rates for beamline 6-ID are approximately 3-5 times larger than the measured values, whereas those for beamline 11-ID are much closer. Given the uncertainty in local values of pressure and Z, the degree of agreement between MARS and the PN measurements is good. MARS simulations of GB-induced radiation in and around the FOE show the importance of using actual pressure and gas composition (Z{sub eff}) to obtain accurate PN dose. For a beam current of 300 mA, extrapolating pressure data measured in previously published studies predicts an average background gas pressure of 27 nTorr. An average atomic number of Z{sub eff} = 4.0 is obtained from the same studies. In addition, models of copper masks presently in use at the APS are included. Simulations show that inclusion of exit masks make significant differences in both the radiation spatial distribution within the FOE, as well as the peak intensity. Two studies have been conducted with MARS to assess shielding requirements. First, dose levels in contact with the outside wall of the FOE are examined when GB radiation strikes Pb or W beam stops of varying transverse size within the FOE. Four separate phantom regions are utilized to measure the dose, two at beam elevation and two at the horizontal beam position. The first two phantoms are used for scoring FOE dose along the outside and back walls, horizontally; the second two collect dose on the roof and vertically on the back wall. In all cases, the beam stop depth is maintained at 30 cm. Inclusion of front end (FE) exit masks typically cause a 1-2 order-of-magnitude increase in the dose-rates relative to the case with no masks. Masks place secondary bremsstrahlung sources inside the FOE, and therefore they must be shielded appropriately. The MARS model does not fully account for all shielding present in the hutches; localized shielding is employed in individual hutches. Typically, a collimator, placed downstream of the FE exit masks, mitigates the possible increase in dose. Regarding beam stop transverse size, a modest reduction in dose on the back wall is noted as the stop dimension (square cross section) is increased from 12 cm to 24 cm. In the second study, the thickness of Pb required to shield against the GB extremal ray is determined. In this study, we are interested in finding the thickness of material necessary to add at the edge of a stop to adequately block GB radiation; therefore, we look at the case of no masks in order to have a well-defined GB beam edge. Simulations show the separation between the extremal ray and the edge of the shielding should be 2R{sub m}, where R{sub m} is the Moliere radius.

43 PARTICLE ACCELERATORS↗

Fabricating Sub-collimating Grids for an X-ray Solar Imaging Spectrometer using LIGA Techniques

This paper describes fabrication of sub-collimating X-ray grids that are used in an instrument for the High Energy Solar Spectroscopic Imager ( HESSI ), a proposed NASA mission that will promote understanding of solar particle acceleration and explosive energy release in the magnetized plasmas at the Sun. The HESSI comprises 12 rotating pairs of high-aspect-ratio, high-Z grids; each pair is separated by 1.7 meters and backed by a single Ge detector.

x-ray↗

Fabricating Sub-Collimating Grids for an X-Ray Solar Imaging Spectrometer Using LIGA Techniques

A proposed NASA mission uses a High Energy Solar Spectroscopic Imager (HESSI) to image solar X-rays. The HESSI instrument consists of twelve rotating pairs of high aspect ratio, high Z grids, each pair of which is separated by 1.7 meters and backed by a single Ge detector. Discussed are the fabrication of these proof-of-concept sub-collimating X-ray grids which are to be used in HESSI.

solar↗

RADBALLTECHNOLOGY TESTING AND MCNP MODELING OF THE TUNGSTEN COLLIMATOR

The United Kingdom's National Nuclear Laboratory (NNL) has developed a remote, non-electrical, radiation-mapping device known as RadBall{trademark}, which can locate and quantify radioactive hazards within contaminated areas of the nuclear industry. RadBall{trademark} consists of a colander-like outer shell that houses a radiation-sensitive polymer sphere. The outer shell works to collimate radiation sources and those areas of the polymer sphere that are exposed react, becoming increasingly more opaque, in proportion to the absorbed dose. The polymer sphere is imaged in an optical-CT scanner, which produces a high resolution 3D map of optical attenuation coefficients. Subsequent analysis of the optical attenuation matrix provides information on the spatial distribution of sources in a given area forming a 3D characterization of the area of interest. RadBall{trademark} has no power requirements and can be positioned in tight or hard-to reach locations. The RadBall{trademark} technology has been deployed in a number of technology trials in nuclear waste reprocessing plants at Sellafield in the United Kingdom and facilities of the Savannah River National Laboratory (SRNL). This study focuses on the RadBall{trademark} testing and modeling accomplished at SRNL.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Search for light long-lived neutral particles that decay to collimated pairs of leptons or light hadrons in $pp$ collisions at $\sqrt{s}$ = 13 TeV with the ATLAS detector

A search for light long-lived neutral particles with masses in the O(MeV–GeV) range is presented. The analysis targets the production of long-lived dark photons in the decay of a Higgs boson produced via gluon–gluon fusion or in association with a W boson. Events that contain displaced collimated Standard Model fermions reconstructed in the calorimeter or muon spectrometer are selected in 139 fb -1 of $\sqrt{s}$ = 13 TeV $pp$ collision data collected by the ATLAS detector at the LHC. Background estimates for contributions from Standard Model processes and instrumental effects are extracted from data. The observed event yields are consistent with the expected background. Exclusion limits are reported on the production cross-section times branching fraction as a function of the mean proper decay length cτ of the dark photon, or as a function of the dark-photon mass and kinetic mixing parameter that quantifies the coupling between the Standard Model and potential hidden (dark) sectors. A Higgs boson branching fraction above 1% is excluded at 95% CL for a Higgs boson decaying into two dark photons for dark-photon mean proper decay lengths between 10 mm and 250 mm and dark photons with masses between 0.4 GeV and 2 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Effect of Collimating Lens Focusing on Laser Beam Shape in Matrix Assisted Laser Desorption/Ionization Mass Spectrometry (MALDI-MS)

Tissue imaging using matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) is a well-established technique that, in recent years, has seen wider adoption and novel application. Applications such imaging mass spectrometry (IMS) and biotyping are beginning to gain greater exposure and use; however, with limitations in optimization methods, producing the best result often relies on the ability to customize the physical characteristics of the instrumentation, a task that is challenging for most mass spectrometry laboratories. With this in mind, we have described the effect of making simple adjustments to the laser optics at the final collimating lens area, to adjust the laser beam size and shape in order to allow greater customization of the instrument for improving techniques such as IMS. We have therefore been able to demonstrate that improvements can be made without requiring the help of an electrical engineer or external funding in a way that only costs a small amount of time. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image-Based Dynamic Multileaf Collimator Tracking of Moving Targets During Intensity-Modulated Arc Therapy

Purpose: Intensity-modulated arc therapy (IMAT) enables efficient and highly conformal dose delivery. However, intrafraction motion may compromise the delivered target dose distribution. Dynamic multileaf collimator (DMLC) tracking can potentially mitigate the impact of target motion on the dose. The purpose of this study was to use a single kV imager for DMLC tracking during IMAT and to investigate the ability of this tracking to maintain the dose distribution. Methods: A motion phantom carrying a two-dimensional (2D) ion chamber array and buildup material with an embedded gold marker reproduced eight representative tumor trajectories (four lung tumors, four prostate). For each trajectory, a low and high IMAT plan were delivered with and without DMLC tracking. The three-dimensional (3D) real-time target position signal for tracking was provided by fluoroscopic kV images acquired immediately before and during treatment. For each image, the 3D position of the embedded marker was estimated from the imaged 2D position by a probability-based method. The MLC leaves were continuously refitted to the estimated 3D position. For lung, prediction was used to compensate for the tracking latency. The delivered 2D dose distributions were measured with the ion chamber array and compared with a reference dose distribution delivered without target motion using a 3%/3 mm {gamma}-test. Results: For lung tumor motion, tracking reduced the mean {gamma}-failure rate from 38% to 0.7% for low-modulation IMAT plans and from 44% to 2.8% for high-modulation plans. For prostate, the {gamma}-failure rate reduction was from 19% to 0% (low modulation) and from 20% to 2.7% (high modulation). The dominant contributor to the residual {gamma}-failures during tracking was target localization errors for most lung cases and leaf fitting errors for most prostate cases. Conclusion: Image-based tracking for IMAT was demonstrated for the first time. The tracking greatly improved the dose distributions to moving targets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proton-Nucleus Scattering Approximations and Implications for LHC Crystal Collimation

In particle accelerators, scattered protons with energies close to the incident particles may travel considerable distances with the beam before impacting on accelerator components downstream. To analyze such problems, angular deflection and energy loss of scattered particles are the main quantities to be simulated since these lead to changes in the beam's phase space distribution and particle loss. Simple approximations for nuclear scattering processes causing limited energy loss to high-energy protons traversing matter are developed which are suitable for rapid estimates and reduced-description Monte Carlo simulations. The implications for proton loss in the Large Hadron Collider due to nuclear scattering on collimation crystals are discussed.

43 PARTICLE ACCELERATORS↗

Stable laser-acceleration of high-flux proton beams with plasma collimation

Laser-plasma acceleration of protons offers a compact, ultra-fast alternative to conventional ac- celeration techniques, and is being widely pursued for potential applications in medicine, industry and fundamental science. Creating a stable, collimated beam of protons at high repetition rates presents a key challenge. Here, we demonstrate the generation of multi-MeV proton beams from a fast-replenishing ambient-temperature liquid sheet. The beam has an unprecedentedly low diver- gence of 1◦ (≤ 20 mrad), resulting from magnetic self-guiding of the proton beam during propagation through a low density vapour. The proton beams, generated at a repetition rate of 5 Hz using only 190 mJ of laser energy, exhibit a hundred-fold increase in flux compared to beams from a solid target. Coupled with the high shot-to-shot stability of this source, this represents a crucial step towards applications.

Glenn, G. D. [SLAC National Accelerator Laboratory↗

Acceleration of collimated 45 MeV protons by collisionless shocks driven in low-density, large-scale gradient plasmas by a 10 20 W/cm 2 , 1 µm laser

A new type of proton acceleration stemming from large-scale gradients, low-density targets, irradiated by an intense near-infrared laser is observed. The produced protons are characterized by high-energies (with a broad spectrum), are emitted in a very directional manner, and the process is associated to relaxed laser (no need for high-contrast) and target (no need for ultra-thin or expensive targets) constraints. As such, this process appears quite efective compared to the standard and commonly used Target Normal Sheath Acceleration technique (TNSA), or more exploratory mechanisms like Radiation Pressure Acceleration (RPA). The data are underpinned by 3D numerical simulations which suggest that in these conditions a Low Density Collisionless Shock Acceleration (LDCSA) mechanism is at play, which combines an initial Collisionless Shock Acceleration (CSA) to a boost procured by a TNSA-like sheath feld in the downward density ramp of the target, leading to an overall broad spectrum. Experiments performed at a laser intensity of 10 20 W/cm 2 show that LDCSA can accelerate, from ~1% critical density, mm-scale targets, up to 5×109 protons/MeV/sr/J with energies up to 45(±5) MeV in a collimated (~6° half-angle) manner.

43 PARTICLE ACCELERATORS↗

Superior spatial resolution in confocal X-ray techniques using collimating channel array optics: elemental mapping and speciation in archaeological human bone

Confocal X-ray fluorescence imaging (CXFI) and confocal X-ray absorption spectroscopy (CXAS) respectively enable the study of three dimensionally resolved localization and speciation of elements. Applied to a thick sample, essentially any volume element of interest within the X-ray fluorescence escape depth can be examined without the need for physical thin sectioning. To date, X-ray confocal detection generally has employed a polycapillary optic in front of the detector to collect fluorescence from the probe volume formed at the intersection of its focus with the incident microfocus beam. This work demonstrates the capability of a novel Collimating Channel Array (CCA) optic in providing an improved and essentially energy independent depth resolution approaching 2 μm. By presenting a comparison of elemental maps of archaeological bone collected without confocal detection, and with polycapillary- and CCA-based confocal detection, this study highlights the strengths and limitations of each mode. Unlike the polycapillary, the CCA shows similar spatial resolution in maps for both low (Ca) and high (Pb and Sr) energy X-ray fluorescence, thus illustrating the energy independent nature of the CCA optic resolution. While superior spatial resolution is demonstrated for all of these elements, the most significant improvement is observed for Ca, demonstrating the advantage of employing the CCA optic in examining light elements. In addition to CXFI, this configuration also enables the collection of Pb L3 CXAS data from micro-volumes with dimensions comparable to bone microstructures of interest. Our CXAS result, which represents the first CCA-based biological CXAS, demonstrates the ability of CCA optics to collect site specific spectroscopic information. The demonstrated combination of site-specific elemental localization and speciation data will be useful in diverse fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Collimated GeV electrons from the ionization of a gas by a laser pulse in an intense magnetic field

A scheme is proposed for the acceleration of electrons generated during ionization of the helium and nitrogen gases by a laser pulse in the presence of an intense magnetic field. The electrons generated from the low atomic number gases gain energy in GeV due to the resonance between the electrons and the electric field of the laser in the presence of magnetic field. It is shown that collimated GeV electrons with small energy spread can be obtained from the ionization of helium and nitrogen. Suitable parameters have also been found for the suggested scheme.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compact collimated fiber optic array diagnostic for railgun plasmas

We developed and tested a compact collimated 16 channel fiber optic array diagnostic for studying the light emission of railgun armature plasmas with approximately millimeter spatial and submicrosecond temporal resolution. The design and operational details of the diagnostic are described. Plasma velocities, oscillation, and dimension data from the diagnostic for the Livermore fixed hybrid armature experiment are presented and compared with one-dimensional simulations. The techniques and principles discussed allow the extension of the diagnostic to other railgun and related dense plasma experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Density effects on collimation of energetic electron beams driven by two intense laser pulses

When an intense laser pulse irradiates solid targets, the light energy is deposited at the relativistic critical density and relativistic electrons are produced. However, these fast electrons are generally divergent. In this paper, a scheme to reduce the divergence of laser-driven energetic electron beams in solid-density plasmas is investigated by two-dimensional particle-in-cell simulation. In the scheme, two intense laser pulses and a plasma target consisting of two parts with different densities are employed. The first laser pulse induces a strong interface magnetic field by generating fast electron flow along the density interface. The magnetic field collimates the electrons generated by the second laser pulse. The simulation results show that the strong interface magnetic field can change the direction of the energetic beam electrons and considerably reduce their divergence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion Beam Collimation For Improved Resolution In Associated Particle Imaging

Beam spot size on target for a Penning ion source has been measured under different source operating pressures as a function of the extraction channel length and beam energy. A beam halo/core structure was observed for ion extraction at low extraction voltages, and was greatly reduced at higher beam energy. Collimation through use of longer extraction channels results in reduced ion current on target; the resultant reduction in neutron yield for an API system driven by such an ion source can be compensated for by use of even higher beam energies.

43 PARTICLE ACCELERATORS↗